• MISSION CONSOLE GAUGE PUCK COMPASS MISSION 1 WARNING  MISSION 2C CAREFULLY READ THIS INSTRUCTION MISSION PUCK 2 MANUAL BEFORE USE, AND KEEP IT FOR MISSION 2 FUTURE REFERENCE. MISSION PUCK 3

INTRODUCTION MISSION 3 Congratulations for having chosen a console. Your console has been constructed using advanced manufacturing methods and materials, and is the result of extensive research and • TECHNICAL CHARACTERISTICS wrench; if you have a dynamometric wrench development. Correctly carry out the instructions OF THE INSTRUMENTS available, apply a closing of 8 N/m. and maintenance procedures described in this The gauge is ready for use. manual to ensure safe and enjoyable diving. Warnings omputerDive c Before using, the user must carefully ensure MISSION line that the pressure gauge is compatible with the See PUCK manual. Mission is a completely new line of consoles maximum working nominal pressure values of the regulators on which the device will be characterised by a unique design and new pressure gauge with hose instruments with superior technical features. mounted. The nominal working pressure for the pressure gauge is shown on the back of What’s more, for increased legibility, all the The instruments described in this instruction instruments are equipped with fluorescent dials. the case. manual have been tested and CE certified by After assembling the , slowly open the Special attention has been devoted to the Registered Test Center #0426 - ITALCERT, V.le ergonomics of these consoles, as can be seen tank control valve to avoid the “water hammer” Sarca, 336 - 20126 Milan – Italy for use with air, and effect resulting from the high pressure entering from their shape and the material used which, by INPP – Entrée n°3 – Port de la Pointe Rouge in addition to being highly shock resistant, the hose. Never look directly at the instrument BP 157 -13267- Marseille – France – for use with dial when opening the tank valve. affords a secure grip in every situation and . with any type of glove. In models designed for use with Nitrox, always open the valve(s) on the tank(s) very slowly to MISSION 1 Ø50 Submersible pressure gauge with brass reduce the risk of the mixture combusting. Instruments: submersible pressure gauge single-cast case; fluorescent dial with reserve Once the tank valve is open and the system is diam. 50 mm. indicator; chip-resistant dial with gasket; pressurized, reclose the valve and make sure Boot: shock-resistant elastomer. standard 7/16” UNF threaded fitting compliant there are no leaks, checking that the pressure Hose: 7/16” UNF length 90 cm. with the ISO 263 standard for connection with indicated by the needle on the pressure Dimensions: 145 x 66 x 25 mm. demand controls (regulators). gauge is stable and does not drop. If a drop in : 295 g. pressure is detected, do not dive and double Characteristics check the entire system. MISSION 2C The pressure gauge is a Category III device During the dive, remember to check the Instruments: submersible pressure gauge + as defined under European Directive 89/686/ residual air pressure frequently. compass. CEE, and complies with the specifications set The pressure gauge features a reserve supply Boot: shock-resistant elastomer. out in the harmonized European Standard indicator (area between 50 and 0 bar marked Hose: 7/16” UNF length 90 cm. EN 250/2000 for use with air. The pressure in red), designed to tell when the Dimensions: 218 x 72 x 29 mm. gauge is compliant with the specifications set tanks are nearly empty. If the gauge pointer Weight: 320 g. forth in the harmonized European Standard reaches the low-air sector during the dive, it is EN 13949:2003 for use with -rich necessary to start the ascent. MISSION PUCK 2 mixtures (Nitrox). The pressure gauge is equipped with a hose Instruments: gauge + PUCK . long enough to avoid hindering the diver during Boot: shock-resistant elastomer. Use use. It is in any case recommended to secure Hose: 7/16” UNF length 90 cm. The submersible pressure gauge is a safety the instrument using the special fasteners Dimensions: 218 x 72 x 29 mm. device for monitoring residual air pressure provided on the harness or BC. Weight: 400 g. in the tank, designed to be used as part of Protect the instrument from knocks. a SCUBA set (open-circuit, self-contained The pressure gauge must only be used with MISSION 2 underwater apparatus). CE-marked SCUBA components. Instruments: submersible pressure gauge + The pressure gauge must be assembled on depth gauge. the regulator first stage by means of the high Restrictions on use Boot: shock-resistant elastomer. pressure hose connected to the gauge. Hose: 7/16” UNF length 90 cm. This tool has been tested and certified to The pressure gauge can be used at guarantee a minimum level of functional safety Dimensions: 218 x 72 x 29 mm. below 10°C. Weight: 410 g. at a maximum depth of 50 meters, in conformity with the 89/686/EEC directive from 21 Assembly December 1989 and with EN 250 and EN 13949 MISSION PUCK 3 1) Locate the high pressure ports on the standards: Never exceed 50 meters in depth. Instruments: gauge + PUCK Dive computer + regulator first stage (refer to the instruction The pressure gauge must not be used in compass. manual of the regulator; the high pressure conditions that preclude its use (e.g.: low or no Boot: shock-resistant elastomer. ports on the first stage may be marked visibility that makes it impossible to read the Hose: 7/16” UNF length 90 cm. with the letters “HP” or with the maximum gauge) and under which it is necessary to use Dimensions: 250 x 72 x 44 mm. pressure rating) and, following the appropriate safety devices. Weight: 450 g. instructions, remove the plug from the MISSION 3 chosen port.  WARNING 2) Remove the thread protection cap before Instruments: submersible pressure gauge + The pressure gauge is designed for use depth gauge + compass. connecting the hose to the regulator first stage. with only one gas mixture. At the time of Boot: shock-resistant elastomer. purchase, the purchaser must choose the Hose: 7/16” UNF length 90 cm. 3) Screw the hose fully into the high pressure port of the regulator first stage. Tighten mix to be used: breathable air or oxygen- Dimensions: 250 x 72 x 44 mm. enriched breathable air (Nitrox). Weight: 460 g. firmly but carefully, using a 14-mm hex

 Preselected mixture - air: The pressure Storage DEPTH GAUGE gauge is designed for use with air. The air used After use, it is recommended that you rinse in the tank must comply with the EN 12021 the instrument in fresh water while it is still European standard. For safety reasons, assembled on the regulator, to prevent water Technical Characteristics mixtures other than that indicated may not be from penetrating inside the hose. • Scale 0 - 70 m. used. Allow to dry in air, and then put the instrument • Maximum depth pointer. Preselected mixture - Nitrox: The pressure away, taking care to replace the special thread gauge is designed for use exclusively with protection cap on the hose. Dial Nitrox, maximum 50% oxygen. For safety The instrument should be stored in a dry place, Diameter: 42 mm. reasons, the use of air (EN 12021) is strictly protected from heat sources and direct light, Case materials forbidden, as is the use of mixtures other than without bending the hose too tightly (minimum • High strength technopolymers. Nitrox or oxygen, which could contaminate the bend radius 20 cm). • Polycarbonate. equipment. Maintenance Precision  WARNING • Avoid exposing the instrument to direct Depth (m) Tolerance (kPa) it is strictly forbidden to switch from using sunlight or sources of heat. • Treat the gauge like a precision instrument 3 +8/-4 air to Nitrox and vice versa 6 +8/-4 and avoid bumps or knocks. 9 ±8 It must be kept in mind that the depth and • Rinse in fresh water after every dive. 15 +10/-12 duration of the dive are strictly dependent on It is recommended that the 108 O-ring Vitron 30 +10/-12 the percentage of oxygen in the breathable gasket, located on the threads of hose coupling 45 +10/-15 60 +10/-15 mixture. which connects to the pressure reducer, be replaced periodically. WARNING  Any maintenance or repairs must obligatorily Maintenance Training is compulsory before the device be performed by Mares or its authorized • Avoid exposing the instrument to direct described in these instructions may be used. personnel. sunlight or sources of heat. • Never test the instrument in contact with air, The user must have received adequate  WARNING prior training on the use of always test it in the water. equipment, both for use with air and for use Gaskets for the Nitrox pressure gauge must • Using the instrument beyond 70 m may with Nitrox. be lubricated exclusively with oxygen- cause irreparable damage. compatible grease; in the presence of • Treat the depth gauge like a precision oxygen-rich mixtures, the use of other types instrument and avoid bumps or knocks. Marking of lubricants may spark an explosion. • Rinse in fresh water after every dive. The instrument markings are located on the back of the case, and consist of the following: COMPASS • manufacturer’s logo  WARNING • names of the models: PG 2K2 – PG 2K3 – In the event of use with mixtures PG 2K4 contaminated with oil, the entire system Technical Characteristics • full scale: 360 bar / 5,000 psi must be cleaned by trained personnel • Front and side reading. • working pressure rating: 300 bar / 4,350 psi • Oil bath system with • reference standard: EN 250/2000 compensation. • reference marking: CE 0426.  WARNING • Maximum working tilt of 20°. • Dual magnet for faster response. The conformity marking indicates If Nitrox mixtures are used, the HP hose compliance with the essential health and should be replaced every two years. Dial safety requirements as per annex II D. and Diameter: 50 mm. 89/686/CEE. The number after EC identifies Scale: Bezel ring with numbering at 10° Registered Test Centre #0426 - ITALCERT V.le  WARNING intervals. Sarca, 336 - 20126 Milan - Italy, authorised to inspect the finished product under art. 11 B Under no circumstances replace the hose Case materials D.e. 89/686/CEE. fitted on the pressure gauge with one of a different type; consult your dealer or Mares • High strength technopolymers. Note for information about the type of hose to • Polycarbonate. The marking is not immediately visible be used. since the pressure gauge is equipped with Maintenance a protection cap. To see the markings • Avoid exposing the instrument to direct sunlight or sources of heat. it is necessary to remove the protective Liability covering. • Treat the compass like a precision instrument, and protect it against knocks. Mares refuses any responsibility for damages • Rinse in fresh water after every dive. caused by any use / maintenance / storage PG 2K2 & PG 2K3 & PG 2K4: made by Mares that is improper or not compliant with these  WARNING SPA - Salita Bonsen, 4 - 16035 Rapallo, Italy. instructions. The manufacturer declines all liability if the instrument is used with SCUBA Mares reserves the right to refuse to Characteristics components that are not CE marked. provide service under the warranty if the Accuracy: The guaranteed accuracy of the maintenance instructions for the afore- is: mentioned products are not followed. at 725 psi ± 72 psi at 1450 psi ± 145 psi at 2900 psi ± 145 psi at 4350 psi ± 17 psi

Connecting port airflow: <100 liters/min. at a pressure of 100 bar.

 00656 - rev. 01 - 04/08 ArtBooK 3680/08 44 2 00656 - rev. cod.

Mares S.p.A. - Salita Bonsen, 4 - 16035 RAPALLO - ITALY - Tel. +39 01852011 - Fax +39 0185669984 www.mares.com