Vol.97 (2003) (SUPPLEMENT B),Sl I-Sl4

The response of two different dosages of dipropionate suspension for nebulization versus a standard dose of beclometasone dipropionate via a metered-dose on bronchoprovocation testing in adults with

J. BOUSQUET~ , H. MEZIANE~, F?CHANEZ’, M. MUESER~ AND A. UMILE~

‘Hopita Arnaud devilleneuve, Montpellier, France; 2Chiesi SA, Paris, France; Xhiesi Group, Parma, Italy

Abstract The objective of this double-blind, randomized, placebo-controlled, parallel-group study was to compare the pharmacodynamic effects and safety of beclometasone dipropionate (BDP) given by nebulization or metered-dose inhalation in adult patients with asthma. Following a I -weel< run-in period, 40 patients, aged 18-60 years, with intermittent bronchial asthma were randomized to one of four treatment groups for 3 weelrl suspension for nebulization group compared with pre-treatment for other parameters, including FEV, and peak expiratory flow rates. All treatments were comparable. All treatments were equally well tolerated. No significant effects on cortisol levels were reported in any of the treatment groups.

0 2003 Elsevler Science Ltd

INTRODUCTION formulation of BDP suspension for nebulization by The aim of treatment with nebulizers is to deliver a comparing the efficacy and safety of two different dosages therapeutic dose of the drug in the form of respirable administered via a nebulizer with those of a standard particles within a short period of time, usually dose of BDP administered via an MDI plus spacer (BDP 5-l 0 minutes (I). Efficient nebulizer therapy requires a MDI) in adults with intermittent bronchial asthma, using device that repeatedly and quickly delivers sufficient drug the methacholine bronchoprovocation test as the to the site of the action and with minimal wastage. primary pharmacodynamic variable and the measurement Nebulizers used in aerosol drug delivery produce a of FEV, and peak flow as secondary endpoints. polydisperse aerosol where most of the drug released is contained in particles l-5 urn in diameter. Most MATERIALS AND METHODS nebulizers use compressed air for administration, but some use ultrasonic energy (2,3). Male and female patients, aged 18-60 years, with a clinical It has been reported that beclometasone dipropionate diagnosis of bronchial asthma of intermittent severity (as (BDP) suspension for nebulization 800 ug, delivered via a defined according to the GINA classification), predicted nebulizer, yields a respirable dose of 195 ug, which is forced expiratory volume in I second (FEV,) of 2 80% at approximately double the respirable dose obtained with screening after at least an 8-h washout of inhaled p- BDP pressurized MDI 250 ug (95 ug), thus suggesting that agonist, positive response to the bronchial provocation in order to attain equivalent in-vivo performance the test to methacholine (defined as a decrease of 20% in nebulizer product would be expected to be used in a dose FEV, with inhalation of I8 mg ml-l), and body mass ratio of 2: I with respect to the pressurized inhaler (4). index of 18-35 kg m-z, and who were ambulatory, were The purpose of this clinical pharmacology study was to eligible to participate in the study. Patients with a history establish a dose-response relationship for a new of clinically significant major disorders or who received Sl2 RESPIRATORYMEDICINE an investigational drug in the previous 3 months were from baseline (PC,,). Secondary pharmacodynamic excluded from the randomization. variables were FEV,, morning PEFR, and PEFR variability. Safety parameters were random morning cortisol levels, Study design physical examination, vital signs, temperature, various This was a 4-week, double-blind, randomized, placebo- laboratory safety tests, and adverse events. controlled study undertaken in four parallel groups at two centres. Following a l-week run-in period, patients Statistical analysis who met study entry criteria were assigned to one of the No formal power calculations were undertaken for this four treatment groups for an active treatment period of study since it is an efficacy study and hence there should 3 weeks: BDP suspension for nebulization I600 pg day-’ be adequate data for power.The sample size was based on b.i.d. (Clenil-A@, Chiesi Farmaceutici SpA, Italy), plus previous data from similar studies involving comparisons placebo suspension for nebulization twice-daily, plus two of inhaled steroids in mild asthmatics using methacholine puffs twice-daily of placebo spray; BDP suspension for bronchial provocation as a method to determine efficacy. nebulization 3200 I-18 day-’ b.i.d., plus two puffs twice- Statistical analysis of the bronchial provocation test was daily of placebo spray; BDP spray 800 .ug day-1 b.i.d. carried out by calculating the mean ratio of PC,, values at (Becotide@, Allen & Hanburys, U.K.) (two puffs twice- study end/PC,, values pretreatment, of predicted FEV, by daily), plus placebo suspension for nebulization twice- calculating the difference in mean values between baseline daily; or placebo suspension for nebulization twice-daily, and study end, of morning PEFR and PEFR variability by plus two puffs twice-daily of placebo spray. The calculating the difference between mean values at the start suspension for nebulization was administered using the of run-in - pretreatment and poststudy, and of random air compression Pari LC Plus@ nebulizer (Pari Turbo cortisol concentrations by calculating the difference Boy@) (Pari, Germany), and the spray was given via an between mean values at baseline and study end. Within- MDI plus spacer (Volumatic@, Allen & Hanburys, U.K.). and between-treatment comparisons were undertaken Theophyllines, inhaled (other than the test BDP) or oral using one- or two-sample t tests. , and long-acting inhaled P-agonists were excluded.The use of short-acting inhaled &-agonists at RESULTS the same dosage used previously, inhaled or oral sodium cromoglycate or nedocromil sodium at a constant Patient population dosage during the study period, oral P-agonists, anti- In total, 40 patients were randomized: IO to the BDP cholinergics, , and antagonists I600 pg day-’ nebulization group, IO to the BDP was permitted. Patients were assessed at clinic visits 3200 pgday’ nebulization group, IO to the BDP MDI before and postrandomization. group, and IO to the placebo group. All enrolled patients Bronchoprevention testing was performed at baseline completed the trial. Assessment of safety was based on and after 3 weeks of study . Increasing all randomized patients. Patient demography at baseline concentrations of methacholine from 0.0625 mg ml-1 to was comparable for the four groups in the randomized I28 mg ml-’ were administered via an air compressor- population (Table I). driven nebulizer (Pari LC Plus@), doubling the concentration at each step. FEV, was measured following Evaluation of efficacy: each increase in methacholine dose. FEV,, measured using the Vitalograph-compact spirometer, physical bronchial provocation test examination, vital signs, temperature, laboratory safety Increases in PC,, were seen with all active treatment tests, and random morning serum cortisol levels were groups at the end of the 3-week treatment period assessed at baseline and at the end of the treatment. compared with pretreatment, with the improvement Morning peak expiratory flow rate (PEFR) was measured reported in the BDP 32OO~gday’ nebulization group daily by patients using a Mini-Wright@ peak flow meter being statistically significant. However, there were no (Clement Clarke International, Essex, U.K.) and the best statistically significant differences in PC,, between any of of three measurements recorded on a diary card. The the active treatment groups at the end of the study.The institutional review board for each treatment centre mean study end/pretreatment bronchoprovocation test approved the protocol, and written informed consent ratio for each treatment group is shown in Figure I. was obtained from the patients. Assessments Evaluation of efficacy: The primary pharmacodynamic endpoint was the change Other measures of pulmonary function in FEV, in response to methacholine bronchial provoca- Similar changes in mean predicted FEV, values were tion testing, by determining the change in concentration observed in all active treatment groups at treatment end of methacholine that resulted in 20% reduction in FEV, when compared with baseline. BDP SUSPENSION FOR NEBULIZATION VS BDPVIA MDI ON BRONCHOPROVOCATION TESTING Sl3

Changes in morning PEFR were of limited clinical Mean Day 21 /Day-l Bronchial Provocation Test Ratio significance because patients were mild asthmatics with "1 (Standard Deviation) high baseline PEFR values and statistically significant d T differences were found between the groups prior to treatment (Table 2). Both of the BDP nebulization groups produced similar changes in mean PEFR variability at study end vs pretreatment, and an increase was shown in the BDP 1 MDI group that was statistically significant. This unexpected latter finding may be explained by the fact 0 Placebo BDP metered dose Nebulized BDP Nebulized BDP that the group size was not powered. -1 J inhaler 800 kg 1600 pg 3200 bg Treatment

Evaluation of safety FIGURE I. Mean values for study end/pretreatment broncho- provocation test ratio (standard deviation) in the randomized Safety data showed that all active treatments were well population of adults with intermittent bronchial asthma after tolerated. During the treatment period, 23 patients (five 3 weel

Mean Random Cortisol fl Standard Deviatmn 1000 group), demonstrated a protection of bronchial hyper-

900 ZR Baseline reactivity with the different types of active treatment, a 800 T Post-treatment significant dose effect at the highest dosage level of 700-1 T/ TT TT T- nebulized BDP and equivalent effects with BDP L 600 I600 pg day-l nebulization and BDP MDI 800 pg day’. z 500 The data showed that only nebulized BDP 3200 pg day’ g 400 produced a significant change in PC,, between 300 200 pretreatment and study end, but a between-treatment too analysis indicated that there was no treatment-related 0 difference when compared with placebo. Placebo ‘BDP metered dose’ Nebulized BDP Nebulized BDP inhaler 800 pg 1600 kg 3200 pg The study was intended as a comparison of efficacy on TI.SltTIU3lt bronchial reactivity to confirm a dose response and that the 2:1 ratio of nebulized BDP to BDP MDI was FIGURE 2. Mean values for random morning cortisol levels k appropriate. The within-treatment difference observed standard deviation in the randomized population of adults with intermittent bronchial asthma at baseline and after 3 weeks of with BDP nebulization 3200 pgday-1 compared with treatment with beclometasone dipropionate given by baseline is supportive of a trend towards a dose nebulization or metered-dose inhalation, or placebo. response.The absence of between-treatment differences indicates that the proposed 2: I ratio is appropriate, and that BDP nebulization I600 pg day-’ is indistinguishable Several studies have compared the efficacy of from BDP MDI 800pgday1. The increased systemic given via nebulizer and MDI. In a study of 2 I exposure would justify use of BDP 3200 pgday-1 adult patients with asthma, budesonide suspension nebulization in subjects with more severe asthma. delivered from a nebulizer activated during inspiration All three active treatments were equally well exhibited a dose-dependent effect, apparently equipotent tolerated, as demonstrated by examining a number of to the MDI administration as evaluated from daily peak safety parameters. Furthermore, morning serum cortisol expiratory flow (PEF) measurements and symptom levels remained within normal ranges and, although not scoring (5). Continuous nebulization of budesonide in I8 statistically significant (probably on account of the small schoolchildren with bronchial asthma similarly showed a number of patients in each group), the results indicated dose-dependent improvement of lung function and a dose effect with nebulized BDP and an absence of any symptom score, though in a I :2 potency ratio compared detrimental effect with the lower dose (I 600 pg day’). with MDI administration (6). More recently, a study In conclusion, this study demonstrates that BDP involving 26 adult asthmatics compared budesonide suspension for nebulization l600- and 3200 pg day’ 0.8 mg twice-daily administered by pMDl with spacer given by a nebulizer and BDP spray 800 pg day-1 given via and budesonide I mg and 4 mg twice-daily administered an MDI plus spacer have equivalent effects with respect by a Pari Inhaler Boy jet nebulizer, activated only during to the bronchoprovocation test, with a good safety and inspiration.The total mass output was similar from the tolerability profile. two devices, but their fraction of small particles differed by a factor of 2 in favour of pMDI. Effect was evaluated from daily home measurements of PEF need of p2- REFERENCES agonist, and symptom scores.A consistent trend showed I. Muers ME Overview of nebuliser treatment. Jhorox 1997; 52 the nebulizer treatment to be at least as efficient as the (Suppl 2): S25-30. pMDl plus spacer treatment. In actual fact, the apparent 2. Dennis JH, Hendrik DJ. Design characteristics for drug nebulizers. order of effect was 4 mg nebulized suspension treatment J Med Eng Jechnol 1992; 16: 63-68. 2 I mg nebulized suspension treatment > 0.8 mg pMDl 3. Mercer TT Production and characterisation of aerosols. Arch with spacer treatment (7). hem Med 1973: I3 I : 39-50. 4. Newman SP Delivery of therapeutic aerosols. Probs Resp Core The primary objective of this study was to determine 1988; I : 53-82. the effect of the treatments on FEV, in response to 5. Bisgaard H. Clinical efficacy of nebulized drugs./Aerosol Med 1994; methacholine challenge, with the bronchial provocation 7(Suppl I): s33-s37. test ratio being the main efficacy variable.The results of 6. Wilson AM, McFarlane LC, Lipworth BJ. Systemic bioactivity the methacholine test expressed as a ratio of PC,, after profiles of oral and nebulized budesonide in adult asthmatics. Chest 1998; I 14: IO22- 1027. 3 weeks’ treatment compared with the PC,, value 7. Bisgaard H, Nikander K, Munch E. Comparative study of before treatment, although not statistically significant budesonide as a nebulized suspension vs pressurized metered- (probably due to the small sample size in each treatment dose inhaler in adult asthmatics. Respir Med 1998; 92: 44-49.