Controller Installation Manual MOTION CONTROL ENGINEERING, INC. 11380 WHITE ROCK ROAD RANCHO CORDOVA, CA 95742 TELEPHONE (916) 463-9200 FAX (916) 463-9201 CONTROLLER INSTALLATION MANUAL HMC-1000 Series PHC Programmable Hydraulic Controller PART # 42-02-1P00 REV. H.4 DECEMBER 2008 TABLE OF CONTENTS IMPORTANT PRECAUTIONS AND NOTES .................................. ix SECTION 1 PRODUCT DESCRIPTION 1.0 General Information ...............................................1-1 1.1 Car Controller Physical Description ...................................1-2 1.2 Car Controller Functional Description..................................1-7 1.2.1 Car Operation Control (COC)..................................1-7 1.2.2 Car Communication Control (CCC) ..............................1-9 1.2.3 Programming and Diagnostics Tools ............................1-9 1.2.4 Duplexing.................................................1-9 1.3 Landing System Control Box ........................................1-9 SECTION 2 INSTALLATION 2.0 General Information ...............................................2-1 2.0.1 Site Selection..............................................2-1 2.0.2 Environmental Considerations .................................2-1 2.0.3 Recommended Tools and Test Equipment ........................2-2 2.0.4 The Wiring Prints ...........................................2-2 2.1 Controller Installation..............................................2-3 2.1.1 Controller Wiring Guidelines...................................2-3 2.2 General Wiring Guidelines ..........................................2-4 2.2.1 Ground Wiring .............................................2-4 2.2.2 Main AC Power.............................................2-5 2.2.3 Pump Motor Wiring..........................................2-5 2.3 Hoistway Control Equipment Installation ...............................2-5 2.3.1 Installing the Landing System ..................................2-5 2.3.2 Installing the Hoistway Limit Switches ...........................2-5 2.3.3 Installing the Landing System Control Box (LS-QUTE) ...............2-6 2.3.4 Installing the Magnetic Strips on the Steel Tape ....................2-6 2.3.5 Installing the Magnetic Strips on the Steel Tape ....................2-7 42-02-1P00 TABLE OF CONTENTS • i SECTION 3 START-UP SEQUENCE 3.0 General Information ............................................... 3-1 3.1 Ground Check ................................................... 3-1 3.2 Before Applying Power.............................................3-1 3.3 Applying Power .................................................. 3-2 3.3.1 Initial Adjustments and Power Phasing........................... 3-2 3.3.2 Moving the Elevator on Inspection.............................. 3-3 3.3.3 Preparing the Car to Run on Automatic Operation.................. 3-3 3.4 Preparation for Final Adjustment ..................................... 3-4 SECTION 4 FINAL ADJUSTMENT 4.0 General Information ............................................... 4-1 4.1 Running on Automatic Operation ..................................... 4-1 4.1.1 Diagnostic Messages and Input/output Signals .................... 4-1 4.1.2 A Few Words about Absolute Floor Encoding ..................... 4-2 4.1.3 Registering Car Calls........................................ 4-3 4.1.4 Test Mode Operation........................................ 4-3 4.1.5 Switching to Automatic Operation............................... 4-4 4.2 Final Adjustments ................................................ 4-4 4.2.1 Door Operator Adjustments................................... 4-4 4.2.2 Hydraulic Valves............................................ 4-4 4.2.3 Slowdown and Limit Switches.................................. 4-5 4.2.4 Hall Calls ................................................. 4-5 4.2.5 Options................................................... 4-5 4.2.6 Door Open/close Protection ................................... 4-5 4.2.7 Motor Limit Timer........................................... 4-5 4.2.8 Valve Limit Timer........................................... 4-5 4.2.9 Stuck Button Protection ...................................... 4-5 4.2.10Relevel Operation........................................... 4-5 ii • TABLE OF CONTENTS 42-02-1P00 SECTION 5 THE COMPUTER 5.0 About the PHC Series .............................................5-1 5.1 The MC-PCA Computer Panel.......................................5-1 5.1.1 Indicators .................................................5-1 5.1.1.1 Computer on Light ....................................5-1 5.1.1.2 Vertical Status Indicator Lights ..........................5-1 5.1.1.3 Diagnostics LCD Display...............................5-2 5.1.2 Switches, Buttons & Adjustments...............................5-2 5.1.2.1 Computer Reset Pushbutton............................5-2 5.1.2.2 N, S, +, & - Pushbuttons ...............................5-2 5.1.2.3 Mode Selection F1-F8 Function Switches ..................5-3 5.1.2.4 LCD Contrast Adjustment Trimpot........................5-3 5.1.3 Terminals.................................................5-3 5.1.3.1 Power Supply Terminal ................................5-3 5.1.3.2 Communication Port for Duplexing .......................5-3 5.1.3.3 Com Port 1 and 2 .....................................5-3 5.1.4 Status Displays.............................................5-3 5.2 Computer Security................................................5-3 5.2.1 Password.................................................5-4 5.3 Diagnostic Mode .................................................5-4 5.3.1 Getting into Diagnostic Mode..................................5-4 5.3.2 Function of N Pushbutton.....................................5-4 5.3.3 Function of S Pushbutton.....................................5-5 5.3.4 Function of + Pushbutton.....................................5-5 5.3.5 Function of ! Pushbutton.....................................5-5 5.3.6 Format of Lcd Display........................................5-5 5.3.6.2 Status Message......................................5-6 5.3.6.3 Elevator Position .................................... 5-13 5.3.6.4 Computer Internal Memory............................. 5-13 5.3.7 Troubleshooting Using the Computer's Internal Memory ............ 5-15 5.3.8 Troubleshooting Specific Problems ............................ 5-17 5.3.8.1 Problem: the BFD/TFD Error Message Is Flashing on the Display5-17 5.3.8.2 Problems with Calls.................................. 5-19 5.3.8.3 Problems with Doors................................. 5-19 5.3.9 Setting Parameters (Options) to Default Values................... 5-19 42-02-1P00 TABLE OF CONTENTS • iii 5.4 Program Mode.................................................. 5-20 5.4.1 General Description of Program Mode .......................... 5-20 5.4.1.1 Viewing Menus on the LCD Display...................... 5-20 5.4.1.2 Viewing Options Within a Menu ........................ 5-21 5.4.1.3 Changing a Value ................................... 5-21 5.4.1.4 Saving the New Values............................... 5-21 5.4.1.5 Restoring Original Values ............................. 5-22 5.4.1.6 Step-by-step Example................................ 5-22 5.4.2 Basic Feature Menu Options ................................. 5-23 5.4.2.1 Simplex or Duplex?.................................. 5-23 5.4.2.2 Operation (Dispatching Operation) ...................... 5-23 5.4.2.3 Top Landing Served? ................................ 5-23 5.4.2.4 Car Doors Are Walk-thru?............................. 5-23 5.4.2.5 Car Serves Frnt/flr 1? ................................ 5-23 5.4.2.6 Car Serves Rear/flr 1?................................ 5-23 5.4.2.7 Parking Floor....................................... 5-24 5.4.2.8 Alt. Parking Floor.................................... 5-24 5.4.2.9 Secondary Parking Floor.............................. 5-24 5.4.2.10 Lobby Floor....................................... 5-24 5.4.2.11 Car Identifier ...................................... 5-24 5.4.2.12 Number of IOX Boards? ............................. 5-24 5.4.2.13 Number of I4O Boards?.............................. 5-24 5.4.2.14 Number of AIOX Boards? ............................ 5-24 5.4.3 Fire Service Menu Options................................... 5-24 5.4.3.1 Fire Service Operation?............................... 5-24 5.4.3.2 Fire Phase 1 Main Floor .............................. 5-24 5.4.3.3 Fire Phase 1 Alt. Floor................................ 5-24 5.4.3.4 Fire Svce. Code..................................... 5-25 5.4.3.5 Fire Phase I 2nd Alt. Floor............................. 5-25 5.4.3.6 Bypass Stop Sw. On Phase 1?......................... 5-25 5.4.3.7 Honeywell Fire Operation? ............................ 5-25 5.4.3.8 New York City Fire Phase 2 and ANSI 89? ................ 5-25 5.4.3.9 White Plains, NY Fire Code? ........................... 5-25 5.4.3.10 Mass 524 CMR Fire Code? ........................... 5-25 5.4.4 Door Operation Menu Options................................ 5-25 5.4.4.1 Nudging?.......................................... 5-25 5.4.4.2 Stuck Photo Eye Protection?........................... 5-26 5.4.4.3 Sequential Door Oper. (F/R)? .......................... 5-26 5.4.4.4 Car Call Cancels Door Time? .......................... 5-26 5.4.4.5 Nudging During Fire Ph. 1?............................ 5-26 5.4.4.6 Retiring Cam Option? ................................ 5-26 5.4.4.7 Pre-opening? ....................................... 5-26 5.4.4.8 Mechanical Safety Edge? ............................
Recommended publications
  • Schindler Schindler / Westinghouse Quick Locator Guide
    www.SEESinc.com SCHINDLER/WESTINGHOUSE SCHINDLER / WESTINGHOUSE QUICK LOCATOR GUIDE Belts . 607 Brushes . 608-611 Brush Holders . 612-613 Capacitators. 630 Car Signal Components . 600-606 Gongs . 606 Emergency Stop Switch . 600, 602-603 Key Switches and Keys . 600, 604, 606 Lantern Lens. 605 Position Indicators . 604 Pushbutton Assemblies . 600-603, 606 Switches, Rocker and Reed. 606 Coils . 614-616 Door Parts And Equipment . 617-629 Cables and Pulleys . 628-629 Door Keys and Escutcheons . 625 Door Roller Assemblies. 628 Gibs, Guides . 625, 656 Hatch Equipment . 619 Interlock Components . 617, 620-622 Door Motors . 619, 629 Operators . 626-627 Safety Edge Parts . 623 Spirator, Reel Closer . 624 Track Liner . 629 Electronics - Tubes, Breakers, Fans . 631 Machine Parts . 632-636 Gaskets, Seals and Bearings. 632-636 Motors . 619, 629, 647 Printed Circuit Boards . 637-641 Rectifiers . 630 Relays . 643-644 Relay Components. 644-648 Resistors. 642 Selector Components . 649-650 Switches . 648-650 Transformers . 651 Wheels And Rollers . 652-655 Hanger Assemblies. 653-654 Hanger Rollers . 653-654 Roller Guide Assemblies . 655 Roller Guide Wheels . 654-655 954.971.1115 / fax 954.917.7337 800.526.0026 599 www.SEESinc.com Car Signal Components SB-2 SB-3 SB-4 SB-1 SCH-KCY-001 SCH-KCY-002 SB-5 SB-6 SB-6-VAN SB-1BR-7 SK-1 SKS-2A SKS-1 SK-3 SK-4 SK-5 SKS-2 SK-2 S.E.E.S. # O.E.M. # Description SB-1 8544C17G04 Button Housing, with lens SB-1BR- 6954C71H01 Braille Plate, braille for SB-1 housing, Stainless Steel, 1” x 1.187” SCHINDLER/WESTINGHOUSE (specify marking) SB-1BR-ARROW_DOWN Braille, Down Arrow For SB-1 SB-1BR-ARROW_UP Braille, Up Arrow For SB-1 SB-2 8540C58H02 Button Retainer Bracket SB-2A 70010CSC3R Screw, 6-32 x 1/2" Hex Washer Head, Slotted SKS-3 SB-3 7283C730G02 Printed Circuit Board Assembly for pushbutton, two micro switch type SB-4 7283C730G01, Printed Circuit Board Assembly for pushbutton, one 998C278H11 micro switch type SCH-KCY-001 D3158-057A/AS100 Key Switch, PHI, 3 position with AS100 key SCH-KCY-002 D3158-057B/AS100 Key Switch, PHII, 3 pos, AS100 key, per yr.
    [Show full text]
  • Switches and Relays for the Power Industry
    Switches and Relays For the Power Industry E L E C T R O NEVER S W I T A DOUBT C H U T I L I T Y ELECTROSWITCH Corporation 180 King Avenue P Weymouth, MA 02188 R TEL: (781) 335-5200 O FAX: (781) 335-4253 www.electroswitch.com D U C T S 5M 113 Printed in USA U.2.D THE ELECTRO SWITCH CORPORATion Family… PROVIDING INTELLIGENT SOLUTIONS FOR SWITCHING AND CONTROL Complete line of electrically and manually activated Rotary Switches and Relays POWER SWITCHES & RELAYS for electric utility, defense, and industrial monitoring and control applications The Best Rotary Switches, Relays, and Electrical Systems Products... Backed by the industry’s most www.electroswitch.com knowledgeable and responsive Rotary Switches; Miniature Toggle, Paddle, Rocker, Power Toggle, and Push- ELECTRONIC PRODUCTS Button Switches; Hall Effect, and Mechanical Encoders; Illuminated Switch engineering and customer Products; and Power Transformers service professionals... Any way you want them... Delivered when you need them. www.electro-nc.com DIGITRAN Digital and Rotary Switch Products designed for aviation, defense, and industrial DIGITAL & ROTARY SWITCHES switch applications ELECTROSWITCH www.digitran-switches.com ARGA CONTROLS Electric utility, industrial and military-grade Power Meters, Battery Monitors, MEASUREMENT & CONTROL INSTRUMENTATION and Transducers for precision measurement applications NEVER www.argacontrols.com Sunrise Technologies Wireless Communication Systems for Smart Grid applications and a complete A DOUBT OUTDOOR LIGHTING CONTROLS & MONITORING line
    [Show full text]
  • Moeller Wiring Manual 02/05 Specifications, Formulae, Tables
    Moeller Wiring Manual 02/05 Specifications, Formulae, Tables Page Marking of electrical equipment 9-2 Circuit symbols, European – North America 9-14 Circuit diagram example to North American specifications 9-27 Approval authorities worldwide 9-28 Test authorities and approval stamps 9-32 Protective measures 9-34 Overcurrent protection of cables and conductors 9-43 Electrical equipment of machines 9-51 Measures for risk reduction 9-56 Measures for risk avoidance 9-57 Degrees of protection for electrical equipment 9-58 North American classifications for control switches 9-68 9 Utilisation categories for contactors 9-70 Utilisation categories for switch-disconnectors 9-74 Rated motor currents 9-77 Conductors 9-81 Formulae 9-90 International unit system 9-94 For Immediate Delivery call KMParts.com at (866) 595-96169-1 Moeller Wiring Manual 02/05 Specifications, Formulae, Tables Marking of electrical equipment General Extracts from the DIN Standards with VDE The marking appears in a suitable position as Classification are quoted with the permission of close as possible to the circuit symbol. The the DIN (Deutsches Institut für Normung e.V.) and marking forms the link between the equipment in the VDE (Verband der Elektrotechnik Elektronik the installations and the various circuit documents Informationstechnik e.V.) It is imperative for the (wiring diagrams, parts lists, circuit diagrams, use of the standards that the issue with the latest instructions). For simpler maintenance, the date is used. These are available from complete marking or part of it, can be affixed on VDE-VERLAG GMBH, Bismarckstr. 33, 10625 or near to the equipment.
    [Show full text]
  • How to Use Rotary Stepping Switches Wisely and Fig
    $1.45 ROTARY HOW TO USE STEPPING SWITCHES Photographs on the front and back cover are of AE's Type 45 Rotary Stepping Switch Today's rotary stepping switches are wired for hermetic seaJing. the result of decades of service usage and experience. Here, in one book, are the major "DO's" and "DON'T's" of their successful application. AUTOMATIC ELECTRIC Subsidiary 01 GENERAL GENERAL TELEPHONE & ELECTRONICS ~ C·1057-40M -3· Merit Printed in the U.S.A. TCI Library: www.telephonecollectors.info TCI Library: www.telephonecollectors.info II 1- HOW TO USE ,. ROTARY STEPPING SWITCHES V. E. JAMES, Editor Ii· i !I ! I' \ 1 ! r • AUTOMATIC ELECTRIC COMPANY • Northlake,III;no;s I- I ! I I I TCI Library: www.telephonecollectors.info i TCI Library: www.telephonecollectors.info /. ~~ TABLE OF CONTENTS Editor's Preface ......................... v I. THIS IS A ROTARY STEPPING SWITCH 1 II. ROTARY STEPPING SWITCH NOMENCLATURE..... 5 Mechanical Components ......................... 5 Types of "Drive" ............................. .. 10 Direction of Stepping " 12 III. BASIC OPERATING CIRCUITS FOR INDIRECTLY DRIVEN ROTARY STEPPING SWITCHES 15 Pulsed Stepping 16 All rights reserved, including· the right of reproduction Self-Interrupted Stepping 18 in whole or in part, in any form. Considerations of Maximum Circuit-Closure Time " 19 Pulse-Inversion Circuit. ........................ .. 20 Copyright, 1964, AUTOMATIC ELECTRIC COMPANY. IV. "HOMING" OF ROTARY STEPPING SWITCHES 22 Published by AUTOMATIC ELECTRIC COMPANY, Northlake, Illinois. Direct-Drive 22 Indirect-Drive 23 First Edition, March 30, 1964. Self-Interrupted Stepping and Homing of the Type 45NC. 25 V. BASIC THINGS YOU CAN DO WITH Printed in the United States of America.
    [Show full text]
  • 3. Relays Contents
    3. Relays Contents 1 Relay 1 1.1 Basic design and operation ...................................... 1 1.2 Types ................................................. 2 1.2.1 Latching relay ......................................... 2 1.2.2 Reed relay ........................................... 3 1.2.3 Mercury-wetted relay ..................................... 3 1.2.4 Mercury relay ......................................... 3 1.2.5 Polarized relay ........................................ 4 1.2.6 Machine tool relay ...................................... 4 1.2.7 Coaxial relay ......................................... 4 1.2.8 Time delay .......................................... 4 1.2.9 Contactor ........................................... 4 1.2.10 Solid-state relay ........................................ 4 1.2.11 Solid state contactor relay ................................... 5 1.2.12 Buchholz relay ........................................ 5 1.2.13 Forced-guided contacts relay ................................. 5 1.2.14 Overload protection relay ................................... 6 1.2.15 Vacuum relays ........................................ 6 1.3 Pole and throw ............................................. 6 1.4 Applications .............................................. 7 1.5 Relay application considerations .................................... 8 1.5.1 Derating factors ........................................ 9 1.5.2 Undesired arcing ....................................... 9 1.6 Protective relays ...........................................
    [Show full text]
  • Electrical Devices Used in Launching Systems
    CHAPTER 9 ELECTRICAL DEVICES USED IN LAUNCHING SYSTEMS INTRODUCTION system. Relay and switch arrangements provide switching from one type of control to another. In this chapter we discuss the basic operating Some launching systems are capable of stowing principles of switches and relays. Also, we take up mixed loads. For example, several kinds of Terriers the application of these units in launching system such as BT-3 and HT-3 are stowed in the same control circuits. To maintain electrical and ready service ring. Mixing of missiles implies that electronic circuits efficiently and effectively, you some method is provided to locate and to select a must have this background knowledge. desired missile for loading and firing. Special In most missile launching systems, the devices, which incorporate switches and relays, are equipments are normally located at considerable used to perform the missile stowage locating and distances from each other. For example, the selecting function. The Mk 9 GMLS uses a launcher captain's control panel is more than 50 stepping switch to select a cell from which a feet from the launcher, yet he must be able to missile can be selected. In the Mk 10 GMLS, this control the launcher without leaving his station. action is one of the functions of the load status How is this particular problem solved? Remote recorder, and in the Mk 13 GMLS a ratchet relay is control is the answer. Remote (indicating and utilized. Though the names of these devices differ, control) circuits are made up of switches, relays, they all operate to perform the same general and other devices, which control the output from purpose.
    [Show full text]
  • TOPIC 2:SWITCHING INTRODUCTION 1.Strowger (Step-By-Step) Switching
    TOPIC 2:SWITCHING INTRODUCTION 1.Strowger (step-by-step) switching The Strowger switch, also known as Step-by-Step or SXS, is an early electromechanical telephone switching system invented by Almon Brown Strowger. It is a specialized version of a stepping switch. Step by Step Switching or Strowger switching was the first automatic telephone system introduced by Almon B. Strowger. This system uses selectors for switching. The selectors used in Strowger exchange are mainly of two types: 1. Uniselector 2. Two motion selector. Both the selectors belong to the same types of switches called rotary switches. UNISELECTOR This is called uniselector because the rotary motion of this switch is in one direction, i.e., the wiper assembly moves only in one direction. The uniselector consists of moving contacts called wipers. These are used to make electrical connections with any one of several contacts, called bank contacts, in an arc around it. The arc in most cases consists of ten steps. The wiper assembly is divided into three sets of wipers so that the switch has to turn through only one third of a full circle when operated. These wipers are operated by an electromagnet, called driving magnet, with the help of a ratchet and pawl mechanism. When current flows through the windings of the driving magnet, it is energised and attracts the armature; the pawl slips over one tooth of the ratchet wheel. The ratchet is prevented from movement in the reverse direction by a detent. When the current stops through the windings of the driving magnet, it is de-energised, and the armature comes back to its rest position.
    [Show full text]
  • Wiring Manual Automation and Power Distribution
    Wiring Manual Automation and Power Distribution Moeller addresses worldwide: www.moeller.net/address Wiring Manual E-mail: [email protected] Internet: www.moeller.net L1 L2 L3 21 1 3 5 13 -Q1 L 14 22 N Issued by Moeller GmbH B -F1 I > I > I > Hein-Moeller-Str. 7-11 2 4 6 D-53115 Bonn ~ +12 V 0 V © 2006 by Moeller GmbH, Germany 1 3 5 1 3 5 1 3 5 L01h -Q11 -Q15 -Q13 F1 Subject to alteration 2 4 6 2 4 6 2 64 N01 h FB0200-004GB-INT MDS/Doku/ 02/05 97 95 A -F2 Printed in the Federal Republic of 2 4 6 98 96 Germany (04/06) PE Article No.: 106254 U1 V2 V1 M W2 W1 3 U2 L N NI1 I7 I8 -M1 For Immediate Delivery call KMParts.com at (866) 595-9616 All brand and product names are trade marks or registered trademarks of the owner concerned 1st edition 2000, 12/99 2nd updated edition 2006, publication date 02/05 © Moeller GmbH, Bonn Editor: Heidrun Riege Translators: Uli Wright, Nigel Green, Dominik Kreuzer, David Long, Terence Osborn All the circuits are designed according to our best expertise and have been carefully tested. They serve as practical examples. Moeller GmbH refuses to accept liability for any errors. All rights reserved, including those of the translation. No part of this manual may be reproduced in any form (printed, photocopy, microfilm or any other process) or processed, duplicated or distributed by means of electronic systems without the written permission of Moeller GmbH, Bonn, Germany.
    [Show full text]
  • Aviation Ordnanceman
    NONRESIDENT TRAINING COURSE July 2001 Aviation Ordnanceman NAVEDTRA 14313 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Although the words “he,” “him,” and “his” are used sparingly in this course to enhance communication, they are not intended to be gender driven or to affront or discriminate against anyone. DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. PREFACE By enrolling in this self-study course, you have demonstrated a desire to improve yourself and the Navy. Remember, however, this self-study course is only one part of the total Navy training program. Practical experience, schools, selected reading, and your desire to succeed are also necessary to successfully round out a fully meaningful training program. COURSE OVERVIEW: When you complete this course you will be familiar with bombs, fuzes, aircraft rockets and rocket launchers, air-launched guided missiles and guided missile launchers, pyrotechnics, air-laid mines and torpedoes, M61A1 gun installations, ammunition loading, and targets and associated equipment. You will also become familiar with ammunition handling equipment, suspension, arming, and releasing equipment, and ammunition handling and storage ashore and afloat. Additionally, you will learn about aircraft weapons systems, weapons assembly, and aircraft loading and unloading procedures. You will also learn about aircraft weapons testing equipment and ammunition administration ashore and afloat. THE COURSE: This self-study course is organized into subject matter areas, each containing learning objectives to help you determine what you should learn along with text and illustrations to help you understand the information. The subject matter reflects day-to-day requirements and experiences of personnel in the rating or skill area.
    [Show full text]
  • Escuela Politecnica Del Ejercito
    ESCUELA POLITECNICA DEL EJERCITO DEPARTAMENTO DE ELECTRICA Y ELECTRONICA CARRERA DE INGENIERIA EN ELECTRONICA Y TELECOMUNICACIONES PROYECTO DE GRADO PARA LA OBTENCION DEL TITULO DE INGENIERIA DIMENSIONAMIENTO Y DISEÑO DEL CONTACT CENTER INSTITUCIONAL DEL SERVICIO DE RENTAS INTERNAS JOSE EDUARDO PAREDES SANDOVAL Sangolquí – Ecuador 2010 CERTIFICACION En calidad de Director y Codirector del Proyecto de grado titulado DIMENSIONAMIENTO Y DISEÑO DEL CONTACT CENTER INSTITUCIONAL DEL SERVICIO DE RENTAS INTERNAS, certificamos que fue realizado en su totalidad por José Eduardo Paredes Sandoval, con CI 1801789197, bajo nuestra dirección. Ing. Carlos Romero G. Ing. Fabián Sáez E. DIRECTOR CODIRECTOR RESUMEN En el presente trabajo, se realiza una reseña histórica de la evolución de la telefonía, se hace un estudio del SRI, institución que requiere esta herramienta para comunicarse con sus usuarios, se analizan los datos estadísticos disponibles de la penetración de las tecnologías de la información en el Ecuador, así como los datos sobre el giro del negocio del SRI, se determina cual será el tráfico estimado, tanto entrante como saliente, se define que información se ofrecerá a los usuarios y cual va a ser la forma de entregarla. Se diseñan los diagramas de flujo de las opciones del menú del IVR. En base a esas necesidades se diseña la arquitectura del sistema. Luego se analizan los modelos matemáticos que se usarán para calcular los recursos necesarios para atender las necesidades planteadas, cumpliendo niveles de servicio adecuados. Para esto, en base a las fórmulas planteadas, se desarrolla una hoja electrónica que facilita la ejecución de los cálculos. Se resumen los recursos requeridos y se plantea una forma de implementación, cuantificación del personal y organización de turnos.
    [Show full text]
  • Switch Contents
    Switch Contents 1 Switch 1 1.1 Description .............................................. 1 1.2 Contacts ................................................ 2 1.2.1 Contact terminology ..................................... 2 1.2.2 Contact bounce ........................................ 3 1.2.3 Arcs and quenching ...................................... 3 1.2.4 Power switching ....................................... 3 1.2.5 Inductive loads ........................................ 4 1.2.6 Incandescent loads ...................................... 4 1.2.7 Wetting current ........................................ 4 1.3 Actuator ................................................ 4 1.3.1 Biased switches ........................................ 4 1.3.2 Rotary switch ......................................... 4 1.3.3 Toggle switch ......................................... 5 1.4 Special types .............................................. 6 1.4.1 Mercury tilt switch ...................................... 6 1.4.2 Knife switch .......................................... 6 1.4.3 Footswitch .......................................... 6 1.4.4 Reversing switch ....................................... 7 1.5 Light switches ............................................. 7 1.6 Electronic switches .......................................... 7 1.7 Other switches ............................................. 7 1.8 See also ................................................ 8 1.9 References .............................................. 8 1.10 External links ............................................
    [Show full text]
  • Field Test Procedure for Protective Relays, May 2011
    Facilities Instructions, Standards, and Techniques Volume 3-8 Operation, Maintenance, and Field Test Procedures for Protective Relays and Associated Circuits Previously Titled: Field Testing Procedures for Protective Relays U.S. Department of the Interior Bureau of Reclamation Denver, Colorado May 2011 Form Approved REPORT DOCUMENTATION PAGE OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing this collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202- 4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY)T 2. REPORT TYPE 3. DATES COVERED (From - To)T May 2011 Final 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER FIST 3-8, Operation, Maintenance, and Field Test Procedures for Protective Relays and Associated Circuits 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER Paul Price, Nate Myers, Jim DeHaan Bureau of Reclamation 5e. TASK NUMBER Hydropower Technical Services Group Denver, Colorado 5f. WORK UNIT NUMBER 7.
    [Show full text]