Quick viewing(Text Mode)

Test Report No. 70.405.19.4513.01R1 Dated 2019-03-19 ORIGINAL

Test Report No. 70.405.19.4513.01R1 Dated 2019-03-19 ORIGINAL

Test Report No. 70.405.19.4513.01R1 Dated 2019-03-19 ORIGINAL Applicant : Taya Canvas () Company Limited Address : No 777, Fengguan Road Industrial Park, Jinshan Shanghai China Post Code: 201501

Sample description : Spiderweb 300 Color : White End Use : Curtain

Receipt date of sample : Received on 2019-02-25 Date of testing : From 2019-02-25 to 2019-03-18 Sample submitted : The sample(s) was (were) submitted by applicant and identified. Test result : Refer to next page.

Description of the test subject Sample Description Photo

001 Spiderweb 300

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch Testing Center Prepared by: Authorized by:

______Nick Shen Elyn Yao Softlines Department Softlines Department

Note: (1)The TÜV SÜD Certification and Testing (China) Co., Ltd.“General Terms & Conditions” applied. For full version, please visit: http://www.tuv-sud.cn/cn-scn/terms-and-conditions (2)The results relate only to the Items tested,(3)The test report shall not be reproduced except in full without the written approval of the laboratory

Laboratory: Phone: +86 21 6037 6300 Regd. Office: TÜV SÜD Certification and Testing (China) Co., Fax: +86 21 6037 6350 TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Ltd. Shanghai Branch Testing Center E-mail: [email protected] Branch Testing Center Softlines Lab Softlines Lab www.tuv-sud.cn/softlines 2F Building B, No. 1999 Du Hui Rd, Minhang District, Shanghai 201108 P.R. China Page 1 of 3 Test Report No. 70.405.19.4513.01R1 Dated 2019-03-19 ORIGINAL

Conclusion Test Items 001 1. DIN 4102-1:1998 Fire behaviour of building materials and elements Part 1: Classification of building materials requirements and testing Pass -B1 Requirement

Remarks: Pass = Meet General Requirement Fail = Below General Requirement * = No Specified Requirement # = No Comments N/A = Not Applicable - = Not Conducted

Disclaimer Measurement Uncertainty: Unless otherwise agreed upon, Pass or Fail verdicts are given based on the measured values without any considerations of measurement uncertainties. Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements. By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

Test Results

1. DIN 4102-1:1998 Fire behaviour of building materials and elements Part 1: Classification of building materials requirements and testing Sample 001 All materials, except flooring, may be classed as B1 materials if they: ‘ ’ B1 requirement: - Withstand the test specified in DIN 4102-16 using the Brandschacht apparatus specified in DIN 4102-15, and - meet the requirements for class B2 materials. This test shall be deemed passed if, for any of the five specimens tested, flaming does B2 requirement: not reach the gauge mark within 20 seconds after flame application.

Test method: 1.DIN 4102-16 Fire behaviour of building materials and elements – ‘Brandschacht’ tests Sample size 190mm*1000mm Parameter Test result Requirement The minimum remaining 610 •0 length of burning (mm) The average remaining 620 •150 length of burning (mm) The maximum average flue 128 ” 200 gas temperature peaks(ć)

According to the test results, the submitted sample meets the requirements of DIN 4102- Conclusion: 16 requirement.

Laboratory: Phone: +86 21 6037 6300 Regd. Office: TÜV SÜD Certification and Testing (China) Co., Fax: +86 21 6037 6350 TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Ltd. Shanghai Branch Testing Center E-mail: [email protected] Branch Testing Center Softlines Lab Softlines Lab www.tuv-sud.cn/softlines 2F Building B, No. 1999 Du Hui Rd, Minhang District, Shanghai 201108 P.R. China Page 2 of 3 Test Report No. 70.405.19.4513.01R1 Dated 2019-03-19 ORIGINAL

2. DIN 53438: Response to ignition by a small flame Sample details Edge ignition: 5 pieces 90mm*190mm Sample size Surface ignition:5 pieces 90mm*230mm

Temperature Relative humidity Duration Conditioning 23±2°C 50±5%R.H. 24h

Test result Test item No. Whether flaming reach the gauge mark within 20 seconds after flame application(Yes/No) 1 No 2 No Edge ignition 3 No 4 No 5 No 1 No 2 No Surface ignition 3 No 4 No 5 No

Conclusion According to the test results, the submitted sample comply the requirements of DIN 4102-1 B2 requirement.

Overall Conclusion According to the test results, the submitted sample comply the requirements of DIN 4102-1 B1 requirement.

Remark: This Report is to Supersede Test Report No.70.405.19.4513.01 Issued on 2019-03-18.

-End of Test Report-

Laboratory: Phone: +86 21 6037 6300 Regd. Office: TÜV SÜD Certification and Testing (China) Co., Fax: +86 21 6037 6350 TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Ltd. Shanghai Branch Testing Center E-mail: [email protected] Branch Testing Center Softlines Lab Softlines Lab www.tuv-sud.cn/softlines 2F Building B, No. 1999 Du Hui Rd, Minhang District, Shanghai 201108 P.R. China Page 3 of 3