Application Data Sheet ADS 2600-02/rev.B and Industry May 2008

Digester Control in the

BACKGROUND Any monitoring system used in this service must with- The process is particularly efficient stand the hot, highly caustic liquid at pressures over because it involves continuous recycling of raw mate- 1700 kPa (246 psig). The /pulp mixture is a rials. chips are delignified by harsh chemicals thick, viscous slurry that tends to coat and clog system () to produce pulp and spent liquor (black piping, especially if allowed to cool. Automatic titrators liquor). The spent liquor is later regenerated to white have been designed for use under these conditions liquor in the causticizer. but are hard to maintain and require extractive (“grab”) sampling. Grab samples may not reflect actual The most important physical parameter of pulp conditions because the time delay required for production is the , which essentially analysis allows other reactions to occur. The toroidal indicates how well the chips have been cooked. conductivity method is ideal for this kind of physical Con-trolling the value of the Kappa number is difficult environment. because the original wood chips may differ greatly in composition and moisture content. Measuring conduc- tivity in the upper (or sometimes lower) recirculation TOROIDAL CONDUCTIVITY zone of a continuous digester can provide control Rosemount Analytical recommends using toroidal feedback and lower variability in the Kappa number of conductivity to measure alkali concentration in black the product pulp. liquor because the sensors have proven rugged and reliable with a minimum of maintenance. Although PROCESS: CHEMISTRY OF PULP DIGESTION conductivity is non-specific and all ionic species will interfere somewhat, the active components NaOH and A continuous digester has a constant charge of Na2S are the strongest contributors to the total. Other wood chips and a given flow rate of white liquor components are considerably lower in conductivity (basically NaOH and Na2S). The digester fluid is heated and any sudden increase in unreacted alkali concen- to approximately 180°C (356°F) to accelerate the tration will be easily noticed. Conduc-tivity can be delignification reaction. The NaOH (caustic) is measured either at the product outlet or in the upper consumed by the acetic and components in the recirculation zone for rapid response to process wood to yield sulfates and carbonates: changes. Figure 1 shows both of these locations.

Na2S + NaOH + wood chips —>Na2SO4 + Na2CO3 + pulp Alkali concentrations are usually measured by wet (white liquor) (black liquor) chemical tests called ABC titrations. One test As residence time in the digester increases, the yield measures the sum of NaOH and Na2S, which is called of pulp increases, but overcooking can degrade the Active Alkali. Another test measures NaOH and one strength of the pulp. The pulp is later separated from half the Na2S, which is called Effective Alkali. These the black liquor and washed to reclaim the valuable two quantities are related by the sulfidity, the chemicals. percentage of alkali present in the form. Since sulfidity typically changes little in most processes, The traditional method of controlling the Kappa number conductivity can by correlated to both Active or is to monitor the residual caustic in the black liquor and Effective Alkali with the addition of a constant sulfidity infer how much has reacted in the digester. A conduc- correction. tivity measurement at this location is thus correlated with an acceptable Kappa number range, and the feed rate of white liquor to the digester is adjusted to hold this conductivity value. INSTALLATION OPTIONS Rosemount Analytical has three separate sensor Compatible toroidal conductivity analyzers include the options for this application. The Model 242 flow- Model 5081-T and Xmt-T DC-powered HART and through sensor is flanged and uses a PEEK or ceramic FOUNDATION Fieldbus analyzers, the Model 1056-21 liner for maximum chemical resistance. The retractable analyzer, and the Model 54eC HART analyzer/con- Model 228 sensor has a unique lead screw design that troller. The Model 5081-T is housed in a robust explo- allows safe retraction through a ball valve at up to 2030 sion-proof enclosure that is especially suited to the kPa (295 psig). harsh environment. The Model 54eC is com- patible with both toroidal and contacting conductivity The Model 226 Sensor, with its 4.75 cm (1.87 in.) bore, sensors for optimum versatility in the field. Consult the can be used when large solid particles are present and appropriate Product Data Sheet for complete details. can also be adapted for flange mounting.

INSTRUMENTATION

Model 5081-T Two-wire Conductivity Model 54eC Conductivity Analyzer Transmitter • Measures Conductivity, Resistivity, or Percent • Automatic/Manual temperature compensation (%) Concentration. to ensure accurate monitoring and control. • Uses either contacting or inductive sensors to • Hand-held Infrared Remote Control (IRC) link meet most application requirements. to activate all transmitter functions. • Optional TPC and PID control capability. • AMS compatible. • Fully Descriptive Diagnostic Messages and easy-to-use inter- face spells out each operation in English, French, German, Italian, or Spanish. Model 228 Retractable Toroidal • Two Independent Outputs for conductivity and temperature. Conductivity Sensor • Three alarms with Programmable Logic, plus one dedicated fault alarm. • Convenient isolation of sensor for cleaning or replacement. • Easy insertion/retraction of sensor. Model 242 Flow-Through Toroidal • Flush ports on assembly chamber to allow sensor cleaning. Conductivity Sensor • Now available in 4" pipe size. • Toroidal measurement principle greatly Model 226 Toroidal Conductivity reduces sensor fouling. Sensor • Automatic temperature compensation with inte- • Toroidal (inductive) principle of measurement gral RTD. greatly reduces sensor fouling problems. • Externally-mounted toroids are protected from harsh process- • Chemically-resistant materials withstand the effect of highly es. corrosive solutions. • Modular design allows liner replacement without sensor • Large-bore design prevents plugging by solid particles. replacement.

2 Rosemount Analytical WHITE LIQUOR

CHIPS ) ) ) ) ) ) ) ) )

BLACK LIQUOR AND PULP

FIGURE 1. Kraft Digester Control

Rosemount Analytical 3 The right people, the right answers, right now.