UL/CSA LISTED

FANFAN && FIXTUREFIXTURE BOXESBOXES F ORA V ARIETYOF U SES

Arlington Choose the Fan or Fixture Box that’s right for you...... in Steel or Plastic – or a Combination!

FB405 Joist No matter what your needs – or Joist FBS405, FBS405T Each of our boxes is UL 6.0 cubic inches 6.0 cubic inches installation preferences, Arlington has a Mount Mount Listed to hold fans and fan/fixture box to fit. FBS407, FBS407T FB407 fixtures of a specific 8.0 cubic inches 8.0 cubic inches weight; generally from We manufacture a variety of steel and 35 to 200 lbs., non-metallic boxes in many depths and page FB412 14.4 cubic inches page depending on the box. cubic inch for NEW Joist 4 10 In addition, our non- capacities that CONSTRUCTION Plastic metallic boxes offer a install directly 2-hour fire rating. to the joist(s) Under-Joist FBS415 FB415 Press Hold for an extra- s 1-1/2" depth 10.3 cubic inches secure Center screw Mount Joist Mount screws into joist 14.6 cubic inches For ceilings up to 1-1/2" thck. installation. FB423 FBS420 Applications include: Joist 19.5 cubic inches Our boxes 2" depth n 1/2" or 5/8" drywall that mount to page 20.0 cubic inches FB426 16.0 cubic inches page n Double drywall the bottom of 5 For NEW 11 a joist deliver n Drywall mounted ss CONSTRUCTION a safe, secure Fan/Fixture bracket to hat channel, screws install installation or furring strips, into joist FBS415S For NEW FB442 Side Mount CONSTRUCTION Side Mount then to the joist because both 1-1/2" depth 13.4 cubic inches the box and the bracket install directly 14.6 cubic inches n Single or FB443 double joists to the joist! FBS420S 17.96 cubic inches 2" depth Plus, we have a box for every ceiling page 20.0 cubic inches condition! 5 FB444 25.6 cubic inches page FBS1423 For NEW and Existing 12 page14 23.0 cubic inches CONSTRUCTION For NEW Mounts CONSTRUCTION Side Mount Most of Arlington’s fan Between FBRS415 boxes ship with an installed 15.6 cubic Joists Steel& with Steel NM cable inches Adjustable Bracket connector, FBRS407R mud cover Brackets 8.0 cubic For RETROFIT in place inches Plastic and captive FB417S installation 20.0 cubic inches screws for both pages FBRS420R 2" depth Low profile page the box and the 20.0 cubic inches FB417SLP 13 fan/fixture mounting 6-7 20.0 cubic inches bracket.

For Any MB8 8'' Mounting FBRS420SC, FS420SCL 6.1 cubic inches Suspended 2" depth Block Ceiling Frame 20.0 cubic inches

page Arlington’s fan/fixture boxes are patented Arlington 8 Steel page14 (or other patents pending). 2 See chart on page 15 Uses • UL/CSA Load Ratings • Number of Single Conductors 3 Steel Boxes – Joist Mount Steel Boxes – Joist Mount

FBS405 Mount Under Joist FBS415 for 1/2" and 5/8" drywall Protective plastic tips 1-1/2" deep steel box FBS407 Installed FBS420 mud cover FBS415/ FBS420 for 5/8" drywall Mount under joist 2" deep steel box Captive Designed for 1/2" or 5/8" installation Captive Arlington’s octagonal steel screws bracket drywall ceilings, our cost- boxes mount directly to a joist remain installation effective, plated steel FBS405 in place screws for a strong, safe fan or fixture until used and FBS407 pan boxes installation. Available in two Installed NM mount directly to a ceiling cable connector depths (1-1/2" and 2"), and Box joist for a super-secure Green ground screw installation two styles. installation. screws (use to install Combination hex/Phillips head n For NEW CONSTRUCTION box UNDER joist) Install FBS415/FBS420 box under screws provide easy install- 1 the joist using the captive screws n UL Rated for 70 lb. fans; FBS405T from the break-off tab. ation with power screwdrivers. 200 lb. fixtures inside NO LOOSE PARTS! Box and bracket installation screws ship captive, and stay in place until FBS415 and FBS420 mount view Item # UPC/DCI/NAED Cubic Under Joist Unit/Std n CSA Rated for 50 lb. fan or you’re ready to use them. MFG #01 899 Inches Box Depth Pkg securely UNDER the joist. fixture Item # UPC/DCI/NAED Cubic Ceiling Unit/Std MFG #01 899 Inches Thickness Pkg FBS415 75204 14.6 1-1/2" 25 FBS405 76185 6.0 1/2", 5/8" 25 FBS420 75200 20.0 2" 25 n UL Rated for fans/fixtures up to 70 lbs. FBS407 76187 8.0 5/8" 25 * FBS405T 40500 6.0 1/2", 5/8" 25 n CSA Rated for 50 lb. fan or fixture * FBS407T 40700 8.0 5/8" 25 Side Mount * with threaded openings and #10 screws (supplied) for mounting Installed NM cable fan/fixture bracket. connector FBS415S NO LOOSE PARTS! Box and bracket installation screws ship 1-1/2" deep steel box captive, and stay in place until you’re ready to use them. FBS420S Bracket 2" deep steel box installation screws FBS415S and FBS420S mount on the SIDE of the joist.

Use these Item # UPC/DCI/NAED Cubic Side Mount Unit/Std Remove screws to MFG #01 899 Inches Box Depth Pkg Below installer removes cap- install box tive screws in preparation for these screws FBS415S 75206 14.6 1-1/2" 25 and use to ON SIDE of joist installing box to side of joist. FBS420S 75202 20.0 2" 25 FBS405 mount bracket

Secure installation! Box mounts Convenient. Drill (2) 1/8" dia. Easy. Mount bracket into the holes 1 directly to joist with captive screw 2 holes into joist through elongated 3 with the (2) long screws removed near center. openings on each side of box. previously. Mount fan/fixture per Remove the (2) screws noted manufacturer’s instructions. above. Use to mount the bracket...

n UL Rated for fans/fixtures Most of Arlington’s Fan/Fixture boxes ship with an installed NM cable up to 70 lbs. connector and mud cover – As well as captive installation screws for n CSA Rated for 50 lb. fan or the box and bracket. fixture

No parts to lose or misplace... Install FBS415S/FBS420S box on OPTION: Remove break-off tab Remove the bracket installation 1 the side of the joist using the (4) 2 with pliers. 3 screws noted above. Use them to they ship ready to use! captive screws removed from the mount fan/fixture bracket to the break-off tab. box. Arlington

4 See chart on page 15 Uses • UL/CSA Load Ratings • Number of Single Conductors 5 Plated Steel Boxes with fully adjustable mounting brackets Plated Steel Boxes with fully adjustable mounting brackets

For New Construction For Existing Construction FBRS415 Sled FBRS420R for New Construction 2 for Existing Construction FBRS420R Arlington’s super heavy-duty, plated steel fan/fixture n Mounts between joists or boxes, with fully adjustable As the hex bar is rafters 16" to 24" o.c 4 tightened, bracket mounting brackets, are the FBRS415 ends bite into the joists, n 20.0 cubic inch innovative alternative to 2 holding the unit secure. n UL Rated: existing bar hanger brackets. 1 35 lb. fans, Their heavy-duty construction Bracket Remove, and use these 50 lb. fixtures feet captive screws to install eliminates fan wobble. n CSA: Fans/fixtures fan/fixture bracket. up to 50 lbs. Plus, FBRS415 for new construction and FBRS420R, 3 Adjust box position FBRS407R for retrofit, ship between joists with this screw. ready to use, with all Item # UPC/DCI/NAED Cubic Use and Unit/Std MFG #01 899 Inches Box Depth Pkg mounting hardware secured Locator tab is pre-set to position in the assembly. There are no FBRS415 72250 15.6 New Construction 1/10 box properly on 1/2" ceiling Ceilings up to 1-1/4" thickness. bagged parts or pieces to lose.

n For ceilings up to 1-1/4" thick Cut hole in ceiling. Remove box Tighten the hex bar with a wrench Reattach box, and center it in hole. n Mounts easily, securely 1 from sled and fit mounting bracket 2 to secure bracket between joists. 3 Attach bracket with screws between joists 16" to 24" into hole. Position bracket supplied. Install fan/fixture per on-center (o.c.) between joists, with bracket feet manufacturer’s instructions. resting on the ceiling. n Versatile 16" to 24" o.c. positioning between joists For Wood I-Beams in Existing Construction n 15.6 cubic inch “Tooth” holds bracket temporarily in place. Remove screws from both ends of bracket. 1 2 Use them to attach bracket to joists. n UL Rated: Arlington’s FBRS407R fan/fixture FBRS407R Fans/fixtures: for Wood I-Beams up to 70 lbs. at 24" o.c. box is perfect for installations on in Existing Construction up to 110 lbs. at 16" o.c. Unique slide-style bracket wood I-beams or rafters. For a n CSA: Fans/fixtures secure, UL-Rated installation there’s up to 50 lbs. nothing better. n Box installs flush with ceiling drywall n Competitively priced! Note: Unlike other hard-to-assemble Drywall n For 1/2" and 5/8" thick installation brackets, Arlington’s unique slide- ceilings not shown style bracket offers fast and easy n No parts to lose – ships with installation. And you can position Adjust box position from 16" to 24" o.c. between Install fan mounting bracket. captive box adjustment 3 joists. 4 the box anywhere along the bracket screws, fan bracket installation screws and an Drywall cut away for a centered installation. to show installation installed NM cable between I-beams connector

n 8.0 cubic inch box

FBRS407R n For existing construction on wood I-beams or rafters set 16 to 24 inches on-center Item # UPC/DCI/NAED Cubic Use and Unit/Std MFG #01 899 Inches Box Depth Pkg n Listed to new UL standards

FBRS420R 75325 20.0 Retrofit 1/10 n UL rating CONVENIENT. Tab positions box FLEXIBLE. For flush ceiling installations A GREAT FINISH. FBRS415 flush 2" Box 35 lb. fan • 50 lb. fixture flush on 1/2" ceiling. Fits ceilings up on ceilings over 1/2" thick, bend the ceiling installation. to 1-1/4" thick. Bracket is scored for bracket along the scoreline that FBRS407R 72248 8.0 Retrofit on 1/10 Arlington ease of installation. matches the ceiling depth. Wood I-beams

6 See chart on page 15 Uses • UL/CSA Load Ratings • Number of Single Conductors 7 Fan/Fixture Box Kit for Suspended Ceilings Fixture Box for Suspended Ceilings

Designed just for mounting a Heavy-duty Plated Steel UL Listed for fixtures up to 50 lbs. Arlington’s new all-metal fan or fixture on a suspended Costs less than the 70 lb. rated FBRS420SC. box, just for fixtures, is a ceiling grid, Arlington’s Note: one-piece assembly that FS420SCL ships FBRS420SC fan/fixture box ships ready to install on a fully assembled and kit saves money! And 30 24" suspended ceiling grid – Meets NEW 2008 NEC, ready to install in the minutes of installation time. FS420SCL section 314.27 for Outlet Boxes t No assembly required. center of a 24" Patent pending ...box must support 23 kg The box/bracket assembly It’s tested and rated to (50 lb) luminaire suspended ceiling tile. ships with the box mounted To mount box support exit lights, security securely on-center, ready to off-center, loosen cameras – and other light install on a 24" grid. For a screws. Slide box into fixtures up to 50 lbs. centered installation, there’s position. No more guesswork. no need to adjust the box or 20.0 cubic inch Installers who previously bracket, but you can position capacity attached a metal box to a the box where you want it. Screws hold ends bracket in the field, then securely to ceiling grid There are no parts to lose! added a chain or wire for FBRS420SC ships fully support, now have an assembled. Installation and 2" deep box assembly that is fully tested adjustment screws ship to hold up to 50 lbs! parked in place. There’s an (photo taken from above ceiling) If the box is not perfectly installed NM cable connector (photo taken from positioned, loosen the too. above ceiling) appropriate screws, slide the n Fully adjustable mounting box along the bracket and bracket retighten the screws. n 2" deep, 20.0 cubic inch box Note: DROP WIRE n Easy, secure mounting to n Meets new UL standards MUST BE ceiling grid Note: CENTERED n UL Rating: 70 lb fan or CHAIN MUST OVER BOX. n Costs less than field- fixture BE CENTERED assembled components OVER BOX. CSA: Acceptable for fan Cut a 4-1/16" diameter hole in a Place box over hole. Snap ends of support bar over the (box, bracket, wire) support 1 24" ceiling tile. 2 3 ceiling grid (tees). Cut a 4-1/16" diameter hole in a Place box over hole. Place ends of Use the “S” hooks provided to attach n Saves installation time n Usable for Environmental 24" ceiling tile. support bar over the ceiling grid chain to turnbuckle, and chain to the 1 2 3 n Air Handling spaces (tees). overhead support. Use turnbuckle to Usable for Environmental apply tension to the chain, so it Air Handling spaces supports the weight of fan.

FBRS420SC Note: To Patent pending mount box t off-center, loosen screws. Adjustable Slide box into mounting bracket position.

20.0 cubic inch capacity Cable pulled through cable Use FS420SCL to install fixtures, security cameras, etc. 4 connector (not supplied). 5 Not fan rated. Captive installation and adjustment screws For FBRS420SC and Remove captive screws (shown FS420SCL above). Use them to install the fan Kit includes box/bracket assembly with turnbuckle, 12' heavy-duty chain, and (2) “S” hooks. Item # UPC/DCI/NAED Box Description Unit/Std 4 OPTION: If required by local or fixture per manufacturer’s MFG #01 899 Pkg code, use sheet metal screws specifications, NEC and all local Item # UPC/DCI/NAED Box Description Unit/Std FS420SCL 12526 2" deep Box for suspended 1/10 (not supplied) to hold bracket electrical codes. MFG #01 899 Pkg 20.0 cu. in. ceilings, for fixtures ends on ceiling grid. up to 50 lbs. FBRS420SC 75300 2" deep Fan/Fixture box kit 1/5 Arlington 20.0 cu. in. for suspended ceilings One-piece, rated unit includes box, bracket and drop wire

8 See chart on page 15 Uses • UL/CSA Load Ratings • Number of Single Conductors 9 Plastic Boxes Plastic Boxes - Press Hold • Joist Mount

FB405 NM cable FB415 connector for 1/2" and 5/8" drywall ships installed for 1/2" and 5/8" drywall FB407 in KO #1 FB426 To install box for 5/8" drywall securely on joist, for 1/2" and 5/8" drywall tighten captive FB412 center screw. FB423 for 1/2" or 5/8" drywall with FB426 for 1/2" or 5/8" drywall with hat channel or furring strips, FB407 Four hat channel or furring strips or double drywall gripping tangs with a single layer of drywall, ‘press hold’ or double drywall box to FB415 joist FB415 and FB426 come with FB405, FB407, and FB412 Screw Tunnels the screws you need to install offer the flexible, economical help to center FB405 the box on joist. the box and bracket, held solution to 1/2" and 5/8" KO #2 captive until you’re ready to drywall ceiling, with or FB412 use them. without hat channel or Shipped-in-place Underside furring strips. FB405 and center screw Press Hold...Speed, FB423 FB407 are perfect for double Convenience, Safety

joists or wood I-beams. Item # UPC/DCI/NAED Cubic Drywall Unit/Std MFG #01 899 Inches Thickness Pkg These boxes have gripping n Fast, easy installation tangs that press-hold the box NEW! Flanged design FB415 72167 10.3 1/2" or 5/8" 25 n Secure attachment forms a protective barrier FB426 72179 16.0 1/2" or 5/8" 25 to the joist while you reach for FB426F 12521 16.0 1/2" or 5/8" 25 to joist or rafter against air infiltration. your screwdriver. Tightening FB423 72190 19.5 1/2" or 5/8" * 25 n No parts to lose FB426F the center screw affixes the * w/ furring strips or hat channel with a single layer of drywall box onto the joist for a super- n 2-hour fire rating Box Installation or with a double layer of drywall secure installation. n UL Rated: 70 lb. fans, fixtures up to 200 lbs. FB415 n 2-hour fire rating

n CSA: Fans/fixtures n UL Rated: 70 lb. fans, up to 50 lbs. fixtures up to 200 lbs.

n CSA: Fans/fixtures up to 50 lbs.

Convenient. Gripping tangs hold Push NM sheathed cable through Remove (2) long parked screws. 1 box in place temporarily, until the 2 connector. 3 Use them to install bracket. FB412 FB412 center screw is tightened.

The FB412 fan/fixture box is perfect for 1/2" or 5/8" ...or double drywall (shown as cutaway). 1 drywall with 3/4" furring strips or hat channel with a 2 All of Arlington’s Fan/Fixture single layer of drywall... boxes ship with an installed NM cable connector and mud cover – as well as captive installation screws for the box and bracket. Item # UPC/DCI/NAED Cubic Drywall Unit/Std MFG #01 899 Inches Thickness Pkg Save time and FB405 72185 6.0 1/2" or 5/8" 25 No parts to lose or FB407 72177 8.0 5/8" 25 money with our FB412 72189 14.5 1/2" or 5/8" * 25 misplace...ready to use! The fan/fixture bracket installs Cable pulled through installed NM deeper, press-on * w/ furring strips or hat channel with a single layer of drywall 4 directly onto the joist through the 5 cable connector. fan/fixture boxes! Arlington or with a double layer of drywall oval slots in the box.

10 See chart on page 15 Uses • UL/CSA Load Ratings • Number of Single Conductors 11 Plastic Boxes Plastic Boxes with Steel Bracket

FB444 Nail On Attachment to Single or Double Joists FB417S Our largest capacity for ceilings L-shaped box up to 1-1/2" thick, FB442 including single-sheeted drywall mounted to furring FB443 Locator Post strips or hat channel – Lowest cost L-shaped boxes or double drywall FB442 Locator Post FB417SLP for bracket FB444 is the largest capacity installation Low profile for screws 1/2" or 5/8" ceilings box we make! Its 25.6 cubic Item # UPC/DCI/NAED Cubic Drywall Unit/Std inch capacity provides plenty MFG #01 899 Inches Thickness Pkg FB444 FB417SLP of room for wires – easy FB442 72194 13.4 1/2" or 5/8" 25 FB417S saves time! Nail on FB443 72197 17.96 1/2" or 5/8" 25 FB417S installation, and indicator access too! FB444 72187 25.6 1/2" or 5/8" 25 marks for 1/2", 5/8", and The slightly smaller FB443 FB442 Installation 3/4" ceiling thicknesses and FB442 offer the same make it the logical choice for great features and benefits at Single Joist Double Joist speedy attachment to single a lower cost. or double joists. n Boxes mount to single or double joists or rafters with For added convenience, use a shipped-in-place center the low profile FB417SLP for screw 1/2" or 5/8" ceilings. Also n Locator posts assure works for manufactured correct positioning of I-beams. bracket FB417S FB417S n UL Rated: 70 lb. fans, Both ship ready to use, with Secure! Side mount the box to the Pull wires. (Drywall installation Done! Install fan or fixture per fixtures up to 200 lbs. the nail in place and captive 1 joist using the shipped-in-place 2 omitted) After ceiling is installed, 3 manufacturer’s instructions. Fast. Simply nail the box to the joist. Indicator lines FB417S and FB417SLP side mount to single or center screw. remove captive installation screws n CSA: Fans/fixtures on FB417S assure proper positioning on the joist for double joists for a super-secure installation. bracket installation screws. – use them to install bracket. up to 50 lbs. FB444 Installation the ceiling thickness. n 2-hour fire rating Item # UPC/DCI/NAED Cubic Ceiling Unit/Std Most of Arlington’s n No loose parts – totally MFG #01 899 Inches Thickness Pkg Fan/Fixture boxes ship self-contained FB417S 72177 20.0 up to 1-1/2" 25 n Combination hex/Phillips FB417SLP * 72199 20.0 1/2" or 5/8" 25 with an installed NM cable head screws for easy * Also works on manufactured I-beams connector and mud cover installation with power screwdrivers – As well as captive n Nail on installation installation screws for n 20.0 cubic inch the box and bracket. n 2-hour fire rating Fast and easy installation on single or Accurate! Locator posts on these L-shaped boxes 1 double joists! 2 assure proper positioning of the installation bracket. n UL Rated: Fans/ No parts to lose or fixtures up to 70 lbs. n CSA: Fans/fixtures misplace... ready to use! up to 50 lbs.

Easy. Bracket installation on FB444. Easy access. FB444 OPTION: To restuff wires, open Arlington 3 (Drywall installation not shown) 4 bottom of the box – before drywall installation.

12 See chart on page 15 Uses • UL/CSA Load Ratings • Number of Single Conductors 13 8'' Mounting Block with built-in box for fan and fixture installations Fan/Fixture Boxes

MB8 MB8 includes... Fan/Fixture Box Rating and # of Single Conductors 6.1 Cubic inches Two #10 x 3" wood screws, one #8 x 1-1/2" wood screw, two KOs, and one NM94 non-metallic cable connector. UL CSA UL Fixture CSA Fixture n Ceiling medallion and Catalog Category Cubic Fan Load Fan Load Static Static # Of Single Conductors electrical box combined Number Inches Rating Rating Rating Rating #14 or #12 or #10 Item # UPC/DCI/NAED Cubic Use and Unit/Std n (Lbs.) (Lbs.) (Lbs.) (Lbs.) Supports flood lights, MFG #01 899 Inches Box Depth Pkg smoke detectors, fans, light fixtures – any fixture MB8 42330 6.1 Flat Mount 1/10 FB405 PLASTIC 6.0 70 50 200 50 3—— needing a safe, strong FB4050 PLASTIC 6.0 70 50 200 50 3—— installation. FB407 PLASTIC 8.0 70 50 200 50 433 n UV rated plastic MB8 Installation FB4070 PLASTIC 8.0 70 50 200 50 433 n For interior or exterior use FB412 PLASTIC 14.4 70 50 200 50 765

n Mounts directly to soffit or FB415 PLASTIC 10.3 70 50 200 50 544 Joist ceiling joist without the FB4150 PLASTIC 10.3 70 50 200 50 544 need to cut ceiling drywall FB417S PLASTIC & STEEL 20.0 70 50 70 50 10 88 n Paintable FB417SLP PLASTIC & STEEL 20.0 70 50 70 50 10 88 n UL Rated: 70 lb. fan, 200 lb. FB423 PLASTIC 19.5 70 50 200 50 987 fixture; CSA rated: 50 lb. fan/fixture FB426 PLASTIC 16.0 70 50 200 50 876 FB426F PLASTIC 16.0 70 50 200 50 876 Canadian orders ship with Locate the ceiling joist using a stud Using the #8 x 1-1/2" wood screws Install the fixture or fan mounting grounding lug required by 1 finder or similar device. Drill a hole 2 provided, mount the MB8 to the 3 bar (provided with the fixture or FB442 PLASTIC 13.4 70 50 200 50 644 approximately 1/2" in diameter, in joist (through the ceiling). fan) directly to the joist with the CSA for use with fixtures. PLASTIC the ceiling next to the joist. (2) #10 x 3" wood screws and lock FB443 17.96 70 50 200 50 877 Remove desired knockout. Insert washers provided. Wire the fixture FB444 PLASTIC 25.6 70 50 200 50 13 11 10 the cable connector into the or fan following the instructions opening. Pull the NM cable included with the product. FB450 PLASTIC 14.5 70 50 200 50 765 through the connector. FB900 PLASTIC 14.5 70 50 200 50 765 FBRS407R STEEL 8.0 35 50 50 50 433 NEW! Steel Box – Side Mounts to Joist FBRS415 STEEL 15.6 70 @ 24" o.c. 50 70 @ 24" o.c. 50 766 110 @ 16" o.c. 110 @ 16" o.c. FBS1423 Three screws ship captive FBRS420R STEEL 20.0 35 50 50 50 10 88 23.0 Cubic inches Tapped #8-32 and attach box securely to STEEL (for fixtures) the joist. FBRS420SC 20.0 35 50 50 50 10 88 FBS1423 STEEL 23.0 70 50 70 50 11 10 9 Designed for new FBS405 STEEL 6.0 70 50 200 50 3—— construction or retrofit, this Tapped #10-32 FBS405T STEEL 6.0 70 50 200 50 3—— deep steel box side mounts Tapped for fans #10-32 for fans (screws included) FBS407 STEEL 8.0 70 50 200 50 433 to a joist for a super secure, (screws included) fan-rated installation. FBS407T STEEL 8.0 70 50 200 50 433 FBS415 STEEL 14.6 70 50 200 50 766 n UL Rated for fans/fixtures up Installed STEEL to 70 lbs. NM cable FBS415S 14.6 70 50 70 50 766 connector FBS1423 FBS420 STEEL 20.0 70 50 200 50 10 88 n CSA: Fans/fixtures Patent Pending up to 50 lbs. FBS420S STEEL 20.0 70 50 70 50 10 88 3/4" KO FBX900 PLASTIC & STEEL 14.5 70 50 70 50 765 on side FS420SCL STEEL 20.0 ——25 25 10 88 Tapped #8-32 MB8 PLASTIC 6.1 70 50 200 50 3—— (for fixtures)

Most of of Arlington’s Fan/Fixture boxes ship Place box at proper depth; with an installed NM cable connector and mud Item # UPC/DCI/NAED Cubic Side Mount Unit/Std cover – As well as captive installation screws attach to joist with three MFG #01 899 Inches Box Depth Pkg for the box and bracket. captive screws in the box. FBS1423 76190 23.0 2.375" 10 No parts to lose or misplace...ready to use! Arlington Arlington 14 15 SAVE MONEY! FLUSH WITH CEILING FAN/FIXTURE BOX just for SUSPENDED CEILINGS FAN/FIXTURE BOX with ADJUSTABLE BRACKET

pg 8 Save 30 minutes of assembly time with FBRS415 pg 6 Arlington’s heavy-duty, plated steel Arlington’s new fan/fixture box. It ships Patent pending fan/fixture box has an adjustable with the box and bracket assembly bracket that fits 16" to 24" o.c. mounted on center, ready to install on a Flush ceiling installations! 24" suspended ceiling grid. FBRS415 is designed for ceilings up to 1-1/4" thick. • No parts to lose For 1/2" ceilings, use the pre-bent positioning tab.

• Installation and adjustment screws FBRS415 ship captive Patent pending • 2" deep, 20.0 cu. inch box

For other ceiling NEW! thicknesses, bend along the UL rating appropriate Fan/Fixture score line. FBRS420SC 70 lb at 24" o.c. Patent pending 110 lb at 16" o.c. • 15.6 cu. inch box • Ships with captive screws, mud cover, installed NM cable connector

(from above ceiling grid)

UL rating 70 lb fan or fixture Adjust Attach box to joists position

TESTED WEIGHT RATING FIXTURE BOX LISTED AS 1-PIECEUNIT for SUSPENDED CEILINGS pg 9

FS420SCL Arlington’s new all-metal, one-piece fixture box ships ready to install on a 24" suspended ceiling grid. There’s no assembly required!

It’s tested and rated to support exit lights, security cameras and other light fixtures up to 50 lbs.

No more guesswork. Installers who attached a metal box to a bracket in Mounts fixtures securely the field, then added a chain or wire for support, now have an assembly Arlington to the ceiling grid that’s fully tested to hold up to 50 lbs! FS420SCL is UL/CSA Listed as a complete unit: box, bracket, drop wire.

1 Stauffer Industrial Park • Box can be positioned anywhere along bracket Scranton, PA 18517 800/233.4717 • Costs less than field-assembled components (box, bracket, wire) Fax 570/562.0646 www.aifittings.com • Usable for Environmental Air Handling spaces

©2008 Arlington Industries, Inc. Distributed by

Arlington’s fan/fixture boxes are patented (or other patents pending). 16