It should come as no surprise that a company that has built its reputation on concept of innovation, continues to lead the industry with the broadest—and, yes, the most innovative selection of water heaters and hot water supply boilers in its long and storied history. What might come as a surprise to some is the fact that view this accomplishment as a mere beginning—an indication of even greater things still to come. For everyone here at A. . Smith, it’s never been just about exceeding what we had achieved in the past—it’s always been about exceeding everyone’s expectations for the future. Which is why you, our customers, can count on us to provide you with the perfect water heater solution for any application—day after day, year after year. Table of Contents Innovation Continues to Lead...... 2 Gas Water Heaters ...... 3–10 Tankless ...... 11 Powered Burner Gas Water Heaters ...... 12–14 Oil-Fired Water Heaters ...... 15–17 Electric Water Heaters ...... 18–23 Circulating Water Heaters & Hot Water Supply Boilers . . . . 24–33 Electric Boilers & Hot Water Generators ...... 34–35 Storage Tanks ...... 36–37 iCOMM™ Remote Monitoring System...... 38 Building Management System BACnet and MODBUS Interface. . .39 Commercial Line Overview and Support Network...... 40–41 C.J. Smith A. O. Smith Launches Cyclone® establishes Patents the the Cyclone® Mxi the company glass-lined Commerical Launch water Water Heater heater

Provides fully modulating combustion to precisely meet demands. Exclusive advanced LCD electronic control, with built-in diagnostics.

Top mounted components include new spark ignition, quiet operation burner and blower combination.

Enhanced PermaGlas®

glass lining process that provides superior tank protection against corrosion.

For more information, please visit

4 www.hotwater.com GAS WATER HEATERS 80% thermal efficient - approved for Conservationist® use in combined appliance applications. Power Vent BTF Model

CFC-Free Foam Insulation Enhanced-Flow Brass n Minimizes radiant heat loss Drain Valve n Solid brass, tamper resistant, Dip Tube ® enhanced-flow, ball type drain C.J. Smith A. O. Smith Launches Cyclone n Carries inlet water deep ® valve establishes Patents the the Cyclone Mxi into tank n the company glass-lined Commerical Launch Uses a standard female hose water Water Heater fitting that allows for fast heater Hot Surface Ignition and easy draining during n Solid state ignition maintenance surface that does not n Designed for easy operation, flutter or blow out this valve includes an integral n Provides increased reliability and screwdriver slot that features a efficiency over spark ignition ¼ turn (open/close) radius, which systems not only permits full straight- n Eliminates the pilot and saves through water flow but also a energy quick and positive shut off User-Friendly Powered Venting n State-of-the-art electronic gas n Provides more venting flexibility control provides more precise and savings. A new quiet temperautre control blower allows exhaust venting n LED control light displays through the roof or sidewall operation status and diagnostic with plastic pipe such as ULC information S636 PVC, CPVC or polypropylene n Up to 125 equivalent feet of ® Provides fully modulating Blue Diamond Glass Coating pipe makes installation easy in combustion to precisely n Provides superior corrosion any situation resistance compared to the n BTF-80 is a Category 3 (positive meet demands. industry standard glass lining pressure non-condensing)

Exclusive advanced LCD appliance electronic control, with Anode n Factory-Installed built-in diagnostics. Tank-mounted, screw-in magnesium anode for Temperature and Pressure longer tank life Relief Valve Top mounted components High-Input n Properly sized for each model (Specify if your local code include new spark ignition, n 76,000 BTU input assures requires a special T&P) LOW LEAD quiet operation burner plenty of hot water is CONTENT available by providing 3-Year Limited Tank/1-Year and blower combination. faster recovery rates and Limited Parts Warranty higher first hour draws

Enhanced PermaGlas® Burner glass lining process n High-input, multi-port burner for improved combustion that provides superior efficiency tank protection MAXIMUM RECOVERY APPROX. CAPACITY INPUT CERTIFIED 100°F (56°C) HEIGHT DIAMETER SHIPPING against corrosion. MODEL USG (L) BTU/h ALTITUDE TEMP. RISE IN (CM) IN (CM) WEIGHT FT (M) GPH (LPH) LB (KG)

5 BTF-80 75 (284) 76,000 10,100 (3,078) 74 (280) 70 /8 (179) 26 (66) 277 (126)

For more information, please visit www.hotwater.com 5 GAS WATER HEATERS Conservationist® Atmospheric 80% thermal efficiency, ideal for Vent BT Models light-duty applications.

BT models provide reliable, efficient service for light-duty applications such as office buildings and duplex/fourplex apartment homes.

Heavy Gauge Steel Jacket n­­ Finished with baked enamel over bonderized undercoat Glass-Lined Tank n Protects steel tank from corrosion and maximizes tank life Fully Automatic Controls with Safety Shut Off n Accurate, dependable control system requires no electric connections n Fixed automatic gas shut off device for added safety n Temperature adjustable up to 181°F Draft Diverter n Low profile diverter furnished as standard equipment Hand Hole Clean Out n Allows for easy tank cleaning Foam Insulation n Saves fuel and helps reduce standby heat loss Maximum Working Pressure n LOW LEAD 150 CONTENT Maximum Gas Inlet Pressure n 14” W.C. Codes and Standards n All models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 n CSA certified and ASME rated T&P relief valve n Not recommended for sanitation rinse 3-Year Limited Tank/1-Year Limited Parts Warranty

MAXIMUM APPROX. RECOVERY CAPACITY INPUT CERTIFIED HEIGHT DIAMETER SHIPPING MODEL 100°F (56°C) TEMP. RISE USG (L) BTU/h ALTITUDE IN (CM) IN (CM) WEIGHT GPH (LPH) FT (M) LB (KG)

1 1 8 2 BT-80 74 (280) 75,100 7,700 (2,347) 73 (275) 61 / (155) 26 / (67) 275 (125) 5 3 BT-100 98 (371) 75,100 7,700 (2,347) 73 (275) 68 /8 (174) 27 /4 (71) 350 (159)

6 GAS WATER HEATERS 80% thermal efficiency, Master-Fit® Atmospheric Vent self-cleaning, easy-to-install. BTRC Models

Factory-Installed Draft Diverter Fully Automatic Control System and Flue Damper (BTRC 120-400 n Manual reset gas shut off models) device prevents excessive water n Low-profile draft diverter helps temperature for installation in tight spaces n Adjustable thermostat with n Automatic motorized flue 120ºF–180ºF range damper helps minimize standby n Gas pressure regulator and pilot heat loss filter n BTRC 500 model features induced draft design and no Hand Hole Clean Out damper  n Allows easy access to tank Water Connections interior for cleaning n For ease of installation, Category Appliance most models feature water n Can commonly vented connections on the front, top or with other Category I rear of unit appliances, using standard PermaGlas® Ultra Coat™ metal type “B” vent Glass Lining n Optional power vent kits n Exclusive process provides available to allow sidewall superior protection venting up to 100 against corrosion equivalent feet n Applied after tank construction, BTRC 120-200 P/N 197515-000; the tank is mechanically BTRC 250-500 P/N 197515-001 maneuvered to ensure the liquid glass covers all surfaces for Eliminator™ Self Cleaning superior protection System n ™ Directs incoming cold water CoreGard Anode Rod to sweep the bottom of the n Stainless steel core provides tank so sediment does not additional corrosion protection accumulate Codes and Standards n Reduced sediment build- n All models meet the thermal up maintains rated thermal LOW LEAD efficiency and standby loss efficiency and reduces CONTENT requirements of NRCan and current water heating costs edition of ASHRAE/IESNA 90.1

Factory-Installed, CSA Certified HLW and ASME Rated T&P Relief Valve 3-Year Limited Tank/1-Year On Select Models n Properly sized for each model Limited Parts Warranty Approved to NSF Standard 5 with Optional Leg Kit

APPROX. RECOVERY VENT CAPACITY INPUT HEIGHT* DIAMETER SHIPPING WEIGHT MODEL 100°F (56°C) TEMP. RISE DIAMETER USG (L) BTU/h IN (CM) IN (CM) LB (KG) GPH (LPH) (IN) STD ASME

3 3 BTRC-120 71 (268) 120,000 116 (439) 5 69 /4 (177) 27 /4 (71) 512 (232) -

3 BTRC-154 81 (307) 154,000 149 (564) 6 73 (185) 27 /4 (71) 552 (250) -

3 BTRC-180 76 (288) 180,000 174 (659) 6 67 ½ (171) 27 /4 (71) 576 (261) -

3 BTRC-197 95 (360) 199,000 193 (731) 6 75 (191) 27 /4 (71) 645 (293) -

3 BTRC-199 76 (288) 199,000 193 (731) 6 67 ½ (171) 27 /4 (71) 592 (269) -

1 BTRC-200A 100 (379) 199,000 193 (731) 6 72 (183) 30 /4 (77) - 715 (324)

1 BTRC-250A 100 (379) 250,000 242 (916) 8 72 (183) 30 /4 (77) - 715 (324)

3 BTRC-251(A) 65 (246) 251,000 243 (920) 8 75 (191) 27 /4 (71) 660 (299) 661 (300)

1 BTRC-275A 100 (379) 275,000 267 (1,011) 8 72 (183) 30 /4 (77) - 721 (327)

3 BTRC-305(A) 65 (246) 305,000 296 (1,120) 8 75 (191) 27 /4 (71) 659 (299) 672 (305)

3 BTRC-365(A) 65 (246) 365,000 349 (1,321) 8 79 ½ (202) 27 /4 (71) 670 (304) 661 (300)

1 1 BTRC-400A 100 (379) 390,000 387 (1,465) 8 75 /2 (192) 30 /4 (77) - 844 (383)

3 BTRC-500A 85 (322) 500,000 479 (1,813) 8 81 ½ (207) 27 /4 (71) - 824 (374) (A) - Available with ASME tank construction * Height to top of drafthood High altitude models also available. 7 GAS WATER HEATERS Cyclone® MXi Modulating Modulating burner advances the BTH Gas Models Cyclone to higher levels of efficiency.

The full line of A. O. Smith Cyclone MXi condensing water heaters have been designed to provide years of dependable service and feature industry leading technology. Models are available from 120,000 to 500,000 BTU/h and all deliver thermal efficiencies of 95% and higher. The unique helical coil heat exchanger limits weld joints for optimal service life while maximizing heat transfer. Cyclone is the industry leader in high efficiency commercial water heating with over a quarter million sold since 1996. The MXi modulating models adjust firing rate to the specific demand further increasing efficiency and money savings.

Submerged Combustion Chamber with Helical Heat Exchanger Coil n Positioned in center of tank, surrounded by water to virtually eliminate radiant heat loss from chamber n Direct spark ignition for years of worry free operation n Spiral heat exchanger keeps hot burner gases swirling and uses centrifugal force to maximize efficiency of heat transfer to water in tank n Spiral heat exchanger reduces lime scale from forming on water-side surfaces, which maintains energy efficiency over time Intelligent Control System with LCD Display n Exclusive A. O. Smith designed control system n Provides detailed water heater status information n Precise temperature control adjustable from 90°F to 180°F n Built-in diagnostics n Run history information n iCOMM™ compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information n Connect to an existing building management system via BACnet or MODBUS with optional ICC gateway

Powered Anodes Standard on All Models ANSl/NSF-5 n Provides long-lasting tank protection in varying water conditions n Powered anodes are non-sacrificial n Automatically adjusts output needed to properly 1.888. WATER02 protect the tank

8 GAS

Cyclone® MXi Modulating WATER HEATERS BTH Gas Models

Mechanical Venting Versatility n  Flexibility of conventional power venting or direct venting vertically or through a sidewall

n  For added flexibility, easy install and access, the exhaust and condensate connections are located in the front of the heater

n  Installations require ULC S636 PVC, CPVC, polypropylene or AL29-4C® stainless steel pipe for intake and exhaust

PermaGlas® Ultra Coat™ Glass Lining n Glass coating is applied using a liquid slush coating technique to ensure uniform coating n Heat exchanger coil is glassed both externally and internally for optimum protection High Efficiency Modulating Pre-Mix Powered Burner n Down-fired pre-mix burner provides optimum efficiency and quiet operation n Top-mounted burner position prevents condensation from affecting burner operation Space-Saving Design for Installation Flexibility n Reduced footprint, ease of service, protection from water damage in case of flooding n Easy to remove top cover for convenient access to serviceable parts n 0” installation clearances on sides and rear, 1-1/2” installation clearance on top, 4” alcove installation clearance in front hand hole clean out of unit n Hand hole clean out allows easy access to tank interior for cleaning n 0” clearance to combustibles, approved for installation on combustible floors 3-Year Limited Tank/1-Year Limited Parts Warranty

RECOVERY APPROX. VENT CAPACITY INPUT 100°F (56°C) HEIGHT DIAMETER SHIPPING WEIGHT MODEL DIAMETER USG (L) BTU/h TEMP. RISE IN (CM) IN (CM) LB (KG) (IN) GPH (LPH) STD ASME BTH-120(A) 60 (227) 120,000 138 (523) 3, 4 55 ½ (141) 27 ¾ (71) 460 (208) 490 (220) BTH-150(A) 100 (379) 150,000 178 (674) 3, 4 76 ½ (195) 27 ¾ (71) 523 (237) 553 (251) BTH-199(A) 100 (379) 199,000 235 (890) 3, 4 76 ½ (195) 27 ¾ (71) 523 (237) 553 (251) BTH-250(A) 100 (379) 250,000 291 (1,101) 3, 4 76 ½ (195) 27 ¾ (71) 523 (237) 553 (251)

1 BTH-300A 119 (451) 300,000 349 (1,321) 4, 6 75 ¾ (192) 33 /8 (84) - 855 (387)

1 BTH-400A 119 (451) 399,900 460 (1,743) 4, 6 75 ¾ (192) 33 /8 (84) - 855 (387)

1 BTH-500A 119 (451) 499,900 576 (2,179) 4, 6 75 ¾ (192) 33 /8 (84) - 855 (387) (A) -Available with ASME tank construction

9 GAS WATER HEATERS Cyclone® Xi™ Available up to 96% thermal efficiency, BTX and BTXL Gas Models venting flexibility, outstanding value.

The Cyclone Xi is a light-duty, power direct vent, fully condensing commercial gas water heater with an internal helical heat exchanger. This helical heat exchanger helps Cyclone Xi achieve 96% thermal efficiency and deliver outstanding hot water output.

ENERGY STAR® Qualified Submerged Combustion Chamber, with Helical Heat Exchanger Coil n Positioned in center of tank, surrounded by water to virtually eliminate radiant heat loss from chamber n Spiral heat exchanger reduces the accumulation of lime scale, to help maintain higher efficiency performance over time PermaGlas® Ultra Coat™ Glass Lining n Exclusive process provides superior corrosion protection n Both sides of heat exchanger coil are lined for protection against flue gas condensate inside coil Advanced Electronic Control System with LCD Display n iCOMMTM compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information n Precise temperature control n Connect to an existing building management system via BACnet or MODBUS with optional ICC gateway n Built-in diagnostics Venting Options 1.888. WATER02 n Uses inexpensive ULC S636 PVC, CPVC or polypropylene pipe vertically through the roof or horizontally through the wall (see instruction manual for complete venting instructions and allowable vent lengths) n Optional concentric vent and sidewall termination kits available Side-Mounted Hot and Cold Recirculating Taps n Allows Cyclone Xi to be installed as part of combination space heating/water heating applications n Plugs for the recirculating taps are factory installed 3-Year Limited Tank/1-Year Limited Parts Warranty

MAXIMUM APPROX. RECOVERY 100°F VENT CAPACITY INPUT CERTIFIED HEIGHT DIAMETER SHIPPING MODEL (56°C) TEMP. RISE DIAMETER USG (L) BTU/h ALTITUDE IN (CM) IN (CM) WEIGHT GPH (LPH) (IN) FT (M) LB (KG) BTX-100 50 (189) 100,000 10,100 (3,078) 116 (439) 2, 3 66 ¾ (170) 22 (56) 255 (116)

3 BTXL-100 75 (284) 100,000 10,100 (3,078) 116 (439) 2, 3 65 ¼ (166) 27 /4 (71) 382 (173)

10 GAS WATER HEATERS 76,000 BTU, 90% Cyclone® HE™ BTX-80 thermal efficiency.

The 50-gallon light-duty power vent Cyclone HE is designed to produce more hot water than any commercial gas water heater in its class. Thanks to the internal helical heat exchanger—similar to the design of the industry- leading Cyclone MXi and Xi™ models—the unit achieves 90% thermal efficiency. With its small footprint and easy installation, the Cyclone HE delivers heavy-duty performance for light-duty applications, making it the perfect choice for restaurants, offices and other light-duty applications.

Helical Coil Heat Exchanger n Submerged heat exchanger provides much greater heat transfer surface than standard straight flue tube n Produces 90% thermal efficiency, which saves money on operating costs and increases hot water output compared to standard-efficiency water heaters Versatile Power Vent Design n System allows combined vertical and horizontal vent runs using ULC S636 PVC or CPVC pipe Modular Blower n PVC Vent Attenuation Assembly (VAA) supplied for applications where extra-quiet operation is essential n Condensate drain supplied High-Output with Small Footprint n 22˝ diameter, combined with 90% efficiency and 76,000 BTU input means the Cyclone HE can be installed in less

space than a larger 75-gallon unit with equal or better LOW LEAD CONTENT performance Blue Diamond® Glass Coating n Provides superior corrosion resistance compared to industry standard glass lining

Intelli-Vent™ * Gas Control n Equipped with long-lasting silicon nitride hot surface igniter—no standing pilot n Advanced electronics for more precise control of water temperature and simplified system diagnostics n 181°F maximum temperature setting Side-Mounted Hot and Cold Recirculating Taps n Allows Cyclone HE to be installed as part of combination space heating/water heating applications, or any system requiring a recirculating hot water loop n Plugs for the recirculating taps are factory-installed Two Heavy-Duty Anode Rods n Provide advanced corrosion protection­

*Intelli-Vent™ is a trademark of Emerson Electric Company

11 GAS WATER HEATERS

Superior Heat Transfer By utilizing the innovative internal heat exchanger coil, the Cyclone® HE™ provides superior heat transfer capabilities, resulting in an unprecedented 90% thermal efficiency, far beyond a standard water heater design. Gallon for gallon, the Cyclone HE will heat water for significantly less, resulting in substantial savings on energy costs. With as much power as larger water heaters in a standard 50-gallon footprint, the Cyclone HE is the natural choice for upgrading during a renovation. And the versatile power vent design allows combined vertical and horizontal vent runs of up to 128 equivalent feet. Cyclone HE provides superior savings on energy costs.

RECOVERY APPROX. CAPACITY INPUT 100°F (56°C) HEIGHT DIAMETER SHIPPING MODEL USG (L) BTU/h TEMP. RISE IN (CM) IN (CM) WEIGHT The classic Cyclone helical heat exchanger coil GPH (LPH) LB (KG)

delivers 90% thermal efficiency. 1 BTX-80 50 (189) 76,000 83 (314) 71 / 8 (180) 22 (56) 210 (95)

SUGGESTED SPECIFICATION Natural Gas water heater(s) shall be A. O. Smith Cyclone® HE™ model BTX-80, with 90% thermal efficiency, a storage capacity of 50 gallons, an input rating of 76,000 BTU per hour, a recovery rating of 83 gallons per hour at 100ºF rise and a maximum hydrostatic working pressure of 150 psi. Water heater(s) shall be of power vent design ­ using 2˝, 3˝ or 4˝ ULC S636 PVC or CPVC pipe for horizontal and/or vertical vent runs.

3-Year Limited Tank/1-Year Limited Parts Warranty

12 GAS WATER HEATERS Endless hot water*. Compact Size. Tankless Models Energy Conservation.

A. O. Smith commercial tankless water heaters will provide a steady flow of hot water for as long as your application needs it in the most energy efficient way possible. Because our tankless water heaters only activate when hot water is being used, no standby energy losses are incurred providing efficient heating and conserving gas energy. On top of all this, an A. O. Smith tankless water heater takes up much less space than conventional tank-type water heaters or boilers allowing for additional storage space and flexibility.

Commercial Grade Copper Heat Exchanger n Stronger than regular copper (C1220) and transfers heat faster than stainless steel n Resilient against erosion Energy Efficient n Units only heat the water being used so there is no standby energy loss n 540H condensing model is ENERGY STAR® qualified

Venting Flexibility (Condensing Only) n Metal vent collar for PVC with no gluing or cutting n Approved with ULC S636 PVC, CPVC, polypropylene or Cat. III/IV stainless steel pipe Non-Condensing Concentric Vent n Vents with contractor-preferred concentric venting n Field convertible from natural gas to propane out of the box Multiple Unit Installation n Easy Link – Up to 4 units with no additional accessories n Multi Link – Up to 20 540H and 510C units with TM-MC02 system controller (10 units with 910 model) Dual Internal Freeze Protection

10-Year Limited Heat Exchanger/5-Year Limited Parts Warranty C US

APPROX. ENERGY FACTOR/ INPUT FLOW RATE HEIGHT WIDTH DEPTH SHIPPING MODEL THERMAL BTU/h GPM IN (CM) IN (CM) IN (CM) WEIGHT EFFICIENCY MINIMUM MAXIMUM 30°F RISE 70°F RISE LB (KG) CONDENSING

3 ATI-540H 13,000 199,000 0.95 10.0 5.4 22 ½ (57) 17 /4 (45) 10 ¾ (27) 58 (26) NON-CONDENSING

1 ATI-510 11,000 199,000 0.82 10.0 4.7 20 /4 (52) 13 ¾ (35) 9 ½ (24) 39 (18) ATI-510C 15,000 199,000 0.82 10.0 4.7 20 ½ (52) 13 ¾ (35) 10 ½ (27) 51 (23)

1 7 ATI-910(A) 15,000 380,000 80% (NG) 82% (LP) 14.5 8.7 25 /4 (64) 24 /8 (63) 12 ¼ (31) 112 (51)

(A) – ASME version available

*When sized appropriately.

13 GAS WATER HEATERS Large Volume Power Burner BTP-150-140 through BTP Gas Models BTP-600-2500.

The high-volume powered burner line includes the largest, most powerful A. O. Smith tank-type gas water heaters. With tank capacities up to 600 gallons and firing capacities up to 2.5 million BTU per hour, these large-volume high-output water heaters are capable of producing over 3,000 gallons of hot water per hour at an 80°F rise. These heavy-duty industrial- grade water heaters are designed and built to handle the most demanding hot water heating requirements of large commercial and industrial users.

Powered Gas Burner n Suitable for natural or propane gas n Electronic flame safeguard control with intermittent spark ignition n Main and pilot automatic gas valves with gas pressure regulators n Diaphragm air switch for proof of blower operation n Flame inspection port Fully Automatic Controls with Safety Shut Off n High temperature limit control (manual reset) n ASME-rated T&P valve n Hinged door control compartment for easy access n Upper and lower thermostats for accurate temperature control n Standard control is for 120°F-180°F water service n Factory-installed low water cut off

Blue Diamond® Glass Lining n Proprietary A. O. Smith glass lining provides superior HLW LOW LEAD CONTENT coverage and unmatched durability n Equipped with multiple anode rods for additional corrosion protection Heavy-Duty Jacket n Heavy gauge steel jacket with baked powder coated finish for durability n Two 3˝ hand hole inspection openings Maximum Hydrostatic Working Pressure n 160 psi for all models Professional Start-Up Service n Assures proper installation and adjusts burner for clean combustion and most efficient operation Codes and Standards n Design-certified by UL (Underwriters Laboratories), according to ANSI Z21.10.3 - 4.3 CSA standards n All models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1

­ 1414 GAS WATER HEATERS All models are approved for use in combined appliance applications.

Other BTP Features 3-Year Limited Tank/1-Year Limited Parts n Two layers of high-temperature ceramic fiber Warranty insulation in combustion chamber n For complete information, consult written n Mounted on rugged channel iron skids warranty or contact A. O. Smith n National board stamping n Barometric draft regulator BTP Options n n 120V control circuit Factory mutual approved control arrangement n n Drain valve High or low water pressure switch n n 180°F water service thermostats Modular graphic burner systems management on heaters with 270,000 BTU/h input and over

FIRST APPROX. RECOVERY VENT CAPACITY INPUT HOUR MOTOR HP 120V HEIGHT DIAMETER DEPTH SHIPPING MODEL 100°F (56°C) TEMP. RISE DIAMETER USG (L) BTU/h RATING 60 Hz 1 PHASE IN (CM) IN (CM) IN (CM) WEIGHT GPH (LPH) (IN) GPH (LPH) LB (KG)

1 1 BTP-150-140 150 (568) 140,000 256 (969) 136 (515) 1/15 HP 2.2 AMPS 5 84 /2 (215) 36 /2 (93) 48 (122) 1,292 (586)

1 1 BTP-150-199 150 (568) 199,000 313 (1,185) 193 (731) 1/15 HP 2.2 AMPS 6 84 /2 (215) 36 /2 (93) 48 (122) 1,292 (586)

1 1 BTP-150-255 150 (568) 255,000 367 (1,389) 247 (935) 1/15 HP 2.2 AMPS 6 84 /2 (215) 36 /2 (93) 48 (122) 1,292 (586)

1 1 1 BTP-150-270 150 (568) 270.000 382 (1,446) 262 (992) 1/4 HP 4.6 AMPS 6 84 /2 (215) 36 /2 (93) 58 /2 (149) 1,397 (634)

1 1 1 BTP-150-400 150 (568) 400,000 507 (1,919) 387 (1,465) 1/4 HP 4.6 AMPS 7 84 /2 (215) 36 /2 (93) 58 /2 (149) 1,397 (634)

1 1 1 BTP-150-540 150 (568) 540,000 644 (2,438) 524 (1,984) 1/4 HP 4.6 AMPS 8 84 /2 (215) 36 /2 (93) 58 /2 (149) 1,505 (683)

1 1 1 BTP-150-720 150 (568) 720,000 818 (3,096) 698 (2,642) 1/3 HP 5.5 AMPS 10 84 /2 (215) 36 /2 (93) 58 /2 (149) 1,510 (685)

1 3 1 BTP-200-300 200 (757) 300,000 451 (1,707) 291 (1,102) 1/4 HP 4.6 AMPS 6 83 /2 (212) 44 /4 (114) 67 /2 (171) 2,098 (952)

1 3 1 BTP-200-600 200 (757) 600,000 742 (2,809) 582 (2,203) 1/4 HP 4.6 AMPS 8 83 /2 (212) 44 /4 (114) 67 /2 (171) 2,098 (952)

1 3 1 BTP-200-800 200 (757) 800,000 936 (3,543) 776 (2,937) 1/3 HP 5.5 AMPS 10 83 /2 (212) 44 /4 (114) 67 /2 (171) 2,103 (954)

1 3 1 BTP-200-1000 200 (757) 1,000,000 1,130 (4,278) 970 (3,672) 1/3 HP 5.5 AMPS 10 83 /2 (212) 44 /4 (114) 67 /2 (171) 2,103 (954)

1 3 1 BTP-200-1250 200 (757) 1,250,000 1,372 (5,194) 1,212 (4,588) 1/2 HP 7.4 AMPS 12 83 /2 (212) 44 /4 (114) 67 /2 (171) 2,467 (1,119)

1 3 1 BTP-200-1500 200 (757) 1,500,000 1,615 (6,113) 1,455 (5,508) 1/2 HP 7.4 AMPS 12 83 /2 (212) 44 /4 (114) 67 /2 (171) 2,675 (1,213)

1 3 1 BTP-300-300 300 (1,136) 300,000 531 (2,010) 291 (1,102) 1/4 HP 4.6 AMPS 6 91 /2 (232) 44 /4 (114) 67 /2 (171) 2,150 (975)

1 3 1 BTP-300-600 300 (1,136) 600,000 822 (3,112) 582 (2,203) 1/4 HP 4.6 AMPS 8 91 /2 (232) 44 /4 (114) 67 /2 (171) 2,150 (975)

1 3 1 BTP-300-800 300 (1,136) 800,000 1,016 (3,846) 776 (2,937) 1/3 HP 5.5 AMPS 10 91 /2 (232) 44 /4 (114) 67 /2 (171) 2,308 (1,047)

1 3 1 BTP-300-1000 300 (1,136) 1,000,000 1,210 (4,580) 970 (3,672) 1/3 HP 5.5 AMPS 10 91 /2 (232) 44 /4 (114) 67 /2 (171) 2,308 (1,047)

1 3 1 BTP-300-1250 300 (1,136) 1,250,000 1,452 (5,496) 1,212 (4,588) 1/2 HP 7.4 AMPS 12 91 /2 (232) 44 /4 (114) 67 /2 (171) 2,584 (1,172)

1 3 1 BTP-300-1500 300 (1,136) 1,500,000 1,695 (6,416) 1,455 (5,508) 1/2 HP 7.4 AMPS 12 91 /2 (232) 44 /4 (114) 82 /2 (210) 2,774 (1,258)

1 1 BTP-400-600 400 (1,514) 600,000 902 (3,414) 582 (2,203) 1/4 HP 4.6 AMPS 8 91 /2 (232) 55 (140) 77 /2 (197) 3,207 (1,455)

1 1 BTP-400-800 400 (1,514) 800,000 1,096 (4,149) 776 (2,937) 1/3 HP 5.5 AMPS 10 91 /2 (232) 55 (140) 77 /2 (197) 3,212 (1,457)

1 1 BTP-400-1000 400 (1,514) 1,000,000 1,290 (4,883) 970 (3,672) 1/3 HP 5.5 AMPS 10 91 /2 (232) 55 (140) 77 /2 (197) 3,212 (1,457)

1 1 BTP-400-1250 400 (1,514) 1,250,000 1,532 (5,799) 1,212 (4,588) 1/3 HP 5.5 AMPS 12 91 /2 (232) 55 (140) 77 /2 (197) 3,212 (1,457)

1 1 BTP-400-1500 400 (1,514) 1,500,000 1,775 (6,719) 1,455 (5,508) 1/2 HP 7.4 AMPS 12 91 /2 (232) 55 (140) 92 /2 (235) 3,402 (1,543)

1 1 BTP-400-1750 400 (1,514) 1,750,000 2,017 (7,635) 1,697 (6,424) 1/2 HP 7.4 AMPS 14 91 /2 (232) 55 (140) 92 /2 (235) 3,528 (1,600)

1 1 BTP-400-2000 400 (1,514) 2,000,000 2,259 (8,551) 1,939 (7,340) 1/2 HP 7.4 AMPS 14 99 /2 (253) 55 (140) 92 /2 (235) 3,669 (1,664)

1 BTP-500-2250 500 (1,893) 2,250,000 2,582 (9,774) 2,182 (8,260) 3/4 HP 10.2 AMPS 16 110 (279) 55 (140) 92 /2 (235) 4,277 (1,940)

1 BTP-500-2500 500 (1,893) 2,500,000 2,824 (10,690) 2,424 (9,176) 3/4 HP 10.2 AMPS 16 110 (279) 55 (140) 92 /2 (235) 4,419 (2,004)

1 BTP-600-720 600 (2,271) 720,000 1,178 (4,459) 698 (2,642) 1/3 HP 5.5 AMPS 10 115 (292) 55 (140) 77 /2 (197) 3,667 (1,663)

1 BTP-600-1000 600 (2,271) 1,000,000 1,450 (5,489) 970 (3,672) 1/3 HP 5.5 AMPS 10 115 (292) 55 (140) 77 /2 (197) 3,667 (1,663)

1 BTP-600-1250 600 (2,271) 1,250,000 1,692 (6,405) 1,212 (4,588) 1/3 HP 5.5 AMPS 12 115 (292) 55 (140) 77 /2 (197) 3,667 (1,663)

1 BTP-600-1500 600 (2,271) 1,500,000 1,935 (7,325) 1,455 (5,508) 1/2 HP 7.4 AMPS 12 115 (292) 55 (140) 92 /2 (235) 3,837 (1,740)

1 BTP-600-1750 600 (2,271) 1,750,000 2,177 (8,241) 1,697 (6,424) 1/2 HP 7.4 AMPS 14 115 (292) 55 (140) 92 /2 (235) 3,837 (1,740)

1 BTP-600-2000 600 (2,271) 2,000,000 2,419 (9,157) 1,939 (7,340) 1/2 HP 7.4 AMPS 14 115 (292) 55 (140) 92 /2 (235) 3,837 (1,740)

1 BTP-600-2250 600 (2,271) 2,250,000 2,662 (10,077) 2,182 (8,260) 3/4 HP 10.2 AMPS 16 115 (292) 55 (140) 92 /2 (235) 4,477 (2,031)

1 BTP-600-2500 600 (2,271) 2,500,000 2,904 (10,993) 2,424 (9,176) 3/4 HP 10.2 AMPS 16 115 (292) 55 (140) 92 /2 (235) 4,619 (2,095) Field certification required on all BTP installations in Canada.

15 GAS WATER HEATERS Small Volume Power Burner Powered burner models provide BTP Gas Models thermal efficiencies of 80%.

These gas powered burner models provide an outstanding thermal efficiency of 80% or more and are suitable for small to medium-sized commercial applications.

Small-Volume BTP Quality Features n UL listed power burner n ASME construction n Factory-installed ASME-rated T&P valve properly sized for each model n Hand hole clean outs for easy maintenance n Fully automatic controls ensure safe, efficient operation n Barometric draft damper ensures correct air flow in the vent n Professional start-up provided n Mounted on rugged channel iron skids for easy transport during installation n Multiple anodes for extra protection against tank corrosion n Flame inspection port opening for visual inspection of flame characteristics during operation n Spark pilot ignition ­n Factory-installed burner for easy installation Codes and Standards n All models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 3-Year Limited Tank/1-Year Limited Parts Warranty n Factory start-up is required to validate warranty

LOW LEAD CONTENT Options n 3 vent options: atmospheric, sidewall and direct-vent (to be specified at time of order) HLW Shown here is the powered burner combustion chamber used in the BTP(V)-540A, BTP(V)-650A and BTP(V)-740A models. These models can vent through a sidewall up to 100 equivalent feet without an external blower. 1. Exclusive PermaGlas® Ultra Coat™ Glass-Lined Tank protects tank surfaces and all welds from the corrosive effects of hot water. 2. Patented Dome Combustion Chamber ensures optimum flue loading and efficient heat transfer by balancing pressure inside combustion chamber. 3. Pre-mix Combustion System provides super clean low-NOx flame. Helps eliminate hot spots and uneven heat transfer. 4. Sealed Combustion Chamber reduces heat loss.

FIRST RECOVERY APPROX. VENT CAPACITY INPUT HOUR 100°F (56°C) HEIGHT DIAMETER SHIPPING MODEL DIAMETER USG (L) BTU/h RATING TEMP. RISE IN (CM) IN (CM) WEIGHT (IN) GPH (LPH) GPH (LPH) LB (KG)

1 BTP(V)-540A 85 (322) 540,000 583 (2,207) 523 (1,980) 9 80 ¾ (205) 29 /2 (75) 950 (431)

1 BTP(V)-650A 85 (322) 650,000 690 (2,612) 630 (2,385) 9 80 ¾ (205) 29 /2 (75) 950 (431)

1 BTP(V)-740A 85 (322) 740,000 778 (2,945) 718 (2,718) 9 80 ¾ (205) 29 /2 (75) 950 (431)

(V) - Available for Sidewall Vent or Direct Vent 16 OIL-FIRED

COF models provide thermal WATER HEATERS Oil-Fired Small-Volume Models efficiencies up to 82%.

Our COF-199 and larger models have an optional two-stage pump for use with below-grade oil storage tanks. Features include two hand hole clean outs for easy servicing.

Small-Volume COF Quality Features n For small to medium-sized applications n UL listed oil burner n 180°F adjustable thermostat n Single-stage oil pump for simple, efficient operation n Solenoid oil valve (standard on COF-455, COF-700)­­ n 3/4˝ drain valve n 1/8 HP motor n Factory-installed ASME-rated T&P valve properly sized for each model n Two hand hole clean outs (COF-385 and larger, and ASME models) for easy maintenance n Barometric draft regulator provided for proper operation, ensures correct flow in the vent n Foam insulation n Intermittent ignition n Anodic protection for longer tank life n Flame observation port n Glass-lined tank with 160 psi maximum working pressure n Professional start-up provided 3-Year Limited Tank/1-Year Limited Parts Warranty n Factory start-up is required to validate warranty Options n Two-stage pump for use with underground LOW LEAD oil storage tanks HLW CONTENT n Oil solenoid safety valve n ASME construction available on models COF-315 and larger

MAXIMUM RECOVERY APPROX. CAPACITY INPUT* CERTIFIED 100°F (56°C) HEIGHT DIAMETER DEPTH SHIPPING WEIGHT MODEL USG (L) BTU/h ALTITUDE TEMP. RISE IN (CM) IN (CM) IN (CM) LB (KG) FT (M) GPH (LPH) STD ASME

1 3 COF-199 86 (326) 199,000 2,000 (610) 191 (723) 74 /2 (189) 27 /4 (70) 36 ¾ (93) 553 (251) -

1 3 COF-245 86 (326) 245,000 2,000 (610) 235 (890) 74 /2 (189) 27 /4 (70) 36 ¾ (93) 554 (251) -

1 3 COF-315(A) 84 (318) 315,000 2,000 (610) 302 (1,143) 74 /2 (189) 27 /4 (70) 36 ¾ (93) 554 (251) 657 (298)

3 3 COF-385(A) 75 (284) 385,000 2,000 (610) 369 (1,397) 73 /4 (187) 27 /4 (70) 36 ¾ (93) 624 (283) 742 (337)

3 3 COF-455(A) 75 (284) 455,000 2,000 (610) 436 (1,650) 73 /4 (187) 27 /4 (70) 36 ¾ (93) 700 (318) 747 (339)

3 3 COF-700(A) 69 (261) 700,000 2,000 (610) 671 (2,540) 73 /4 (187) 27 /4 (70) 36 ¾ (93) 739 (335) 822 (373) (A) -Available in ASME models *Based on No. 2 fuel oil

17 OIL-FIRED

Heavy-Duty Oil-Fired WATER HEATERS Large Volume High Output Oil COF/COBT Models and Dual Fuel Water Heaters.

COF models offer oil-fuel burners for use with No. 1 or 2 oil. COBT models feature combination gas/oil powered burners for the versatility of operating with natural gas/propane and No. 1 or 2 oil. COF/COBT models include some of the largest and most powerful A. O. Smith tank-type water heating systems available – with storage/input options up to 600 gallons/2,500,000 BTU/h and recoveries as high as 2,424 gallons/hour at 100°F rise. All models feature fully automatic controls with safety shut off, two thermostats (upper and lower) for accurate temperature control, and ASME tank construction.

COF (Oil-Fired Models) n Use either No. 1 or 2 fuel oil n 3,450 rpm motor n Multi-annular fuel containment combustor head n Oil ignition transformer n Integral 2-stage fuel unit and oil safety valve COBT (Combination Gas/Oil-Fired Models) n Use either natural gas or propane and No. 1 or 2 fuel oil n 3,450 rpm motor n Multi-annular fuel containment combustor head n Gas/electric pilot and gas ignition transformer n Pilot and main pressure regulators n Air safety switch n Manual fuel selector switch n Integral 2-stage fuel unit Fully Automatic Controls with Safety Shut Off n High temperature limit control (manual reset) n ASME-rated T&P valve HLW n Hinged door control (COBT models) compartment for easy access n Upper and lower thermostats for accurate temperature control Glass-Lined Tank n Exclusive corrosion protection with glass-lining on all interior surfaces n Equipped with multiple anode rods for additional corrosion protection Heavy-Duty Jacket n Heavy gauge steel jacket with baked powder-coated finish for durability n Two 3˝ hand hole inspection openings Maximum Hydrostatic Working Pressure n 160 psi for all models Professional Start-Up Service n Assures most efficient combustion and safe 18 initial installation OIL-FIRED WATER HEATERS

­­­Two Layers of High Temperature Ceramic COF/COBT Options Fiber Insulation in Combustion Chamber n Factory mutual approved control arrangement n High or low water pressure switch Flame Inspection Port Opening n 180°F water service thermostats Mounted on Rugged Channel Iron Skids n ASME-rated T&P valve n Modular graphic burner systems management ASME Stamping on heaters with 270,000 BTU/h input and greater Low Water Cut Off Codes and Standards n All models meet the thermal efficiency and 3-Year Limited Tank/1-Year Limited Parts standby loss requirements of NRCan and current Warranty edition of ASHRAE/IESNA 90.1 n Factory start-up is required to validate warranty

COBT COF APPROX. OIL FIRST HOUR RECOVERY VENT CAPACITY INPUT MOTOR MOTOR HEIGHT DIAMETER DEPTH SHIPPING MODEL FIRING RATE RATING 100°F (56°C) TEMP. RISE DIAMETER USG (L) BTU/h HP 1 Ø HP 1 Ø IN (CM) IN (CM) IN (CM) WEIGHT GPH (LPH) GPH (LPH) GPH (LPH) (IN) 120V 120V LB (KG)

1 COF-150-140 163 (617) 140,000 1 (3.8) 241 (912) 136 (515) 5 82 ¼ (209) 36 /2 (93) 47 (119) 1,292 (586)

1 COF-150-199 163 (617) 199,000 1.4 (5.3) 298 (1,128) 193 (731) 1/7 HP 6 82 ¼ (209) 36 /2 (93) 47 (119) 1,292 (586) 1 COF-150-255 163 (617) 255,000 1.8 (6.8) 352 (1,332) 247 (935) 4.4 Amp 6 82 ¼ (209) 36 /2 (93) 47 (119) 1,292 (586)

1 COF-150-270 163 (617) 270,000 1.9 (7.2) 367 (1,389) 262 (992) 6 82 ¼ (209) 36 /2 (93) 57 ½ (146) 1,397 (634)

1 COBT-150-350 150 (568) 350,000 2.2 (8.3) 444 (1,681) 339 (1,283) 7 82 ¼ (209) 36 /2 (93) 57 ½ (146) 1,397 (634)

1 COF/COBT-150-400 151 (572) 400,000 2.8 (10.6) 452 (1,711) 387 (1,465) 7 82 ¼ (209) 36 /2 (93) 57 ½ (146) 1,397 (634)

1/3 HP 1 COF/COBT-150-540 151 (572) 540,000 3.8 (14.4) 629 (2,381) 524 (1,984) 8 82 ¼ (209) 36 /2 (93) 57 ½ (146) 1,505 (683) 5.5 Amp 1/4 HP 1 COF/COBT-150-720 145 (549) 720,000 5.1 (19.3) 803 (3040) 698 (2,642) 4.6 Amp 10 82 ¼ (209) 36 /2 (93) 57 ½ (146) 1,510 (685) COF/COBT-200-300* 221 (837) 300,000 2.1 (7.9) 446 (1,688) 291 (1,102) 6 84 ½ (215) 44 ¾ (114) 66 ½ (169) 2,098 (952) COF/COBT-200-600 221 (837) 600,000 4.2 (15.9) 737 (2,790) 582 (2,203) 8 84 ½ (215) 44 ¾ (114) 66 ½ (169) 2,098 (952) COF/COBT-200-800 221 (837) 800,000 5.7 (21.6) 931 (3,524) 776 (2,937) 10 84 ½ (215) 44 ¾ (114) 66 ½ (169) 2,103 (954) 1/3 HP COF/COBT-200-1000 201 (761) 1,000,000 7.1 (26.9) 1,111 (4,206) 970 (3,672) 10 84 ½ (215) 44 ¾ (114) 66 ½ (169) 2,103 (954) 5.5 Amp COF/COBT-200-1250 201 (761) 1,250,000 8.9 (33.7) 1,353 (5,122) 1,212 (4,588) 12 84 ¾ (215) 44 ¾ (114) 66 ½ (169) 2,467 (1,119) COF/COBT-200-1500 201 (761) 1,500,000 10.7 (40.5) 1,560 (5,905) 1,455 (5,508) 3/4 HP 10.2 Amp 12 84 ¾ (215) 44 ¾ (114) 81 ½ (207) 2,675 (1,213) COF/COBT-300-300* 300 (1,136) 300,000 2.1 (7.9) 501 (1,896) 291 (1,102) 1/4 HP 6 92 (234) 44 ¾ (114) 66 ½ (169) 2,150 (975) COF/COBT-300-600 300 (1,136) 600,000 4.2 (15.9) 792 (2,998) 582 (2,203) 4.6 Amp 8 92 (234) 44 ¾ (114) 66 ½ (169) 2,150 (975) 1/3 HP COF/COBT-300-800 300 (1,136) 800,000 5.7 (21.6) 986 (3,732) 776 (2,937) 10 92 (234) 44 ¾ (114) 66 ½ (169) 2,308 (1,047) 5.5 Amp 1/3 HP COF/COBT-300-1000 300 (1,136) 1,000,000 7.1 (26.9) 1,180 (4,467) 970 (3,672) 10 92 (234) 44 ¾ (114) 66 ½ (169) 2,308 (1,047) 5.5 Amp COF/COBT-300-1250 300 (1,136) 1,250,000 8.9 (33.7) 1,422 (5,383) 1,212 (4,588) 12 92 (234) 44 ¾ (114) 66 ½ (169) 2,584 (1,172) COF/COBT-300-1500 300 (1,136) 1,500,000 10.7 (40.5) 1,665 (6,303) 1,455 (5,508) 3/4 HP 10.2 Amp 12 92 (234) 44 ¾ (114) 81 ½ (207) 2,774 (1,258) 1/4 HP COF/COBT-400-600 411 (1,556) 600,000 4.2 (15.9) 870 (3,293) 582 (2,203) 8 89 (226) 55 (140) 76 ½ (194) 3,207 (1,455) 4.6 Amp COF/COBT-400-800 411 (1,556) 800,000 5.7 (21.6) 1,064 (4,028) 776 (2,937) 1/3 HP 10 89 (226) 55 (140) 76 ½ (194) 3,212 (1,457) 5.5 Amp 1/3 HP COF/COBT-400-1000 411 (1,556) 1,000,000 7.1 (26.9) 1,268 (4,800) 970 (3,672) 10 89 (226) 55 (140) 76 ½ (194) 3,212 (1,457) 5.5 Amp COF/COBT-400-1250 411 (1,556) 1,250,000 8.9 (33.7) 1,500 (5,678) 1,212 (4,588) 12 89 (226) 55 (140) 76 ½ (194) 3,212 (1,457) COF/COBT-400-1500 397 (1,503) 1,500,000 10.7 (40.5) 1,733 (6,560) 1,455 (5,508) 12 89 (226) 55 (140) 91 ½ (232) 3,402 (1,543) 3/4 HP COF/COBT-400-1750 397 (1,503) 1,750,000 12.5 (47.3) 1,975 (7,476) 1,697 (6,424) 14 89 (226) 55 (140) 91 ½ (232) 3,528 (1,600) 10.2 Amp COF/COBT-400-2000 397 (1,503) 2,000,000 14.2 (53.8) 2,217 (8,392) 1,939 (7,340) 14 96 ¼ (244) 55 (140) 91 ½ (232) 3,669 (1,664) COF/COBT-500-2250 495 (1,874) 2,250,000 16.0 (60.6) 2,445 (9,255) 2,182 (8,260) 1 HP 16 108 (274) 55 (140) 91 ½ (232) 4,277 (1,940) COF/COBT-500-2500 495 (1,874) 2,500,000 17.8 (67.4) 2,687 (10,171) 2,424 (9,176) 16 Amp 16 108 (274) 55 (140) 91 ½ (232) 4,419 (2,004) COF/COBT-600-720 594 (2,249) 720,000 5.1 (19.3) 1,114 (4,217) 698 (2,642) 1/4 HP 10 114 (290) 55 (140) 76 ½ (194) 3,667 (1,663) COF/COBT-600-1000 594 (2,249) 1,000,000 7.1 (26.9) 1,386 (5,247) 970 (3,672) 1/3 HP 4.6 Amp 10 114 (290) 55 (140) 76 ½ (194) 3,667 (1,663) 5.5 Amp 1/3 HP COF/COBT-600-1250 594 (2,249) 1,250,000 8.9 (33.7) 1,627 (6,159) 1,212 (4,588) 12 114 (290) 55 (140) 76 ½ (194) 3,667 (1,663) 5.5 Amp COF/COBT-600-1500 594 (2,249) 1,500,000 10.7 (40.5) 1,871 (7,083) 1,455 (5,508) 12 114 (290) 55 (140) 91 ½ (232) 3,837 (1,740) 3/4 HP COF/COBT-600-1750 594 (2,249) 1,750,000 12.5 (47.3) 2,116 (8,010) 1,697 (6,424) 14 114 (290) 55 (140) 91 ½ (232) 3,837 (1,740) 10.2 Amp COF/COBT-600-2000 594 (2,249) 2,000,000 14.2 (53.8) 2,355 (8,915) 1,939 (7,340) 14 114 (290) 55 (140) 91 ½ (232) 3,837 (1,740) COF/COBT-600-2250 575 (2,177) 2,250,000 16.0 (60.6) 2,585 (9,785) 2,182 (8,260) 1 HP 16 114 (290) 55 (140) 91 ½ (232) 4,477 (2,031) COF/COBT-600-2500 575 (2,177) 2,500,000 17.8 (67.4) 2,827 (10,701) 2,424 (9,176) 16 Amp 16 114 (290) 55 (140) 91 ½ (232) 4,619 (2,095) *COBT models are 350,000 BTU Field certification required on all COF/COBT installations in Canada

19 ELECTRIC

WATER HEATERS DEN/DEL Electric Dura-Power™ Models

The Dura-Power DEN (standard upright) and DEL (lowboy) series are available with tank capacities from 6 through 119 gallons. They can be installed for non-simultaneous and single-element operation (maximum input up to 6 kW ) or for simultaneous dual-element operation (maximum input up to 12 kW). They are designed for use as recovery heaters for light-duty hot water supply service.

Zinc-Plated Copper Sheath Factory-Wired Controls Heating Elements Standard n Temperature control adjustable from 110°F to 170°F on single- element n Medium-watt density design or 120°F to 180°F on dual element disperses element temperature models over larger surface contact area to n Manual reset high temperature minimize scale build-up, maximize cut off per element (dual element efficiency and prolong element life models) n Factory-wired for non-simultaneous n Element options from 1.5 kW to 6 operation; easily converted to kW (non-simultaneous simultaneous operation or simultaneous operation), (three-phase models only) recoveries from 6 GPH to 49 GPH at 100°F rise Glass-Lined Tank n Provides long-lasting protection Standard Voltages for Easy against corrosion n Equipped with anode rod for Installation additional corrosion protection n 120V, 277V single-phase, and 208V, 240V and 480V Maximum Hydrostatic Working unbalanced three-phase delta Pressure n Easily converted to single-phase at n 150 psi for all models terminal block (except for 208V with 6000W elements) Codes and Standards n n Single-element heater, single-phase All models meet the thermal efficiency and standby loss only (see chart for dual-element requirements of NRCan and current options) edition of ASHRAE/IESNA 90.1

LOW LEAD 3-Year Limited Tank/1-Year CONTENT Factory-Installed Terminal Block Limited Parts Warranty n Supplied on 208V, 240V and 480V For complete information on available models configurations, consult spec sheet.

ELEMENT AVAILABILITY APPROX. CAPACITY MAXIMUM HEIGHT DIAMETER SHIPPING MODEL INPUT (W) 120V 208V 240V 277V 480V USG (L) KILOWATTS IN (CM) IN (CM) WEIGHT LB (KG) 1500 Yes Yes Yes Yes - SINGLE ELEMENT POINT-OF-USE MODELS

2000 Yes Yes Yes Yes - 1 1 DEL-6S 6 (23) 3 15 /2 (39) 14 /4 (36) 35 (16)

2500 Yes Yes Yes Yes Yes 1 DEL-10S 10 (37) 6 18 /4 (46) 18 (46) 54 (24) 3000 Yes* Yes Yes Yes Yes DEL-15S 13 (49) 6 26 (66) 18 (46) 58 (26)

3500 - Yes Yes - - 1 3 DEL-20S 19 (74) 6 22 /4 (57) 21 /4 (55) 73 (33) 4000 - Yes Yes Yes Yes DUAL ELEMENT MODELS*

4500 - Yes Yes Yes Yes 7 3 DEL-30D 29 (111) 12 30 /8 (78) 21 /4 (55) 100 (45) t 5000 - Yes Yes - Yes 1 DEL-40D 38 (145) 12 32 /4 (82) 24 (61) 125 (57)

5500 - - Yes - - 1 1 DEL-50D 46 (175) 12 32 /4 (82) 26 /2 (67) 166 (75)

6000 - (Yes) (Yes) Yes Yes 1 1 DEN-30 28 (107) 12 34 /2 (88) 20 /2 (52) 98 (44) 6 gallon model not available above 3kW 1 1 6/10/15/20 gallon models all A6 circuit (2 wire) only DEN-40 37 (143) 12 45 /8 (115) 20 /2 (52) 113 (51) * On dual element models, only available for non-simultaneous operation 7 1 DEN-52 46 (175) 12 54 /8 (139) 20 /2 (52) 131 (59) † On dual element models, only available for 3 phase simultaneous operation 3 3 () Only available on single element models DEN-66 62 (237) 12 60 /4 (154) 21 /4 (55) 176 (80)

3 DEN-80 75 (284) 12 59 /8 (151) 24 (61) 211 (96)

7 3 20 DEN-120 113 (428) 12 62 /16 (159) 29 /8 (75) 326 (148) *Pre-wired for unbalanced three-phase only, non-simultaneous operation of elements standard. Can be re-wired for single phase operation. ELECTRIC

DRE/DVE Electric WATER HEATERS Gold and Gold Xi™ Series

Gold and Gold Xi DRE/DVE series available with 50, 80, and 119 gallon storage tanks, with input choices ranging from 6 kW to 54 kW. They can be used as recovery heaters for hot water supply service or as boosters for supplying sanitizing rinse water for dish washing.

Goldenrod® 24k gold-plated n Brass drain valve n Banks of heating elements (3 Elements Standard n CSA Certified and ASME rated elements per bank) are energized temperature and pressure relief according to adjustable (1˚ to 20˚F) n Superior scaling resistance, valve differential set points for each resulting in long term efficiency bank. Helps reduce current surge and damage protection DRE Gold Model Controls and provides accurate water n Element sizes from 2 kW to n DRE Gold models have surface temperature control 6 kW in 3, 6 or 9 element mounted thermostats with n Linear sequencing - first bank configurations provide input temperature control adjustable on is last bank off options from 6 kW to 54 kW, 120° to 181°F n Helps reduce current surge/spikes recoveries from 25 GPH to 221 n Manual reset high temperature and avoid peak demand charges GPH at 100°F rise cut off n Helps reduce operating costs during low load conditions Internal Fusing for System DVE Gold Xi Model Features n Manual reset high temperature Protection cut off n Safeguards elements and Advanced Electronic Controls contactors from short circuits, n iCOMM ™ compatible and can be Compliance overloading and line surges monitored from remote locations. n All models meet the thermal Call 1.888.WATER02 for more efficiency and standby loss Standard 208, 240 and 480V information requirements of NRCan and current Options for Easy Installation n Connect to an existing building edition of ASHRAE/IESNA 90.1 management system via BACnet n Single-phase and three-phase or MODBUS with optional ICC delta gateway 3-Year Limited Tank/1-Year n Field-convertible voltages three- n Plain English text and animated Limited Parts Warranty phase to single-phase (and vice icons versa) except for 208V/54 kW n Displays detailed operational n 277V single-phase also available and diagnostic information n Fault or alert messages appear Factory-Installed Terminal if an operational issue occurs Block n Last 9 fault and alert messages n Provide electrical service to heater saved with time stamp ­ and connect to block Economy Mode Operation Heavy-Duty Magnetic n Control system automatically Contactors (DVE Models Only) lowers the operating set point by a programmed value during n UL-rated 100,000 cycles user-defined time periods n Helps reduce operating costs Other Standard DRE/DVE during unoccupied or low Features demand periods n Two anode rods for maximum Precise Temperature Regulation corrosion protection n Immersion thermostat allows n Simplified circuitry, colour-coded for more accurate temperature for ease of service adjustment from 90° to 190°F DVE Model DRE Model n Bonderized undercoated baked enamel finished cabinets

LOW LEAD APPROX. CONTENT (DVE Models Only) CAPACITY MAXIMUM HEIGHT DIAMETER SHIPPING WEIGHT MODEL USG (L) KILOWATTS IN (CM) IN (CM) LB (KG) STD ASME

3 3 DVE/DRE-52 50 (189) 54 55 /4 (142) 21 /4 (55) 265 (120) 315 (143) HLW 1 1 (Optional) DVE/DRE-80 80 (303) 54 60 /4 (153) 25 /2 (65) 280 (127) 330 (150)

1 1 DVE/DRE-120 119 (450) 54 62 /4 (158) 29 /2 (75) 390 (177) 440 (200) 21 ELECTRIC

WATER HEATERS Heavy-Duty Custom Xi™ Series Electric DSE Models

The heavy-duty Custom Xi DSE series is Incoloy Sheath Heating Elements Progressive Sequencing available with storage capacities from 5 Standard n First heating element on is first heating element off to 119 gallons. All tanks feature ASME n Industrial-grade incoloy sheathed heating elements are designed for rugged long- n First heating element energized is rotated tank construction. With input choices as lasting commercial service, and can with each successive heating cycle on high as 90 kW on 50 through 119 gallon withstand sheath temperatures up to models with multiple heating elements models, the DSE Custom Xi series can be 1500°F n Evens out wear between heating elements n Each heating element has three separate used for maximum-demand hot water n Helps reduce current surge/spikes and heating loops, which provides more avoid peak demand charges supply service or as boosters for supplying heating surface, lower watt density and maximum recovery efficiency sanitizing rinse water for dish washing. Economy Mode Operation n Pre-wired leads provide excellent protection against oxidation and scaling n Control system automatically lowers the operating set point by a programmed n Input options from 3 kW to value during user-defined time periods 90 kW, recoveries from 12 GPH to 369 GPH at 100°F rise n Helps reduce operating costs during unoccupied or low demand periods Standard Voltages for Easy Installation n 208, 240 and 480V single-phase and three- Precise Temperature Regulation phase n Advanced electronic control provides n Single-phase 208V and 240V are field- precise ±1°F temperature control that convertible to three-phase is ideal for industrial and food service applications where exact temperatures of n All 208V and 240V at 24 kW and below are hot water are needed supplied as phase-convertible units (single- to three-phase and vice versa) n Operating set point is adjustable from 90° to 190°F n 277V single-phase also available (Contact A. O. Smith for 120V circuit availability) n Manual reset high temperature cut off n 380, 415, 575 and 600 international Heavy-Duty Magnetic Contactors voltages also available (check with A. O. Smith) Power Circuit Fusing for System Factory-Installed Terminal Block Protection n To accept copper or aluminum leads (on ® units with more than one contactor) PermaGlas Ultra Coat™ Glass Lining with ASME Tank Construction Advanced Electronic Controls n iCOMM™ compatible and can be CSA Certified and ASME Rated monitored from remote locations. Call T&P Relief Valve 1.888.WATER02 for more information n Plain English text and animated icons Compliance n Connect to an existing building n All models meet the thermal efficiency management system via BACnet or and standby loss requirements of NRCan

LOW LEAD MODBUS with optional ICC gateway and current edition of ASHRAE/IESNA 90.1 HLW CONTENT n Displays detailed operational and Brass Drain Valve Optional Goldenrod® diagnostic information 24-karat gold-plated n Fault or alert messages appear if an elements resist lime operational issue occurs 3-Year Limited Tank/1-Year Limited scale adhesion and Parts Warranty sheath temperatures n Last 9 fault and alert messages saved with up to 1500ºF. time stamp

MAXIMUM APPROX. CAPACITY HEIGHT DIAMETER SHIPPING MODEL USG (L) INPUT IMMERSION IN (CM) IN (CM) WEIGHT (kW) HEATERS LB (KG)

1 DSE-5 5 (19) 3 1 20 ¼ (51) 16 /4 (41) 82 (37)

3 DSE-10 10 (38) 6 1 26 ¼ (67) 18 /4 (48) 116 (53)

1 1 DSE-20 20 (76) 18 2 27 /4 (69) 20 /2 (52) 145 (66)

3 1 DSE-30 30 (114) 24 2 35 /4 (91) 20 /2 (52) 150 (68)

3 1 DSE-40 40 (151) 36 2 45 /4 (116) 20 /2 (52) 190 (86)

3 1 DSE-50 50 (189) 90 5 54 /4 (139) 20 /2 (52) 221 (100)

1 DSE-65 65 (246) 90 5 54 (137) 26 /2 (67) 280 (127) DSE-80 80 (303) 90 5 52 ¼ (132) 28 (71) 285 (129) DSE-100 100 (379) 90 5 60 ½ (154) 28 (71) 354 (161) DSE-120 120 (450) 90 5 65 ½ (166) 30 (76) 420 (191) 22 ELECTRIC

Heavy-Duty CMC/SU Booster WATER HEATERS Electric Dura-Power™ Models

The Dura-Power commercial electric water heaters are designed to boost the water temperatures for applications such as commercial dishwashers, which require very high temperature sanitizing rinse...typically 180°F. Both 5-gallon countermount CMC models and 20-gallon SU models are available with inputs up to 54 kW. All models are also available with an optional stainless steel tank, for use with deionized water.

Incoloy-Sheath Heating Immersion Thermostat for Elements Standard Efficient Control n Industrial-grade incoloy n Close differential, immersion- sheathed heating elements type thermostat for superbly are designed for rugged accurate temperature control long-lasting commercial n service and can withstand Adjustable from 140°F to 185°F sheath temperatures up to n Manual reset high temperature 1500°F cut off n Each heating element has three separate heating loops, Power Circuit Fusing for which provides more heating System Protection surface, lower watt density and maximum recovery efficiency n Safeguards elements and n Pre-wired leads provide contactors from short circuits, excellent protection against overloading and line surges oxidation and scaling n Input options from 6 kW to Heavy-Duty Magnetic 54 kW and recoveries from Contactors 25 GPH to 221 GPH at 100°F rise n UL-rated 100,000 cycles n Deionized models equipped with stainless steel standard elements Factory-Wired 120V Circuit Controls A. O. Smith Goldenrod® n 120V control circuit powered Elements Optional by fused transformer n n Patent pending 24K gold-plated Eliminates need for 120V sheath plus medium watt service connection density ensures even longer element life Compliance HLW n Higher resistance to scale n All models meet the thermal build up compared to incoloy efficiency and standby loss Optional Goldenrod® elements requirements of NRCan 24-karat gold-plated and current edition of elements resist lime n Three-year warranty against scale adhesion and ASHRAE/IESNA 90.1 sheath temperatures failure due to lime scale build-up up to 1500ºF. n Not available on deionized 3-Year Limited Tank/1-Year models Limited Parts Warranty

Standard Voltages for APPROX. NO. OF INLET & CAPACITY HEIGHT WIDTH DEPTH SHIPPING Easy Installation MODEL IMMERSION OUTLET USG (L) IN (CM) IN (CM) IN (CM) WEIGHT n HEATERS (IN) Single-phase and three-phase LB (KG)

n 3 3 Single-phase 208V and 240V are CMC-6 through 18 5 (19) 1 /4 13 /4 (35) 13 (33) 23 ½ (60) 80 (36)

3 field-convertible to three-phase CMC-20 through 54 5 (19) 2* /4 12 (31) 18 (46) 23 ½ (60) 96 (44)

3 1 n CMC models only, 208V and SU-6 through 18 20 (76) 1 /4 25 (64) 22 /4 (57) 23 (58) 200 (91) 3 1 240V at 24 kW and below are SU-20 through 54 20 (76) 2* /4 25 (64) 22 /4 (57) 23 (58) 200 (91) supplied as phase-convertible *CMC-54 and SU-54 have three immersion heaters units (single- to three-phase and vice versa) n 277V single-phase also available (contact A. O. Smith for 120V circuit availability) 23 ELECTRIC

WATER HEATERS Heavy-Duty Premium Electric ™ DVE/DHE Dura-Power Xi Models

Dura-Power commercial electric water heaters are built to the same high quality standards as our gas models. These are the largest commercial electrics we manufacture. Ideal for use as recovery heaters for all types of large commercial and industrial applications or for large process potable hot water requirements. They can be customized to meet any special application with the large selection of available options.

Advanced Electronic Control Incoloy Immersion Heaters n A. O. Smith’s proprietary electronic n Heavy-duty medium watt density water heater control provides elements (three immersion heater) precise ±1°F temperature control, have incoloy sheathing providing that is ideal for industrial and food excellent protection against service applications where exact oxidation and scaling with input temperatures of hot water are ranges from 15 kW to 3000 kW needed. Power Circuit Fusing for System Protection ·  Animated icons display detailed operational and diagnostic Compliance information, and plain text fault n All models meet the thermal or alert messages appear if an efficiency and standby loss operational issue occurs requirements of NRCan and current edition of ASHRAE/IESNA 90.1 · Low water cut off is factory standard and uses a remote Magnetic Contactor(s) electronic immersion type probe to n Heavy duty UL rated for 100,000 prevent energizing of the elements cycles in the event of low water condition and eliminates accidental dry firing Other Standard Features · Progressive modulating sizes the n Colour-coded circuitry for easier input of available elements to servicing n Anode rods for maximum corrosion HLW LOW LEAD match current load conditions and CONTENT rotates and lead lags element loads protection to provide long life and equal wear n Standard voltages include 208, 240, Optional Goldenrod® 480, 600 volt single or three-phase 24-karat gold-plated · Economy mode operation elements resist lime n For other voltages consult scale adhesion and automatically lowers the operating A. O. Smith sheath temperatures set point by a programmed value n Factory-installed terminal block(s) up to 1500ºF. during user defined time periods n Cabinet has baked enamel finish using a seven-day clock that may be programmed for night set n Pre-wired element terminal leads back and/or weekend shutdown n Temperature and pressure relief to reduce operating cost and save valve money n Tanks have a channel skid base n A 4" x 6" hand hole is furnished on · iCOMM™ compatible and can be 500, 600 and 700 gallon models and a monitored from remote locations. 11" x 15" manhole on 800 gallon and Call 1.888.WATER02 for more larger sizes information. Optional Dual-Energy Source · Building management system compatible via BACnet or MODBUS Capability with optional ICC gateway n Provides emergency back up energy source or winter/summer boiler operation ® PermaGlas Ultra Coat™ n Can be specified with optional water Glass Lining to water or steam to water heat exchangers n Exclusive process provides superior protection against corrosion in n Both single and double wall heat varying water conditions exchangers are available n Complete control packages can be factory installed for hook up and ASME Code Construction run capability n All models are constructed to the requirements of ASME and are 3-Year Limited Tank/1-Year available in 100, 125, 150 and 160 Limited Parts Warranty psi working pressures (125 psi working pressure is standard) 24 ELECTRIC WATER HEATERS

Options n 3-1/2” DIAL-TYPE TEMPERATURE GAUGE – Factory-installed. n TANK LININGS n 11” x 15” MANHOLE – Available as option on tanks 700 gallons CEMENT – A special formulation of cement providing excellent down to 30" tank diameter. corrosion protection. Available on 200-gallon and larger tanks.

EPOXY – A solventless two component epoxy lining applied to a Control Options minimum ten-mil (.010”) dry thickness. Available on 200-gallon n COPPER TUBE TANK HEATER – Double wall copper tube tank and larger tanks. heaters are designed for heating potable water with both potable or non-potable liquids or steam, and are specifically engineered for n GOLDENROD ® ELEMENTS – Available with optional Goldenrod installation in models DVE and DHE for dual-energy applications. elements - All DVE/DHE models are available with the Goldenrod Tank heaters have a positive fail-safe means of leak detection in 24K gold plated elements (patent pending). Goldenrod elements the event of either tube failure to prevent mixture of heating provide long-life and five times the scaling resistance of standard medium and potable water. Single wall heat exchangers are also incoloy elements. Goldenrod elements carry a three-year warranty available. against failure due to scale buildup. n TERMINAL BLOCKS – Allows for remote connection to building n STAINLESS STEEL VESSELS – Are available for deionized water. Built demand limiter or other functions. with stainless steel under rules of Section IV of the ASME Boiler n AUTOMATIC RESET HIGH LIMIT – A control that in the event of and Pressure Vessel Code for operation on deionized water having high temperature, interrupts power, -energizing elements, a minimum specific resistivity of 10 megohm/cm. automatic reset. (Standard with modulating step control). n 150 OR 160 PSI WORKING PRESSURE – Must be specified at time of n INDICATING LIGHTS – Denotes heating stage(s) in operation. Up to order. one light per contactor is available. Other Optional Features n OVERRIDE SWITCHES – A simple means of load control allows all or n TEMPERATURE AND PRESSURE RELIEF VALVES – For working part of unit input to be controlled manually. Up to one switch per pressures other than standard consult factory. contactor is available. n HORIZONTAL OR VERTICAL – See specifications, most gallon n SAFETY DOOR INTERLOCK – Prevents opening of control panel capacities may be obtained in vertical or horizontal construction. door when heater power supply is on. NOTE: Once door is opened n CIRCULATING PUMP PACKAGE – Circulating pump and piping heater may be energized if necessary for service diagnosis. sized to turn over entire storage capacity of tank once each hour. n SHUNT TRIP CIRCUIT BREAKER – A safety device (circuit breaker) Recommended to optimize available water at temperature in which disconnects power to heater in the event of over-current, horizontal tanks particularly where low draw conditions high temperature or low water level, breaker must be are anticipated. manually reset. n OPTIONAL INTERNATIONAL VOLTAGES – 380 and 415 volts three-phase. n CIRCUIT BREAKER – A safety device which disconnects power to the n 3-1/2” DIAL-TYPE PRESSURE GAUGE – Factory-installed. heater in the event of overcurrent.

HORIZONTAL ELECTRIC STORAGE HEATERS VERTICAL ELECTRIC STORAGE HEATERS

MAX MAX CAPACITY HEIGHT WIDTH DEPTH CAPACITY HEIGHT WIDTH DEPTH MODEL* INPUT MODEL* INPUT USG (L) IN (CM) IN (CM) IN (CM) USG (L) IN (CM) IN (CM) IN (CM) (kW) (kW)

1 DHE-200 200 (757) 180 38 /2 (98) 77 (196) 36 (91) DVE-140 140 (530) 150 83 ½ (212) 30 (76) 37 (94)

1 1 DHE-250 250 (946) 240 38 /2 (98) 91 (231) 36 (91) DVE-150 150 (568) 150 83 /2 (212) 30 (76) 37 (94)

1 1 DHE-300 300 (1,136) 300 44 /2 (113) 81 (206) 42 (107) DVE-150L 150 (568) 150 59 /2 (151) 36 (91) 43 (109)

1 1 DHE-350 350 (1,325) 330 44 /2 (113) 93 (236) 42 (107) DVE-200 200 (757) 180 79 /2 (202) 36 (91) 43 (109)

1 DHE-400 400 (1,514) 390 44 /2 (113) 100 (254) 42 (107) DVE-250 250 (946) 240 93 (236) 36 (91) 43 (109) 1 DHE-500 500 (1,893) 480 51 (130) 94 (239) 48 (122) DVE-300 300 (1,136) 300 83 /2 (212) 42 (107) 49 (124) 1 DHE-600 600 (2,271) 600 51 (130) 109 (277) 48 (122) DVE-350 350 (1,325) 330 95 /2 (243) 42 (107) 49 (124) 1 DHE-700 700 (2,650) 690 51 (130) 121 (307) 48 (122) DVE-400 400 (1,514) 390 102 /2 (206) 42 (107) 49 (124) DHE-800 800 (3,028) 780 57 (145) 111 (282) 54 (137) DVE-500 500 (1,893) 480 97 (246) 48 (122) 55 (140) DHE-1000 1,000 (3,785) 990 61 (155) 111 (282) 60 (152) DVE-600 600 (2,271) 600 112 (284) 48 (122) 55 (140) DHE-1250 1,250 (4,732) 1,200 61 (155) 138 (351) 60 (152) DVE-700 700 (2,650) 690 124 (315) 48 (122) 55 (140) DHE-1500 1,500 (5,678) 1,500 61 (155) 150 (381) 60 (152) DVE-800 800 (3,028) 780 116 (295) 56 (142) 61 (155) DHE-2000 2,000 (7,571) 1,980 70 (178) 177 (450) 66 (168) DVE-1000 1,000 (3,785) 990 116 (295) 60 (152) 67 (170) DHE-3000 3,000 (11,356) 3,000 76 (193) 211 (536) 72 (183) DVE-1250 1,250 (4,732) 1,200 143 (363) 60 (152) 67 (170) DHE-5000 5,000 (18,927) 3,000 82 (208) 296 (752) 78 (198) DVE-1500 1,500 (5,678) 1,500 155 (394) 60 (152) 67 (170) DHE-7500 7,500 (28,391) 3,000 94 (239) 317 (805) 90 (229) DVE-2000 2,000 (7,571) 1,980 183 (465) 66 (168) 73 (185) DHE-10,000 10,000 (37,854) 3,000 106 (269) 345 (876) 102 (259) DVE-3000 3,000 (11,356) 3,000 217 (551) 72 (183) 79 (201)

*Complete model number includes the desired kW at the end. DVE-5000 5,000 (18,927) 3,000 309 (785) 78 (198) 85 (216) Minimum installation clearances required: 30˝ (76 cm) from front, 12˝ (30 cm) DVE-7500 7,500 (28,391) 3,000 330 (838) 90 (229) 97 (246) from top and 24˝ (61 cm) from right side. DVE-10,000 10,000 (37,854) 3,000 358 (909) 102 (259) 109 (277)

*Complete model number includes the desired kW at the end. Minimum installation clearances required: 30˝ (76 cm) from front, 12˝ (30 cm) from top and 24˝ (61 cm) from right side.

Field certification required on all DVE/DHE installations in Canada. 25 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS

XWH Model Circulating Water Heaters

The ENERGY STAR® qualified A. O. Smith high efficiency condensing XP Water Heater utilizes a state-of-the-art heat exchanger and control technology to provide large volumes of hot water for demanding commercial and industrial potable hot water applications. The all stainless steel water tube heat exchanger construction allows the XP Water Heater to operate in a continuous condensing mode while maximizing longevity and delivering thermal efficiencies as high as 99% when operating in low temperature applications.

A unique multi-burner design is control sequenced and modulated to produce turndown rates of up to 20:1. Precise temperature control and accurate load matching produce smooth system operation and eliminates wasteful short cycling and temperature overshooting.

Advanced Multi-Burner, Low NOx Combustion Technology n Venturi-mixing gas/air ratio system - works with variable speed blower to precisely mix gas and air throughout firing range n Fully modulating capability prevents energy-stealing short cycling and provides smooth system operation with higher overall system efficiencies Advanced Sola Control n Large touch screen user interface n Factory standard with MODBUS protocol connections n The latest in energy saving algorithms n Includes remote tank temperature control to adjust tank temperature at the water heater - modulates the water heater to maintain tank set point temperature within ±1°F n Water heater output control features 20:1 turndown ratio on models 2 million BTU/h and up, 10:1 turndown ratio on models 1.7 million BTU/h and down

HLW All-Bronze Factory-Mounted Pump(s) n Integrally mounted, wired, and controlled by the water heater control n Factory-sized for proper flow between water heater and storage tank n Allows 50 equivalent feet of piping between water heater and tank Multi-Pass/Multi-Burner Condensing Stainless Steel Heat Exchanger n Utilizes leading-edge multi-pass water tube heat exchanger to maximize heat transfer n Designed for fully condensing operation throughout the heating range n All heating surfaces are 316L stainless steel to provide a long and trouble-free service life n Saves both fuel and operating cost with every heating cycle n Impervious to thermal shock

26 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS

XWH Model Circulating A unique multi-burner design. Water Heaters

Direct Vent Flexibility n Direct vent up to 100 equivalent feet (30 meters) of pipe n Sidewall or vertical n Lower installation cost with ULC S636 approved PVC/CPVC venting material – uses CPVC for first 10 feet (3 meters) and PVC thereafter n Approved for use with UL approved AL29-4C® stainless steel venting materials Factory Start-Up Included n Required for activating warranty and assuring maximum operating performance. Contact your local sales representative or Authorized Start-Up Agent to arrange a FREE certified start-up Codes and Standards n All models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1

Up to 96% Thermal Efficiency (AHRI Certified)

5-Year Limited Heat Exchanger/1-Year Limited Parts Warranty n For complete information, consult written warranty or contact A. O. Smith

Other XP Features: n Meets ASME CSD-1/ gap codes – factory standard

n CSA certified to the ANSI Z21.10.3-CSA 4.3 water heater n Direct spark ignition standard n Factory-installed electrical disconnect n Honeywell sola control with colour touch screen LCD n ASME 160 psi working pressure display n ASME rated pressure relief valve – 125 psi · Inlet/outlet and remote tank temperature display · Logs faults, run time, cycles XP Options: · Redundant flow and low water protection - factory n ASME HLW stamped heat exchanger(s) installed LWCO and flow switch(s) n Condensate neutralization kit · Redundant ignition controls – should one burner fail n Vent termination kits remaining burners continue to heat n Skid mounted systems · Alarm buzzer

RECOVERY CAPACITIES

TEMPERATURE RISE - °F (°C) INPUT WATER MODEL 40 60 70 80 90 100 120 140 BTU/h FLOW (22) (33) (39) (44) (50) (56) (67) (78) GPH 2,662 1,775 1,521 1,331 1,183 1,065 887 761 XWH-1000 920,000 LPH 10,078 6,719 5,759 5,039 4,479 4,031 3,359 2,880 GPH 3,742 2,495 2,139 1,871 1,663 1,497 1,247 1,069 XWH-1300 1,300,000 LPH 14,167 9,444 8,095 7,083 6,296 5,667 4,722 4,048 GPH 4,904 3,269 2,802 2,452 2,180 1,962 1,635 1,401 XWH-1700 1,700,000 LPH 18,565 12,376 10,608 9,282 8,251 7,426 6,188 5,304 GPH 5,794 3,862 3,311 2,897 2,575 2,317 1,931 1,655 XWH-2000 1,999,900 LPH 21,931 14,621 12,532 10,966 9,747 8,773 7,310 6,266 GPH 7,501 5,000 4,286 3,750 3,334 3,000 2,500 2,143 XWH-2600 2,600,000 LPH 28,393 18,929 16,225 14,196 12,619 11,357 9,464 8,112 GPH 9,891 6,594 5,652 4,945 4,396 3,956 3,297 2,826 XWH-3400 3,400,000 LPH 37,441 24,961 21,395 18,721 16,641 14,976 12,480 10,697 27 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS

High Efficiency Condensing Circulating Water Heaters

SINGLE HEAT EXCHANGER BOILER SINGLE HEAT EXCHANGER MODELSSINGLE HEAT EXCHANGERDOUBLE BOILER HEAT EXCHANGER MODELS Rough In Dimensions (Single) ROUGHSINGLE IN HE DIMENSIONSAT EXCHANGERRough (SINGLE) BOILER In Dimensions (Double) ROUGH ROUGH IN DIMENSIONS IN DIMENSIONS (SINGLE) (SINGLE) Models XWH-1000 XWH-1300 XWH-1700 MODELS XWH-1000 XWH-1300 XWH-1700 MODELS XWH-2000 XWH-2600 XWH-3400 ModelsModels XWH-1000XWH-1000 XWH-1300XWH-1300 XWH- 1700 XWH-1700 DIMENSIONSDimensions INCHES CM INCHESinche CMsm INCHESm CM DIMENSIONSinchesm INCHESm CM INCHESinche CMsm INCHES CMm DimensionsDimensions inchesminchesmm m inchesminchesmm m inchesminchesmm m FLUEFlue OUTLET Outlet Diameter 6152 FLUE8 OUTLET 152 8203 Flue Outlet Diamete6r 15 861 15 852 20 8 1528 20 882 20 1003 25 DIAMETERFlue Outlet Diameter 6152 DIAMETER8 152 8203 Air Intake Diameter 6152 6 152 8203 Air Intake Diameter 6152 6 152 8203 SINGLE HEAT EXCHANGER MODELS AIR INTAKEAir Intake Diameter 6152 AIR INTAKE6 152 8203 Water Inlet6 15 6 15 8 202 inch NPT28 20 8 20 1/2 inch 10 NPT 25 DIAMETERWater Inlet DIAMETER Water Inlet 2 inch NP2 inchT2 NPT2 1/2 inch 1/2 NP inchT NPT Water Outlet 2 inch NPT2 1/2 inch NPT WATERWat erINLET Outlet 2 inch NPT 2 1/2 inch NPT WATER INLET 3 inch NPT 4 inch NPT Water Outlet 2 inch NP2 inchT2 NPT2 1/2 inch 1/2 NP inchT NPT Gas Inlet 2 inch NPT2 inch NPT WATERG OUTLETas Inlet 2 inch NPT 2 1/2 inch NPT WATER OUTLET 3 inch NPT 4 inch NPT Gas Inlet 2 inch NP2 inchT2 NPT2 inch NP inchT NPT GAS INLET A 2 inch NPT 47 2 inch11 NPT99 49 1245 57 1448 A GAS INLET 2 inch NPT 3 inch NPT A 47 47 1199 1199 49 49 1245 1245 57 57 1448 1448 A B 47 120 4967 125 571702 145 68 1727 76 1930 B A 47 119 49 125 57 145 B 67 67 1702 1702 68 68 1727 1727 76 76 1930 1930 B C 67 170 6829 173 7673 193729 737 29 737 C B 78 198 80 203 91 231 C 29 29 737273729 9 737 737 29 29 737 737 C D 29 74 2937 74 299403 74 8 965 37 940 D D 37 94038 C 96536 91 3737 94 37940 94 23 37 584294033 8 584965 24 37 610940 D E 37 94 38 97 37 94 E 23 23 584258423 D 3 58422584 56 2224 5624 22610 56 610 E F 23 58 2392 58 2429 61 9 229 9229 F F 9229 9 229 9229 G 34 92864329 4E 9 40864229 102 4134 10492 4186 1044 29 F G 9 2334 9 23 98643 23 4 864 34 864 H G 44 34 11184864351F 4 7143864 18 645 1534 61143 15 864 G H 34 86 34 86 34 86 44 1118451143 45 1143 DOUBLE HEAT EXCHANGER MODELS J H 44 1118451143 45 1143 6152 6G 10152 25 1061 25 10 2552 H J 44 112 4561 114 4552 114 6 152 6152 K J 11 61279152 1 6 279152 11 61279 52 J K K 6 1511 6 15 62791 15 1 H 2794 10 411 10 4279 10 L 12 11 305127911 1 279279 12 11 305279 L K L11 28 1112 12 28 113051 2830511 J 1 27920279 51 1912 4812 19305 48 305 L 12 31 11 28 12 31 K 12 31 12 31 13 33

28

DOUBLE HEAT EXCHANGER BOILER ROUGH IN DIMENSIONS (DOUBLE)

Models XWH-2000 XWH-2600 XWH-3400 Dimensions inchesmminchesmminchesmm Flue Outlet Diameter 8 203 8 203 10 254 Air Intake Diameter 8203 8 203 10 254 Water Inlet 3 inch NPT4 inch NPT Water Outlet 3 inch NPT4 inch NPT Gas Inlet 2 inch NPT3 inch NPT A 47 1194 49 1245 57 1448 B 78 1981 80 2032 91 2311 C 36 914 37 94037 940 D 22 559 22 55922 559 E 40 1016 41 1041 41 1041 F 7 178 6152 6 152 G 10 254 10 25410 254 H 4 102 4102 4 102 J 20 508 19 48319 483 K 12 305 12 30513 330 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS

XWH Model Circulating Water Heaters

VERSATILE MULTI-VENTING CONFIGURATIONS

DIRECT VENT, HORIZONTAL VENT VERTICAL INTAKE VERTICAL VENTING

HORIZONTAL VENTING DIRECT VENT, VERTICAL VENT HORIZONTAL INTAKE VERTICALVERTICA LVENTING VENTING HORIZONTAL VENTING DIRECTDIRECT VENVENT,T, HORIZONTAL HORIZONTAL VENT VERTICA LVENT INTAKE DIRECT VENT, VERTICAL VENT DIRECTDIRECT VENT HORIZONTAL VENT DIRECT DIRECT VENT VENT VERTICAL VERTICAL INTAKE HORIZONTAL INTAKE HORIZONTAL

Direct or sidewall vent for up to 100 equivalent feet (30 meters) of pipe. Lower installation cost with approved ULC S636 CPVC/ PVC venting material – uses CPVC for first 10 feet (3 meters) and PVC thereafter. Also approved for use with UL approved AL29-4C® stainless steel venting materials. For the detailed venting instructions review the XP water heater instruction manual at www.hotwater.com. ULC S636 APPROVED VENT AND AIR INTAKE FITTINGS

EXHAUST/VENT TERMINATIONS (PVC) PART NUMBERS AIR INTAKE TERMINATION (PVC) PART NUMBERS DIRECT VENT, VERTICAL VENT HORIZONTAL INTAKE HORIZONTAL VENTING Models Pipe Size Vertical Horizontal Models Pipe Size Combustion Air Intake (Elbow) (PVC Rain Cap) (PVC Tee w/Screens)

XWH 1000 6” 320884-000 321765-000 XWH 1000 6” 321764-000 XWH 1300 XWH 1300 XWH 1700 XWH 1700 8” 320884-001 321765-001 XWH 2000 XWH 2000 8” 321764-001 XWH 2600 XWH 2600 XWH 3400 10” 320884-002 321765-002 XWH 3400 10” 321764-002

Please note: When direct or sidewall venting, the water heater’s CSA certification requires that only the above approved vent and combustion air intake terminations be used.

GAS PRESSURE REQUIREMENTS FLOW RATE

MAXIMUM MINIMUM RECOMMENDED FLOW RATES @ 0-12 GRAINS PER GALLON TYPE MODELS SUPPLY PRESSURE SUPPLY PRESSURE OF (XWH) TEMPERATURE PRESSURE LOSS GAS INCHES INCHES MODELS GPM kPa kPa RISE (rT °F) IN FEET OF HEAD (P) W. C. W. C. XWH 1000 25 70 17.5 1000, 1300, 1700, Natural 14.0 3.49 4.0 1.0 XWH 1300 25 99 22 2000, 2500, 3400 Propane 14.0 3.49 4.0 2.0 XWH 1700 25 129 23 ELECTRICAL REQUIREMENTS XWH 2000 25 153 17.5 XWH 2600 25 198 22 SUPPLY FREQUENCY CURRENT XWH 3400 25 261 23 MODEL VOLTAGE ELECTRICAL NOTES: (HZ) (AMPS) (VOLTS) Notes: For hard water systems with water hardness greater XWH-1000 120V 60 30 A dedicated, single phase, than 12 grains per gallon, A. O. Smith recommends a water 30/60 amp circuit breaker with softener be installed and maintained. XWH-1300 120V 60 30 a grounded neutral should be provided to supply power to the The factory installed/supplied pump is sized to maintain a rT XWH-1700 120V 60 30 water heater. of 25°F through the water heater at 100% fire. In addition to XWH-2000 120V 60 60 A dedicated, single phase, the pressure loss through the water heater, the factory supplied 60/60 amp circuit breaker with pump is sized for an additional 50 equivalent feet (15 meters) of XWH-2600 120V 60 60 a grounded neutral should be piping between the water heater and a storage tank. Consult the provided to supply power to the factory for systems where the piping between the water heater XWH-3400 120V 60 60 water heater. and the tank exceed 50 equivalent feet (15 meters). 29 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS

Burkay® HW 80% thermal efficiency hot water Gas Models supply boilers.

Famous Burkay reliability. Because of their lightweight and compact design, they may be easily transported on a two-wheel dolly replacing large boilers in a much smaller space. Burkay models are for indoor use in installations requiring higher inputs up to 670,000 BTU. They can be manifolded for unlimited fire power.

All Non-Ferrous Waterways n All castings are made of bronze or brass n All water tubes are made from copper n Brazed joints or flare union construction make the boiler immune to the effects of thermal shock and thermal cycling Efficient Copper Coil Combustion Chamber n The combustion chamber is a heat exchanger formed from a two passage coil of tightly wound continuous copper tube n Water circulating through this coil surrounds the main burner and captures the radiant heat n A wrap of insulation on the outside of the coil retains the heat captured by the circulating water Copper Heat Exchanger n Directly above the coil and the main burner is a compact, horizontal, copper fin tube heat exchanger n The flue gases must pass through this efficient heat exchanger before leaving the boiler n This unique design provides maximum heat transfer and proven field durability

Thermal Balancer n Patented pump delay system that allows the boiler and pump to run simultaneously but delays pump LOW LEAD CONTENT shot off at end of heating cycle to remove usable heat from the heat exchanger and reduce the scale forming tendencies of motionless hot water

Codes and Standards n All models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 5-Year Limited Heat Exchanger/1-Year Limited Parts Warranty

APPROX. RECOVERY VENT INPUT OUTPUT HEIGHT* DIAMETER DEPTH SHIPPING MODEL 100°F (56°C) TEMP. RISE DIAMETER BTU/h BTU/h IN (CM) IN (CM) IN (CM) WEIGHT GPH (LPH) (IN) LB (KG)

1 5 HW-300 300,000 240,000 297 (1,124) 8 65 (165) 25 /4 (64) 29 /8 (75) 250 (113)

1 1 HW-399 399,000 319,200 388 (1,469) 10 57 /8 (145) 27 (69) 31 /2 (80) 301 (137)

1 1 HW-420 420,000 336,000 413 (1,563) 10 57 /8 (145) 27 (69) 31 /2 (80) 301 (137)

5 1 HW-520 520,000 416,000 515 (1,949) 10 68 /16 (174) 27 (69) 36 /2 (93) 381 (173)

5 1 HW-670 660,000** 528,000** 600 (2,271) 12 68 /16 (174) 27 (69) 36 /2 (93) 381 (173)

*Height to top of diverter **Propane: 670,000 BTU/h INPUT; 536,000 BTU/h OUTPUT.

30 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS

85% thermal efficiency Burkay Genesis® Circulating hot water heater. Water Heaters

A. O. Smith Burkay Genesis water heaters offer everything you could ask for in a non-condensing water heater. They provide a near condensing 85% thermal efficiency, outstanding venting flexibility, space-saving stackable design and an advanced electronic control system.

Electronic Control with Precise Temperature Management n Controls every electrical water heater function, including pump operation and main burner ignition, delivers precise temperature management with ±1ºF accuracy n Display panel shows current operating status and fault readings in easy-to-understand English instead of confusing numeric codes LOW LEAD CONTENT HLW n Display also shows temperature set points, outlet temperature, current inlet/outlet differential (∆T) and tank temperature n Help screens assist in water heater set-up and explain all control options n When mounted in the storage tank, the included remote temperature sensor allows the tank temperature to be set and monitored at the water heater Multiple Venting Options n All Genesis models can vent vertically in Category I with double wall “B” vent or horizontally in Category IV with AL29-4C® stainless steel vent material Copper Finned-Tube Heat Exchanger n Gasket-less glass-lined headers and copper finned tubes with extruded integral fins deliver exceptional heat transfer n ASME certified "HLW" stamped 160 psi working pressure n Copper is lightweight for easier handling and immune to thermal shock Stage Gas Firing System n Prevents short cycling and ensures smooth operation, saves fuel and extends product life n Delivers maximum output when demand is high, reduced firing rates during off peak times Factory Start-Up Included n Required for activating warranty and assuring maximum operating performance. Contact your local sales representative or Authorized Start-Up Agent to arrange a FREE certified start-up Codes and Standards n All models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 5-Year Limited Heat Exchanger/1-Year Limited Parts Warranty 31 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS

Clean burning Stainless Steel Premix Burners for smooth ignition and clean combustion

WIDTH APPROX. RECOVERY WATER GAS VENT / INTAKE INPUT HEIGHT WIDTH WITH DEPTH SHIPPING MODEL 100°F (56°C) TEMP. RISE CONNECTION CONNECTION CONNECTION BTU/h IN (CM) IN (CM) PUMP IN (CM) WEIGHT GPH (LPH) (IN) (IN) (IN) IN (CM) LB (KG)

1 1 5 1 1 GWH-400 399,000 412 (1,560) 2 1 /4 6/6 31 /2 (80) 37 /8 (96) 46 /2 (118) 22 /4 (57) 454 (206)

1 1 3 1 1 GWH-500 500,000 515 (1,949) 2 1 /4 6/6 31 /2 (80) 45 /8 (115) 54 /4 (138) 22 /4 (57) 467 (212)

1 1 3 5 1 GWH-650 650,000 670 (2,536) 2 1 /4 8/8 31 /2 (80) 56 /4 (144) 65 /8 (167) 22 /4 (57) 551 (250)

1 1 7 1 GWH-750 750,000 773 (2,926) 2 1 /4 8/8 31 /2 (80) 64 (163) 72 /8 (185) 22 /4 (57) 611 (277)

1 1 3 GWH-1000 990,000 1,020 (3,861) 2 /2 2 10/10 36 (91) 48 /2 (123) 54 /8 (138) 33 (84) 843 (382)

1 3 5 GWH-1250 1,260,000 1,298 (4,913) 2 /2 2 12/12 36 (91) 58 /4 (149) 64 /8 (164) 33 (84) 939 (426)

1 7 3 GWH-1450 1,440,000 1,484 (5,618) 2 /2 2 12/12 36 (91) 68 /8 (175) 74 /4 (190) 33 (84) 1,035 (469)

1 3 1 GWH-1800 1,800,000 1,855 (7,022) 2 /2 2 14/12 36 (91) 82 /8 (209) 88 /4 (224) 33 (84) 1,168 (530)

1 5 1 GWH-2100 2,070,000 2,133 (8,074) 2 /2 2 14/12 36 (91) 92 /8 (235) 98 /2 (250) 33 (84) 1,285 (583)

32 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS

Burkay Genesis®

Mechanical Venting Flexibility Direct-Venting Examples n Allows clean, uncontaminated air to be drawn directly into the unit n Flue gas by-products are expelled through the wall to the outside Other Genesis Features n The water heater can be vented directly through n Stage firing - 2 stages an outside wall or vertically through the roof n Sealed combustion chamber n Stainless steel burners n All bronze circulating pump (shipped loose) n On/Off switch n Adjustable high limit with manual reset n Pump delay n ASME T&P relief valve 125 psi n Factory mounted flow switch n BMS terminal strip n Contacts for air louvers n Contacts on any failure Horizontal sidewall direct- Vertical direct-venting with Genesis Options venting rear intake/exhaust horizontal combustion n air in-take rear intake/top Cupro-nickel heat exchanger exhaust n High gas pressure switch with manual reset n Low gas pressure switch with manual reset n Low water cut off with manual reset and test n Stack rack n Combustible floor shield (400 - 750) n International voltage (230V 50Hz) n Sequencing control panel with cascade/ lead-lag operation for 1-4 water heaters Vertical direct-venting top Horizontal direct-venting intake/exhaust with vertical combustion air intake top intake/rear exhaust

Conventional Venting Examples

Horizontal sidewall-venting Conventional vertical- with rear exhaust venting with top exhaust

See Installation Manual for detailed venting information and maximum/minimum intake and venting distances.

33 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS

Variable Fire (VF) Up to 87% efficient, hot water supply with modulating fire Circulating Water Heaters 4:1 turndown.

The VF Series Circulating Water Heaters are designed with one thing in mind: to provide the best value for our customer. These heaters deliver an exceptionally high thermal efficiency by combining an advanced modulating venturi-mixing gas/air ratio system with a vertical multi-pass copper heat exchanger for outstanding efficiency of up to 87%. The secret to the stunning performance of the VF Series is its flexibility. The VF is capable of firing from 100% to 25% or a 4:1 turndown ratio. The water heater’s output is based strictly on the current system demand and required BTUs needed to maintain the desired system set-point temperature. The VF’s modulating capability is virtually limitless. The VF Water Heater sets a high-efficiency standard by combining thermal efficiencies up to 87% with a smoother, more energy-efficient overall system operation.

Advanced High Efficiency n Impervious to thermal shock Combustion Technology n Heavy duty gasket-less heat n Venturi-mixing gas/air ratio exchanger design system works with variable speed blower to precisely mix gas and air Category II and IV Listed throughout firing range n Requires AL29-4C® gas tight rust n 4:1 turndown fully modulating resistant venting material capability prevents energy stealing short cycling and provides smooth Factory Start-Up Included system operation with higher n Required for activating warranty overall system efficiencies and assuring maximum operating performance. Contact your local sales Compact, Low-Profile Design representative or Authorized n Zero clearance on sides and Start-Up Agent to arrange a FREE lightweight copper heat exchanger certified start-up makes VF Series easier to move and install in limited spaces —perfect Codes and Standards for retrofits n All models meet the thermal n Fits in an elevator, ideal for boiler efficiency and standby loss rooms with limited access — only requirements of NRCan and current 24˝ wide edition of ASHRAE/IESNA 90.1 n Multiple water heater systems HLW provide increased turndown and Other VF Water Heater Features: even smoother, more efficient n ASME-rated T&P valve system operation n Factory mounted flow switch n 4 water heaters with 4:1 turndown n Contacts for 0-10 VDC BMS external = 16:1 total system turndown control ™ n Contacts for alarm or any failure High Efficiency Copper Fin Tube n All bronze factory supplied pump Heat Exchanger n Digital inlet and outlet temperature readout n Vertical heat exchanger design n Manual reset hi-limit encircles the burner with a combustion chamber that is a 360° 5-Year Limited Heat Exchanger wall of copper fin tubes /1-Year Limited Parts Warranty n All internal heat exchanger non- copper surfaces are glass lined with VF Water Heater Approved Options A. O. Smith's proprietary porcelain n For optional equipment, see VF glass coating to resist rust Water Heater spec sheet

DEPTH APPROX. RECOVERY INPUT HEIGHT WIDTH WITH DEPTH SHIPPING MODEL 100°F (56°C) TEMP. RISE BTU/h IN (CM) IN (CM) PUMP IN (CM) WEIGHT GPH (LPH) IN (CM) LB (KG)

1 1 1 3 VWH-500 500,000 527 (1,995) 44 /2 (113) 23 /8 (59) 45 /2 (116) 30 /8 (77) 573 (260)

1 1 1 3 VWH-750 750,000 791 (2,994) 52 /8 (132) 23 /8 (59) 45 /2 (116) 30 /8 (77) 622 (282)

1 3 VWH-1000 999,999 1,054 (3,990) 59 ¼ (150) 23 /8 (59) 45 ½ (116) 30 /8 (77) 662 (300)

3 1 5 VWH-1500 1,500,000 1,582 (5,989) 65 /8 (166) 27 /8 (69) 51 (130) 31 /8 (80) 1,118 (507)

5 1 5 VWH-2000 2,000,000 2,109 (7,983) 76 /8 (195) 27 /8 (69) 51 (130) 31 /8 (80) 1,187 (538) 34 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS

Variable Fire (VF) Circulating Water Heaters

Versatile Multi-Venting Configurations n Two-pipe direct-venting vertical and/or horizontal sidewall, with all combustion makeup air drawn from outside the building

50 Equivalent Feet DIRECT-VENTING (15 Meters) Exhaust 50 Equivalent Feet (15 Meters) Intake 90 Degree Elbows = 5 Feet (2 Meters) 45 Degree Elbows = 1 2 /2 Feet (1 Meter)

n Conventional venting, vertical or horizontal sidewall SIDEWALL CONVENTIONAL 50 Equivalent Feet VENTING VENTING Max (15 Meters) Please consult latest edition 90 Degree Elbows = of the Installation Manual for 5 Feet (2 Meters) detailed venting information 45 Degree Elbows = and maximum/minimum 1 2 /2 Feet (1 Meter) venting distances.

VF Electronic Control The VF Electronic Control is designed to operate all the various elements of a domestic hot water heating system. The VF Electronic Control will control temperature, operate the pump and dispense a large amount of operational data. Electronic Modulating Control n Modulates the burner to maintain tank temperature within ±1ºF n Infinite burner firing rate that modulates between 25% and 100% fire n LED display provides current water heater status in easy-to-understand English with help screens to assist should a fault occur n Controls and monitors every electrical water heater function with onboard diagnostics n Building Management System (BMS) integration with 0-10 VDC input allows BMS to control water heater firing rate

35 ELECTRIC BOILERS & HOT WATER GENERATORS Heavy-Duty Electric Designed for use as a hot water Dura-Power™ boiler for space heating applications. NW Boiler Models

­ASME Code Construction n All vessels manufactured to applicable ASME code n Vessels with maximum working pressure of 160 psi or less (standard design is for 125 psi) at 240ºF maximum temperature bear the “H” symbol per Section IV of ASME Code n Vessels with greater than 160 psi working pressure or higher than 240°F operating temperature will bear the "S" symbol per Section I of ASME Code Incoloy Immersion Heaters n Heavy-duty medium-watt density elements (3 per immersion heater) n Incoloy sheathing provides excellent protection against oxidation and scaling n Inputs range from 45 kW to 6,000 kW Control and Power Circuit Fusing n 100,000 amp I.C. cartridge-type fuses protect all elements and contactors Pilot Switch and Light n Permits manual starting and stopping of heater by interrupting power to the control circuit n Pilot light indicates when control circuit is energized Heavy-Duty Magnetic Contactors n UL-rated for 100,000 cycles Low Water Cut Off n Probe type, electric low water cut off prevent energizing of elements in the event of low water condition

Optional Goldenrod® 24-karat gold-plated 120V Control Circuit elements resist lime scale adhesion and n Powered by fused transformer sheath temperatures up to 1500ºF. Modulating Step Control n Solid-state modulating step control modulates heat input to match load 1-Year Limited Tank/1-Year Limited Parts Warranty INLET & BOILER CAPACITY MAXIMUM HEIGHT** WIDTH DEPTH MODEL OUTLET* DRAIN USG (L) KILOWATTS IN (CM) IN (CM) IN (CM) (IN) (IN) NW-37 37 (140) 180 42 (107) 32 (81) 30 (76) 3 1 NW-60 60 (227) 300 57 (145) 32 (81) 30 (76) 3 1

1 1 NW-96 96 (363) 480 69 /2 (177) 36 (91) 38 (97) 4 1 /4

1 1 NW-150 150 (568) 720 69 /2 (177) 54 (137) 44 (112) 5 1 /2

1 NW-220 220 (833) 1,140 71 (180) 60 (152) 50 (127) 5 1 /2 NW-334 334 (1,264) 1,740 99 (251) 60 (152) 50 (127) 6 2

1 NW-400 400 (1,514) 2,100 90 /2 (230) 66 (168) 56 (142) 8 2

1 NW-500 500 (1,893) 2,580 90 /2 (230) 72 (183) 62 (157) 8 2

1 NW-670 670 (2,271) 3,300 96 /2 (245) 78 (198) 68 (173) 8 2

NOTE: For boilers 3400 kW to 6000 kW, consult factory *All fittings under 4˝ will be threaded type. All fittings 4˝ and larger will be flanged. **Where overall height is a problem, a larger diameter vessel with a reduced height may be furnished 36 Field certification required on all NW installations in Canada. ELECTRIC BOILERS & HOT WATER GENERATORS Designed for utilizing steam or high Packaged Hot Water temperature boiler water as the Generating (HWG) energy source. Systems - Steam/Hot Water

These skid-mounted water heater systems are completely assembled and packaged for use. All components are sized, piped and checked at the factory before shipment. HWG systems are available in space saving vertical or horizontal models. Custom units built to order, with tank capacities up to 12,000 gallons including special control trim and special heating units can be built to design specifications on a special order basis.

Insulation Additional Features n Models are insulated with n All-copper recirculation with fiberglass to meet or exceed two bronze ball valves the thermal efficiency and n Flush-mounted T&P gauges standby loss requirements of n ASME-rated T&P valve NRCan and the most current edition of ASHRAE/IESNA 90.1 5-Year Limited Tank Integral Pump Warranty and 1-Year n System includes an integral Limited Coil Warranty bronze circulator pump Options Steam Units n Storage Tanks: 150 through n Standard steam trim consists 160 psi working pressure, of temperature control valve, ASME Section VIII construction, inlet and auxiliary steam traps, 4˝ x 6˝ hand hole, 11˝ x 15˝ inlet and auxiliary strainers, manhole, cement or epoxy steam pressure gauge with lining siphon, vacuum breaker and n Water to Water: Self actuated air vent or pneumatic operated temperature regulator and a Boiler Units bypass loop in boiler water line for regulator isolation HLW n Standard boiler water trim includes temperature control n Steam to Water: Pilot (spring, valve and boiler water air, temperature) operated temperature gauge temperature regulator Cathodic Protection Code Listing n The standard system will n Standard systems employing employ an ASME "HLW" code glass, cement or epoxy- glass-lined storage tank fitted lined tanks are fitted with with an ASME "U" code ¾" magnesium anodes to help diameter copper tube heat prevent corrosion exchanger

Gallon Sizes For GPH recoveries, n HWG models are available consult spec sheet. from 140 gallons to 12,000 gallons in both vertical and horizontal configurations

37 STORAGE TANKS Custom Small and Large Volume Storage Tanks (T, TL, TN ,TJ, TJV, TJVT, TJH, TJHT)

These storage tanks are ideal for use with gas-fired copper heat exchanger equipment and other A. O. Smith hot water systems for storage of any potable water at temperatures of 180ºF or lower. Sizes range from 80 to 12,500 gallons and custom models are available with special linings, heating coils (single-or double-wall), and accessories.

Glass-Lined Tank n Internal surfaces exposed to water are glass-lined per ASME HLW procedures n Some tanks use an NSF-approved glass-lining compound Horizontal or Vertical Mounting n "H" in the model number indicates horizontal only and "V" indicates vertical only n TJ-80 (vertical only) and TL-500 (horizontal only) Jacketed Tanks n Tanks surrounded with high-density fiberglass insulation to meet or exceed the thermal efficiency and standby loss requirements of NRCan and the most current edition of ASHRAE/IESNA 90.1 Anodic Protection n Magnesium anodes help extend tank life ASME Construction n Standard on TJV/TJH-jacketed tanks 140 gallons and larger or with an "A" in the model number HLW U LOW LEAD CONTENT n 100, 125, 150 and 160 psi maximum working pressures available 5-Year Limited Tank/1-Year Limited Parts Warranty (Except T120V & T200V models which have a 3-year limited tank warranty) Options­ n Factory jacketing and insulation n Manholes/hand holes n Factory-installed T&P valves n Angle base n Ring base n Horizontal tank saddles n Lifting lugs n Military specifications Other Linings Available n Cement formulation provides excellent corrosion protection; available on 200-gallon and larger sizes n Epoxy lining is suitable for cold or hot water storage; available on 200-gallon and larger sizes Other Constructions n Black steel, stainless and silicon bronze tanks are available for extreme severe or special applications; 38 ASME is standard STORAGE TANKS

BARE (UNINSULATED) STORAGE TANKS

APPROX. OVERALL APPROX. WORKING CAPACITY DIMENSIONS SHIPPING MODEL PRESSURE USG (L) DIA. X LENGTH WEIGHT (PSI) IN (CM) LB (KG)

1 T-80S 80 (303) 20 x 62 /8 (51 x 158) 150 170 (77)

1 T-120S 119 (450) 24 /4 x 65 (62 x 165) 150 287 (130)

3 T-120V 119 (450) 24 x 60 /4 (61 x 154) 150 270 (122)

1 T-140A 140 (530) 24 x 76 /4 (61 x 194) 125 400 (181) T-200V 188 (712) 28 x 75 (71 x 191) 125 402 (182) T-200S 200 (757) 30 x 72 (76 x 183) 150 460 (209) T-200A 200 (757) 30 x 72 (76 x 183) 125 460 (209) T-250A 250 (946) 30 x 84 (76 x 213) 125 505 (229) T-350S 350 (1,325) 36 x 88 (91 x 224) 125 670 (304) T-350A 350 (1,325) 36 x 88 (91 x 224) 125 670 (304) T-400A 400 (1,514) 36 x 97 (91 x 246) 125 775 (352) TL-500A 500 (1,893) 36 x 122 (91 x 310) 125 950 (431) TN-500A 500 (1,893) 42 x 89 (107 x 226) 125 815 (370) T-500A 500 (1,893) 48 x 74 (122 x 188) 125 950 (431) T-750A 750 (2,839) 48 x 106 (122 x 269) 125 1,290 (585) T-1000A 1,000 (3,785) 48 x 138 (122 x 351) 125 1,655 (751) Desired temperatures in A. O. Smith custom-lined hot water storage tanks can be maintained with special copper tube heating elements. Available VERTICAL JACKETED (INSULATED) STORAGE TANKS for use with steam or boiler water, single- or APPROX. OVERALL APPROX. WORKING CAPACITY DIMENSIONS SHIPPING double-wall construction. MODEL PRESSURE USG (L) DIA. X HEIGHT WEIGHT (PSI) IN (CM) LB (KG) TJ-80S 80 (303) 25 ¼ x 63 (64 x 160) 160 236 (107)

7 HD Custom Tanks Built to Order for Any Need TJ-80A 80 (303) 26 ½ x 54 /8 (67 x 139) 160 369 (167) A. O. Smith understands the variety TJV-120A 119 (450) 28 x 61 ¾ (71 x 157) 160 411 (186) 3 of special needs you may have in TJV-120M 119 (450) 29 /8 x 62 (75 x 157) 160 320 (145) 12,500 TJV-140A 140 (530) 30 x 87 (76 x 221) 125 516 (234) designing a complete commercial hot TJV-200A 200 (757) 36 x 83 (91 x 211) 125 612 (278) water supply system. We can meet just TJV-200M 180 (681) 32 x 77 (81 x 196) 160 560 (254) about any need you specify, with our (ASME) “HD” heavy duty large volume custom TJV-250A 250 (946) 36 x 96 (91 x 244) 125 900 (408) TJV-350A 350 (1,325) 42 x 97 (107 x 251) 125 1,080 (490) built storage tanks from 80 to 12,500 TJV-400A 400 (1,514) 42 x 105 (107 x 267) 125 1,282 (582) gallons, all with ASME construction, TJVT-500A 500 (1,893) 48 x 100 (122 x 254) 125 1,459 (662) and with an extensive list of options, TJV-500A 500 (1,893) 54 x 84 (137 x 213) 125 1,616 (733) including: TJV-750A 750 (2,839) 54 x 116 (137 x 295) 125 2,485 (1,127) TJV-1000A 1,000 (3,785) 54 x 150 (137 x 376) 125 3,410 (1,547) n Cement, epoxy or glass linings n Black steel tanks, stainless-steel tanks, HORIZONTAL JACKETED (INSULATED) STORAGE TANKS silicon bronze tanks APPROX. OVERALL APPROX. WORKING CAPACITY DIMENSIONS SHIPPING n Military specifications MODEL PRESSURE USG (L) DIA. X LENGTH WEIGHT (PSI) n Manholes IN (CM) LB (KG) n Hand holes TJH-200A 200 (757) 36 x 77 (91 x 196) 125 790 (358) n Lifting lugs TJH-250A 250 (946) 36 x 90 (91 x 229) 125 1,000 (454) n Steam or hot water tank heaters­ TJH-350A 350 (1,325) 42 x 93 (107 x 236) 125 1,370 (621) TJH-400A 400 (1,514) 42 x 99 (107 x 251) 125 1,476 (670) n Special and additional tank openings TJHT-500A 500 (1,893) 48 x 94 (123 x 239) 125 1,448 (657) n Leg and ring bases TJH-500A 500 (1,893) 54 x 79 (137 x 201) 125 1,541 (699) n Horizontal tank saddles TJH-750A 750 (2,839) 54 x 110 (137 x 279) 125 2,575 (1,168) n Factory-mounted T&P gauges TJH-1000A 1,000 (3,785) 54 x 143 (137 x 363) 125 3,261 (1,479)

For complete specifications on A. O. Smith Commercial Storage Tanks, consult spec sheets at www.hotwater.com. 39 REMOTE MONITORING

iCOMM™ Remote For information and ordering call 1-888-WATER02 or visit Monitoring System www.aosmithconnect.com.

Hardware iCOMM Features MODEL ITEM DESCRIPTION n Provides remote monitoring via www.aosmithconnect.com iCOMM Main communications board n E-mail and text messaging of ICMA Communications required for any iCOMM fault conditions Module installation. n Leak detection and notification n Needed if more than one Graphs unit performance and iCOMM water heater will be connected operational history IMDA Multi-Device to the control module. Order n BACnet compatibility with building Adapter 1 MDA for each water heater installed. management systems

Accessory alarm box that iCOMM Requirements iCOMM IABA includes an audible alarm and n Alarm Box Facility must have “always on” alarm light. internet (wired or wireless) n iCOMM compatible water heater Note: If using wireless internet an optional wireless adapter is needed to provide wired connection to the communications module. Recommended adapter Linksys WGA600N or equivalent. Compatible Units Include: n Cyclone® MXi (BTH models) n Cyclone Xi™ (BTX and BTXL models) n Custom Xi™ (DSE models) n Gold Series Xi™ (DVE models) n Heavy Duty Dura-Power™ Xi (DVE/DHE models) n Genesis™ Domestic Water Heaters and Boilers manufactured between July 2009 and January 2014 (GB/GW models) n VF™ Variable Fire Domestic Water Heaters and Boilers manufactured between July 2009 and January 2014 (VB/VW models)

40 REMOTE MONITORING

Introducing the BMS gateway Building Management System for control of A. O. Smith Water Heaters. BACnet and MODBUS Interface

Models: ETH-1000 Ethernet connection XLTR-1000 Serial RS-485 connection

Connect your A. O. Smith water heater to your building management system using the new Millennium control from ICC (Industrial Control Communications, Inc.)

n Works with Cyclone®, McBee DVE, Renton DSE/ DVE/DHE 150 kW or less n Use the ICC Control to enable/disable the water heater ICC ENERGY MANAGEMENT INTERFACES n Change temperature set points and differentials CONNECTION PROTOCOL PART # APPLICATION n Two models with four different configurations TYPE to connect to BACnet and MODBUS Commercial Gas - Cyclone® n 9910093000 Ethernet and Serial RS-485 versions available Serial BTH and BTX(L)-100 n (RS485) Commercial Electric - DSE, 2 wire or 4 wire RS-485 Network 9910094000 DVE, DHE 150 kW or less n Power can be supplied via the USB cable, as a BACnet Commercial Gas - Cyclone® 7-24 VDC input on the main terminal block, or 9910099000 Ethernet BTH and BTX(L)-100 via IEEE 802.3af Power over Ethernet (PoE on (IP) Commercial Electric - DSE, 9910100000 ETH-1000 only) DVE, DHE 150 kW or less n Commercial Gas - Cyclone® Configure protocols, network characteristics, and 9910096000 client/server object definitions Serial BTH and BTX(L)-100 (RS485) Commercial Electric - DSE, 9910097000 n Graphically interact with the internal database DVE, DHE 150 kW or less MODBUS in real-time via USB connection Commercial Gas - Cyclone® 9910102000 n Automatically discover and configure IP settings Ethernet BTH and BTX(L)-100 (IP) Commercial Electric - DSE, Ethernet gateways connected to the current 9910103000 DVE, DHE 150 kW or less subnet n Update firmware n Heater connection wiring supplied with unit n For questions on this product call 888-928-3702 Opt 1 n RTU and serial connect via RS-485 n Ethernet and IP connect via RJ-45

41 Innovation Continues to Lead.

For over 140 years, A. O. Smith has built a reputation for innovation and this continues to lead with our most complete line of products yet. With the trademark blend of innovative technology and energy-efficient solutions, our comprehensive line is the natural source for everything from the smallest light commercial installation all the way up to the largest multi-structure complex. We offer over 500 different commercial models, including gas-fired, oil-fired and electric configurations, ranging in capacities from 5 gallons to 12,500 gallons, with input range from 50,000 BTU to the equivalent of 2,500,000 BTU. Through an inspired blend of innovation, efficiency and over 140 years of expertise, A. O. Smith continues to set the industry standard for performance and quality of water heaters and storage tanks.

42 No Other Company is Better Qualified to Fill Your Hot Water Needs.

Knowledgeable People at Your Service To better serve our customers, A. O. Smith has over 200 manufacturer’s representatives covering Canada and the United States. In addition, we have more than 400 factory-authorized service technicians to provide reliable, immediate warranty services. We also maintain a well-staffed Customer Care and Technical Support facility in Fergus, Ontario that can provide information on A. O. Smith products, sizing, competitive analysis, etc.

A. O. Smith Customer Care Facility “Our job is to ‘smooth the road’ from proper product selection to installation, and to help customers over the ‘potholes’ of troubleshooting service.”

Stratford, Ontario Veldhoven, The Netherlands Fergus, Ontario Renton, Washington Istanbul, Turkey McBee, South Carolina Ashland City, Tennessee Nanjing, China Johnson City, Tennessee India

Juarez, Mexico

A. O. Smith has facilities located worldwide. Plants are located in strategic locations throughout North America, providing timely shipments to wholesalers. In addition, manufacturing plants are also located in Nanjing, China, to supply the ever-increasing demand for water heaters to the expanding Far East. Juarez, Mexico; Fergus and Stratford, Ontario; Veldhoven, The Netherlands and Istanbul, Turkey round out the facilities worldwide and demonstrate A. O. Smith’s global reach!

43 Notes

44 Notes

45

A. O. Smith Enterprises Ltd. 599 Hill Street West • Fergus, Ontario Canada N1M 2X1 Customer Service: 1-888-599-2837 Technical Support: 1-888-479-8324 www.hotwater.com

A. O. Smith reserves the right to make product changes or improvements at any time without notice.

Form No. CANAA80000 AUGUST, 2016 5M-MSI-0104 ­©2016 A. O. Smith Enterprises Ltd. All rights reserved. Printed in Canada