4 Couple rs 126

Housing Design I with System Powe r Supply Dimensions (mm) 51 x 65 x 100 W x H x L (Height from upper edge of the DIN-rail) Wire connection CAGE CLAMP ® Cross sections 0.08 mm² ... 2.5 mm² / 28 ... 14 AWG Strip lengths 8 ... 9 mm / 0.33 in.

Housing Design II with System Powe r Supply Dimensions (mm) 62 x 65 x 100 W x H x L (Height from upper edge of the DIN-rail)

Housing Design without System Powe r Supply Dimensions (mm) 50 x 65 x 97 W x H x L (Height from upper edge of the DIN-rail) Wire connection CAGE CLAMP ® Cross sections 0.08 mm² ... 1.5 mm² / 28 ... 14 AWG Strip lengths 5 ... 6 mm / 0.22 in.

Housing Design ECO Dimensions (mm) 50 x 65 x 97 W x H x L (Height from upper edge of the DIN-rail) Wire connection CAGE CLAMP ® Cross sections 0.08 mm² ... 1.5 mm² / 28 ... 16 AWG Strip lengths 5 ... 6 mm / 0.22 in. Modula r I/O- System Ove rview 4 r Fieldbus Couple s 127

Housing Design without System with System Power Supply Power Supply ECO

Fi eldbus System Desc ription Item No. Page

Fieldbus Couple r, 100 Mbit 750-340 128

Fieldbus Couple r, 2-port, 100 Mbit 750-370 130

Fieldbus Couple r, advanced, 2-port 750-375 132 Fieldbus Couple r, advanced, 2-port, extended operating temperature range: -20 °C ... +60 °C 750-375/025-000 132 Fieldbus Couple r, advanced, ECO, 2-port 750-377 134 Fieldbus Couple r, advanced, ECO, 2-port, extended operating temperature range: -20 °C ... +60 °C 750-377/025-000 134 DP/FM S Fieldbus Couple r, 12 Mbaud 750-303 136

DP/V1 Fieldbus Couple r, 12 Mbaud 750-333 138 DP/V1 Fieldbus Couple r, 12 Mbaud, extended operating temperature range: -20 °C ... +60 °C 750-333/025-000 138 DP/ECO Fieldbus Couple r, 12 Mbaud 750-343 140

Fieldbus Couple r with Fibe r Optic Plug, 1.5 Mbaud 750-331 142

Fieldbus Couple r, 10/100 Mbit 750-352 144 MODBU S/TCP

S MODBU /TCP Fieldbus Couple r, 10 Mbit 750-342 146

Fieldbus Couple r, 100 Mbit/s 750-354 148

Fieldbus Couple r, ID- Switch, 100 Mbit/s 750-354/000-001 150

Fieldbus Couple r 750-306 152

ECO Fieldbus Couple r 750-346 154 4.1

Fieldbus Couple r 750-307 156 FC Fieldbus Couple r 750-337 158 Fieldbus Couple r, extended operating temperature range: -20 °C ... +60 °C 750-337/025-000 158 Fieldbus Couple r, D-Sub 750-338 160

ECO Fieldbus Couple r 750-347 162

ECO Fieldbus Couple r, D-Sub 750-348 164

Fieldbus Couple r, 2-port., 100 Mbit 750-351 166

Fieldbus Couple r, RS-485 (150 ... 115.2 kbaud) 750-315/300-000 168 MODBU S Fieldbus Couple r, RS-232 (150 ... 115.2 kbaud) 750-316/300-000 170

Fieldbus Couple r, 500 kbaud 750-304 172

ECO Fieldbus Couple r, 500 kbaud 750-344 174

ECO Fieldbus Couple r, 2 Mbaud 750-345 176

Fieldbus Couple r with Fibe r Optic Plug 750-334 178

Fieldbus Couple r 750-310 180 750-340 4 PROFINET IO Fieldbus Coupler 128 10/100 Mbit/s; digital and analog signals

PROFINET IO 01 02 Status A voltage supply LINK C B -System Fieldbus MS D -Power jumper contacts connection NS 24V 0V Data contacts RJ-45 TxD/RxD Supply 24 V 0 V I/O + + Supply via power jumper contacts 24 V

— — 750-340

W 0 V

Configuration interface Power jumper contacts

This fieldbus coupler connects the WAGO-I/O-SYSTEM as a slave to the PROFINET IO standard for automation. The fieldbus coupler supports all WAGO-I/O-SYSTEM modules.

The coupler automatically configures, creating a local process image which may include analog, digital, or specialty modules. Analog and specialty module data is sent via words and/or bytes; digital data is sent bit by bit.

The fieldbus coupler is integrated into the application as a PROFINET IO device.

Pack. Item No. Description Unit System Data PROFINET IO 100 MBit 750-340 1 No. of couplers connected to Master limited by PROFINET specification Transmission medium Twisted Pair S-UTP 100 Ω cat. 5 Max. length of fieldbus segment 100 m between hub station and 750-340; max. length of network limited by PROFINET specification Baud rate 10/100 Mbit/s Buscoupler connection RJ-45 Protocols PROFINET RT V2.0 Pack. (RT Class 1); Accessories Item No. Unit Conformance Class A (DCP, UDP); Miniature WSB Quick marking system HTTP plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Korea Certification r UL 508 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 129

24 V 1 5 DC I/O 24 V /0 V 10 nF DC modules 0 V 2 6 24 V

24 V S FACE ELECT RONIC S R FIELDBU INTE

FACE 3 7 R

S 0 V 0 V INTE 10 nF S ONIC R

4 8 FIELDBU ELECT

750-340

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C with bus extension 128 Wire connection CAGE CLAMP ® Max. input process image 320 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Max. output process image 320 bytes Strip lengths 8 ... 9 mm / 0.33 in Configuration via PC Dimensions (mm) W x H x L 51 x 65 x 100 Power supply 24 V DC (-15 % ... +20 %) Height from upper-edge of DIN 35 rail Max. input current (24 V) 500 mA Weight 179.5 g Power supply efficiency 87 % Storage temperature -25 °C ... +85 °C Internal current consumption (5 V) 300 mA Relative air humidity (no condensation) 95 % Total current for I/O modules (5 V) 1700 mA Vibration resistance acc. to IEC 60068-2-6 Isolation 500 V system/supply Shock resistance acc. to IEC 60068-2-27 Voltage via power jumper contacts 24 V DC (-15 % ... +20 %) Degree of protection IP20 Current via power jumper contacts (max.) 10 A DC EMC immunity of interference acc. to EN 61000-6-2 4.1 EMC emission of interference acc. to EN 61000-6-4 750-370 4 PROFINET IO Fieldbus Coupler 130 2-port; 100 Mbit/s; digital and analog signals

PROFINET IO 01 02 Status A voltage supply LINK C ACT1 B -System Fieldbus Link D -Power jumper contacts connection ACT2 RJ-45 BF 24V 0V Data contacts DIA Supply 24 V Fieldbus 0 V I/O connection + + RJ-45 Supply via power jumper contacts 24 V

— — 750-370 W 8 7 6 5 4 3 2 1 ON 0 V

Dip switch

Configuration interface Power jumper contacts

This fieldbus coupler connects to the WAGO-I/O-SYSTEM as a slave of the PROFINET IO, the open Industrial ETHERNET standard for automation. The fieldbus coupler supports all I/O modules. The buscoupler automatically configures, creating a local process image which may include analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes; digital data is sent bit by bit. This buscoupler can integrate into the application as a PROFINET IO device. The buscoupler features an integrated 2-port switch, allowing easy line structure creation without requiring any additional network components. The device name can be assigned via DCP protocol or be adjusted by a DIP switch if the protocol is not supported by the control systems.

Pack. Item No. Description Unit System Data PROFINET IO 100 MBit 2-port 750-370 1 No. of couplers connected to Master limited by PROFINET specification Transmission medium Twisted Pair S-UTP 100 Ω cat. 5 Max. length of fieldbus segment 100 m between switch and 750-370; max. length of network limited by PROFINET specification Baud rate 10/100 Mbit/s Buscoupler connection 2 x RJ-45 Protocols PROFINET IO Pack. (RT Class 1); Accessories Item No. Unit Conformance Class B (DCP, SNMP, LLDP); Miniature WSB Quick marking system HTTP plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Korea Certification r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 131

24 V 1 5 DC I/O 10 nF 24 V /0 V DC modules 0 V 2 6 24 V

24 V S FACE

ELECT RONIC S R FIELDBU INTE

FACE 3 7 R

S 0 V 0 V INTE 10 nF S ONIC R

4 8 FIELDBU ELECT

750-370

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C with bus extension 128 Wire connection CAGE CLAMP ® Max. input process image 320 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Max. output process image 320 bytes Strip lengths 8 ... 9 mm / 0.33 in Configuration via PC Dimensions (mm) W x H x L 51 x 65 x 100 Power supply 24 V DC (-15 % ... +20 %) Height from upper-edge of DIN 35 rail Max. input current (24 V) 500 mA Weight 189.5 g Power supply efficiency 87 % Storage temperature -25 °C ... +85 °C Internal current consumption (5 V) 300 mA Relative air humidity (no condensation) 95 % Total current for I/O modules (5 V) 1700 mA Vibration resistance acc. to IEC 60068-2-6 Isolation 500 V system/supply Shock resistance acc. to IEC 60068-2-27 Voltage via power jumper contacts 24 V DC (-15 % ... +20 %) Degree of protection IP20 Current via power jumper contacts (max.) 10 A DC EMC immunity of interference acc. to EN 61000-6-2 4.1 EMC emission of interference acc. to EN 61000-6-3 750-375 4 PROFINET IO advanced Fielbus Coupler 132 2-port switch; 100 Mbit/s; digital, analog and complex signals

Ma rking a rea 8 01 02 Status voltage supply Add ress PROFINET IO R A UN C -System B ON D -Power jumer contacts Data contacts BF 24V 0V ON 1 12345678 DIA Supply 8=OFF:DCP 24 V I/O 0 V W + +

® Supply via power jumper contacts 24 V 750-375

Fieldbus RO F I N E T connection P — — RJ-45 X 1 0 V Fieldbus ACT connection RJ-45 X 2 ACT LNK LNK Configuration and Power jumper contacts programming interface (with cover open)

The 750-375 Fieldbus Coupler connects the WAGO-I/O-SYSTEM 750 to PROFINET IO (open, real-time industrial ETHERNET automation standard). The coupler identifies the connected I/O modules and creates local process images for maximum two IO controllers and one IO supervisor according to preset configurations. The process images may include a mixed arrangement of analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes; digital data is sent bit by bit. The fieldbus coupler operates as an IO device in the network. It features an integrated 2-port switch, simplifying the creation of a line structure without additional network components. The device name can be assigned via DCP protocol or set via DIP switch.

Pack. Item No. Description Unit System Data PROFINET IO adv. 2-Port 750-375 1 No. of couplers connected to Master limited by PROFINET specification PROFINET IO adv. 2-Port/T 750-375/025-000 1 Transmission medium Twisted Pair S-UTP 100 Ω cat. 5 Extended temperature range: -20 °C ... +60 °C Max. length of fieldbus segment 100 m between hub station and 750-375; max. length of network limited by PROFINET specification Baud rate 10 Mbit/s (ETHERNET protocols), 100 Mbit/s full duplex (PROFINET IO) Transmission method 100Base-TX Pack. Buscoupler connection 2 x RJ-45 Accessories Item No. Unit PROFINET IO standard V2.2 (conformance class C, pending) Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Marine applications (versions upon request) GL r UL 508 4 133

24 V

1 5 DC I/O 24 V /0 V 10 nF modules DC 0 V

2 6 24 V

24 V S

R S FACE ELECT ONIC R FIELDBU INTE FACE 3 7 R 0 V S 0 V 10 nF INTE S ONIC R

4 8 ELECT FIELDBU

750-375

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C with bus extension 250 Wire connection CAGE CLAMP ® Max. input process image 512 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Max. output process image 512 bytes Strip lengths 8 ... 9 mm / 0.33 in Configuration via PC Dimensions (mm) W x H x L 62 x 65 x 100 PROFINET IO features Integrated 2-port switch; Height from upper-edge of DIN 35 rail Auto-negotiation, Auto-MDIX; Weight 150.3 g Isochronous real-time communication Storage temperature -25 °C ... +85 °C (pending); Relative air humidity (no condensation) 95 % Transmission clock: 1 ms (RT), Vibration resistance acc. to IEC 60068-2-6 1, 2, 4 ms (IRT); Shock resistance acc. to IEC 60068-2-27 Device replacement without programming Degree of protection IP20 tool; Shared device EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 Protocols Topology detection / LLDP, EMC emission of interference acc. to EN 61000-6-3, marine applications Network diagnostics / SNMP / MIB-2, media redundancy / MRP (pending), Web server / HTTP Profiles supported PROFIsafe V2, PROFIenergy V1.0 ID code Vendor ID: 0x011D; Device ID: 0x02EE; Coupler ID: 0x01000177 Power supply 24 V DC (-25 % ... +30 %) Input current typ. at rated load (24 V) 500 mA Efficiency of the power supply (typ.) at nominal load (24 V) 90 % Internal current consumption (5 V) 450 mA Total current for I/O modules (5 V) 1700 mA Isolation 500 V system/supply 750-377 4 PROFINET IO advanced ECO Fielbus Coupler 134 2-port switch; 100 Mbit/s; digital, analog and complex signals

Ma rking a rea 8 Add ress PROFINET IO RUN Status indication ON -Fieldbus BF -Fieldbus note ON 1 12345678 DIA Data contacts 8=OFF:DCP I/O W

Supply ® 24 V 24V 0 V X3

0V 750-377 RO F I N E T P Fieldbus connection X RJ-45 1 ACT

Fieldbus connection X Configuration and RJ-45 2 programming interface

ACT LNK LNK (with cover open)

The 750-377 Fieldbus Coupler connects the WAGO-I/O-SYSTEM 750 to PROFINET IO (open, real-time industrial ETHERNET automation standard). The coupler identifies the connected I/O modules and creates local process images for one IO controller and one IO supervisor according to preset configurations. The process images may include a mixed arrangement of analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes; digital data is sent bit by bit. The fieldbus coupler operates as an IO device in the network. It features an integrated 2-port switch, simplifying the creation of a line structure without additional network components. The device name can be assigned via DCP protocol or set via DIP switch.

Pack. Item No. Description Unit System Data PROFINET IO adv. ECO 2-Port 750-377 1 No. of couplers connected to Master limited by PROFINET specification PROFINET IO adv. ECO 2-Port/T 750-377/025-000 1 Transmission medium Twisted Pair S-UTP 100 Ω cat. 5 Extended temperature range: -20 °C ... +60 °C Max. length of fieldbus segment 100 m between hub station and 750-377; max. length of network limited by PROFINET specification Baud rate 10 Mbit/s (ETHERNET protocols), 100 Mbit/s full duplex (PROFINET IO) Transmission method 100Base-TX Pack. Buscoupler connection 2 x RJ-45 Accessories Item No. Unit PROFINET IO standard V2.2 (conformance class C, pending) Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Marine applications (versions upon request) GL r UL 508 4 135

24 V 24 V 0 V DC I/O 10 nF modules DC 0 V S

R S FACE ELECT ONIC R FIELDBU INTE FACE R S 10 nF INTE S ONIC R ELECT FIELDBU

750-377

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 256 bytes Wire connection CAGE CLAMP ® Max. output process image 256 bytes Cross sections 0.08 mm² ... 1.5 mm² / AWG 28 ... 14 Configuration via PC Strip lengths 5 ... 6 mm / 0.22 in PROFINET IO features Integrated 2-port switch; Dimensions (mm) W x H x L 50 x 65 x 97 Auto-negotiation, Auto-MDIX; Height from upper-edge of DIN 35 rail Isochronous real-time communication Weight 107.1 g (pending); Storage temperature -25 °C ... +85 °C Transmission clock: 1 ms (RT), Relative air humidity (no condensation) 95 % 1, 2, 4 ms (IRT); Vibration resistance acc. to IEC 60068-2-6 Device replacement without programming Shock resistance acc. to IEC 60068-2-27 tool Degree of protection IP20 Protocols Topology detection / LLDP, EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 Network diagnostics / SNMP / MIB-2, EMC emission of interference acc. to EN 61000-6-3, marine applications media redundancy / MRP (pending), Web server / HTTP Profiles supported PROFIsafe V2, PROFIenergy V1.0 ID code Vendor ID: 0x011D; Device ID: 0x02EE; Coupler ID: 0x01000179 Power supply 24 V DC (-25 % ... +30 %) Input current typ. at rated load (24 V) 280 mA Efficiency of the power supply (typ.) at nominal load (24 V) 90 % Internal current consumption (5 V) 450 mA Total current for I/O modules (5 V) 700 mA Isolation 500 V system/supply 750-303 4 DP/FMS Fieldbus Coupler 136 12 Mbaud; digital and analog signals

PROFIBUS 01 02 Status

A voltage supply RUN C -Power jumper contacts B BF D -System DIA 24V 0V Data Contacts Fieldbus Supply connection 24 V D-Sub 0 V I/O RUN + + I/O ERR Supply via power jumper contacts 24 V ADDRESS x1 — — 0 1

9 2

8 3

Address 7 4 303 750- 5 5 6 6

W 0 V

01

9 2

8 3

4 7 7

5 5 Address 6

Configuration Power jumper contacts interface

This buscoupler connects the WAGO-I/O-SYSTEM as a slave to the PROFIBUS The local process image is divided into two data zones containing the data fieldbus. received and the data to be sent. The process data can be sent via the PROFIBUS fieldbus to the PLC, PC or NC for further processing, and received The buscoupler automatically configures, creating a local process image which from the field via PROFIBUS. may include analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes, digital data is sent bit by bit. The data of the analog modules is stored in the process image which is created automatically according to the order in which the modules are connected to the PROFIBUS stores the process image in the corresponding Master control (PLC, buscoupler. The bits of the digital modules are sent byte by byte and added to PC or NC). the analog data. If the amount of digital information exceeds 8 bits, the buscoupler automatically starts with a new byte. When implementing new installations, please consider 750-333 PROFIBUS DP fieldbus coupler with extended functions. Notice: GSD files required!

Pack. Item No. Description Unit System Data PROFIBUS DP/FMS 12 MBd 750-303 1 No. of couplers connected to Master 96 with repeater Max. no. of I/O points approx. 6000 (depends on master) Transmission medium Cu cable acc. to EN 50170 Max. length of fieldbus segment 100 m ... 1200 m (depends on baud rate/cable) Baud rate 9.6 Kbaud ... 12 Mbaud Pack. Transmission time typ. 1 ms (10 couplers; 32 digital I/Os per Accessories Item No. Unit coupler at 12 Mbaud) max. 3.3 ms GSD files Download: www.wago.com Buscoupler connection 1 x D-Sub 9; socket Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Standards and Approvals

Standard EN 50170 Certification PNO Conformity marking 1 Korea Certification Marine applications ABS, BV, DNV, GL, KR, LR, NKK, PRS, RINA r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 137

I/O modules S

FACE 24 V R 1 5 24 V 5 V ELECT RONIC S FIELDBU INTE 24 V /0 V 10 nF 5 V 0 V 2 6 24 V 24 V

FIELDBU S INTE RFACE 3 7

S 0 V 0 V 10 nF ONIC R

4 8 ELECT

750-303

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 128 bytes Wire connection CAGE CLAMP ® Max. output process image 128 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 up version 05xx, max. 64 bytes Strip lengths 8 ... 9 mm / 0.33 in Configuration via PC or PLC Dimensions (mm) W x H x L 51 x 65 x 100 Power supply 24 V DC (-25 % ... +30 %) Height from upper-edge of DIN 35 rail Max. input current (24 V) 500 mA Weight 185.2 g Power supply efficiency 87 % Storage temperature -25 °C ... +85 °C Internal current consumption (5 V) 350 mA Relative air humidity (no condensation) 95 % Total current for I/O modules (5 V) 1650 mA Vibration resistance acc. to IEC 60068-2-6 Isolation 500 V system/supply Shock resistance acc. to IEC 60068-2-27 Voltage via power jumper contacts 24 V DC (-25 % ... +30 %) Degree of protection IP20 Current via power jumper contacts (max.) 10 A DC EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 EMC emission of interference acc. to EN 61000-6-4, marine applications 750-333 4 PROFIBUS DP/V1 Fieldbus Coupler 138 12 Mbaud; digital and analog signals

PROFIBUS 01 02 Status

A voltage supply RUN C -System B BF D -Power jumper contacts DIA 24V 0V Data Contacts BUS Fieldbus Supply connection 24 V D-Sub 0 V I/O + + Supply via power jumper contacts 24 V ADDRESS x1 — — 01

9 2

8 3

Address 7 4 750-333 5 5 6 6

W 0 V

x10 01

9 2

8 3

4 7 7

5 5 Address 6

Configuration interface Power jumper contacts

This buscoupler interfaces the I/O modules of the WAGO-I/O-SYSTEM to It is furthermore possible to deactive I/O modules and to modify the image of PROFIBUS DP. the node according to the connected signals without having to modify the existing application. When initializing, the buscoupler determines the module structure of the node, to create the process image in PROFIBUS. In order to optimize addresses, the The diagnosis concept is based on diagnostics according to the EN 50170 I/O modules with a bit width smaller than 8 are grouped in one byte. standard. Therefore the programming of modules is not necessary to interpret the diagnostic information from each manufacturer. Notice: GSD files required

Pack. Item No. Description Unit System Data PROFIBUS DP/V1 12MBd 750-333 1 No. of couplers connected to Master 96 with repeater PROFIBUS DP/V1/T 750-333/025-000 1 Max. no. of I/O points approx. 6000 (depends on master) Extended temperature range: -20 °C ... +60 °C Transmission medium Cu cable acc. to EN 50170 Max. length of fieldbus segment 100 m ... 1200 m (depends on baud rate/cable) Baud rate 9.6 Kbaud ... 12 Mbaud Pack. Transmission time typ. 1 ms (10 couplers; 32 digital I/Os Accessories Item No. Unit per coupler at 12 Mbaud) max. 3.3 ms GSD files Download: www.wago.com Buscoupler connection 1 x D-Sub 9; socket Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Standards and Approvals

Standard EN 50170 Conformity marking 1 Korea Certification Marine applications (versions upon request) ABS, BV, DNV, GL, KR, LR, NKK, PRS, RINA r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 TÜV 12.1297 X (Brasilien) Ex nA IIC T4 Gc 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 139

I/O modules S

FACE 24 V R 1 5 24 V ELECT RONIC S FIELDBU INTE 24 V /0 V 10 nF 5 V 5 V 0 V 2 6 24 V 24 V

FIELDBU S INTE RFACE 3 7

S 0 V 0 V 10 nF ONIC R

4 8 ELECT

750-333

Technical Data General Specifications

Number of I/O modules 63 Operating temperature 0 °C ... +55 °C Max. input process image 244 bytes Wire connection CAGE CLAMP ® Max. output process image 244 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Configuration via PC or PLC Strip lengths 8 ... 9 mm / 0.33 in Power supply 24 V DC (-25 % ... +30 %) Dimensions (mm) W x H x L 51 x 65 x 100 Max. input current (24 V) 500 mA Height from upper-edge of DIN 35 rail Power supply efficiency 87 % Weight 183.1 g Internal current consumption (5 V) 200 mA Storage temperature -25 °C ... +85 °C Total current for I/O modules (5 V) 1800 mA Relative air humidity (no condensation) 95 % Isolation 500 V system/supply Vibration resistance acc. to IEC 60068-2-6 Voltage via power jumper contacts 24 V DC (-25 % ... +30 %) Shock resistance acc. to IEC 60068-2-27 Current via power jumper contacts (max.) 10 A DC Degree of protection IP20 EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 EMC emission of interference acc. to EN 61000-6-4, marine applications 750-343 4 PROFIBUS DP ECO Fieldbus Coupler 140 12 Mbaud; digital and analog signals

PROFIBUS Status indication -Fieldbus RUN -Fieldbus note DIP switch BF Address DIA Data contacts ON 1 2 3 4 5 6 7 8 750- 343 343 750- BUS W I/O

01 02 03 04

Marking area

Fieldbus connection D-Sub

Supply Configuration 24 V interface 0 V

The ECO fieldbus coupler is designed for applications with a reduced scale It is furthermore possible to deactive I/O modules and to modify the image of I/O requirement. Using digital only process data or small amounts of analogs, the node according to the connected signals without having to modify the while retaining all of the choice that’s offered by the Series 750 I/O. existing application.

The coupler has an integrated supply terminal for the system voltage. The diagnosis concept is based on diagnostics according to the EN 50170 The field power jumper contacts are supplied via a separate supply module. standard. Therefore the programming of modules is not necessary to interpret the diagnostic information from each manufacturer. When initializing, the buscoupler determines the module structure of the node, to create the process image in PROFIBUS. In order to optimize addresses, the I/O modules with a bit width smaller than 8 are grouped in one byte. Notice: GSD files required

Pack. Item No. Description Unit System Data PROFIBUS DP ECO 12 MBd 750-343 1 No. of couplers connected to Master 125 with repeater Max. no. of I/O points approx. 6000 (depends on master) Transmission medium Cu cable acc. to EN 50170 Max. length of fieldbus segment 100 m ... 1200 m (depends on baud rate/cable) Baud rate 9.6 Kbaud ... 12 Mbaud Pack. Transmission time typ. 1 ms (10 couplers; 32 digital I/Os Accessories Item No. Unit per coupler at 12 Mbaud) max. 3.3 ms GSD files Download: www.wago.com Buscoupler connection 1 x D-Sub 9; socket Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Standards and Approvals

Standard EN 50170 Conformity marking 1 Korea Certification Marine applications ABS, BV, DNV, GL, KR, LR, NKK, PRS, RINA r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 TÜV 12.1297 X (Brasilien) Ex nA IIC T4 Gc 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 141

I/O modules 1/2 24 V 24 V 10 nF 5 V ELECT RONIC S 5 V 3/4 0 V S FACE S R ONIC FIELDBU INTE

R FIELDBU S INTE RFACE ELECT 10 nF 24 V 0 V

1 2 3 4

750-343

Technical Data General Specifications

Number of I/O modules 63 Operating temperature 0 °C ... +55 °C Max. input process image 32 bytes Wire connection CAGE CLAMP ® Max. output process image 32 bytes Cross sections 0.08 mm² ... 1.5 mm² / AWG 28 ... 16 Configuration via PC or PLC Strip lengths 5 ... 6 mm / 0.22 in Power supply 24 VDC (-25 % ... +30 %) Dimensions (mm) W x H x L 50 x 65 x 97 Input current typ. at rated load (24 V) 260 mA Height from upper-edge of DIN 35 rail Efficiency of the power supply (typ.) at Weight 110.4 g nominal load (24 V) 80 % Storage temperature -25 °C ... +85 °C Internal current consumption (5 V) 350 mA Relative air humidity (no condensation) 95 % Total current for I/O modules (5 V) 650 mA Vibration resistance acc. to IEC 60068-2-6 Shock resistance acc. to IEC 60068-2-27 Degree of protection IP20 EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 EMC emission of interference acc. to EN 61000-6-4, marine applications 750-331 4 PROFIBUS DP Fieldbus Coupler 142 1.5 Mbaud; digital and analog signals

01 Status

9 2 PROFIBUS-DP 01 02

8 3

4

Address x 1 7 A voltage supply 5 5 6 6 RUN C -Power jumper contacts B BF D -System 01

9 2

8 3 DIA Data contacts

4 Address x 10 7 24V 0V 5 5

6 Supply 24 V 0 V I/O RUN + + I/O ERR Supply via power jumper contacts 24 V

Signal — — input

Signal 750-331 output W 0 V

PE PE ON ON 1 1

Baud rate 2

Configuration interface Power jumper contacts

This buscoupler connects the WAGO-I/O-SYSTEM as a slave to the PROFIBUS The data of the analog modules is stored in the process image which is created DP fieldbus. automatically according to the order in which the modules are connected to the buscoupler. The bits of the digital modules are sent byte by byte and added to The buscoupler automatically configures, creating a local process image which the analog data. If the amount of digital information exceeds 8 bits, the may include analog, digital or specialty modules. Analog and specialty buscoupler automatically starts with a new byte. module data is sent via words and/or bytes, digital data is sent bit by bit. For the operation of a PROFIBUS DP coupler with fiber optic cable connection, The local process image is divided into two data zones containing the data an interface module is also necessary to transfer RS-485 on a fiber optic ring. received and the data to be sent. The process data can be sent via the A subring can contain up to 10 other fiber optic modules. The baud rate is set PROFIBUS DP fieldbus to the PLC, PC or NC for further processing, and via two DIP switches on the buscoupler. received from the field via PROFIBUS DP. Notice: GSD files required

Pack. Item No. Description Unit System Data PROFIBUS DP 1.5 MBd / Opt. Fiber 750-331 1 No. of couplers connected to Master 10 in the subring Transmission medium APF (plastic) fiber (1000µm) Max. length of fieldbus segment 1 m ... 25 m Topology Subring, single-fiber ring Baud rate 93.75 Kbaud ... 1500 Kbaud Buscoupler connection HP Simplex fiber optic plug (included)

Pack. Item No. Accessories Unit GSD files Download: www.wago.com Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Standards and Approvals

Standard EN 50170 Conformity marking 1 Korea Certification r UL 508 DEKRA 11 ATEX 0203 X II 3 G Ex nA II T4 4 143

24 V 1 5 DC I/O 24 V /0 V 10 nF DC modules 0 V 2 6 24 V 24 V ELECT RONIC S FIELDBU S

FACE INTE RFACE

R 3 7

S 0 V

INTE 0 V 10 nF S ONIC R

4 8 ELECT FIELDBU

750-331

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 128 bytes Wire connection CAGE CLAMP ® Max. output process image 128 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Configuration via PC or PLC Strip lengths 8 ... 9 mm / 0.33 in Power supply 24 V DC (-15 % ... +20 %) Dimensions (mm) W x H x L 51 x 65 x 100 Max. input current (24 V) 500 mA Height from upper-edge of DIN 35 rail Power supply efficiency 87 % Weight 187 g Internal current consumption (5 V) 350 mA Storage temperature -25 °C ... +85 °C Total current for I/O modules (5 V) 1650 mA Relative air humidity (no condensation) 95 % Isolation 500 V system/supply Vibration resistance acc. to IEC 60068-2-6 Voltage via power jumper contacts 24 V DC (-15 % ... +20 %) Shock resistance acc. to IEC 60068-2-27 Current via power jumper contacts (max.) 10 A DC Degree of protection IP20 EMC immunity of interference acc. to EN 61000-6-2 4.1 EMC emission of interference acc. to EN 61000-6-4

DIP Switches

Baud rate 93.75 kBd / S1 = off; S2 = off 187.5 kBd / S1 = off; S2 = on 500 kBd / S1 = on; S2 = off 1500 kBd / S1 = on; S2 = on 750-352 4 ETHERNET Fieldbus Coupler 144 10/100 Mbit/s; digital and analog signals

Ma rking a rea 8 Add ress ETHE RNET LINK 1 ACT Status indication ON LINK ACT 2 -Fieldbus MS -Fieldbus node ON 1 12345678 NS 0: WBM Data contacts 255: DHCP I/O W

Supply 24 V 24V 0 V X3

0V 750-352 Fieldbus connection RJ-45 X1

Fieldbus connection RJ-45 X2 Configuration and programming interface (with cover open)

The 750-352 ETHERNET Fieldbus Coupler connects ETHERNET to the modular The DIP switch configures the last byte of the IP address and may be used for WAGO-I/O-SYSTEM. IP address assignment (DHCP, BootP, static).

The fieldbus coupler automatically configures, creating a local process image The coupler is designed for fieldbus communication in both Ethernet/IP and which may include analog, digital or specialty modules. Analog and specialty networks. It also supports a wide variety of standard ETHERNET module data is sent via words and/or bytes; digital data is sent bit by bit. protocols (e.g., HTTP, BootP, DHCP, DNS, SNMP, FTP). An integrated Web server provides configuration and status information to the Two ETHERNET interfaces and an integrated switch allow the fieldbus to be coupler. wired in a line topology. This eliminates additional network devices such as switches or hubs. Both interfaces support Auto-Negotiation and Auto-MDI(X). The coupler has an integrated supply terminal for the system voltage. The field power jumper contacts are supplied via a separate supply module.

Pack. Item No. Description Unit System Data ETHERNET Coupler 750-352 1 No. of couplers connected to Master limited by ETHERNET specification Transmission medium Twisted Pair S-UTP 100 Ω, Cat 5; Max. line length: 100 m Baud rate 10/100 Mbit/s Transmission performance Class D acc. to EN 50173 Buscoupler connection 2 x RJ-45 Protocols EtherNet/IP, MODBUS/TCP (UDP), HTTP, Pack. BootP, DHCP, DNS, FTP, SNMP Item No. Accessories Unit Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Korea Certification Marine applications ABS, BV, DNV, GL, KR, LR, NKK, PRS, RINA r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 145

24 V 24 V 0 V DC I/O 10 nF modules DC 0 V S

R S FACE ELECT ONIC R FIELDBU INTE FACE R S 10 nF INTE S ONIC R ELECT FIELDBU

750-352

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C with bus extension 250 Wire connection CAGE CLAMP ® Max. input process image 1020 words Cross sections 0.08 mm² ... 1.5 mm² / AWG 28 ... 14 Max. output process image 1020 words Strip lengths 5 ... 6 mm / 0.22 in Configuration via PC Dimensions (mm) W x H x L 50 x 65 x 97 Power supply 24 V DC (-25 % ... +30 %) Height from upper-edge of DIN 35 rail Input current typ. at rated load (24 V) 280 mA Weight 112 g Efficiency of the power supply (typ.) at Storage temperature -25 °C ... +85 °C nominal load (24 V) 90 % Relative air humidity (no condensation) 95 % Internal current consumption (5 V) 450 mA Vibration resistance acc. to IEC 60068-2-6 Total current for I/O modules (5 V) 700 mA Shock resistance acc. to IEC 60068-2-27 Isolation 500 V system/supply Degree of protection IP20 EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 EMC emission of interference acc. to EN 61000-6-3, marine applications 750-342 4 ETHERNET TCP/IP Fieldbus Coupler 146 10 Mbit/s; digital and analog signals

ETHERNET 01 02 Status A voltage supply ON C B -System Fieldbus LINK D -Power jumper contacts connection RJ-45 TxD/RxD 24V 0V Data contacts ERROR Supply 24 V 0 V I/O + + Supply via power jumper contacts 24 V

— — 750-342

W 0 V

Configuration interface Power jumper contacts

The ETHERNET TCP/IP fieldbus coupler supports a number of network information on configuration, status, or I/O data of the ETHERNET TCP/IP protocols to send process data via ETHERNET TCP/IP. By observing the fieldbus coupler. Only a standard WEB browser is required. relevant IT standards, connection to existing local or global networks (LAN, Dynamic configuration of the IP addresses via a BootP server provides a flexible Internet) is possible without any problem. and easy way to configure the network. Using ETHERNET as a fieldbus makes universal data transmission between the factory and the office possible. Moreover, the ETHERNET TCP/IP fieldbus coupler offers remote maintenance, i.e. processes can be controlled regardless of the location. Process data exchange is done using the MODBUS/TCP protocol. The buscoupler supports all I/O modules and automatically configures, creating a local process image. The HTML pages that are stored in the fieldbus coupler allow access to

Pack. Item No. Description Unit System Data ETHERNET TCP/IP 10 MBit 750-342 1 No. of couplers connected to Master limited by ETHERNET specification Transmission medium Twisted Pair S-UTP 100 Ω cat. 5 Max. length of fieldbus segment 100 m between hub station and 750-342; max. length of network limited by ETHERNET specification Baud rate 10 Mbit/s Buscoupler connection RJ-45 Protocols MODBUS/TCP, HTTP, BootP, Pack. MODBUS/UDP Item No. Accessories Unit Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Korea Certification Marine applications ABS, BV, DNV, GL, KR, LR, NKK, PRS, RINA r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 TÜV 12.1297 X (Brasilien) Ex nA IIC T4 Gc 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 147

24 V 1 5 DC I/O 24 V /0 V 10 nF DC modules 0 V 2 6 24 V

24 V S FACE ELECT RONIC S R FIELDBU INTE FACE 3 7 R

S 0 V

INTE 0 V 10 nF S ONIC R

4 8 ELECT FIELDBU

750-342

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 512 bytes Wire connection CAGE CLAMP ® Max. output process image 512 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Max. number of socket connections 1 HTTP; 3 MODBUS/TCP Strip lengths 8 ... 9 mm / 0.33 in Power supply 24 V DC (-25 % ... +30 %) Dimensions (mm) W x H x L 51 x 65 x 100 Max. input current (24 V) 500 mA Height from upper-edge of DIN 35 rail Power supply efficiency 87 % Weight 197 g Internal current consumption (5 V) 200 mA Storage temperature -25 °C ... +85 °C Total current for I/O modules (5 V) 1800 mA Relative air humidity (no condensation) 95 % Isolation 500 V system/supply Vibration resistance acc. to IEC 60068-2-6 Voltage via power jumper contacts 24 V DC (-25 % ... +30 %) Shock resistance acc. to IEC 60068-2-27 Current via power jumper contacts (max.) 10 A DC Degree of protection IP20 EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 EMC emission of interference acc. to EN 61000-6-4, marine applications 750-354 4 EtherCAT Fieldbus Coupler 148 100 Mbit/s; digital and analog signals

Ma rking a rea

Ethe rCAT L/A IN Status indication L/A OUT -Fieldbus RUN -Fieldbus node ERR Data contacts I/O W

Supply 24 V 24V 0 V X3

0V 750-354 X Fieldbus 1 connection RJ-45 I N X Fieldbus 2 connection RJ-45 Configuration and O U programming interface T (with cover open)

The 750-354 EtherCAT Fieldbus Coupler connects EtherCAT to the modular EtherCAT ® (Ethernet Control Automation Technology) is a real-time ETHERNET WAGO-I/O-SYSTEM. solution designed for industrial automation applications and characterized by The fieldbus coupler automatically configures, creating a local process image high performance, flexible topology and simple configuration. With EtherCAT ®, which may include analog, digital or specialty modules. Analog and specialty the costly ETHERNET star topology can be replaced with a simple line or tree module data is sent via words and/or bytes; digital data is sent bit by bit. structure.

The “upper” EtherCAT interface connects the coupler to the network. The “lower” RJ-45 socket connects additional EtherCAT devices to the same line.

Pack. Item No. Description Unit System Data EtherCAT ® Coupler 750-354 1 No. of couplers connected to Master limited by EtherCAT specification Transmission medium Shielded twisted pair S/FTP, F/FTP or SF/FTP; 100 Ω, Cat 6 Baud rate 100 Mbit/s Transmission performance Class D acc. to EN 50173-1 Buscoupler connection 2 x RJ-45 Protocols EtherCAT (direct mode) Pack. Item No. Accessories Unit Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Korea Certification r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C EtherCAT ® is regristered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. 4 149

24 V 24 V 0 V DC I/O 10 nF modules DC 0 V S

R S FACE ELECT ONIC R FIELDBU INTE FACE R S 10 nF INTE S ONIC R ELECT FIELDBU

750-354

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 1024 bytes Wire connection CAGE CLAMP ® Max. output process image 1024 bytes Cross sections 0.08 mm² ... 1.5 mm² / AWG 28 ... 14 Configuration via PC Strip lengths 5 ... 6 mm / 0.22 in Power supply 24 V DC (-25 % ... +30 %) Dimensions (mm) W x H x L 65 x 50 x 97 Input current typ. at rated load (24 V) 250 mA Height from upper-edge of DIN 35 rail Efficiency of the power supply (typ.) at Weight 152 g nominal load (24 V) 85 % Storage temperature -25 °C ... +85 °C Internal current consumption (5 V) 300 mA Relative air humidity (no condensation) 95 % Total current for I/O modules (5 V) 700 mA Vibration resistance acc. to IEC 60068-2-6 Isolation 500 V system/supply Shock resistance acc. to IEC 60068-2-27 Degree of protection IP20 EMC immunity of interference acc. to EN 61000-6-2 4.1 EMC emission of interference acc. to EN 61000-6-3 750-354/000-001 4 EtherCAT ® Fieldbus Coupler, ID Switch 150 100 Mbit/s; digital and analog signals

Ma rking a rea 8 r ® Add ess Ethe rCAT L/A IN Status indication ON L/A OUT -Fieldbus RUN -Fieldbus node ON 1 12345678 ERR ID 1-255 Data contacts 0: off I/O W

Supply 24 V 24V 0 V X3 0V X Fieldbus 1 connection RJ-45 750-354/000-001 I N X Fieldbus 2 connection RJ-45 Configuration and O U programming interface T (with cover open)

The 750-354 EtherCAT ® Fieldbus Coupler connects EtherCAT ® to the modular EtherCAT ® (Ethernet Control Automation Technology) is a real-time ETHERNET WAGO-I/O-SYSTEM. solution designed for industrial automation applications and characterized by The fieldbus coupler automatically configures, creating a local process image high performance, flexible topology and simple configuration. With EtherCAT ®, which may include analog, digital or specialty modules. Analog and specialty the costly ETHERNET star topology can be replaced with a simple line or tree module data is sent via words and/or bytes; digital data is sent bit by bit. structure. The address selection switch is used to set an Explicit Device ID (EDI), which The upper EtherCAT ® interface connects the coupler to the network. The lower allows a fixed address to be assigned to an EtherCAT ® slave. RJ-45 socket connects additional EtherCAT ® devices to the same line.

Pack. Item No. Description Unit System Data EtherCAT ® Fieldbus Coupler, ID Switch 750-354/000-001 1 No. of couplers connected to Master limited by EtherCAT specification Transmission medium Shielded twisted pair S/FTP, F/FTP or SF/FTP; 100 Ω, Cat 6 Baud rate 100 Mbit/s Transmission performance Class D acc. to EN 50173-1 Buscoupler connection 2 x RJ-45 Protocols EtherCAT (direct mode) Pack. Item No. Accessories Unit Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Marine applications GL r UL 508

EtherCAT ® is regristered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. 4 151

24 V 24 V 0 V DC I/O 10 nF modules DC 0 V S

R S FACE ELECT ONIC R FIELDBU INTE FACE R S 10 nF INTE S ONIC R ELECT FIELDBU

750-354/000-001

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 1024 bytes Wire connection CAGE CLAMP ® Max. output process image 1024 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Configuration via PC Strip lengths 8 ... 9 mm / 0.33 in Power supply 24 V DC (-25 % ... +30 %) Dimensions (mm) W x H x L 65 x 50 x 97 Input current typ. at rated load (24 V) 250 mA Height from upper-edge of DIN 35 rail Efficiency of the power supply (typ.) at Weight 152 g nominal load (24 V) 85 % Storage temperature -25 °C ... +85 °C Internal current consumption (5 V) 300 mA Relative air humidity (no condensation) 95 % Total current for I/O modules (5 V) 700 mA Vibration resistance acc. to IEC 60068-2-6 Isolation 500 V system/supply Shock resistance acc. to IEC 60068-2-27 Degree of protection IP20 EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 EMC emission of interference acc. to EN 61000-6-3, marine applications 750-306 4 DeviceNet Fieldbus Coupler 152 125 ... 500 Kbaud; digital and analog signals

DeviceNet 01 02 Status A voltage supply OVERFL C MS B -System RUN D -Power jumper contacts Fieldbus BUS OFF 24V 0V Data contacts connection NS 231 Series (MCS) CONNECT Supply 24 V 0 V I/O + + Supply via power jumper contacts 24 V

— — 750-306 W 2 4 6 8 7 6 5 4 3 2 1 ON 0 V

DIP switch for MAC ID and baud rate

Configuration interface Power jumper contacts

This buscoupler connects the WAGO-I/O-SYSTEM as a slave to the The local process image is divided into two data zones containing the data Device Net TM fieldbus. received and the data to be sent. The process data can be sent via the Device Net TM fieldbus to the PLC, PC or NC for further processing, and received The buscoupler automatically configures, creating a local process image which from the field via Device Net TM . may include analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes, digital data is sent bit by bit. The data of the analog modules is stored in the process image which is created automatically according to the order in which the modules are connected to the Device Net TM stores the process image in the corresponding Master control buscoupler. The bits of the digital modules are sent byte by byte and added to (PLC, PC or NC). the analog data. If the amount of digital information exceeds 8 bits, the buscoupler automatically starts with a new byte. Notice: EDS files required

Pack. Item No. Description Unit System Data DeviceNet, w/ status byte 750-306 1 No. of couplers connected to Master 64 with scanner DeviceNet (only function with digital modules) 750-306/000-005 1 Max. no. of I/O points approx. 6000 (depends on master) DeviceNet (without buskoppler status byte) 750-306/000-006 1 Transmission medium Shielded Cu cable Trunk line: 2 x 0.82 mm² + 2 x 1.7 mm² Drop line: 2 x 0.2 mm² + 2 x 0.32 mm² Max. length of bus line 100 m ... 500 m (depends on baud rate/cable) Baud rate 125 Kbaud, 250 Kbaud, 500 Kbaud Pack. Buscoupler connection 5-pole male connector, 231 Series (MCS), Accessories Item No. Unit female connector 231-305/ 010-000/ EDS files Download: www.wago.com 050-000 (included) Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Certification ODVA Conformity marking 1 Korea Certification Marine applications (versions upon request) ABS, BV, DNV, GL, KR, LR, NKK, PRS, RINA r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 153

I/O modules 24 V 1 5 24 V ELECT RONIC S FI ELDBUS ELDBUS FI CE NTERFA I 24 V /0 V 10 nF 5 V 0 V 2 6 24 V 24 V

24 V FIELDBU S INTE RFACE 3 7 5 V 1) 2)

S 0 V 0 V 10 nF ONIC

R 1) 1 MΩ 4 8 2) 10 nF /500 V ELECT

750-306

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 512 bytes Wire connection CAGE CLAMP ® Max. output process image 512 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Configuration via PC or PLC Strip lengths 8 ... 9 mm / 0.33 in DeviceNet features Polled I/O message connection Dimensions (mm) W x H x L 51 x 65 x 100 Strobed I/O message connection Height from upper-edge of DIN 35 rail Change of state Weight 200 g Cyclic message connection Storage temperature -25 °C ... +85 °C Group 2 only, slave Relative air humidity (no condensation) 95 % Power supply 24 V DC (-25 % ... +30 %) Vibration resistance acc. to IEC 60068-2-6 Current consumption Shock resistance acc. to IEC 60068-2-27 via power supply terminal < 500 mA / 24 V Degree of protection IP20 via DeviceNet interface < 120 mA / 11 V EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 Power supply efficiency 87 % EMC emission of interference acc. to EN 61000-6-4, marine applications Internal current consumption (5 V) 350 mA Total current for I/O modules (5 V) 1650 mA Isolation 500 V system/supply Voltage via power jumper contacts 24 V DC (-25 % ... +30 %) Current via power jumper contacts (max.) 10 A DC 750-346 4 DeviceNet ECO Fieldbus Coupler 154 125 ... 500 Kbaud; digital and analog signals

DEVICENET Status indication OVERFL -Fieldbus DIP switch MS -Fieldbus note for MAC ID RUN and baud rate BUS OFF Data contacts ON ON 1 1 2 3 4 5 6 7 8 NS 750- 346 346 750- CONNECT W I/O

01 02 03 04

Marking area Fieldbus connection 231 Series (MCS)

Supply Configuration 24 V interface 0 V

The ECO fieldbus coupler is designed for applications with a reduced scale The local process image is divided into two data zones containing the data I/O requirement. Using digital only process data or small amounts of analogs, received and the data to be sent. The process data can be sent via the while retaining all of the choice that’s offered by the Series 750 I/O. Device Net TM fieldbus to the PLC, PC or NC for further processing, and received from the field via Device Net TM . The coupler has an integrated supply terminal for the system voltage. The field power jumper contacts are supplied via a separate supply module. The data of the analog modules is stored in the process image which is created automatically according to the order in which the modules are connected to the The Device Net TM buscoupler automatically configures, creating a local process buscoupler. The bits of the digital modules are sent byte by byte and added to image which may include analog, digital or specialty modules. the analog data. If the amount of digital information exceeds 8 bits, the Device Net TM stores the process image in the corresponding Master control buscoupler automatically starts with a new byte. (PLC, PC or NC). Notice: EDS files required

Pack. Item No. Description Unit System Data DeviceNet ECO 750-346 1 No. of couplers connected to Master 64 with scanner Max. no. of I/O points approx. 6000 (depends on master) Transmission medium Shielded Cu cable Trunk line: 2 x 0.82 mm² + 2 x 1.7 mm² Drop line: 2 x 0.2 mm² + 2 x 0.32 mm² Max. length of bus line 100 m ... 500 m (depends on baud rate/cable) Baud rate 125 Kbaud, 250 Kbaud, 500 Kbaud Pack. Buscoupler connection 5-pole male connector, 231 Series (MCS), Accessories Item No. Unit female connector 231-305/ 010-000/ EDS files Download: www.wago.com 050-000 (included) Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Korea Certification r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 TÜV 12.1297 X (Brasilien) Ex nA IIC T4 Gc 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 155

I/O modules 1/2 24 V 24 V 10 nF ELECT RONIC S 5 V 3/4 0 V S S FACE R ONIC FIELDBU INTE 24 V R FIELDBU S INTE RFACE 5 V 1) 2) ELECT 10 nF 24 V 0 V

1) 1 MΩ 2) 10 nF /500 V 1 2 3 4

750-346

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 32 bytes Wire connection CAGE CLAMP ® Max. output process image 32 bytes Cross sections 0.08 mm² ... 1.5 mm² / AWG 28 ... 14 Configuration via PC or PLC Strip lengths 5 ... 6 mm / 0.22 in Power supply 24 V DC (-15 % ... +20 %) Dimensions (mm) W x H x L 50 x 65 x 97 Current consumption Height from upper-edge of DIN 35 rail via power supply terminal (typ.) at Weight 115 g nominal load (24 V) 260 mA Storage temperature -25 °C ... +85 °C via DeviceNet interface < 120 mA / 11 V Relative air humidity (no condensation) 95 % Efficiency of the power supply (typ.) at Vibration resistance acc. to IEC 60068-2-6 nominal load (24 V) 80 % Shock resistance acc. to IEC 60068-2-27 Internal current consumption (5 V) 350 mA Degree of protection IP20 Total current for I/O modules (5 V) 650 mA EMC immunity of interference acc. to EN 61000-6-2 4.1 EMC emission of interference acc. to EN 61000-6-4 750-307 4 CANopen Fieldbus Coupler 156 10 Kbaud ... 1 Mbaud; digital and analog signals

CANopen 01 02 Status

A voltage supply CAN-ERR C -Power jumper contacts B RUN D -System Fieldbus TX 24V 0V Data contacts connection OVERFLOW 231 Series (MCS) RX Supply 24 V 0 V I/O RUN + + I/O ERR Supply via power jumper contacts 24 V

— — 750-307 W 2 4 6 8 7 6 5 4 3 2 1 ON 0 V

DIP switch PE PE for node ID and baud rate

Configuration interface Power jumper contacts

This buscoupler connects the WAGO-I/O-SYSTEM as a slave to the CANopen The data of the analog modules is stored in the PDOs according to the order in fieldbus. The module data is transmitted using PDOs and SDOs. which the modules are connected to the buscoupler. The bits of the digital modules are sent byte by byte and also mapped in the PDOs. If the amount of The buscoupler automatically configures, creating a local process image which digital information exceeds 8 bits, the buscoupler automatically starts with a may include analog, digital or specialty modules. Analog and specialty new byte. module data is sent via words and/or bytes, digital data is sent bit by bit. All entries of the object dictionary can be mapped - as the user likes - in the The local process image is divided into two data zones containing the data 5 Rx PDOs and 5 Tx PDOs. received and the data to be sent. The process data can be sent via the CANopen fieldbus to the PLC, PC or NC for further processing, and received The complete input and output process image can be transmitted using SDOs. from the field via CANopen. When implementing new installations, please consider 750-337 fieldbus coupler with extended functions. Notice: EDS files required!

Pack. Item No. Description Unit System Data CANopen 750-307 1 No. of couplers connected to Master 110 Transmission medium Shielded Cu cable 3 x 0.25 mm² Max. length of bus line 30 m ... 1000 m (depends on baud rate/cable) Baud rate 10 Kbaud ... 1 Mbaud Buscoupler connection 5-pole male connector, 231 Series (MCS), female connector 231-305/ 010-000 (included) Pack. Item No. Accessories Unit EDS files Download: www.wago.com Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Korea Certification r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 157

I/O modules 24 V 1 5 24 V 24 V /0 V 10 nF 5 V ELECT RONIC S 5 V 0 V 2 6 24 V 24 V

FIELDBU S R

FACE INTE FACE 3 7 1) 2) R

S 0 V

INTE 0 V 10 nF S ONIC

R 1) 1 MΩ 4 8 2) 10 nF /500 V ELECT FIELDBU

750-307

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 512 bytes Wire connection CAGE CLAMP ® Max. output process image 512 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Configuration via PC or PLC Strip lengths 8 ... 9 mm / 0.33 in No. of PDOs 5 Tx / 5 Rx Dimensions (mm) W x H x L 51 x 65 x 100 No. of SDOs 2 server SDOs Height from upper-edge of DIN 35 rail Communication profile DS-301 V3.0 Weight 200 g Device profile DS-401 V1.4 Storage temperature -25 °C ... +85 °C COB ID distribution SDO, standard Relative air humidity (no condensation) 95 % Node ID distribution DIP switches Vibration resistance acc. to IEC 60068-2-6 Other CANopen features NMT slave Shock resistance acc. to IEC 60068-2-27 Minimum boot-up Degree of protection IP20 Variable PDO mapping EMC immunity of interference acc. to EN 61000-6-2 4.1 Emergency message EMC emission of interference acc. to EN 61000-6-4 Life guarding Power supply 24 V DC (-15 % ... +20 %) Max. input current (24 V) 500 mA Power supply efficiency 87 % Internal current consumption (5 V) 350 mA Total current for I/O modules (5 V) 1650 mA Isolation 500 V system/supply Voltage via power jumper contacts 24 V DC (-15 % ... +20 %) Current via power jumper contacts (max.) 10 A DC 750-337 4 CANopen Fieldbus Coupler 158 10 Kbaud ... 1 Mbaud; digital and analog signals

CANopen 01 02 Status A voltage supply STOP C B -System RUN D -Power jumper contacts Fieldbus TX 24V 0V Data contacts conection OVERFLOW 231 Series (MCS) RX Supply 24 V 0 V I/O + + Supply via power jumper contacts 24 V

— — 750-337 W 2 4 6 8 7 6 5 4 3 2 1 ON 0 V

DIP switch for node ID and baud rate

Configuration interface Power jumper contacts

This buscoupler connects the WAGO-I/O-SYSTEM as a slave to the CANopen The data of the analog modules is stored in the PDOs according to the order in fieldbus. The module data is transmitted using PDOs and SDOs. which the modules are connected to the buscoupler. The bits of the digital modules are sent byte by byte and also mapped in the PDOs. If the amount of The buscoupler automatically configures, creating a local process image which digital information exceeds 8 bits, the buscoupler automatically starts with a may include analog, digital or specialty modules. Analog and specialty new byte. module data is sent via words and/or bytes, digital data is sent bit by bit. All entries of the object dictionary can be mapped - as the user likes - in the The local process image is divided into two data zones containing the data 32 Rx PDOs and 32 Tx PDOs. received and the data to be sent. The process data can be sent via the The complete input and output process image can be transmitted using SDOs. CANopen fieldbus to the PLC, PC or NC for further processing, and received "Spacer modules" can be set via software. from the field via CANopen. Notice: EDS files required

Pack. Item No. Description Unit System Data CANopen MCS 750-337 1 No. of couplers connected to Master 110 CANopen MCS/T 750-337/025-000 1 Transmission medium Shielded Cu cable 3 x 0.25 mm² Extended temperature range: -20 °C ... +60 °C Max. length of bus line 30 m ... 1000 m (depends on baud rate/cable) Baud rate 10 Kbaud ... 1 Mbaud Buscoupler connection 5-pole male connector, 231 Series (MCS), female connector 231-305/ 010-000 (included) Pack. Item No. Accessories Unit EDS files Download: www.wago.com Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Korea Certification Marine applications (versions upon request) ABS, BV, DNV, GL, KR, LR, NKK, PRS, RINA r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 TÜV 12.1297 X (Brasilien) Ex nA IIC T4 Gc 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 159

I/O modules S

FACE 24 V R 1 5 24 V 5 V ELECT RONIC S FIELDBU INTE 24 V /0 V 10 nF 5 V 0 V 2 6 24 V 24 V

FIELDBU S INTE RFACE 3 7 1) 2)

S 0 V 0 V 10 nF ONIC R 1) 1 MΩ 4 8 2) 10 nF /500 V ELECT

750-337

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 512 bytes Wire connection CAGE CLAMP ® Max. output process image 512 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Configuration via PC or PLC Strip lengths 8 ... 9 mm / 0.33 in No. of PDOs 32 Tx / 32 Rx Dimensions (mm) W x H x L 51 x 65 x 100 No. of SDOs 2 server SDOs Height from upper-edge of DIN 35 rail Communication profile DS-301 V4.1 Weight 220 g Device profile DS 401 V2.0 Storage temperature -25 °C ... +85 °C Marginal check Relative air humidity (no condensation) 95 % Edge-triggered PDOs Vibration resistance acc. to IEC 60068-2-6 Programmable error response Shock resistance acc. to IEC 60068-2-27 COB ID distribution SDO, standard Degree of protection IP20 Node ID distribution DIP switches EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 Other CANopen features NMT slave EMC emission of interference acc. to EN 61000-6-4, marine applications Minimum boot-up Variable PDO mapping Emergency message Life guarding Configuration of virtual modules Power supply 24 V DC (-25 % ... +30 %) Max. input current (24 V) 500 mA Power supply efficiency 87 % Internal current consumption (5 V) 350 mA Total current for I/O modules (5 V) 1650 mA Isolation 500 V system/supply Voltage via power jumper contacts 24 V DC (-25 % ... +30 %) Current via power jumper contacts (max.) 10 A DC 750-338 4 CANopen Fieldbus Coupler D-Sub 160 10 Kbaud ... 1 Mbaud; digital and analog signals

CANopen 01 02 Status A voltage supply STOP C B -System RUN D -Power jumper contacts TX 24V 0V Data contacts OVERFLOW RX Fieldbus Supply connection 24 V D-Sub 0 V I/O + + Supply via power jumper contacts 24 V

— — 750-338 W 2 4 6 8 7 6 5 4 3 2 1 ON 0 V

DIP switch for node ID and baud rate

Configuration interface Power jumper contacts

This buscoupler connects the WAGO I/O SYSTEM as a slave to the CANopen The process data can be sent via the CANopen fieldbus to the PLC, PC or NC fieldbus. for further processing, and received from the field via CANopen. The module data is transmitted using PDOs and SDOs. The data of the analog modules is stored in the PDOs according to the order in The buscoupler is capable of supporting all bus modules. The buscoupler which the modules are connected to the buscoupler. The bits of the digital mo- automatically configures, creating a local process image which may include dules are sent byte by byte and also mapped in the PDOs. If the amount of di- analog, digital or specialty modules. Analog and specialty module gital information exceeds 8 bits, the buscoupler automatically starts with a new data is sent via words and/or bytes, digital data is packed into bytes. byte. CANopen allows the storing of the process image in the corresponding Master All entries of the object dictionary can be mapped - as the user likes - in the 32 control (PLC, PC or NC). Rx PDOs and 32 Tx PDOs. The local process image is divided into two data zones containing the data The complete input and output process image can be transmitted using SDOs. received and the data to be sent. “Spacer modules“ can be set via software. Notice: EDS files required

Pack. Item No. Description Unit System Data CANopen D-Sub 750-338 1 No. of couplers connected to Master 110 Transmission medium Shielded Cu cable 3 x 0.25 mm² Max. length of bus line 30 m ... 1000 m (depends on baud rate/cable) Baud rate 10 Kbaud ... 1 Mbaud Buscoupler connection 1 x D-Sub 9; plug

Pack. Item No. Accessories Unit EDS files Download: www.wago.com Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Korea Certification Marine applications BV, GL, NKK, PRS, RINA r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 161

I/O modules S

FACE 24 V R 1 5 24 V 5 V ELECT RONIC S FIELDBU INTE 24 V /0 V 10 nF 5 V 0 V 2 6 24 V 24 V

FIELDBU S R 3 7 INTE FACE 1) 2)

S 0 V 0 V 10 nF ONIC R 1) 1 MΩ 4 8 2) 10 nF /500 V ELECT

750-338

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 512 bytes Wire connection CAGE CLAMP ® Max. output process image 512 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Configuration via PC or PLC Strip lengths 8 ... 9 mm / 0.33 in No. of PDOs 32 Tx / 32 Rx Dimensions (mm) W x H x L 51 x 65 x 100 No. of SDOs 2 server SDOs Height from upper-edge of DIN 35 rail Communication profile DS-301 V4.1 Weight 200 g Device profile DS 401 V2.0 Storage temperature -25 °C ... +85 °C Marginal check Relative air humidity (no condensation) 95 % Edge-triggered PDOs Vibration resistance acc. to IEC 60068-2-6 Programmable error response Shock resistance acc. to IEC 60068-2-27 COB ID distribution SDO, standard Degree of protection IP20 Node ID distribution DIP switches EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 Other CANopen features NMT slave EMC emission of interference acc. to EN 61000-6-4, marine applications Minimum boot-up Variable PDO mapping Emergency message Life guarding Configuration of virtual modules Power supply 24 V DC (-25 % ... +30 %) Max. input current (24 V) 500 mA Power supply efficiency 87 % Internal current consumption (5 V) 350 mA Total current for I/O modules (5 V) 1650 mA Isolation 500 V system/supply Voltage via power jumper contacts 24 V DC (-25 % ... +30 %) Current via power jumper contacts (max.) 10 A DC 750-347 4 CANopen ECO Fieldbus Coupler MCS 162 10 Kbaud ... 1 Mbaud; digital and analog signals

CANopen Status indication -Fieldbus STOP DIP switch -Fieldbus note for node ID RUN and baud rate TX Data contacts ON ON 1 2 3 4 5 6 7 8 OVERFL 750- 347 347 750- RX W I/O

01 02 03 04

Marking area Fieldbus connection 231 Series (MCS)

Supply Configuration 24 V interface 0 V

The ECO fieldbus coupler is designed for applications with a reduced scale The data of the analog modules is stored in the PDOs according to the order in I/O requirement. Using digital only process data or small amounts of analogs, which the modules are connected to the buscoupler. The bits of the digital mo- while retaining all of the choice that’s offered by the Series 750 I/O. dules are sent byte by byte and also mapped in the PDOs. If the amount of di- The coupler has an integrated supply terminal for the system voltage. The field gital information exceeds 8 bits, the buscoupler automatically starts with a new power jumper contacts are supplied via a separate supply module. byte. The CANopen bus coupler is capable of supporting all I/O modules and au- tomatically configures, creating a local process image. All entries of the object dictionary can be mapped - as the user likes - in the The local process image is divided into two data zones containing the data re- 5 Rx PDOs and 5 Tx PDOs. ceived and the data to be sent. The process data can be sent via the CANopen fieldbus to the PLC, PC or NC for further processing, and received from the field The complete input and output process image can be transmitted using SDOs. via CANopen. “Spacer modules“ can be set via software. Notice: EDS files required

Pack. Item No. Description Unit System Data CANopen ECO MCS 750-347 1 No. of couplers connected to Master 110 Transmission medium Shielded Cu cable 3 x 0.25 mm² Max. length of bus line 30 m ... 1000 m (depends on baud rate/cable) Baud rate 10 Kbaud ... 1 Mbaud Buscoupler connection 5-pole male connector, 231 Series (MCS), female connector 231-305/ 010-000 (included) Pack. Item No. Accessories Unit EDS files Download: www.wago.com Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Korea Certification Marine applications ABS, BV, DNV, GL, KR, LR, NKK, PRS, RINA r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 TÜV 12.1297 X (Brasilien) Ex nA IIC T4 Gc 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 163

I/O modules 1/2 24 V 24 V 10 nF 5 V ELECT RONIC S 5 V 3/4 0 V S S FACE R ONIC FIELDBU INTE S

R FIELDBU INTE RFACE 1) 2) ELECT 10 nF 24 V 0 V

1) 1 MΩ 2) 10 nF /500 V 1 2 3 4

750-347

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 32 bytes Wire connection CAGE CLAMP ® Max. output process image 32 bytes Cross sections 0.08 mm² ... 1.5 mm² / AWG 28 ... 16 Configuration via PC or PLC Strip lengths 5 ... 6 mm / 0.22 in No. of PDOs 5 Tx / 5 Rx Dimensions (mm) W x H x L 50 x 65 x 97 No. of SDOs 1 server SDO Height from upper-edge of DIN 35 rail Communication profile DS-301 V4.1 Weight 135 g Device profile DS-401 V2.0 Storage temperature -25 °C ... +85 °C Programmable error response Relative air humidity (no condensation) 95 % COB ID distribution SDO, standard Vibration resistance acc. to IEC 60068-2-6 Node ID distribution DIP switches Shock resistance acc. to IEC 60068-2-27 Other CANopen features NMT slave Degree of protection IP20 Minimum boot-up EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 Variable PDO mapping EMC emission of interference acc. to EN 61000-6-4, marine applications Emergency message Life guarding Power supply 24 VDC (-25 % ... +30 %) Input current typ. at rated load (24 V) 260 mA Efficiency of the power supply (typ.) at nominal load (24 V) 80 % Internal current consumption (5 V) 350 mA Total current for I/O modules (5 V) 650 mA 750-348 4 CANopen ECO Fieldbus Coupler D-Sub 164 10 Kbaud ... 1 Mbaud; digital and analog signals

CANopen Status indication -Fieldbus STOP DIP switch -Fieldbus note for node ID RUN and baud rate TX Data contacts ON ON 1 2 3 4 5 6 7 8 OVERFL 750- 348 348 750- RX W I/O

01 02 03 04

Marking area

Fieldbus connection D-Sub

Supply Configuration 24 V interface 0 V

The ECO fieldbus coupler is designed for applications with a reduced scale The data of the analog modules is stored in the PDOs according to the order in I/O requirement. Using digital only process data or small amounts of analogs, which the modules are connected to the buscoupler. The bits of the digital while retaining all of the choice that’s offered by the Series 750 I/O. modules are sent byte by byte and also mapped in the PDOs. If the amount of The coupler has an integrated supply terminal for the system voltage. The field digital information exceeds 8 bits, the buscoupler automatically starts with a power jumper contacts are supplied via a separate supply module. new byte. The CANopen bus coupler is capable of supporting all I/O modules and automatically configures, creating a local process image. All entries of the object dictionary can be mapped - as the user likes - in the The local process image is divided into two data zones containing the data 5 Rx PDOs and 5 Tx PDOs. received and the data to be sent. The process data can be sent via the CANopen fieldbus to the PLC, PC or NC for further processing, and received The complete input and output process image can be transmitted using SDOs. from the field via CANopen. “Spacer modules“ can be set via software. Notice: EDS files required

Pack. Item No. Description Unit System Data CANopen ECO D-Sub 750-348 1 No. of couplers connected to Master 110 Transmission medium Shielded Cu cable 3 x 0.25 mm² Max. length of bus line 30 m ... 1000 m (depends on baud rate/cable) Baud rate 10 Kbaud ... 1 Mbaud Buscoupler connection 1 x D-Sub 9; plug

Pack. Item No. Accessories Unit EDS files Download: www.wago.com Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Korea Certification Marine applications ABS, BV, DNV, GL, KR, LR, NKK, PRS, RINA r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 TÜV 12.1297 X (Brasilien) Ex nA IIC T4 Gc 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 165

I/O modules 1/2 24 V 24 V 10 nF 5 V ELECT RONIC S 5 V 3/4 0 V S S FACE R ONIC FIELDBU INTE S

R FIELDBU INTE RFACE 1) 2) ELECT 10 nF 24 V 0 V

1) 1 MΩ 2) 10 nF /500 V 1 2 3 4

750-348

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 32 bytes Wire connection CAGE CLAMP ® Max. output process image 32 bytes Cross sections 0.08 mm² ... 1.5 mm² / AWG 28 ... 16 Configuration via PC or PLC Strip lengths 5 ... 6 mm / 0.22 in No. of PDOs 5 Tx / 5 Rx Dimensions (mm) W x H x L 50 x 65 x 97 No. of SDOs 1 server SDO Height from upper-edge of DIN 35 rail Communication profile DS-301 V4.1 Weight 115 g Device profile DS-401 V2.0 Storage temperature -25 °C ... +85 °C Programmable error response Relative air humidity (no condensation) 95 % COB ID distribution SDO, standard Vibration resistance acc. to IEC 60068-2-6 Node ID distribution DIP switches Shock resistance acc. to IEC 60068-2-27 Other CANopen features NMT slave Degree of protection IP20 Minimum boot-up EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 Variable PDO mapping EMC emission of interference acc. to EN 61000-6-4, marine applications Emergency message Life guarding Power supply 24 V DC (-25 % ... +30 %) Input current typ. at rated load (24 V) 260 mA Efficiency of the power supply (typ.) at nominal load (24 V) 80 % Internal current consumption (5 V) 350 mA Total current for I/O modules (5 V) 650 mA 750-351 4 SERCOS Fieldbus Coupler 166 2-port; 100 Mbit/s; digital and analog signals

SERCOS III 01 02 Status A voltage supply LINK C Fieldbus B -System connection MS D -Power jumer contacts RJ-45 Data contacts S3 24V 0V TxD/RxD Supply 24 V Fieldbus 0 V connection I/O RJ-45 + + USR Supply via power jumper contacts 24 V

— — 750-351

W 0 V

Address ON 12345678

Configuration interface Power jumper contacts

The 750-351 Fielbus Coupler connects the WAGO-I/O-SYSTEM to the Two integrated ports allow easy creation of a line or ring structure without SERCOS network. requiring additional components. The ports support Auto-MDI/MDIX and will The fieldbus coupler is capable of supporting all WAGO I/O modules. The automatically detect the data direction so interchanging cables on the coupler buscoupler automatically configures, creating a local process image which will not impact operation. may include analog, digital or specialty modules. Analog and specialty The SERCOS node ID is assigned directly via network configuration. module data is sent via words and/or bytes; digital data is sent bit by bit. The buscoupler can integrate into the application as a SERCOS I/O device and supports the SERCOS service channel (SVC), real-time channel (RTC) and TCP/IP communication standard.

Pack. Item No. Description Unit System Data SERCOS Coupler 750-351 1 Number of couplers (slaves) in Sercos ring 512 Transmission medium Twisted Pair S-UTP 100 Ω Cat. 5 Max. length of fieldbus segment 100 m, limited by ETHERNET specification Max. length of network 51.2 km, limited by ETHERNET specification Baud rate 100 Mbit/s, full duplex Pack. Buscoupler connection 2 x RJ-45 Accessories Item No. Unit Protocols SERCOS, FSP-IO, TCP/IP, FTP, HTTP, BootP, Miniature WSB Quick marking system DHCP, SNTP plain 248-501 5 Supported services SVC, RTC, CC, IP, ring break (GDP_Basic, with marking see Section 11 SCP_VarCFG, SCP_Sync)

Approvals

SERCOS version V1.1.1 IO profile V1.1.1 Conformity marking 1 Korea Certification Marine applications ABS, BV, DNV, GL, KR, LR, PRS, RINA r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 167

24 V 1 5 DC I/O 24 V /0 V 10 nF DC modules 0 V 2 6 24 V

24 V S FACE

ELECT RONIC S R FIELDBU INTE

FACE 3 7 R

S 0 V 0 V

I NTE 10 nF S ONIC R 4 8 ELECT FIELDBU

750-351

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C with bus extension 250 Wire connection CAGE CLAMP ® Max. input process image 2 Kbytes (RTC and SVC) Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Max. output process image 2 Kbytes (RTC and SVC) Strip lengths 8 ... 9 mm / 0.33 in Configuration Node configuration via: Dimensions (mm) W x H x L 51 x 65 x 100 WAGO ETHERNET settings, Height from upper-edge of DIN 35 rail Web-based management, Weight 210 g WAGO-I/O-CHECK, Storage temperature -25 °C ... +85 °C SERCOS Master (CP2 or higher), Relative air humidity (no condensation) 95 % address selector switch Vibration resistance acc. to IEC 60068-2-6 Power supply 24 V DC (-25 % ... +30 %) Shock resistance acc. to IEC 60068-2-27 Max. input current (24 V) 500 mA Degree of protection IP20 Power supply efficiency 87 % EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 Internal current consumption (5 V) 300 mA EMC emission of interference acc. to EN 61000-6-4, marine applications Total current for I/O modules (5 V) 1700 mA Isolation 500 V system/supply Voltage via power jumper contacts 24 V DC (-25 % ... +30 %) Current via power jumper contacts (max.) 10 A DC 750-315/300-000 4 MODBUS Fieldbus Coupler 168 RS-485; 150 baud ... 115.2 Kbaud; digital and analog signals

Modbus 01 02 Status voltage supply ON A C -System B -Power jumper contacts TxD D RxD 24V 0V Data contacts CRC Supply Fieldbus 24 V connection 0 V D-Sub I/O + + Supply via power jumper contacts 24 V ADDRESS x1 — — F012 E 3

D 4

5

C

6

Address B

7 A 8 9 W 0 V 750-315/300-000

x10 F012 E 3

D 4

5

C

6

Address B 7 A 8 9

Configuration interface Power jumper contacts

This buscoupler connects the WAGO-I/O-SYSTEM as a slave to the MODBUS fieldbus.

The buscoupler automatically configures, creating a local process image which may include analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes, digital data is sent bit by bit.

The data of the analog modules is stored in the process image, which is created automatically according to the order in which the modules are connected to the buscoupler. The bits of the digital modules are sent byte by byte and added to the analog data. If the amount of digital information exceeds 8 bits, the buscoupler automatically starts with a new byte.

Pack. Item No. Description Unit System Data MODBUS / RS-485 / 150 Bd ... 115.2 kBd 750-315/300-000 1 No. of couplers connected to Master 247 with repeater Max. no. of I/O points approx. 6000 (depends on master) Transmission medium Shielded Cu cable 2 (4) x 0.25 mm² Max. length of fieldbus segment 1200 m (depends on baud rate/cable) Baud rate 150 baud ... 115.2 Kbaud Buscoupler connection 1 x D-Sub 9; socket

Pack. Item No. Accessories Unit Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Marine applications BV, DNV, GL, KR, NKK, PRS, RINA r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 169

I/O modules S

FACE 24 V R 1 5 24 V 10 nF 5 V ELECT RONIC S

FIELDBU INTE 24 V /0 V 5 V 0 V 2 6 24 V 24 V

FIELDBU S INTE RFACE 3 7

S 0 V 0 V 10 nF ONIC R

4 8 ELECT

750-315/300-000

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 512 bytes Wire connection CAGE CLAMP ® Max. output process image 512 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Configuration Via PC or rotary encoder switch Strip lengths 8 ... 9 mm / 0.33 in Power supply 24 V DC (-25 % ... +30 %) Dimensions (mm) W x H x L 51 x 65 x 100 Max. input current (24 V) 500 mA Height from upper-edge of DIN 35 rail Power supply efficiency 87 % Weight 183.2 g Internal current consumption (5 V) 350 mA Storage temperature -25 °C ... +85 °C Total current for I/O modules (5 V) 1650 mA Relative air humidity (no condensation) 95 % Isolation 500 V system/supply Vibration resistance acc. to IEC 60068-2-6 Voltage via power jumper contacts 24 V DC (-25 % ... +30 %) Shock resistance acc. to IEC 60068-2-27 Current via power jumper contacts (max.) 10 A DC Degree of protection IP20 EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 EMC emission of interference acc. to EN 61000-6-4, marine applications 750-316/300-000 4 MODBUS Fieldbus Coupler 170 RS-232; 150 baud ... 115.2 Kbaud; digital and analog signals

Modbus 01 02 Status voltage supply ON A C -System B -Power jumper contacts TxD D RxD 24V 0V Data contacts CRC Supply Fieldbus 24 V connection 0 V D-Sub I/O + + Supply via power jumper contacts 24 V ADDRESS x1 — — F012 E 3

D 4

5

C

6

Address B

7 A 8 9 W 0 V 750-316/300-000

x10 F012 E 3

D 4

5

C

6

Address B 7 A 8 9

Configuration interface Power jumper contacts

This buscoupler connects the WAGO-I/O-SYSTEM as a slave to the MODBUS fieldbus.

The buscoupler automatically configures, creating a local process image which may include analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes, digital data is sent bit by bit.

The data of the analog modules is stored in the process image, which is created automatically according to the order in which the modules are connected to the buscoupler. The bits of the digital modules are sent byte by byte and added to the analog data. If the amount of digital information exceeds eight bits, the buscoupler automatically starts with a new byte.

Pack. Item No. Description Unit System Data MODBUS / RS-232 / 150 Bd ... 115.2 kBd 750-316/300-000 1 No. of couplers connected to Master 247 with repeater Max. no. of I/O points approx. 6000 (depends on master) Transmission medium Shielded Cu cable 2 (4) x 0.25 mm² Max. length of fieldbus segment 1200 m (depends on baud rate/cable) Baud rate 150 baud ... 115.2 Kbaud Buscoupler connection 1 x D-Sub 9; socket

Pack. Item No. Accessories Unit Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Approvals

Conformity marking 1 Marine applications BV, DNV, GL, KR, NKK, PRS, RINA r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 171

I/O modules S

FACE 24 V R 1 5 24 V 10 nF 5 V ELECT RONIC S

FIELDBU INTE 24 V /0 V 5 V 0 V 2 6 24 V 24 V

FIELDBU S INTE RFACE 3 7

S 0 V 0 V 10 nF ONIC R

4 8 ELECT

750-316/300-000

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 512 bytes Wire connection CAGE CLAMP ® Max. output process image 512 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Configuration Via PC or rotary encoder switch Strip lengths 8 ... 9 mm / 0.33 in Power supply 24 V DC (-25 % ... +30 %) Dimensions (mm) W x H x L 51 x 65 x 100 Max. input current (24 V) 500 mA Height from upper-edge of DIN 35 rail Power supply efficiency 87 % Weight 184.8 g Internal current consumption (5 V) 350 mA Storage temperature -25 °C ... +85 °C Total current for I/O modules (5 V) 1650 mA Relative air humidity (no condensation) 95 % Isolation 500 V system/supply Vibration resistance acc. to IEC 60068-2-6 Voltage via power jumper contacts 24 V DC (-25 % ... +30 %) Shock resistance acc. to IEC 60068-2-27 Current via power jumper contacts (max.) 10 A DC Degree of protection IP20 EMC immunity of interference acc. to EN 61000-6-2, marine applications 4.1 EMC emission of interference acc. to EN 61000-6-4, marine applications 750-304 4 INTERBUS Fieldbus Coupler 172 500 Kbaud; digital and analog signals

INTERBUS 01 02 Status

A voltage supply READY C -System B Fieldbus BA D -Power jumper contacts connection D-Sub, RC 24V 0V Data contacts Input RD Supply 24 V 0 V I/O + + Supply via power jumper contacts 24 V

— — 750-304

W 0 V Fieldbus connection D-Sub, Output

Configuration interface Power jumper contacts

This buscoupler connects the WAGO-I/O-SYSTEM as a slave to the INTERBUS The local process image is divided into two data zones containing the data fieldbus. received and the data to be sent. The process data can be sent via the INTERBUS fieldbus to the PLC, PC or NC for further processing, and received The buscoupler automatically configures, creating a local process image which from the field via INTERBUS. The process data can be sent via the INTERBUS may include analog, digital or specialty modules. Analog and specialty fieldbus to the PLC, PC or NC for further processing, and received from the field module data is sent via words and/or bytes, digital data is sent bit by bit. via INTERBUS.

INTERBUS stores the process image in the corresponding Master control (PLC, The data of the analog modules is stored in the process image which is created PC or NC). automatically according to the order in which the modules are connected to the buscoupler. The bits of the digital modules are sent byte by byte and added to the analog data. If the amount of digital information exceeds 8 bits, the buscoupler automatically starts with a new byte.

Pack. Item No. Description Unit System Data INTERBUS 500 kBd 750-304 1 No. of couplers connected to Master 256 Max. no. of I/O points 4096 (depends on master) Transmission medium Certified Cu cable Max. length of fieldbus segment 400 m Baud rate 500 Kbaud Transmission time typ. 1.43 ms (10 couplers; 32 digital I/Os Buscoupler connection 1 x D-Sub 9; plug for input interface 1 x D-Sub 9; socket for output interface Pack. Item No. Accessories Unit INTERBUS files Download: www.wago.com Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Standards and Approvals

Standard EN 50254 Certification INTERBUS CLUB Conformity marking 1 Korea Certification r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 173

I/O modules S

FACE 24 V R 1 5 24 V 10 nF 5 V ELECT RONIC S

FIELDBU INTE 24 V /0 V 5 V 0 V 2 6 S S

FACE 24 V FIELDBU R 24 V INTE RFACE FIELDBU INTE

3 7 FIELDBU S 1) 2) R S 0 V INTE FACE 0 V 10 nF ONIC R 1) 15 nF 4 8 2) 1 M Ω ELECT

750-304

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 64 bytes Wire connection CAGE CLAMP ® Max. output process image 64 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Configuration via PC or PLC Strip lengths 8 ... 9 mm / 0.33 in Power supply 24 V DC (-15 % ... +20 %) Dimensions (mm) W x H x L 51 x 65 x 100 Max. input current (24 V) 500 mA Height from upper-edge of DIN 35 rail Power supply efficiency 87 % Weight 192 g Internal current consumption (5 V) 300 mA Storage temperature -25 °C ... +85 °C (as from version 0101), Relative air humidity (no condensation) 95 % 450 mA (previous versions) Vibration resistance acc. to IEC 60068-2-6 Total current for I/O modules (5 V) 1700 mA Shock resistance acc. to IEC 60068-2-27 (as from version 0101), Degree of protection IP20 1550 mA (previous versions) EMC immunity of interference acc. to EN 61000-6-2 4.1 Isolation 500 V system/supply EMC emission of interference acc. to EN 61000-6-4 Voltage via power jumper contacts 24 V DC (-15 % ... +20 %) Current via power jumper contacts (max.) 10 A DC 750-344 4 INTERBUS ECO Fieldbus Coupler 174 500 Kbaud; digital and analog signals

INTERBUS Status indication READY -Fieldbus -Fieldbus note Fieldbus BA connection D-Sub RC Data contacts Input 344 750- RD W I/O

01 02 03 04

Marking area Fieldbus connection D-Sub, Output

Supply Configuration 24 V interface 0 V

The ECO fieldbus coupler is designed for applications with a reduced scale The local process image is divided into two data zones containing the data I/O requirement. Using digital only process data or small amounts of analogs, received and the data to be sent. The process data can be sent via the while retaining all of the choice that’s offered by the Series 750 I/O. INTERBUS fieldbus to the PLC, PC or NC for further processing, and received from the field via INTERBUS. The coupler has an integrated supply terminal for the system voltage. The field power jumper contacts are supplied via a separate supply module. The data of the analog modules is stored in the process image which is created automatically according to the order in which the modules are connected to the The INTERBUS bus coupler automatically configures, creating a local process buscoupler. The bits of the digital modules are sent byte by byte and added to image which may include analog, digital or specialty modules. the analog data. If the amount of digital information exceeds 8 bits, the buscoupler automatically starts with a new byte. INTERBUS stores the process image in the corresponding Master control (PLC, PC or NC).

Pack. Item No. Description Unit System Data INTERBUS ECO 500 kBd 750-344 1 No. of couplers connected to Master 256 Max. no. of I/O points 4096 (depends on master) Transmission medium Certified Cu cable Max. length of fieldbus segment 400 m Baud rate 500 Kbaud Transmission time typ. 1.43 ms (10 couplers; 32 digital I/Os per coupler) Buscoupler connection 1 x D-Sub 9; plug for input interface Pack. 1 x D-Sub 9; socket for output interface Item No. Accessories Unit INTERBUS files Download: www.wago.com Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Standards and Approvals

Standard EN 50254 Conformity marking 1 Korea Certification r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 TÜV 12.1297 X (Brasilien) Ex nA IIC T4 Gc 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 175

I/O modules

S 1/2

FACE 24 V R 24 V 5 V ELECT RONIC S FIELDBU INTE 10 nF 5 V 3/4 0 V S S S

FACE FIELDBU

R INTE RFACE ONIC FIELDBU INTE R FIELDBU S 1) 2) INTE RFACE ELECT 10 nF 24 V 0 V

1) 15 nF 2) 1 MΩ 1 2 3 4

750-344

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 20 bytes Wire connection CAGE CLAMP ® Max. output process image 20 bytes Cross sections 0.08 mm² ... 1.5 mm² / AWG 28 ... 16 Configuration via PC or PLC Strip lengths 5 ... 6 mm / 0.22 in Power supply 24 V DC (-15 % ... +20 %) Dimensions (mm) W x H x L 50 x 65 x 97 Input current typ. at rated load (24 V) 260 mA Height from upper-edge of DIN 35 rail Efficiency of the power supply (typ.) at Weight 115 g nominal load (24 V) 80 % Storage temperature -25 °C ... +85 °C Internal current consumption (5 V) 350 mA Relative air humidity (no condensation) 95 % Total current for I/O modules (5 V) 650 mA Vibration resistance acc. to IEC 60068-2-6 Shock resistance acc. to IEC 60068-2-27 Degree of protection IP20 EMC immunity of interference acc. to EN 61000-6-2 4.1 EMC emission of interference acc. to EN 61000-6-4 750-345 4 INTERBUS ECO Fieldbus Coupler 176 2 Mbaud; digital and analog signals

INTERBUS Status indication -Fieldbus READY -Fieldbus note Fieldbus BA connection D-Sub RC Data contacts

Input 345 750- RD W I/O

01 02 03 04

Marking area Fieldbus connection D-Sub Output

Supply Configuration 24 V interface 0 V

This buscoupler connects the WAGO-I/O-SYSTEM as a slave to the INTERBUS The local process image is divided into two data zones containing the data fieldbus. received and the data to be sent. The process data can be sent via the INTERBUS fieldbus to the PLC, PC or NC for further processing, and received The buscoupler automatically configures, creating a local process image which from the field via INTERBUS. may include analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes, digital data is sent bit by bit. The data of the analog modules is stored in the process image which is created automatically according to the order in which the modules are connected to the INTERBUS stores the process image in the corresponding Master control (PLC, buscoupler. The bits of the digital modules are sent byte by byte and added to PC or NC). the analog data. If the amount of digital information exceeds 8 bits, the buscoupler automatically starts with a new byte.

Pack. Item No. Description Unit System Data INTERBUS ECO 2 MBd 750-345 1 No. of couplers connected to Master 256 Max. no. of I/O points 4096 (depends on master) Transmission medium Certified Cu cable Max. length of fieldbus segment 150 m Baud rate 2 Mbaud Transmission time on request Buscoupler connection 1 x D-Sub 9; plug for input interface 1 x D-Sub 9; socket for output interface Pack. Item No. Accessories Unit INTERBUS files Download: www.wago.com Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Standards and Approvals

Standard EN 50254 Conformity marking 1 Korea Certification r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 TÜV 12.1297 X (Brasilien) Ex nA IIC T4 Gc 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 177

I/O modules

S 1/2

FACE 24 V R 24 V 5 V ELECT RONIC S FIELDBU INTE 10 nF 5 V 3/4 0 V S

S S

FACE FIELDBU

R INTE RFACE ONIC FIELDBU INTE R

FIELDBU S 1) 2) INTE RFACE ELECT 10 nF 24 V 0 V

1) 15 nF 2) 1 MΩ 1 2 3 4

750-345

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 20 bytes Wire connection CAGE CLAMP ® Max. output process image 20 bytes Cross sections 0.08 mm² ... 1.5 mm² / AWG 28 ... 16 Configuration via PC or PLC Strip lengths 5 ... 6 mm / 0.22 in Power supply 24 V DC (-15 % ... +20 %) Dimensions (mm) W x H x L 50 x 65 x 97 Input current typ. at rated load (24 V) 260 mA Height from upper-edge of DIN 35 rail Efficiency of the power supply (typ.) at Weight 115 g nominal load (24 V) 80 % Storage temperature -25 °C ... +85 °C Internal current consumption (5 V) 350 mA Relative air humidity (no condensation) 95 % Total current for I/O modules (5 V) 650 mA Vibration resistance acc. to IEC 60068-2-6 Shock resistance acc. to IEC 60068-2-27 Degree of protection IP20 EMC immunity of interference acc. to EN 61000-6-2 4.1 EMC emission of interference acc. to EN 61000-6-4 750-334 4 INTERBUS Fieldbus Coupler 178 digital and analog signals; fiber optic

INTERBUS-S 01 02 Status voltage supply Signal A READY C -Power jumper contacts input B BA D -System Input RC 24V 0V Data contacts

Signal RD Supply autput 24 V 0 V I/O RUN + + OFF I/O ERR Fieldbus Supply via connection power jumper contacts fiber optic 24 V

ON — —

Signal 750-334 input W 0 V

Output PE PE

Signal output

Configuration interface Power jumper contacts

This buscoupler connects the WAGO-I/O-SYSTEM as a slave to the INTERBUS The data of the analog modules is stored in the process image which is created fieldbus. automatically according to the order in which the modules are connected to the buscoupler. The bits of the digital modules are sent byte by byte and added to The buscoupler automatically configures, creating a local process image which the analog data. If the amount of digital information exceeds 8 bits, the may include analog, digital or specialty modules. Analog and specialty modu- buscoupler automatically starts with a new byte. le data is sent via words and/or bytes, digital data is sent bit by bit. The fiber optic INTERBUS coupler can be put in any place on the ring. The local process image is divided into two data zones containing the data re- ceived and the data to be sent. The process data can be sent via the INTERBUS fieldbus to the PLC, PC or NC for further processing, and received from the field via INTERBUS.

Pack. Item No. Description Unit System Data INTERBUS 500 kBd / Opt. Fiber 750-334 1 No. of couplers connected to Master 256 Max. no. of I/O points 4096 (depends on master) Transmission medium APF (plastic) fiber (1000µm) Topology Ring, double fiber ring Max. length of fieldbus segment 1 m ... 40 m Baud rate 500 Kbaud Buscoupler connection F- SMA

Pack. Item No. Accessories Unit INTERBUS files Download: www.wago.com Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Standards and Approvals

Standard EN 50254 Certification INTERBUS CLUB Conformity marking 1 Korea Certification r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 TÜV 12.1297 X (Brasilien) Ex nA IIC T4 Gc DEKRA 11 ATEX 0203 X II 3 G Ex nA II T4 4 179

24 V 1 5 DC I/O 24 V /0 V 10 nF DC modules 0 V 2 6 24 V 24 V R S ELECT ONIC FIELDBU S INTE RFACE FACE 3 7 R

S 0 V

INTE 0 V 10 nF S ONIC R

4 8 FIELDBU ELECT

750-334

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Max. input process image 64 bytes Wire connection CAGE CLAMP ® Max. output process image 64 bytes Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Configuration via PC or PLC Strip lengths 8 ... 9 mm / 0.33 in Power supply 24 V DC (-15 % ... +20 %) Dimensions (mm) W x H x L 51 x 65 x 100 Max. input current (24 V) 500 mA Height from upper-edge of DIN 35 rail Power supply efficiency 87 % Weight 189.8 g Internal current consumption (5 V) 350 mA Storage temperature -25 °C ... +85 °C Total current for I/O modules (5 V) 1650 mA Relative air humidity (no condensation) 95 % Isolation 500 V system/supply Vibration resistance acc. to IEC 60068-2-6 Voltage via power jumper contacts 24 V DC (-15 % ... +20 %) Shock resistance acc. to IEC 60068-2-27 Current via power jumper contacts (max.) 10 A DC Degree of protection IP20 EMC immunity of interference acc. to EN 61000-6-2 4.1 EMC emission of interference acc. to EN 61000-6-4

Switch

OFF Fieldbus coupler is the last fieldbus device ON Output fieldbus interface is active 750-310 4 CC-Link Fieldbus Coupler 180 156 Kbaud ... 10 Mbaud; digital and analog signals

CC-Link 01 02 Status A voltage supply L RUN C B -System Fieldbus L ERR D -Power jumper contacts connection SD 24V 0V Data contacts D-Sub RD Supply 24 V 0 V I/O + + Supply via power jumper contacts 24 V 01

9 2

8 3

4 7 7 Baud rate — — 5 5

6 750- 310 750- 310 W 01 0 V

9 2

8 3

4 7 7

5 5 Address 6 x1 PE PE 01

9 2

8 3

4 7 7 Address 5 5

6 x10

Configuration interface Power jumper contacts

This buscoupler connects the WAGO-I/O-SYSTEM as a slave to the CC-Link The local process image is divided into two data zones containing the data fieldbus. received and the data to be sent. The process data can be sent via the CC-Link fieldbus to the PLC, PC or NC for further processing, and received from the field The buscoupler automatically configures, creating a local process image which via CC-Link. may include analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes, digital data is sent bit by bit. The data of the analog modules is stored in the process image which is created automatically according to the order in which the modules are connected to the CC-Link stores the process image in the corresponding Master control (PLC, PC buscoupler. The bits of the digital modules are sent byte by byte and added to or NC). the analog data. If the amount of digital information exceeds 8 bits, the buscoupler automatically starts with a new byte.

Pack. Item No. Description Unit System Data CC-Link 750-310 1 No. of couplers connected to Master 64 Transmission medium Shielded Cu cable 2 / 3 x 0.5 mm² Max. length of bus line 100 m ... 1200 m (depends on baud rate/cable) Baud rate 156 Kbaud ... 10 Mbaud Buscoupler connection 1 x D-Sub 9; socket

Pack. Item No. Accessories Unit Miniature WSB Quick marking system plain 248-501 5 with marking see Section 11

Bus connector with D-Sub male connector; 750-965 1 9 poles Approvals

Conformity marking 1 Korea Certification r UL 508 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4 4 TÜV 07 ATEX 554086 X I M2 Ex d I Mb, II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C IECEx TUN 09.0001 X Ex d I Mb, Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc Permissible ambient temperature 0 °C ... +60 °C 4 181

I/O

modules S

FACE 24 V R 1 5 24 V 5 V ELECT RONIC S INTE FIELDBU 24 V /0 V 10 nF 5 V 0 V 2 6 24 V 24 V

FIELDBU S INTE RFACE 3 7

S 0 V 0 V 10 nF ONIC R

4 8 ELECT

750-310

Technical Data General Specifications

Number of I/O modules 64 Operating temperature 0 °C ... +55 °C Station addresses up to 4 Wire connection CAGE CLAMP ® Max. input process image 14-byte digital, Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 2-byte system, Strip lengths 8 ... 9 mm / 0.33 in 32-byte analog Dimensions (mm) W x H x L 51 x 65 x 100 Max. output process image 14-byte digital, Height from upper-edge of DIN 35 rail 2-byte system, Weight 210 g 32-byte analog Storage temperature -25 °C ... +85 °C Power supply 24 VDC (-25 % ... +30 %) Relative air humidity (no condensation) 95 % Max. input current (24 V) 500 mA Vibration resistance acc. to IEC 60068-2-6 Power supply efficiency 87 % Shock resistance acc. to IEC 60068-2-27 Internal current consumption (5 V) 300 mA Degree of protection IP20 Total current for I/O modules (5 V) 1700 mA EMC immunity of interference acc. to EN 61000-6-2 4.1 Isolation 500 V system/supply EMC emission of interference acc. to EN 61000-6-4 Voltage via power jumper contacts 24 VDC (-25 % ... +30 %) Current via power jumper contacts (max.) 10 A DC