Liquistation CSF39 Automatic Sampler for Liquid Media
Total Page:16
File Type:pdf, Size:1020Kb
BA01407C/07/EN/03.17 Products Solutions Services 71370574 Valid as of version 01.06.04 Operating Instructions Liquistation CSF39 Automatic sampler for liquid media Liquistation CSF39 Table of contents Table of contents 1 About this document ................ 5 8.2 Access to the operating menu via the local display ............................. 46 1.1 Warnings ............................ 5 8.3 Configuration options .................. 47 1.2 Symbols .............................. 5 1.3 Symbols on the device ................... 5 1.4 Documentation ........................ 6 9 Commissioning .................... 50 9.1 Function check ....................... 50 2 Basic safety instructions ............ 7 9.2 Switching on ......................... 50 9.3 Basic setup .......................... 51 2.1 Requirements for personnel ............... 7 9.4 Sampling programs .................... 52 2.2 Designated use ........................ 7 2.3 Occupational safety ..................... 7 2.4 Operational safety ...................... 8 10 Operation ......................... 55 2.5 Product safety ......................... 9 10.1 Display ............................. 55 10.2 General settings ....................... 56 3 Device description ................. 10 10.3 Programming ........................ 73 10.4 Inputs .............................. 95 3.1 Device design ......................... 10 10.5 Outputs ............................ 101 3.2 Equipment architecture ................. 11 10.6 Additional functions .................. 109 3.3 Terminal diagram ..................... 12 11 Diagnostics and troubleshooting .. 129 4 Incoming acceptance and product 11.1 General troubleshooting ................ 129 identification ..................... 13 11.2 Diagnostic information on local display ..... 130 4.1 Incoming acceptance ................... 13 11.3 Diagnostic information via Web browser ... 130 4.2 Product identification ................... 13 11.4 Diagnostic information via fieldbus ........ 130 4.3 Scope of delivery ...................... 14 11.5 Adapting the diagnostic information ...... 131 4.4 Certificates and approvals ............... 14 11.6 Overview of diagnostic information ....... 132 11.7 Pending diagnostic messages ............ 141 5 Installation ....................... 15 11.8 Diagnosis list ........................ 142 11.9 Logbooks ........................... 142 5.1 Installation conditions .................. 15 11.10 Device information ................... 148 5.2 Installation .......................... 18 11.11 Simulation .......................... 149 5.3 Post-installation check .................. 20 11.12 Device test .......................... 151 11.13 Resetting the measuring device .......... 153 6 Electrical connection .............. 21 11.14 Operating time information ............. 153 6.1 Connecting the sampler ................. 21 11.15 Status of inputs/outputs ................ 154 6.2 Connecting modules and sensors .......... 25 11.16 Firmware history ..................... 155 6.3 Terminal assignment for input/output signals .............................. 32 12 Maintenance .................... 158 6.4 Connection conditions .................. 32 12.1 Recommended maintenance ............ 158 6.5 Connecting additional inputs, outputs or 12.2 Calibration ......................... 159 relays .............................. 34 12.3 Replacing the pump tube ............... 162 6.6 Connecting digital communication ......... 35 12.4 Cleaning ........................... 164 6.7 Hardware settings ..................... 38 12.5 Replacing the rechargeable batteries ...... 168 6.8 Ensuring the degree of protection .......... 39 12.6 Technical support .................... 169 6.9 Post-connection check .................. 40 13 Repair ........................... 170 7 System integration ................ 41 13.1 Spare parts ......................... 170 7.1 Web server .......................... 41 13.2 Return ............................. 172 7.2 Service interface ...................... 42 13.3 Disposal ........................... 173 7.3 Fieldbuses ........................... 43 14 Accessories ...................... 174 8 Operation options ................. 45 14.1 Measuring cable ..................... 175 8.1 Overview ............................ 45 14.2 Sensors ............................ 175 Endress+Hauser 3 Table of contents Liquistation CSF39 15 Technical data ................... 180 Index ................................. 188 4 Endress+Hauser Liquistation CSF39 About this document 1 About this document 1.1 Warnings Structure of information Meaning LDANGER This symbol alerts you to a dangerous situation. Causes (/consequences) Failure to avoid the dangerous situation will result in a fatal or serious If necessary, Consequences of injury. non-compliance (if applicable) ‣ Corrective action LWARNING This symbol alerts you to a dangerous situation. Causes (/consequences) Failure to avoid the dangerous situation can result in a fatal or serious If necessary, Consequences of injury. non-compliance (if applicable) ‣ Corrective action LCAUTION This symbol alerts you to a dangerous situation. Causes (/consequences) Failure to avoid this situation can result in minor or more serious injuries. If necessary, Consequences of non-compliance (if applicable) ‣ Corrective action NOTICE This symbol alerts you to situations which may result in damage to Cause/situation property. If necessary, Consequences of non-compliance (if applicable) ‣ Action/note 1.2 Symbols Symbol Meaning Additional information, tips Permitted or recommended Not permitted or not recommended Reference to device documentation Reference to page Reference to graphic Result of a step 1.3 Symbols on the device Symbol Meaning Reference to device documentation Endress+Hauser 5 About this document Liquistation CSF39 1.4 Documentation The following manuals which are available on the complement these Brief Operating Instructions Operating Instructions: • Brief Operating Instructions for • Operating Instructions for Memosens, BA01245C – Software description for Memosens inputs – Calibration of Memosens sensors – Sensor-specific diagnostics and troubleshooting • Operating Instructions for HART communication, BA00486C – Onsite settings and installation instructions for HART – Description of HART driver • Guidelines for communication via fieldbus and web server – HART, SD01187C – PROFIBUS, SD01188C – Modbus, SD01189C – Web server, SD01190C – Web server (optional), SD01190C – EtherNet/IP, SD01293C • Special Documentation: Sampler application manual SD01068C • Documentation on other devices in the Liquiline platform: – Liquiline CM44xR (DIN rail device) – Liquiline System CA80 (analyzer) – Liquiline System CAT8x0 (sample preparation) – Liquistation CSFxx (sampler) – Liquiport CSP44 (sampler) 6 Endress+Hauser Liquistation CSF39 Basic safety instructions 2 Basic safety instructions 2.1 Requirements for personnel • Installation, commissioning, operation and maintenance of the measuring system may be carried out only by specially trained technical personnel. • The technical personnel must be authorized by the plant operator to carry out the specified activities. • The electrical connection may be performed only by an electrical technician. • The technical personnel must have read and understood these Operating Instructions and must follow the instructions contained therein. • Faults at the measuring point may only be rectified by authorized and specially trained personnel. Repairs not described in the Operating Instructions provided must be carried out only directly at the manufacturer's site or by the service organization. 2.2 Designated use Liquistation CSF39 is a stationary sampler for liquid media. The samples are taken discontinuously using a vacuum pump or peristaltic pump and are then distributed into sampling containers and refrigerated. The sampler is designed for use in the following applications: • Communal and industrial wastewater treatment plants • Laboratories and water management offices • Monitoring of liquid media in industrial processes Use of the device for any purpose other than that described, poses a threat to the safety of people and of the entire measuring system and is therefore not permitted. The manufacturer is not liable for damage caused by improper or non-designated use. 2.3 Occupational safety As the user, you are responsible for complying with the following safety conditions: • Installation guidelines • Local standards and regulations • Regulations for explosion protection Electromagnetic compatibility • The product has been tested for electromagnetic compatibility in accordance with the applicable European standards for industrial applications. • The electromagnetic compatibility indicated applies only to a product that has been connected in accordance with these Operating Instructions. Endress+Hauser 7 Basic safety instructions Liquistation CSF39 2.4 Operational safety 1. Before commissioning the complete measuring point, verify that all connections are correct. Ensure that electrical cables and hose connections are undamaged. 2. Do not operate damaged products, and protect them against unintentional operation. Label the damaged product as defective. 3. If faults cannot be rectified, products must be taken out of service and protected against unintentional operation. LCAUTION Cleaning not switched off during calibration or maintenance activities Risk of injury due to medium or cleaning agent ‣ If a cleaning system is connected, switch if off before removing