Daikin One+ Thermostat Commissioning Menu Outline For
Total Page:16
File Type:pdf, Size:1020Kb
Daikin One+ Thermostat Commissioning Menu Outline for Mini/multi-split (S21) equipment, v2.0.2 software Display Level 1 Level 2 Level 3 Level 4 Level 5 Default only? Conditions english spanish (radio buttons) english welcome french use large font (checkbox) (disabled) continue unitary single/multi-split (S21) (radio buttons) unitary equipment type VRV,SkyAir,single/multi-split (P1P2) continue (to smart thermostat setup begin setup with 5 main steps below) setup factory reset setup options run dealer demo mode run homeowner demo mode learn more unitary equipment type mini/multi-split (S21) unitary VRV, SkyAir, mini/multi-split (P1/P2) VRV will be supported in the future. use wifi 1. Communication (list of available networks) networks search again Only appears when "use wifi" selected home wifi Only appears when connected to acive wifi connected to internet Yes network. connected to DaikinOne Only appears if successfully connect to Cloud Yes internet. english language francais english espanol (month, day, and year build date set automatically when connect to WiFi. selection) (hour, minute, and am/pm set automatically when connect to WiFi. date & time selection) use 24-hour format disabled time zone (list of time zones) Pacific set automatically when connect to mobile app. 2. Personalization main room upstairs downstairs hallway (text entry for other) main room device name bedroom kitchen other (other name) fahrenheit fahrenheit degree units celsius Indoor Unit: (model #) (pick from list) (description based on model number) edit (text entry) Indoor Unit: (model #) Serial #: (text entry) wall-mount Set automatically when model number ceiling cassette selected from list. Default allows manual unit type Maybe single-flow cassette entry, also allowed if manually entered model floor-mount number. Outdoor Unit: (model #) (pick from list) (description based on model Outdoor Unit: (model #) number) edit (text entry) Serial # (text entry) 3. Equipment Number of filters 1, 2 1 Standard filter Do you want to remove Setup Remove equipment Yes/No this equipment? indoor air quality sensor Add Equipment Can only add 1 of each type. HEPA filter Filter box Do you want to remove Cancel Remove equipment Indoor air quality sensor this equipment? Continue Number of filters 1, 2 0 HEPA filter Do you want to remove Cancel Remove equipment this equipment? Continue Number of filters 1, 2 0 Filter box Do you want to remove Cancel Remove equipment this equipment? Continue (date and time of error) (code - Indoor Unit #) Error History (error description) (minor error code) Clear error history? Cancel/Continue Yes/No Temperature calibration -7°F to 7°F in 1°F steps 0°F Calibration Humidity calibration -15% to 15% in 1% steps 0% 4. System Optimization EEV open degree (pulse) Emura only outdoor air temp Emura only heat exchanger temp Emura only Outdoor unit discharge temperature Emura only Status liquid pipe temp Emura only outdoor fan RPM Emura only power consumption Emura only electric current Emura only Indoor unit indoor suction temp Emura only therm on/off Emura only heating: 57 to 86 min/max setpoints 57°F to 90°F 57°F to 90°F cooling: 64 to 90 Temperature setpoint 2°F to 9°F in 1°F steps 4°F dead band: deadband / overcool Overcooling allowed to 0°F to 3°F in 1°F steps 0°F dehumidify: 1, 2, 3, 4°F cool/heat 1°F start timer diff (0.5, 1, 1.5, 2.0°C) changeover settings 5. Preferences cool/heat 1, 2, 3, 4°F 1°F Must be >= to start timer diff forced changeover diff (0.5, 1, 1.5, 2.0°C) changeover settings Timer started on heat-to-cool or cool-to-heat 0 to 60 min. in 15 min. transition so doesn't change modes too 0 5. Preferences steps quickly. Timer is ignored if forced changeover changeover timer diff is reached. 500 to 10,000 sf in 100 sf House size house settings steps dealer information name (text entry) phone (text entry) email (text entry) website (text entry) message (text entry) Standard filter off, 1, 2, 3, 4, 6, or 12 off if added in "add equipment" off, 1, 2, 3, 4, 6, or 12 HEPA filter off if added in "add equipment" reminders months Filter box off, 1, 2, 3, 4, 6, or 12 off if added in "add equipment" service reminder off, 3, 6, or 12 months off.