Phoenix Contact Automation Catalog
Total Page:16
File Type:pdf, Size:1020Kb
I/O systems in the IP20 control cabinet Inline Modular Mechatrolink bus coupler with I/Os on board The Mechatrolink bus coupler (M-Link BK) represents the link between the 120 Mechatrolink networks I and II and the wide product range of Inline modules. Mechatrolink is an open field network optimized for Motion Control. In motion field networks, the focus is on precise, synchronous controls and fast responses 72 between servos and other devices in the network. Mechatrolink and Sercos are IL MII BK DI8 DO4-PAC typical examples for motion field networks. Inline Modular Mechatrolink bus coupler, In the case of I/O field networks, the focus inputs: 24 V DC, outputs: 24 V DC, 500 mA is more on the connection of various I/O devices than on synchronization. u DeviceNetTM, PROFIBUS-DP and Ex: U DO4PWR DI4 DI4 INTERBUS are typical examples for I/O field 1 2 3 4 networks. IN6 + Together, the Inline system and the M- U S - +24 V Link BK provide solutions for the following +24 V Motion Control network requirements: solid stranded [mm2] AWG IN8 + Connection data Inline connectors U – Turn-key solution for simpler installation, - L flexible system configuration and simple Spring-cage 0.09-1.5 0.09-1.5 28-16 connection I/O mapping MechatroLink - + OUT2 U OUT3 – Overall cost reduction with clear savings M per node, low installation and startup costs Pcs. / Description Type Order No. – High-speed, high-performance control Pkt. – Precise, synchronous DIP switches on the Mechatrolink bus coupler, complete with accessories (connector and labeling field) M-Link BK allow the slave addresses, baud IL MII BK DI8 DO4-PAC 2884619 1 rate and the Mechatrolink data width to Connector set for bus coupler IL BKDIO-PLSET 2878599 1 be easily set. Labeling area, width: 12.2 mm IB IL FIELD 2 2727501 10 Marking sheet ESL 62X10 0809492 1 Flat-ribbon labeling (see CLIPLINE catalog) ZBF... The Mechatrolink bus coupler with eight integrated digital inputs and four outputs Technical data Interface save space as well as costs. This way, not Fieldbus system Mechatrolink only is fieldbus communication guaranteed, Type of connection USB type A, female connector but some automation tasks are also taken No. 2 Transmission speed Max. 10 Mbps care of at the same time. Local bus interface A width of only 80 mm saves a lot of space Type of connection Inline data jumper Power supply for module electronics on the DIN rail which can be used for other Supply voltage 24 V DC Inline system functions. In addition, the bus Range of supply voltages 19.2 V DC ... 30 V DC coupler can be operated without additional Max. current consumption Max. 0.9 A Power supply for U Max. 0.8 A DC terminals for simpler applications in "stand L Power supply for UANA Max. 0.5 A DC (observe derating) alone" mode. Digital inputs Quick start up and easy maintenance are Connection method 2, 3-wire Number of inputs 8 guaranteed through clearly arranged Typical response time Approx. 500 µs diagnosis LEDs. Name of protection Polarity protection Digital outputs The different color-coded jumpering Connection method 2, 3-wire levels on the module allow sensors and Number of outputs 4 actuators to be connected using the multi- Maximum output current per channel 500 mA Protective circuitry Short circuit and overload protection conductor system. INTERBUS data Number of connectable local bus devices 61 (On board I/Os are two devices) General data Weight 320 g Width 80 mm Ambient temperature (operation) -25°C ... 55°C Permissible humidity (operation) 95% (no condensation) 262 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert.