Aquareef 300 / 400 Series II
Total Page:16
File Type:pdf, Size:1020Kb
1+1 AquaReef Inspiring Excellence in Fish Care! 300 / 400 Series II Instruction version: 5/4/2016 www.aquaone.com.au Important Safeguards To guard against injury, basic safety precautions 8. Do not install or store the appliance where it will be should be observed, including the following: exposed to weather or temperatures below freezing. 1. Read and follow all safety instructions and important 9. Make sure any component mounted on a tank is notices in these instructions as well as on the product securely installed before operating it. itself. 10. Ensure input voltage is the same voltage as your 2. This appliance is not intended for use by children local power supply. or infirm persons without supervision. Young children should be supervised to ensure that they do not play 11. If an extension cable is used it should have the with the appliance. proper rating. Care should be taken to arrange the cord so that it will not be tripped or pulled. 3. To avoid possible electric shocks, special care should be taken since water is employed in the use 12. A G.F.C.I (Ground fault circuit interrupter) & surge of aquarium equipment. For each of the following protector is recommended for all electrical appliances. situations do not attempt repairs yourself. Return the appliance to an authorised service facility for service or 13. Ensure your hands are dry when turning the power discard the appliance. switch on/off and when inserting/removing the power cable from the socket. a. If the appliance or any electrical component of the appliance (non-immersible equipment only) falls into 14. If you are in any doubt about the electrical installation the water or gets wet, do not reach for it. Unplug it and or safety of this product you must consult a qualified then retrieve it. electrician. b. If the appliance shows any sign of abnormal water leakage, immediately unplug it from the power source. c. Carefully examine the appliance after installation. It should not be plugged in if there is water on parts which are not intended to be wet. d. Do not operate the appliance if it has a damaged cord or plug, or if it is malfunctioning, or dropped or damaged in any manner. 4. A “drip loop” (see graphic) should be arranged for each cable connecting an aquarium to a power supply. The drip loop is the part of the cable below the level of the power supply. It prevents water travelling down the For Guarantee Conditions, please refer to the cable and coming into contact with the power supply. If Guarantee form that is enclosed with this product. the plug or the socket does get wet, do not unplug the appliance. Disconnect the fuse or circuit breaker that All products are supplied with fitted plugs. This plug supplies the power to the appliance, then unplug and should not be tampered with in any way or removed. examine for presence of water in the socket. Removal or tampering with the plug invalidates our guarantee offered with this product. 5. Always unplug the appliance from the electrical outlet when not in use, before putting on or taking off parts, For UK a 3 pin adaptor is supplied with the product and before any type of maintenance or cleaning. this must be used. 6. Never yank the cable to pull it from the socket. Pull the plug carefully to disconnect. 7. Do not use the appliance for reasons other than the intended use. The use of attachments that are not recommended or sold by the manufacturer may cause the product to be unsafe. This is not recommended. 2 Before First Use / Preparation Read and follow all the instructions, even if you feel you are familiar with the product and find a place to Replacement Parts & Filter Media keep the instructions handy for future reference. Use Aqua One Genuine Spare Parts Only. See your Your attention is drawn particularly to the sections local Aqua One Dealer and look for the number concerning “IMPORTANT SAFEGUARDS” and the listed below for the spare part you require. “GUARANTEE CONDITIONS”. Please ensure you retain your original purchase receipt in the event that guarantee service is required. Carefully unpack the aquarium making sure you Filter Sock 50103 keep all the packing material until all the parts of the product have been found and the product has been assembled. This product is shipped to you in a factory sealed carton. Should the product malfunction in any way or if the unit is damaged and requires replacement, contact the retailer where the product was purchased for inspection. Know Your Filter Aquareef 300 / 400 Placement of Aqua One Elite Set up/Parts Skim 600 (sold separately) 1. Filter Sock 2. Heaters Placement of Aqua One 3. Protein Skimmer Proskim G220 Protein Skimmer (sold separately) (Sold Separately) 4. Return Pump 5. Top-up Reservoir 3 Set Up Instructions All plumbing components are already glued drain pipe so they can be connected using the into place except where threaded joints are barrel union. required for assembly into the aquarium or to allow access for maintenance. Two people will 5. Attach the outlet (4) to the return pipe by be required to connect the plumbing through pushing into the elbow. The connection should the base of the aquarium, one to access from pass through a hole in the overflow grill. above the weir and one to hold pipes in place below the aquarium. 6. Adjust the siphon break tube (7) so that it points downward. 1. Insert the threaded end of the drain pipe (1) into the larger hole in the base of the weir. 7. Ensure the hole in the top of the drain pipe Ensure the rubber grommet is placed between remains free, this will minimise noise caused the glass and the connection. as water exits the aquarium. 2. Attach the lower drain pipe (2) to the male 8. Follow the instructions provided with the return thread beneath the aquarium. Ensure a rubber pump to install into the sump. Place the pump in grommet is in place beneath the glass. Do the position noted on page 3 and use the elbow NOT overtighten, hand tightened is sufficient. intake as described in the instructions. A short length of flexible hose is provided to connect the 3. Repeat step 1 and 2 with the return pipes pump to the return pipe (3). A hose clamp is also (5 & 6). Ensure rubber grommets are used provided to secure the hose onto the pipe. on both sides of the glass and the threaded elbow at the top of the return pipe is facing 9. Unpack the filter sock and place in the towards the front of the aquarium. location shown on page 3. 4. Attach the lower elbow (3) to the drain pipe 10. Fill the aquarium with water such that the (2). The elbow should be facing the lower water overflows into the sump and fills the last section (where the return pump sits) to 7 the maximum operating water level mark. When running, the water level should always 4 remain above the minimum operating water level mark. 11. The heaters should be placed in the first 1 5 (left) section of the sump, immedately after the filter sock where the water level is highest and stays constant. Refer to location (2) noted on page 3. 12. Place protein skimmer (sold separately) inside the sump. Refer to location (3) illustrated on page 3. 2 6 NOTE: Plumbers tape is supplied on threaded fittings; it is highly recommended that this be replaced if the plumbing is disconnected at 3 any time. 4 Maintenance For maintenance instructions regarding 1. Wash your hands. the protein skimmer (sold separately) and 2. Mix up your salt water according to the return pump, refer to the instruction booklets directions on the packaging of the salt mix. Or, provided with each item. have your premixed/natural salt water ready. DAILY: 3. Check the pH, temperature and specific gravity of both the aquarium water and the Feed your fish as per instructions on your fish new water. Make any adjustments that need food container. to be made to the new water. You may want to purchase an extra heater to warm the new Check temperature water. Ensure all equipment is running correctly. 4. Once the water is ready to use, remove the light unit and glass lids and place them Ensure water level is safely above the somewhere safe away from the water where minimum operating water level mark. When they will not be broken or damaged. topping up evaporated water, always use dechlorinated tap water or suitably filtered 5. Turn the heaters and pump off. water. When water evaporates from the aquarium, salt remains in the water so topping 6. Place a towel on the floor in front of the up with salt water will increase the salinity of aquarium to guard from water spillage. the aquarium. Check salinity after topping up. 7. Use an algae scraper and gently remove WEEKLY: any algae that is growing on the glass. Test water parameters including pH, ammonia, 8. Using a gravel cleaner, remove 25% of nitrite, nitrate, phosphate, carbonate hardness the aquarium water. Take note of how much and specific gravity (salinity). If you are keeping water is removed and be sure to have enough coral or other sensitive marine animals you prepared water to replace all that is removed. may wish to perform further testing. Seek advice from your marine aquarium specialist. 9. Remove the filter sock from the sump and rinse it in water that has been removed from Use quality test kits, Aqua One have a range the aquarium.