Daikin One+ Commissioning Menu Outline for Unitary equipment, v2.0.2 software Display Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Default only? Conditions english spanish (radio buttons) english welcome french use large font (checkbox) (disabled) continue unitary single/multi-split (S21) (radio buttons) unitary equipment type VRV,SkyAir,single/multi- split (P1P2) continue

(to smart thermostat setup begin setup with 5 main steps below) setup factory reset run dealer demo mode setup options run homeowner demo mode learn more unitary mini/multi-split (S21) VRV will be supported in the equipment type unitary VRV,Skyair,mini/multi-split future. (P1P2) use wifi (list of available networks) Only appears when "use wifi" 1. Communication networks search again selected home wifi Only appears when connected connected to internet Yes to acive wifi network. connected to DaikinOne Only appears if successfully Yes Cloud connect to internet. english language francais english espanol (month, day, and year set automatically when connect build date selection) to WiFi. (hour, minute, and am/pm set automatically when connect date & time selection) to WiFi. use 24-hour format disabled set automatically when connect time zone (list of time zones) Pacific 2. Personalization to mobile app. main room upstairs downstairs hallway device name (text entry for other) main room bedroom kitchen other (other name) fahrenheit degree units fahrenheit celsius Model # Yes If scan successful Serial # Yes Control Software Version Yes

Specifications Inverter Software Version Yes Inverter only Number of cool stage Yes Will display for AC, as "0" Number of heat stages Yes stages. Tonnage Yes Low speed trim -15% to 15% in 3% increments Inverter AC only Air Conditioner (model # Intermediate speed trim Inverter AC only from CT) Cool Airflow Trim '-15% to 15% in 3% increments High speed trim '-15% to 15% in 3% increments Inverter AC only -10% to 10% in 2% increments 2-stage models only Profile A Profile B Cool Settings Cool Profiles Profile C Profile D Cool Airflow ON Delay 5, 10, 20, 30s Cool Airflow OFF Delay 30, 60, 90, 120s Max RPS Yes Inverter only Max RPS offset 0 to 20 in 0.5 RPS steps Inverter only Dehumidification Dehumidify with cooling: Off, On Model # Yes Serial # Yes Control Software Version Yes Specifications Inverter Software Version Yes Inverter only Number of cool stage Yes Number of heat stages Yes Tonnage Yes Low speed trim '-15% to 15% in 3% increments Inverter HP only Intermediate speed trim Inverter HP only Cool Airflow Trim '-15% to 15% in 3% increments High speed trim '-15% to 15% in 3% increments Inverter HP only -10% to 10% in 2% increments 2-stage models only Profile A Profile B Cool Settings Cool Profiles Profile C Profile D Cool Airflow ON Delay 5, 10, 20, 30s Cool Airflow OFF Delay 30, 60, 90, 120s Max compressor RPS Yes Inverter only (model # from Max RPS offset 0 to 20 in 0.5 RPS steps Inverter only CT) Dehumidification Dehumidify with cooling: Off, On Low speed trim '-15% to 15% in 3% increments Inverter HP only '-15% to 15% in 3% increments Heat Airflow Trim Intermediate speed trim Inverter HP only High speed trim '-15% to 15% in 3% increments Inverter HP only -10% to 10% in 2% increments 2-stage models only Heat Airflow ON Delay 5, 10, 15s HP only Heat Airflow OFF Delay 30, 50, 70, 90s HP only 1: always on; 2: on below 30°F; 3: 35°F; 4: Backup Defrost Heat 40°F; 5: 45°F; 6: 50°F; 7: 55°F; 8: 60°F; 9: Fit Heat Pump only Heat Settings 65°F; 10: always off; Defrost Interval 30, 60, 90, 120m HP only

Defrost Compressor Delay 0, 5, 15, 30s 2-stage HP only

Max compressor RPS Yes Inverter only

Max RPS offset 0 to 20 in 0.5 RPS steps Inverter only heat pump lockout temp If also electric or gas heat. -or- -20°F to 65°F in 5°F increments 15°F "balance point" is for dual-fuel balance point systems. Heat Pump Settings If also electric or gas heat, not aux heat lockout temp -10°F to 75°F in 5°F increments 50°F displayed for dual-fuel systems Model # Yes Serial # Yes

Specifications

Furnace (model # from CT)

3. Equipment Setup Control Software Version Yes Specifications number of stage Yes Size/Capacity Yes Blower Motor Size Yes -15% to 15% in 3% increments Modulating furnace only Gas Heat Airflow Trim -10% to 10% in 2% increments 2-stage furnace only Furnace (model # from Modulating and 2-stage Gas Heat Airflow ON Delay 5 to 30s in 5s increments CT) Heat Settings Modulating and 2-stage Gas Heat Airflow OFF Delay 30 to 180s in 30s increments furnaces Tap A Tap B Modulating and 2-stage Heat CFM Taps Tap C furnaces, not ULN furnace. Tap D 2-stage furnace only (not mod Humidification Mode On, Off Relay or ULN) 2-stage furnace only (not mod Humidification Speed 25, 50, 75, 100% or ULN) 2-stage furnace only (not mod Aux Alarm On/Off or ULN) Model # Yes Serial # Yes Specifications Control Software Version Yes Blower Motor Size Yes non-DVPEC/DVFEC (used to confirm heater kit installed Is a heater kit installed? Yes/No No 3. Equipment matching heater kit settings on Setup PCB). Yes non-DVPEC/DVFEC None, 3, 5, 6, 8, 10kW No DV25PEC, DV24FEC DV37PEC, DV36FEC, Size (kW) None, 5, 6, 8, 10, 15, 19kW No Heater Kit DV42FEC None, 5, 6, 8, 10, 15, 20kW No DV59PEC, DV48FEC None, 5, 6, 8, 10, 15, 20, 25kW No DV61PEC, DV60FEC DVPEC/DVFEC (EEV) models or Blower 0% to 10% in 2% steps (model # from CT) Electric Heat Airflow Trim only non-DVPEC/DVFEC CT models -10% to 10% in 2% steps (with TXV) Heat Airflow ON Delay Yes Heat Airflow OFF Delay Yes Humidifier Enable with Blower DVPEC/DVFEC only None On DVPEC/DVFEC only, if Humidifier Relay Humidification Mode Off humidifier selected in top menu

DVPEC/DVFEC only, if Humidification Fan Speed 25, 50, 75, 100% humidifier selected in top menu non-DVPEC/DVFEC air Aux Alarm On/Off handlers and blowers. Serial # Yes Coil (model # from CT) Configuration Software Version Yes Number of filters 1, 2 1 Media filter Do you want to remove this Cancel Remove equipment equipment? Continue sensor

If Mod or 2-stage furnace and 24V AC Condenser no AC or HP already. (ULN 1- stage furnace doesn't support.) Add Equipment Humidifier UV bulb Can only add 1 of each type. HEPA filter Electronic filter Zone board Indoor air quality Do you want to remove this Cancel Remove equipment sensor equipment? Continue

Cool CFM 18, 24, 30, 36, 42, 48, 60 kBTUs cooling

-15% to 15% in 3% increments Modulating furnace only Cool Airflow Trim -10% to 10% in 2% increments 2-stage furnace only

Profile A Profile B Cool Settings Cool Profiles 24V AC Condenser Profile C Profile D

5, 10, 20, 30s Modulating furnace only Cool Airflow ON Delay 1, 5, 10, 20, 30s 2-stage furnace only

Cool Airflow OFF Delay 30, 60, 90, 120s Modulating furnace only 0, 30, 60, 90, 120s 2-stage furnace only Do you want to remove this Cancel Remove equipment equipment? Continue Aux1 Connection Aux2 On with heat On with heat Control Humidifier On with heat and hum and hum call number of pads 1, 2 Do you want to remove this Cancel Remove equipment equipment? Continue Aux1 Connection Aux2 On with cool On with cool and dehum On with Control On with dehum dehum On with no cool and dehum Dehumidifier 0% 25% Fan speed 50% 100% 75% 100% Do you want to remove this Cancel Remove equipment equipment? Continue "0" means no equipment of this Number of bulbs 1, 2 0 UV Bulb type Do you want to remove this Cancel Remove equipment equipment? Continue "0" means no equipment of this Number of filters 1, 2 0 HEPA filter type Do you want to remove this Cancel Remove equipment equipment? Continue "0" means no equipment of this Number of filters 1, 2 1 Electronic filter type Do you want to remove this Cancel Remove equipment equipment? Continue Type EWC Zone Board

Zone Board 3. Equipment Setup

Zone 1 (radio button) Zone 1 Zone Board Additional Zone For air handlers, only if heater kit installed (checkbox) No "Additional Zone" selected. Do you want to remove this Cancel Remove equipment equipment? Continue Run test Only in inverter AC and HP for Stop first release. System Test (explanation of test) Run test If capable of cooling, and only Stop inverter AC/HP in first release. Charge Mode (explanation of test) Run test If system capabilities include Cooling Stop cooling (explanation of test) Run test Fan Stop Run test If system capabilities include Heat Pump Heat Stop heat pump heat. (explanation of test) Optional Tests Run test If system capabilities include Gas Heat Stop gas heat (explanation of test) Run test If system capabilities include Electric Heat Stop electric heat (explanation of test) Run test Pump Down Stop Inverter only, but not Fit AC/HP. (explanation of test) (date and time of error) Error History (code - equipment) Yes (error description) Clear error history? Cancel/Continue Yes/No Temperature calibration -7°F to 7°F in 1°F steps 0° Calibration calibration -15% to 15% in 1% steps 0% operation mode Yes all equipment current critical error Yes if critical error current minor error Yes if minor error requested heat demand Yes Only HP models. requested cool demand Yes all equipment requested indoor CFM Yes all equipment inverter always shows "0%", requested indoor fan demand Yes may only display for 2-stage where is valid. air conditioner requested dehum demand Yes all equipment compressor runtime Yes inverter only 4. System (or) heat pump compressor reduction mode Yes inverter only Optimization outdoor fan RPM Yes inverter only outdoor fan tap Yes inverter only outdoor air temp Yes all equipment outdoor coil temp Yes Not DX18 or DX16 models liquid temperatures Yes inverter only discharge temperature Yes inverter only outdoor defrost sensor temp Yes inverter HP only suction temperature Yes inverter only suction pressure Yes inverter only operation mode Yes current critical error Yes current minor error Yes current heat demand Yes requested heat demand Yes current indoor CFM Yes Status current indoor fan demand Yes requested indoor fan demand Yes requested hum demand Yes Won't display since always is air handler requested dehum demand Yes "0%". type Yes DVPEC/DVFEC only DVPEC/DVFEC only (may be calculated superheat Yes disabled) DVPEC/DVFEC only (may be calculated subcool Yes disabled) fan runtime Yes DVPEC/DVFEC only liquid temperature Yes DVPEC/DVFEC only suction temperature Yes DVPEC/DVFEC only pressure sensor Yes DVPEC/DVFEC only operation mode Yes current critical error Yes current minor error Yes current heat demand Yes requested heat demand Yes furnace current cool demand Yes requested cool demand Yes current indoor CFM Yes current indoor fan demand Yes requested indoor fan demand Yes requested hum demand Yes requested dehum demand Yes current critical error Yes EEV current minor error Yes 50°F min, min/max setpoints 50°F to 90°F in 1°F increments 90°F max

Temperature setpoint dead band: If system capabilities include 4°F (2°F to 9°F in 1°F increments) heating and cooling deadband / overcool cool/heat Overcooling allowed to dehumidify: If system capabilities include 0°F (0, 1, 2, or 3°F) cooling 16-18 and newer 20 SEER on/off inverter only boost mode Always ON, 70F, 75F, 80F, 85F, 90F, 95F, 16-18 and newer 20 SEER outdoor activation temperature 100F, 105F inverter only use quiet mode (check box) disabled Fit AC/HP only from: (time) to: (time) (time selection in 15 quiet hours 10pm to 7am Fit AC/HP only min. increments) Level 1 quiet mode Sound suppression level Level 2 Level 2 Fit AC/HP only Level 3 (quietest) house settings Capacity priority On/Off On Fit AC/HP only

5. Preferences house size 500 to 10,000 sf in 100 sqft increments Same level vertical rise Outdoor lower Inverter AC/HP Indoor lower name (text entry) phone (text entry) dealer information email (text entry) website (text entry) message (text entry)

media filter off, 1, 2, 3, 4, 6, or 12 months off if media filter

HEPA filter off, 1, 2, 3, 4, 6, or 12 months off if HEPA filter

reminders 5. Preferences

reminders Electronic filter off, 1, 2, 3, 4, 6, or 12 months off if Electronic filter UV bulbs off, 6, 12, 18, or 24 months off dehumidification filter off, 1, 3, 6, or 12 months off humidifier pad off, 3, 6, or 12 months off service reminder off, 3, 6, or 12 months off