Moeller Wiring Manual 02/05 Specifications, Formulae, Tables
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Schindler Schindler / Westinghouse Quick Locator Guide
www.SEESinc.com SCHINDLER/WESTINGHOUSE SCHINDLER / WESTINGHOUSE QUICK LOCATOR GUIDE Belts . 607 Brushes . 608-611 Brush Holders . 612-613 Capacitators. 630 Car Signal Components . 600-606 Gongs . 606 Emergency Stop Switch . 600, 602-603 Key Switches and Keys . 600, 604, 606 Lantern Lens. 605 Position Indicators . 604 Pushbutton Assemblies . 600-603, 606 Switches, Rocker and Reed. 606 Coils . 614-616 Door Parts And Equipment . 617-629 Cables and Pulleys . 628-629 Door Keys and Escutcheons . 625 Door Roller Assemblies. 628 Gibs, Guides . 625, 656 Hatch Equipment . 619 Interlock Components . 617, 620-622 Door Motors . 619, 629 Operators . 626-627 Safety Edge Parts . 623 Spirator, Reel Closer . 624 Track Liner . 629 Electronics - Tubes, Breakers, Fans . 631 Machine Parts . 632-636 Gaskets, Seals and Bearings. 632-636 Motors . 619, 629, 647 Printed Circuit Boards . 637-641 Rectifiers . 630 Relays . 643-644 Relay Components. 644-648 Resistors. 642 Selector Components . 649-650 Switches . 648-650 Transformers . 651 Wheels And Rollers . 652-655 Hanger Assemblies. 653-654 Hanger Rollers . 653-654 Roller Guide Assemblies . 655 Roller Guide Wheels . 654-655 954.971.1115 / fax 954.917.7337 800.526.0026 599 www.SEESinc.com Car Signal Components SB-2 SB-3 SB-4 SB-1 SCH-KCY-001 SCH-KCY-002 SB-5 SB-6 SB-6-VAN SB-1BR-7 SK-1 SKS-2A SKS-1 SK-3 SK-4 SK-5 SKS-2 SK-2 S.E.E.S. # O.E.M. # Description SB-1 8544C17G04 Button Housing, with lens SB-1BR- 6954C71H01 Braille Plate, braille for SB-1 housing, Stainless Steel, 1” x 1.187” SCHINDLER/WESTINGHOUSE (specify marking) SB-1BR-ARROW_DOWN Braille, Down Arrow For SB-1 SB-1BR-ARROW_UP Braille, Up Arrow For SB-1 SB-2 8540C58H02 Button Retainer Bracket SB-2A 70010CSC3R Screw, 6-32 x 1/2" Hex Washer Head, Slotted SKS-3 SB-3 7283C730G02 Printed Circuit Board Assembly for pushbutton, two micro switch type SB-4 7283C730G01, Printed Circuit Board Assembly for pushbutton, one 998C278H11 micro switch type SCH-KCY-001 D3158-057A/AS100 Key Switch, PHI, 3 position with AS100 key SCH-KCY-002 D3158-057B/AS100 Key Switch, PHII, 3 pos, AS100 key, per yr. -
Switches and Relays for the Power Industry
Switches and Relays For the Power Industry E L E C T R O NEVER S W I T A DOUBT C H U T I L I T Y ELECTROSWITCH Corporation 180 King Avenue P Weymouth, MA 02188 R TEL: (781) 335-5200 O FAX: (781) 335-4253 www.electroswitch.com D U C T S 5M 113 Printed in USA U.2.D THE ELECTRO SWITCH CORPORATion Family… PROVIDING INTELLIGENT SOLUTIONS FOR SWITCHING AND CONTROL Complete line of electrically and manually activated Rotary Switches and Relays POWER SWITCHES & RELAYS for electric utility, defense, and industrial monitoring and control applications The Best Rotary Switches, Relays, and Electrical Systems Products... Backed by the industry’s most www.electroswitch.com knowledgeable and responsive Rotary Switches; Miniature Toggle, Paddle, Rocker, Power Toggle, and Push- ELECTRONIC PRODUCTS Button Switches; Hall Effect, and Mechanical Encoders; Illuminated Switch engineering and customer Products; and Power Transformers service professionals... Any way you want them... Delivered when you need them. www.electro-nc.com DIGITRAN Digital and Rotary Switch Products designed for aviation, defense, and industrial DIGITAL & ROTARY SWITCHES switch applications ELECTROSWITCH www.digitran-switches.com ARGA CONTROLS Electric utility, industrial and military-grade Power Meters, Battery Monitors, MEASUREMENT & CONTROL INSTRUMENTATION and Transducers for precision measurement applications NEVER www.argacontrols.com Sunrise Technologies Wireless Communication Systems for Smart Grid applications and a complete A DOUBT OUTDOOR LIGHTING CONTROLS & MONITORING line -
GE Kv Vector Electricity Meter
GEH-5081B GE kV™ Vector Electricity Meter Product Description Option Board Installation Procedures, Operating Instructions, Maintenance Instructions and Site Analysis Guides Price: $ 30.00 Notice The information contained in this document is subject to change without notice. GE makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. GE shall not be liable for errors contained herein or incidental consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied or otherwise reproduced without consent of GE. Copyright (c) 1997 by GE Published in a limited copyright sense, and all rights, including trade secrets, are reserved. Document Edition - First 4/96 - Version A 5/97 - Version B 11/97 kV™, Lexan™, MeterMate™, OPTOCOM™, Power Guard™, Site Genie™, Fitzall, and SMARTCOUPLER™ are trademarks of GE. FCC COMPLIANCE STATEMENT This product generates and uses radio frequency energy. It has been tested and verified that it complies with the limits for the Code of Federal Regualtions (CFR) 47, Part 15 Radio Frequency Devices, Subparts A General and B Unintentional Radiators issued by the Federal Communications Commission for Class “B” digital devices. If, however, the product causes radio or television interference, notify: Manager - Technology General -
Nortec RS Steam Humidifier Operation Manual
2582418-A EN | 06 AUG 2015 EN | 06 2582418-A OPERATION MANUAL Steam humidifier Nortec RS Humidification and Evaporative Cooling Thank you for choosing Nortec Installation date (MM/DD/YYYY): Commissioning date (MM/DD/YYYY): Site: Model: Serial number: Manufacturer Nortec Humidity Ltd. 2740 Fenton Road, Ottawa, Ontario K1T3T7 TEL: 1.866.NORTEC1, FAX: 613.822.7964 EMAIL: [email protected], WEBSITE: www.humidity.com Proprietary Notice This document and the information disclosed herein are proprietary data of Nortec Humidity Ltd. Neither this do- cument, nor the information contained herein shall be reproduced, used, or disclosed to others without the written authorization of Nortec Humidity Ltd., except to the extent required for installation or maintenance of recipient's equipment. Liability Notice Nortec Humidity Ltd. does not accept any liability due to incorrect installation or operation of the equipment or due to the use of parts/components/equipment that are not authorized by Nortec Humidity Ltd. Copyright Notice Copyright 2015, Nortec Humidity Ltd. All rights reserved. Technical modifications reserved Contents 1 Introduction 5 1.1 Before You Begin 5 1.2 Notes on the Operation Manual 5 2 For Your Safety 7 3 Product Overview 9 3.1 Construction Nortec RS steam humidifier 9 3.2 Functional Description 10 3.3 System Overview Nortec RS 11 3.4 System Overview Nortec RS for Direct Room Humidification 12 4 Operation 13 4.1 First-time Commissioning 13 4.2 Display and Operating Elements 13 4.3 Commissioning After an Interruption of Operation -
How to Use Rotary Stepping Switches Wisely and Fig
$1.45 ROTARY HOW TO USE STEPPING SWITCHES Photographs on the front and back cover are of AE's Type 45 Rotary Stepping Switch Today's rotary stepping switches are wired for hermetic seaJing. the result of decades of service usage and experience. Here, in one book, are the major "DO's" and "DON'T's" of their successful application. AUTOMATIC ELECTRIC Subsidiary 01 GENERAL GENERAL TELEPHONE & ELECTRONICS ~ C·1057-40M -3· Merit Printed in the U.S.A. TCI Library: www.telephonecollectors.info TCI Library: www.telephonecollectors.info II 1- HOW TO USE ,. ROTARY STEPPING SWITCHES V. E. JAMES, Editor Ii· i !I ! I' \ 1 ! r • AUTOMATIC ELECTRIC COMPANY • Northlake,III;no;s I- I ! I I I TCI Library: www.telephonecollectors.info i TCI Library: www.telephonecollectors.info /. ~~ TABLE OF CONTENTS Editor's Preface ......................... v I. THIS IS A ROTARY STEPPING SWITCH 1 II. ROTARY STEPPING SWITCH NOMENCLATURE..... 5 Mechanical Components ......................... 5 Types of "Drive" ............................. .. 10 Direction of Stepping " 12 III. BASIC OPERATING CIRCUITS FOR INDIRECTLY DRIVEN ROTARY STEPPING SWITCHES 15 Pulsed Stepping 16 All rights reserved, including· the right of reproduction Self-Interrupted Stepping 18 in whole or in part, in any form. Considerations of Maximum Circuit-Closure Time " 19 Pulse-Inversion Circuit. ........................ .. 20 Copyright, 1964, AUTOMATIC ELECTRIC COMPANY. IV. "HOMING" OF ROTARY STEPPING SWITCHES 22 Published by AUTOMATIC ELECTRIC COMPANY, Northlake, Illinois. Direct-Drive 22 Indirect-Drive 23 First Edition, March 30, 1964. Self-Interrupted Stepping and Homing of the Type 45NC. 25 V. BASIC THINGS YOU CAN DO WITH Printed in the United States of America. -
RELAY and CONTROL REQUIREMENTS for PARALLEL OPERATION of DISTRIBUTED GENERATION (12Kv and Below)
EU00536095 RELAY AND CONTROL REQUIREMENTS FOR Revision:0 PARALLEL OPERATION OF GENERATION Effective Date: 12/11/2017 Page 1 of 67 PPL ELECTRIC UTILITIES CORPORATION RELAY AND CONTROL REQUIREMENTS FOR PARALLEL OPERATION OF DISTRIBUTED GENERATION (12kV and below) REV. 0, 12/11/2017 By: Deepak Sharma Reviewer: signed Thien Hoang – Supervising Engineer Distribution Design and Standards Approver: signed Michael J. Wolf – Supervising Engineer Distribution Substation Design SHEET 1 of 67 EU00536095 RELAY AND CONTROL REQUIREMENTS FOR Revision:0 PARALLEL OPERATION OF GENERATION Effective Date: 12/11/2017 Page 2 of 67 TABLE OF CONTENTS TABLE OF CONTENTS ........................................................................................................................... 2 1 FOREWORD ........................................................................................................................................ 5 2 SCOPE ................................................................................................................................................... 6 3 OVERVIEW .......................................................................................................................................... 7 3.1 INITIATING A REQUEST TO INSTALL OR CHANGE OPERATION OF GENERATION EQUIPMENT ............................................................................................................................................................. 8 3.2 POINT OF CONTACT (POC) and INTERTIE PROTECTIVE RELAYING (IPR) ................................... -
3. Relays Contents
3. Relays Contents 1 Relay 1 1.1 Basic design and operation ...................................... 1 1.2 Types ................................................. 2 1.2.1 Latching relay ......................................... 2 1.2.2 Reed relay ........................................... 3 1.2.3 Mercury-wetted relay ..................................... 3 1.2.4 Mercury relay ......................................... 3 1.2.5 Polarized relay ........................................ 4 1.2.6 Machine tool relay ...................................... 4 1.2.7 Coaxial relay ......................................... 4 1.2.8 Time delay .......................................... 4 1.2.9 Contactor ........................................... 4 1.2.10 Solid-state relay ........................................ 4 1.2.11 Solid state contactor relay ................................... 5 1.2.12 Buchholz relay ........................................ 5 1.2.13 Forced-guided contacts relay ................................. 5 1.2.14 Overload protection relay ................................... 6 1.2.15 Vacuum relays ........................................ 6 1.3 Pole and throw ............................................. 6 1.4 Applications .............................................. 7 1.5 Relay application considerations .................................... 8 1.5.1 Derating factors ........................................ 9 1.5.2 Undesired arcing ....................................... 9 1.6 Protective relays ........................................... -
Panasonic Switches
GENERAL CATALOG SWITCHES Panasonic Switches Development cycles in modern industry are becoming ever shorter and more complex, and they require a high degree of engineering. Components integrated into machines must therefore not only meet the current qualitative and technical standards but must also fulfill functional and application demands. Individual products can often only be integrated after they have been customized. Panasonic Electric Works has always stood for product innovation – also when it comes to mechanical switches. Our immense portfolio includes switches in all common sizes and with various IP degrees of protection, and are guaranteed to cover all standard requirements. Our switches are characterized by a large switching capacity range, long lifetime and exceptional reliability. A wide selection of supplemental actuators coupled with various terminal styles, e.g. solder, quick connect, PC board terminal and cable connections, maximize flexibility and ease application design. In addition, we concentrate on the development and implementation of customer-specific solutions: Does the cable have to be a little bit longer? Or is a pluggable solution necessary? With the engineering know-how at our European manufacturing sites, we guarantee flexible, on-time delivery and provide immediate, on-site technical support. Product lineup 36 3 1 8 ASQ ABJ ABS ABV 8 2 27. 8 AV4 AH1 AEQ AV3/AVM3/AVT3/AVL3 AV6 AM5 AM1 AV1 AGX AJ7/8 T Series Tailoring equipment 2 Contents Selector Chart........................................................... 4 AM5 (QV) switches (contact gap more than 1mm).. 80 Micro switches IP67.................................................... 4 AEQ (EQ) switches.................................................. 81 Micro switches IP40.................................................... 6 AV (FS•FS-T) switches............................................ 86 Basic switches...................................................... -
Electrical Devices Used in Launching Systems
CHAPTER 9 ELECTRICAL DEVICES USED IN LAUNCHING SYSTEMS INTRODUCTION system. Relay and switch arrangements provide switching from one type of control to another. In this chapter we discuss the basic operating Some launching systems are capable of stowing principles of switches and relays. Also, we take up mixed loads. For example, several kinds of Terriers the application of these units in launching system such as BT-3 and HT-3 are stowed in the same control circuits. To maintain electrical and ready service ring. Mixing of missiles implies that electronic circuits efficiently and effectively, you some method is provided to locate and to select a must have this background knowledge. desired missile for loading and firing. Special In most missile launching systems, the devices, which incorporate switches and relays, are equipments are normally located at considerable used to perform the missile stowage locating and distances from each other. For example, the selecting function. The Mk 9 GMLS uses a launcher captain's control panel is more than 50 stepping switch to select a cell from which a feet from the launcher, yet he must be able to missile can be selected. In the Mk 10 GMLS, this control the launcher without leaving his station. action is one of the functions of the load status How is this particular problem solved? Remote recorder, and in the Mk 13 GMLS a ratchet relay is control is the answer. Remote (indicating and utilized. Though the names of these devices differ, control) circuits are made up of switches, relays, they all operate to perform the same general and other devices, which control the output from purpose. -
Technical Information ■ Relay Classification
Introduction Introduction Technical Information ■ Relay Classification Model Mounting Enclosure Ratings Features G4W Discrete Unsealed Designed for manual soldering. G2R Flux protection Designed inhibits flux intrusion into the casing from the ter- minals during soldering. G6A Sealed Sealed resin casings and covers, limiting damage from cor- rosive atmospheres. G6S Surface mounting Surface mounting relays permit automatic reflow soldering. ■ Construction Sealing Sealed Relays Unsealed Relays Fully sealing prevents not only flux, but also cleaning solvent from Relays of this type are intended for manual soldering. No mea- penetrating into the relay housing. Therefore, this type of relay sures are taken against penetration of flux and cleaning solvent can be immersion-cleaned. Relays are each tested before being into the relay. This type of relay cannot be immersion-cleaned. shipped. The relay is immersed in fluorocarbon solution for 1 +5°C Flux-protection Relays minute, at a temperature of 70°C /−0°C, to see if gases escape from the relay. The following figure illustrates the test conditions. Special design construction prevents flux from penetrating into the relay housing, for example, due to capillary action up the ter- minals when the relay is soldered onto a PCB. This type of relay also cannot be immersion-cleaned. 50 mm Ex.) 70 °C Relay Fluorocarbon solution Classification Unsealed Flux protection Construction Contacts located at Press-fit terminals Inserted terminals upper part of relay case Terminals separated from PCB Terminals Resin seal separated Terminals from PCB separated 0.3 mm from PCB min. base thickness Features Terminals are separated Contacts are positioned Terminals are pressed Terminals are inserted from PCB surface when away from base. -
2003 Cat.Pdf
What’s New - New Products - What’s New High Voltage Reed Switches Tilt Switch See page 37 This series of switches is designed for Non-Mercury relays which are used in high reliability areas of the elec- trotechnical and electronic industry including electronic medical equip- Changeover ment; cable tester arrays and cable test equipment; copy machines; laser optical systems and infrared equipment; test equipment S1234 They provide high voltage stand-off and switching capability. The tung- See page 78 sten plated contacts give both a low stable CR and a long and reliable life. Surface Mount Mercury free changeover tilt switch with hermetically sealed gold contacts, Switch and and a case size of just 7.6mm. It’s rugged construction makes this Sensors switch suitable for many uses in secu- The Comus Group can now supply rity products, alarm and general move- surface mount termination for a wide ment sensing. rated at 60V, 0.2A and range of products. The gold plated clips See page 70 3VA Max. give good solderability and are designed to provide stability during assembly. Magtrix Connectors are versatile miniature Magtrix Neodymium-iron-boron nickel plated 6.0 Dia x Connector 5mm long magnets connected to a 40 x 0.65mm Dia. copper-tin plated flexible lead, with an operating MC/53GNS temperature of 120°C and a maximum power rating See page of 8 Amps. Primarily designed for use as battery connectors, 68 they are also ideal for proximity sensor and reed switch triggering, connecting PCBs, test equipment connections and prototypes where connections need to be made quickly. -
• Relay Contact Protection • Noise Reduction on Controllers/Drivers • Dv
Type Q/QRL Quencharc®Capacitor RC Snubber Network Arc Suppressor • Relay contact protection • Noise reduction on controllers/drivers Snubber Network • dv/dt suppression on thyristor and triacs • EMI/RFI reduction • No lag time in suppression • Available voltages: 125 VAC - 660 VAC • Type QRL – UL/CSA version L Max. TMax. ® Quencharc¤ ITW PAKTRON QUENCHARC¤ Arc Suppressor Snubber Network ITW PAKTRON H Max. Q/QRL QUENCHARC¤ UL/CSA version .25" Max. .850" Min. ARCING, SPARKING, and TRANSIENTS often cause premature failures in relays, switches, thyristors, triacs, contactors, and related products. Paktron QUENCHARCS¤ extend operating life when properly selected and applied. D Typ. VoltagE WavefoRM CURRENT WavefoRM Electrical Schematic Non-polarized UNSUPPRESSED SUPPRESSED UNSUPPRESSED SUPPRESSED 100V/div .1ms/div 100V/div .5ms/div 100V/div .1ms/div 100V/div .1ms/div PF Value Voltage Type Ohms Watt L T H D Part Code µF VDC/VAC ±10% MAX MAX MAX Typical Number 104 .1 600 / 250 QC 22 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC22 104 .1 600 / 250 QC 47 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC47 104 .1 600 / 250 QC 100 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC100 104 .1 600 / 250 QC 150 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC150 104 .1 600 / 250 QC 220 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC220 104 .1 600 / 250 QC 330 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC330 104 .1 1200/480 QH 39 2.0 1.60(40.6) .64(16.3) 1.04(26.4) 1.29(32.7) 104M48QH39 104 .1 1600/660 QV 39 2.0