IAQ Economizer LOGIC BOX
Total Page:16
File Type:pdf, Size:1020Kb
IAQ Economizer LOGIC BOX Split-system Economizing/Indoor Air Quality/CO Alarm Activated Works on forced air systems, with or without air conditioning installed Enables cost saving cooling strategy: Expensive mechanical cooling can be set at a higher temperature Fresh Air Cooling can be set at a lower temperature Supports a variety Indoor Air Quality configurations: Continuous introduction Timed introduction CO2 or VOC sensor activated introduction Provides alarm activated fresh air introduction supporting CO or other alarm installations Occupant interface provides easy override, along with readiness, damper and fault status, (continuous fault detection) Operational tests can be conducted from within the conditioned space Quick connect wiring harnesses provide fast, correct termination FRESH AIR MANUFACTURING CO. FAMCO IAQ Economizer Famcoiaq.com 649 N. Ralstin St., Meridian, ID 83642 * (208)884-8931 * (800)-234-1903 * FAX: (208)884-8943 IAQ Economizer ECONOMIZER SYSTEM Damper Actuator Exhaust Damper Transformer Thermostat Logic Literature Box Cables Damper Box Actuator – Honeywell MS8105A1030, 24 VAC, 44 lb-in torque Outdoor thermostat- Dayton RLZ94A Nema 4X, Range 30º-110º F Transformer – RIB Functional Devices, Inc. TR50VA005 , 50VA All required System Cables are provided: • Power 40’ • Furnace 40’, plenum rated, HVAC industry standard color coding for furnace board termination • Damper Box 50’, plenum rated • Outdoor thermostat, 70’ , shielded, non polarity sensitive FRESH AIR MANUFACTURING CO. FAMCO IAQ Economizer Famcoiaq.com 649 N. Ralstin St., Meridian, ID 83642 * (208)884-8931 * (800)-234-1903 * FAX: (208)884-8943 IAQ Economizer INTAKE OPTIONS OR LOUVER INTAKE ROOF INTAKE Outside air intake penetration can be made through a gable or wall using the louver intake, (North or West side preferred) A roof intake option is available for homes that cannot accommodate wall penetrations If a roof intake is used, and the home does not have a filter located at the air handler, a filter will need to be installed The outside air thermostat, should be installed on the outside of the home or structure in the coolest location available. This is typically on the north side of the structure FRESH AIR MANUFACTURING CO. FAMCO IAQ Economizer Famcoiaq.com 649 N. Ralstin St., Meridian, ID 83642 * (208)884-8931 * (800)-234-1903 * FAX: (208)884-8943 IAQ Economizer LOGIC BOX Gang box or Surface mount options. Quick connect wiring. Easy Manual override. LED Status indication. FRESH AIR MANUFACTURING CO. FAMCO IAQ Economizer Famcoiaq.com 649 N. Ralstin St., Meridian, ID 83642 * (208)884-8931 * (800)-234-1903 * FAX: (208)884-8943 IAQ Economizer DAMPER BOX Collars are 4” wide and they ship detached for easy attic access Ships pre-insulated with R-8 insulation Durable 22 gauge construction, with 18 gauge reinforcements Weight 47 lbs. with insulation FRESH AIR MANUFACTURING CO. FAMCO IAQ Economizer Famcoiaq.com 649 N. Ralstin St., Meridian, ID 83642 * (208)884-8931 * (800)-234-1903 * FAX: (208)884-8943 IAQ Economizer INTAKE VENTS OPTIONS Wall Intake Option Powder coated white Made of 24 gauge With 1/4” mesh screen Roof Intake Option. Powder coated black 24 gauge steel With 1/8” mesh screen FRESH AIR MANUFACTURING CO. FAMCO IAQ Economizer Famcoiaq.com 649 N. Ralstin St., Meridian, ID 83642 * (208)884-8931 * (800)-234-1903 * FAX: (208)884-8943.