C146-E352

For LabSolutions™ LCMS Software LC/MS/MS Method Package for

• Complete method for fast quantitative screening of 13 in meat, eggs and milk. • Increase identi cation con dence with MRM Spectrum mode and LabSolutions Insight™ Screening. • No ion-pairing reagent required. • Includes single sample preparation protocol usable for

meat, eggs and milk. LCMS-8060

Complete Solution for Quantitation and Con rmation of Aminoglycosides in Meat, Eggs and Milk

Aminoglycosides are an family widely used for the treatment of bacterial in cattle, sheep, pigs and poultry. Regulatory agencies have set maximum residue limits (MRL) for these compounds after veterinary use. Aminoglycosides are very polar compounds, and usually require the use of undesirable ion-pairing reagents with LC-MS/MS.

This Method Package is a complete solution for the simultaneous quantitative analysis of all regulated aminoglycosides by HILIC/MS/MS. It includes:

• A sample preparation protocol using mixed-mode weak cation exchange from Biotage. This protocol produces high recoveries and low matrix effects, and is adapted to meat, milk or egg samples. • A primary method for fast (< 5 min) quantitative analysis by HILIC/MS/MS with two MRMs per compound. • A second method for con rmation of identity. Using the same mobile phases and column, the gradient is modi ed and 15 optimized MRMs are acquired per compound. This enables library searching and accurate identi cation on Insight Screening using MRM Spectrum Mode (library provided).

Targeted Aminoglycosides:

• Netilmicin • (as Gentamicin C1, C1a and C2/C2a) • • Kanamycin • B • (internal standard) Streptomycin For LabSolutions LCMS Software LC/MS/MS Method Package for Aminoglycoside Antibiotics

Easy Work ow

Complete protocol includes step-by-step instructions for sample and calibration curve preparation.

Homogenization Dilution

Extraction Puri cation Analysis Data Review

Fast Quantitation and Easy Processing

Perform high-sensitivity analysis with excellent chromatography without resorting to ion-pairing reagents that foul the mass spectrometer. LabSolutions Insight provides a fast and intuitive environment for data processing and review. User-con gurable ags alert you what values are outside of QC limits, facilitating review by exception.

Increased Condence in Identication using MRM Spectrum Mode

MRM Spectrum Mode acquires up to 15 MRMs per analyte, and each transition is optimized to a speci c collision energy. Because MS duty cycle is not wasted on meaningless portions of the spectrum, information-rich spectra can be acquired in just milliseconds. The result is an unambiguous spectrum, even for trace-level components.

Note 1. LabSolutions LCMS Ver.5.91 or later is required. 2. LabSolutions Insight Library Screening Ver. 3.1 or later is required.

LabSolutions Insight and LabSolutions are trademarks of Shimadzu Corporation. Biotage logo is a registered trademark of Biotage AB.

© Shimadzu Corporation, 2018 First Edition: April 2018, Printed in Japan 3655-12704-30AIT