Four-wire Signal Conditioners

Two-wire Signal Conditioners

Function Modules

Limit Alarms

Power Transducers

Remote I/O

PC Recorder 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81(6)6659-8201 Fax: +81(6)6659-8510 Paperless Recorders URL: www.m-system.co.jp 20092009 E-mail: [email protected] Panel Meters

Lightning Surge Protectors

Electronic Actuators

Position Sensors

EC-Z906 Rev.6 January 2009

500365 ISO 9001 / ISO 14001 Certified

No matter what combination of process signal I/O, power input and mounting configuration you need, M-System can meet your requirements when others can't. Just what you would expect from the world's largest supplier of high-performance interface solutions.

Count On Us for Quality & Reliability Quality: M-System delivers more than 500,000 I/O units (300,000 units of signal conditioners) every year, and we are very proud of our manufacturing and quality control process certified by ISO 9001. Reliability: M-System does not easily stop manufacturing products once released in the market, unless we are able to supply other products of equal or better quality to replace with, because we believe it is a very important responsibility as a leading manufacturer in the world to continue to serve people who maintain the performance of process control systems. Meeting with Modern Industrial Trends Count On Us for Fast & Precise Delivery Time M-System offers an enormous selection of I/O products including signal conditioners, distributed network I/O, paperless recorders, panel meters, surge suppressors and valve actuators. Not only that, we are continuously The standard manufacturing lead time for most M-System's signal conditioners is 5 days. But more than quarter of the total shipments working on meeting modern industrial trends for , , Ethernet, DeviceNet, LONWORKS I/O, are delivered in shorter lead time, and Quick Service Center expedites MECHATROLINK devices. Working with open- more than 500 orders every month on the same day or the next day architecture networks, these products easily after ordered. Do not worry too much about the standard delivery. communicate to today's most popular HMI Just let us know 'When' you need a signal conditioner. Once a software packages and DCS/PLCs. delivery date is promised, you can of course count on us to deliver the Major product offerings of M-System are also products precisely on time. certified by various industrial standards such as CE (EMC, LVD), UL & C-UL, ATEX (CENELEC) and FM. ISO 9001 / ISO 14001 Certified

No matter what combination of process signal I/O, power input and mounting configuration you need, M-System can meet your requirements when others can't. Just what you would expect from the world's largest supplier of high-performance interface solutions.

Count On Us for Quality & Reliability Quality: M-System delivers more than 500,000 I/O units (300,000 units of signal conditioners) every year, and we are very proud of our manufacturing and quality control process certified by ISO 9001. Reliability: M-System does not easily stop manufacturing products once released in the market, unless we are able to supply other products of equal or better quality to replace with, because we believe it is a very important responsibility as a leading manufacturer in the world to continue to serve people who maintain the performance of process control systems. Meeting with Modern Industrial Trends Count On Us for Fast & Precise Delivery Time M-System offers an enormous selection of I/O products including signal conditioners, distributed network I/O, paperless recorders, panel meters, surge suppressors and valve actuators. Not only that, we are continuously The standard manufacturing lead time for most M-System's signal conditioners is 5 days. But more than quarter of the total shipments working on meeting modern industrial trends for PROFIBUS, Modbus, Ethernet, DeviceNet, LONWORKS I/O, are delivered in shorter lead time, and Quick Service Center expedites MECHATROLINK devices. Working with open- more than 500 orders every month on the same day or the next day architecture networks, these products easily after ordered. Do not worry too much about the standard delivery. communicate to today's most popular HMI Just let us know 'When' you need a signal conditioner. Once a software packages and DCS/PLCs. delivery date is promised, you can of course count on us to deliver the Major product offerings of M-System are also products precisely on time. certified by various industrial standards such as CE (EMC, LVD), UL & C-UL, ATEX (CENELEC) and FM. Products Index Page

Four-wire Signal Conditioners 6-24 • Mini-M Series Super-mini Transmitters • Mini-MW Series Space-saving Dual Output Transmitters • M6 Series Ultra-slim Transmitters Select Your Language or Region • M5/B5 Super-mini Terminal Block Transmitters • W5 Terminal Block Dual Output Transmitters • M3L Series PC Programmable Transmitters • M3S Series Super-slim Transmitters • Four-wire Fixed Range Isolators / DC mV, V, mA Input GlobalGlobal EnglishEnglish • Four-wire Temperature Transmitters www.m-system.com/english • Frequency Transmitters NorthNorth AmericaAmerica [email protected] • Strain Gauge & Potentiometer Transmitters (U.(U. S.S. A.,A., CanadaCanada & Mexico)Mexico) • AC Input Transmitters www.m-system.com/us • Pneumatic Transducers SimplifiedSimplified CChinesehinese [email protected] • Current Loop Supplies & DC Power Supplies www.m-system.com/chinese [email protected] Two-wire Signal Conditioners 25-28 TraditionalTraditional CChinesehinese KoreanKorean • B3 Series DIP-Switch Configurable Two-wire Transmitters www.m-system.com/taiwan • Two-wire Fixed Range Transmitters www.m-system.com/korean [email protected] [email protected] • Two-wire Universal Temperature Transmitter • Two-wire Temperature Transmitters PRODUCT KEY WORDS WORLD SALES CONTACTS Function Modules 29 Information on most popular M-System has a worldwide network of sales M-System products is included and representatives. Access WORLD SALES Limit Alarms 30-32 updated continuously on our web CONTACTS to find M-System’s local • M7E Series High-performance Dual / Quad Limit Alarms with LCD Display site. For more information on the representative in your area. • High-performance Dual / Quad Limit Alarms products in this catalog including • Analog Limit Alarms detailed data sheet, look into the keywords under PRODUCTS. Power Transducers 33-34 • LT Series Power Transducers • 53U Multi Power Monitor Remote I/O 35-38 • R3 Series Multi-channel, Mixed Signal Remote I/O • R5 Series Compact, Mixed Signal Remote I/O • R7 Series Compact Remote I/O PC Recorder 39-43 SERVICES & SUPPORT, • PC Recorder LITERATURE • PC Recorder MSRPAC • PC Recorder MSRpro Technical and application M-System information is available in SERVICES Web Site & SUPPORT section. Paperless Recorders 44-47 Device profiles and updates of • 73VR Paperless Recorder configurator software, demo version tryouts are downloadable. Panel Meters 48-49 ON-LINE M-SYSTEM • Bargraph Indicators SIGNAL CONDITIONERS DATA LIBRARY • Digital Panel Meters Specifications and instruction manuals for more than Lightning Surge Protectors 50-53 1000 models are downloadable at On-Line M-System Signal Conditioners DATA LIBRARY, updated weekly. • Lightning Surge Protectors Search parameters include product function and model • MD7 Series Ultra-Slim Lightning Surge Protectors number. CE, UL & C-UL are clearly indicated. Electronic Actuators & Position Sensors 54-55 Products Index Page

Four-wire Signal Conditioners 6-24 • Mini-M Series Super-mini Transmitters • Mini-MW Series Space-saving Dual Output Transmitters • M6 Series Ultra-slim Transmitters Select Your Language or Region • M5/B5 Super-mini Terminal Block Transmitters • W5 Terminal Block Dual Output Transmitters • M3L Series PC Programmable Transmitters • M3S Series Super-slim Transmitters • Four-wire Fixed Range Isolators / DC mV, V, mA Input GlobalGlobal EnglishEnglish • Four-wire Temperature Transmitters www.m-system.com/english • Frequency Transmitters NorthNorth AmericaAmerica [email protected] • Strain Gauge & Potentiometer Transmitters (U.(U. S.S. A.,A., CanadaCanada & Mexico)Mexico) • AC Input Transmitters www.m-system.com/us • Pneumatic Transducers SimplifiedSimplified CChinesehinese [email protected] • Current Loop Supplies & DC Power Supplies www.m-system.com/chinese [email protected] Two-wire Signal Conditioners 25-28 TraditionalTraditional CChinesehinese KoreanKorean • B3 Series DIP-Switch Configurable Two-wire Transmitters www.m-system.com/taiwan • Two-wire Fixed Range Transmitters www.m-system.com/korean [email protected] [email protected] • Two-wire Universal Temperature Transmitter • Two-wire Temperature Transmitters PRODUCT KEY WORDS WORLD SALES CONTACTS Function Modules 29 Information on most popular M-System has a worldwide network of sales M-System products is included and representatives. Access WORLD SALES Limit Alarms 30-32 updated continuously on our web CONTACTS to find M-System’s local • M7E Series High-performance Dual / Quad Limit Alarms with LCD Display site. For more information on the representative in your area. • High-performance Dual / Quad Limit Alarms products in this catalog including • Analog Limit Alarms detailed data sheet, look into the keywords under PRODUCTS. Power Transducers 33-34 • LT Series Power Transducers • 53U Multi Power Monitor Remote I/O 35-38 • R3 Series Multi-channel, Mixed Signal Remote I/O • R5 Series Compact, Mixed Signal Remote I/O • R7 Series Compact Remote I/O PC Recorder 39-43 SERVICES & SUPPORT, • PC Recorder LITERATURE • PC Recorder MSRPAC • PC Recorder MSRpro Technical and application M-System information is available in SERVICES Web Site & SUPPORT section. Paperless Recorders 44-47 Device profiles and updates of • 73VR Paperless Recorder configurator software, demo version tryouts are downloadable. Panel Meters 48-49 ON-LINE M-SYSTEM • Bargraph Indicators SIGNAL CONDITIONERS DATA LIBRARY • Digital Panel Meters Specifications and instruction manuals for more than Lightning Surge Protectors 50-53 1000 models are downloadable at On-Line M-System Signal Conditioners DATA LIBRARY, updated weekly. • Lightning Surge Protectors Search parameters include product function and model • MD7 Series Ultra-Slim Lightning Surge Protectors number. CE, UL & C-UL are clearly indicated. Electronic Actuators & Position Sensors 54-55 M2 Series Super-mini Transmitters W2 Series Space-saving Dual Output Transmitters

M-System's M2 Series Signal Transmitters are designed to accept Temprature & Sensor Inputs Frequency I/O MODEL MODEL FUNCTION FUNCTION a largest range of process signal inputs and provide a standard and M2 Series W2 Series M2 Series W2 Series non-standard DC output. M2XT2 ---- Thermocouple Transmitter (PC programmable) M2XPA3 ---- Frequency Transmitter (PC programmable) M2TS W2TS Thermocouple Transmitter M2XPA2 ---- Frequency Transmitter (PC programmable) The W2 Series Signal Splitters provide two isolated M2XR2 W2XR RTD Transmitter (PC programmable) M2SP W2SP Low Frequency Transmitter M2LR ---- RTD Transmitter (field- and PC-configurable) Encoder Speed Transmitter M2XRP2 ---- output of independent ranges. (PC programmable; built-in escitation) M2RS W2RS RTD Transmitter M2AP W2AP DC/Frequency Converter M2RR ---- Resistance/Resistance Converter M2PP W2PP Pulse Isolator M2XM2 W2XM Potentiometer Transmitter (PC programmable) Pulse Scaler (selectable range) Potentiometer Transmitter M2PRU ---- M2LPM ---- Both M2 and W2 use a compact-size, plug-in socket (field- and PC-configurable) base for quick installation or replacement of modules without M2MS W2MS Potentiometer Transmitter disturbing wiring M2LCS ---- Strain Gauge Transmitter Function Modules M2TG W2TG Tachogenerator Transmitter 2000 Vac isolation M2 Series M2AC W2AC AC Transmitter MODEL FUNCTION M2PA W2PA PT Transmitter (average) M2 Series W2 Series Standard DIN rail or surface mounting M2PE W2PE PT Transmitter (RMS, isolated) M2ADS ---- Adder Base socket included with modules M2CA W2CA CT Transmitter (average) M2SBS ---- Subtractor M2CE W2CE CT Transmitter (RMS) M2MLS ---- Multiplier AC Current Transmitter M2DIS ---- Divider Selectable 100-240 Vac/24 Vdc power input M2CEC ---- (clamp-on current sensor) M2REB ---- Ratio/Bias Transmitter (output bias) Selection of models by fixed range or PC programmable M2RTS ---- Ratio/Bias Transmitter (input bias) DC Supplies M2XF2 ---- Linearizer (PC programmable) CE marking and UL/C-UL Class 1 Div 2 approval M2FL ---- Square Root Extractor (selected models) MODEL M2FLS ---- Square Root Extractor (isolated) FUNCTION M2 Series W2 Series M2LMS ---- Limiter W2 Series M2D ---- Current Loop Supply (non-isolated) M2UDS ---- Inverted Output Transmitter M2D2 ---- Current Loop Supply (non-isolated) M2CDS ---- Delay Buffer EXTERNAL DIMENSIONS mm (inch) M2DYS W2DYS Current Loop Supply (isolated) M2CRS ---- Ramp Buffer M2 Series W2 Series M2DY W2DY Current Loop Supply M2AMS ---- Track/Hold M2PHS ---- Peak Hold DIN RAIL DIN RAIL M2DL ---- Current Loop Supply (square root output) 35mm wide 35mm wide Current Loop Supply M2SES2 ---- High/Low Selector (with simple loop test output) M2DNY W2DNY (with square root extractor; isolated) M2SES ---- High/Low Selector M2DYH W2DYH Current Loop Supply (applicable to HART signal)

70.5 (2.78) M2DU ---- Current Loop Supply (10-50mA loop) 89 (3.50) Installation Base 53 (2.09) 21.5 10 84 (3.31) Pneumatic Transducers MODEL (.85) (.39) 114 (4.49) [4 (.16)] FUNCTION 23 10 84 (3.31) MODEL M2 Series W2 Series (.91) (.39) 114 (4.49) [4 (.16)] FUNCTION M2 Series W2 Series Installation Base M2BS-16U0 ---- • When mounting, no extra space is needed between units. • When mounting, no extra space is needed between units. (16 positions, Screw terminal block) M2PV W2PV P/I Transducer M2BS-16U1 Installation Base ---- (16 positions, Fujitsu FCN type I/O connector) DC Inputs, Isolaters M2BS-16U2 Installation Base Limit Alarms ---- (16 positions, Omron I/O connector) MODEL MODEL MODEL Installation Base FUNCTION FUNCTION M2BS-8U1 ---- (8 positions, Fujitsu FCN type I/O connector) M2 Series W2 Series M2 Series W2 Series FUNCTION M2 Series W2 Series Installation Base M2BS-8U2 ---- M2SN ---- Input Loop Powered Isolator M2VS W2VS Signal Transmitter M2AVS ---- DC Alarm (8 positions, Omron I/O connector) M2XU ---- Universal Transmitter (PC programmable) M2VF W2VF Signal Transmitter (high speed response) M2SED ---- DC Alarm (thumbwheel setpoint adjustments) Installation Base Universal Transmitter Signal Transmitter M2BS2 ---- (for 61-UNIT series analog I/O modules) DC Alarm (thumbwheel setpoint adjustments; M2XUM ---- (PC-programmable; Modbus-RTU communication) M2VF2 ---- M2AS ---- (ultra-high speed response; isolated) DPDT output) Communication Controller Signal Transmitter (PC programmable) M2BC ---- (Mitsubishi Control & Communication Link use) M2XV2 ---- M2VV ---- Voltage Divider DC Alarm (thumbwheel setpoint adjustments; M2AS1 ---- M2LV ---- Signal Transmitter (field- and PC-configurable) single SPDT output) M2BD ---- Communication Controller (DeviceNet use)

6 7 M2 Series Super-mini Transmitters W2 Series Space-saving Dual Output Transmitters

M-System's M2 Series Signal Transmitters are designed to accept Temprature & Sensor Inputs Frequency I/O MODEL MODEL FUNCTION FUNCTION a largest range of process signal inputs and provide a standard and M2 Series W2 Series M2 Series W2 Series non-standard DC output. M2XT2 ---- Thermocouple Transmitter (PC programmable) M2XPA3 ---- Frequency Transmitter (PC programmable) M2TS W2TS Thermocouple Transmitter M2XPA2 ---- Frequency Transmitter (PC programmable) The W2 Series Signal Splitters provide two isolated M2XR2 W2XR RTD Transmitter (PC programmable) M2SP W2SP Low Frequency Transmitter M2LR ---- RTD Transmitter (field- and PC-configurable) Encoder Speed Transmitter M2XRP2 ---- output of independent ranges. (PC programmable; built-in escitation) M2RS W2RS RTD Transmitter M2AP W2AP DC/Frequency Converter M2RR ---- Resistance/Resistance Converter M2PP W2PP Pulse Isolator M2XM2 W2XM Potentiometer Transmitter (PC programmable) Pulse Scaler (selectable range) Potentiometer Transmitter M2PRU ---- M2LPM ---- Both M2 and W2 use a compact-size, plug-in socket (field- and PC-configurable) base for quick installation or replacement of modules without M2MS W2MS Potentiometer Transmitter disturbing wiring M2LCS ---- Strain Gauge Transmitter Function Modules M2TG W2TG Tachogenerator Transmitter 2000 Vac isolation M2 Series M2AC W2AC AC Transmitter MODEL FUNCTION M2PA W2PA PT Transmitter (average) M2 Series W2 Series Standard DIN rail or surface mounting M2PE W2PE PT Transmitter (RMS, isolated) M2ADS ---- Adder Base socket included with modules M2CA W2CA CT Transmitter (average) M2SBS ---- Subtractor M2CE W2CE CT Transmitter (RMS) M2MLS ---- Multiplier AC Current Transmitter M2DIS ---- Divider Selectable 100-240 Vac/24 Vdc power input M2CEC ---- (clamp-on current sensor) M2REB ---- Ratio/Bias Transmitter (output bias) Selection of models by fixed range or PC programmable M2RTS ---- Ratio/Bias Transmitter (input bias) DC Supplies M2XF2 ---- Linearizer (PC programmable) CE marking and UL/C-UL Class 1 Div 2 approval M2FL ---- Square Root Extractor (selected models) MODEL M2FLS ---- Square Root Extractor (isolated) FUNCTION M2 Series W2 Series M2LMS ---- Limiter W2 Series M2D ---- Current Loop Supply (non-isolated) M2UDS ---- Inverted Output Transmitter M2D2 ---- Current Loop Supply (non-isolated) M2CDS ---- Delay Buffer EXTERNAL DIMENSIONS mm (inch) M2DYS W2DYS Current Loop Supply (isolated) M2CRS ---- Ramp Buffer M2 Series W2 Series M2DY W2DY Current Loop Supply M2AMS ---- Track/Hold M2PHS ---- Peak Hold DIN RAIL DIN RAIL M2DL ---- Current Loop Supply (square root output) 35mm wide 35mm wide Current Loop Supply M2SES2 ---- High/Low Selector (with simple loop test output) M2DNY W2DNY (with square root extractor; isolated) M2SES ---- High/Low Selector M2DYH W2DYH Current Loop Supply (applicable to HART signal)

70.5 (2.78) M2DU ---- Current Loop Supply (10-50mA loop) 89 (3.50) Installation Base 53 (2.09) 21.5 10 84 (3.31) Pneumatic Transducers MODEL (.85) (.39) 114 (4.49) [4 (.16)] FUNCTION 23 10 84 (3.31) MODEL M2 Series W2 Series (.91) (.39) 114 (4.49) [4 (.16)] FUNCTION M2 Series W2 Series Installation Base M2BS-16U0 ---- • When mounting, no extra space is needed between units. • When mounting, no extra space is needed between units. (16 positions, Screw terminal block) M2PV W2PV P/I Transducer M2BS-16U1 Installation Base ---- (16 positions, Fujitsu FCN type I/O connector) DC Inputs, Isolaters M2BS-16U2 Installation Base Limit Alarms ---- (16 positions, Omron I/O connector) MODEL MODEL MODEL Installation Base FUNCTION FUNCTION M2BS-8U1 ---- (8 positions, Fujitsu FCN type I/O connector) M2 Series W2 Series M2 Series W2 Series FUNCTION M2 Series W2 Series Installation Base M2BS-8U2 ---- M2SN ---- Input Loop Powered Isolator M2VS W2VS Signal Transmitter M2AVS ---- DC Alarm (8 positions, Omron I/O connector) M2XU ---- Universal Transmitter (PC programmable) M2VF W2VF Signal Transmitter (high speed response) M2SED ---- DC Alarm (thumbwheel setpoint adjustments) Installation Base Universal Transmitter Signal Transmitter M2BS2 ---- (for 61-UNIT series analog I/O modules) DC Alarm (thumbwheel setpoint adjustments; M2XUM ---- (PC-programmable; Modbus-RTU communication) M2VF2 ---- M2AS ---- (ultra-high speed response; isolated) DPDT output) Communication Controller Signal Transmitter (PC programmable) M2BC ---- (Mitsubishi Control & Communication Link use) M2XV2 ---- M2VV ---- Voltage Divider DC Alarm (thumbwheel setpoint adjustments; M2AS1 ---- M2LV ---- Signal Transmitter (field- and PC-configurable) single SPDT output) M2BD ---- Communication Controller (DeviceNet use)

6 7 M6 Series Ultra-slim Transmitters

Ultra-slim, Space saving, Low power consumption. Tension-Clamp Ultra-Slim Signal Conditioners M6S Series High performance transmitters with wide selection of input and output ranges. • 5.9-mm (0.23”) wide ultra-slim design Euro terminal Screw terminal Tension-Clamp • The spring terminal provides constant force, eliminating torque

M6D Series M6N Series M6S Series management, maintenance-free for retightening Selectable connection method - Euro terminal, Screw terminal or Tension-Clamp. • High-density mounting Output load resistance 550Ω (at 4-20 mAdc) The M6 Series is designed that ensuring low power consumption. The front Power LED provided Wide selection of models by fixed range or PC programmable. User-friendly versatile programming features provided Spring Terminal W5.9 x H94 x D102mm (0.23” x 3.70” x 4.02”) The status LED for PC programmable models 5.9mm 5.9mm (0.23”) 2000 Vac isolation (0.23”) Screw Terminal Ultra-Slim Signal Conditioners M6N Series 7.5mm Optional fast response: Approx. 3.5 msec, voltage output (0.30”) • 7.5-mm (0.30”) wide ultra-slim design (M6xYV) • Self-up screws prevents falling off a terminal • High-density mounting High-density mounting: 16 units (M6D) in a space of 9.5 cm (3.75”) Optional installation base

9.5cm (3.75”) No.1 2 4

8

16 W7.5 x H102 x D102mm (0.30” x 4.02” x 4.02”) Power supplied to signal conditioners from the Screw Terminal power supply module (via the installation base). Holding up to 48 modules of M6 Series using 6 installation bases. Installation Base Euro Terminal Ultra-Slim Signal Conditioners M6D Series (Model : M6xBS) M6D EXTERNAL DIMENSIONS mm (inch) • 5.9-mm (0.23”) wide ultra-slim design 8-M3 EURO TERMINAL • Space saving Euro type terminal DIN RAIL HOOK 5678 • High-density mounting DIN RAIL 35mm wide 94 (3.70) 35.4 (1.39)

Max. 48 modules

1234 Power supply module (Model : M6xPS1) 102 (4.02) or 5.9 (.23) • When mounting, no extra space is needed between units. For redundant power supplies (Model : M6xPS2) Euro Terminal W5.9 x H94 x D102mm (0.23” x 3.70” x 4.02”)

8 9 M6 Series Ultra-slim Transmitters

Ultra-slim, Space saving, Low power consumption. Tension-Clamp Ultra-Slim Signal Conditioners M6S Series High performance transmitters with wide selection of input and output ranges. • 5.9-mm (0.23”) wide ultra-slim design Euro terminal Screw terminal Tension-Clamp • The spring terminal provides constant force, eliminating torque

M6D Series M6N Series M6S Series management, maintenance-free for retightening Selectable connection method - Euro terminal, Screw terminal or Tension-Clamp. • High-density mounting Output load resistance 550Ω (at 4-20 mAdc) The M6 Series is designed that ensuring low power consumption. The front Power LED provided Wide selection of models by fixed range or PC programmable. User-friendly versatile programming features provided Spring Terminal W5.9 x H94 x D102mm (0.23” x 3.70” x 4.02”) The status LED for PC programmable models 5.9mm 5.9mm (0.23”) 2000 Vac isolation (0.23”) Screw Terminal Ultra-Slim Signal Conditioners M6N Series 7.5mm Optional fast response: Approx. 3.5 msec, voltage output (0.30”) • 7.5-mm (0.30”) wide ultra-slim design (M6xYV) • Self-up screws prevents falling off a terminal • High-density mounting High-density mounting: 16 units (M6D) in a space of 9.5 cm (3.75”) Optional installation base

9.5cm (3.75”) No.1 2 4

8

16 W7.5 x H102 x D102mm (0.30” x 4.02” x 4.02”) Power supplied to signal conditioners from the Screw Terminal power supply module (via the installation base). Holding up to 48 modules of M6 Series using 6 installation bases. Installation Base Euro Terminal Ultra-Slim Signal Conditioners M6D Series (Model : M6xBS) M6D EXTERNAL DIMENSIONS mm (inch) • 5.9-mm (0.23”) wide ultra-slim design 8-M3 EURO TERMINAL • Space saving Euro type terminal DIN RAIL HOOK 5678 • High-density mounting DIN RAIL 35mm wide 94 (3.70) 35.4 (1.39)

Max. 48 modules

1234 Power supply module (Model : M6xPS1) 102 (4.02) or 5.9 (.23) • When mounting, no extra space is needed between units. For redundant power supplies (Model : M6xPS2) Euro Terminal W5.9 x H94 x D102mm (0.23” x 3.70” x 4.02”)

8 9 M6 Series Ultra-slim Transmitters

ANALOG INPUT TYPE PC PROGRAMMABLE TYPE

Isolator Dual Output Type Sensor Input Product Input Loop Powered Isolator Isolator Product Dual Output Signal Transmitter Product Signal transmitter Thermocouple Transmitter RTD Transmitter Potentiometer Transmitter Tension-Clamp type M6SSN-1, -2* M6SYV Tension-Clamp type M6SWVS Tension-Clamp type M6SXV M6SXT M6SXR M6SXM Screw terminal type M6NSN-1, -2* M6NYV Screw terminal type M6NWVS Screw terminal type M6NXV M6NXT M6NXR M6NXM Euro terminal type M6DSN-1, -2* M6DYV Euro terminal type M6DWVS Euro terminal type M6DXV M6DXT M6DXR M6DXM Input / Output 0-20 mAdc (4-20 mAdc) / 4-20 mAdc / 4-20 mAdc Input Input range: Input Current input range: (PR), K, E, J, T, B, R, S, N Pt100 Input range: 0-20 mAdc (4-20 mAdc) 4-20 mAdc / 1-5 Vdc -30 to +30 Vdc 0-50 mAdc (Min. span: 2 mAdc) Pt50 Ω 0-100 Ω to 0-5000 Ω 1-5 Vdc / 4-20 mAdc (Min. Span: 100 mVdc) Resistor incorporated Pt1000 Equivalent input 1-5 Vdc / 1-5 Vdc Current input: Voltage input range: Cu10 @25˚C impedance: Resistor incorporated Ω -10 to +10 Vdc / -10 to +10 Vdc -1000 to +1000 mVdc (Min. span: 100 mVdc) 250 + Load resistance -10 to +10 Vdc (Min. span: 1 Vdc) (with 20 mA input) Output 1DC current output0-20mA, 4-20mA 0-20 mA (Min. span: 1 mA) Ω ≤ Ω Load resistance≤280 Ω DC current output range Load resistance 0-600 DC current: 550 at 4-20 mA ≤ Ω DC voltage: ≥20 kΩ at -10 to +10V DC voltage output0-5 Vdc, 1-5 Vdc Load resistance 550 at 4-20 mA Load resistance≥ Ω DC voltage -10 to +10 V (Min. span: 1 V) Power input ---- 24 Vdc ± 10% 5 k output range -5 to +5 V (Min. span: 0.5 V) ± Output 2 Same range availability as Output 1. Accuracy 0.1% ≥ Ω ± Load resistance 5 k at 1-5 V Response time Approx. 20 mec. ≤0.5 sec. standard; Power input 24 Vdc 10% Power input 24 Vdc ± 10% (0-90%) Approx. 3.5 msec. optional with voltage outputAccuracy ± 0.1% Approx. 25 msec. optional with current output Accuracy Varies with the type and input / output range. For details, see the specification sheet. Response time (0-90%) ≤0.5 sec. standard; ≤ ≤ Dielectric strength 1500 Vac@1 minute 2000 Vac@1 minute Approx. 3.5 msec. optional Response time (0-90%) 0.5 sec. 1 sec. (input to output) (input to output to power to ground) Dielectric strength 2000 Vac@1 minute Dielectric strength 2000 Vac@1 minute (input to output to power to ground) CE marking Yes (input to output 1 to output 2 CE marking Yes to power to ground) * M6xSN-1: One Channel, M6xSN-2: Two Channels CE marking Yes PC PROGRAMMABLE TYPE RELATED PRODUCTS Sensor and Pulse Input CT Transmitter Limit Alarms Function Modules NEW Product Signal Transmitter Current Loop Supply Frequency Transmitter Installation Base (clamp-on current sensor) Product DC Alarm Product Function Modules Product Installation Base Tension-Clamp type M6SVS M6SDY M6SCTC M6SPA Tension-Clamp typeM6SXAS Tension-Clamp typeM6SXF1 Model No. M6SBS (M6S series), M6NBS Screw terminal type M6NVS M6NDY M6NCTC M6NPA Screw terminal type (M6N series), M6DBS (M6D series) Screw terminal typeM6NXAS M6NXF1 Euro terminal type M6DVS M6DDY M6DCTC M6DPA Euro terminal type M6DXF1 Installation Max. 48 modules (6 modules x 8 bases) Euro terminal type M6DXAS Input Input range: Input signal: 4-20 mAdc Input range: Open collector Input See M6xXV. CE marking Yes -30 to +30 Vdc Supply output: 0-10 Aac to Mechanical contact Input Current input range: 0-50 mAdc Output range See M6xXV. (Min. Span: 100 mVdc) 24-30 V at no load 0-600 Aac Voltage pulse (5 and 24 V) (Min. span: 2 mAdc) Power input 24 Vdc ± 10% Current input: Current rating: Power Supply Modules Clamp-on current sensor Resistor incorporated Accuracy Varies with the type and input / Resistor incorporated Max. 22mA (model: CLSB) optional. Voltage input range: output range. For details, Product Power Supply ModulePower Supply Module Shortcircuit protection -1000 to +1000 mVdc see the specification sheet. (dual redundant) DC current output Output range: 0-20 mA 4-20 mA Output range: 0-20 mA Output range: 2-20 mA (Min. span: 100 mVdc) Response time ≤ 0.5 sec. Tension-Clamp typeM6SPS1 M6SPS2 Min. Span: 1 mA Min. Span: 1 mA (and 0-1 mA) -10 to +10 Vdc (0-90%) without any function setting Screw terminal type Min. span: 1 mA (Min. span: 1 Vdc) M6NPS1 M6NPS2 Dielectric strength 2000 Vac@1 minute ≤ Ω Alarm point Single (Hi/Lo selectable) Euro terminal typeM6DPS1 M6DPS2 Load resistance 550 at 4-20 mA (input to output to power to ground) Supply voltage 22-27 Vdc, ripple 10% p-p max. Relay rating 250 Vac @2A DC voltage output Output range: 0-10 V Output range: 0-1 V, 0-10 V, 0-5 V, 1-5 V, -10 to +10 V, Functions Filter / Lag 2A (Total current consumed by signal 30 Vdc @2A 0-1 V, 0-10 V, 0-5 V, 1-5 V, 0-5 V -5 to +5 V · Moving average output conditioners on the base must be 2A -10 to +10 V, -5 to +5 V 1-5 V DC voltage: 0-10 V Power input 24 Vdc ± 10% · Dead time computing or less.) DC voltage: 0-10 V Min. Span: 1 V · Delay buffer (first order lag) Set accuracy ± 0.05 % Dielectric strength 2000 Vac@1 minute (power to ground) Min. Span: 1 V · Lead time computing ≤ Load resistance ≥5 kΩ at 1-5V Response time 0.2 sec. · Ramp buffer CE marking Yes ± (0 – 100% at 90% setpoint) Linearization Power input 24 Vdc 10% · User’s table linearization Accuracy ± 0.1% ± 0.5% ± 0.1% Dielectric strength 2000 Vac@1 minute · Inverted output Blank Filler Modules (input to output to power Response time ≤0.5 sec. standard; ≤100 msec. ≤1 sec. ≤0.5 sec. · Square root extraction to ground) (orifice, venturi) Product Blank Filler Module (0-90%) Approx. 3.5 msec. optional 1-cycle input pulse or less 2 with voltage output Features Failsafe operation input · X (Palmer-Bowlus flume, Tension-Clamp typeM6SDM type and range, alarm Parshall flume) Screw terminal type Approx. 25 msec. optional 5/2 M6NDM setpoint, trip action · X (triangular or v-notch weir) with current output 3/2 (High or Low) · X (rectangular weir) Euro terminal typeM6DDM Dielectric strength 2000 Vac@1 minute power / alarm ON delay, Limiter Used to fill blank solts on an (input to output to power to ground) deadband, alarm test mode · High / Low limit installation base CE marking Yes CE marking Yes CE marking Yes CE marking ----

10 11 M6 Series Ultra-slim Transmitters

ANALOG INPUT TYPE PC PROGRAMMABLE TYPE

Isolator Dual Output Type Sensor Input Product Input Loop Powered Isolator Isolator Product Dual Output Signal Transmitter Product Signal transmitter Thermocouple Transmitter RTD Transmitter Potentiometer Transmitter Tension-Clamp type M6SSN-1, -2* M6SYV Tension-Clamp type M6SWVS Tension-Clamp type M6SXV M6SXT M6SXR M6SXM Screw terminal type M6NSN-1, -2* M6NYV Screw terminal type M6NWVS Screw terminal type M6NXV M6NXT M6NXR M6NXM Euro terminal type M6DSN-1, -2* M6DYV Euro terminal type M6DWVS Euro terminal type M6DXV M6DXT M6DXR M6DXM Input / Output 0-20 mAdc (4-20 mAdc) / 4-20 mAdc / 4-20 mAdc Input Input range: Input Current input range: (PR), K, E, J, T, B, R, S, N Pt100 Input range: 0-20 mAdc (4-20 mAdc) 4-20 mAdc / 1-5 Vdc -30 to +30 Vdc 0-50 mAdc (Min. span: 2 mAdc) Pt50 Ω 0-100 Ω to 0-5000 Ω 1-5 Vdc / 4-20 mAdc (Min. Span: 100 mVdc) Resistor incorporated Pt1000 Equivalent input 1-5 Vdc / 1-5 Vdc Current input: Voltage input range: Cu10 @25˚C impedance: Resistor incorporated Ω -10 to +10 Vdc / -10 to +10 Vdc -1000 to +1000 mVdc (Min. span: 100 mVdc) 250 + Load resistance -10 to +10 Vdc (Min. span: 1 Vdc) (with 20 mA input) Output 1DC current output0-20mA, 4-20mA 0-20 mA (Min. span: 1 mA) Ω ≤ Ω Load resistance≤280 Ω DC current output range Load resistance 0-600 DC current: 550 at 4-20 mA ≤ Ω DC voltage: ≥20 kΩ at -10 to +10V DC voltage output0-5 Vdc, 1-5 Vdc Load resistance 550 at 4-20 mA Load resistance≥ Ω DC voltage -10 to +10 V (Min. span: 1 V) Power input ---- 24 Vdc ± 10% 5 k output range -5 to +5 V (Min. span: 0.5 V) ± Output 2 Same range availability as Output 1. Accuracy 0.1% ≥ Ω ± Load resistance 5 k at 1-5 V Response time Approx. 20 mec. ≤0.5 sec. standard; Power input 24 Vdc 10% Power input 24 Vdc ± 10% (0-90%) Approx. 3.5 msec. optional with voltage outputAccuracy ± 0.1% Approx. 25 msec. optional with current output Accuracy Varies with the type and input / output range. For details, see the specification sheet. Response time (0-90%) ≤0.5 sec. standard; ≤ ≤ Dielectric strength 1500 Vac@1 minute 2000 Vac@1 minute Approx. 3.5 msec. optional Response time (0-90%) 0.5 sec. 1 sec. (input to output) (input to output to power to ground) Dielectric strength 2000 Vac@1 minute Dielectric strength 2000 Vac@1 minute (input to output to power to ground) CE marking Yes (input to output 1 to output 2 CE marking Yes to power to ground) * M6xSN-1: One Channel, M6xSN-2: Two Channels CE marking Yes PC PROGRAMMABLE TYPE RELATED PRODUCTS Sensor and Pulse Input CT Transmitter Limit Alarms Function Modules NEW Product Signal Transmitter Current Loop Supply Frequency Transmitter Installation Base (clamp-on current sensor) Product DC Alarm Product Function Modules Product Installation Base Tension-Clamp type M6SVS M6SDY M6SCTC M6SPA Tension-Clamp typeM6SXAS Tension-Clamp typeM6SXF1 Model No. M6SBS (M6S series), M6NBS Screw terminal type M6NVS M6NDY M6NCTC M6NPA Screw terminal type (M6N series), M6DBS (M6D series) Screw terminal typeM6NXAS M6NXF1 Euro terminal type M6DVS M6DDY M6DCTC M6DPA Euro terminal type M6DXF1 Installation Max. 48 modules (6 modules x 8 bases) Euro terminal type M6DXAS Input Input range: Input signal: 4-20 mAdc Input range: Open collector Input See M6xXV. CE marking Yes -30 to +30 Vdc Supply output: 0-10 Aac to Mechanical contact Input Current input range: 0-50 mAdc Output range See M6xXV. (Min. Span: 100 mVdc) 24-30 V at no load 0-600 Aac Voltage pulse (5 and 24 V) (Min. span: 2 mAdc) Power input 24 Vdc ± 10% Current input: Current rating: Power Supply Modules Clamp-on current sensor Resistor incorporated Accuracy Varies with the type and input / Resistor incorporated Max. 22mA (model: CLSB) optional. Voltage input range: output range. For details, Product Power Supply ModulePower Supply Module Shortcircuit protection -1000 to +1000 mVdc see the specification sheet. (dual redundant) DC current output Output range: 0-20 mA 4-20 mA Output range: 0-20 mA Output range: 2-20 mA (Min. span: 100 mVdc) Response time ≤ 0.5 sec. Tension-Clamp typeM6SPS1 M6SPS2 Min. Span: 1 mA Min. Span: 1 mA (and 0-1 mA) -10 to +10 Vdc (0-90%) without any function setting Screw terminal type Min. span: 1 mA (Min. span: 1 Vdc) M6NPS1 M6NPS2 Dielectric strength 2000 Vac@1 minute ≤ Ω Alarm point Single (Hi/Lo selectable) Euro terminal typeM6DPS1 M6DPS2 Load resistance 550 at 4-20 mA (input to output to power to ground) Supply voltage 22-27 Vdc, ripple 10% p-p max. Relay rating 250 Vac @2A DC voltage output Output range: 0-10 V Output range: 0-1 V, 0-10 V, 0-5 V, 1-5 V, -10 to +10 V, Functions Filter / Lag 2A (Total current consumed by signal 30 Vdc @2A 0-1 V, 0-10 V, 0-5 V, 1-5 V, 0-5 V -5 to +5 V · Moving average output conditioners on the base must be 2A -10 to +10 V, -5 to +5 V 1-5 V DC voltage: 0-10 V Power input 24 Vdc ± 10% · Dead time computing or less.) DC voltage: 0-10 V Min. Span: 1 V · Delay buffer (first order lag) Set accuracy ± 0.05 % Dielectric strength 2000 Vac@1 minute (power to ground) Min. Span: 1 V · Lead time computing ≤ Load resistance ≥5 kΩ at 1-5V Response time 0.2 sec. · Ramp buffer CE marking Yes ± (0 – 100% at 90% setpoint) Linearization Power input 24 Vdc 10% · User’s table linearization Accuracy ± 0.1% ± 0.5% ± 0.1% Dielectric strength 2000 Vac@1 minute · Inverted output Blank Filler Modules (input to output to power Response time ≤0.5 sec. standard; ≤100 msec. ≤1 sec. ≤0.5 sec. · Square root extraction to ground) (orifice, venturi) Product Blank Filler Module (0-90%) Approx. 3.5 msec. optional 1-cycle input pulse or less 2 with voltage output Features Failsafe operation input · X (Palmer-Bowlus flume, Tension-Clamp typeM6SDM type and range, alarm Parshall flume) Screw terminal type Approx. 25 msec. optional 5/2 M6NDM setpoint, trip action · X (triangular or v-notch weir) with current output 3/2 (High or Low) · X (rectangular weir) Euro terminal typeM6DDM Dielectric strength 2000 Vac@1 minute power / alarm ON delay, Limiter Used to fill blank solts on an (input to output to power to ground) deadband, alarm test mode · High / Low limit installation base CE marking Yes CE marking Yes CE marking Yes CE marking ----

10 11 M5/B5 Super-mini Terminal Block Transmitters W5 Terminal Block Dual Output Transmitters

M-System's M5/B5/W5 Series Transmitters are designed to accept a M5 Series Super-mini Terminal Block Signal Transmitters wide variety of process signal input and provide a standard and EXTERNAL DIMENSIONS mm (inch) MODEL FUNCTION non-standard DC output. 7.3 (.29) 8–M3.5 SCREW M5SN Input Loop Powered Isolator M5VS Signal Transmitter

12 M5MV Signal Transmitter (narrow span input) DIN RAIL 34 35mm wide M5VF Signal Transmitter (high speed response) M5TS Thermocouple Transmitter M5RS RTD Transmitter 94 (3.70) M5MS Potentiometer Transmitter 56 M5DY Current Loop Supply 78 M5PT PT Transmitter 41 (1.61) [3.3 (.13)] 3 25

(.12) (.98) M5CT CT Transmitter • When mounting, no extra space is needed between units. M5CTC CT Transmitter (clamp-on current sensor) M5PA Frequency Transmitter

M5 Series B5 Series W5 Series B5 Series Super-mini Two-wire Terminal Block Signal Transmitters EXTERNAL DIMENSIONS mm (inch) Only 41 mm (1.61 in") deep modules can be installed anywhere, even behind the panel cover MODEL FUNCTION 7.3 (.29) 8–M3.5 SCREW B5SN Input Loop Powered Isolator The M5 Series features single channel four-wire models, while the B5 Series are two-wire models B5VS Signal Transmitter

1 2 B5TS Thermocouple Transmitter The W5 Series signal splitters provide two isolated DC outputs of independent ranges DIN RAIL 3 4 35mm wide B5RS RTD Transmitter Standard DIN rail mounting B5MS Potentiometer Transmitter 2000 Vac isolation (1500 Vac for M5 AC powered) 94 (3.70)

Selectable power input – 24 Vdc, 85-264 Vac (M5) ; 11-27 Vdc, 85-264 Vac, 110 Vdc (W5) 5 6 7 8

25 41 (1.61) [3.3 (.13)] 3 (.12) (.98) Space-saving W5 Series Terminal Block Dual Output Signal Transmitters

EXTERNAL DIMENSIONS mm (inch) MODEL FUNCTION 7.4 (.29) 5–M3.5 SCREW W5VS Signal Transmitter W5FV Signal Transmitter (field-configurble)

1 2 3 4 5 DIN RAIL W5TS Thermocouple Transmitter 35mm wide W5RS RTD Transmitter W5MS Potentiometer Transmitter W5DY Current Loop Supply 94 (3.70) W5LCS Strain Gauge Transmitter 6 (.24) W5PA Frequency Transmitter 6 7 8 9 10 11

3 45 (1.77) 41 (1.61) [3.3 (.13)] M5/B5/W5 Series low profile form (.12) 6–M3 SCREW factor fits into shallow cabinets • When mounting, no extra space is needed between units.

12 13 M5/B5 Super-mini Terminal Block Transmitters W5 Terminal Block Dual Output Transmitters

M-System's M5/B5/W5 Series Transmitters are designed to accept a M5 Series Super-mini Terminal Block Signal Transmitters wide variety of process signal input and provide a standard and EXTERNAL DIMENSIONS mm (inch) MODEL FUNCTION non-standard DC output. 7.3 (.29) 8–M3.5 SCREW M5SN Input Loop Powered Isolator M5VS Signal Transmitter

12 M5MV Signal Transmitter (narrow span input) DIN RAIL 34 35mm wide M5VF Signal Transmitter (high speed response) M5TS Thermocouple Transmitter M5RS RTD Transmitter 94 (3.70) M5MS Potentiometer Transmitter 56 M5DY Current Loop Supply 78 M5PT PT Transmitter 41 (1.61) [3.3 (.13)] 3 25

(.12) (.98) M5CT CT Transmitter • When mounting, no extra space is needed between units. M5CTC CT Transmitter (clamp-on current sensor) M5PA Frequency Transmitter

M5 Series B5 Series W5 Series B5 Series Super-mini Two-wire Terminal Block Signal Transmitters EXTERNAL DIMENSIONS mm (inch) Only 41 mm (1.61 in") deep modules can be installed anywhere, even behind the panel cover MODEL FUNCTION 7.3 (.29) 8–M3.5 SCREW B5SN Input Loop Powered Isolator The M5 Series features single channel four-wire models, while the B5 Series are two-wire models B5VS Signal Transmitter

1 2 B5TS Thermocouple Transmitter The W5 Series signal splitters provide two isolated DC outputs of independent ranges DIN RAIL 3 4 35mm wide B5RS RTD Transmitter Standard DIN rail mounting B5MS Potentiometer Transmitter 2000 Vac isolation (1500 Vac for M5 AC powered) 94 (3.70)

Selectable power input – 24 Vdc, 85-264 Vac (M5) ; 11-27 Vdc, 85-264 Vac, 110 Vdc (W5) 5 6 7 8

25 41 (1.61) [3.3 (.13)] 3 (.12) (.98) Space-saving W5 Series Terminal Block Dual Output Signal Transmitters

EXTERNAL DIMENSIONS mm (inch) MODEL FUNCTION 7.4 (.29) 5–M3.5 SCREW W5VS Signal Transmitter W5FV Signal Transmitter (field-configurble)

1 2 3 4 5 DIN RAIL W5TS Thermocouple Transmitter 35mm wide W5RS RTD Transmitter W5MS Potentiometer Transmitter W5DY Current Loop Supply 94 (3.70) W5LCS Strain Gauge Transmitter 6 (.24) W5PA Frequency Transmitter 6 7 8 9 10 11

3 45 (1.77) 41 (1.61) [3.3 (.13)] M5/B5/W5 Series low profile form (.12) 6–M3 SCREW factor fits into shallow cabinets • When mounting, no extra space is needed between units.

12 13 M3L Series PC Programmable Transmitters

“ONE-STEP CAL” Programming Without Needing a PC is also available. Enhanced PC Configurator Software Easy and precise field configurable I/O ranges PC Configurator is packed with advanced features such as: • Parameter setting are easily configured with a help of bargraphs on the screen. Enhanced PC Configurator Software • Trend graph monitoring is also possible. • Fixed analog output can be set and provided for simulation when conducting a loop test. 1500 Vac isolation • 128-point linearization and custom thermocouple/RTD tables • Fine calibration 18 mm (0.71”) thin profile DIN rail mounting • Save configuration files M-System’s M3L Series is a DIN rail mounted, universal input • Input filter transmitter with 1500 Vac isolation. • Diagnostics Sensor Information with Trend Graph Ideal for Spare Parts Stock Reduction Programs, the M3L Series supports two methods for configuring the unit. The unit’s DIP switches/control buttons simplify in-field configuration without using a PC. When identical multiple configurations are required, save yourself some time downloading the setting from PC software. M3L Series is your safe bet when you are not sure of your final I/O signals. PC Configuration When you need to apply the same setting to multiple transmitters, Typical applications include eliminating ground loops in downloading one setting from the PC is temperature measurement applications and providing an isolated MODEL FUNCTION convenient. The PC Configurator interface to data acquisition and control systems. M3LU Universal (DCmV, V, mA, T/C, RTD, Pot) Software is available to download at M-System web site. M3LV DC mV, V, mA input M3LT Thermocouple input M3LR RTD input Analog Output Calibration File Management (Compare) M3LM Potentiometer input M3LPA Frequency input M3LLC Strain gauge input M3LDY Current loop supply

SPECIFICATIONS Input type DC mV, V,mA Thermocouple RTD Pot/Resistance Frequency Strain Gauge Two-wire XMTR Model No. M3LU Model No. M3LV M3LT M3LR M3LM M3LPA M3LLC M3LDY Selectable input 0-20 mA (PR), K, E, J, T Pt 100 - Pt 1000 Pot: 80-4000 Ω Open collector 0.0-1.0 mV/V 0-20 mA ±1V B, R, S, Ni 100, Ni 120, 90 – 20k Ω (M3LM)Mechanical contact0.0-3.0 mV/V ±10V C (WRe 5-26) Ni 508.4 Resist: 10-4000Ω Voltage pulse 0.0-10.0 mV/V N, U, L Ni-Fe 604 Two-wire current 0.0-30.0 mV/V P (Platinel II) Cu 10 @25ºC RS-422 line driver P+50 Ω Max. 100 kHz Excitation supply ---- 4 V , 8 V , 12 V 0.1 to 10.0 V 24-28 Vdc Maximum current 20mA 30mA 22mA Selectable output 0-20 mA (min. 1mA span) ±2.5V (min. 250mV span) ±10V (min. 1V span) DC power input 10-32 Vdc 10-32 Vdc 10-32 Vdc 24 Vdc “ONE-STEP CAL” Configuration AC power input 100-240 Vac (available only for M3LU) 100-240 Vac ------Both input type & range and output type & range are totally independent to Accuracy * * ±0.2% * each other, which makes the calibration easier and quicker than ever. Simply by pushing the front control buttons, “ONE-STEP CAL” Response time (0-90%)≤0.2 sec. with the optimum synch filter (M3LU) * ≤10 msec. ≤1.0 sec. programming is possible without requiring personnel to have any special Operating temperature-25 to +65ºC (-13 to +149ºF) knowledge to do so. Insulation resistance ≥100MΩ with 500 Vdc Dielectric strength 1500 Vac @1 minute (input to output or power to ground) 500 Vac @1 minute (output to power) LED MODE Button Except AC powered M3LU: 2000 Vac @1 minute (input to output to power to ground) The front LED’s colors and flashing patterns CE marking Yes help you easily identify the transmitter’s UP Button status and confirm the setup actions in each Safety approval UL & C-UL (24 Vdc powered only) step of Calibration Modes. DOWN Button *Depends upon the I/O types and ranges. Refer to the data sheet for the respective model for detail. 14

15 M3L Series PC Programmable Transmitters

“ONE-STEP CAL” Programming Without Needing a PC is also available. Enhanced PC Configurator Software Easy and precise field configurable I/O ranges PC Configurator is packed with advanced features such as: • Parameter setting are easily configured with a help of bargraphs on the screen. Enhanced PC Configurator Software • Trend graph monitoring is also possible. • Fixed analog output can be set and provided for simulation when conducting a loop test. 1500 Vac isolation • 128-point linearization and custom thermocouple/RTD tables • Fine calibration 18 mm (0.71”) thin profile DIN rail mounting • Save configuration files M-System’s M3L Series is a DIN rail mounted, universal input • Input filter transmitter with 1500 Vac isolation. • Diagnostics Sensor Information with Trend Graph Ideal for Spare Parts Stock Reduction Programs, the M3L Series supports two methods for configuring the unit. The unit’s DIP switches/control buttons simplify in-field configuration without using a PC. When identical multiple configurations are required, save yourself some time downloading the setting from PC software. M3L Series is your safe bet when you are not sure of your final I/O signals. PC Configuration When you need to apply the same setting to multiple transmitters, Typical applications include eliminating ground loops in downloading one setting from the PC is temperature measurement applications and providing an isolated MODEL FUNCTION convenient. The PC Configurator interface to data acquisition and control systems. M3LU Universal (DCmV, V, mA, T/C, RTD, Pot) Software is available to download at M-System web site. M3LV DC mV, V, mA input M3LT Thermocouple input M3LR RTD input Analog Output Calibration File Management (Compare) M3LM Potentiometer input M3LPA Frequency input M3LLC Strain gauge input M3LDY Current loop supply

SPECIFICATIONS Input type DC mV, V,mA Thermocouple RTD Pot/Resistance Frequency Strain Gauge Two-wire XMTR Model No. M3LU Model No. M3LV M3LT M3LR M3LM M3LPA M3LLC M3LDY Selectable input 0-20 mA (PR), K, E, J, T Pt 100 - Pt 1000 Pot: 80-4000 Ω Open collector 0.0-1.0 mV/V 0-20 mA ±1V B, R, S, Ni 100, Ni 120, 90 – 20k Ω (M3LM)Mechanical contact0.0-3.0 mV/V ±10V C (WRe 5-26) Ni 508.4 Resist: 10-4000Ω Voltage pulse 0.0-10.0 mV/V N, U, L Ni-Fe 604 Two-wire current 0.0-30.0 mV/V P (Platinel II) Cu 10 @25ºC RS-422 line driver P+50 Ω Max. 100 kHz Excitation supply ---- 4 V , 8 V , 12 V 0.1 to 10.0 V 24-28 Vdc Maximum current 20mA 30mA 22mA Selectable output 0-20 mA (min. 1mA span) ±2.5V (min. 250mV span) ±10V (min. 1V span) DC power input 10-32 Vdc 10-32 Vdc 10-32 Vdc 24 Vdc “ONE-STEP CAL” Configuration AC power input 100-240 Vac (available only for M3LU) 100-240 Vac ------Both input type & range and output type & range are totally independent to Accuracy * * ±0.2% * each other, which makes the calibration easier and quicker than ever. Simply by pushing the front control buttons, “ONE-STEP CAL” Response time (0-90%)≤0.2 sec. with the optimum synch filter (M3LU) * ≤10 msec. ≤1.0 sec. programming is possible without requiring personnel to have any special Operating temperature-25 to +65ºC (-13 to +149ºF) knowledge to do so. Insulation resistance ≥100MΩ with 500 Vdc Dielectric strength 1500 Vac @1 minute (input to output or power to ground) 500 Vac @1 minute (output to power) LED MODE Button Except AC powered M3LU: 2000 Vac @1 minute (input to output to power to ground) The front LED’s colors and flashing patterns CE marking Yes help you easily identify the transmitter’s UP Button status and confirm the setup actions in each Safety approval UL & C-UL (24 Vdc powered only) step of Calibration Modes. DOWN Button *Depends upon the I/O types and ranges. Refer to the data sheet for the respective model for detail. 14

15 M3S Series Super-slim Transmitters

M3S Series including models available to select Enhanced PC Configurator Software universal AC/DC power input. • Parameter setting are easily configured on a PC screen. • Trend graph - Input signal to the device can be monitored. Super-space-saving 12mm (0.47") width • Fixed analog output can be set and provided for simulation when conducting a loop test. • 100-point linearization and 300-point custom thermocouple/RTD tables. Universal AC/DC power input available • Filter time constant. PC programmalble models available • Fine calibration • Save configuration files DC input model with optional fast response time Basic Setting View Loop Test View 12mm (0.47") slim profile DIN rail mounting. Selectable 100-240 Vac/24-240 Vdc universal AC/DC power input. Selection of models by fixed range or PC programmable.

EXTERNAL DIMENSIONS mm (inch) 12mm (0.47”) wide

78

56 DINRAIL 35mm wide

Fine Adjustments View Trend Graph View 62 (2.44) 106 (4.17)

12

34 12 110.5 (4.35) (.47) Detachable terminal blocks. • When mounting, no extra space is needed between units.

SPECIFICATIONS Input type DC mV, V, mA DC mV, V, mA DC mV, V, mA RTD Potentiometer Two-wire XMTR (Dual Output) Model No. M3SYVM3SVS M3SWVS M3SRS M3SMS M3SDY SPECIFICATIONS Input DC current: DC current: DC current: Pt 100, Potentiometer: Input signal: 4-20 mA, 0-20 mA, resistor incorporated resistor incorporated Pt 50 Ω, 100 Ω – 10k Ω 4-20 mAdc Input type DC mV, V, mA Thermocouple RTD Potentiometer ±20 mA 4-20 mA, etc. 4-20 mA, etc. Ni 508.4 Ω Supply output: Model No. M3SXV M3SXT M3SXR M3SXM 24-28 Vdc Input DC current input range: (PR), K, E, J, T, Pt 100, 0-100 Ω to 0-5000 Ω DC voltage: DC voltage input range:DC voltage: with no load 0-50 mA (min. 2mA span) B, R, S, N Pt 50 Ω, 0-10 V, 0-5 V, -300 to +300 V -30 to +30 V Current rating: ± ± Pt 1000, 1-5 V, 10 V, 5 V (min. 3mV span) (min. 100mV span) Max. 22 mAdc DC voltage input range: Cu 10 @25ºC DC current output 4-20 mA, 0-20 mA Output range: 0-20 mAOutput 1, 2: Output range: 0-20 mA 4-20mA -1000 to +1000 mV (min. 1mA span) 4-20 mA, 0-20 mA (min. 1mA span) (min. 100mV span) -10 to +10 V (min. 1V span) Load resistance ≤750 Ω ≤550 Ω at 4-20 mA ≤280 Ω ≤550 Ω at 4-20 mA ≤550 Ω DC voltage output 0-10 V, 1-5 V, Output range: Output 1, 2: Output range: -10 to +11 V 0-10 V, 0-5 V, DC current output Output range: 0-20 mA (min. 1mA span) ±10 V -10 to +11 V 0-5 V, 1-5 V (min. 5mV span) 1-5 V Load resistance 550 Ω at 4-20 mA (min. 5mV span) DC voltage output Output range: -10 to +10 V (min. 1V span) , -5 to +5 V (min. 0.5V span) Load resistance ≥5k Ω at 1-5 V ≥5k Ω at 1-5 V ≥5k Ω ≥5k Ω at 1-5 V ≥5k Ω at 1-5 V Load resistance 5 kΩ at 1-5 V Power input 24 Vdc 100-240 Vac, 24-240 Vdc 24 Vdc Power input 24 Vdc (100-240 Vac, 24-240 Vdc pending) 100-240 Vac, 24-240 Vdc Accuracy ±0.1% ±0.2% ±0.1% ±0.1% Accuracy * Response time ≤0.5 sec. ≤0.5 sec. ≤0.5 sec. ≤0.5 sec. ≤100 msec. Response time (0-90%)≤0.5 sec. ≤1 sec. (0-90%) 25 msec. optional 3.5 msec. optional 25 msec. optional Operating temperature-10 to +55˚C (14 to 131˚F) Operating temperature-10 to +55˚C (14 to 131˚F) (Min. -20˚C or -4˚F for M3SWVS and M3SDY) Insulation resistance ≥100MΩ with 500 Vdc ≥ Ω Insulation resistance 100M with 500 Vdc Dielectric strength 2000 Vac @1 minute (input to output to power to ground) Dielectric strength 2000 Vac @1 minute (input to output to power to ground) CE marking Yes CE marking Yes *Depends upon the I/O types and ranges. Refer to the data sheet for the respective model for detail.

16

17 M3S Series Super-slim Transmitters

M3S Series including models available to select Enhanced PC Configurator Software universal AC/DC power input. • Parameter setting are easily configured on a PC screen. • Trend graph - Input signal to the device can be monitored. Super-space-saving 12mm (0.47") width • Fixed analog output can be set and provided for simulation when conducting a loop test. • 100-point linearization and 300-point custom thermocouple/RTD tables. Universal AC/DC power input available • Filter time constant. PC programmalble models available • Fine calibration • Save configuration files DC input model with optional fast response time Basic Setting View Loop Test View 12mm (0.47") slim profile DIN rail mounting. Selectable 100-240 Vac/24-240 Vdc universal AC/DC power input. Selection of models by fixed range or PC programmable.

EXTERNAL DIMENSIONS mm (inch) 12mm (0.47”) wide

78

56 DINRAIL 35mm wide

Fine Adjustments View Trend Graph View 62 (2.44) 106 (4.17)

12

34 12 110.5 (4.35) (.47) Detachable terminal blocks. • When mounting, no extra space is needed between units.

SPECIFICATIONS Input type DC mV, V, mA DC mV, V, mA DC mV, V, mA RTD Potentiometer Two-wire XMTR (Dual Output) Model No. M3SYVM3SVS M3SWVS M3SRS M3SMS M3SDY SPECIFICATIONS Input DC current: DC current: DC current: Pt 100, Potentiometer: Input signal: 4-20 mA, 0-20 mA, resistor incorporated resistor incorporated Pt 50 Ω, 100 Ω – 10k Ω 4-20 mAdc Input type DC mV, V, mA Thermocouple RTD Potentiometer ±20 mA 4-20 mA, etc. 4-20 mA, etc. Ni 508.4 Ω Supply output: Model No. M3SXV M3SXT M3SXR M3SXM 24-28 Vdc Input DC current input range: (PR), K, E, J, T, Pt 100, 0-100 Ω to 0-5000 Ω DC voltage: DC voltage input range:DC voltage: with no load 0-50 mA (min. 2mA span) B, R, S, N Pt 50 Ω, 0-10 V, 0-5 V, -300 to +300 V -30 to +30 V Current rating: ± ± Pt 1000, 1-5 V, 10 V, 5 V (min. 3mV span) (min. 100mV span) Max. 22 mAdc DC voltage input range: Cu 10 @25ºC DC current output 4-20 mA, 0-20 mA Output range: 0-20 mAOutput 1, 2: Output range: 0-20 mA 4-20mA -1000 to +1000 mV (min. 1mA span) 4-20 mA, 0-20 mA (min. 1mA span) (min. 100mV span) -10 to +10 V (min. 1V span) Load resistance ≤750 Ω ≤550 Ω at 4-20 mA ≤280 Ω ≤550 Ω at 4-20 mA ≤550 Ω DC voltage output 0-10 V, 1-5 V, Output range: Output 1, 2: Output range: -10 to +11 V 0-10 V, 0-5 V, DC current output Output range: 0-20 mA (min. 1mA span) ±10 V -10 to +11 V 0-5 V, 1-5 V (min. 5mV span) 1-5 V Load resistance 550 Ω at 4-20 mA (min. 5mV span) DC voltage output Output range: -10 to +10 V (min. 1V span) , -5 to +5 V (min. 0.5V span) Load resistance ≥5k Ω at 1-5 V ≥5k Ω at 1-5 V ≥5k Ω ≥5k Ω at 1-5 V ≥5k Ω at 1-5 V Load resistance 5 kΩ at 1-5 V Power input 24 Vdc 100-240 Vac, 24-240 Vdc 24 Vdc Power input 24 Vdc (100-240 Vac, 24-240 Vdc pending) 100-240 Vac, 24-240 Vdc Accuracy ±0.1% ±0.2% ±0.1% ±0.1% Accuracy * Response time ≤0.5 sec. ≤0.5 sec. ≤0.5 sec. ≤0.5 sec. ≤100 msec. Response time (0-90%)≤0.5 sec. ≤1 sec. (0-90%) 25 msec. optional 3.5 msec. optional 25 msec. optional Operating temperature-10 to +55˚C (14 to 131˚F) Operating temperature-10 to +55˚C (14 to 131˚F) (Min. -20˚C or -4˚F for M3SWVS and M3SDY) Insulation resistance ≥100MΩ with 500 Vdc ≥ Ω Insulation resistance 100M with 500 Vdc Dielectric strength 2000 Vac @1 minute (input to output to power to ground) Dielectric strength 2000 Vac @1 minute (input to output to power to ground) CE marking Yes CE marking Yes *Depends upon the I/O types and ranges. Refer to the data sheet for the respective model for detail.

16

17 Four-wire Fixed Range Isolators / DC mV, V, mA Input Four-wire Temperature Transmitters

Compact Plug-in Design Low-profile, Low Cost Type Compact Plug-in Design M2TS Thermocouple input, Single output W2TS Thermocouple input, Two isolated outputs M2RS RTD input, Single output W2RS RTD input, Two isolated outputs W2XR RTD input, Two isolated outputs, PC programmable • Linearization, burnout protection, cold junction compensation M2 Series W2 Series M5 Series W5 Series (T/C input) standard M2 Series W2 Series • Optional 25 msec. response time selectable M2VS Single output M5VS Single output • Two independent ranges can be specified with the signal splitter. ≤ µ M2VF Single output, 180 sec. response M5MV Single output, narrow span Ultra-slim, Space-saving W2VS Two isolated outputs M5VF Single output, ≤150 µsec. response W2VF Two isolated outputs, ≤180 µsec. response W5VS Two isolated outputs M6SXT Thermocouple input, Tension-Clamp M6SXR RTD input, Tension-Clamp • Wide selection of input and output ranges W5FV Two isolated outputs, field-selectable I/O M6NXT Thermocouple input, Screw terminal M6NXR RTD input, Screw terminal • Optional 25 msec. response time selectable for M2VS and W2VS • 41 mm (1.6”) deep M6DXT Thermocouple input, Euro terminal M6DXR RTD input, Euro terminal • Two independent ranges can be specified with the signal splitter. • Two independent ranges can be specified with the signal splitter. • 5.9 mm (.23”) wide for M6S Series and M6D Series 7.5 mm (.30”) wide for M6N Series Ultra-slim, Space-saving • Linearization, burnout protection, cold junction compensation (T/C input) standard • PC programmable M6 Series M6SVS Single output, Tension-Clamp M6SWVS Two isolated outputs, Tension-Clamp M6NVS Single output, Screw terminal M6NWVS Two isolated outputs, Screw terminal Low-profile, Low Cost Type M6DVS Single output, Euro terminal M6DWVS Two isolated outputs, Euro terminal M5TS Thermocouple input, Single output • 5.9 mm (.23”) wide for M6S Series and M6D Series, 7.5 mm (.30”) wide for M6N Series W5TS Thermocouple input, Two isolated outputs • Optional fast response time selectable M5RS RTD input, Single output • Two independent ranges can be specified with the signal splitter. W5RS RTD input, Two isolated outputs M6 Series • 41 mm (1.6”) deep SPECIFICATIONS • Linearization, burnout protection, cold junction compensation Series M2 / W2 Series M6 Series M5 / W5 Series (T/C input) standard Single output model M2VS M2VF M6xVS M5VS/M5MV M5VF • Optional 25 msec. response time selectable Dual output model W2VS W2VFM6xWVS W5VS W5FV • Two independent ranges can be specified with the signal splitter. M5 Series W5 Series DC voltage input -300 to +300 V -300 to +300 V -300 to +300 V -300 to +300 V -30 to +30 V Field-selectable (Specific range of) (±100mV/M5MV) 0-60 mV, 0-100 mV, 0-1 V, 0-5 V, 1-5 V, SPECIFICATIONS Minimum span 3mV 1V 100mV 100mV 1V ± ± (5mV/M5MV) 0-10 V, 5V, 10V Series M2 / W2 Series M6 Series M5 / W5 Series DC current input Resistor attached to the input terminals. Resistor incorporated Resistor incorporated Field-selectable Single output model M2TS M2RS M6xXTM6xXR M5TS M5RS 4-20 mA, 0-10 mA, 10-50 mA, etc. 4-20 mA, 0-10 mA, etc. 4-20 mA, 0-10 mA, 10-50 mA, etc.4-20 mA, 0-20 mA, 0-10 mA Dual output model W2TS W2RS W5TS W5RS DC current output 0-20 mA -10 to +20 mA 0-20 mA 0-20 mA Out 1: Field-selectable Input T/C T/C T/CRTD T/C RTD ± (Specific range of) e.g. 4-20 mA e.g. 1mA Min. span: 1mA (M6xVS) e.g. 4-20 mA 4-20 mA, 0-20 mA DC current output 0-20 mA 0-20 mA 0-20 mA 4-20 mA, 0-20 mA (Specific range of) e.g. 4-20 mA e.g. 4-20 mA Minimum span 1mA 1mAFixed (M6xWVS) 1mA Out 2: Fixed Minimum span 1mA 1mA 1mA Load resistance ≤750Ω at 4-20 mA ≤550Ω at 4-20 mA (M6xVS)≤550Ω at 4-20 mA ≤550Ω at 4-20 mA ≤ Ω ≤ Ω ≤ Ω Load resistance, Out 2 ≤350Ω at 4-20 mA ≤280Ω (M6xWVS) ≤550Ω at 4-20 mA ≤550Ω at 4-20 mA Load resistance 750 at 4-20 mA 550 at 4-20 mA 550 at 4-20 mA Load resistance, Out 2 ≤350Ω at 4-20 mA ---- ≤550Ω at 4-20 mA DC voltage output -10 to +12 V (+10V for Output 2) 0-10 V 0-10 V (-10 to +12 V for W5VS) Out 1: Field-selectable (Specific range of) e.g. 1-5 V, 0-10 V Min. span: 1V (M6xVS) e.g. 1-5 V, 0-10 V 0-10 V, 0-5 V, 1-5 V DC voltage output -10 to +12 V (+10V for Output 2) -10 to +11 V (Min. span: 1V) 0-10 V (-10 to +12 V for W5) 0-5 V, 1-5 V ±5V, ±10V (Specific range of) e.g. 1-5 V, 0-10 V -5 to +5 V (Min. span: 0.5V) e.g. 1-5 V, 0-10 V Minimum span 5mV Fixed (M6xWVS) 1V (5mV for W5VS) Out 2: Fixed Minimum span 5mV 1V (5mV for W5) Load resistance ≥5kΩ at 1-5 V ≥5kΩ at 1-5 V ≥500Ω at 1-5 V ≥500Ω at 1-5 V Load resistance ≥5kΩ at 1-5 V ≥5kΩ at 1-5 V ≥500Ω at 1-5 V Power input 24 Vdc or 100-240 Vac 24 Vdc 24 Vdc or 100-240 Vac Power input 24 Vdc or 100-240 Vac 24 Vdc 24 Vdc or 100-240 Vac Accuracy ±0.1% ±0.1% ±0.1% ±0.1% ±0.1% ±0.1% Accuracy ±0.4% ±0.2% Varies with the type and K, E, J:± 0.1% FS or 0.2ºC±0.2% Response time ≤0.5 sec. ≤180 µsec. ≤0.5 sec. ≤0.5 sec. ≤150 µsec. ≤0.5 sec. input / output range. T, N:± 0.2% FS or 0.2ºC (0-90%) 25 msec. optional 3.5 msec. optional (25 msec.25 msec./≤1 msec. For details, see the specification sheet. B, R, S: ±0.3% FS for M6xVS Current output) Response time (0-90%) ≤0.5 sec. standard; 25 msec. optional ≤0.5 sec. ≤0.5 sec. standard; 25 msec. optional Operating temperature -5 to +55ºC (23 to 131ºF) (Min. -20ºC or -44ºF for M6) Operating temperature -5 to +55ºC (23 to 131ºF) -20 to +55ºC (-4 to 131ºF) -5 to +55ºC (23 to 131ºF) Insulation resistance ≥100MΩ with 500 Vdc Insulation resistance ≥100MΩ with 500 Vdc Dielectric strength 2000 Vac @1 minute (input to output to power to ground) 2000 Vac @1 minute (DC powered M5) Dielectric strength 2000 Vac @1 minute (input to output to power to ground) 2000 Vac @1 minute (DC powered M5) 1500 Vac @1 minute (AC powered M5) 1500 Vac @1 minute (AC powered M5) CE marking Yes Yes Yes (24 Vdc powered) CE marking Yes Yes Yes (24 Vdc powered) Safety approval UL & C-UL nonincendive ------Safety approval UL & C-UL nonincendive ------

18 19 Four-wire Fixed Range Isolators / DC mV, V, mA Input Four-wire Temperature Transmitters

Compact Plug-in Design Low-profile, Low Cost Type Compact Plug-in Design M2TS Thermocouple input, Single output W2TS Thermocouple input, Two isolated outputs M2RS RTD input, Single output W2RS RTD input, Two isolated outputs W2XR RTD input, Two isolated outputs, PC programmable • Linearization, burnout protection, cold junction compensation M2 Series W2 Series M5 Series W5 Series (T/C input) standard M2 Series W2 Series • Optional 25 msec. response time selectable M2VS Single output M5VS Single output • Two independent ranges can be specified with the signal splitter. ≤ µ M2VF Single output, 180 sec. response M5MV Single output, narrow span Ultra-slim, Space-saving W2VS Two isolated outputs M5VF Single output, ≤150 µsec. response W2VF Two isolated outputs, ≤180 µsec. response W5VS Two isolated outputs M6SXT Thermocouple input, Tension-Clamp M6SXR RTD input, Tension-Clamp • Wide selection of input and output ranges W5FV Two isolated outputs, field-selectable I/O M6NXT Thermocouple input, Screw terminal M6NXR RTD input, Screw terminal • Optional 25 msec. response time selectable for M2VS and W2VS • 41 mm (1.6”) deep M6DXT Thermocouple input, Euro terminal M6DXR RTD input, Euro terminal • Two independent ranges can be specified with the signal splitter. • Two independent ranges can be specified with the signal splitter. • 5.9 mm (.23”) wide for M6S Series and M6D Series 7.5 mm (.30”) wide for M6N Series Ultra-slim, Space-saving • Linearization, burnout protection, cold junction compensation (T/C input) standard • PC programmable M6 Series M6SVS Single output, Tension-Clamp M6SWVS Two isolated outputs, Tension-Clamp M6NVS Single output, Screw terminal M6NWVS Two isolated outputs, Screw terminal Low-profile, Low Cost Type M6DVS Single output, Euro terminal M6DWVS Two isolated outputs, Euro terminal M5TS Thermocouple input, Single output • 5.9 mm (.23”) wide for M6S Series and M6D Series, 7.5 mm (.30”) wide for M6N Series W5TS Thermocouple input, Two isolated outputs • Optional fast response time selectable M5RS RTD input, Single output • Two independent ranges can be specified with the signal splitter. W5RS RTD input, Two isolated outputs M6 Series • 41 mm (1.6”) deep SPECIFICATIONS • Linearization, burnout protection, cold junction compensation Series M2 / W2 Series M6 Series M5 / W5 Series (T/C input) standard Single output model M2VS M2VF M6xVS M5VS/M5MV M5VF • Optional 25 msec. response time selectable Dual output model W2VS W2VFM6xWVS W5VS W5FV • Two independent ranges can be specified with the signal splitter. M5 Series W5 Series DC voltage input -300 to +300 V -300 to +300 V -300 to +300 V -300 to +300 V -30 to +30 V Field-selectable (Specific range of) (±100mV/M5MV) 0-60 mV, 0-100 mV, 0-1 V, 0-5 V, 1-5 V, SPECIFICATIONS Minimum span 3mV 1V 100mV 100mV 1V ± ± (5mV/M5MV) 0-10 V, 5V, 10V Series M2 / W2 Series M6 Series M5 / W5 Series DC current input Resistor attached to the input terminals. Resistor incorporated Resistor incorporated Field-selectable Single output model M2TS M2RS M6xXTM6xXR M5TS M5RS 4-20 mA, 0-10 mA, 10-50 mA, etc. 4-20 mA, 0-10 mA, etc. 4-20 mA, 0-10 mA, 10-50 mA, etc.4-20 mA, 0-20 mA, 0-10 mA Dual output model W2TS W2RS W5TS W5RS DC current output 0-20 mA -10 to +20 mA 0-20 mA 0-20 mA Out 1: Field-selectable Input T/C T/C T/CRTD T/C RTD ± (Specific range of) e.g. 4-20 mA e.g. 1mA Min. span: 1mA (M6xVS) e.g. 4-20 mA 4-20 mA, 0-20 mA DC current output 0-20 mA 0-20 mA 0-20 mA 4-20 mA, 0-20 mA (Specific range of) e.g. 4-20 mA e.g. 4-20 mA Minimum span 1mA 1mAFixed (M6xWVS) 1mA Out 2: Fixed Minimum span 1mA 1mA 1mA Load resistance ≤750Ω at 4-20 mA ≤550Ω at 4-20 mA (M6xVS)≤550Ω at 4-20 mA ≤550Ω at 4-20 mA ≤ Ω ≤ Ω ≤ Ω Load resistance, Out 2 ≤350Ω at 4-20 mA ≤280Ω (M6xWVS) ≤550Ω at 4-20 mA ≤550Ω at 4-20 mA Load resistance 750 at 4-20 mA 550 at 4-20 mA 550 at 4-20 mA Load resistance, Out 2 ≤350Ω at 4-20 mA ---- ≤550Ω at 4-20 mA DC voltage output -10 to +12 V (+10V for Output 2) 0-10 V 0-10 V (-10 to +12 V for W5VS) Out 1: Field-selectable (Specific range of) e.g. 1-5 V, 0-10 V Min. span: 1V (M6xVS) e.g. 1-5 V, 0-10 V 0-10 V, 0-5 V, 1-5 V DC voltage output -10 to +12 V (+10V for Output 2) -10 to +11 V (Min. span: 1V) 0-10 V (-10 to +12 V for W5) 0-5 V, 1-5 V ±5V, ±10V (Specific range of) e.g. 1-5 V, 0-10 V -5 to +5 V (Min. span: 0.5V) e.g. 1-5 V, 0-10 V Minimum span 5mV Fixed (M6xWVS) 1V (5mV for W5VS) Out 2: Fixed Minimum span 5mV 1V (5mV for W5) Load resistance ≥5kΩ at 1-5 V ≥5kΩ at 1-5 V ≥500Ω at 1-5 V ≥500Ω at 1-5 V Load resistance ≥5kΩ at 1-5 V ≥5kΩ at 1-5 V ≥500Ω at 1-5 V Power input 24 Vdc or 100-240 Vac 24 Vdc 24 Vdc or 100-240 Vac Power input 24 Vdc or 100-240 Vac 24 Vdc 24 Vdc or 100-240 Vac Accuracy ±0.1% ±0.1% ±0.1% ±0.1% ±0.1% ±0.1% Accuracy ±0.4% ±0.2% Varies with the type and K, E, J:± 0.1% FS or 0.2ºC±0.2% Response time ≤0.5 sec. ≤180 µsec. ≤0.5 sec. ≤0.5 sec. ≤150 µsec. ≤0.5 sec. input / output range. T, N:± 0.2% FS or 0.2ºC (0-90%) 25 msec. optional 3.5 msec. optional (25 msec.25 msec./≤1 msec. For details, see the specification sheet. B, R, S: ±0.3% FS for M6xVS Current output) Response time (0-90%) ≤0.5 sec. standard; 25 msec. optional ≤0.5 sec. ≤0.5 sec. standard; 25 msec. optional Operating temperature -5 to +55ºC (23 to 131ºF) (Min. -20ºC or -44ºF for M6) Operating temperature -5 to +55ºC (23 to 131ºF) -20 to +55ºC (-4 to 131ºF) -5 to +55ºC (23 to 131ºF) Insulation resistance ≥100MΩ with 500 Vdc Insulation resistance ≥100MΩ with 500 Vdc Dielectric strength 2000 Vac @1 minute (input to output to power to ground) 2000 Vac @1 minute (DC powered M5) Dielectric strength 2000 Vac @1 minute (input to output to power to ground) 2000 Vac @1 minute (DC powered M5) 1500 Vac @1 minute (AC powered M5) 1500 Vac @1 minute (AC powered M5) CE marking Yes Yes Yes (24 Vdc powered) CE marking Yes Yes Yes (24 Vdc powered) Safety approval UL & C-UL nonincendive ------Safety approval UL & C-UL nonincendive ------

18 19 Frequency Transmitters Strain Gauge & Potentiometer Transmitters

Compact Plug-in Design Low-profile, Low Cost Type Field Configuration with Local Display, Compact Plug-in Design M2XPA2 Frequency input, PC programmable M5PA Frequency input, Single output Plug-in Type M2MS Potentiometer input, M2SP Frequency input, Single output W5PA Frequency input, Two isolated outputs MXLCF Strain gauge input Single output W2SP Frequency input, Two isolated outputs W2MS Potentiometer input, • 41 mm (1.6”) deep • ≤10 msec. response time Two isolated outputs • Converts the output from a pulse-type transducer into a DC signal • Converts the output from a pulse-type • Auto tare feature controlled by • 0.5V constant voltage excitation allows using • Two independent ranges can be specified with the signal splitter transducer into a DC signal PLC or DCS any resistance rating ofΩ 100to 10 Ωk M2AP Single frequency output • Optional 25 msec. response M2MS W2AP Dual frequency output time selectable W2MS • Two independent ranges can be specified with the signal splitter. • Provides a pulse rate output in proportion to DC input signal Ultra-high Speed Response, • Pulse integration application Remote Sensing, Plug-in Type Ultra-slim, Space-saving • Two independent ranges can be specified with the signal splitter M5PA W5PA LCF Strain gauge input M6SXM Potentiometer input, Tension-Clamp M2PP Single output pulse Isolator • Six-wire bridge can be used to M6NXM Potentiometer input, W2PP Dual output pulse Isolator compensate for lead resistance Standard Plug-in Design variations due to temperature changes. Screw terminal • Galvanically isolates pulse rate signals (For details, refer to Signal Conditioners Data Library at www.m-system.com) • ≤300 µsec. response (2 kHz, -3 dB) M6DXM Potentiometer input, • Switches pulse transducer types YPD Single output pulse isolator Euro terminal WYPD Dual output pulse isolator • PC programmable M6 Series M2XRP2 Rotary encoder speed transmitter JRP2 Rotary encoder speed transmitter Compact Plug-in Design Low-profile, Low Cost Type • Converts a two-phase forward and JRQ2 Rotary encoder position transmitter reverse rotation pulse signal with M2LCS Strain gauge input M5MS Potentiometer input, 90 degree phase difference into • Compatible with a bridge Single output a forward and reverse speed signal type strain gauge W5MS Potentiometer input, • Scaling factor adjustable • Optional 25 msec. response Two isolated outputs time selectable • 41 mm (1.6”) deep M2PRU Pulse Scaler • Optional 25 msec. • Converts pulse rate into convenient response time selectable engineering unit for display • Two independent ranges can be on a totalizing counter or meter specified with the signal splitter M5MS W5MS • Scaling factor adjustable M2 Series W2 Series YPD JRQ2 SPECIFICATIONS Series MX / M Series M2 / W2 Series M6 Series M5 / W5 Series SPECIFICATIONS Single output model MXLCF LCF M2LCS M2MS M6xXM M5MS Series M2 / W2 Series Dual output model W2MS W5MS Single output modelM2XPA2 M2SP M2AP M2PP M2PRU Input 1.0mV/V, 3.0mV/V,Specific rating Specific rating 100Ω min. 100Ω min. 100Ω min. Dual output model W2SP W2AP W2PP 10.0mV/V, 30.0mV/Vup to 20 mV/V up to 20 mV/V 10kΩ max. 5kΩ max. 10kΩ max. InputUser-calibrated Dry contact 0-300 V, e.g. 1-5 V Open collector Open collector Excitation 0.1-12 V, 120 mA 2-10V, 120 mA 2-10V, 35 mA ------(Open collector/ Voltage pulse Minimum span 1V Mechanical contact Mechanical contact DC current output Field-selectable: 0-20 mA 0-20 mA 0-20 mA 0-20 mA Mechanical contact/ Min. 50 Hz DC current with resistor, Voltage pulse Voltage pulse (Specific range of) 0-20 mA e.g. 4-20 mA e.g. 4-20 mA e.g. 4-20 mA Voltage pulse/RS-422/ Max. 10 kHz e.g. 4-20 mA Two-wire current Two-wire current) Minimum span ---- 1 mA 1 mA 1 mA 1 mA Load resistance ≤600Ω at 4-20 mA ≤750Ω at 4-20 mA ≤750Ω at 4-20 mA ≤550Ω at 4-20 mA ≤550Ω at 4-20 mA Sensor excitationUser-calibrated 12 Vdc @30mA ---- 12 Vdc @30mA 12 or 24 Vdc @30mA Load resistance, Out 2 ------≤350Ω at 4-20 mA ---- ≤550Ω at 4-20 mA 4, 8 or 12 Vdc @5mA DC voltage output Field-selectable: -10 to +12 V -10 to +12 V (+10 V for Output 2) -10 to +11 V 0-10 V (-10 to OutputUser-calibrated DC current: 0-20 mA Open collector (1 kHz) Open collector Open collector (Specific range of) ±1V, ±10V e.g. 1-5 V, 0-10 V e.g. 1-5 V, 0-10 V (Min. span: 1V) +12 V for W5) DC current: 0-20mA e.g. 4-20 mA / 750Ω Voltage pulse (1 kHz) Voltage pulse Voltage pulse e.g. 1-5 V, 0-10 V DC voltage: Minimum span 1mA Mercury relay (30 Hz) Mercury relay (M2PP) AC/DC switch -5 to +5 V (Min. span: 0.5V) -2.5 to +2.5V / DC voltage: 0-12 V Dry contact AC/DC Minimum span ---- 5 mV 5 mV 1V (5mV for W5) -10 to +10V (10 V for Output 2) switch (W2PP) Load resistance ≥1kΩ, ≥10kΩ≥5kΩ at 1-5 V ≥5kΩ at 1-5 V ≥5kΩ at 1-5 V ≥500Ω at 1-5 V ≥ Ω e.g. 1-5 V / 5k Power input 24 Vdc, 110 Vdc 100, 110, 120 Vac 24 Vdc or 100-240 Vac 24 Vdc 24 Vdc or Minimum span 5mV or 100-240 Vac 200, 220, 240 Vac 100-240 Vac Power input 24 Vdc or 100-240 Vac Accuracy ±0.2% ±0.1% ±0.1% * ±0.1% ± ± Accuracy ---- 0.1% 0.1% ------Response time (0-90%) ≤10 msec. ≤300 µsec. ≤0.5 sec.; 25 msec. optional ≤1 sec. ≤0.5 sec.; 25 msec. optional ≤ ≥ Response time (0-90%) ---- 0.5 sec. at 500 Hz Approx. 3 sec. ------Operating temperature -5 to +55ºC (23 to 131ºF) (Max. 60ºC or 140ºF for LCF; Min. -20ºC or -4ºF for M6) ° ° Operating temperature -5 to +55 C (23 to 131 F) Insulation resistance ≥100MΩ with 500 Vdc ≥ Ω Insulation resistance 100M with 500 Vdc Dielectric strength 2000 Vac @1 minute (input to output to power to ground) 2000 Vac @1 min. (DC) Dielectric strength 2000 Vac @1 minute (input to output to power to ground) 1500 Vac @1 min. (AC) CE marking Yes (except W2PP) CE marking Yes Yes Yes Yes (24 Vdc powered) Safety approval UL & C-UL nonincendive (UL/24 Vdc powered only for M2PP; except W2PP) Safety approval ---- UL & C-UL nonincendive ------*Varies with the type and input / output range. For details, see the specification sheet. 20 21 Frequency Transmitters Strain Gauge & Potentiometer Transmitters

Compact Plug-in Design Low-profile, Low Cost Type Field Configuration with Local Display, Compact Plug-in Design M2XPA2 Frequency input, PC programmable M5PA Frequency input, Single output Plug-in Type M2MS Potentiometer input, M2SP Frequency input, Single output W5PA Frequency input, Two isolated outputs MXLCF Strain gauge input Single output W2SP Frequency input, Two isolated outputs W2MS Potentiometer input, • 41 mm (1.6”) deep • ≤10 msec. response time Two isolated outputs • Converts the output from a pulse-type transducer into a DC signal • Converts the output from a pulse-type • Auto tare feature controlled by • 0.5V constant voltage excitation allows using • Two independent ranges can be specified with the signal splitter transducer into a DC signal PLC or DCS any resistance rating ofΩ 100to 10 Ωk M2AP Single frequency output • Optional 25 msec. response M2MS W2AP Dual frequency output time selectable W2MS • Two independent ranges can be specified with the signal splitter. • Provides a pulse rate output in proportion to DC input signal Ultra-high Speed Response, • Pulse integration application Remote Sensing, Plug-in Type Ultra-slim, Space-saving • Two independent ranges can be specified with the signal splitter M5PA W5PA LCF Strain gauge input M6SXM Potentiometer input, Tension-Clamp M2PP Single output pulse Isolator • Six-wire bridge can be used to M6NXM Potentiometer input, W2PP Dual output pulse Isolator compensate for lead resistance Standard Plug-in Design variations due to temperature changes. Screw terminal • Galvanically isolates pulse rate signals (For details, refer to Signal Conditioners Data Library at www.m-system.com) • ≤300 µsec. response (2 kHz, -3 dB) M6DXM Potentiometer input, • Switches pulse transducer types YPD Single output pulse isolator Euro terminal WYPD Dual output pulse isolator • PC programmable M6 Series M2XRP2 Rotary encoder speed transmitter JRP2 Rotary encoder speed transmitter Compact Plug-in Design Low-profile, Low Cost Type • Converts a two-phase forward and JRQ2 Rotary encoder position transmitter reverse rotation pulse signal with M2LCS Strain gauge input M5MS Potentiometer input, 90 degree phase difference into • Compatible with a bridge Single output a forward and reverse speed signal type strain gauge W5MS Potentiometer input, • Scaling factor adjustable • Optional 25 msec. response Two isolated outputs time selectable • 41 mm (1.6”) deep M2PRU Pulse Scaler • Optional 25 msec. • Converts pulse rate into convenient response time selectable engineering unit for display • Two independent ranges can be on a totalizing counter or meter specified with the signal splitter M5MS W5MS • Scaling factor adjustable M2 Series W2 Series YPD JRQ2 SPECIFICATIONS Series MX / M Series M2 / W2 Series M6 Series M5 / W5 Series SPECIFICATIONS Single output model MXLCF LCF M2LCS M2MS M6xXM M5MS Series M2 / W2 Series Dual output model W2MS W5MS Single output modelM2XPA2 M2SP M2AP M2PP M2PRU Input 1.0mV/V, 3.0mV/V,Specific rating Specific rating 100Ω min. 100Ω min. 100Ω min. Dual output model W2SP W2AP W2PP 10.0mV/V, 30.0mV/Vup to 20 mV/V up to 20 mV/V 10kΩ max. 5kΩ max. 10kΩ max. InputUser-calibrated Dry contact 0-300 V, e.g. 1-5 V Open collector Open collector Excitation 0.1-12 V, 120 mA 2-10V, 120 mA 2-10V, 35 mA ------(Open collector/ Voltage pulse Minimum span 1V Mechanical contact Mechanical contact DC current output Field-selectable: 0-20 mA 0-20 mA 0-20 mA 0-20 mA Mechanical contact/ Min. 50 Hz DC current with resistor, Voltage pulse Voltage pulse (Specific range of) 0-20 mA e.g. 4-20 mA e.g. 4-20 mA e.g. 4-20 mA Voltage pulse/RS-422/ Max. 10 kHz e.g. 4-20 mA Two-wire current Two-wire current) Minimum span ---- 1 mA 1 mA 1 mA 1 mA Load resistance ≤600Ω at 4-20 mA ≤750Ω at 4-20 mA ≤750Ω at 4-20 mA ≤550Ω at 4-20 mA ≤550Ω at 4-20 mA Sensor excitationUser-calibrated 12 Vdc @30mA ---- 12 Vdc @30mA 12 or 24 Vdc @30mA Load resistance, Out 2 ------≤350Ω at 4-20 mA ---- ≤550Ω at 4-20 mA 4, 8 or 12 Vdc @5mA DC voltage output Field-selectable: -10 to +12 V -10 to +12 V (+10 V for Output 2) -10 to +11 V 0-10 V (-10 to OutputUser-calibrated DC current: 0-20 mA Open collector (1 kHz) Open collector Open collector (Specific range of) ±1V, ±10V e.g. 1-5 V, 0-10 V e.g. 1-5 V, 0-10 V (Min. span: 1V) +12 V for W5) DC current: 0-20mA e.g. 4-20 mA / 750Ω Voltage pulse (1 kHz) Voltage pulse Voltage pulse e.g. 1-5 V, 0-10 V DC voltage: Minimum span 1mA Mercury relay (30 Hz) Mercury relay (M2PP) AC/DC switch -5 to +5 V (Min. span: 0.5V) -2.5 to +2.5V / DC voltage: 0-12 V Dry contact AC/DC Minimum span ---- 5 mV 5 mV 1V (5mV for W5) -10 to +10V (10 V for Output 2) switch (W2PP) Load resistance ≥1kΩ, ≥10kΩ≥5kΩ at 1-5 V ≥5kΩ at 1-5 V ≥5kΩ at 1-5 V ≥500Ω at 1-5 V ≥ Ω e.g. 1-5 V / 5k Power input 24 Vdc, 110 Vdc 100, 110, 120 Vac 24 Vdc or 100-240 Vac 24 Vdc 24 Vdc or Minimum span 5mV or 100-240 Vac 200, 220, 240 Vac 100-240 Vac Power input 24 Vdc or 100-240 Vac Accuracy ±0.2% ±0.1% ±0.1% * ±0.1% ± ± Accuracy ---- 0.1% 0.1% ------Response time (0-90%) ≤10 msec. ≤300 µsec. ≤0.5 sec.; 25 msec. optional ≤1 sec. ≤0.5 sec.; 25 msec. optional ≤ ≥ Response time (0-90%) ---- 0.5 sec. at 500 Hz Approx. 3 sec. ------Operating temperature -5 to +55ºC (23 to 131ºF) (Max. 60ºC or 140ºF for LCF; Min. -20ºC or -4ºF for M6) ° ° Operating temperature -5 to +55 C (23 to 131 F) Insulation resistance ≥100MΩ with 500 Vdc ≥ Ω Insulation resistance 100M with 500 Vdc Dielectric strength 2000 Vac @1 minute (input to output to power to ground) 2000 Vac @1 min. (DC) Dielectric strength 2000 Vac @1 minute (input to output to power to ground) 1500 Vac @1 min. (AC) CE marking Yes (except W2PP) CE marking Yes Yes Yes Yes (24 Vdc powered) Safety approval UL & C-UL nonincendive (UL/24 Vdc powered only for M2PP; except W2PP) Safety approval ---- UL & C-UL nonincendive ------*Varies with the type and input / output range. For details, see the specification sheet. 20 21 AC Input Transmitters Pneumatic Transducers

Compact Plug-in Design Low-profile, Low Cost Type Compact Plug-in Design M2PV Pneumatic input, Single output W2PV Pneumatic input, Two isolated outputs • Converts a standard pneumatic signal into a DC signal. • Two independent ranges can be specified with the signal splitter.

M5PT PT (VT) input M5CT CT input M2AC M2PV W2PV W2AC • 41 mm (1.6”) deep • True RMS sensing M2AC AC input, Single output W2AC AC input, Two isolated outputs • True RMS sensing Two-wire Pneumatic Transducer • Two independent ranges can be specified with the signal splitter. BPV Pressure to current • Monitor terminal (4-20 mA) M2TG Tachogenerator input, Single output W2TG Tachogenerator input, Two isolated outputs • Tachometer input • Two independent ranges can be specified with the signal splitter.

Two-wire Self-powered Pneumatic Transducer HVPN Current to pressure M2CE • Semiconductor pressure sensor in the feedback circuit W2CE • No mounting position effect M2PE/M2PA PT (VT) input, Single output W2PE/W2PA PT (VT) input, Two isolated outputs M2CE/M2CA CT input, Single output W2CE/W2CA CT input, Two isolated outputs • True RMS or average sensing • Two independent ranges can be specified with the signal splitter.

SPECIFICATIONS Series M2 / W2 Series M5 Series Single output model M2AC M2TG M2PE / M2PA M2CE / M2CA M5PT M5CT SPECIFICATIONS Dual output model W2AC W2TG W2PE / W2PA W2CE / W2CA Series M2 / W2 Series B-UNIT Series H-UNIT Series Input Specific range of Specific range of 0-110 Vac 0-1 Aac 0-110, 0-220 Vac 0-1 Aac Single output model M2PV BPV HVPN 0-250 V or 0-1 A 0-250 V 0-150 Vac 0-5 Aac 0-150 Vac 0-5 Aac Dual output model W2PV DC current output 0-20 mA; Minimum span 1mA; e.g. 4-20 mA 0-20 mA; Min. 1mA span Input 19.6-98.1 kPa (0.2-1.0 kgf/cm2) 19.6-98.1 kPa (0.2-1.0 kgf/cm2) 4-20 mA (Specific range of) e.g. 4-20 mA 20-100 kPa (0.2-1.0 bar) 20-100 kPa (0.2-1.0 bar) Load resistance ≤750Ω at 4-20 mA (≤350Ω at 4-20 mA for Output 2) ≤550Ω at 4-20 mA 20.7-103.4 kPa (3-15 psig) 20.7-103.4 kPa (3-15 psig) DC voltage output -10 to +12 V (+10V for Output 2) 0-12 V (10V for Output 2) 0-10 V; Min. 1V span Output Specific range of 0-20 mA; Minimum span 1mA 4-20 mA 19.6-98.1 kPa (0.2-1.0 kgf/cm2) (Specific range of) e.g. 1-5 V, 0-10 V e.g. 1-5 V, 0-10 V e.g. 1-5 V, 0-10 V e.g. 4-20 mA / ≤750Ω≤600Ω 20-100 kPa (0.2-1.0 bar) ≤ Ω Load resistance ≥5kΩ at 1-5 V ≥500Ω at 1-5 V ( 350 at 4-20 mA for Output 2) 20.7-103.4 kPa (3-15 psig) Power input 24 Vdc or 100-240 Vac 24 Vdc or 100-240 Vac Max. air capacity ------60 Nl/minute Accuracy ±0.4% ±0.4% ±0.4% ±0.3% ±0.3% Power input 24 Vdc or 100-240 Vac 15-28 Vdc Not required ± ± ± Response time (0-90%) ≤0.7 sec. ≤0.7 sec. ≤0.5 sec. ≤0.5 sec. ≤0.5 sec. Accuracy 0.3% 0.3% 0.3% ≤ ≤ ≤ Operating temperature -5 to +55ºC (23 to 131ºF) Response time (0-90%) 0.5 sec. 0.5 sec. 3 sec. Insulation resistance ≥100MΩ with 500 Vdc Operating temperature -5 to +55ºC (23 to 131ºF) -10 to +60ºC (14 to 140ºF) -5 to +55ºC (23 to 131ºF) ≥ Ω Dielectric strength 2000 Vac @1 minute (input to output to power to ground) 2000 Vac @1 minute (DC powered) Insulation resistance 100M with 500 Vdc ------1500 Vac @1 minute (AC powered) Dielectric strength 2000 Vac @1 minute (output to power to ground) ---- 1500 Vac @1 minute (input to housing) CE marking Yes ---- Yes (24 Vdc powered) CE marking Yes Safety approval UL & C-UL nonincendive ---- Safety approval UL & C-UL nonincendive ------

22 23 AC Input Transmitters Pneumatic Transducers

Compact Plug-in Design Low-profile, Low Cost Type Compact Plug-in Design M2PV Pneumatic input, Single output W2PV Pneumatic input, Two isolated outputs • Converts a standard pneumatic signal into a DC signal. • Two independent ranges can be specified with the signal splitter.

M5PT PT (VT) input M5CT CT input M2AC M2PV W2PV W2AC • 41 mm (1.6”) deep • True RMS sensing M2AC AC input, Single output W2AC AC input, Two isolated outputs • True RMS sensing Two-wire Pneumatic Transducer • Two independent ranges can be specified with the signal splitter. BPV Pressure to current • Monitor terminal (4-20 mA) M2TG Tachogenerator input, Single output W2TG Tachogenerator input, Two isolated outputs • Tachometer input • Two independent ranges can be specified with the signal splitter.

Two-wire Self-powered Pneumatic Transducer HVPN Current to pressure M2CE • Semiconductor pressure sensor in the feedback circuit W2CE • No mounting position effect M2PE/M2PA PT (VT) input, Single output W2PE/W2PA PT (VT) input, Two isolated outputs M2CE/M2CA CT input, Single output W2CE/W2CA CT input, Two isolated outputs • True RMS or average sensing • Two independent ranges can be specified with the signal splitter.

SPECIFICATIONS Series M2 / W2 Series M5 Series Single output model M2AC M2TG M2PE / M2PA M2CE / M2CA M5PT M5CT SPECIFICATIONS Dual output model W2AC W2TG W2PE / W2PA W2CE / W2CA Series M2 / W2 Series B-UNIT Series H-UNIT Series Input Specific range of Specific range of 0-110 Vac 0-1 Aac 0-110, 0-220 Vac 0-1 Aac Single output model M2PV BPV HVPN 0-250 V or 0-1 A 0-250 V 0-150 Vac 0-5 Aac 0-150 Vac 0-5 Aac Dual output model W2PV DC current output 0-20 mA; Minimum span 1mA; e.g. 4-20 mA 0-20 mA; Min. 1mA span Input 19.6-98.1 kPa (0.2-1.0 kgf/cm2) 19.6-98.1 kPa (0.2-1.0 kgf/cm2) 4-20 mA (Specific range of) e.g. 4-20 mA 20-100 kPa (0.2-1.0 bar) 20-100 kPa (0.2-1.0 bar) Load resistance ≤750Ω at 4-20 mA (≤350Ω at 4-20 mA for Output 2) ≤550Ω at 4-20 mA 20.7-103.4 kPa (3-15 psig) 20.7-103.4 kPa (3-15 psig) DC voltage output -10 to +12 V (+10V for Output 2) 0-12 V (10V for Output 2) 0-10 V; Min. 1V span Output Specific range of 0-20 mA; Minimum span 1mA 4-20 mA 19.6-98.1 kPa (0.2-1.0 kgf/cm2) (Specific range of) e.g. 1-5 V, 0-10 V e.g. 1-5 V, 0-10 V e.g. 1-5 V, 0-10 V e.g. 4-20 mA / ≤750Ω≤600Ω 20-100 kPa (0.2-1.0 bar) ≤ Ω Load resistance ≥5kΩ at 1-5 V ≥500Ω at 1-5 V ( 350 at 4-20 mA for Output 2) 20.7-103.4 kPa (3-15 psig) Power input 24 Vdc or 100-240 Vac 24 Vdc or 100-240 Vac Max. air capacity ------60 Nl/minute Accuracy ±0.4% ±0.4% ±0.4% ±0.3% ±0.3% Power input 24 Vdc or 100-240 Vac 15-28 Vdc Not required ± ± ± Response time (0-90%) ≤0.7 sec. ≤0.7 sec. ≤0.5 sec. ≤0.5 sec. ≤0.5 sec. Accuracy 0.3% 0.3% 0.3% ≤ ≤ ≤ Operating temperature -5 to +55ºC (23 to 131ºF) Response time (0-90%) 0.5 sec. 0.5 sec. 3 sec. Insulation resistance ≥100MΩ with 500 Vdc Operating temperature -5 to +55ºC (23 to 131ºF) -10 to +60ºC (14 to 140ºF) -5 to +55ºC (23 to 131ºF) ≥ Ω Dielectric strength 2000 Vac @1 minute (input to output to power to ground) 2000 Vac @1 minute (DC powered) Insulation resistance 100M with 500 Vdc ------1500 Vac @1 minute (AC powered) Dielectric strength 2000 Vac @1 minute (output to power to ground) ---- 1500 Vac @1 minute (input to housing) CE marking Yes ---- Yes (24 Vdc powered) CE marking Yes Safety approval UL & C-UL nonincendive ---- Safety approval UL & C-UL nonincendive ------

22 23 B3 Series Current Loop Supplies & DC Power Supplies DIP-Switch Configurable Two-wire Transmitters

Compact Plug-in Design Low-profile, Low Cost Type Input type and range selectable with the internal DIP switches and fine calibration using the front potentiometers. Wide supply voltage range 12-45 Vdc Eliminates noise and prevents ground loops with 1500 Vac isolation between input and output

M2 Series W2 Series M5DY W5DY 2000 Vac isolation

M2DYS Single output M5DY Single output M-System’s B3 Series are DIN rail mounted, input configurable W2DYS Two isolated outputs W5DY Two isolated outputs two-wire transmitters with 1500 Vac isolation between input and • Shortcircuit protection • 41 mm (1.6”) deep output. • Monitor terminal (1-5 V) • Shortcircuit protection The input type & range are easily programmable with internal • Two independent ranges can be specified with the signal • Monitor terminal (1-5 V) DIP switches and front potentiometers, not needing any special splitter. • Two independent ranges can be specified with the signal computer knowledge to program. splitter. M2DNY Square root extractor, Single output For example, after setting the internal SW1 and SW2 for W2DNY Square root extractor, Two isolated outputs DC Power Supply selecting an overall range, gain and offset, using a DC input (For details, refer to Signal Conditioners Data Library at www.m-system.com) • Shortcircuit protection simulator as a reference, the B3FV could be adjusted to 0 to 10 • Low-end cutout 4-8 % MDC5 / MDC6 / MDC7 V range by simply applying desired minimum and maximum • Monitor terminal (4-20 mA) • Accepts 100-240 Vac and provides regulated 24 Vdc output input levels and turning the respective front potentiometer. (60W / 120W / 240W) • Maintenance forecast monitor function Typical applications include eliminating ground loops in tem- Ultra-slim, Space-saving perature, flow and level measurement applications and provid- M6SDY Tension-Clamp ing an isolated interface to data acquisition and control systems. M6NDY Screw terminal M6DDY Euro terminal For the most basic isolation applications, the Model B3VS/2 dual channel isolator is an economical solution. The B3VS/2 • Shortcircuit protection houses two transmitters in the series’ standard enclosure, accepting and providing independently isolated 4-20 mA MODEL FUNCTION signals. B3HU Universal temperature input, HART B3PU Universal temperature input, PROFIBUS-PA SPECIFICATIONS Series M2 / W2 Series M6 Series M5 / W5 Series B3FV DC mV, V, mA input Single output model M2DYS M2DNY M6xDY M5DY B3FT Thermocouple input Dual output model W2DYS W2DNY W5DY B3FR RTD input Input 4-20 mA 4-20 mA 4-20 mA B3FP Frequency input Supply output 24-28 Vdc with no load 24-28 Vdc with no load 24-28 Vdc with no load B3VS/1 Single-channel 4-20 mA isolator Current rating 22mA 22mA 22mA DC current output 0-20 mA; Min. 1mA span 4-20 mA 0-20 mA; Min. 1mA span B3VS/2 Dual-channel 4-20 mA isolator (Specific range of) e.g. 4-20 mA e.g. 4-20 mA SPECIFICATIONS Load resistance ≤750Ω at 4-20 mA ---- ≤550Ω at 4-20 mA Input type DC mV, V, mA Thermocouple RTD Frequency Load resistance, Out 2 ≤350Ω at 4-20 mA ------Model No. B3FV B3FT B3FR B3FP DC voltage output 0-12 V (10 V for Output 2); Min. 5mV span0-10V, 0-5V, 1-5 V 0-10 V; Min. 1V span Selectable input -30 to +30 mA K, E, J, T, R, N Pt 100, Ni 120 Open collector, Voltage pulse (Specific range of) e.g. 1-5 V, 0-10 V e.g. 1-5 V, 0-10 V ±100V Cu 10 @25ºC Two-wire current, Max. 100 kHz Load resistance ≥5kΩ at 1-5 V ≥5kΩ at 1-5 V ≥500Ω at 1-5 V Output 4-20 mA (600Ω at 24V) Power input 24 Vdc or 100-240 Vac 24 Vdc 24 Vdc or 100-240 Vac Supply voltage 12-45 Vdc Accuracy ±0.1% ±0.2% ±0.1% ±0.1% Accuracy ±0.1% ±0.2% (K/J), ±0.3% (T/E/N) ±0.2% (±0.3% for Ni 120) ±0.1% typical ± Response time (0-90%) ≤0.5 sec. ≤0.1 msec. ≤0.5 sec. standard; 25 msec. optional 0.4% (R) typical ≤ ≤ ≤ ≤ Operating temperature -5 to +55ºC (23 to 131ºF) -20 to +55ºC (-4 to 131ºF) -5 to +55ºC (23 to 131ºF) Response time (0-90%) 0.5 sec. 0.5 sec. 0.5 sec. 0.5 sec. + pulse cycle Insulation resistance ≥100MΩ with 500 Vdc ≥100MΩ with 500 Vdc ≥100MΩ with 500 Vdc Operating temperature -40 to +85ºC (-40 to +185ºF) ≥ Ω Dielectric strength 2000 Vac @1 minute 2000V AC @1 minute 2000 Vac @1 minute (DC powered) Insulation resistance 100M with 500 Vdc (input to output to power to ground) (input or output to power to ground) 1500 Vac @1 minute (AC powered) Dielectric strength 2000 Vac @1 minute (input to output to ground) CE marking Yes Yes Yes (24 Vdc powered) CE marking Yes Safety approval UL & C-UL nonincendive ------Safety approval UL & C-UL

24 25 B3 Series Current Loop Supplies & DC Power Supplies DIP-Switch Configurable Two-wire Transmitters

Compact Plug-in Design Low-profile, Low Cost Type Input type and range selectable with the internal DIP switches and fine calibration using the front potentiometers. Wide supply voltage range 12-45 Vdc Eliminates noise and prevents ground loops with 1500 Vac isolation between input and output

M2 Series W2 Series M5DY W5DY 2000 Vac isolation

M2DYS Single output M5DY Single output M-System’s B3 Series are DIN rail mounted, input configurable W2DYS Two isolated outputs W5DY Two isolated outputs two-wire transmitters with 1500 Vac isolation between input and • Shortcircuit protection • 41 mm (1.6”) deep output. • Monitor terminal (1-5 V) • Shortcircuit protection The input type & range are easily programmable with internal • Two independent ranges can be specified with the signal • Monitor terminal (1-5 V) DIP switches and front potentiometers, not needing any special splitter. • Two independent ranges can be specified with the signal computer knowledge to program. splitter. M2DNY Square root extractor, Single output For example, after setting the internal SW1 and SW2 for W2DNY Square root extractor, Two isolated outputs DC Power Supply selecting an overall range, gain and offset, using a DC input (For details, refer to Signal Conditioners Data Library at www.m-system.com) • Shortcircuit protection simulator as a reference, the B3FV could be adjusted to 0 to 10 • Low-end cutout 4-8 % MDC5 / MDC6 / MDC7 V range by simply applying desired minimum and maximum • Monitor terminal (4-20 mA) • Accepts 100-240 Vac and provides regulated 24 Vdc output input levels and turning the respective front potentiometer. (60W / 120W / 240W) • Maintenance forecast monitor function Typical applications include eliminating ground loops in tem- Ultra-slim, Space-saving perature, flow and level measurement applications and provid- M6SDY Tension-Clamp ing an isolated interface to data acquisition and control systems. M6NDY Screw terminal M6DDY Euro terminal For the most basic isolation applications, the Model B3VS/2 dual channel isolator is an economical solution. The B3VS/2 • Shortcircuit protection houses two transmitters in the series’ standard enclosure, accepting and providing independently isolated 4-20 mA MODEL FUNCTION signals. B3HU Universal temperature input, HART B3PU Universal temperature input, PROFIBUS-PA SPECIFICATIONS Series M2 / W2 Series M6 Series M5 / W5 Series B3FV DC mV, V, mA input Single output model M2DYS M2DNY M6xDY M5DY B3FT Thermocouple input Dual output model W2DYS W2DNY W5DY B3FR RTD input Input 4-20 mA 4-20 mA 4-20 mA B3FP Frequency input Supply output 24-28 Vdc with no load 24-28 Vdc with no load 24-28 Vdc with no load B3VS/1 Single-channel 4-20 mA isolator Current rating 22mA 22mA 22mA DC current output 0-20 mA; Min. 1mA span 4-20 mA 0-20 mA; Min. 1mA span B3VS/2 Dual-channel 4-20 mA isolator (Specific range of) e.g. 4-20 mA e.g. 4-20 mA SPECIFICATIONS Load resistance ≤750Ω at 4-20 mA ---- ≤550Ω at 4-20 mA Input type DC mV, V, mA Thermocouple RTD Frequency Load resistance, Out 2 ≤350Ω at 4-20 mA ------Model No. B3FV B3FT B3FR B3FP DC voltage output 0-12 V (10 V for Output 2); Min. 5mV span0-10V, 0-5V, 1-5 V 0-10 V; Min. 1V span Selectable input -30 to +30 mA K, E, J, T, R, N Pt 100, Ni 120 Open collector, Voltage pulse (Specific range of) e.g. 1-5 V, 0-10 V e.g. 1-5 V, 0-10 V ±100V Cu 10 @25ºC Two-wire current, Max. 100 kHz Load resistance ≥5kΩ at 1-5 V ≥5kΩ at 1-5 V ≥500Ω at 1-5 V Output 4-20 mA (600Ω at 24V) Power input 24 Vdc or 100-240 Vac 24 Vdc 24 Vdc or 100-240 Vac Supply voltage 12-45 Vdc Accuracy ±0.1% ±0.2% ±0.1% ±0.1% Accuracy ±0.1% ±0.2% (K/J), ±0.3% (T/E/N) ±0.2% (±0.3% for Ni 120) ±0.1% typical ± Response time (0-90%) ≤0.5 sec. ≤0.1 msec. ≤0.5 sec. standard; 25 msec. optional 0.4% (R) typical ≤ ≤ ≤ ≤ Operating temperature -5 to +55ºC (23 to 131ºF) -20 to +55ºC (-4 to 131ºF) -5 to +55ºC (23 to 131ºF) Response time (0-90%) 0.5 sec. 0.5 sec. 0.5 sec. 0.5 sec. + pulse cycle Insulation resistance ≥100MΩ with 500 Vdc ≥100MΩ with 500 Vdc ≥100MΩ with 500 Vdc Operating temperature -40 to +85ºC (-40 to +185ºF) ≥ Ω Dielectric strength 2000 Vac @1 minute 2000V AC @1 minute 2000 Vac @1 minute (DC powered) Insulation resistance 100M with 500 Vdc (input to output to power to ground) (input or output to power to ground) 1500 Vac @1 minute (AC powered) Dielectric strength 2000 Vac @1 minute (input to output to ground) CE marking Yes Yes Yes (24 Vdc powered) CE marking Yes Safety approval UL & C-UL nonincendive ------Safety approval UL & C-UL

24 25 Two-wire Fixed Range Transmitters Two-wire Universal Temperature Transmitters

Compact Plug-in Design Thin-profile Type Field Mount Type M2SN-1 Input loop powered (self-powered), One channel B3VS/1 Output loop powered, B6U-B HART, Intrinsically safe / explosion-proof - flameproof / M2SN-2 Input loop powered (self-powered), Two channels One channel nonincendive • No external power source required B3VS/2 Output loop powered, B6U HART, Intrinsically safe / nonincendive • 4-20 mA or 10-50 mA input Two channels • 18 mm (.71”) wide Plug-in two-line LCD display • Specific input range of ±100V; current input with HART programmable the incorporated resistor B3 Series AMS software version 6.0 or higher Stainless steel enclosure optional Ultra-slim, Space-saving M6SSN -1, -2 Tension-Clamp ATEX Zone 0 approvals Æ M2SN-1 M2SN-2 M6NSN -1, -2 Screw terminal M6DSN -1, -2 Euro terminal FM Class I, II, III, Division 1 approvals Low-profile, Low Cost Type • Inputloop powerd (self-powerd) M-System’s Models B6U and B6U-B accept a wide variety of inputs including thermocouples and RTDs as well as mV, resistance and B5SN Input loop powered (self-powered) isolator potentiometer sensor types. This universal two-wire transmitter reduces component costs while meeting the requirements of hazardous Isolator • One channel, Two channels applications. They provide signal isolation to output a proportional 4-20 mA signal. B5VS Output loop powered Isolator Both models have the HART capability which allows users a flexibility to program the modules either via hand-held communicator or via PC. B5TS Thermocouple input M6 Series Input sensor type, temperature range and other items including HART properties are programmable. Additionally, users’ own temperature B5RS RTD input SPECIFICATIONS calibration tables can be used. This feature makes the B6U and B6U-B the most universal temperature transmitters. B5MS Potentiometer input Configuration Input loop powered (Self-powered) Optional highly legible LCD display indicates input signal in engineering unit and the transmitter status. The module is also used to configure • 41 mm (1.6”) deep Series M2 Series B5 Series M6 Series the transmitter and can be removed when not used. • Linearization, burnout protection, Model No. M2SN B5SN M6xSN cold junction compensation The B6U designed for intrinsic safety and the B6U-B including the explosion-proof (flameproof) enclosure (NEMA 4X, IP65) arest mo suitable for Input 4-20 mA, 10-50 mA 4-20 mA 0-20 mA (4-20 mA) use in an explosive atmosphere in chemical and petrochemical industries. A pipe mounting bracket is optional for the B6U-B easyfor installation. (T/C input) standard Output 4-20 mA, 1-5 V 4-20 mA 0-20 mA (4-20 mA) • Optional 25 msec. response time selectable Load resistance 50 to 350Ω with 4-20 mA input/output 0 to 600Ω Accuracy ±0.1% DIN Rail Mount, Thin-profile Type Response time (0-90%) 15 msec., current output 20 msec. B3HU HART ≤0.5 sec., voltage output B3PU PROFIBUS-PA Operating temperature -5 to +55ºC (23 to +131ºF) (Min. -20ºC or -4ºF for M6) Insulation resistance ≥100MΩ with 500 Vdc • 18 mm (.71”) wide Dielectric strength 500 Vac @1 minute (input to output) 1500 Vac @1 minute • AMS software version 6.0 or higher (input to output) • SIMATIC PDM CE marking Yes Yes Yes • ATEX Zone 0 approvals (B3HU) B5 Series Safety approval UL nonincendive ------

SPECIFICATIONS Æ Configuration Output loop powered Series B3 Series B5 Series Model No. B3VS B5VS B5TS B5RS B5MS SPECIFICATIONS Input Specific range of -100 to +100 V Specific range of -30 to +30 V K, E, J, T, B, Pt100, Pt50, 100Ω min. Series B6 Series B3 Series Min. 1V span Min. 100mV span R, S, N Ni508.4 10kΩ max. 4-20 mA, 0-10 mA, etc. 4-20 mA, 0-10 mA, etc. Model No. B6U B6U-B B3HU B3PU Output 4-20 mA (600Ω at 24V) Selectable input K, E, J, T, B, R, S, C, N, U, L, P, Pt 100 - Pt 1000, Ni 100, Ni 120, Ni 508.4, Ni-Fe 604, Cu 10 @25ºC 0 to 4000Ω, -50 to +1000 mV Supply voltage 12-45 Vdc 12-28 Vdc Output 4-20 mA (500Ω at 24V) PROFIBUS-PA Accuracy ±0.1% ±0.1% ±0.1% (K/E/J) ±0.2% ±0.1% ±0.2% (T/N) Supply voltage 12-42 Vdc (up to 28V approved) 9-30 Vdc (up to 24V approved) ±0.3% (B/R/S) Accuracy Depends upon the I/O types and ranges. Refer to the data sheet for the respective model for detail. Response time (0-90%) ≤0.1 sec. ≤0.5 sec., 25 msec. optional Response time (0-90%) ≤2 sec. Operating temperature -40 to +85ºC (-40 to +185ºF) -40 to +80ºC (-40 to +176ºF) Operating temperature -40 to +85ºC (-40 to +185ºF) Insulation resistance ≥100MΩ with 500 Vdc Insulation resistance ≥100MΩ with 500 Vdc Dielectric strength 2000 Vac @1 minute (input to output to ground) Dielectric strength 1500 Vac @1 minute (input to output) CE marking Yes CE marking EMC / ATEX EMC / ATEX EMC Safety approval UL & C-UL ---- Safety approval IS, nonincendive IS, EX, nonincendive IS ---- • Refer to data sheet of respective models for detailed specifications for use in classified locations.

26 27 Two-wire Fixed Range Transmitters Two-wire Universal Temperature Transmitters

Compact Plug-in Design Thin-profile Type Field Mount Type M2SN-1 Input loop powered (self-powered), One channel B3VS/1 Output loop powered, B6U-B HART, Intrinsically safe / explosion-proof - flameproof / M2SN-2 Input loop powered (self-powered), Two channels One channel nonincendive • No external power source required B3VS/2 Output loop powered, B6U HART, Intrinsically safe / nonincendive • 4-20 mA or 10-50 mA input Two channels • 18 mm (.71”) wide Plug-in two-line LCD display • Specific input range of ±100V; current input with HART programmable the incorporated resistor B3 Series AMS software version 6.0 or higher Stainless steel enclosure optional Ultra-slim, Space-saving M6SSN -1, -2 Tension-Clamp ATEX Zone 0 approvals Æ M2SN-1 M2SN-2 M6NSN -1, -2 Screw terminal M6DSN -1, -2 Euro terminal FM Class I, II, III, Division 1 approvals Low-profile, Low Cost Type • Inputloop powerd (self-powerd) M-System’s Models B6U and B6U-B accept a wide variety of inputs including thermocouples and RTDs as well as mV, resistance and B5SN Input loop powered (self-powered) isolator potentiometer sensor types. This universal two-wire transmitter reduces component costs while meeting the requirements of hazardous Isolator • One channel, Two channels applications. They provide signal isolation to output a proportional 4-20 mA signal. B5VS Output loop powered Isolator Both models have the HART capability which allows users a flexibility to program the modules either via hand-held communicator or via PC. B5TS Thermocouple input M6 Series Input sensor type, temperature range and other items including HART properties are programmable. Additionally, users’ own temperature B5RS RTD input SPECIFICATIONS calibration tables can be used. This feature makes the B6U and B6U-B the most universal temperature transmitters. B5MS Potentiometer input Configuration Input loop powered (Self-powered) Optional highly legible LCD display indicates input signal in engineering unit and the transmitter status. The module is also used to configure • 41 mm (1.6”) deep Series M2 Series B5 Series M6 Series the transmitter and can be removed when not used. • Linearization, burnout protection, Model No. M2SN B5SN M6xSN cold junction compensation The B6U designed for intrinsic safety and the B6U-B including the explosion-proof (flameproof) enclosure (NEMA 4X, IP65) arest mo suitable for Input 4-20 mA, 10-50 mA 4-20 mA 0-20 mA (4-20 mA) use in an explosive atmosphere in chemical and petrochemical industries. A pipe mounting bracket is optional for the B6U-B easyfor installation. (T/C input) standard Output 4-20 mA, 1-5 V 4-20 mA 0-20 mA (4-20 mA) • Optional 25 msec. response time selectable Load resistance 50 to 350Ω with 4-20 mA input/output 0 to 600Ω Accuracy ±0.1% DIN Rail Mount, Thin-profile Type Response time (0-90%) 15 msec., current output 20 msec. B3HU HART ≤0.5 sec., voltage output B3PU PROFIBUS-PA Operating temperature -5 to +55ºC (23 to +131ºF) (Min. -20ºC or -4ºF for M6) Insulation resistance ≥100MΩ with 500 Vdc • 18 mm (.71”) wide Dielectric strength 500 Vac @1 minute (input to output) 1500 Vac @1 minute • AMS software version 6.0 or higher (input to output) • SIMATIC PDM CE marking Yes Yes Yes • ATEX Zone 0 approvals (B3HU) B5 Series Safety approval UL nonincendive ------

SPECIFICATIONS Æ Configuration Output loop powered Series B3 Series B5 Series Model No. B3VS B5VS B5TS B5RS B5MS SPECIFICATIONS Input Specific range of -100 to +100 V Specific range of -30 to +30 V K, E, J, T, B, Pt100, Pt50, 100Ω min. Series B6 Series B3 Series Min. 1V span Min. 100mV span R, S, N Ni508.4 10kΩ max. 4-20 mA, 0-10 mA, etc. 4-20 mA, 0-10 mA, etc. Model No. B6U B6U-B B3HU B3PU Output 4-20 mA (600Ω at 24V) Selectable input K, E, J, T, B, R, S, C, N, U, L, P, Pt 100 - Pt 1000, Ni 100, Ni 120, Ni 508.4, Ni-Fe 604, Cu 10 @25ºC 0 to 4000Ω, -50 to +1000 mV Supply voltage 12-45 Vdc 12-28 Vdc Output 4-20 mA (500Ω at 24V) PROFIBUS-PA Accuracy ±0.1% ±0.1% ±0.1% (K/E/J) ±0.2% ±0.1% ±0.2% (T/N) Supply voltage 12-42 Vdc (up to 28V approved) 9-30 Vdc (up to 24V approved) ±0.3% (B/R/S) Accuracy Depends upon the I/O types and ranges. Refer to the data sheet for the respective model for detail. Response time (0-90%) ≤0.1 sec. ≤0.5 sec., 25 msec. optional Response time (0-90%) ≤2 sec. Operating temperature -40 to +85ºC (-40 to +185ºF) -40 to +80ºC (-40 to +176ºF) Operating temperature -40 to +85ºC (-40 to +185ºF) Insulation resistance ≥100MΩ with 500 Vdc Insulation resistance ≥100MΩ with 500 Vdc Dielectric strength 2000 Vac @1 minute (input to output to ground) Dielectric strength 1500 Vac @1 minute (input to output) CE marking Yes CE marking EMC / ATEX EMC / ATEX EMC Safety approval UL & C-UL ---- Safety approval IS, nonincendive IS, EX, nonincendive IS ---- • Refer to data sheet of respective models for detailed specifications for use in classified locations.

26 27 Two-wire Temperature Transmitters Function Modules

Head Mount Type (Programmable) Two-Input Arithmetic Function Modules Ratio/Bias Modules • Provides a DC signal proportional to the arithmetic function • Precise matching of DC control signals to final control elements 27HU Universal input, HART, Intrinsically safe of two inputs 27U Universal input, Intrinsically safe The PC configurator software is M2REB Output Bias 27TS Thermocouple input, Intrinsically safe available for download free of M2ADS Addition Xo = KXi + B (positive ratio) charge on the M-System web site. 27RS RTD input, Intrinsically safe Output = Input 1 + Input 2 (Output, Input 1 & 2: 0-120 %) Xo = KXi + B + 100% (negative ratio) (K: 0.1 to 4.00 or -0.1 to -4.00, B: ±100%) 27R RTD input, non-isolated, Intrinsically safe http://www.m-system.co.jp/ M2SBS Subtraction • Function monitor LED optional (27R, 27RS) Output = Input 1 – Input 2 (Output, Input 1 & 2: 0-120 %) M2RTS Input Bias • I/O range programming via PC Configurator Xo = K(Xi + B) (positive ratio) M2MLS Multiplication • HART programmable (27HU) USB or RS-232-C Xo = K(Xi + B) + 100% (negative ratio) Output = Input 1 × Input 2 (Output, Input 1 & 2: 0-120 %) (K: 0.1 to 4.00 or -0.1 to -4.00, B: ±100%) Bell202 Modem (model: COP-HU or COP-H) M2DIS Division Output = Input 1÷ Input 2 Square Root Extractor (Output, Input 1: 0-120 %, Input 2: 5-120 %) M2FLS output 24 Vdc Convenient function • Provides a DC signal proportional to the actual flow monitor LED! Input 4-20 mAdc LOAD High/Low Limiter M2LMS • Prevents DC output from going above or below preset values • Limit range: -10.0 to +105% Field-mount Type Head Mount Type (Fixed range) 27HU-B Universal input, HART / explosion-proof - flameproof 26TS1 Thermocouple input Inverted Output • HART programmable 26RS RTD input M2UDS • 4-digit LED indicator optional 26R1 RTD input, non-isolated • DC output proportional to the inverted input • Stainless steel enclosure optional 26REX RTD input, non-isolated, SPECIFICATIONS ATEX approved • ATEX approvals Filters Series M2 Series • FM Class I, II, III, • Suitable for DIN B type head • Limits the rate-of-change of the output DC voltage input Specific range of -300 to +300 V Division 1 approvals • Linearization, burnout protection, M2CDS Delay Buffer (±30 V for M2REB/M2RTS/M2LMS) cold junction compensation Time constant: 0.5-20 sec. Minimum span 3mV (10mV for M2MLS/M2DIS; Æ (T/C input) standard 100mV for M2REB/M2RTS; 1V for M2FLS; 1-5 V for M2SES) M2CRS Ramp Buffer • Optional 25 msec. response time DC current input Resistor attached to the input terminals. Rate-of-change: 0.5-40 sec. selectable for 26TS1 and 26RS 4-20 mA, 0-10 mA, 10-50 mA, etc. DC current output Specific range of 0-20 mA; e.g. 4-20 mA Hold Function OTHER TWO-WIRE TRANSMITTER & ACCESSORIES Minimum span 1mA • Holds the output signal once the command is received until reset Load resistance ≤750Ω at 4-20 mA 6DV-B 4-digit Loop Powered Indicator, Intrinsically safe 43AL-B 3 1/2 digit Loop Powered Indicator, M2AMS Track/Hold DC voltage output Specific range of -10 to +12 V; e.g. 1-5 V, 0-10 V Explosion-proof - flameproof, Field-mount Explosion-proof - flameproof, Field-mount Output held at the command Minimum span 5mV 6DV 4-digit Loop Powered Indicator, Intrinsically safe • 4-20 mA input powered M2PHS Peak/Valley Hold Load resistance ≥5kΩ at 1-5 V • No external power source required • 4-20 mA input powered Responds only to increasing or decreasing signals Power input 24 Vdc or 100-240 Vac • No external power source required Response time (0-90%)≤0.5 sec. • Scaling & linearization selectable via the front control buttons High/Low Selector Operating temperature-5 to +55ºC (23 to 131ºF) • Mountable on top of head-mount transmitter, ≥ Ω installed together in an outdoor enclosure M2SES Insulation resistance 100M with 500 Vdc • Selects either higher or lower of two input signals Dielectric strength 2000 Vac @1 minute (input to output to power to ground) MD6 Series Surge Protectors CE marking Yes Safety approval UL & C-UL nonincendive • Directly mountable to the cable conduit of two-wire transmitters and other field FUNCTION MODULES I/O CHARACTERISTICS devices in an outdoor enclosure • Intrinsically safe / explosion-proof - M2LMS M2UDS M2CDS M2CRS M2AMS M2PHS A3DYH Galvanic Isolator, HART flameproof approvals PEAK HOLD INPUT transmitter excitation supply H • Isolated intrinsically safe associated OUTPUT apparatus - No need of grounding COP-H Bell202 Modem RS-232C interface • Isolates and relays HART signal COP-HU Bell202 Modem USB interface L HOLD bidirectionally • Connects a HART transmitter to PC for programming

28 29 Two-wire Temperature Transmitters Function Modules

Head Mount Type (Programmable) Two-Input Arithmetic Function Modules Ratio/Bias Modules • Provides a DC signal proportional to the arithmetic function • Precise matching of DC control signals to final control elements 27HU Universal input, HART, Intrinsically safe of two inputs 27U Universal input, Intrinsically safe The PC configurator software is M2REB Output Bias 27TS Thermocouple input, Intrinsically safe available for download free of M2ADS Addition Xo = KXi + B (positive ratio) charge on the M-System web site. 27RS RTD input, Intrinsically safe Output = Input 1 + Input 2 (Output, Input 1 & 2: 0-120 %) Xo = KXi + B + 100% (negative ratio) (K: 0.1 to 4.00 or -0.1 to -4.00, B: ±100%) 27R RTD input, non-isolated, Intrinsically safe http://www.m-system.co.jp/ M2SBS Subtraction • Function monitor LED optional (27R, 27RS) Output = Input 1 – Input 2 (Output, Input 1 & 2: 0-120 %) M2RTS Input Bias • I/O range programming via PC Configurator Xo = K(Xi + B) (positive ratio) M2MLS Multiplication • HART programmable (27HU) USB or RS-232-C Xo = K(Xi + B) + 100% (negative ratio) Output = Input 1 × Input 2 (Output, Input 1 & 2: 0-120 %) (K: 0.1 to 4.00 or -0.1 to -4.00, B: ±100%) Bell202 Modem (model: COP-HU or COP-H) M2DIS Division Output = Input 1÷ Input 2 Square Root Extractor (Output, Input 1: 0-120 %, Input 2: 5-120 %) M2FLS output 24 Vdc Convenient function • Provides a DC signal proportional to the actual flow monitor LED! Input 4-20 mAdc LOAD High/Low Limiter M2LMS • Prevents DC output from going above or below preset values • Limit range: -10.0 to +105% Field-mount Type Head Mount Type (Fixed range) 27HU-B Universal input, HART / explosion-proof - flameproof 26TS1 Thermocouple input Inverted Output • HART programmable 26RS RTD input M2UDS • 4-digit LED indicator optional 26R1 RTD input, non-isolated • DC output proportional to the inverted input • Stainless steel enclosure optional 26REX RTD input, non-isolated, SPECIFICATIONS ATEX approved • ATEX approvals Filters Series M2 Series • FM Class I, II, III, • Suitable for DIN B type head • Limits the rate-of-change of the output DC voltage input Specific range of -300 to +300 V Division 1 approvals • Linearization, burnout protection, M2CDS Delay Buffer (±30 V for M2REB/M2RTS/M2LMS) cold junction compensation Time constant: 0.5-20 sec. Minimum span 3mV (10mV for M2MLS/M2DIS; Æ (T/C input) standard 100mV for M2REB/M2RTS; 1V for M2FLS; 1-5 V for M2SES) M2CRS Ramp Buffer • Optional 25 msec. response time DC current input Resistor attached to the input terminals. Rate-of-change: 0.5-40 sec. selectable for 26TS1 and 26RS 4-20 mA, 0-10 mA, 10-50 mA, etc. DC current output Specific range of 0-20 mA; e.g. 4-20 mA Hold Function OTHER TWO-WIRE TRANSMITTER & ACCESSORIES Minimum span 1mA • Holds the output signal once the command is received until reset Load resistance ≤750Ω at 4-20 mA 6DV-B 4-digit Loop Powered Indicator, Intrinsically safe 43AL-B 3 1/2 digit Loop Powered Indicator, M2AMS Track/Hold DC voltage output Specific range of -10 to +12 V; e.g. 1-5 V, 0-10 V Explosion-proof - flameproof, Field-mount Explosion-proof - flameproof, Field-mount Output held at the command Minimum span 5mV 6DV 4-digit Loop Powered Indicator, Intrinsically safe • 4-20 mA input powered M2PHS Peak/Valley Hold Load resistance ≥5kΩ at 1-5 V • No external power source required • 4-20 mA input powered Responds only to increasing or decreasing signals Power input 24 Vdc or 100-240 Vac • No external power source required Response time (0-90%)≤0.5 sec. • Scaling & linearization selectable via the front control buttons High/Low Selector Operating temperature-5 to +55ºC (23 to 131ºF) • Mountable on top of head-mount transmitter, ≥ Ω installed together in an outdoor enclosure M2SES Insulation resistance 100M with 500 Vdc • Selects either higher or lower of two input signals Dielectric strength 2000 Vac @1 minute (input to output to power to ground) MD6 Series Surge Protectors CE marking Yes Safety approval UL & C-UL nonincendive • Directly mountable to the cable conduit of two-wire transmitters and other field FUNCTION MODULES I/O CHARACTERISTICS devices in an outdoor enclosure • Intrinsically safe / explosion-proof - M2LMS M2UDS M2CDS M2CRS M2AMS M2PHS A3DYH Galvanic Isolator, HART flameproof approvals PEAK HOLD INPUT transmitter excitation supply H • Isolated intrinsically safe associated OUTPUT apparatus - No need of grounding COP-H Bell202 Modem RS-232C interface • Isolates and relays HART signal COP-HU Bell202 Modem USB interface L HOLD bidirectionally • Connects a HART transmitter to PC for programming

28 29 M7E Series Limit Alarms High-performance Dual / Quad Limit Alarms with LCD Display High-performance Dual / Quad Limit Alarms

AS4 Series KS2 Series Compact size: 29.5 mm wide • Engineering unit display • 1/16 DIN panel cutout Front LCD display indicates process values and alarm trip conditions • Configurable input sensor type and range • Front digital displays • Dual or quad alarm trip • Dual alarm trip Intuitive, easy programming just like operating a cell phone PC Configurator is also available 2000 Vac isolation M-System’s M7E Series is a 29.5-mm wide space-saving limit alarm. A transreflective FSTN LCD display of 68 x 95 pixel size is provided on the front panel, which is used to show process values and program the module. With the clear, multi-line display’s help, programming using the front four AS4V AS4T AS4LC KS2V control buttons is as easy as that of your mobile phone. The alarm module is plugged into a 11-pin relay socket and fixed firmly with the knurled knob which can be pushed into the front panel. AS4V DC mV, V & mA input AS4T Thermocouple input AS4LC Strain gauge input KS2V DC voltage input AS4R RTD input KS2TR Temperature input AS4M Potentiometer input You won’t need to consult the AS4CT CT (AC current) input instruction manual! SMOOTH PUMP OPERATION The LCD display will show you the parameters and selections INPUT to guide you through the programming of the M7EASV. We are trying to control the level of liquid in a tank by staging four pumps that are Q connected in parallel (see figure). However, the continuously changing liquid level AS4V Set Up Transmitter Input Calibration Set 0%/100% range causes pumps to cycle ON and OFF sporadically around the setpoints. How can we solve this problem? L1 L2 L3 L4 Fine Adjustment Adjust 0%/100% input MODEL FUNCTION You will need to set a deadband (hysteresis) for each pump’s control setpoint. Scaling Unit A With or dinary limit alarms, you might have to set two trip points for each pump to P1 P2 P3 P4 M7EASV DC mV, V, mA input accomplish this result. The AS4V can be field programmed to eliminate the unwanted pump Select unit cycling, giving you consistant pump operations and control. (A, mA, V, mV, W, Current loop supply (4-20 mA input with mW, %, ºC, ºF, Ω, Pa, M7EASDY kPa, MPa, User Unit) 2-wire transmitter excitation) Main contents list Setup menu SPECIFICATIONS User Unit Setting Alarm Alarm Value Series AS4 Series KS2 Series

Decimal Point Model No. AS4V AS4T AS4R AS4M AS4CT AS4LC KS2V KS2TR Set L1...L4 in SPECIFICATIONS engineering unit Selectable 0-50 mA K, E, J, T Pt 100 100 to 10kΩ 0-1 Aac 0.0-3.0 mV/V 1-5 V K, E, J, T Select decimal point Series M7E Series input ±1V B, R, S Pt 1000 0-5 Aac 0.0-10.0 mV/V B, R, S Trip Operation Model No. M7EASV M7EASDY ±10V C (WRe 5-26) Ni 508.4 0.0-30.0 mV/V C (WRe 5-26) Set Scale Input 0-50 mA, ±1V, ±10V: 4-20 mA N, U, L Ni 100, N, PL2 Select Hi / Lo Selectable range within Excitation: 24-28 Vdc wtih P (Platinel II) Cu 10 Pt 100 Set 0%/100% scale each input type no load, 22mA Alarm points Dual or quad (Hi or Lo configurable for each input) Dual (Hi or Lo configurable) Coil at Alarm Alarm points Dual or quad (Hi or Lo configurable for each input) Relay contact Quad: 120 Vac, 30 Vdc @1A, 240 Vac @0.5A 120 Vac, 30 Vdc @1A 220 Vac @3A Select Energize Relay contact Quad: 120 Vac, 30 Vdc @1A, 240 Vac @0.5A Dual: 120 Vac, 30 Vdc @5A, 240 Vac @2.5A 240 Vac @0.5A 30 Vdc @3A / De-energize Dual: 120 Vac, 30 Vdc @4A, 240 Vac @2A DC power 24 Vdc, 110 Vdc 24 Vdc

Power ON Delay Timer Time Setting DC power 24 Vdc AC power 100-240 Vac 100-240 Vac (0-99 sec.) AC power 100-240 Vac Set accuracy ± (0.1% of FS + 1 digit) (0.2% for Cu 10, 0.3% for AS4CT) ±0.1% FS Engineering Alarm ON Delay Timer Time Setting unit selections ± ≤ ≤ ≤ ≤ ≤ (0-999 sec.) Set accuracy (0.1% of FS + 1 digit) Response time 0.5 sec. 1.5 sec. 0.5 sec. 0.7 sec. 1.5 sec. ---- Response time ≤0.5 sec. Operating temperature-5 to +55ºC (23 to 131ºF) -10 to +50ºC (14 to 122ºF) Moving Average Number of Samples Operating temperature -5 to +55ºC (23 to 131ºF) Insulation resistance≥100MΩ with 500 Vdc ≥50MΩ with 500 Vdc Hysteresis Set L1...L4 in ≥ Ω (deadband) engineering unit Insulation resistance 100M with 500 Vdc Dielectric 2000 Vac @1 minute (input to output to power to ground) 1500 Vac @1 minute Dielectric strength 2000 Vac @1 minute strength (input to SET1/SET2 to power) Latching Enable / Disable User's unit (input to output to power to ground) Setpoint adj. -1999 to 9999 -272 to 2416 -240 to 900 -1999 to 9999 -5 to +105% setting (e.g. N•m) Setpoint adj. -9999 to 9999 Deadband 1 to 99990.0 to 2416 0 to 900 1 to 9999 0 to 102% LCD Mode Deadband 1 to 9999 Scaling -1999 to 9999 -272 to 2416-240 to 900 -1999 to 9999 -1999 to 9999 Information Mode Scaling -9999 to 9999 (with engineering unit on display) Read rate 100 msec. 0.5 sec. Alarm Test Mode Display rate 150 msec. Other Failsafe operation, latching, power/alarm ON delay, moving average filter, power-saving mode Failsafe, power/alarm ON

Parameter Lock Other features Failsafe operation, latching, power/alarm ON features delay, First order lag filter Alarm setpoints in Contrast delay, moving average filter, alarm test mode CE marking Yes Yes enginerring unit value adjustment CE marking Yes Safety approval UL & C-UL ---- UL & C-UL

30

31 M7E Series Limit Alarms High-performance Dual / Quad Limit Alarms with LCD Display High-performance Dual / Quad Limit Alarms

AS4 Series KS2 Series Compact size: 29.5 mm wide • Engineering unit display • 1/16 DIN panel cutout Front LCD display indicates process values and alarm trip conditions • Configurable input sensor type and range • Front digital displays • Dual or quad alarm trip • Dual alarm trip Intuitive, easy programming just like operating a cell phone PC Configurator is also available 2000 Vac isolation M-System’s M7E Series is a 29.5-mm wide space-saving limit alarm. A transreflective FSTN LCD display of 68 x 95 pixel size is provided on the front panel, which is used to show process values and program the module. With the clear, multi-line display’s help, programming using the front four AS4V AS4T AS4LC KS2V control buttons is as easy as that of your mobile phone. The alarm module is plugged into a 11-pin relay socket and fixed firmly with the knurled knob which can be pushed into the front panel. AS4V DC mV, V & mA input AS4T Thermocouple input AS4LC Strain gauge input KS2V DC voltage input AS4R RTD input KS2TR Temperature input AS4M Potentiometer input You won’t need to consult the AS4CT CT (AC current) input instruction manual! SMOOTH PUMP OPERATION The LCD display will show you the parameters and selections INPUT to guide you through the programming of the M7EASV. We are trying to control the level of liquid in a tank by staging four pumps that are Q connected in parallel (see figure). However, the continuously changing liquid level AS4V Set Up Transmitter Input Calibration Set 0%/100% range causes pumps to cycle ON and OFF sporadically around the setpoints. How can we solve this problem? L1 L2 L3 L4 Fine Adjustment Adjust 0%/100% input MODEL FUNCTION You will need to set a deadband (hysteresis) for each pump’s control setpoint. Scaling Unit A With or dinary limit alarms, you might have to set two trip points for each pump to P1 P2 P3 P4 M7EASV DC mV, V, mA input accomplish this result. The AS4V can be field programmed to eliminate the unwanted pump Select unit cycling, giving you consistant pump operations and control. (A, mA, V, mV, W, Current loop supply (4-20 mA input with mW, %, ºC, ºF, Ω, Pa, M7EASDY kPa, MPa, User Unit) 2-wire transmitter excitation) Main contents list Setup menu SPECIFICATIONS User Unit Setting Alarm Alarm Value Series AS4 Series KS2 Series

Decimal Point Model No. AS4V AS4T AS4R AS4M AS4CT AS4LC KS2V KS2TR Set L1...L4 in SPECIFICATIONS engineering unit Selectable 0-50 mA K, E, J, T Pt 100 100 to 10kΩ 0-1 Aac 0.0-3.0 mV/V 1-5 V K, E, J, T Select decimal point Series M7E Series input ±1V B, R, S Pt 1000 0-5 Aac 0.0-10.0 mV/V B, R, S Trip Operation Model No. M7EASV M7EASDY ±10V C (WRe 5-26) Ni 508.4 0.0-30.0 mV/V C (WRe 5-26) Set Scale Input 0-50 mA, ±1V, ±10V: 4-20 mA N, U, L Ni 100, N, PL2 Select Hi / Lo Selectable range within Excitation: 24-28 Vdc wtih P (Platinel II) Cu 10 Pt 100 Set 0%/100% scale each input type no load, 22mA Alarm points Dual or quad (Hi or Lo configurable for each input) Dual (Hi or Lo configurable) Coil at Alarm Alarm points Dual or quad (Hi or Lo configurable for each input) Relay contact Quad: 120 Vac, 30 Vdc @1A, 240 Vac @0.5A 120 Vac, 30 Vdc @1A 220 Vac @3A Select Energize Relay contact Quad: 120 Vac, 30 Vdc @1A, 240 Vac @0.5A Dual: 120 Vac, 30 Vdc @5A, 240 Vac @2.5A 240 Vac @0.5A 30 Vdc @3A / De-energize Dual: 120 Vac, 30 Vdc @4A, 240 Vac @2A DC power 24 Vdc, 110 Vdc 24 Vdc

Power ON Delay Timer Time Setting DC power 24 Vdc AC power 100-240 Vac 100-240 Vac (0-99 sec.) AC power 100-240 Vac Set accuracy ± (0.1% of FS + 1 digit) (0.2% for Cu 10, 0.3% for AS4CT) ±0.1% FS Engineering Alarm ON Delay Timer Time Setting unit selections ± ≤ ≤ ≤ ≤ ≤ (0-999 sec.) Set accuracy (0.1% of FS + 1 digit) Response time 0.5 sec. 1.5 sec. 0.5 sec. 0.7 sec. 1.5 sec. ---- Response time ≤0.5 sec. Operating temperature-5 to +55ºC (23 to 131ºF) -10 to +50ºC (14 to 122ºF) Moving Average Number of Samples Operating temperature -5 to +55ºC (23 to 131ºF) Insulation resistance≥100MΩ with 500 Vdc ≥50MΩ with 500 Vdc Hysteresis Set L1...L4 in ≥ Ω (deadband) engineering unit Insulation resistance 100M with 500 Vdc Dielectric 2000 Vac @1 minute (input to output to power to ground) 1500 Vac @1 minute Dielectric strength 2000 Vac @1 minute strength (input to SET1/SET2 to power) Latching Enable / Disable User's unit (input to output to power to ground) Setpoint adj. -1999 to 9999 -272 to 2416 -240 to 900 -1999 to 9999 -5 to +105% setting (e.g. N•m) Setpoint adj. -9999 to 9999 Deadband 1 to 99990.0 to 2416 0 to 900 1 to 9999 0 to 102% LCD Mode Deadband 1 to 9999 Scaling -1999 to 9999 -272 to 2416-240 to 900 -1999 to 9999 -1999 to 9999 Information Mode Scaling -9999 to 9999 (with engineering unit on display) Read rate 100 msec. 0.5 sec. Alarm Test Mode Display rate 150 msec. Other Failsafe operation, latching, power/alarm ON delay, moving average filter, power-saving mode Failsafe, power/alarm ON

Parameter Lock Other features Failsafe operation, latching, power/alarm ON features delay, First order lag filter Alarm setpoints in Contrast delay, moving average filter, alarm test mode CE marking Yes Yes enginerring unit value adjustment CE marking Yes Safety approval UL & C-UL ---- UL & C-UL

30

31 Limit Alarms Analog Limit Alarms LT Series Power Transducers

Plug-in Design Compact Plug-in Design True RMS sensing Surface or DIN rail mounting M4 screw terminal Conform to IEC 60688 MSEF ASD1 Optional terminal cover Additional pulse rate output for M2AVS M2SED totalizing counter (Watt Transducer)

AYDV KSED

MSEF Front Control Button Adjustment, Dual Alarm M2AVS Potentiometer Adjustment, Dual Alarm AYDV Potentiometer Adjustment, Dual Deviation Alarm M2SED Thumbwheel Switch Adjustment, Dual Alarm, SPDT ASD1 Thumbwheel Switch Adjustment, Dual Alarm M2AS Thumbwheel Switch Adjustment, Single Alarm, DPDT KSED Thumbwheel Switch Adjustment, Dual Alarm M2AS1 Thumbwheel Switch Adjustment, Single Alarm, SPDT

AC Current & Voltage Transducers AL Series AE Series MODEL FUNCTION Direct Sensor Input, SPDT Alarm Direct Sensor Input, SPDT plus LTCNE AC Current Transducer (self-powered) • Input DC, T/C, RTD, Pot, Pulse, DC Transmitter Output LTCE AC Current Transducer AC, 2-wire Transmitter • Input DC, T/C, RTD, Pot, Pulse, AC, • Output 120 Vac or 30 Vdc @1A; 2-wire Transmitter LTCEC AC Current Transducer (clamp-on current sensor) 240 Vac @0.5A • Output 120 Vac or 30 Vdc @1A; LTPE AC Voltage Transducer Clamp-on Current Sensor (For details, refer to Signal Conditioners Data 240 Vac @0.5A Library at www.m-system.com) • Specific DC output range within -10 to +12 V or 0-20 mA Power Transducers SPECIFICATIONS (For details, refer to Signal Conditioners Data Library at www.m-system.com) MODEL FUNCTION Series LT Series SPECIFICATIONS Configuration Three-phase/3- or 4-wire LTWT Watt Transducer Series M-UNIT K-UNIT M2 Series Single-phase/2- or 3-wire LTWTN Watt Transducer (self-powered) Model No. MSEF AYDV ASD1 KSED M2AVS M2SED M2AS / M2AS1 VT input 100, 110, 115, 120, 190, 200, 210, 220, LTRP Var Transducer 230, 240, 380, 400, 415, 430, 440, 480 Vac, Input (specified 4-20 mA, 2-10 mA1-5 V, 4-20 mA 4-20 mA 4-20 mA Specific range 4-20 mA, 0-10 V, 0-5 V, 1-5 V 100/200 Vac when ordering) 1-5 mA, 0-10 V 10-50 mA 0-10 V, 0-10 V of -300 to +300 LTRPN Var Transducer (self-powered) 0-5 V, 1-5 V (reference 1-5 V) 0-5 V, 1-5 V 0-5 V, 1-5 V V CT input 1A, 2A, 5A LTPF/LTPFU Power Factor Transducer Alarm points Dual (Hi/Lo selectable) Dual Dual (Hi/Lo) Dual Dual (Hi/Lo) Single Frequency input (HZ) 45-55 Hz, 55-65 Hz, 45-65 Hz (Hi/Lo selectable) (Hi/Lo selectable) (Hi/Lo selectable) LTPFN/LTPFUN Power Factor Transducer (self-powered) DC current output Specific range of -10 to +20 mA; e.g. 4-20 mA Relay contact SPDT SPDT SPDT N.O. SPDT DPDT / SPDT LTPA/LTPAU Phase Angle Transducer Minimum span 1mA ≤ Ω Rated load 120 Vac @5A 120 Vac @1A 120 Vac @5A 120 Vac @5A 120 Vac @0.5A 120 Vac @5A LTPAN/LTPAUN Phase Angle Transducer (self-powered) Load resistance 500 at 4-20 mA 240 Vac @2.5A 240 Vac @0.5A 240 Vac @2.5A 240 Vac @2.5A 240 Vac @0.5A 240 Vac @2.5A DC voltage output Specific range of -10 to +12 V e.g. 1-5 V, 0-10 V 30 Vdc @5A 30 Vdc @1A 30 Vdc @5A 30 Vdc @5A 30 Vdc @0.5A 30 Vdc @5A LTHZ Frequency Transducer (negative output not available for VT/CT) DC power input 12, 24 Vdc 12, 24, 48, 110 Vdc------24 Vdc LTHZN Frequency Transducer (self-powered) Minimum span 5mV AC power input 100, 110, 115, 120 Vac 100-120 Vac 100-120 Vac 100-240 Vac Load resistance ≥5kΩ at 1-5 V 200, 220, 240 Vac 200-240 Vac 200-240 Vac Pulse output (WT) 2.777 Hz at 100% or customer specified pulse unit ± ± ± ± ± ± Multi Power Transducer Set accuracy 0.5% 0.5% 0.5% 0.5% monitor 0.5% 0.5% Power input 24, 48 Vdc or 100-120, 200-240 Vac ≤ ≤ ≤ ± ≤ LSMT3 Response time 0.5 sec. ---- 0.7 sec. 0.5 sec. 0.5 0.2 sec. 0.5 sec. Accuracy ±0.2 % for VT, CT, WT • Measures AC current, voltage, active/ Operating temperature-5 to +60ºC (23 to +140ºF) -5 to +55ºC (23 to 131ºF) Response time (0-90%) ≤1 sec. for VT, CT; ≤2 sec. for WT ≥ Ω reactive/apparent power and power factor Insulation resistance 100M with 500 Vdc Operating temperature -10 to +55ºC (14 to 131ºF) • AC/DC universal power input Dielectric strength 2000 Vac @1 minute (input to output to power to ground) Insulation resistance ≥100MΩ with 500 Vdc Setpoint adj. -10 to +110% -50 to +50% 0 to 99% 0 to 99% 0 to 100% 0 to 99% • Conforms to IEC 688 • CE marking Dielectric strength 2000 Vac @1 minute Deadband 0.5 to 15% 0.2 ±0.1% 0.5, 1 to 14% 1% ≤0.5% 1±0.3% 1 to 99% (input to output to power to ground) CE marking Yes ---- Yes Yes (24 Vdc) Yes Yes Impulse withstand voltage1.2/50 µsec. ±5kV Safety approval UL & C-UL ---- UL & C-UL ---- UL & C-UL ---- CE marking Yes (except LTCNE / LTCEC)

32 33 Limit Alarms Analog Limit Alarms LT Series Power Transducers

Plug-in Design Compact Plug-in Design True RMS sensing Surface or DIN rail mounting M4 screw terminal Conform to IEC 60688 MSEF ASD1 Optional terminal cover Additional pulse rate output for M2AVS M2SED totalizing counter (Watt Transducer)

AYDV KSED

MSEF Front Control Button Adjustment, Dual Alarm M2AVS Potentiometer Adjustment, Dual Alarm AYDV Potentiometer Adjustment, Dual Deviation Alarm M2SED Thumbwheel Switch Adjustment, Dual Alarm, SPDT ASD1 Thumbwheel Switch Adjustment, Dual Alarm M2AS Thumbwheel Switch Adjustment, Single Alarm, DPDT KSED Thumbwheel Switch Adjustment, Dual Alarm M2AS1 Thumbwheel Switch Adjustment, Single Alarm, SPDT

AC Current & Voltage Transducers AL Series AE Series MODEL FUNCTION Direct Sensor Input, SPDT Alarm Direct Sensor Input, SPDT plus LTCNE AC Current Transducer (self-powered) • Input DC, T/C, RTD, Pot, Pulse, DC Transmitter Output LTCE AC Current Transducer AC, 2-wire Transmitter • Input DC, T/C, RTD, Pot, Pulse, AC, • Output 120 Vac or 30 Vdc @1A; 2-wire Transmitter LTCEC AC Current Transducer (clamp-on current sensor) 240 Vac @0.5A • Output 120 Vac or 30 Vdc @1A; LTPE AC Voltage Transducer Clamp-on Current Sensor (For details, refer to Signal Conditioners Data 240 Vac @0.5A Library at www.m-system.com) • Specific DC output range within -10 to +12 V or 0-20 mA Power Transducers SPECIFICATIONS (For details, refer to Signal Conditioners Data Library at www.m-system.com) MODEL FUNCTION Series LT Series SPECIFICATIONS Configuration Three-phase/3- or 4-wire LTWT Watt Transducer Series M-UNIT K-UNIT M2 Series Single-phase/2- or 3-wire LTWTN Watt Transducer (self-powered) Model No. MSEF AYDV ASD1 KSED M2AVS M2SED M2AS / M2AS1 VT input 100, 110, 115, 120, 190, 200, 210, 220, LTRP Var Transducer 230, 240, 380, 400, 415, 430, 440, 480 Vac, Input (specified 4-20 mA, 2-10 mA1-5 V, 4-20 mA 4-20 mA 4-20 mA Specific range 4-20 mA, 0-10 V, 0-5 V, 1-5 V 100/200 Vac when ordering) 1-5 mA, 0-10 V 10-50 mA 0-10 V, 0-10 V of -300 to +300 LTRPN Var Transducer (self-powered) 0-5 V, 1-5 V (reference 1-5 V) 0-5 V, 1-5 V 0-5 V, 1-5 V V CT input 1A, 2A, 5A LTPF/LTPFU Power Factor Transducer Alarm points Dual (Hi/Lo selectable) Dual Dual (Hi/Lo) Dual Dual (Hi/Lo) Single Frequency input (HZ) 45-55 Hz, 55-65 Hz, 45-65 Hz (Hi/Lo selectable) (Hi/Lo selectable) (Hi/Lo selectable) LTPFN/LTPFUN Power Factor Transducer (self-powered) DC current output Specific range of -10 to +20 mA; e.g. 4-20 mA Relay contact SPDT SPDT SPDT N.O. SPDT DPDT / SPDT LTPA/LTPAU Phase Angle Transducer Minimum span 1mA ≤ Ω Rated load 120 Vac @5A 120 Vac @1A 120 Vac @5A 120 Vac @5A 120 Vac @0.5A 120 Vac @5A LTPAN/LTPAUN Phase Angle Transducer (self-powered) Load resistance 500 at 4-20 mA 240 Vac @2.5A 240 Vac @0.5A 240 Vac @2.5A 240 Vac @2.5A 240 Vac @0.5A 240 Vac @2.5A DC voltage output Specific range of -10 to +12 V e.g. 1-5 V, 0-10 V 30 Vdc @5A 30 Vdc @1A 30 Vdc @5A 30 Vdc @5A 30 Vdc @0.5A 30 Vdc @5A LTHZ Frequency Transducer (negative output not available for VT/CT) DC power input 12, 24 Vdc 12, 24, 48, 110 Vdc------24 Vdc LTHZN Frequency Transducer (self-powered) Minimum span 5mV AC power input 100, 110, 115, 120 Vac 100-120 Vac 100-120 Vac 100-240 Vac Load resistance ≥5kΩ at 1-5 V 200, 220, 240 Vac 200-240 Vac 200-240 Vac Pulse output (WT) 2.777 Hz at 100% or customer specified pulse unit ± ± ± ± ± ± Multi Power Transducer Set accuracy 0.5% 0.5% 0.5% 0.5% monitor 0.5% 0.5% Power input 24, 48 Vdc or 100-120, 200-240 Vac ≤ ≤ ≤ ± ≤ LSMT3 Response time 0.5 sec. ---- 0.7 sec. 0.5 sec. 0.5 0.2 sec. 0.5 sec. Accuracy ±0.2 % for VT, CT, WT • Measures AC current, voltage, active/ Operating temperature-5 to +60ºC (23 to +140ºF) -5 to +55ºC (23 to 131ºF) Response time (0-90%) ≤1 sec. for VT, CT; ≤2 sec. for WT ≥ Ω reactive/apparent power and power factor Insulation resistance 100M with 500 Vdc Operating temperature -10 to +55ºC (14 to 131ºF) • AC/DC universal power input Dielectric strength 2000 Vac @1 minute (input to output to power to ground) Insulation resistance ≥100MΩ with 500 Vdc Setpoint adj. -10 to +110% -50 to +50% 0 to 99% 0 to 99% 0 to 100% 0 to 99% • Conforms to IEC 688 • CE marking Dielectric strength 2000 Vac @1 minute Deadband 0.5 to 15% 0.2 ±0.1% 0.5, 1 to 14% 1% ≤0.5% 1±0.3% 1 to 99% (input to output to power to ground) CE marking Yes ---- Yes Yes (24 Vdc) Yes Yes Impulse withstand voltage1.2/50 µsec. ±5kV Safety approval UL & C-UL ---- UL & C-UL ---- UL & C-UL ---- CE marking Yes (except LTCNE / LTCEC)

32 33 53U Multi Power Monitor Remote I/O

Single-phase/2-wire and 3-wire, three-phase/3-wire, 4-wire systems Hot Swappable, Fully Isolated Remote I/O Three line measured value/bargraph Broad I/O Offering: Scalable and Flexible indicators plus energy count/info display Redundant Communications: Programming lock to prevent unwanted Reliable and Flexible configuration changes Redundant Power for High Reliability IP 50 front panel Output options – Modbus, Ao, Do selectable NEW High accuracy (Option) NEW M-System’s model 53U is a 96-mm-square Multi LCD Power Monitor mounted on a panel surface. One model can be used for single-phase/2-wire and 3-wire, three-phase/3-wire and 4-wire systems. Users can freely choose and M-System’s Remote I/O is designed to support DCS/PLC systems by expanding their I/O flexibility and capabilities in addition to program major variables in heavy-current power systems, such like AC voltage/current, active/reactive power, power factor, AC providing all full channel-to-channel isolation. The Remote I/O communicates directly to the PLC and DCS via industry standard frequency deviation, apparent power, active/reactive energy and up-to-the-31st harmonic distortions. open-protocol networks. Measured variables also include the maximum/minimum/average values, in total of 500 types. Up to 1800 patterns of display M-System’s Remote I/O also can be used as stand-alone distributed I/O communicating with popular HMI software. combinations are available. The Remote I/O can be located remotely in the field, or within an instrumentation cabinet such as test stands. All measured variables can be transmitted to the host PC via RS-485/Modbus RTU. Conversion factors, system configuration, interval The flexibility and scalability of M-System’s Remote I/O supports future system upgrades with full isolation between times are programmable using the front keys, or the PC Configurator Software locally or remotely. Measured values, counter values, power-communication-I/O and between analog channels. Economical non-isolated analog modules are also selectable. display mode, setting data are stored in the non-volatile memory at the power off. Isolated analog I/O modules provide high-performance signal conversion/conditioning and complete three-way plus An open collector output can be used for energy count pulse or limit alarm trip. Pulse rate for energy count can be specified. The channel-to-channel isolation. This ensures you a highly dependable system. contact output can be simulated for testing the connected device. Applications include: signal concentrator, data collection in flow and level monitoring, injection molding monitoring and control, External open collector input is typically used to reset energy count memory. The signal can be also monitored at the host system via test stands and prototyping, glass furnace temperature control, assembly line discrete ON/OFF, paint booth environment reporting, Modbus, so that the host can start/stop monitoring according to ON/OFF status of a load (e.g. motor running or not). pharmaceutical processes. SPECIFICATIONS Enhanced PC Configurator Software with Model No. 53U Monitoring Function Configuration Three-phase/3- and 4-wire Remote I/O Replacement Remote I/O Can Replace PLC Single-phase/2- and 3-wire for PLC and DCS in PC-Based SCADA Systems VT input 480 Vac PC PC CT input 1A, 5A

Contact input 24 Vdc or 110 Vdc Ethernet External interface Modbus, Do x 1 points, Di x 1 points; Modbus, Do x 3 points; Do x 4 points; Gateway / Ao x 2 points, Do x 1 points, Di x 1 points; Protocol Converter PLC/DCS Configuration window Ao x 2 points, Do x 2 points; Ao x 4 points; Open Field Network Open Field Network (Modbus, etc) R3 Series R5 Series Accuracy voltage/current: ±0.3% (±0.2% optional) power/power factor: ±0.5% Monitoring window frequency: ±0.1% energy/harmonic contents: ±1% (±0.5% for energy optional) R1 Series R1 Series 53U Monitoring & Logging Software Analog output: Accuracy of assigned measurand R3 Series R5 Series R3 Series R5 Series or ±0.2%, whichever is greater. PC Recorder software is available Response time (0-90%) ≤2 sec. for use with the 53U. Ai/o, Di/o Ai/o, Di/o Ai/o, Di/o Ai/o, Di/o Ai/o, Di/o Ai/o, Di/o Operating temperature -10 to +55ºC (14 to 131ºF) Insulation resistance ≥100MΩ with 500 Vdc M-System's Remote I/O is designed to support DCS/PLC M-System’s Remote I/O can also be used as stand-alone distributed I/O Dielectric strength 4000 Vac @1 minute systems by expanding their I/O flexibility and capabilities in communicating with popular HMI software such as Citect, Intellution and (between power input to other field terminals) addition to providing all full channel-to-channel isolation. Wonderware. The Remote I/O can be located remotely in the field, or within 2500 Vac @1 minute (between other field terminals except power input) The Remote I/O communicates directly to the PLC and DCS an instrumentation cabinet such as test stands. via industry standard open-protocol networks. CE marking Yes

34

35 53U Multi Power Monitor Remote I/O

Single-phase/2-wire and 3-wire, three-phase/3-wire, 4-wire systems Hot Swappable, Fully Isolated Remote I/O Three line measured value/bargraph Broad I/O Offering: Scalable and Flexible indicators plus energy count/info display Redundant Communications: Programming lock to prevent unwanted Reliable and Flexible configuration changes Redundant Power for High Reliability IP 50 front panel Output options – Modbus, Ao, Do selectable NEW High accuracy (Option) NEW M-System’s model 53U is a 96-mm-square Multi LCD Power Monitor mounted on a panel surface. One model can be used for single-phase/2-wire and 3-wire, three-phase/3-wire and 4-wire systems. Users can freely choose and M-System’s Remote I/O is designed to support DCS/PLC systems by expanding their I/O flexibility and capabilities in addition to program major variables in heavy-current power systems, such like AC voltage/current, active/reactive power, power factor, AC providing all full channel-to-channel isolation. The Remote I/O communicates directly to the PLC and DCS via industry standard frequency deviation, apparent power, active/reactive energy and up-to-the-31st harmonic distortions. open-protocol networks. Measured variables also include the maximum/minimum/average values, in total of 500 types. Up to 1800 patterns of display M-System’s Remote I/O also can be used as stand-alone distributed I/O communicating with popular HMI software. combinations are available. The Remote I/O can be located remotely in the field, or within an instrumentation cabinet such as test stands. All measured variables can be transmitted to the host PC via RS-485/Modbus RTU. Conversion factors, system configuration, interval The flexibility and scalability of M-System’s Remote I/O supports future system upgrades with full isolation between times are programmable using the front keys, or the PC Configurator Software locally or remotely. Measured values, counter values, power-communication-I/O and between analog channels. Economical non-isolated analog modules are also selectable. display mode, setting data are stored in the non-volatile memory at the power off. Isolated analog I/O modules provide high-performance signal conversion/conditioning and complete three-way plus An open collector output can be used for energy count pulse or limit alarm trip. Pulse rate for energy count can be specified. The channel-to-channel isolation. This ensures you a highly dependable system. contact output can be simulated for testing the connected device. Applications include: signal concentrator, data collection in flow and level monitoring, injection molding monitoring and control, External open collector input is typically used to reset energy count memory. The signal can be also monitored at the host system via test stands and prototyping, glass furnace temperature control, assembly line discrete ON/OFF, paint booth environment reporting, Modbus, so that the host can start/stop monitoring according to ON/OFF status of a load (e.g. motor running or not). pharmaceutical processes. SPECIFICATIONS Enhanced PC Configurator Software with Model No. 53U Monitoring Function Configuration Three-phase/3- and 4-wire Remote I/O Replacement Remote I/O Can Replace PLC Single-phase/2- and 3-wire for PLC and DCS in PC-Based SCADA Systems VT input 480 Vac PC PC CT input 1A, 5A

Contact input 24 Vdc or 110 Vdc Ethernet External interface Modbus, Do x 1 points, Di x 1 points; Modbus, Do x 3 points; Do x 4 points; Gateway / Ao x 2 points, Do x 1 points, Di x 1 points; Protocol Converter PLC/DCS Configuration window Ao x 2 points, Do x 2 points; Ao x 4 points; Open Field Network Open Field Network (Modbus, etc) R3 Series R5 Series Accuracy voltage/current: ±0.3% (±0.2% optional) power/power factor: ±0.5% Monitoring window frequency: ±0.1% energy/harmonic contents: ±1% (±0.5% for energy optional) R1 Series R1 Series 53U Monitoring & Logging Software Analog output: Accuracy of assigned measurand R3 Series R5 Series R3 Series R5 Series or ±0.2%, whichever is greater. PC Recorder software is available Response time (0-90%) ≤2 sec. for use with the 53U. Ai/o, Di/o Ai/o, Di/o Ai/o, Di/o Ai/o, Di/o Ai/o, Di/o Ai/o, Di/o Operating temperature -10 to +55ºC (14 to 131ºF) Insulation resistance ≥100MΩ with 500 Vdc M-System's Remote I/O is designed to support DCS/PLC M-System’s Remote I/O can also be used as stand-alone distributed I/O Dielectric strength 4000 Vac @1 minute systems by expanding their I/O flexibility and capabilities in communicating with popular HMI software such as Citect, Intellution and (between power input to other field terminals) addition to providing all full channel-to-channel isolation. Wonderware. The Remote I/O can be located remotely in the field, or within 2500 Vac @1 minute (between other field terminals except power input) The Remote I/O communicates directly to the PLC and DCS an instrumentation cabinet such as test stands. via industry standard open-protocol networks. CE marking Yes

34

35 Remote I/O Remote I/O R3 Series Multi-channel, Mixed Signal Remote I/O R5 Series Compact, Mixed Signal Remote I/O

Wide selection of I/O modules and network modules Free combination of I/O modules, network modules and power modules. • Great flexibilities in number and type of I/O signals: DC current/voltage, temperature, strain gauge, AC current/voltage, AC power, etc. • Single analog module can handle fully-isolated 2 points. • Hot-swappable I/O modules and power supplies • Hot-swappable I/O modules • Dual redundant communication networks • Dual redundant communication networks and power supplies • 1500 Vac isolation • Space-saving DIN terminal block or heavy-duty screw terminal block selectable for I/O • I/O modules with connector terminal available • 1500 Vac isolation

ANALOG INPUT MODULES ANALOG OUTPUT MODULES ANALOG INPUT MODULES ANALOG OUTPUT MODULES Input Model CH Output Model CH Model Model Input CH Output CH R3-TS4 4 (isolated) R3-YV4 4 (isolated) Euro TerminalScrew Terminal Euro TerminalScrew Terminal Thermocouple DC Voltage Output Input R3-TS8 8 (isolated) R3-YV8 8 (isolated) Thermocouple R5-TS1 R5T-TS1 1 DC Voltage R5-YV1 R5T-YV1 1 4 (isolated) DC Current Output R3-YS4 4 (isolated) R3-RS4 Input R5-TS2 R5T-TS2 2 Output R5-YV2 R5T-YV2 2 RTD Input R3-RS8 8 (isolated) Pulse Output R3-PC16A 16 R5-RS1 R5T-RS1 1 1 R3-RS8A 8 (isolated) 4-20mA R5-YS1 R5T-YS1 Output R3-SV4 ALARM MODULES R5-RS2 R5T-RS2 2 R5-YS2 R5T-YS2 2 R3-SV4B 4 (isolated) RTD Input Input Model CH R5-RSA1 1 R3-SV4C Totalized Pulse 2 Thermocouple Input R3-AT4 4 Output R5-PC2 R5T-PC2 R3-SV8 R5-RSA2 2 DC Voltage RTD Input R3-AR4 4 Input R3-SV8B 8 (isolated) R5T-SV1 R3-SV8C R3-AV4 4 R5-SV1 1 DC Voltage Input DC Voltage R3-SV8N 8 (non-isolated) R3-AV8 8 Input R5-SV2 R5T-SV2 2 DISCRETE MODULES R3-SV16N 16 (non-isolated) R3-AS4 4 Model DC Current Input R5-SS1 R5T-SS1 1 I/O CH DC Millivolt R3-SV4A 4 (isolated) R3-AS8 8 DC Current Euro TerminalScrew Terminal NETWORK MODULES Input Input R3-SV8A 8 (isolated) 4-20mA Input R5-SS2 R5T-SS2 2 R3-AD4 4 NETWORK MODULES Di 4 Points Model Capacity Model Capacity R3-SS4 4 (isolated) with Excitation Input R5-DA4 R5T-DA4 4 4-20mA Input R5-DS1 R5T-DS1 1 Model Capacity R3-NE1 Modbus/TCP (Ethernet) R3-NM1 Modbus DC Current R3-SS8 8 (isolated) with Excitation Input R5-DS2 R5T-DS2 2 R3-SS8N 8 (non-isolated) DISCRETE MODULES Modbus/TCP (Ethernet) Di 16 Points R5-DA16 R3-ND1 Analog 16 ch. R3-NP1 PROFIBUS-DP R5-NE1 16 R3-SS16N 16 (non-isolated) Potentiometer R5-MS1 1 Input (Connector) I/O Model CH Modbus R3-ND2 DeviceNet Analog 32 ch. R3-NL1 R5-NM1 Input ONWORKS R3-DS4 Dry Contact Input R3-DA16 16 R5-MS2 2 L 4-20mA Input 4 (isolated) Analog 16 ch. Do 4 Points Analog 64 ch. R3-DS4A R3-DA16A R5-ND1 R5-DC4 R5T-DC4 4 R3-ND3 R3-NL2 with Excitation 16 DeviceNet R5T-CT1 1 Output 8 (non-isolated) Dry Contact Input T-Link R3-DS8N R3-DA32A 32 R5-ND2 Analog 32 ch. CT Input R3-NC1 Ver. 1; Analog 16 ch. R3-NF1 with External Exc. 2 Potentiometer R3-MS4 4 (isolated) R3-DA64A R5T-CT2 64 R5-NP1 Analog 16 ch. Do 16 Points R5-DC16 16 CC-Link Ver. 1; Analog 32 ch. Input 8 (isolated) (Connector) R3-NC2 R3-MS8 R3-DA16B PROFIBUS-DP R5T-CTA1 1 Output AC Contact Input 16 Analog 32 ch. Ver.2 Strain Gauge Input R3-LC2 2 (isolated) R3-DC16 R5-NP2 R3-NC3 Relay Output 16 AC Current Input R5T-CTA2 2 CT Input R3-CT4 4 (isolated) R3-DC16A Analog 16 ch. 16 R5-NC1 with Clamp-on R3-CT4A R3-DC32A CC-Link Current Sensor R5T-CTB1 1 POWER MODULES Open Collector Output 32 Analog 32 ch. 224 mm / 8.8 in. (8-position base) 4 (isolated) R3-DC64A R5-NC2 R3-CT4B R5T-CTB2 2 Model Rating AC Current Input R3-CT4C R3-DC16B 64 T-Link with Clamp-on R5-NF1 R5-PSR 24Vdc Triac Output 16 R5T-PT1 1 BASE Current Sensor R3-CT8A AC Voltage R5-PSK 100–120Vac 8 (isolated) 120 mm R3-CT8B 231 mm / 9.1 in. (8 I/O modules) Input R5T-PT2 2 4.7 in. R3-CT8C BCD CODE MODULES R5-PSL 200–240Vac Totalized Zero-phase R5-PA2 R5T-PA2 2 R3-CZ4 4 (isolated) I/O Model CH Pulse Input Current Input 90 mm BCD Code Input R3-BA32A 32 BASE BASES AC Voltage Input R3-PT4 4 (isolated) 3.5 in. BCD Code Output R3-BC32A 32 Model Capacity AC Power Input R3-WT4 4 (isolated) ANALOG INPUT MODULES R5-BS04 4 I/O modules AC Power Input R3-WT4A POWER MODULES R5-BS05* 5 I/O modules with Clamp-on 4 (isolated) WITH RE-TRANSMITTED OUTPUT Current Sensor R3-WT4B Model Rating R5-BS08 8 I/O modules Input 130 mm R3-PS1 20V 750mA Model CH 9 I/O modules 5.1 in. Multi Power Input R3-WT1 1 system 90 mm R5-BS09* R3-PS3 20V 2.0A (double width) Thermocouple Input R5-TS1A 1 16 I/O modules Multi Power Input 3.5 in. R5-BS16 R3-WT1A with Clamp-on 1 system RTD Input R5-RS1A 1 R5-EX1 Extender Power Module Current Sensor R3-WT1B BASES Base DC Voltage Input R5-SV1A 1 Pulse Input R3-PA4 4 (isolated) Model Network *Single Network Module DC Current Input R5-SS1A 1 R3-PA4A R3-BS 2 to 16 Positions 4 (isolated) Totalized Pulse R3-PA4B R3-BSW 4 to 16 Positions, free I/O address 4-20mA Input POWER MODULE(S) Input with Excitation R5-DS1A 1 I/O MODULES R3-PA16 16 (isolated) POWER MODULE(S) I/O MODULES Potentiometer Input 1 NETWORK MODULE(S) Encoder Input R3-PA2 2 (isolated) NETWORK MODULE(S) R5-MS1A

Input Network

DC4-20mA Mains 120/240 VAC Re-Transmitted Output UPS 24 VDC

M3 screw terminal block is used for Network Module and Power Supply One I/O module plus one Network Module The slanted I/O terminals are easily Re-Transmitted 4 to 20 mAdc output is Add another power module for a backup I/O modules. The removable terminal Module in one housing. with power supply is the minimum unit: accessible even with high-density wiring. optional for local monitoring or recording power source. block is convenient for maintenance. Space-saving and economical solution.

36

37 Remote I/O Remote I/O R3 Series Multi-channel, Mixed Signal Remote I/O R5 Series Compact, Mixed Signal Remote I/O

Wide selection of I/O modules and network modules Free combination of I/O modules, network modules and power modules. • Great flexibilities in number and type of I/O signals: DC current/voltage, temperature, strain gauge, AC current/voltage, AC power, etc. • Single analog module can handle fully-isolated 2 points. • Hot-swappable I/O modules and power supplies • Hot-swappable I/O modules • Dual redundant communication networks • Dual redundant communication networks and power supplies • 1500 Vac isolation • Space-saving DIN terminal block or heavy-duty screw terminal block selectable for I/O • I/O modules with connector terminal available • 1500 Vac isolation

ANALOG INPUT MODULES ANALOG OUTPUT MODULES ANALOG INPUT MODULES ANALOG OUTPUT MODULES Input Model CH Output Model CH Model Model Input CH Output CH R3-TS4 4 (isolated) R3-YV4 4 (isolated) Euro TerminalScrew Terminal Euro TerminalScrew Terminal Thermocouple DC Voltage Output Input R3-TS8 8 (isolated) R3-YV8 8 (isolated) Thermocouple R5-TS1 R5T-TS1 1 DC Voltage R5-YV1 R5T-YV1 1 4 (isolated) DC Current Output R3-YS4 4 (isolated) R3-RS4 Input R5-TS2 R5T-TS2 2 Output R5-YV2 R5T-YV2 2 RTD Input R3-RS8 8 (isolated) Pulse Output R3-PC16A 16 R5-RS1 R5T-RS1 1 1 R3-RS8A 8 (isolated) 4-20mA R5-YS1 R5T-YS1 Output R3-SV4 ALARM MODULES R5-RS2 R5T-RS2 2 R5-YS2 R5T-YS2 2 R3-SV4B 4 (isolated) RTD Input Input Model CH R5-RSA1 1 R3-SV4C Totalized Pulse 2 Thermocouple Input R3-AT4 4 Output R5-PC2 R5T-PC2 R3-SV8 R5-RSA2 2 DC Voltage RTD Input R3-AR4 4 Input R3-SV8B 8 (isolated) R5T-SV1 R3-SV8C R3-AV4 4 R5-SV1 1 DC Voltage Input DC Voltage R3-SV8N 8 (non-isolated) R3-AV8 8 Input R5-SV2 R5T-SV2 2 DISCRETE MODULES R3-SV16N 16 (non-isolated) R3-AS4 4 Model DC Current Input R5-SS1 R5T-SS1 1 I/O CH DC Millivolt R3-SV4A 4 (isolated) R3-AS8 8 DC Current Euro TerminalScrew Terminal NETWORK MODULES Input Input R3-SV8A 8 (isolated) 4-20mA Input R5-SS2 R5T-SS2 2 R3-AD4 4 NETWORK MODULES Di 4 Points Model Capacity Model Capacity R3-SS4 4 (isolated) with Excitation Input R5-DA4 R5T-DA4 4 4-20mA Input R5-DS1 R5T-DS1 1 Model Capacity R3-NE1 Modbus/TCP (Ethernet) R3-NM1 Modbus DC Current R3-SS8 8 (isolated) with Excitation Input R5-DS2 R5T-DS2 2 R3-SS8N 8 (non-isolated) DISCRETE MODULES Modbus/TCP (Ethernet) Di 16 Points R5-DA16 R3-ND1 Analog 16 ch. R3-NP1 PROFIBUS-DP R5-NE1 16 R3-SS16N 16 (non-isolated) Potentiometer R5-MS1 1 Input (Connector) I/O Model CH Modbus R3-ND2 DeviceNet Analog 32 ch. R3-NL1 R5-NM1 Input ONWORKS R3-DS4 Dry Contact Input R3-DA16 16 R5-MS2 2 L 4-20mA Input 4 (isolated) Analog 16 ch. Do 4 Points Analog 64 ch. R3-DS4A R3-DA16A R5-ND1 R5-DC4 R5T-DC4 4 R3-ND3 R3-NL2 with Excitation 16 DeviceNet R5T-CT1 1 Output 8 (non-isolated) Dry Contact Input T-Link R3-DS8N R3-DA32A 32 R5-ND2 Analog 32 ch. CT Input R3-NC1 Ver. 1; Analog 16 ch. R3-NF1 with External Exc. 2 Potentiometer R3-MS4 4 (isolated) R3-DA64A R5T-CT2 64 R5-NP1 Analog 16 ch. Do 16 Points R5-DC16 16 CC-Link Ver. 1; Analog 32 ch. Input 8 (isolated) (Connector) R3-NC2 R3-MS8 R3-DA16B PROFIBUS-DP R5T-CTA1 1 Output AC Contact Input 16 Analog 32 ch. Ver.2 Strain Gauge Input R3-LC2 2 (isolated) R3-DC16 R5-NP2 R3-NC3 Relay Output 16 AC Current Input R5T-CTA2 2 CT Input R3-CT4 4 (isolated) R3-DC16A Analog 16 ch. 16 R5-NC1 with Clamp-on R3-CT4A R3-DC32A CC-Link Current Sensor R5T-CTB1 1 POWER MODULES Open Collector Output 32 Analog 32 ch. 224 mm / 8.8 in. (8-position base) 4 (isolated) R3-DC64A R5-NC2 R3-CT4B R5T-CTB2 2 Model Rating AC Current Input R3-CT4C R3-DC16B 64 T-Link with Clamp-on R5-NF1 R5-PSR 24Vdc Triac Output 16 R5T-PT1 1 BASE Current Sensor R3-CT8A AC Voltage R5-PSK 100–120Vac 8 (isolated) 120 mm R3-CT8B 231 mm / 9.1 in. (8 I/O modules) Input R5T-PT2 2 4.7 in. R3-CT8C BCD CODE MODULES R5-PSL 200–240Vac Totalized Zero-phase R5-PA2 R5T-PA2 2 R3-CZ4 4 (isolated) I/O Model CH Pulse Input Current Input 90 mm BCD Code Input R3-BA32A 32 BASE BASES AC Voltage Input R3-PT4 4 (isolated) 3.5 in. BCD Code Output R3-BC32A 32 Model Capacity AC Power Input R3-WT4 4 (isolated) ANALOG INPUT MODULES R5-BS04 4 I/O modules AC Power Input R3-WT4A POWER MODULES R5-BS05* 5 I/O modules with Clamp-on 4 (isolated) WITH RE-TRANSMITTED OUTPUT Current Sensor R3-WT4B Model Rating R5-BS08 8 I/O modules Input 130 mm R3-PS1 20V 750mA Model CH 9 I/O modules 5.1 in. Multi Power Input R3-WT1 1 system 90 mm R5-BS09* R3-PS3 20V 2.0A (double width) Thermocouple Input R5-TS1A 1 16 I/O modules Multi Power Input 3.5 in. R5-BS16 R3-WT1A with Clamp-on 1 system RTD Input R5-RS1A 1 R5-EX1 Extender Power Module Current Sensor R3-WT1B BASES Base DC Voltage Input R5-SV1A 1 Pulse Input R3-PA4 4 (isolated) Model Network *Single Network Module DC Current Input R5-SS1A 1 R3-PA4A R3-BS 2 to 16 Positions 4 (isolated) Totalized Pulse R3-PA4B R3-BSW 4 to 16 Positions, free I/O address 4-20mA Input POWER MODULE(S) Input with Excitation R5-DS1A 1 I/O MODULES R3-PA16 16 (isolated) POWER MODULE(S) I/O MODULES Potentiometer Input 1 NETWORK MODULE(S) Encoder Input R3-PA2 2 (isolated) NETWORK MODULE(S) R5-MS1A

Input Network

DC4-20mA Mains 120/240 VAC Re-Transmitted Output UPS 24 VDC

M3 screw terminal block is used for Network Module and Power Supply One I/O module plus one Network Module The slanted I/O terminals are easily Re-Transmitted 4 to 20 mAdc output is Add another power module for a backup I/O modules. The removable terminal Module in one housing. with power supply is the minimum unit: accessible even with high-density wiring. optional for local monitoring or recording power source. block is convenient for maintenance. Space-saving and economical solution.

36

37 Remote I/O R7 Series Compact Remote I/O PC Recorder

Economical all-in-one module for Modbus, CC-Link, DeviceNet, Remote Data Acquisition Hardware and Software LONWORKS and MECHATROLINK • Palm-top size compact module can handle 4 analog input / 2 analog output or 8 /16 discrete signals. PC Recorder Series • 8 or 16 discrete input/output module can be attached to the base module. Analog and discrete signals can be mixed. • Simple setting Log, Trend, Analyze and Profile Process • 1500 Vac isolation Signals with Your PC Data Collection by PC Recorder Software RS-485/RS-232C Communication Port Modbus RTU Network High Speed Sampling 50 ms / 8 ch External Trigger Input Remote Limit Alarming

M-System’s R1M/R2M series is a high performance line of analog and discrete I/O modules. These modules feature individual Extension module 1500 Vac isolation for analog modules channel configuration of input types and ranges. Field I/O connects directly to the R1M modules and data is transmitted via the Modbus RTU protocol over an RS-485 network. Additionally, the R1M/R2M provides an RS-232C port for portable host communica- tions to a PC. The R1M/R2M series is designed for remote I/O and laboratory data acquisition applications. Applications include tank level monitoring, flow monitoring, temperature profiling, discrete ON/OFF control and data logging. The Modbus RTU protocol enables interfacing with popular HMI and SCADA software packages. The R1M/R2M includes PC recorder software that easily replaces expensive traditional chart recorders. The PC recorder software is 8 or 16 discrete input or output module can be attached to Fully isolated between I/O, network and power input. fully featured enabling the logging, trending acquisition and analysis of application data. R1M/R2M hardware combined with PC the base module. Channel-to-channel isolation is also provided. Analog and discrete signals can be mixed by combining a Recorder software provides a low cost industrial grade data acquisition system. discrete I/O module with an analog module.

BASE MODULE Network Modbus DeviceNet CC-Link LONWORKS MECHATROLINK

NEW R1M-P4 Dry contact input, 16 points R7M-DA16 R7D-DA16 R7C-DA16 R7L-DA16 R7ML-DA16 NEW NPN transistor output, 16 points R7M-DC16A R7D-DC16A R7C-DC16A R7L-DC16A R7ML-DC16A NEW PNP transistor output, 16 points R7M-DC16B R7D-DC16B R7C-DC16B R7L-DC16B R7ML-DC16B NEW Model RZUS-U9 USB Bus-powered R1M Series RS-485 I/O Modules Dry contact input, 8 points & NPN transistor output, 8 points ------R7L-DAC16 ---- 12-point Universal Input Module R1M-GH2 16-point DC/TC inputs • 5 V (approx. 0.25 A) powered through the USB cable DC voltage / current input, 4 points R7M-SV4 R7D-SV4 R7C-SV4 R7L-SV4 NEW R7ML-SV4 NEW R1M-J3 8-point RTD/POT inputs • 12-point universal inputs independently configurable Thermocouple input, 4 points R7M-TS4 R7D-TS4 R7C-TS4 R7L-TS4 NEW R7ML-TS4 NEW R1M-A1 32-point dry contact input for each input RTD input, 4 poins R7M-RS4 R7D-RS4 R7C-RS4 R7L-RS4 NEW R7ML-RS4 NEW R1M-D1 32-point open collector output • Supports 13 TC types, 12 RTD types, potentiometer R1M-P4 Totalized pulse input and ±12 Vdc inputs DC voltage output, 2 points R7M-YV2 R7D-YV2 R7C-YV2 R7L-YV2 NEW R7ML-YV2 NEW R1M-GH2 R1M-J3 • Easily expandable via RS-485 R1M-A1 R1M-D1 DC voltage output, 2 points (external power supply) ---- R7D-YV2A ------DC current output, 2 points R7M-YS2 R7D-YS2 R7C-YS2 R7L-YS2 NEW R7ML-YS2 NEW DC current output, 2 points (external power supply) ---- R7D-YS2A ------EXTENSION MODULE Network Modbus DeviceNet CC-Link LONWORKS MECHATROLINK Dry contact input, 8 points R7M-EA8 R7D-EA8 R7C-EA8 R7C-EA8 NEW R7ML-EA8 NEW Dry contact input, 16 points R7M-EA16 R7D-EA16 R7C-EA16 R7C-EA16 NEW R7ML-EA16 NEW NPN transistor output, 8 points R7M-EC8A R7D-EC8A R7C-EC8A R7C-EC8A NEW R7ML-EC8A NEW NPN transistor output, 16 points R7M-EC16A R7D-EC16A R7C-EC16A R7C-EC16A NEW R7ML-EC16A NEW Model R1MS RS-485 Fully Isolated R2M Series RS-232 Modules Model RZMS-U9 RS-485 Isolated PNP transistor output, 8 points R7M-EC8B R7D-EC8B R7C-EC8B R7C-EC8B NEW R7ML-EC8B NEW 8-point DC/TC Input Module R2M-2G3 8-point DC inputs 12-point Universal Input Module PNP transistor output, 16 points R7M-EC16B R7D-EC16B R7C-EC16B R7C-EC16B NEW R7ML-EC16B NEW R2M-2H3 8-point TC inputs

38 39 Remote I/O R7 Series Compact Remote I/O PC Recorder

Economical all-in-one module for Modbus, CC-Link, DeviceNet, Remote Data Acquisition Hardware and Software LONWORKS and MECHATROLINK • Palm-top size compact module can handle 4 analog input / 2 analog output or 8 /16 discrete signals. PC Recorder Series • 8 or 16 discrete input/output module can be attached to the base module. Analog and discrete signals can be mixed. • Simple setting Log, Trend, Analyze and Profile Process • 1500 Vac isolation Signals with Your PC Data Collection by PC Recorder Software RS-485/RS-232C Communication Port Modbus RTU Network High Speed Sampling 50 ms / 8 ch External Trigger Input Remote Limit Alarming

M-System’s R1M/R2M series is a high performance line of analog and discrete I/O modules. These modules feature individual Extension module 1500 Vac isolation for analog modules channel configuration of input types and ranges. Field I/O connects directly to the R1M modules and data is transmitted via the Modbus RTU protocol over an RS-485 network. Additionally, the R1M/R2M provides an RS-232C port for portable host communica- tions to a PC. The R1M/R2M series is designed for remote I/O and laboratory data acquisition applications. Applications include tank level monitoring, flow monitoring, temperature profiling, discrete ON/OFF control and data logging. The Modbus RTU protocol enables interfacing with popular HMI and SCADA software packages. The R1M/R2M includes PC recorder software that easily replaces expensive traditional chart recorders. The PC recorder software is 8 or 16 discrete input or output module can be attached to Fully isolated between I/O, network and power input. fully featured enabling the logging, trending acquisition and analysis of application data. R1M/R2M hardware combined with PC the base module. Channel-to-channel isolation is also provided. Analog and discrete signals can be mixed by combining a Recorder software provides a low cost industrial grade data acquisition system. discrete I/O module with an analog module.

BASE MODULE Network Modbus DeviceNet CC-Link LONWORKS MECHATROLINK

NEW R1M-P4 Dry contact input, 16 points R7M-DA16 R7D-DA16 R7C-DA16 R7L-DA16 R7ML-DA16 NEW NPN transistor output, 16 points R7M-DC16A R7D-DC16A R7C-DC16A R7L-DC16A R7ML-DC16A NEW PNP transistor output, 16 points R7M-DC16B R7D-DC16B R7C-DC16B R7L-DC16B R7ML-DC16B NEW Model RZUS-U9 USB Bus-powered R1M Series RS-485 I/O Modules Dry contact input, 8 points & NPN transistor output, 8 points ------R7L-DAC16 ---- 12-point Universal Input Module R1M-GH2 16-point DC/TC inputs • 5 V (approx. 0.25 A) powered through the USB cable DC voltage / current input, 4 points R7M-SV4 R7D-SV4 R7C-SV4 R7L-SV4 NEW R7ML-SV4 NEW R1M-J3 8-point RTD/POT inputs • 12-point universal inputs independently configurable Thermocouple input, 4 points R7M-TS4 R7D-TS4 R7C-TS4 R7L-TS4 NEW R7ML-TS4 NEW R1M-A1 32-point dry contact input for each input RTD input, 4 poins R7M-RS4 R7D-RS4 R7C-RS4 R7L-RS4 NEW R7ML-RS4 NEW R1M-D1 32-point open collector output • Supports 13 TC types, 12 RTD types, potentiometer R1M-P4 Totalized pulse input and ±12 Vdc inputs DC voltage output, 2 points R7M-YV2 R7D-YV2 R7C-YV2 R7L-YV2 NEW R7ML-YV2 NEW R1M-GH2 R1M-J3 • Easily expandable via RS-485 R1M-A1 R1M-D1 DC voltage output, 2 points (external power supply) ---- R7D-YV2A ------DC current output, 2 points R7M-YS2 R7D-YS2 R7C-YS2 R7L-YS2 NEW R7ML-YS2 NEW DC current output, 2 points (external power supply) ---- R7D-YS2A ------EXTENSION MODULE Network Modbus DeviceNet CC-Link LONWORKS MECHATROLINK Dry contact input, 8 points R7M-EA8 R7D-EA8 R7C-EA8 R7C-EA8 NEW R7ML-EA8 NEW Dry contact input, 16 points R7M-EA16 R7D-EA16 R7C-EA16 R7C-EA16 NEW R7ML-EA16 NEW NPN transistor output, 8 points R7M-EC8A R7D-EC8A R7C-EC8A R7C-EC8A NEW R7ML-EC8A NEW NPN transistor output, 16 points R7M-EC16A R7D-EC16A R7C-EC16A R7C-EC16A NEW R7ML-EC16A NEW Model R1MS RS-485 Fully Isolated R2M Series RS-232 Modules Model RZMS-U9 RS-485 Isolated PNP transistor output, 8 points R7M-EC8B R7D-EC8B R7C-EC8B R7C-EC8B NEW R7ML-EC8B NEW 8-point DC/TC Input Module R2M-2G3 8-point DC inputs 12-point Universal Input Module PNP transistor output, 16 points R7M-EC16B R7D-EC16B R7C-EC16B R7C-EC16B NEW R7ML-EC16B NEW R2M-2H3 8-point TC inputs

38 39 PC Recorder MSRPAC

Remote Data Acquisition Hardware and Software MSRPAC PC Recorder Software Package SYSTEM CONFIGURATION EXAMPLES MSR128LV / MSR128LS - PC Recorder-Light Minimum Configuration Expanded System via Modbus RTU Expanded System via Ethernet • Ideal for basic logging and trending purposes MSRPAC MSRPAC MSRPAC • Maximum sampling rate of 50 ms for 8 channels, 500 ms to PC Recorder Software PC Recorder Software PC Recorder Software 1 minute for the total of 120 channels PC PC PC The MSR128-Light is designed to operate on a PC of relatively low performance, even a Windows 98 PC, though certain functions of the MSR128 which require the PC’s high RS-232C* RS-232C* performance, are not available. RS-485 / Modbus RTU Ethernet The data used for the recorder is saved in CSV format allowing easy export to other Windows programs such as Microsoft Excel. R1M, R1MS, R2M or RZMSR1M-D1 R1M-A1 R1M-GH2 Two models are available to run on low resolution screens. R3 Series *USB port is usable by using an adaptor. *USB port is usable by using an adaptor. MSR128LV for VGA (Screen area: 640 x 480 pixels) MSR128LS for SVGA (Screen area: 800 x 600 pixels)

Expanded System via Modbus RTU (R7 + MSR) Expanded System via Ethernet (73VR + R7 + MSR) MSR128 - Full Featured PC Recorder Software • Ideal for logging, trending and analyzing continuous process and batch applications. PC MSRPAC PC MSRPAC • Up to 128 channels can be monitored simultaneously. PC Recorder Software PC Recorder Software

• Maximum sampling rate of 500 ms for 128 channels. Ethernet • High speed sampling 100 ms with R3 series TCP/IP module.

• Four network R1M modules can be polled with remote limit alarming. RS-232/RS-485 Converter R2K-1 Paperless Recorder The MSR128 works with all PC Recorder modules. The (Models: 73VR1100) MSR128 software polls data from the input module, plots RS-485 the value on the screen and stores it to the PC’s hard drive. Paperless Recorder Paperless Recorder The data is polled, plotted and stored at a maximum rate (Models: 73VR3100) (Models: 73VR2100) RS-485 of 500 ms for 128 channels. Historical trends can be recalled, edited and used to be printed as hard copies or R7M R7M to be exported to spreadsheets for further analysis. R7M R7M R7M Data can be exported in CSV format to popular spreadsheet software packages such as Microsoft Excel. Data can be directly imported allowing the user to take full Expanded System via Modbus RTU (53U + MSR) Expanded System via Ethernet (53U + MSR) advantage of spreadsheet software features.

PC MSRPAC PC MSRPAC PC Recorder Software PC Recorder Software

Ethernet

RS-232/RS-485 Converter Communication Adaptor R2K-1 72EM2-M4

RS-485 RS-485

Multi Power Monitor 53U 53U Multi Power Monitor 53U 53U (Model: 53U) (Model: 53U)

40

41 PC Recorder MSRPAC

Remote Data Acquisition Hardware and Software MSRPAC PC Recorder Software Package SYSTEM CONFIGURATION EXAMPLES MSR128LV / MSR128LS - PC Recorder-Light Minimum Configuration Expanded System via Modbus RTU Expanded System via Ethernet • Ideal for basic logging and trending purposes MSRPAC MSRPAC MSRPAC • Maximum sampling rate of 50 ms for 8 channels, 500 ms to PC Recorder Software PC Recorder Software PC Recorder Software 1 minute for the total of 120 channels PC PC PC The MSR128-Light is designed to operate on a PC of relatively low performance, even a Windows 98 PC, though certain functions of the MSR128 which require the PC’s high RS-232C* RS-232C* performance, are not available. RS-485 / Modbus RTU Ethernet The data used for the recorder is saved in CSV format allowing easy export to other Windows programs such as Microsoft Excel. R1M, R1MS, R2M or RZMSR1M-D1 R1M-A1 R1M-GH2 Two models are available to run on low resolution screens. R3 Series *USB port is usable by using an adaptor. *USB port is usable by using an adaptor. MSR128LV for VGA (Screen area: 640 x 480 pixels) MSR128LS for SVGA (Screen area: 800 x 600 pixels)

Expanded System via Modbus RTU (R7 + MSR) Expanded System via Ethernet (73VR + R7 + MSR) MSR128 - Full Featured PC Recorder Software • Ideal for logging, trending and analyzing continuous process and batch applications. PC MSRPAC PC MSRPAC • Up to 128 channels can be monitored simultaneously. PC Recorder Software PC Recorder Software

• Maximum sampling rate of 500 ms for 128 channels. Ethernet • High speed sampling 100 ms with R3 series TCP/IP module.

• Four network R1M modules can be polled with remote limit alarming. RS-232/RS-485 Converter R2K-1 Paperless Recorder The MSR128 works with all PC Recorder modules. The (Models: 73VR1100) MSR128 software polls data from the input module, plots RS-485 the value on the screen and stores it to the PC’s hard drive. Paperless Recorder Paperless Recorder The data is polled, plotted and stored at a maximum rate (Models: 73VR3100) (Models: 73VR2100) RS-485 of 500 ms for 128 channels. Historical trends can be recalled, edited and used to be printed as hard copies or R7M R7M to be exported to spreadsheets for further analysis. R7M R7M R7M Data can be exported in CSV format to popular spreadsheet software packages such as Microsoft Excel. Data can be directly imported allowing the user to take full Expanded System via Modbus RTU (53U + MSR) Expanded System via Ethernet (53U + MSR) advantage of spreadsheet software features.

PC MSRPAC PC MSRPAC PC Recorder Software PC Recorder Software

Ethernet

RS-232/RS-485 Converter Communication Adaptor R2K-1 72EM2-M4

RS-485 RS-485

Multi Power Monitor 53U 53U Multi Power Monitor 53U 53U (Model: 53U) (Model: 53U)

40

41 PC Recorder MSRpro

MSRpro Client/Server System High Performance PC Recorder SYSTEM CONFIGURATION EXAMPLES Max. 2048 points Expanded System via Ethernet (73VR + R7 + MSR) High speed 100 msec. mode up to 256 points

Active trend view to compare in real time past and present data overlapped on each other MSRpro-Client / MSRpro-Server Analyzer MSRpro-Builder Arithmetic and logic functions, including the ones performed between channels Ethernet Alarm history and data search functions Switching Hub Ethernet The MSRpro is a ‘paperless pen-type’ recording system for PC-based data acquisition and analysis. By communicating with I/O modules that have a LAN card communication interface, the MSRpro reads in input signals and stores them in a hard disk as digital RS-485 data. By sharing viewing and storing tasks by ‘Client’ and ‘Server,’ the MSRpro realizes the recording and operating functions of large number of input signals in high speed. Communication R3 Series R5 Series Paperless Recorder Paperless Recorder Adaptor R7M R7M R7M M-System’s remote I/O modules, R3 Series, offers a wide variety of input signals including DC and AC signals, temperature, (Models: 73VR3100) (Models: 73VR2100) 72EM2-M4 potentiometer, strain gauge and others. The MSRpro is a suite of three programs: Expanded System via Ethernet (53U + MSR) R3 Series I/O Personal Computer Collects and stores input measurement data MSRpro-Server MSRpro-Client/ MSRpro-Server Analyzer and executes arithmetic computation to it. Sample (Data Views) Trend Graph MSRpro-Client /Analyzer Analog Input Store Stored Data MSRpro-Server MSRpro-Client/Analyzer Used to view, analyze and print measurement data. Compute Overview Contact Input Alarm History MSRpro-Builder Contact Output Trend Retrieval Ethernet MSRpro-Builder Creates and modifies configurations for either program.

Communication RS-485 Trend View Overview Active Trend Graphic Adaptor 72EM2-M4

Multi Power Monitor 53U 53U (Model: 53U)

Power Monitoring System

MSRpro-Client / MAX.4 (ClientPC) Server PC Analyzer

Ethernet Client PC MSRpro-Server MSRpro-Builder MSRpro-Client / Analyzer MSRpro-Server MSRpro-Builder Ethernet

Communication Communication Adaptor Adaptor Modbus/TCP Ethernet Communication 72EM2-M4 72EM2-M4 Adaptor RS-485 Modbus RTU 72EM2-M4 RS-485 RS-485

R3 Series

R1M RZUS-U9 Multi Power Monitor 53U R7M R7M (Model: 53U) MAX.8 stations (incl.72EM2)

42 43 PC Recorder MSRpro

MSRpro Client/Server System High Performance PC Recorder SYSTEM CONFIGURATION EXAMPLES Max. 2048 points Expanded System via Ethernet (73VR + R7 + MSR) High speed 100 msec. mode up to 256 points

Active trend view to compare in real time past and present data overlapped on each other MSRpro-Client / MSRpro-Server Analyzer MSRpro-Builder Arithmetic and logic functions, including the ones performed between channels Ethernet Alarm history and data search functions Switching Hub Ethernet The MSRpro is a ‘paperless pen-type’ recording system for PC-based data acquisition and analysis. By communicating with I/O modules that have a LAN card communication interface, the MSRpro reads in input signals and stores them in a hard disk as digital RS-485 data. By sharing viewing and storing tasks by ‘Client’ and ‘Server,’ the MSRpro realizes the recording and operating functions of large number of input signals in high speed. Communication R3 Series R5 Series Paperless Recorder Paperless Recorder Adaptor R7M R7M R7M M-System’s remote I/O modules, R3 Series, offers a wide variety of input signals including DC and AC signals, temperature, (Models: 73VR3100) (Models: 73VR2100) 72EM2-M4 potentiometer, strain gauge and others. The MSRpro is a suite of three programs: Expanded System via Ethernet (53U + MSR) R3 Series I/O Personal Computer Collects and stores input measurement data MSRpro-Server MSRpro-Client/ MSRpro-Server Analyzer and executes arithmetic computation to it. Sample (Data Views) Trend Graph MSRpro-Client /Analyzer Analog Input Store Stored Data MSRpro-Server MSRpro-Client/Analyzer Used to view, analyze and print measurement data. Compute Overview Contact Input Alarm History MSRpro-Builder Contact Output Trend Retrieval Ethernet MSRpro-Builder Creates and modifies configurations for either program.

Communication RS-485 Trend View Overview Active Trend Graphic Adaptor 72EM2-M4

Multi Power Monitor 53U 53U (Model: 53U)

Power Monitoring System

MSRpro-Client / MAX.4 (ClientPC) Server PC Analyzer

Ethernet Client PC MSRpro-Server MSRpro-Builder MSRpro-Client / Analyzer MSRpro-Server MSRpro-Builder Ethernet

Communication Communication Adaptor Adaptor Modbus/TCP Ethernet Communication 72EM2-M4 72EM2-M4 Adaptor RS-485 Modbus RTU 72EM2-M4 RS-485 RS-485

R3 Series

R1M RZUS-U9 Multi Power Monitor 53U R7M R7M (Model: 53U) MAX.8 stations (incl.72EM2)

42 43 73VR Paperless Recorder

Replace paper chart recorders and save cost of supplies and maintenance. 73VR1100 connects to remote I/O Environmentally friendly data recording solution – no chart paper, pens and cartridges. 73VR Series offers 3 types to select in many applications. Designed to utilize a wide variety of M-System's remote I/O devices. Versatile data recording. • Best suited to record data transmitted from remote I/O located remotely in the field, or inside an instrumentation or control cabinet. • Instead of using expensive sensor cables, reduce wiring runs by using open field networks through remote I/O. • I/O separated 73VR1100 provides the installation flexibility which fits in the tight space of a control panel or machinery chassis.

73VR1100 R3 Series

R7 Series

MULTICHANNEL REMOTE DATA ACQUISITION REDUCE WIRING COST

73VR1100

Up to 128 points 73VR1100

Touch panel operation. Max. 500 meters Selectable number of pens to display. Modbus RS-485 5.5-inch TFT color display with backlight.

In addition to the conventional white chart color, Remote I/O Remote I/O blue-to-black gradating background color is selectable. Up to 15 remote I/O Sensor Sensor Sensor Sensor IP 65 front cover. Ethernet - Up to 2 stations

SPECIFICATIONS Trend View (horizontal) Trend View (perpendicular) Trend View (large digital display) Overview Number of input channels 64, 128 (Function pen points are included in the above figures.) Function pen points 32, 64 Storing rate (high speed mode) 100 msec. Storing rate (normal mode) 500 msec., 1, 2, 5, 10 seconds, 1minute, 10 minutes Input types Use R3 series I/O modules (DC voltage, DC current, Thermocouple, RTD, AC voltage, AC current, Encoder, Totalized pulse) Trigger input Max. 128 via remote I/O Alarm/Run output Alarm x 1, Run x1; Alarm also available via remote output modules Bargraph View (horizontal) Bargraph View (perpendicular) Alarm History View Overview (large digital display) Weight 1.7 kg (3.7 lbs) Display Display device 5.5-inch TFT LCD Display colors 256 Resolution 320 x 240 pixels Ethernet 10BASE-T / 100BASE-TX automatically switched; Conforms to IEEE802 (10BASE-T) or IEEE802.3 (100BASE-TX) Degree of protection IP65 (applicable to the front panel of with the cover closed when a single unit is mounted according to the specified panel cutout) CE marking Yes

44 45 73VR Paperless Recorder

Replace paper chart recorders and save cost of supplies and maintenance. 73VR1100 connects to remote I/O Environmentally friendly data recording solution – no chart paper, pens and cartridges. 73VR Series offers 3 types to select in many applications. Designed to utilize a wide variety of M-System's remote I/O devices. Versatile data recording. • Best suited to record data transmitted from remote I/O located remotely in the field, or inside an instrumentation or control cabinet. • Instead of using expensive sensor cables, reduce wiring runs by using open field networks through remote I/O. • I/O separated 73VR1100 provides the installation flexibility which fits in the tight space of a control panel or machinery chassis.

73VR1100 R3 Series

R7 Series

MULTICHANNEL REMOTE DATA ACQUISITION REDUCE WIRING COST

73VR1100

Up to 128 points 73VR1100

Touch panel operation. Max. 500 meters Selectable number of pens to display. Modbus RS-485 5.5-inch TFT color display with backlight.

In addition to the conventional white chart color, Remote I/O Remote I/O blue-to-black gradating background color is selectable. Up to 15 remote I/O Sensor Sensor Sensor Sensor IP 65 front cover. Ethernet - Up to 2 stations

SPECIFICATIONS Trend View (horizontal) Trend View (perpendicular) Trend View (large digital display) Overview Number of input channels 64, 128 (Function pen points are included in the above figures.) Function pen points 32, 64 Storing rate (high speed mode) 100 msec. Storing rate (normal mode) 500 msec., 1, 2, 5, 10 seconds, 1minute, 10 minutes Input types Use R3 series I/O modules (DC voltage, DC current, Thermocouple, RTD, AC voltage, AC current, Encoder, Totalized pulse) Trigger input Max. 128 via remote I/O Alarm/Run output Alarm x 1, Run x1; Alarm also available via remote output modules Bargraph View (horizontal) Bargraph View (perpendicular) Alarm History View Overview (large digital display) Weight 1.7 kg (3.7 lbs) Display Display device 5.5-inch TFT LCD Display colors 256 Resolution 320 x 240 pixels Ethernet 10BASE-T / 100BASE-TX automatically switched; Conforms to IEEE802 (10BASE-T) or IEEE802.3 (100BASE-TX) Degree of protection IP65 (applicable to the front panel of with the cover closed when a single unit is mounted according to the specified panel cutout) CE marking Yes

44 45 73VR Paperless Recorder

73VR2100 built-in universal input modules 73VR3100 selectable input modules Universal input – DC, Thermocouple, RTD Flexible I/O capability using the R3 series modules. Compatible with various open networks. • Independent input type and range selectable for each channel. • 100 msec. storing rate up to 6 point. • Up to 4 R3 Series I/O modules can be selected (Max. 64 inputs). • 2, 4, 6, 8, 10 or 12 points. • By replacing one of the I/O modules with Network Module for the R3 Series, the 73VR3100 can directly communicate to major • Real time trending and recording on the PC Recorder software PLC via DeviceNet, Modbus, Ethernet (Modbus/TCP), MSR via Ethernet. PROFIBUS-DP, LONWORKS and CC-Link. • 20 msec. storing rate with the combination of 8 analog and 8 discrete inputs. • Real time trending and recording on the PC Recorder software MSR via Ethernet.

5.5-inch TFT LCD Selectable I/O modules Network module touch panel screen (max. 4) QUICK SETUP INPUT TYPE DC VOLTAGE Input resistance: 900kΩ minimum Open network module installed, using 73VR3100 as (Excluding the case in which, with range setting other than Display & recording data input to a control system ±12V, ±6V or ±3V, a voltage exceeding± 1.3V is applied.) remote I/O with local display and recording function. Input range: ±60mV, ±125mV, ±250mV, ±500mV, ±1000mV, Recorder Operator Panel Operator Panel ± ± ± 3V, 6V, 12V PLC CPU DC CURRENT 4-20mA, use optional REM3-250 resistor module

THERMOCOUPLE Input range: (PR), K (CA), E (CRC), F (IC), T (CC), B (RH), R, S, PLC PLC C (WRe 5-26), N, U, L, P (Platinel II) Open Network Open Burnout sensing • Upscale: ≤130nA Network • Downscale: ≤220nA • No burnout: ≤10nA 73VR3100 RTD (3-wire) Input range: Pt 100 (JIS ’89), Pt 100 (JIS ’97, IEC), Pt 200, Pt 300, Pt 400, 73VR3100 Pt 500, Pt 1000, Pt 50Ω (JIS ’81), JPt 100 (JIS ’89), Ni 100, Isolator Intuitive “Help View” screen for easy user setup Ω ° Ni 120, Ni 508.4 , Ni-Fe 604, Cu 10 @25C Input Input Input Input Input Input Input Input and use. Allowable leadwire resistance: 20Ω per wire Input Input Input Input Input Input Burnout sensing • Upscale or Downscale:≤130nA

SPECIFICATIONS SPECIFICATIONS Number of input channels 4-64 Number of input channels 2, 4, 6, 8, 10 or 12 Function pen points 16, 64 Function pen points 12 Storing rate (high speed mode) 20 msec., 100 msec. Storing rate (high speed mode) 100 msec. Storing rate (normal mode) 500 msec., 1, 2, 5, 10 seconds, 1minute, 10 minutes Storing rate (normal mode) 500 msec., 1, 2, 5, 10 seconds, 1minute, 10 minutes Input types Use R3 series I/O modules Input types Universal input (DC mV and voltage, thermocouple, 3-wire RTD) (DC voltage, DC current, Thermocouple, RTD, AC voltage, AC current, Encoder, Totalized pulse, Di/o) Trigger input Dry contact x 1 Trigger input Max. 64 (varies by input modules used) Alarm/Run output Relay contact x 1 Alarm/Run output Max. 32 (varies by input modules used) Weight 2.4 kg (5.3 lbs) Weight 2.3 kg (5.1 lbs) except I/O modules Display Display device 5.5-inch TFT LCD Display Display device 5.5-inch TFT LCD Display colors 256 Display colors 256 Resolution 320 x 240 pixels Resolution 320 x 240 pixels Ethernet 10BASE-T / 100BASE-TX automatically switched; Ethernet 10BASE-T / 100BASE-TX automatically switched; Conforms to IEEE802 (10BASE-T) or IEEE802.3 (100BASE-TX) Conforms to IEEE802 (10BASE-T) or IEEE802.3 (100BASE-TX) Degree of protection IP65 (applicable to the front panel of with the cover closed when a single unit is Degree of protection IP65 (applicable to the front panel of with the cover closed when a single unit is mounted according to the specified panel cutout) mounted according to the specified panel cutout) CE marking Yes CE marking ----

46 47 73VR Paperless Recorder

73VR2100 built-in universal input modules 73VR3100 selectable input modules Universal input – DC, Thermocouple, RTD Flexible I/O capability using the R3 series modules. Compatible with various open networks. • Independent input type and range selectable for each channel. • 100 msec. storing rate up to 6 point. • Up to 4 R3 Series I/O modules can be selected (Max. 64 inputs). • 2, 4, 6, 8, 10 or 12 points. • By replacing one of the I/O modules with Network Module for the R3 Series, the 73VR3100 can directly communicate to major • Real time trending and recording on the PC Recorder software PLC via DeviceNet, Modbus, Ethernet (Modbus/TCP), MSR via Ethernet. PROFIBUS-DP, LONWORKS and CC-Link. • 20 msec. storing rate with the combination of 8 analog and 8 discrete inputs. • Real time trending and recording on the PC Recorder software MSR via Ethernet.

5.5-inch TFT LCD Selectable I/O modules Network module touch panel screen (max. 4) QUICK SETUP INPUT TYPE DC VOLTAGE Input resistance: 900kΩ minimum Open network module installed, using 73VR3100 as (Excluding the case in which, with range setting other than Display & recording data input to a control system ±12V, ±6V or ±3V, a voltage exceeding± 1.3V is applied.) remote I/O with local display and recording function. Input range: ±60mV, ±125mV, ±250mV, ±500mV, ±1000mV, Recorder Operator Panel Operator Panel ± ± ± 3V, 6V, 12V PLC CPU DC CURRENT 4-20mA, use optional REM3-250 resistor module

THERMOCOUPLE Input range: (PR), K (CA), E (CRC), F (IC), T (CC), B (RH), R, S, PLC PLC C (WRe 5-26), N, U, L, P (Platinel II) Open Network Open Burnout sensing • Upscale: ≤130nA Network • Downscale: ≤220nA • No burnout: ≤10nA 73VR3100 RTD (3-wire) Input range: Pt 100 (JIS ’89), Pt 100 (JIS ’97, IEC), Pt 200, Pt 300, Pt 400, 73VR3100 Pt 500, Pt 1000, Pt 50Ω (JIS ’81), JPt 100 (JIS ’89), Ni 100, Isolator Intuitive “Help View” screen for easy user setup Ω ° Ni 120, Ni 508.4 , Ni-Fe 604, Cu 10 @25C Input Input Input Input Input Input Input Input and use. Allowable leadwire resistance: 20Ω per wire Input Input Input Input Input Input Burnout sensing • Upscale or Downscale:≤130nA

SPECIFICATIONS SPECIFICATIONS Number of input channels 4-64 Number of input channels 2, 4, 6, 8, 10 or 12 Function pen points 16, 64 Function pen points 12 Storing rate (high speed mode) 20 msec., 100 msec. Storing rate (high speed mode) 100 msec. Storing rate (normal mode) 500 msec., 1, 2, 5, 10 seconds, 1minute, 10 minutes Storing rate (normal mode) 500 msec., 1, 2, 5, 10 seconds, 1minute, 10 minutes Input types Use R3 series I/O modules Input types Universal input (DC mV and voltage, thermocouple, 3-wire RTD) (DC voltage, DC current, Thermocouple, RTD, AC voltage, AC current, Encoder, Totalized pulse, Di/o) Trigger input Dry contact x 1 Trigger input Max. 64 (varies by input modules used) Alarm/Run output Relay contact x 1 Alarm/Run output Max. 32 (varies by input modules used) Weight 2.4 kg (5.3 lbs) Weight 2.3 kg (5.1 lbs) except I/O modules Display Display device 5.5-inch TFT LCD Display Display device 5.5-inch TFT LCD Display colors 256 Display colors 256 Resolution 320 x 240 pixels Resolution 320 x 240 pixels Ethernet 10BASE-T / 100BASE-TX automatically switched; Ethernet 10BASE-T / 100BASE-TX automatically switched; Conforms to IEEE802 (10BASE-T) or IEEE802.3 (100BASE-TX) Conforms to IEEE802 (10BASE-T) or IEEE802.3 (100BASE-TX) Degree of protection IP65 (applicable to the front panel of with the cover closed when a single unit is Degree of protection IP65 (applicable to the front panel of with the cover closed when a single unit is mounted according to the specified panel cutout) mounted according to the specified panel cutout) CE marking Yes CE marking ----

46 47 Bargraph Indicators Digital Panel Meters

Bargraph Indicator Digital Panel Meters, LED Display Type DC input 48NV Panel cut size 36 x 144 mm DC input, 4 1/2 digits 47LYV NEW • Red, Amber, Green, Blue Mounting direction Vertical / Horizontal DC input, 4 1/2 digits 47LV • Vertical or horizontal mounting Bargraph LED 101 segments (two), 100 mm Thermocouple input, 4 digits 47LT • Single/dual bargraphs Bar color Red, Amber, Green, Blue RTD input, 4 digits 47LR • IP 65 front panel cover Power input 100-240 Vac or 24 Vdc Potentiometer input, 4 digits 47LM CE marking Yes Strain gauge input, 4 1/2 digits 47LLC Future Plan AC current input, 4 1/2 digits 47LAC NEW PT input, 4 1/2 digits 47LPT NEW CT input, 4 1/2 digits 47LCT NEW • 1/8 DIN size • LED color selectable, Red, Orange, Green, Bluegreen, Blue, White • Field-selectable input range Bargraph Indicating Alarm • IP66 front panel DC input 48NAV Panel cut size 36 x 144 mm Transmitter output 48NAVA Digital Panel Meters, LCD Display Type Mounting direction Vertical / Horizontal 2-wire transmitter excitation 48NAVD Bargraph LED 101 segments, 100 mm DC input, 5 1/2 digits 47DV NEW Thermocouple input 48NAT Thermocouple input, 5 1/2 digits 47DT NEW RTD input 48NAR Bar color Red, Amber, Green, Blue, Multicolor (red/orange/green) RTD input, 5 1/2 digits 47DR NEW Potentiometer input 48NAM NEW Power input 100-240 Vac or 24 Vdc Potentiometer input, 5 1/2 digits 47DM • Red, Amber, Green, Blue or Multicolor LED (red/orange/green) Alarm trip option Dual or quad alarm • 1/8 DIN size • Vertical or horizontal mounting CE marking Yes • Red or Green LCD selectable (negative type LCD with LED backlight) • bargraph plus alarm output • Field-selectable input range • IP 65 front panel cover • IP66 front panel

4-digit LED Loop Powered Indicator 4-digit Loop Powered Indicator, Intrinsically safe 6DV-B Bargraph Indicating Alarm (with 4-digit digital meter) Explosion-proof - flameproof, Field-mount DC input 48NDV Panel cut size 36 x 144 mm 4-digit Loop Powered Indicator, Intrinsically safe 6DV Transmitter output 48NDVA Mounting direction Vertical • 4-20 mA input powered 2-wire transmitter excitation 48NDVD Bargraph LED 101 segments, 100 mm • No external power source required Thermocouple input 48NDT • Scaling & linearization selectable via the front control buttons RTD input 48NDR Bar color Red, Amber, Green, Blue, Multicolor (red/orange/green) Potentiometer input 48NDM Digital display digit 9999 • Red, Amber, Green, Blue or Multicolor LED 3 1/2 digit LED Loop Powered Indicator LED height 8 mm (red) (red/orange/green) 43 Series • Vertical mounting Power input 100-240 Vac or 24 Vdc • bargraph, digital indicator plus alarm output Alarm trip option Dual or quad alarm • 4-20 mA input powered • No external power source required • IP 65 front panel cover CE marking Yes

DIGITAL PANEL METER SPECIFICATIONS Model No. 47LV 47DV 6DV / 6DV-B 43AL BARGRAPH INDICATOR SPECIFICATIONS Panel cut size 96 x 48 mm, 1/8 DIN 96 x 48 mm, 1/8 DIN ---- 48 x 24 mm, 1/32 DIN Input type DC input Transmitter output 2-wire transmitter Thermocouple input RTD input Potentiometer input Display digit 19999 199999 9999 1999 excitation Display height 16 mm (.63") Main display: 14.2 mm (.56") 8 mm (.30") 10.16 mm (.40") Model No. 48NV ------Sub display: 5.5 mm (.22") 48NAV 48NAVA 48NAVD 48NAT 48NAR 48NAM Display color Red / Orange / Green / Main display: Red and Green Red Red 48NDV 48NDVA 48NDVD 48NDT 48NDR 48NDM Bluegreen / Blue / White Sub display: Yellow-green Input Specific range of Specific range of 4-20mAdc Thermocouples; 2- or 3-wire RTDs; Potentiometer; Input ±10 V, ±5 V, DC voltage: ±5 V, 1-5 V, ±20 V, ±200 V 4-20 mAdc 4-20 mAdc 0-50 mAdc or 0-50 mAdc or K, E, J, T, B, R, S, N Pt 100, Pt 50Ω, 100Ω – 10kΩ 0-5 V, 1-5 V, DC current: 0-20 mA, 4-20 mA, ±10 Vdc ±10 Vdc Ni 508.4 0-20 mA, 4-20 mA ±20 mA, ±200 mA Excitation ------24-28 Vdc @22mA ------supply option Power input 100-240 Vac or 24 Vdc Not required Not required Output options Alarm Transmitter output, Alarm, RS-485, Modbus-RTU ------Transmitter ----4-20 mA, 1-5 V and ------output option other specific range CE marking ---- Yes Yes of 0-20 mA or ±10V Safety approval ---- FM / ATEX UL

48 49 Bargraph Indicators Digital Panel Meters

Bargraph Indicator Digital Panel Meters, LED Display Type DC input 48NV Panel cut size 36 x 144 mm DC input, 4 1/2 digits 47LYV NEW • Red, Amber, Green, Blue Mounting direction Vertical / Horizontal DC input, 4 1/2 digits 47LV • Vertical or horizontal mounting Bargraph LED 101 segments (two), 100 mm Thermocouple input, 4 digits 47LT • Single/dual bargraphs Bar color Red, Amber, Green, Blue RTD input, 4 digits 47LR • IP 65 front panel cover Power input 100-240 Vac or 24 Vdc Potentiometer input, 4 digits 47LM CE marking Yes Strain gauge input, 4 1/2 digits 47LLC Future Plan AC current input, 4 1/2 digits 47LAC NEW PT input, 4 1/2 digits 47LPT NEW CT input, 4 1/2 digits 47LCT NEW • 1/8 DIN size • LED color selectable, Red, Orange, Green, Bluegreen, Blue, White • Field-selectable input range Bargraph Indicating Alarm • IP66 front panel DC input 48NAV Panel cut size 36 x 144 mm Transmitter output 48NAVA Digital Panel Meters, LCD Display Type Mounting direction Vertical / Horizontal 2-wire transmitter excitation 48NAVD Bargraph LED 101 segments, 100 mm DC input, 5 1/2 digits 47DV NEW Thermocouple input 48NAT Thermocouple input, 5 1/2 digits 47DT NEW RTD input 48NAR Bar color Red, Amber, Green, Blue, Multicolor (red/orange/green) RTD input, 5 1/2 digits 47DR NEW Potentiometer input 48NAM NEW Power input 100-240 Vac or 24 Vdc Potentiometer input, 5 1/2 digits 47DM • Red, Amber, Green, Blue or Multicolor LED (red/orange/green) Alarm trip option Dual or quad alarm • 1/8 DIN size • Vertical or horizontal mounting CE marking Yes • Red or Green LCD selectable (negative type LCD with LED backlight) • bargraph plus alarm output • Field-selectable input range • IP 65 front panel cover • IP66 front panel

4-digit LED Loop Powered Indicator 4-digit Loop Powered Indicator, Intrinsically safe 6DV-B Bargraph Indicating Alarm (with 4-digit digital meter) Explosion-proof - flameproof, Field-mount DC input 48NDV Panel cut size 36 x 144 mm 4-digit Loop Powered Indicator, Intrinsically safe 6DV Transmitter output 48NDVA Mounting direction Vertical • 4-20 mA input powered 2-wire transmitter excitation 48NDVD Bargraph LED 101 segments, 100 mm • No external power source required Thermocouple input 48NDT • Scaling & linearization selectable via the front control buttons RTD input 48NDR Bar color Red, Amber, Green, Blue, Multicolor (red/orange/green) Potentiometer input 48NDM Digital display digit 9999 • Red, Amber, Green, Blue or Multicolor LED 3 1/2 digit LED Loop Powered Indicator LED height 8 mm (red) (red/orange/green) 43 Series • Vertical mounting Power input 100-240 Vac or 24 Vdc • bargraph, digital indicator plus alarm output Alarm trip option Dual or quad alarm • 4-20 mA input powered • No external power source required • IP 65 front panel cover CE marking Yes

DIGITAL PANEL METER SPECIFICATIONS Model No. 47LV 47DV 6DV / 6DV-B 43AL BARGRAPH INDICATOR SPECIFICATIONS Panel cut size 96 x 48 mm, 1/8 DIN 96 x 48 mm, 1/8 DIN ---- 48 x 24 mm, 1/32 DIN Input type DC input Transmitter output 2-wire transmitter Thermocouple input RTD input Potentiometer input Display digit 19999 199999 9999 1999 excitation Display height 16 mm (.63") Main display: 14.2 mm (.56") 8 mm (.30") 10.16 mm (.40") Model No. 48NV ------Sub display: 5.5 mm (.22") 48NAV 48NAVA 48NAVD 48NAT 48NAR 48NAM Display color Red / Orange / Green / Main display: Red and Green Red Red 48NDV 48NDVA 48NDVD 48NDT 48NDR 48NDM Bluegreen / Blue / White Sub display: Yellow-green Input Specific range of Specific range of 4-20mAdc Thermocouples; 2- or 3-wire RTDs; Potentiometer; Input ±10 V, ±5 V, DC voltage: ±5 V, 1-5 V, ±20 V, ±200 V 4-20 mAdc 4-20 mAdc 0-50 mAdc or 0-50 mAdc or K, E, J, T, B, R, S, N Pt 100, Pt 50Ω, 100Ω – 10kΩ 0-5 V, 1-5 V, DC current: 0-20 mA, 4-20 mA, ±10 Vdc ±10 Vdc Ni 508.4 0-20 mA, 4-20 mA ±20 mA, ±200 mA Excitation ------24-28 Vdc @22mA ------supply option Power input 100-240 Vac or 24 Vdc Not required Not required Output options Alarm Transmitter output, Alarm, RS-485, Modbus-RTU ------Transmitter ----4-20 mA, 1-5 V and ------output option other specific range CE marking ---- Yes Yes of 0-20 mA or ±10V Safety approval ---- FM / ATEX UL

48 49 Lightning Surge Protectors

M-System Lightning Surge Protectors absorb only the lightning Model MAKF One-Port Surge Protector For Power Supply Use surges with no interruption of the instrumentation signal Designed to protect electronics equipment from induced lightning surges entering through power supply cables Protects sensor, signal and power lines Connected in parallel between the power and ground lines regardless of load current Can be removed and tested without Varistor discharge element has a high speed response without follow current disconnecting wires No interruption of power supply even when the head element is removed: easy maintenance and replacing Superior protection and selection across Degraded head element is automatically separated from the power lines to a wide range of applications including: prevent overheating, with a relay contact output to alert the failure status 4-20 mA & pulse signal Head-base connection is keyed so that only a head element of correct line Thermocouple voltage can be mounted RTD Surge Current Flow (cross section) Potentiometer Strain gauge Thermal Breaker (cross section) Connection Examples Lightning Surge Frequency generating devices Telemetering devices Single-phase / 2-wire connection M5 screw (spring loaded) RS-485 / RS-422 Breaker Operation Protected Device G Metal Oxide Ethernet, DeviceNet, PROFIBUS, LONWORKS The alarm output switch is turned on. Varistor (MOV) AC/DC Power supply lines (1 amp up to 30 amps) 3

When the low temperature-melting Cross-wiring solder is melted by an abnormal high Grounding temperature at the discharge element, Model MDPA-24 Lightning Surge Protector with Life Monitor 1 the lever mechanism is released by the Single-phase / 3-wire, force of spring to separate the three-phase / 3-wire connection discharge element from the circuit. Designed specifically for 4-20 mA and pulse signal Protected Device ALM Indicator LED G BAT Indicator LED line including 4-wire/2-wire transmitters. The green failure indicator turns to 2 black at the same time. LIFE IDENTICATION Battery powered life monitoring system includes CHK Check Button ALT BAT Replacement Cross-wiring a ‘Test’ button with indicators alerting panel No Need Ground Near Grounding inspectors of the surge protector’s ‘health.’ Immediately CLOSE UP Required Model SHSP 8-Port Ethernet Switch with Surge Protector MDP-24-1 MA-100 / MA-200 • 4-20 mA & pulse signals • 120 Vac / 240 Vac power supply lines Surge protector function for each port • UL listed • 2 amps • CE marking • Fuse provided for supplementar Protects Ethernet devices from surges entering through LAN cables protection Surge protector life monitor function with LED and contact output alarm • CE marking Data transfer rate can be fixed

MDM2A-24 MAA-100 / MAA-200 LAN PORT SPECIFICATIONS SURGE PROTECTOR PERFORMANCE • 4-20 mA & pulse signals MAAC-100 / MAAC-200 FRONT VIEW • Life monitor • 120 Vac / 240 Vac power supply lines Standards IEEE 802.3, IEEE 802.3u, IEEE 802.3x Compliant standard EN61000-4-5 level X LINK LED • Alarm output • 5 amps Number of ports 8; All ports support AUTO-MDIX* Between ports 1kV (combination waveform) 100M LED • CE marking • Life monitor Data transfer rate 10 Mbps (10 BASE-T), Port to G 10kV (combination waveform)** 100 Mbps (100 BASE-TX); FG (shield) to G 15kV (combination waveform)*** • Surge counter function Supports Auto-Negotiation Voltage protection level LAN Ports (x 8) • CE marking 10 BASE-T (STP cable, category 5) RJ45 Connector Cable 100 BASE-TX (STP cable, category 5e) Port to FG or G 160V min. MDM5E-A MD6 Series Maximum segment length 100 meters Between each port 160V min. 160V min. Switching Store & Forward FG to G • Designed specifically for Ethernet network • 4-20 mA & pulse signals (with the shortcircuit bar removed) Status Full duplex PAUSE Frames Device status LED • Conforms both to 100BASE-TX / 10BASE-T • Directly mountable to the cable Flow control Half duplex Back pressure ** RJ-45 connector contact is out of the scope of this protection. Protector • LAN cable’s shield wire can be floating or conduit of two-wire transmitters Using twisted-pair (STP) LAN cable is effective to reduce risk of fusing Surge Protector Life Monitor LED grounding by a shortcircuit bar. and other field devices in an Buffer 64 KB contact. MAC address table 1024 *** With the shortcircuit bar • DIN rail mounting outdoor enclosure • CE marking * Automatically sensing cable type (straight-through or cross-over).

50

51 Lightning Surge Protectors

M-System Lightning Surge Protectors absorb only the lightning Model MAKF One-Port Surge Protector For Power Supply Use surges with no interruption of the instrumentation signal Designed to protect electronics equipment from induced lightning surges entering through power supply cables Protects sensor, signal and power lines Connected in parallel between the power and ground lines regardless of load current Can be removed and tested without Varistor discharge element has a high speed response without follow current disconnecting wires No interruption of power supply even when the head element is removed: easy maintenance and replacing Superior protection and selection across Degraded head element is automatically separated from the power lines to a wide range of applications including: prevent overheating, with a relay contact output to alert the failure status 4-20 mA & pulse signal Head-base connection is keyed so that only a head element of correct line Thermocouple voltage can be mounted RTD Surge Current Flow (cross section) Potentiometer Strain gauge Thermal Breaker (cross section) Connection Examples Lightning Surge Frequency generating devices Telemetering devices Single-phase / 2-wire connection M5 screw (spring loaded) RS-485 / RS-422 Breaker Operation Protected Device G Metal Oxide Ethernet, DeviceNet, PROFIBUS, LONWORKS The alarm output switch is turned on. Varistor (MOV) AC/DC Power supply lines (1 amp up to 30 amps) 3

When the low temperature-melting Cross-wiring solder is melted by an abnormal high Grounding temperature at the discharge element, Model MDPA-24 Lightning Surge Protector with Life Monitor 1 the lever mechanism is released by the Single-phase / 3-wire, force of spring to separate the three-phase / 3-wire connection discharge element from the circuit. Designed specifically for 4-20 mA and pulse signal Protected Device ALM Indicator LED G BAT Indicator LED line including 4-wire/2-wire transmitters. The green failure indicator turns to 2 black at the same time. LIFE IDENTICATION Battery powered life monitoring system includes CHK Check Button ALT BAT Replacement Cross-wiring a ‘Test’ button with indicators alerting panel No Need Ground Near Grounding inspectors of the surge protector’s ‘health.’ Immediately CLOSE UP Required Model SHSP 8-Port Ethernet Switch with Surge Protector MDP-24-1 MA-100 / MA-200 • 4-20 mA & pulse signals • 120 Vac / 240 Vac power supply lines Surge protector function for each port • UL listed • 2 amps • CE marking • Fuse provided for supplementar Protects Ethernet devices from surges entering through LAN cables protection Surge protector life monitor function with LED and contact output alarm • CE marking Data transfer rate can be fixed

MDM2A-24 MAA-100 / MAA-200 LAN PORT SPECIFICATIONS SURGE PROTECTOR PERFORMANCE • 4-20 mA & pulse signals MAAC-100 / MAAC-200 FRONT VIEW • Life monitor • 120 Vac / 240 Vac power supply lines Standards IEEE 802.3, IEEE 802.3u, IEEE 802.3x Compliant standard EN61000-4-5 level X LINK LED • Alarm output • 5 amps Number of ports 8; All ports support AUTO-MDIX* Between ports 1kV (combination waveform) 100M LED • CE marking • Life monitor Data transfer rate 10 Mbps (10 BASE-T), Port to G 10kV (combination waveform)** 100 Mbps (100 BASE-TX); FG (shield) to G 15kV (combination waveform)*** • Surge counter function Supports Auto-Negotiation Voltage protection level LAN Ports (x 8) • CE marking 10 BASE-T (STP cable, category 5) RJ45 Connector Cable 100 BASE-TX (STP cable, category 5e) Port to FG or G 160V min. MDM5E-A MD6 Series Maximum segment length 100 meters Between each port 160V min. 160V min. Switching Store & Forward FG to G • Designed specifically for Ethernet network • 4-20 mA & pulse signals (with the shortcircuit bar removed) Status Full duplex PAUSE Frames Device status LED • Conforms both to 100BASE-TX / 10BASE-T • Directly mountable to the cable Flow control Half duplex Back pressure ** RJ-45 connector contact is out of the scope of this protection. Protector • LAN cable’s shield wire can be floating or conduit of two-wire transmitters Using twisted-pair (STP) LAN cable is effective to reduce risk of fusing Surge Protector Life Monitor LED grounding by a shortcircuit bar. and other field devices in an Buffer 64 KB contact. MAC address table 1024 *** With the shortcircuit bar • DIN rail mounting outdoor enclosure • CE marking * Automatically sensing cable type (straight-through or cross-over).

50

51 MD7 Series Ultra-Slim Lightning Surge Protectors

High-density mounting with 7-mm wide modules HIGH PERFORMANCE

Excellent protection by multi-stage SPD NEW The multi-stage protection combining discharge elements at the Ultra-slim Package, Unmatched Performance Max. discharge current 20 kA (8/20 µsec.) first stage and the series resistances and diodes ensures to limit the current flow. Metal DIN rail adaptor Independent shield Floating mode for the shield to avoid ground loops The maximum discharge current capacity is as high as 20 kA used for grounding terminal DIN rail mounting / grounding for an impulse wave of 8/20 microseconds. The MD7 Series are tested according to IEC 61643-21 standard to be suitable Loop disconnect fuse (option) for categories C1, C2 and D1. C1 category requires the surge Monitor LED (power supply line) FM intrinsically safe (pending) protector to withstand 300 times of average induced surges, C2 to withstand 10 times of strong induced surges generated in Loop disconnect fuse (standard signal line) The MD7 Series is a new family of surge protectors offered from M-System, a harsh environment without electromagnetic shielding. D1 specialist of signal conditioning who knows about a variety of electronic category is tested by two direct hits. devices interfacing field sensors and control rooms. SPECIFICATIONS - SURGE PROTECTORS FOR STANDARD SIGNAL LINE The MD7 surge protectors are multi-stage SPD, which, in addition to the discharge element at the first stage, provide an extra protection by a series Function 4-20 mA loop 2-wire 3-wire resistance with diodes to limit current flow. The maximum discharge current Model No. MD7(A)ST-24 MD7(A)ST-60MD72W-07MD72W-16 MD72W-32 MD72W-55 MD73W ± ± ± ± ± is up to 20 kA to further enhance its performance. Max. continuous operating voltage (Uc) 30V 70V 7V 16V 32V 55V 32V Voltage protection level (Up) 60V max. 115V max. 20V max. 30V max. 50V max. 80V max. ±60V max. All MD7 products have an independent set of shield terminals, therefore it is possible to choose ‘Floating’ or ‘Grounding’ shield Max. discharge current (Imax) 20 kA (8/20 µsec.), 1.0 kA (10/350 µsec.) terminal to suit users’ application needs. Floating mode is especially effective to prevent a ground loop. Test standard IEC 61643-21, cagetories C1, C2 and D1 The MD7 surge protectors are designed to earth ground through DIN rail, and by connecting the rail to the earth, they are CE marking Yes automatically grounded when they are mounted on it. No need of cross wiring. Life monitor Yes (MD7AST) ---- Model MD7ST has an optional ‘Loop Disconnect Fuse’ function to conveniently separate the protected device from the power bus to protect others when it has failed in shortcircuit mode. SPECIFICATIONS - SURGE PROTECTORS FOR SENSOR SIGNAL LINE MODEL APPLICATIONS Function Thermocouple RTD Potentiometer Strain Gauge MD7ST 4-20 mA loop Model No. MD7TC MD7RB MD7PM MD7LC-1 MD7LC-0 Wide adaptabillity: Easy wiring: Slanted terminals Series resistance ---- With Without 4-pole terminals MD7AST 4-20 mA loop, life monitor NEW Max. continuous operating voltage (Uc) 7.5V ±3V 7.5V Line side: ±0.2V Line side: ±0.2V 8 DIN rail 8 MD72W 2-wire transmitter loop 6 mounting / Exc. side: 15V Exc. side: 15V 6 5 MD72WD 2-wire transmitter loop (2 channels) Future Plan 5 4 grounding Voltage protection level (Up) 25V max. ±25V max. 25V max. Line side:± 40V max. Line side:± 15V max. 4 MD73W 3-wire transmitter loop Exc. side: 50V max.Exc. side: 30V max. Loop disconnect MD7TC Thermocouple transmitter µ µ 100 A (8/20µ sec.) fuse (MD7ST) Max. discharge current (Imax) 20 kA (8/20 sec.), 1.0 kA (10/350 sec.) MD7RB RTD & RTD transmitter Test standard IEC 61643-21, cagetories C1, C2 and D1 ---- 95 (3.74) MD7PM Potentiometer & transmitter CE marking Yes ---- Self-Synch & transmitter 1 1 MD7JS 2 Power LED 2 3 3 MD7LC Strain Gauge & transmitter SPECIFICATIONS - SURGE PROTECTORS FOR SENSOR, POWER SUPPLY LINE 7 (MD7DP) 7 MD7PL 2-Point Pulse Signal 98 (3.86) Function Self-Synch Pulse signal (PNP) Pulse signal (NPN) DC power supply 7 (.28) Only 7 mm MD74R RS-422 / RS-485 Model No. MD7JS MD7PL-P MD7PL-N MD7DP-12 MD7DP-24 wide unit: mm (inch) MD7PA PROFIBUS-PA Max. continuous operating voltage (Uc) ±130V -30V +30V 14V 27V MD7LWA LONWORKS Voltage protection level (Up) ±450V max. -50V max. +50V max. ±150V max. ±170V max. MD7FB FOUNDATION Max. discharge current (Imax) 20 kA (8/20 µsec.), 1.0 kA (10/350 µsec.) MD7DP DC power supply Test standard IEC 61643-21, cagetories C1, C2 and D1 MD7AP AC power supply Future Plan CE marking Yes

EASY COMMISSIONING SPECIFICATIONS - SURGE PROTECTORS FOR TRANSMISSION LINE Function RS-422 / RS-485 PROFIBUS-PA LONWORKS FOUNDATION Fieldbus The MD7 Series are designed for multi-point, ultra-high-density installation. DIN rail mounting/grounding and slanted terminal block help installation and wiring work in such tight space. Model No. MD74R MD7PA MD7LWA MD7FB Max. continuous operating voltage (Uc) ±5V ±32V ±1.5V ±32V When the DIN rail is grounded at single point, surge protectors mounted on it are automatically connected to the earth. There is no Voltage protection level (Up) ±25V max. ±60V max. ±30V max. ±60V max. need of cross-wiring individual module. Max. discharge current (Imax) 20 kA (8/20 µsec.), 1.0 kA (10/350 µsec.) Thanks to the terminal blocks slightly slanted forward, access from the front side to the terminals is easy even after the protectors are Test standard IEC 61643-21, cagetories C1, C2 and D1 mounted on the rail. CE marking Yes

52 53 MD7 Series Ultra-Slim Lightning Surge Protectors

High-density mounting with 7-mm wide modules HIGH PERFORMANCE

Excellent protection by multi-stage SPD NEW The multi-stage protection combining discharge elements at the Ultra-slim Package, Unmatched Performance Max. discharge current 20 kA (8/20 µsec.) first stage and the series resistances and diodes ensures to limit the current flow. Metal DIN rail adaptor Independent shield Floating mode for the shield to avoid ground loops The maximum discharge current capacity is as high as 20 kA used for grounding terminal DIN rail mounting / grounding for an impulse wave of 8/20 microseconds. The MD7 Series are tested according to IEC 61643-21 standard to be suitable Loop disconnect fuse (option) for categories C1, C2 and D1. C1 category requires the surge Monitor LED (power supply line) FM intrinsically safe (pending) protector to withstand 300 times of average induced surges, C2 to withstand 10 times of strong induced surges generated in Loop disconnect fuse (standard signal line) The MD7 Series is a new family of surge protectors offered from M-System, a harsh environment without electromagnetic shielding. D1 specialist of signal conditioning who knows about a variety of electronic category is tested by two direct hits. devices interfacing field sensors and control rooms. SPECIFICATIONS - SURGE PROTECTORS FOR STANDARD SIGNAL LINE The MD7 surge protectors are multi-stage SPD, which, in addition to the discharge element at the first stage, provide an extra protection by a series Function 4-20 mA loop 2-wire 3-wire resistance with diodes to limit current flow. The maximum discharge current Model No. MD7(A)ST-24 MD7(A)ST-60MD72W-07MD72W-16 MD72W-32 MD72W-55 MD73W ± ± ± ± ± is up to 20 kA to further enhance its performance. Max. continuous operating voltage (Uc) 30V 70V 7V 16V 32V 55V 32V Voltage protection level (Up) 60V max. 115V max. 20V max. 30V max. 50V max. 80V max. ±60V max. All MD7 products have an independent set of shield terminals, therefore it is possible to choose ‘Floating’ or ‘Grounding’ shield Max. discharge current (Imax) 20 kA (8/20 µsec.), 1.0 kA (10/350 µsec.) terminal to suit users’ application needs. Floating mode is especially effective to prevent a ground loop. Test standard IEC 61643-21, cagetories C1, C2 and D1 The MD7 surge protectors are designed to earth ground through DIN rail, and by connecting the rail to the earth, they are CE marking Yes automatically grounded when they are mounted on it. No need of cross wiring. Life monitor Yes (MD7AST) ---- Model MD7ST has an optional ‘Loop Disconnect Fuse’ function to conveniently separate the protected device from the power bus to protect others when it has failed in shortcircuit mode. SPECIFICATIONS - SURGE PROTECTORS FOR SENSOR SIGNAL LINE MODEL APPLICATIONS Function Thermocouple RTD Potentiometer Strain Gauge MD7ST 4-20 mA loop Model No. MD7TC MD7RB MD7PM MD7LC-1 MD7LC-0 Wide adaptabillity: Easy wiring: Slanted terminals Series resistance ---- With Without 4-pole terminals MD7AST 4-20 mA loop, life monitor NEW Max. continuous operating voltage (Uc) 7.5V ±3V 7.5V Line side: ±0.2V Line side: ±0.2V 8 DIN rail 8 MD72W 2-wire transmitter loop 6 mounting / Exc. side: 15V Exc. side: 15V 6 5 MD72WD 2-wire transmitter loop (2 channels) Future Plan 5 4 grounding Voltage protection level (Up) 25V max. ±25V max. 25V max. Line side:± 40V max. Line side:± 15V max. 4 MD73W 3-wire transmitter loop Exc. side: 50V max.Exc. side: 30V max. Loop disconnect MD7TC Thermocouple transmitter µ µ 100 A (8/20µ sec.) fuse (MD7ST) Max. discharge current (Imax) 20 kA (8/20 sec.), 1.0 kA (10/350 sec.) MD7RB RTD & RTD transmitter Test standard IEC 61643-21, cagetories C1, C2 and D1 ---- 95 (3.74) MD7PM Potentiometer & transmitter CE marking Yes ---- Self-Synch & transmitter 1 1 MD7JS 2 Power LED 2 3 3 MD7LC Strain Gauge & transmitter SPECIFICATIONS - SURGE PROTECTORS FOR SENSOR, POWER SUPPLY LINE 7 (MD7DP) 7 MD7PL 2-Point Pulse Signal 98 (3.86) Function Self-Synch Pulse signal (PNP) Pulse signal (NPN) DC power supply 7 (.28) Only 7 mm MD74R RS-422 / RS-485 Model No. MD7JS MD7PL-P MD7PL-N MD7DP-12 MD7DP-24 wide unit: mm (inch) MD7PA PROFIBUS-PA Max. continuous operating voltage (Uc) ±130V -30V +30V 14V 27V MD7LWA LONWORKS Voltage protection level (Up) ±450V max. -50V max. +50V max. ±150V max. ±170V max. MD7FB FOUNDATION Fieldbus Max. discharge current (Imax) 20 kA (8/20 µsec.), 1.0 kA (10/350 µsec.) MD7DP DC power supply Test standard IEC 61643-21, cagetories C1, C2 and D1 MD7AP AC power supply Future Plan CE marking Yes

EASY COMMISSIONING SPECIFICATIONS - SURGE PROTECTORS FOR TRANSMISSION LINE Function RS-422 / RS-485 PROFIBUS-PA LONWORKS FOUNDATION Fieldbus The MD7 Series are designed for multi-point, ultra-high-density installation. DIN rail mounting/grounding and slanted terminal block help installation and wiring work in such tight space. Model No. MD74R MD7PA MD7LWA MD7FB Max. continuous operating voltage (Uc) ±5V ±32V ±1.5V ±32V When the DIN rail is grounded at single point, surge protectors mounted on it are automatically connected to the earth. There is no Voltage protection level (Up) ±25V max. ±60V max. ±30V max. ±60V max. need of cross-wiring individual module. Max. discharge current (Imax) 20 kA (8/20 µsec.), 1.0 kA (10/350 µsec.) Thanks to the terminal blocks slightly slanted forward, access from the front side to the terminals is easy even after the protectors are Test standard IEC 61643-21, cagetories C1, C2 and D1 mounted on the rail. CE marking Yes

52 53 Electronic Actuators & Position Sensors

Electronic Actuators SERVOTOP II Series Mini-Top Series Failsafe Linear Linear & Rotary Electronic Actuators Electronic Actuators LINEAR MOTION TYPE Linear motion type MSP for thrust 700-2500 N Linear motion type PSN Model MSP4 MSP5 MSP6 PSN1 PSN3 CSP Rotary motion type MRP for torque 5-33 N·m for thrust 3000-5000 N Model (DeviceNet) MSP4D MSP5D MSP6D ------Model (CC-Link) MSP4C MSP5C MSP6C ------Max. stroke (mm) 15 mm 20 mm 40 mm 40 mm 60 mm 75 mm Max. stroke (inch) 0.59” 0.79” 1.57” 1.57” 2.36” 2.95” Max. thrust (N) 700 N 700 N 2500 N 3000 N 5000 N 12000 N FEATURES FEATURES Max. thrust (lbs) 157 lbs 157 lbs 562 lbs 674 lbs 1124 lbs 2697 lbs Resolution 1/1000 0.04 mm 0.06 mm Hysteresis 1 mm or less • Brushless angle sensor eliminates problems with mechanical • High resolution positioning for better valve control Input signal 4-20 mA or 1-5 V potentiometer feedback sensing • Built-in feedback positioner and electronic limiter Position output 1-5 Vdc 4-20 Vdc • 0.06 mm linear resolution for precise valve/damper positioning • Brushless stepping motor assures long-life operation Motor Stepping motor AC motor • Opening/closing speed, split range and failsafe position • 1/1000 resolution Position detection Potentiometer Brushless angle sensor Potentiometer programmable in-field Power input 24 Vdc, 100-120Vac, 200-240 Vac 100 Vac, 110 Vac • Internal temperature sensor to warm unit in cold climate or to APPLICATIONS 200 Vac, 220 Vac prevent motor burnout from overheating Degree of protection IP55 IP56 ---- Optional ---- • Forced-open/-closed contacts for remote or manual override • Pilot plants Failsafe function • Chemical injection/mixing APPLICATIONS • Tank valve control in brending machines • Chemical injection/mixing • Fuel valve control ROTARY MOTION TYPE • Fuel valve control • HVAC damper positioning Model MRP4 MRP5 MRP6 CRP-0 CRP-1 CRP-2 • Food machines • Petrochemical and pharmaceutical flow controls Model (DeviceNet) MRP4D MRP5D MRP6D ------• Wastewater flow control • Petrochemical, pharmaceutical, Model (CC-Link) MRP4C MRP5C MRP6C ------wastewater flow controls Max. angle 90°, 180° 90° 90°, 180° 90° • HVAC damper positioning Max. torque (N·m) 5 N·m 10 N·m 33 N·m 68.6 N·m 196 N·m 588 N·m • Food machines Brushless stepping motor Max. torque (ft·lbs) 3.69 ft·lbs 7.38 ft·lbs 24.3 ft·lbs 50.6 ft·lbs 144.7 ft·lbs 434.0 ft·lbs Enhances the durability and reliability of M-System’s Resolution 1/1000 0.45° electronic actuators. Input signal 4-20 mA or 1-5 V Unaffected by pressure fluctuations from the process Position output 1-5 Vdc 4-20 Vdc Line pressure fluctuations are absorbed by the screw shaft. Motor Stepping motor AC motor Sealing spring mechanism Position detection Potentiometer Built-in sealing spring retains the sealing pressure at the closed position. Power input 24 Vdc, 100-120 Vac, 200-240 Vac 100 Vac, 110 Vac, 200 Vac, 220 Vac Degree of protection IP55 Position Sensors M-System’s Model VOS2T and VOS2T-R are two-wire position transmitters incorporating a Model No. VOS2T VOS2T-R brushless angle sensor as their key sensing component. They detect rotating angles of Linear Motion Type Rotary Motion Type Diecast aluminum enclosure -22.5 to +22.5° -45 to +45° pneumatic and electric actuators and send 4 to 20 mAdc signal proportional to the angles. Input angle Direct/Reverse selector Mechanical angle -27 to +27° -55 to +55° They are also widely used in monitoring and automating various mechanical systems. Terminal block Stopper strength 1.37 N·m (1.011 ft·lbs) with static load Lever Output action Direct or Reverse FEATURES APPLICATIONS Output signal 4-20 mAdc Load resistance 0-600 Ω at 24 Vdc supply Indicator • Lightweight & compact design • Position transmitter for pneumatic control valve or dampers Supply voltage 15-28 Vdc • High resolution • Proportional control of an ON/OFF valve Degree of protection IP 66 Direct drive shaft • Direct and reverse actions are selectable • Position feedback for motor-driven systems or servo control systems Wiring conduit G 1/2” female thread in-field • Measuring roller position displacement in paper, cloth and other types of film feeders Operating temperature -5 to +60°C (23 to 140°F) • IP 66 diecast aluminum enclosure is • Upward/downward positioning for boarding bridges Maximum vibration 2 G Approx. weight 550 g (1.2 lbs) without lever or cable suitable for field applications • Rudder direction sensing Brushless angle sensor Cable gland Linearity 1.0% within the input angle • Liquid level sensing in reservoir tanks

54 55 Electronic Actuators & Position Sensors

Electronic Actuators SERVOTOP II Series Mini-Top Series Failsafe Linear Linear & Rotary Electronic Actuators Electronic Actuators LINEAR MOTION TYPE Linear motion type MSP for thrust 700-2500 N Linear motion type PSN Model MSP4 MSP5 MSP6 PSN1 PSN3 CSP Rotary motion type MRP for torque 5-33 N·m for thrust 3000-5000 N Model (DeviceNet) MSP4D MSP5D MSP6D ------Model (CC-Link) MSP4C MSP5C MSP6C ------Max. stroke (mm) 15 mm 20 mm 40 mm 40 mm 60 mm 75 mm Max. stroke (inch) 0.59” 0.79” 1.57” 1.57” 2.36” 2.95” Max. thrust (N) 700 N 700 N 2500 N 3000 N 5000 N 12000 N FEATURES FEATURES Max. thrust (lbs) 157 lbs 157 lbs 562 lbs 674 lbs 1124 lbs 2697 lbs Resolution 1/1000 0.04 mm 0.06 mm Hysteresis 1 mm or less • Brushless angle sensor eliminates problems with mechanical • High resolution positioning for better valve control Input signal 4-20 mA or 1-5 V potentiometer feedback sensing • Built-in feedback positioner and electronic limiter Position output 1-5 Vdc 4-20 Vdc • 0.06 mm linear resolution for precise valve/damper positioning • Brushless stepping motor assures long-life operation Motor Stepping motor AC motor • Opening/closing speed, split range and failsafe position • 1/1000 resolution Position detection Potentiometer Brushless angle sensor Potentiometer programmable in-field Power input 24 Vdc, 100-120Vac, 200-240 Vac 100 Vac, 110 Vac • Internal temperature sensor to warm unit in cold climate or to APPLICATIONS 200 Vac, 220 Vac prevent motor burnout from overheating Degree of protection IP55 IP56 ---- Optional ---- • Forced-open/-closed contacts for remote or manual override • Pilot plants Failsafe function • Chemical injection/mixing APPLICATIONS • Tank valve control in brending machines • Chemical injection/mixing • Fuel valve control ROTARY MOTION TYPE • Fuel valve control • HVAC damper positioning Model MRP4 MRP5 MRP6 CRP-0 CRP-1 CRP-2 • Food machines • Petrochemical and pharmaceutical flow controls Model (DeviceNet) MRP4D MRP5D MRP6D ------• Wastewater flow control • Petrochemical, pharmaceutical, Model (CC-Link) MRP4C MRP5C MRP6C ------wastewater flow controls Max. angle 90°, 180° 90° 90°, 180° 90° • HVAC damper positioning Max. torque (N·m) 5 N·m 10 N·m 33 N·m 68.6 N·m 196 N·m 588 N·m • Food machines Brushless stepping motor Max. torque (ft·lbs) 3.69 ft·lbs 7.38 ft·lbs 24.3 ft·lbs 50.6 ft·lbs 144.7 ft·lbs 434.0 ft·lbs Enhances the durability and reliability of M-System’s Resolution 1/1000 0.45° electronic actuators. Input signal 4-20 mA or 1-5 V Unaffected by pressure fluctuations from the process Position output 1-5 Vdc 4-20 Vdc Line pressure fluctuations are absorbed by the screw shaft. Motor Stepping motor AC motor Sealing spring mechanism Position detection Potentiometer Built-in sealing spring retains the sealing pressure at the closed position. Power input 24 Vdc, 100-120 Vac, 200-240 Vac 100 Vac, 110 Vac, 200 Vac, 220 Vac Degree of protection IP55 Position Sensors M-System’s Model VOS2T and VOS2T-R are two-wire position transmitters incorporating a Model No. VOS2T VOS2T-R brushless angle sensor as their key sensing component. They detect rotating angles of Linear Motion Type Rotary Motion Type Diecast aluminum enclosure -22.5 to +22.5° -45 to +45° pneumatic and electric actuators and send 4 to 20 mAdc signal proportional to the angles. Input angle Direct/Reverse selector Mechanical angle -27 to +27° -55 to +55° They are also widely used in monitoring and automating various mechanical systems. Terminal block Stopper strength 1.37 N·m (1.011 ft·lbs) with static load Lever Output action Direct or Reverse FEATURES APPLICATIONS Output signal 4-20 mAdc Load resistance 0-600 Ω at 24 Vdc supply Indicator • Lightweight & compact design • Position transmitter for pneumatic control valve or dampers Supply voltage 15-28 Vdc • High resolution • Proportional control of an ON/OFF valve Degree of protection IP 66 Direct drive shaft • Direct and reverse actions are selectable • Position feedback for motor-driven systems or servo control systems Wiring conduit G 1/2” female thread in-field • Measuring roller position displacement in paper, cloth and other types of film feeders Operating temperature -5 to +60°C (23 to 140°F) • IP 66 diecast aluminum enclosure is • Upward/downward positioning for boarding bridges Maximum vibration 2 G Approx. weight 550 g (1.2 lbs) without lever or cable suitable for field applications • Rudder direction sensing Brushless angle sensor Cable gland Linearity 1.0% within the input angle • Liquid level sensing in reservoir tanks

54 55 Four-wire Signal Conditioners

Two-wire Signal Conditioners

Function Modules

Limit Alarms

Power Transducers

Remote I/O

PC Recorder 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81(6)6659-8201 Fax: +81(6)6659-8510 Paperless Recorders URL: www.m-system.co.jp 20092009 E-mail: [email protected] Panel Meters

Lightning Surge Protectors

Electronic Actuators

Position Sensors

EC-Z906 Rev.6 January 2009

500365