HUMBOLDT-CATALOG-2017 COVER.Indd

Total Page:16

File Type:pdf, Size:1020Kb

HUMBOLDT-CATALOG-2017 COVER.Indd Air Meters 140-143 Beam Testing 151 Compression Testing 162-171 Consistency 147 Corrosion 178-180 Crack Monitors 190-191 Cube Molds 152 Cylinder Capping 160-161 Cylinder Molds 153 Cylinder Testing 154-155 Cylinder Prep 158-159 Freeze-Thaw 186-187 Ground Penetrating Radar 176 Humidifiers 156 Humidity 157 Initial Set 146 Linear Traverse 192 Maturity 148 Mixers 150 Moisture (Slabs) 188-189 Pull-Off 175 Pulse Echo 183 Rebar Locators 176-177 Rebound Test Hammers 172-173 Resistivity 184-185 Self Consolidating Concrete 149 Slump 144-145 Strain 192 Strength 174 Ultrasonic 181-183 Unit Weight 143 CONCRETE 140 Air Meters H-2784.500 H-2783 H-2784 Humboldt Super Air Meter bubbles meets the recommendations of the ACI piece, self-locking clamps that quickly seal the lid ASTM C231, AASHTO T152 201 Concrete Durability Committee. to the base with proper tension aided by an o-ring The H-2784 Super Air Meter (SAM) is a testing This new air meter has been investigated using to assure a watertight seal. A large, easy-to-read, device that measures both the air void spacing and more than 300 lab and field mixtures at Oklahoma 4-inch diameter, direct percentage gauge with air volume of plastic (fresh) concrete in about 10 State University and the FHWA Turner Fairbanks calibration adjustments is accurate to the nearest minutes. Air void spacing has been shown to be Laboratories. As part of an ongoing Pooled Fund 0.1%. The bucket features cast handles, which a better indicator of concrete freeze-thaw dura- Study, the SAM is being used by 10 different DOTs improve usability, especially when using bucket as bility than total air content; however, until now, it on field concrete. The results of this testing are a 0.25 cu. ft. unit weight measure. The lid of the has been challenging to measure in fresh concrete. also being compared to performance in an ASTM pressure meter features a smooth sloped top so By being able to measure the actual air-void spac- C666 rapid freeze-thaw test*. An AASHTO Provi- water and concrete wipe right off. By eliminating ing in fresh concrete, the meter helps users better sional Standard for this test has been approved. the cavities in the lid that trap and hold concrete, understand the freeze-thaw durability of their con- The meter is currently being used in 22 different maintenance and repair problems are greatly crete before it is placed. U.S. States and one Canadian Province. The SAM reduced. The meter also features a machined base, which ensures the meter sets level when conduct- The meter can function in two ways. First, it pro- has been specified in Oklahoma and Michigan on ing tests. The kit includes a durable plastic carry- vides all the same information as a Type B meter, transportation projects. ing case; a tamping rod; strike-off bar; rubber bulb under the same analytical conditions as a conven- The H-2784 includes one Super Air Meter testing syringe; plastic calibration vessel; inside calibra- tional pressure meter. After completing the con- device, and all accessories required to calibrate the tion tube, outside calibration tube and operating ventional testing the meter is then able to move meter and perform the type B or SAM tests. This instructions. into a second mode of operation that places the includes a calibrator; a mallet; safety glasses; strike- concrete under a series of higher pressures. By off board; a tamping rod; filling bulb and a durable, Humboldt Concrete Air Meter H-2783 Ship wt. 3lbs. (15.9kg) understanding how the concrete responds to the protective case. series of high pressures, the meter can assess prop- Humboldt Super Air Meter H-2784 erties of the air-void system beyond the air content. Ship wt. 4lbs. (15.9kg) The H-2784 Super Air Meter is a modified version CAPE System for Super Air Meter of a typical pressure meter (ASTM 231). The pri- ASTM C231, AASHTO T152 mary modification is that two sequential pressur- The CAPE Tank Accessory simplifies pressurization izations are applied to the concrete. The deforma- of the H-2784 Super Air Meter during testing, elim- tion of the concrete is first investigated at 14.5, 30, inating the need to manually pump to the required H-2789 H-2793 H-2788 and 45 psi, the pressure is then released, and the pressures. The tank is fitted with three inflation same pressure steps are used again to measure the chucks including regulators that are easily attached Air Meter Calibrators (5%) deformation. The differences between the first and to the pressurization valve of the Super Air Meter. Calibrators check the accuracy of any pressure-type second pressure steps are used to calculate the Super Air Meter Cape System H-2784.500 concrete air meter. Set the specially-designed can- SAM number, which is correlated with the average Ship wt. 4lbs. (15.9kg) ister upright at the bottom of the water-filled base, spacing between air voids in the concrete mixture. Humboldt Concrete Air Meter and the meter should read 5% air by volume. Two If the spacing between the voids is too high, then ASTM C231, AASHTO T152 calibrators are used for a 10% air reading. this could mean the concrete is susceptible to The H-2783 air meter features the Humboldt, all- Air Meter Calibrator, Brass H-2789 freeze-thaw deterioration. A SAM number of 0.20 brass super pump, the most reliable and highest Air Meter Calibrator, Aluminum H-2793 has been shown to correctly determine over 90% quality pump available. The meter's easy-to-use, Air Meter Calibrator, Plastic H-2788 of the time whether the spacing between the stainless steel clamping system employs four, one- Ship wt 3 lb (1 3kg) www.humboldtmfg.com • 1.800.544.7220 • 708.468.6300 CONCRETE Air Meters 141 H-2755 H-2756 H-2786C H-2786 H-2786P Concrete Air Meter Press-Ur-Meter Concrete Air Meter Chace Concrete Air Indicator Kit ASTM C231, AASHTO T152 ASTM C231, AASHTO T152 AASHTO T199 The H-2786C air meter features a simplified, This is the original Press-Ur-Meter for fi eld and (Isopropyl-Alcohol Method) Complete kit for low-maintenance design, which uses no moving laboratory tests. This air meter is designed to pro- measuring air content of fresh concrete includes parts inside the chamber. Pressure is released into vide air content and the determination of specifi c H-2755 air indicator, instructions, cleaning brush the base by an external, brass, quick-release T-valve. gravity and free moisture of aggregate. Designed and plastic squeeze-type bottle for alcohol in plas- The meter uses brass cover clamps, which can be to save time, reduce water use, ensure accuracy tic storage box. Kit does not replace conventional adjusted for clamping pressure. A large, easy-to- and maintain sample integrity (sample may also be air meters. read, 4" diameter, direct percentage gauge with used for slump and compression tests). The meter Chace Concrete Air Indicator Kit H-2756 calibration adjustments is accurate to the nearest uses brass cover clamps, which can be adjusted Ship wt 1 4lbs (1 8kg) 0.1%. The base is machined inside and out for easy for clamping pressure. A large, easy-to-read, 4" Chace Concrete Air Indicator cleaning and the chamber and cover are one solid diameter, direct percentage gauge with calibra- AASHTO T199 component, eliminating bottom gasket leaks. The tion adjustments is accurate to nearest 0.1%.The For quick fi eld checks for air content of fresh concrete H-2786C air meter also features the Humboldt, all- H-2786 meter also features the Humboldt, all- in about three minutes, pocket-sized unit air meter is brass super pump, the most reliable and highest brass super pump, the most reliable and highest furnished with instructions and correlation chart. Unit quality pump available. The meter's base/bucket quality pump available. The meter's base/bucket does not replace conventional air meters. Overall can be used as a 0.25 cu. ft. unit weight measure. can be used as a 0.25 cu. ft. unit weight measure. dimensions: 6.25 x 1.125" dia. (159 x 29mm). The kit includes a durable plastic carrying case; The kit includes a wood or molded-plastic carry- Chace Concrete Air Indicator H-2755 tamping rod; strike-off bar; wash bottle; plastic cal- ing case; tamping rod; strike-off bar; rubber bulb Ship wt. 0.25lbs. (.45kg) ibration vessel; inside calibration tube, outside cali- syringe; aluminum calibration vessel; inside cali- Chace Air Indicator Glass Filter Tube Only bration tube and operating instructions. bration tube, outside calibration tube and operat- AASHTO T199 Concrete Air Meter H-2786C ing instructions. Ship wt. 34.9lbs. (15.9kg) Chace Glass Filter Tube only H-2755 2 Press-Ur-Meter Concrete Air Meter H-2786P Ship wt. 0.2lbs. (.45kg) Air Meter Replacement Accessories Press-Ur-Meter with vertical wood case H-2786 Ship wt 30lbs (15 9kg) Item Part No. Calibration Vessel, plastic H-2783.30 Calibration Vessel, metal H-2785.31 Calibration Tube (outside) H-2785.32 H-2785.DB Calibration Tube (inside) H-2785.33 Super Pump for Air Meters Wash Bottle H-3399 Step up to the quality and reliability of the Hum- Strike-off Bar H-2785.34 boldt super pump. The super pump’s all brass con- Tamping Rod 5/8" x 16" H-2785.35 struction resists acids in cement. All parts, includ- ing valve, are replaceable. For use with all type B Syringe, Rubber Bulb H-2785.36 air meters.
Recommended publications
  • Ts-63-34.00-001
    IDM UID YHM3FJ VERSION CREATED ON / VERSION / STATUS 09 Jun 2020 / 2.1 / Approved EXTERNAL REFERENCE / VERSION Technical Specifications (In-Cash Procurement) TS-63-34.00-001 - IOTS - 000001 : Technical Specifications B50s Grouting and related works This document provides requirements for grouting works and accompanied surface preparation and oil-resistant painting works to be performed on IO platform in B50s (B51/B52/A53) in order to complete the interface between PBS63 and each of PBS34.10 and PBS34.40. PDF generated on 15 Jun 2020 DISCLAIMER : UNCONTROLLED WHEN PRINTED – PLEASE CHECK THE STATUS OF THE DOCUMENT IN IDM ITER_D_YHM3FJ v2.1 Table of Contents 1 PURPOSE ............................................................................................................................ 2 2 SCOPE ................................................................................................................................. 2 3 DEFINITIONS .................................................................................................................... 2 4 DURATION ......................................................................................................................... 3 5 WORK DESCRIPTION ..................................................................................................... 3 5.1 Scope of Works ............................................................................................................. 3 5.2 Grouting volume and preparation work ...................................................................
    [Show full text]
  • ~EERING DMSION~ , Depar1l.4ENT of PUBLIC WORKS
    Q INFORMATION FOR BIDDERS PROPOSAL - SPECIFICATIONS FOR REPLACEMENT OF lHE ONEIDA DRIVE BRIDGE OVER SMITH COVE (BRIDGE NO. 056-009) PROJECT NO. 14-20 MARCH 2019 0 0 ~~EERING DMSION~ , DEPAR1l.4ENT OF PUBLIC WORKS ~ .4" INVITATION TO BID Sealed bids, one (I) original and two (2) copies, will be received in the Office of the Purchasing Department and shall be opened and read aloud in the Gisborne Conference Room, Town Hall, 101 Field Point Road, Greenwich, Connecticut at 2 o'clock pm (prevailing time) on Wednesday, Apri110, 2019 for the following work: Replacement of the Oneida Drive Bridge over Smith Cove (Bridge No. 056-009) Town Project No. 14-20 A Bid Bond for 10% of the total bid must accompany each bid. Bidders may be required to submit data covering financial resources, equipment and ability to perform the work rapidly and in a satisfactory manner. The right is expressly reserved to reject any or all bids, to waive any informalities in the bids, or to accept such bids as appear to be in the best interest of the Town. Specifications may be obtained on the Town ·s website, www.greemvicbcl.om. It is the responsibility of the prospective bidder to check the website for any addenda issued up to 48 hours prior to the bid opening. Drawings and specifications will be posted to the Town's website and may be downloaded at no cost. Drawings taken from the Town's website and printed on the bidder's equipment may not be to scale. Full size hard c~ies of the drawings may be purchased from Greenwich Blueprint, LLC, 255 Greenwich Avenue, 2" floor, Greenwich, CT 06830, ph.
    [Show full text]
  • Performance-Based Specifications and Control of Concrete Durability This Publication Has Been Published by Springer in September 2015, ISBN 978-94-017-7308-9
    STAR 230-DUC Performance-Based Specifications and Control of Concrete Durability This publication has been published by Springer in September 2015, ISBN 978-94-017-7308-9. This STAR report is available at the following address: http://www.springer.com/978-94-017-7308-9 Please note that the following PDF file, offered by RILEM, is only a final draft approved by the Technical Committee members and the editors. No correction has been done to this final draft which is thus crossed out with the mention « Unedited version » as requested by Springer. RILEM TC 230-PSC Performance-Based Specifications and Control of Concrete Durability State-of-the-Art Report Please note that the Table of Contents of the unedited version doesn’t include Chapter 6 which was in LateX format and added later.version Page numbering is not correct. Unedited version Unedited Contents Contents i 1. Introduction 5 H. Beushausen 5 1.1 Background to the work of TC 230-PSC 5 1.2 Terminology 7 References 10 2. Durability of Reinforced Concrete Structures and Penetrability 11 L.-O. Nilsson, S. Kamali-Bernard, M. Santhanam 11 2.1 Introduction 11 2.2 Mechanisms Causing Reinforcement Corrosion 11 2.2.1 Carbonation 11 2.2.2 Chloride Ingress 12 2.3 Concrete Properties Relating to the Ingress of Aggressive Agents 12 2.3.1 Resistance against Diffusion of CO2 12 2.3.2 Moisture Transport Properties 14 2.3.3 Resistance against Chloride Diffusion and Convection 15 2.4 Service Life and Deterioration Models (Principles) 16 2.4.1 Carbonation Models, In Principle 17 2.4.2 Chloride Ingress Models, In Principle 18 2.4.3 Discussion on the Influence of Cracks version 19 References 19 3.
    [Show full text]
  • Taking the Mystery out of Mix Design in Part 1 of 2, Ken Hover Covers the Three Factors That Defi Ne a Concrete Mix
    INSIDE: CONCRETE SURFACES November/December 2019 An Offi cial Magazine of World of Concrete Taking the Mystery Out of Mix Design In Part 1 of 2, Ken Hover covers the three factors that defi ne a concrete mix. Pg 19 Pumping Dry Materials Pg 29 Installing a Thermal Break Pg 35 ONE-PASS POWERHOUSES When it comes to slab-on-grade, we’re talkin’ serious work ethic. Our award-winning boomed screeds are designed to help you do more with less. Make major efficiency gains ® on the projects where quality and reliability matter most. Come see these and our full line of Laser Screed® Machines at World of Concrete 2020 - BOOTH C5303. ® WWW.SOMERO.COM Get it Done. Get a Somero. or call 239.210.6519 CONTENTS November/December 2019 / Volume 64 / Number 7 19 Photo: Votorantim Cimentos/Prairie Materials FEATURES DEPARTMENTS 19 Taking the Mystery Out of Mix Design 5 Insider Information CS-41 Tie a Yellow Ribbon Learn how the various ingredients in a Come to WOC Again Sometimes the concrete mix come together in Part 1 of this only way to fi x two-part article. 10 Projects That Rock a bad polishing job A Formwork Challenge is to start over. 29 Material Placement Made Easy Fill and subgrade materials can be air-pumped 12 Business CS-45 Getting Consistent into inaccessible locations. Your Company’s Culture is Critical Results on Polished Concrete Overlays 35 Insulating Concrete Balconies 16 Uncommon Sense Follow these three steps for Structural thermal breaks are increasingly Leading Our Laborers a successful installation.
    [Show full text]
  • Workshop on Nanotechnology for Cement and Concrete September 5, 2007
    Workshop on Nanotechnology for Cement and Concrete September 5, 2007 Report of the Workshop on Nanotechnology for Cement and Concrete September 5, 2007 Peter Taylor Krishna Rajan Bjorn Birgisson Tom Cackler Sponsored by The National Concrete Pavement Technology Center and the National Science Foundation, in Cooperation with the Nanoscale Science, Engineering, and Technology (NSET) Subcommittee of the U.S. National Science and Technology Council, through the National Nanotechnology Coordination Office Acknowledgments The workshop was sponsored by The National Concrete Pavement Technology Center and the National Science Foundation, in Cooperation with the Nanoscale Science, Engineering, and Technology (NSET) Subcommittee of the U.S. National Science and Technology Council, through the National Nanotechnology Coordination Office. Travel support for most state department of transportation and university attendees and support for development of this report were made possible by NSF Grant CMMI 0749499. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the National Science Foundation. Thanks go to the presenters for permission to reproduce their presentations. I Workshop on Nanotechnology for Cement and Concrete Cement for on Nanotechnology Workshop I ii Preface This document summarizes the discussions and findings of a workshop held in Arlington, VA, on September 5, 2007. The objective of the meeting was to provide national direction on
    [Show full text]
  • Notice to Bidders, Specifications and Proposal
    145 Letting March 8, 2019 Notice to Bidders, Specifications and Proposal Contract No. 61F45 KANE County Section 16-00115-02-BR Route FAP 526 (Silver Glen Road) Project HILS-183 () District 1 Construction Funds Prepared by F Checked by (Printed by authority of the State of Illinois) NOTICE TO BIDDERS 1. TIME AND PLACE OF OPENING BIDS. Electronic bids are to be submitted to the electronic bidding system (iCX-Integrated Contractors Exchange). All bids must be submitted to the iCX system prior to 10:00 a.m. March 8, 2019 at which time the bids will be publicly opened from the iCX SecureVault. 2. DESCRIPTION OF WORK . The proposed improvement is identified and advertised for bids in the Invitation for Bids as: Contract No. 61F45 KANE County Section 16-00115-02-BR Project HILS-183 () Route FAP 526 (Silver Glen Road) District 1 Construction Funds Replace the bridge carrying Silver Glen Road over Otter Creek. 3. INSTRUCTIONS TO BIDDERS . (a) This Notice, the invitation for bids, proposal and letter of award shall, together with all other documents in accordance with Article 101.09 of the Standard Specifications for Road and Bridge Construction, become part of the contract. Bidders are cautioned to read and examine carefully all documents, to make all required inspections, and to inquire or seek explanation of the same prior to submission of a bid. (b) State law, and, if the work is to be paid wholly or in part with Federal-aid funds, Federal law requires the bidder to make various certifications as a part of the proposal and contract.
    [Show full text]
  • Effects of Concrete Moisture on Polymer Overlay Bond Over New Concrete
    Report No. K-TRAN: KSU-13-3 ▪ FINAL REPORT▪ June 2015 Effects of Concrete Moisture on Polymer Overlay Bond Over New Concrete Andrew Joseph Shearrer Kyle A. Riding, Ph.D., P.E. Robert J. Peterman, Ph.D., P.E. Kansas State University Transportation Center 1 Report No. 2 Government Accession No. 3 Recipient Catalog No. K-TRAN: KSU-13-3 4 Title and Subtitle 5 Report Date Effects of Concrete Moisture on Polymer Overlay Bond Over New Concrete June 2015 6 Performing Organization Code 7 Author(s) 7 Performing Organization Report Andrew Joseph Shearrer, Kyle A. Riding, Ph.D., P.E., Robert J. Peterman, Ph.D., No. P.E. 9 Performing Organization Name and Address 10 Work Unit No. (TRAIS) Kansas State University Transportation Center Department of Civil Engineering 11 Contract or Grant No. 2118 Fiedler Hall C1943 Manhattan, Kansas 66506 12 Sponsoring Agency Name and Address 13 Type of Report and Period Kansas Department of Transportation Covered Bureau of Research Final Report 2300 SW Van Buren August 2012–August 2014 Topeka, Kansas 66611-1195 14 Sponsoring Agency Code RE-0594-01 15 Supplementary Notes For more information write to address in block 9. Appendices are available in a separate PDF. http://ksdot1.ksdot.org/burmatrres/kdotlib2.asp or [email protected]. Epoxy polymer overlays have been used for decades on existing bridge decks to protect the deck and extend its service life. The polymer overlay’s ability to seal a bridge deck is now being specified for new construction. Questions exist about the amount of drying time needed to achieve an acceptable concrete moisture content to ensure an adequate bond to the polymer overlay.
    [Show full text]
  • Tio2 Photocatalysis in Portland Cement Systems: Fundamentals of Self Cleaning Effect and Air Pollution Mitigation
    TiO2 photocatalysis in Portland cement systems: fundamentals of self cleaning effect and air pollution mitigation By Andrea Folli, M. Sc., University of Milan, ITALY A thesis presented for the degree of Doctor of Philosophy at the University of Aberdeen Department of Chemistry University of Aberdeen 2010 Declaration I hereby declare that this thesis: 1. has been composed by Andrea Folli, i.e. the candidate for the degree of Doctor of Philosophy; 2. has not been accepted in any previous application for a degree; 3. has been entirely done by the candidate; 4. all quotations have been distinguished by quotation marks and the sources of information specifically acknowledged. Aberdeen, 13.10.2010 Andrea Folli Acknowledgements …da chimico un giorno avevo il potere di sposar gli elementi e farli reagire… ”Un chimico”, Fabrizio De André When I look back at the years of my PhD in Aberdeen I see without doubt one of the best periods of my life. Years of discovery: personal discovery above all. I discovered new characteristics and features about myself that I did not know existed. I discovered the thrill of jumping into an unknown culture without properly speaking the language. Along with the day by day quest of learning; learning how to integrate, learning how to handle situations and events far different from what I had learnt from my own culture, yet finding myself at home from the very first moment. I discovered how important it was to question myself and what I do, because my own reality holds its own perspective. I discovered that if I embrace any point of view, any different opinions and any critics I can abandon fear and open myself up to experience life at its greatest purpose.
    [Show full text]
  • Application with Self-Healing Concrete in Belgium: Analysis of the Laboratory Control Tests
    materials Article First Large Scale Application with Self-Healing Concrete in Belgium: Analysis of the Laboratory Control Tests Tim Van Mullem 1 , Elke Gruyaert 2, Robby Caspeele 1 and Nele De Belie 1,* 1 Magnel-Vandepitte Laboratory, Department of Structural Engineering and Building Materials, Faculty of Engineering and Architecture, Ghent University, Tech Lane Ghent Science Park, Campus A, Technologiepark Zwijnaarde 60, B-9052 Gent, Belgium; [email protected] (T.V.M.); [email protected] (R.C.) 2 Department of Civil Engineering, KU Leuven, Ghent Technology Campus, Gebroeders De Smetstraat 1, 9000 Ghent, Belgium; [email protected] * Correspondence: [email protected]; Tel.: +32-92645522 Received: 21 January 2020; Accepted: 20 February 2020; Published: 23 February 2020 Abstract: Due to the negative impact of construction processes on the environment and a decrease in investments, there is a need for concrete structures to operate longer while maintaining their high performance. Self-healing concrete has the ability to heal itself when it is cracked, thereby protecting the interior matrix as well as the reinforcement steel, resulting in an increased service life. Most research has focused on mortar specimens at lab-scale. Yet, to demonstrate the feasibility of applying self-healing concrete in practice, demonstrators of large-scale applications are necessary. A roof slab of an inspection pit was cast with bacterial self-healing concrete and is now in normal operation. As a bacterial additive to the concrete, a mixture called MUC+, made out of a Mixed Ureolytic Culture together with anaerobic granular bacteria, was added to the concrete during mixing.
    [Show full text]
  • Moisture Measurement in Concrete & Wood
    2010 NICFI Convention Moisture Measurement in Concrete and Wood Correct Usage and Application Moisture Sources precipitation dew point T-2 dew point T-1 ambient sub-slab RH vapor osmosis hydrostatic sub-slab water Picture Courtesy of CTLGroup Concrete Equilibrates with the Occupied Space Air Drier concrete moisture Wet Vapor retarder Sub-base When floor covering or coating is first applied, the moisture at the surface may still be OK, but… Floor covering Drier 75% 85% Wet 98% Shortly after the initial installation, the moisture in the slab will quickly equilibrate within the slab; bad news at the surface, and then… Slab Surface now wet 85% Floor covering 85% 85% Serious and Costly Failures and Damage Photos Courtesy CTLGroup, George Donnelly, CFI Drying Rate of Concrete • Rule-of-Thumb is minimum of 30 days of drying time per inch thickness of concrete to reach approximately 85% RH • Above assumes good drying conditions (HVAC on, no additional water, .40-.50 water/cement ratio) • Many factors can impact the minimum time • Even very old slabs can have high moisture Picture Courtesy of CTLGroup Why Measure Moisture? • Meet flooring manufacturer’s warranty requirements • Minimize potential IAQ problems • Minimize moisture-induced failures • Contractual obligation Basically, minimize liability and financial loss Approaches to Measuring Moisture QUALITATIVE-ONLY QUANTITATIVE • Plastic Sheet Test • Moisture Vapor Emission Rate • Mat Bond Test • Relative Humidity • Electrical Resistance moisture meters • Gravimetric (core sampling, lab analysis;
    [Show full text]
  • X” Are Applicable to This Contract and Are Included by Reference
    RECURRING SPECIAL PROVISIONS The following RECURRING SPECIAL PROVISIONS indicated by an “X” are applicable to this contract and are included by reference: CHECK SHEET # PAGE NO. 1 X Additional State Requirements for Federal-Aid Construction Contracts .............. 75 2 X Subletting of Contracts (Federal-Aid Contracts) .................................................. 78 3 X EEO ...................................................................................................................... 79 4 Specific EEO Responsibilities Non Federal-Aid Contracts .................................. 89 5 Required Provisions - State Contracts ................................................................. 94 6 Asbestos Bearing Pad Removal .......................................................................... 100 7 Asbestos Waterproofing Membrane and Asbestos HMA Surface Removal ........ 101 8 Temporary Stream Crossings and In-Stream Work Pads .................................... 102 9 Construction Layout Stakes Except for Bridges ................................................... 103 10 X Construction Layout Stakes ................................................................................. 106 11 Use of Geotextile Fabric for Railroad Crossing .................................................... 109 12 Subsealing of Concrete Pavements ..................................................................... 111 13 Hot-Mix Asphalt Surface Correction ..................................................................... 115 14 X Pavement and
    [Show full text]
  • METHOD STATEMENT Sikalevel® Product Preparation 9/23/2021 | Version 5.0 | Sika Corporation Method Statement Sikalevel Products 9/23/2021, Version 5.0
    METHOD STATEMENT SikaLevel® Product Preparation 9/23/2021 | Version 5.0 | Sika Corporation Method Statement SikaLevel Products 9/23/2021, Version 5.0 TABLE OF CONTENTS 1 System Description 3 1.1 Scope 3 1.2 General Project Requirements 3 2 Products 4 2.1 System 4 2.2 Products 4 2.2.1 Surface Repair 4 2.2.2 Moisture Mitigation and Consolidation 4 2.2.3 Primers 5 2.2.4 Self-Leveling 5 2.3 Product Selection Criteria 6 2.3.1 Selection Chart 6 2.3.2 Build-ups 8 3 Site Conditions 8 3.1 Water Supply 8 3.2 Power Supply 8 3.3 Material Storage / Access / Transportation 9 3.4 Safety Measures on Site 9 3.4.1 Labor Protection 9 3.4.2 cleaning, Recycling and Disposal 9 3.5 Preliminary Work 10 3.5.1 Substrate Evaluation 10 3.5.2 Base Substrate Requirements 10 3.5.3 Preparation 10 3.5.4 Checking of the Flatness 10 3.5.5 Surface Treatment 11 3.5.6 Cracks and Joints 12 3.5.7 Amount of Material 14 3.6 Equipment for Application 14 3.6.1 Tools 14 3.6.2 Pump 16 3.7 Environmental Requirements 16 3.7.1 Temperature 16 3.7.2 Humidity 16 4 Surface Repair 17 5 Epoxies 18 5.1 Subfloor Preparation 19 19 5.2 Application 19 6 Primers 21 6.1 Sika® Level-01 Primer plus 21 6.2 Sika® Level-02 EZ Primer 22 6.3 Application 22 7 Self-Leveling Underlayements 23 7.1 Division and Different Stages of Working Areas 23 7.2 Mixing 24 7.3 Pump Mixing 24 7.4 Extension with aggregates 26 8 Clean up 27 8.1 Epoxy Products 27 8.2 Acrylic Products 27 8.3 Cementitious Products 27 Legal Note 27 For Review , 2/27 Method Statement SikaLevel Products 9/23/2021, Version 5.0 1 SYSTEM DESCRIPTION 1.1 SCOPE This document is a guide for contractors, applicators and instructors for handling the materials and application of Sika® Level products and systems.
    [Show full text]