PRICE CATALOG Your Source for Construction Materials Testing Equipment About Us

Total Page:16

File Type:pdf, Size:1020Kb

PRICE CATALOG Your Source for Construction Materials Testing Equipment About Us 2021 PRICE CATALOG Your Source for Construction Materials Testing Equipment About Us Myers has been providing quality products and services throughout the United States since 1994. One phone call gives you access to over 50 of the top manufacturers in the U.S. We shop for you to find the best prices available. Count on us for all of your construction materials testing equipment needs. Contact Us Bob Myers Fran Myers Founder, President President, Accounts Receivables 207-289-1555 207-289-1561 [email protected] [email protected] Andrew Myers Meaghan Myers Jacobson VP, Sales VP, Marketing & AP 207-289-1562 207-289-1556 [email protected] [email protected] Corey Jacobson Jeff Clouatre Sales Manager Sales Associate 207-289-1557 207-819-1025 [email protected] [email protected] Get Directions Trever Clouatre Logistics Manager 207-289-1958 [email protected] [email protected] myerstest.com 888.293.2121 TABLE OF CONTENTS Concrete.........................................................4 Cement..........................................................37 Aggregate....................................................48 Soil-Field.......................................................70 Soil-Lab.........................................................80 Asphalt..........................................................93 General Lab...............................................105 Pricing in this catalog is subject to change without notice. Please call or email for current pricing 888.293.2121 or [email protected] 4 Air Content Air Indicator. .6 Air Meter Replacement Parts. 7-8 Air Meter Refurbishing. 8-9 Pressure Air Meters. 6 Roller Meters. .6 Roller Meter Replacement Parts. 10 Beam Testing. .20 Compression Testing Compressometers. .19 Digital Indicators. 18 Machines. 15-16 Machine Accessories. .17-18 Consistency. 36 Cylinder Molds Plastic Molds. 11-12 Steel Molds. .12 Cylinder Testing & Prep Cylinder Accessories. 14 Cylinder Capping. .13-14 End Grinder. 14 Pads & Rings. 13 Field Curing. .23 Lab Curing. 21-22 Measuring Devices. .24 Moisture Moisture Meters. 33 Relative Humidity. .32 Vapor Emission Test. 33 Non-Destructive Corrosion Analysis. .29 Crack Monitors. 27 Freeze Thaw. 31 Masonry Strain. 31 Permeability Testing. .28 Pull Off Testing. 30 Rebar Locators. 27 Rebound Hammers. 26 Surface Resistivity. .28-29 Ultrasonic Testing. 30 Windsor Systems. 26 SCC (Self Consolidating Concrete). 20 Set Time. 36 Slump. .5 Testing Accessories. 34 Thermometers. .35 Unit Weight. 25 5 CONCRETE Slump Testing Slump Cone - Metal Slump Cone - Plastic ASTM C143, AASHTO T119 ASTM C143, AASHTO T119 The metal slump cone is spun from heavy gauge steel and is The plastic slump cone is inexpensive and seamless to provide a stronger, more durable product that lightweight. It will not rust or dent and can be is easy to clean. All parts of the cone are plated for rust cleaned in an acid bath if necessary. The cone resistance. The cone has an 8” open base, 4” top, and an has an 8” open base, 4” top, and an overall height overall height of 12”. of 12”. SC Metal Slump Cone $42.00 PSC Plastic Slump Cone $24.00 Slump Cone Base - Aluminum Slump Cone Base - Poly ASTM C143, AASHTO T119 ASTM C143, C143M; AASHTO T119 The 18” x 18” slump cone base is made of The slump cone base plate is made from cast aluminum. high-density polyethylene. The base has Attached base clamps rotate over the foot lugs to secure adjustable clamps that secure the slump the slump cone during filling. Once the slump cone is cone and spring-loaded rod clamps to lifted, the handle rotates vertically over the sample to allow easy transport. It is easily cleaned facilitate measurement of the resulting concrete slump. and will not corrode. $109.95 HM-212 Aluminum Slump Cone Base ACM-31 Poly Slump Base $78.00 Economy Slump Base Slump Cone Test Set ASTM C143, AASHTO T119 ASTM C143, AASHTO T119 The portable slump test set includes all tools The economy slump base is fabricated from a 1/4" necessary to conduct a slump test on a sample aluminum plate for strength and rigidity. The base can of freshly mixed concrete. The unique base be used to consolidate an entire slump testing set into design allows all components to be combined one, easy to carry unit. into a one-piece unit. The attached handle can be rotated above the specimen and used as a SCEBP Economy Slump Base 18” x 18” $79.00 guide to measure the slump. The set includes the base with cone, attached hold down SCEBP-XL Economy Slump Base 24” x 24” $108.75 clamps, slump cone, tamping rod, and scoop. Poly Slump Cone Set HM-220 Slump Cone Set $147.95 ASTM C143, AASHTO T119 The portable poly slump cone test set includes Deluxe Slump Cone Set all tools necessary to conduct a slump test on ASTM C143, AASHTO T119 a sample of freshly mixed concrete. The poly The deluxe slump cone set provides all the equipment slump base is easy to clean and lightweight. It needed to perform at slump test. The set includes a features both adjustable hold down clamps and slump cone, base, funnel, scoop, cleaning brush, and rod clamps, which doubles as a carrying handle. tamping rod, and tape measure. The metal slump The set includes the poly base with attached cone is spun from heavy gauge steel, is rust resistant, hold down clamps, metal slump cone, tamping and seamless to provide a stronger, more durable rod, and scoop. product that is easy to clean. ACM-3K Poly Slump Cone Set $125.00 HM-220D Deluxe Slump Cone Set $179.95 Economy Slump Cone Set Slump Cone Set with Pan ASTM C143, AASHTO T119 ASTM C143, AASHTO T119 The economy slump cone set includes all the equipment The slump cone test set includes all tools necessary to conduct a slump test of freshly mixed concrete. necessary to conduct a slump test on a sample The set includes a fabricated aluminum slump cone base, of freshly mixed concrete. The set includes the steel or plastic seamless slump cone, graduated tamping rod, galvanized metal pan with handles, metal slump and 38oz. scoop. cone, tamping rod, scoop, trowel, and bristle brush. SCEBP-KIT Slump Cone Set with Metal Cone $137.00 HM-41 Slump Cone Set with Pan $123.95 SCEBP-KIT-P Slump Cone Set with Plastic Cone $120.00 Tape Measure Slump Cone Funnel K-Slump Tester ASTM C143, C143M; AASHTO T119 ASTM C1362 • High strength rubber case • Easy to read markings The k-slump tester indicates correlation to slump tests • Extra thick blade for in-place forms and molds. The probe determines • Easy to use thumb lock The slump cone funnel is a convenient accessory for fast and easy filling of slump cones and also allows workability of concrete and degree of compactions after • Graduated in 1/16”, 1/8”, 1” and 1’ stud being placed. findings the use of larger scoops. HM-65 K Slump Tester $186.00 TM-16 Tape Measure 16’ x 3/4” $3.99 H-3638 Slump Cone Funnel $22.80 [email protected] myerstest.com 888.293.2121 Air Meters CONCRETE 6 Pressure Meters Type B Pressure Meter with ACM Style Carrying Case Type B Pressure Meter with Toolbox Style Carrying Case ASTM C231, AASHTO T152 ASTM C231, AASHTO T152, Calibration Certificate The pressure air meter measures entrained air in normal weight fresh mixed concrete. It The pressure air meter measures entrained has an easy to use and easy to read gauge with air in normal weight fresh mixed concrete. calibration adjustments. Its brass pump builds The handles on the bucket make the meter test pressure faster, using fewer strokes. The kit easier to carry. The kit comes complete with comes complete with the meter, plastic carrying the meter, plastic carrying case, bulb syringe, case, bulb syringe, tamping rod, strike off bar, tamping rod, strike off bar, and calibration rubber mallet, calibration vessel, inside/outside equipment. calibration tubes, and calibration certificate. CA-0500 Pressure Meter Kit $635.00 ACM-6 Pressure Meter Kit $599.95 CA-0501 Pressure Meter Only $545.00 ACM-6A Pressure Meter Only $499.95 Press-Ur-Meter (Watts Style Meter with Upright Plastic Case) Type B Pressure Meter with Flat Gauge Mount ASTM C231, AASHTO T152 ASTM C231, AASHTO T152 The original Press-Ur-Meter for field and The pressure air meter measures entrained laboratory tests is designed to determine air air in normal weight fresh mixed concrete. content, determination of specific gravity and For convenience, the tare weight in grams is free moisture test of aggregates. The Watts stamped on the bottom. When used with the Style meter has “j-hook” shaped latch tabs and supplied nomograph, the air meter provides comes complete with the meter, plastic-upright quick and easy particle density and percent carrying case, bulb syringe, tamping rod, strike of free moisture in aggregate determinations. off bar, calibration vessel, and inside/outside The meter is supplied with an aluminum calibration tubes. tamping bar. H-2786P Press-Ur-Meter Kit $750.00 HM-265 Pressure Meter Kit $781.25 Super Air Meter Air Indicator Super Air Meter Chace Air Indicator Kit ASTM C231; AASHTO TP118 AASHTO T199 • Digital Gauge • Measures the volume and spacing of air voids in fresh concrete • Measurements compare to hardened air void analysis (ASTM C457) and The air indicator kit is recommended for fast estimating of air content of fresh freeze-thaw testing (ASTM C666) concrete. The method is ideal for rapid field judgments or for determining that • Determines accurate air content of a more thorough air meter test is needed. The kit includes the air indicator, concrete before placement instructions, cleaning brush, plastic squeeze bottle and plastic storage box. SAM1 Super Air Meter Kit $3,175.00 H-2756 Chace Air Indicator Kit $40.00 SAM2 Super Air Meter Only $2,670.00 HMA-1A Chace Air Indicator Only $24.00 Replacement Parts A-102 Chace Air Glass Tube $20.50 A-103 Stopper for Glass Tube $14.50 Roller Meters Volumetair Plastic Roller Meter Aluminum Roller Meter ASTM C173; AASHTO T196 ASTM C173; AASHTO T196 The lightweight aluminum roller meter simply and The Volumetair is used for the rolling method of accurately measures the air content of any fresh measuring entrained air in any concrete.
Recommended publications
  • Ts-63-34.00-001
    IDM UID YHM3FJ VERSION CREATED ON / VERSION / STATUS 09 Jun 2020 / 2.1 / Approved EXTERNAL REFERENCE / VERSION Technical Specifications (In-Cash Procurement) TS-63-34.00-001 - IOTS - 000001 : Technical Specifications B50s Grouting and related works This document provides requirements for grouting works and accompanied surface preparation and oil-resistant painting works to be performed on IO platform in B50s (B51/B52/A53) in order to complete the interface between PBS63 and each of PBS34.10 and PBS34.40. PDF generated on 15 Jun 2020 DISCLAIMER : UNCONTROLLED WHEN PRINTED – PLEASE CHECK THE STATUS OF THE DOCUMENT IN IDM ITER_D_YHM3FJ v2.1 Table of Contents 1 PURPOSE ............................................................................................................................ 2 2 SCOPE ................................................................................................................................. 2 3 DEFINITIONS .................................................................................................................... 2 4 DURATION ......................................................................................................................... 3 5 WORK DESCRIPTION ..................................................................................................... 3 5.1 Scope of Works ............................................................................................................. 3 5.2 Grouting volume and preparation work ...................................................................
    [Show full text]
  • HUMBOLDT-CATALOG-2017 COVER.Indd
    Air Meters 140-143 Beam Testing 151 Compression Testing 162-171 Consistency 147 Corrosion 178-180 Crack Monitors 190-191 Cube Molds 152 Cylinder Capping 160-161 Cylinder Molds 153 Cylinder Testing 154-155 Cylinder Prep 158-159 Freeze-Thaw 186-187 Ground Penetrating Radar 176 Humidifiers 156 Humidity 157 Initial Set 146 Linear Traverse 192 Maturity 148 Mixers 150 Moisture (Slabs) 188-189 Pull-Off 175 Pulse Echo 183 Rebar Locators 176-177 Rebound Test Hammers 172-173 Resistivity 184-185 Self Consolidating Concrete 149 Slump 144-145 Strain 192 Strength 174 Ultrasonic 181-183 Unit Weight 143 CONCRETE 140 Air Meters H-2784.500 H-2783 H-2784 Humboldt Super Air Meter bubbles meets the recommendations of the ACI piece, self-locking clamps that quickly seal the lid ASTM C231, AASHTO T152 201 Concrete Durability Committee. to the base with proper tension aided by an o-ring The H-2784 Super Air Meter (SAM) is a testing This new air meter has been investigated using to assure a watertight seal. A large, easy-to-read, device that measures both the air void spacing and more than 300 lab and field mixtures at Oklahoma 4-inch diameter, direct percentage gauge with air volume of plastic (fresh) concrete in about 10 State University and the FHWA Turner Fairbanks calibration adjustments is accurate to the nearest minutes. Air void spacing has been shown to be Laboratories. As part of an ongoing Pooled Fund 0.1%. The bucket features cast handles, which a better indicator of concrete freeze-thaw dura- Study, the SAM is being used by 10 different DOTs improve usability, especially when using bucket as bility than total air content; however, until now, it on field concrete.
    [Show full text]
  • ~EERING DMSION~ , Depar1l.4ENT of PUBLIC WORKS
    Q INFORMATION FOR BIDDERS PROPOSAL - SPECIFICATIONS FOR REPLACEMENT OF lHE ONEIDA DRIVE BRIDGE OVER SMITH COVE (BRIDGE NO. 056-009) PROJECT NO. 14-20 MARCH 2019 0 0 ~~EERING DMSION~ , DEPAR1l.4ENT OF PUBLIC WORKS ~ .4" INVITATION TO BID Sealed bids, one (I) original and two (2) copies, will be received in the Office of the Purchasing Department and shall be opened and read aloud in the Gisborne Conference Room, Town Hall, 101 Field Point Road, Greenwich, Connecticut at 2 o'clock pm (prevailing time) on Wednesday, Apri110, 2019 for the following work: Replacement of the Oneida Drive Bridge over Smith Cove (Bridge No. 056-009) Town Project No. 14-20 A Bid Bond for 10% of the total bid must accompany each bid. Bidders may be required to submit data covering financial resources, equipment and ability to perform the work rapidly and in a satisfactory manner. The right is expressly reserved to reject any or all bids, to waive any informalities in the bids, or to accept such bids as appear to be in the best interest of the Town. Specifications may be obtained on the Town ·s website, www.greemvicbcl.om. It is the responsibility of the prospective bidder to check the website for any addenda issued up to 48 hours prior to the bid opening. Drawings and specifications will be posted to the Town's website and may be downloaded at no cost. Drawings taken from the Town's website and printed on the bidder's equipment may not be to scale. Full size hard c~ies of the drawings may be purchased from Greenwich Blueprint, LLC, 255 Greenwich Avenue, 2" floor, Greenwich, CT 06830, ph.
    [Show full text]
  • Performance-Based Specifications and Control of Concrete Durability This Publication Has Been Published by Springer in September 2015, ISBN 978-94-017-7308-9
    STAR 230-DUC Performance-Based Specifications and Control of Concrete Durability This publication has been published by Springer in September 2015, ISBN 978-94-017-7308-9. This STAR report is available at the following address: http://www.springer.com/978-94-017-7308-9 Please note that the following PDF file, offered by RILEM, is only a final draft approved by the Technical Committee members and the editors. No correction has been done to this final draft which is thus crossed out with the mention « Unedited version » as requested by Springer. RILEM TC 230-PSC Performance-Based Specifications and Control of Concrete Durability State-of-the-Art Report Please note that the Table of Contents of the unedited version doesn’t include Chapter 6 which was in LateX format and added later.version Page numbering is not correct. Unedited version Unedited Contents Contents i 1. Introduction 5 H. Beushausen 5 1.1 Background to the work of TC 230-PSC 5 1.2 Terminology 7 References 10 2. Durability of Reinforced Concrete Structures and Penetrability 11 L.-O. Nilsson, S. Kamali-Bernard, M. Santhanam 11 2.1 Introduction 11 2.2 Mechanisms Causing Reinforcement Corrosion 11 2.2.1 Carbonation 11 2.2.2 Chloride Ingress 12 2.3 Concrete Properties Relating to the Ingress of Aggressive Agents 12 2.3.1 Resistance against Diffusion of CO2 12 2.3.2 Moisture Transport Properties 14 2.3.3 Resistance against Chloride Diffusion and Convection 15 2.4 Service Life and Deterioration Models (Principles) 16 2.4.1 Carbonation Models, In Principle 17 2.4.2 Chloride Ingress Models, In Principle 18 2.4.3 Discussion on the Influence of Cracks version 19 References 19 3.
    [Show full text]
  • Taking the Mystery out of Mix Design in Part 1 of 2, Ken Hover Covers the Three Factors That Defi Ne a Concrete Mix
    INSIDE: CONCRETE SURFACES November/December 2019 An Offi cial Magazine of World of Concrete Taking the Mystery Out of Mix Design In Part 1 of 2, Ken Hover covers the three factors that defi ne a concrete mix. Pg 19 Pumping Dry Materials Pg 29 Installing a Thermal Break Pg 35 ONE-PASS POWERHOUSES When it comes to slab-on-grade, we’re talkin’ serious work ethic. Our award-winning boomed screeds are designed to help you do more with less. Make major efficiency gains ® on the projects where quality and reliability matter most. Come see these and our full line of Laser Screed® Machines at World of Concrete 2020 - BOOTH C5303. ® WWW.SOMERO.COM Get it Done. Get a Somero. or call 239.210.6519 CONTENTS November/December 2019 / Volume 64 / Number 7 19 Photo: Votorantim Cimentos/Prairie Materials FEATURES DEPARTMENTS 19 Taking the Mystery Out of Mix Design 5 Insider Information CS-41 Tie a Yellow Ribbon Learn how the various ingredients in a Come to WOC Again Sometimes the concrete mix come together in Part 1 of this only way to fi x two-part article. 10 Projects That Rock a bad polishing job A Formwork Challenge is to start over. 29 Material Placement Made Easy Fill and subgrade materials can be air-pumped 12 Business CS-45 Getting Consistent into inaccessible locations. Your Company’s Culture is Critical Results on Polished Concrete Overlays 35 Insulating Concrete Balconies 16 Uncommon Sense Follow these three steps for Structural thermal breaks are increasingly Leading Our Laborers a successful installation.
    [Show full text]
  • Workshop on Nanotechnology for Cement and Concrete September 5, 2007
    Workshop on Nanotechnology for Cement and Concrete September 5, 2007 Report of the Workshop on Nanotechnology for Cement and Concrete September 5, 2007 Peter Taylor Krishna Rajan Bjorn Birgisson Tom Cackler Sponsored by The National Concrete Pavement Technology Center and the National Science Foundation, in Cooperation with the Nanoscale Science, Engineering, and Technology (NSET) Subcommittee of the U.S. National Science and Technology Council, through the National Nanotechnology Coordination Office Acknowledgments The workshop was sponsored by The National Concrete Pavement Technology Center and the National Science Foundation, in Cooperation with the Nanoscale Science, Engineering, and Technology (NSET) Subcommittee of the U.S. National Science and Technology Council, through the National Nanotechnology Coordination Office. Travel support for most state department of transportation and university attendees and support for development of this report were made possible by NSF Grant CMMI 0749499. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the National Science Foundation. Thanks go to the presenters for permission to reproduce their presentations. I Workshop on Nanotechnology for Cement and Concrete Cement for on Nanotechnology Workshop I ii Preface This document summarizes the discussions and findings of a workshop held in Arlington, VA, on September 5, 2007. The objective of the meeting was to provide national direction on
    [Show full text]
  • Notice to Bidders, Specifications and Proposal
    145 Letting March 8, 2019 Notice to Bidders, Specifications and Proposal Contract No. 61F45 KANE County Section 16-00115-02-BR Route FAP 526 (Silver Glen Road) Project HILS-183 () District 1 Construction Funds Prepared by F Checked by (Printed by authority of the State of Illinois) NOTICE TO BIDDERS 1. TIME AND PLACE OF OPENING BIDS. Electronic bids are to be submitted to the electronic bidding system (iCX-Integrated Contractors Exchange). All bids must be submitted to the iCX system prior to 10:00 a.m. March 8, 2019 at which time the bids will be publicly opened from the iCX SecureVault. 2. DESCRIPTION OF WORK . The proposed improvement is identified and advertised for bids in the Invitation for Bids as: Contract No. 61F45 KANE County Section 16-00115-02-BR Project HILS-183 () Route FAP 526 (Silver Glen Road) District 1 Construction Funds Replace the bridge carrying Silver Glen Road over Otter Creek. 3. INSTRUCTIONS TO BIDDERS . (a) This Notice, the invitation for bids, proposal and letter of award shall, together with all other documents in accordance with Article 101.09 of the Standard Specifications for Road and Bridge Construction, become part of the contract. Bidders are cautioned to read and examine carefully all documents, to make all required inspections, and to inquire or seek explanation of the same prior to submission of a bid. (b) State law, and, if the work is to be paid wholly or in part with Federal-aid funds, Federal law requires the bidder to make various certifications as a part of the proposal and contract.
    [Show full text]
  • Effects of Concrete Moisture on Polymer Overlay Bond Over New Concrete
    Report No. K-TRAN: KSU-13-3 ▪ FINAL REPORT▪ June 2015 Effects of Concrete Moisture on Polymer Overlay Bond Over New Concrete Andrew Joseph Shearrer Kyle A. Riding, Ph.D., P.E. Robert J. Peterman, Ph.D., P.E. Kansas State University Transportation Center 1 Report No. 2 Government Accession No. 3 Recipient Catalog No. K-TRAN: KSU-13-3 4 Title and Subtitle 5 Report Date Effects of Concrete Moisture on Polymer Overlay Bond Over New Concrete June 2015 6 Performing Organization Code 7 Author(s) 7 Performing Organization Report Andrew Joseph Shearrer, Kyle A. Riding, Ph.D., P.E., Robert J. Peterman, Ph.D., No. P.E. 9 Performing Organization Name and Address 10 Work Unit No. (TRAIS) Kansas State University Transportation Center Department of Civil Engineering 11 Contract or Grant No. 2118 Fiedler Hall C1943 Manhattan, Kansas 66506 12 Sponsoring Agency Name and Address 13 Type of Report and Period Kansas Department of Transportation Covered Bureau of Research Final Report 2300 SW Van Buren August 2012–August 2014 Topeka, Kansas 66611-1195 14 Sponsoring Agency Code RE-0594-01 15 Supplementary Notes For more information write to address in block 9. Appendices are available in a separate PDF. http://ksdot1.ksdot.org/burmatrres/kdotlib2.asp or [email protected]. Epoxy polymer overlays have been used for decades on existing bridge decks to protect the deck and extend its service life. The polymer overlay’s ability to seal a bridge deck is now being specified for new construction. Questions exist about the amount of drying time needed to achieve an acceptable concrete moisture content to ensure an adequate bond to the polymer overlay.
    [Show full text]
  • Tio2 Photocatalysis in Portland Cement Systems: Fundamentals of Self Cleaning Effect and Air Pollution Mitigation
    TiO2 photocatalysis in Portland cement systems: fundamentals of self cleaning effect and air pollution mitigation By Andrea Folli, M. Sc., University of Milan, ITALY A thesis presented for the degree of Doctor of Philosophy at the University of Aberdeen Department of Chemistry University of Aberdeen 2010 Declaration I hereby declare that this thesis: 1. has been composed by Andrea Folli, i.e. the candidate for the degree of Doctor of Philosophy; 2. has not been accepted in any previous application for a degree; 3. has been entirely done by the candidate; 4. all quotations have been distinguished by quotation marks and the sources of information specifically acknowledged. Aberdeen, 13.10.2010 Andrea Folli Acknowledgements …da chimico un giorno avevo il potere di sposar gli elementi e farli reagire… ”Un chimico”, Fabrizio De André When I look back at the years of my PhD in Aberdeen I see without doubt one of the best periods of my life. Years of discovery: personal discovery above all. I discovered new characteristics and features about myself that I did not know existed. I discovered the thrill of jumping into an unknown culture without properly speaking the language. Along with the day by day quest of learning; learning how to integrate, learning how to handle situations and events far different from what I had learnt from my own culture, yet finding myself at home from the very first moment. I discovered how important it was to question myself and what I do, because my own reality holds its own perspective. I discovered that if I embrace any point of view, any different opinions and any critics I can abandon fear and open myself up to experience life at its greatest purpose.
    [Show full text]
  • Application with Self-Healing Concrete in Belgium: Analysis of the Laboratory Control Tests
    materials Article First Large Scale Application with Self-Healing Concrete in Belgium: Analysis of the Laboratory Control Tests Tim Van Mullem 1 , Elke Gruyaert 2, Robby Caspeele 1 and Nele De Belie 1,* 1 Magnel-Vandepitte Laboratory, Department of Structural Engineering and Building Materials, Faculty of Engineering and Architecture, Ghent University, Tech Lane Ghent Science Park, Campus A, Technologiepark Zwijnaarde 60, B-9052 Gent, Belgium; [email protected] (T.V.M.); [email protected] (R.C.) 2 Department of Civil Engineering, KU Leuven, Ghent Technology Campus, Gebroeders De Smetstraat 1, 9000 Ghent, Belgium; [email protected] * Correspondence: [email protected]; Tel.: +32-92645522 Received: 21 January 2020; Accepted: 20 February 2020; Published: 23 February 2020 Abstract: Due to the negative impact of construction processes on the environment and a decrease in investments, there is a need for concrete structures to operate longer while maintaining their high performance. Self-healing concrete has the ability to heal itself when it is cracked, thereby protecting the interior matrix as well as the reinforcement steel, resulting in an increased service life. Most research has focused on mortar specimens at lab-scale. Yet, to demonstrate the feasibility of applying self-healing concrete in practice, demonstrators of large-scale applications are necessary. A roof slab of an inspection pit was cast with bacterial self-healing concrete and is now in normal operation. As a bacterial additive to the concrete, a mixture called MUC+, made out of a Mixed Ureolytic Culture together with anaerobic granular bacteria, was added to the concrete during mixing.
    [Show full text]
  • Moisture Measurement in Concrete & Wood
    2010 NICFI Convention Moisture Measurement in Concrete and Wood Correct Usage and Application Moisture Sources precipitation dew point T-2 dew point T-1 ambient sub-slab RH vapor osmosis hydrostatic sub-slab water Picture Courtesy of CTLGroup Concrete Equilibrates with the Occupied Space Air Drier concrete moisture Wet Vapor retarder Sub-base When floor covering or coating is first applied, the moisture at the surface may still be OK, but… Floor covering Drier 75% 85% Wet 98% Shortly after the initial installation, the moisture in the slab will quickly equilibrate within the slab; bad news at the surface, and then… Slab Surface now wet 85% Floor covering 85% 85% Serious and Costly Failures and Damage Photos Courtesy CTLGroup, George Donnelly, CFI Drying Rate of Concrete • Rule-of-Thumb is minimum of 30 days of drying time per inch thickness of concrete to reach approximately 85% RH • Above assumes good drying conditions (HVAC on, no additional water, .40-.50 water/cement ratio) • Many factors can impact the minimum time • Even very old slabs can have high moisture Picture Courtesy of CTLGroup Why Measure Moisture? • Meet flooring manufacturer’s warranty requirements • Minimize potential IAQ problems • Minimize moisture-induced failures • Contractual obligation Basically, minimize liability and financial loss Approaches to Measuring Moisture QUALITATIVE-ONLY QUANTITATIVE • Plastic Sheet Test • Moisture Vapor Emission Rate • Mat Bond Test • Relative Humidity • Electrical Resistance moisture meters • Gravimetric (core sampling, lab analysis;
    [Show full text]
  • X” Are Applicable to This Contract and Are Included by Reference
    RECURRING SPECIAL PROVISIONS The following RECURRING SPECIAL PROVISIONS indicated by an “X” are applicable to this contract and are included by reference: CHECK SHEET # PAGE NO. 1 X Additional State Requirements for Federal-Aid Construction Contracts .............. 75 2 X Subletting of Contracts (Federal-Aid Contracts) .................................................. 78 3 X EEO ...................................................................................................................... 79 4 Specific EEO Responsibilities Non Federal-Aid Contracts .................................. 89 5 Required Provisions - State Contracts ................................................................. 94 6 Asbestos Bearing Pad Removal .......................................................................... 100 7 Asbestos Waterproofing Membrane and Asbestos HMA Surface Removal ........ 101 8 Temporary Stream Crossings and In-Stream Work Pads .................................... 102 9 Construction Layout Stakes Except for Bridges ................................................... 103 10 X Construction Layout Stakes ................................................................................. 106 11 Use of Geotextile Fabric for Railroad Crossing .................................................... 109 12 Subsealing of Concrete Pavements ..................................................................... 111 13 Hot-Mix Asphalt Surface Correction ..................................................................... 115 14 X Pavement and
    [Show full text]