/ Lighting Controls Product Catalog It’s not just smarter. It’s easier.

Acuity Controls is advanced lighting controls technology, service and support from a single expert source. We offer one of the industry’s most extensive product portfolios for indoor and outdoor applications, single rooms to campuses to municipalities. Our product solutions include occupancy and photosensors, panels, , fixture-level and wireless controls.

Printed on Recycled Paper Contents

5 ABOUT SENSOR 38 DAYLIGHTING CONTROL SENSORS 6 Benefits 38 Ceiling Mount 7 Sensor Technology 42 Recessed Mount 8 Sensorpedia: Occupancy Sensor Reference Guide 48 Fixture Mount 54 Fixture Mount Interchangeable Lens 21 PRODUCT SELECTION GUIDE 22 Wall Switch Controls 60 POWER PACKS 32 Wireless Products 34 Ceiling Mount Sensors 75 SPECIALTY PRODUCTS 40 Recessed Mount Sensors 76 Data Logging Monitoring System 44 Fixture Mount Sensors 78 Wire Guards 50 Fixture Mount Interchangeable Lens Sensors 79 Masking Labels 56 Wide View & Hallway Sensors 79 Ballast Discriminator 58 Outdoor Sensors 60 Power Packs 81 WIRING DIAGRAMS 62 Micro Enclosure 64 Snap-Fit 94 INDEX 69 Embedded

The Sensor Switch product line Performance from Acuity Controls provides an innovative, high quality and You Can Count On! cost-effective controls solution for every application. Our occupancy Our Passive Dual Technology (PIR/Microphonics™) sensors and photocell products are • looks and listens for occupants ensuring reliable detection easy to install and easy to use. • Reversible line and load wires make Sensor Switch products easy to install

• Reliable-circuit protection tested for over 400,000 switching cycles

• Continuous coverage patterns for a breadth of applications meeting your every need

• 5-year limited product warranty

• Sensor Switch products aid in ensuring buildings meet applicable energy codes (Title 24, ASHRAE and IECC)

www.acuitycontrols.com / 5 BENEFITS

Energy Savings

The Sensor Switch offering of occupancy and daylight sensors are designed to optimize energy savings and enable sustainability. Our broad product offering provides solutions for applications requiring energy code compliance. Using innovative detection technologies that maximize energy savings we save you more!

Reliable Performance

Sensor Switch is a leader in lighting control innovation, continuously developing technologies to enhance performance of our occupancy sensors and photocells providing trusted quality and reliability. We offer a broad selection of occupancy and daylight sensors to meet every application.

Ease of Installation

Sensor Switch products are easy to install due to our patented features; reversible line and load wires (Miswire Protection), simple push button programming and our Convertible Neutral for Wall Switches! These powerful features save install time and eliminate extra costs on the job site!

6 / www.acuitycontrols.com INNOVATING SENSOR TECHNOLOGY

Sensor Switch is dedicated to providing innovative sensor technologies for applications requiring compliance to energy codes.

MICROPHONICS™

Microphonics technology utilizes a microphone inside the sensor to “hear” sounds indicating occupancy. This technology is perfect for rooms with obstructions where traditional PIR sensors cannot “see” the room occupant. Microphonics is superior as it provides better detection performance, requires less power, and does not transmit sound waves into the space, eliminating potential for interference.

MISWIRE PROTECTION

Sensor Switch developed reversible line and load connections resulting in products that are impossible to wire backwards. This patented feature eliminates potential jobsite delays due to miswiring.

CONVERTIBLE NEUTRAL

This is patent-pending technology allows a Sensor Switch Wall Switch occupancy sensor (WSX & WSD) to convert from a no neutral connection to a neutral and ground connection in seconds! If your application requires the use of a neutral connection, simply remove the ground link and wire per code, making installation quick and easy. One sensor does it all!

SELF-CALIBRATING DAYLIGHT CONTROLS

All photocontrols have an automatic set-point calibration mode regardless of time-of-day or daylight conditions improving installation time!

www.acuitycontrols.com / 7 The Encyclopedia of Sensor Switch SENSORPEDIA

This guide is intended to assist with choosing the appropriate Sensor Switch occupancy sensor for your space and application.

Each character or group of characters in a Sensor Switch model number indicates a specific feature or option for that particular sensor. The sections of this guide describe the choices available for each of the feature categories.

By dividing up any Sensor Switch occupancy sensor model number into the parts described in this guide, the sensor’s full functionality can be determined. This guide will also better enable you to build your own model numbers by choosing from each category the features and options your project requires.

8 / www.acuitycontrols.com PRODUCT NAMING CONVENTION GUIDE

The product model numbers (i.e., CM 9) provide details on the particular product; such as, mounting type, power information, lens type etc. By understanding the product naming convention this will help you select the product that is correct for your application.

The example below shows the categories that make up the model number CMR PDT 10 P.

Enclosure Power Detection Lens Options

CM R PDT 10 P

10 ENCLOSURES

14 POWER TYPE / WIRELESS

DETECTION TECHNOLOGY 15

LENS TYPE 16

OPTIONS 19

www.acuitycontrols.com / 9 10 SENSORPEDIA ENCLOSURES /www.acuitycontrols.com SENSORPEDIA SPODM WSX letters in their model number. model their in letters few first the by indicated is sensors most for style enclosure The to install. easy being still while attractive and functional both are that styles enclosure different of a variety in come sensors occupancy Switch Sensor ENCLOSURES SPODMR WR SPODMR Wireless Wall Switch WSX, WSX NL WSX WSX, Switch Wall Color: Mounting: Physical Specs(notincludingmountingstrap): Color: Mounting: Physical Specs(notincludingmountingstrap): Weight: D: W: H: Weight: D: W: H: Ivory, Light Almond White, Gray, Black Single GangSwitchBox 5 oz 1.63” (4.14cm) 1.68” (4.27cm) 2.74” (6.96cm) Ivory,Light Almond White, Gray, Black, Red, Single GangSwitchBox 5 oz 1.63” (4.14cm) 1.68” (4.27cm) 2.74” (6.96cm)

COLOR CHOICES BLACK * LWSH WSD LWS SSD LIGHT ALMOND WSD, SSD Wall Switch LWS, LWSH LWS, Wall Area Large Switch Color: Mounting: Physical Specs(notincludingmountingstrap): Color: Mounting: Physical Specs(notincludingmountingstrap): 1 Weight: D: W: H: Weight: D: W: H: Available in White andIvoryonly. * WHITE White, Ivory Single GangSwitchBox 7 oz 1.70” (4.32cm) 3.10” (7.87cm) 4.96” (12.60cm) Ivory,Light Almond White, Gray, Black, Red Single GangSwitchBox 5 oz 1.63” (4.14cm) 1.68” (4.27cm) 2.74” (6.96cm) 1 IVORY * *Not availableforallenclosures GRAY * RED * ENCLOSURES SENSORPEDIA www.acuitycontrols.com / 11 www.acuitycontrols.com ( 11.56 cm ) ( 3.94 cm ) 3.94 ( 3.00” ( 7.62 cm ) 3.60” ( 9.14 cm ) 1.75” ( 4.45 cm ) 4 oz or to to Corner Directly BR Bracket WV using Ceiling White 4.55” 1.55” 6 oz Tile Ceiling Surface Voltage) (Low 3.5" Octagon Box Single Gang Handy Box White H: W: D: Weight: Diameter: Depth: Weight: Weight: Physical Specs: Mounting: Color: Physical Specs:

Mounting: Color: Wall / Corner Mount / Corner Wall WV, HW Ceiling Mount CM CM WV HW ( 11.56 cm ) ( 6.07 cm ) 6.07 ( 3 4 x 4 square junction box junction box 4 x 4 square with or without two-gang to ceiling mudring; directly 2.65” (6.7 cm) tile through opening square 4.60” (square) ( 11.68 cm ) 4.60” (square) 6 oz  4.50” 2.39” 6 oz Surface Ceiling 3.5" Octagon Box Single Gang Handy Box White 4.96” ( 12.60 cm ) 3.10” ( 7.87 cm ) 1.70” ( 4.32 cm ) 7 oz Single Gang Handy Box Ivory White, , HWR 2 Width: Weight: Diameter: Depth: Weight: Weight: H: W: D: Weight: HWR is the Line Voltage Enclosure of Enclosure the HW Voltage HWR is the Line WVR is the Line Voltage Enclosure of Enclosure WV the Voltage the Line WVR is Physical Specs: Mounting: White Color: Physical Specs:

Mounting: Color: 3 2 Physical Specs: Mounting: Color: Wall / Corner Mount Mount / Corner Wall WVR Recessed Ceiling Mount Mount Recessed Ceiling RM Wireless Ceiling Mount CM XX WR CM RM WVR HWR 12 SENSORPEDIA ENCLOSURES /www.acuitycontrols.com LSXR HMB CMB SBO SBO (Outdoor /Wet Location) Enclosure Single Lens Mount Fixture/Pole CMB, HMB CMB, (Indoor) Enclosure Single Lens Mount Fixture LSXR Enclosures Lens Interchangeable Mount Fixture Color: Mounting: Physical Specs: Color: Mounting: Physical Specs: Color: Mounting: Physical Specs: Weight: D: W: H: Weight: D: W: H: Weight: D: W: H:

White, Black, DarkBronze 1/2” Knockout (7/8”hole) 9 oz 4.00” (10.16cm) 4.40” (11.18cm) 4.88” (12.40cm) 3.35” (8.51cm)or White Box or Junction 1/2” Knockout inFixture 6 oz 1.50” (3.81cm) 3.63” (9.22cm) 3.63” (9.22cm) White 1/2” Knockout (7/8”hole) 6 oz 4.00” (10.20cm) 2.50” (6.40cm) 3.75” (9.50cm)

FB3 FB3 (Indoor) Bracket MountingFixture Physical Specs: Color: White Mounting: H: Weight: D: W: or Junction Box or Junction 1/2” Knockout inFixture 2.52 ozeach (excluding nuts) 1.35” (3.43cm) 2.00” (5.08cm) 5.00” (12.70cm) ENCLOSURES SENSORPEDIA www.acuitycontrols.com / 13 www.acuitycontrols.com

2.25” ( 5.71 cm ) 1.38” ( 3.51 cm ) 0.82” ( 2.08 cm ) 4 oz Snaps into 2-3/16” H x 1” D W x 1-5/16” Black White, 1.34” ( 3.40 cm ) 2.60” ( 6.65 cm ) 1.18” ( 2.99 cm ) 3 oz Hole Size Required 1.125” Material Thickness 0.25” max Black White, 3.35” ( 8.51 cm ) 4.40” ( 11.18 cm ) 4.00” ( 10.16 cm ) 9 oz (7/8” hole) 1/2” Knockout Black White,

H: W: D: Weight: H: W: D: Weight: H: W: D: Weight: Physical Specs: Mounting: Color: cavity in fixture Physical Specs: Mounting: Color: Physical Specs: Mounting: Color: Snap-Fit Location) / Wet (Outdoor SFORSFOD, Embedded Enclosure Micro Location) / Wet (Outdoor MSOD Embedded Small Box Box Small Embedded (Outdoor) SBG SBG SFOR SFOD MSOD 2.25” ( 5.72 cm ) 1.38” ( 3.51 cm ) 0.82” ( 2.08 cm ) 4 oz Snaps into 2-3/16” H x 1” D W x 1-5/16” White 1.34” ( 3.40 cm ) 2.60” ( 6.65 cm ) 1.18” ( 2.99 cm ) 3 oz Hole Size Required 1.125” Material Thickness 0.25” max White 3.40” ( 8.64 cm ) 3.40” ( 8.64 cm ) 1.40” ( 3.56 cm ) 6 oz Opening 2.65” Square in Fixture (minimum depth 1.50”) Black White, H: W: D: Weight: H: W: D: Weight: H: W: D: Weight: Physical Specs: Mounting: Color: cavity in fixture Physical Specs: Mounting: Color: Physical Specs: Mounting: Color: Embedded Embedded Enclosure Micro (Indoor) MSD, ES Snap-Fit (Indoor) SFD SF, Embedded Small Box Box Small Embedded (Indoor) SB SF ES SB SFD MSD 14 SENSORPEDIA POWER TYPE /www.acuitycontrols.com SENSORPEDIA WR LV R need to be added to the model number. number. model to the added to be need characters special no therefore, acircuit; to switch pack apower require and voltage low by powered are sensors default, By capabilities. switching its as well as powered, is sensor a how specifies category This POWER TYPE • • • • Battery / Wireless • • • • VoltageLow • • • • • • Voltage Line Wireless communicates to wireless wall switch (e.g., WR) SPODMR switch wall to wireless communicates Wireless Battery (1.5V) Lithium AA settings) sensor (at default life 10 battery year walls the through wire to difficult are that applications renovation (e.g., for Ideal 9WR); CM battery alithium by powered is sensor Wireless (e.g., wiring 62P) CM voltage low convenient utilizes and box ajunction without mounting sensor Allows space to cover together used to be sensors multiple Enables switched to be circuits Amp 20 complete to enable pack apower with Used source voltage low other or pack power via Powered (e.g., 6480) CMR number model to the 480 or 208 adding by VAC) indicated are 480 or (e.g., 240, 208, phases two switching simultaneously of capable Sensors (e.g., 62P) CMR number model 2Pto the adding by indicated are independently poles two switching of capable Sensors to wire backwards Impossible patented) Switch (Sensor wires &load line Interchangeable ceilings inaccessible or concrete with applications retrofit for Ideal relays switching voltage line contain Sensors with the enclosure designation (e.g.,). CMR designation enclosure the with “ letter the have numbers model voltage Line pack. apower without voltage line switch can and by powered are sensors voltage line contrast, In R ” inserted ” inserted DETECTION TECHNOLOGY SENSORPEDIA SENSORPEDIA www.acuitycontrols.com / 15 www.acuitycontrols.com ™ PIR & PDT

MICROPHONICS INFRARED PASSIVE TECHNOLOGY DUAL PASSIVE PDT DETECTION DETECTION

TECHNOLOGY

Better and more reliable occupancy detection reliable performance more Better and power less Requires Does not transmit sound waves into the space, eliminating potential for interference

• • • PDT is thePDT combination of two detection technologies, and PIR Microphonics™ The sensor will first“see” motion usingPassive Infrared, and then engages the Microphonics™ occupancy continued indicate sounds that “hear” to Patented by Sensor Switch, Passive Dual Technology using and PIR Microphonics is superior to technology ultrasonic used alternatively The suffix PDT after the enclosure model number adds Microphonics™ detectionto the sensor The sensor the heat “sees” given off by the human body as it moves in and out of the beams, and triggers the occupancy mode The sensors are fine-tunedto detect small motions even at great distances, while still preventing false trips All Sensor Switch sensors have technology PIR PIR sensorsPIR detect changes in the infrared energy given off by occupants as they move within the field-of-view of the sensor

• • Passive Dual Technology Dual Passive (PDT) • • • • • • Passive Infrared Technology Infrared Passive (PIR) This category specifies the detection Sensor by employed technologies Switch. There are two types of detection Passive and Infrared Passive technologies, Dual Technology. All sensors utilize PIR default. technology by PDT 16 SENSORPEDIA LENS TYPE /www.acuitycontrols.com SENSORPEDIA LWSH WSD WSX LWS and describe the applications for which they are best suited. best are they which for applications the describe and style lens each of pattern PIR coverage the diagram pages following The application. its also but requirements, area space’s the accommodates that pattern aPIR coverage with type alens to select important is It PASSIVE INFRARED LENS TYPE • • • Wall Lens Switch High Area Large Mount • • • Lens Switch Wall Area Large • • • Wall Lens Switch • • • Wall Switch Lens high mounting (121.92 in cm) 84 213.36 to to 48 coverage Wall-to-Wall (12.19 ft 40 to up m) detection movements) hand (e.g., motion Small high mounting 121.92 to cm) (76.20 in 48 to 30 coverage Wall-to-Wall (12.19 ft 40 to up m) detection movements) hand (e.g., motion Small coverage Wall-to-Wall (15.24 m) ft 50 to up detection walking) (e.g., motion Large (6.10 ft m) 20 to up detection movements) hand (e.g., motion Small coverage Wall-to-Wall (10.97 ~2025 m), ft ft sq 36 than greater detection walking) (e.g., motion Large (6.10 ft sq ~625 ft m), 20 to up detection movements) hand (e.g., motion Small 0ft 10 20 30 40 0ft 10 20 30 40 0 ft 10 20 0 ft 10 20 0 m 3 6 0 m 3 6 0 m 3 6 9.1 12.2 0 m 3 6 9.1 12.2 9.1 630m 369.1 30 20100ft 102030 20 10 9.1 630m 30 20100ft 6 30m 20 100ft 6 30m

0ft

3 6

36

10

10 20

TOP VIEW TOP TOP VIEW TOP 20

7 0 ft 1.2 m

4 ft VIEW TOP

2.1 0 m VIEW TOP t 0 0 3 40 20 30 10 9.1 12.2 6 0ft 3 0m t 0 0 3 40 20 30 10 9.112.2 6 0ft 3 0m 1.2 1.2 4 ft 4 ft m m 0 0 0 0 ft m ft m 9 3 9 3 18 18 6 6 27 27 9 9

12 12 36 36

SIDE VIEW SIDE VIEW SIDE SIDE VIEW SIDE SIDE VIEW SIDE LENS TYPE SENSORPEDIA 28 14 0 ft 14 28 28 14 0 ft 14 28 0 ft 15 30 45 12 6 0 ft 6 12 30 24 18 12 6 0 ft 6 12 18 24 30 18 15 12 9 6 3 0 ft 3 6 9 12 15 18 3.7 1.8 0 m 1.8 3.7 9.2 7.4 5.4 3.6 1.8 0 m 1.8 3.6 5.4 7.4 9.2 5.5 4.6 3.7 2.7 1.8 0.9 0 m 0.9 1.8 2.7 3.7 4.6 5.5 8.5 4.3 0 m 4.3 8.5 8.5 4.3 0 m 4.3 8.5 0 m 4.6 9.1 13.7 www.acuitycontrols.com / 17 www.acuitycontrols.com 9.1 6 3 0 m 3 6 9.1 30 20 10 0 ft 10 20 30 TOP VIEW TOP HIGH VIEW TOP VIEW TOP TOP VIEW TOP TOP VIEW TOP VIEW TOP 6 3 0 m 3 6 6 3 0 m 10 20 10 0 ft 20 18 15 12 9 6 3 0 ft 3 6 9 12 15 18 30 24 18 12 6 0 ft 6 12 18 24 30 5.4 4.6 3.6 2.7 1.8 0.9 0 m 0.9 1.8 2.7 3.6 4.6 5.4 9.2 7.4 5.4 3.6 1.8 0 m 1.8 3.6 5.4 7.4 9.2 3.7 1.8 0 m 1.8 3.7 12 6 0 ft 6 12 8.5 6.4 4.3 2.1 0 m 2.1 4.3 6.4 8.5 28 21 14 7 0 ft 7 14 21 28 8.5 6.4 4.3 2.1 0 m 2.1 4.3 6.4 8.5 28 21 14 7 0 ft 7 14 21 28 0 m 2.7 0 m 4.6 0 m 2.7 0 m 2.7 0 m 2.7 0 m 4.6 0 ft 9 0 ft 15 0 ft 9 0 ft 9 0 ft 9 0 ft 15 LOW VIEW SIDE VIEW SIDE VIEW LOW VIEW SIDE VIEW SIDE VIEW than view of field sensor’s across walking directly at sensor at directly walking Best choice for large motion detection walking) (e.g., Viewing angle of 67º for hallway applications Provides 28 ft (8.53 of m) coverage when mounted to standard ceiling 9 ft m) (2.74 to ft 4.577 to mounting 15 m) (2.13 heights provide to 36 16 ft (4.88 to hallway m) 10.97 coverage Best choice for large motion detection walking) (e.g., Viewing angle of 67º in a 360º conical shaped pattern Provides 28 ft (8.53 radial m) coverage when mounted to standard ceiling9 ft m) (2.74 to ft 4.577 to mounting 15 m) (2.13 heights provide to 36 16 ft (4.88 to radial m) 10.97 coverage Best choice for small motion (e.g., hand detectionmovements) Viewing angle of 56º in a 360º conical shaped pattern Provides ft 12 (3.66 radial m) coverage when mounted to standard ceiling 9 ft m) (2.74 ft8 to 15 (2.44 to 4.57 mounting m) heights provide to 10 20 ft (3.05 m) to 6.10 coverage radial Best choice for to 45 15 ft (4.57 mounting to m) 13.72 heights to 2015 ft radial (4.57 m) to 6.10 coverage overlaps area lit by a typical high bay fixture motion detectionExcellent large of (e.g., walking) up to a 35 ft m) (10.76 height mounting Excellent detection of extra large motion (e.g., forklifts) up to a 45 ft m) (13.72 height mounting motion walking for Recommended heights detection mounting from between 8 ft (2.44 and m) 20 m) ft (6.10 Initial detection of walking motion along sensor axes at distances of 2x the mounting height up ft to 15 (4.57 and m) up to1.75x 20 m) ft (6.10 Provides ft 12 (3.66 radial m) detection of small motion when mounted at 9 ft m) (2.74 Initial detection will occur earlier when walking • • • • Bi-Directional Hallway Lens • • • • Large / Extended Motion Range 360º Lens • • • • Small Motion / Standard / Standard Motion Small Range360º Lens Mini-Low Bay 360° Lens Bay Mini-Low • • • • • • • • High Bay 360º Lens Bay High 9 7 6 11 10 18 SENSORPEDIA LENS TYPE /www.acuitycontrols.com 30 16 13 50 • • Lens End-of-Hallway • • • Aisleway Lens High Bay Bi-Directional • • • Lens 360° Universal • • • Wide View 120° Lens at end of hall of end at (2.13 mounting 7ft m) high for Designed m) (39.62 130 ft to up detection walking) (e.g., motion Large direction (15.24 m) either in ft 50 detects (12.19 ft 40 m) mounting Typical direction either in range detection approximate 1.2x mounting height equals wide coverage pattern 10º and bi-directional 50º Provides a 30’ mounting height). @ less or center on 30’ fixtures (e.g., less or ratio height mounting to 1:1 spacing a have that fixtures for Recommended fixture bay high atypical by lit area overlaps coverage 6.10 to m) (4.57 radial ft 15 20 to 12.19 to (4.57 ft m) 15 40 to between motion (e.g., walking) when mounted Provides excellent of large detection corner room in mounting high m) 3.05 to (2.44 10 ft 8to for Designed m) (21.34 70 ft to up detection walking) (e.g., motion Large (12.19 ft 40 to up m) detection movements) hand (e.g., motion Small

SIDE VIEW SIDE VIEW 9 0 ft SIDE VIEW 40 30 20 10 0 ft SIDE VIEW 10 5 0 ft 40 30 20 10 0 ft 12.2 9.1 6 3 0 m 2.7 0 m 3 1.5 0 m 12.2 9.1 6.1 3 0 m 50250ft 50 52 76 0m7.615.2 7.6 15.2 t 0 0 3 40 20 12.2 30 10 9.1 6 0ft 3 0m 3 52 74 39.6 0ft105090130 0m315.227.4 6.1 20 0ft 0 m 6.1 TOP VIEW 7 0 ft 7 2.1 0 m 2.1 0ft 10 20 30 40 T TOP VIEW 10 0 ft 10 20 10 0 ft 10 20 TOP VIEW OP 50250ft 50 15.2 7.6 0m 7.6 15.2 7.6 15.2 VIEW 6.1 3 0 m 3 6.1 3 0 m 3 0 m 3 6 9.1 12.2 52 2. 39.6 0ft105090130 0m315.227.4 9.1 630m 30 20100ft OPTIONS SENSORPEDIA

P R LT SENSORPEDIA www.acuitycontrols.com / 19 www.acuitycontrols.com Features auto set-point calibration Fully digital, all settings in foot-candles Photocontrol has full control during periods of occupancy Recommended for public areas, such as vestibules, corridors, restrooms or Photocontrol can prevent lights from turning on if adequate daylight is available, but cannot turn lights off Recommended for areas where people work (private and open offices) Enables low voltage sensors to interface with a system management building Provides closure via an SPDT, 1 Amp, 40 Volt The relay is energized when ALL connected sensors register unoccupied When using multiple sensors, only one sensor per zone needs to have a relay During manufacturing, the circuit board goes through a conformal coating process, making it moisture resistant from corrosion Enablesoperating temperatures down to -40º (-40ºF C) for PIR sensors and -4º F (-20º C) for PDT sensors Ideal for cold storage applications or bath/shower steam condensing with rooms to function.to • • On/Offmode • • Inhibit mode • • R Low Isolated Relay Voltage • • • • Note: Sensor must have power at all times for the relay LT Low / Temperature High Humidity • • • P Photocontrol D HL DZ HVOLT OPTIONS

The datasheet for each sensor series lists its available options. Provides high/low control of a 0-10V dimmable fixture Lights are reduced to an energy saving minimum dim level after expiration of occupancy time delay If relay is wired, lights will switch off after a delay time second Allows sensor to be powered by and switch 347 through 480 VAC Used primarily in Fixture Mount Sensors Used only in Single Pole Devices Provides more advanced daylighting control for for control advanced daylighting more Provides voltage occupancy sensors line 2-Pole Single shared set-point is used for both poles Ideal for A/B (also called inboard/outboard) switching applications Determines the necessary on/off combination of the two poles in order to maintain adequate lighting Ideal for classrooms with individually controlled parallel rows of lights Uses a relative set-point for the second pole, which is a percentage of the first pole’s set-point Provides dimming output to control VDC 0-10 ballastsdimmable Provides a second occupancy time-out period that enables the lights to go to a dim setting before offturning Adjustable max/min dim setting When using multiple low voltage sensors, only one sensor per zone needs to have dimmingoutput • • • • HL Occupancy High/Low Operation • HVOLT VAC 347-480 • • Stepped Dimming Mode (DUO) • • Percentage Offset Mode (Dual Zone) • • DZ PhotocontrolDual Zone • D Occupancy Controlled Dimming • • • • ANL 347 ADC 2P SZ 2P AOP 2P AO included on the sensor. This section describes each option and its model number character suffix. version also includes switching The previous sections ofthis guide define the portion of the model number referredto as a sensor’s series number. Provides maximum energy savings by first dimming down, then switching off, lighting during periods of sufficient daylight contribution from windows or skylights During unoccupied periods without sufficient daylight lights are dropped to low dim setting, insuring minimum light levels are maintained at night Controls 0-10V dimmable fluorescent ballasts and LED drivers Photocontrol within sensor maintains total room light level by controlling levels of VDC 0-10 ballastsdimmable Photocontrol also has full on/off control during periods of occupancy Provides a second occupancy time-out period that enables the lights to go to a dim setting before offturning Allows sensor to be powered by and switch 347 VAC Used primarily in Canada Occupancy controls one pole only pole Occupancy one controls pole other controls photocontrol Switching Sequence of operation where both relays close during periods of occupancy, but only one opens vacancyduring The relay left closed alternates in order to promote even lamp wear 2P AOP photocontrol Following this series number, there may be additional characters in the model number that define the optional features • • • ANL Combination Dimming & w/ Photocontrol Switching High/Low Occupancy Operation • • • ADC Photocontrol w/ Auto Dimming 347 347 VAC • • • 2P-SZ Pole Single Photocontrol Switching • 2P AO & 2P AOP & 2P AO 2P OffAlternating Relays • • • 20 / www.acuitycontrols.com PRODUCT SELECTION GUIDE

22 WALL SWITCH CONTROLS

32 WIRELESS PRODUCTS

34 CEILING MOUNT SENSORS

38 CEILING MOUNT DAYLIGHT CONTROLS

40 RECESSED MOUNT SENSORS

42 RECESSED MOUNT DAYLIGHT CONTROLS

44 FIXTURE MOUNT SENSORS

48 FIXTURE MOUNT DAYLIGHT CONTROLS

50 FIXTURE MOUNT INTERCHANGEABLE LENS SENSORS

54 FIXTURE MOUNT INTERCHANGEABLE LENS DAYLIGHT CONTROLS

56 WIDE VIEW & HALLWAY SENSORS

58 OUTDOOR SENSORS

60 POWER PACKS

62 MICRO ENCLOSURE

64 SNAP-FIT

69 EMBEDDED

www.acuitycontrols.com / 21 22 PRODUCT SELECTION GUIDE WALL SWITCH CONTROLS /www.acuitycontrols.com Wall Switch Sensor Wall Switch FAMILY WSX COVERAGE PATTERN ADDITIONAL INFORMATION INFORMATION PRODUCT SIZE MOUNTING HEIGHT: 30-48” (76.2-121.9 cm) 30-48” HEIGHT: MOUNTING MOUNTING WEIGHT WSX :  2.74" H x 1.68" W x 1.63" D D Wx1.63" 2.74" Hx1.68" (not including ground strap) strap) ground including (not x4.14 cm cm) x4.27 (6.96 cm : 5oz : Single gang switch box switch gang : Single • • • • Lens Switch Wall keeping the lights on lights the keeping from noises non-occupant prevent to utilized is filtering advanced area; coverage PIR complete the over activity human of detection overlapping provides (Microphonics™) Technology Dual Passive coverage Wall-to-Wall (10.97 ~2025 m), ft ft sq 36 than greater detection walking) (e.g., motion Large (6.10 ft sq ~625 ft m), 20 to up detection movements) hand (e.g., motion Small PHYSICAL

For additionalproduct information, visitwww.acuitycontrols.com. (RELAY): LOAD/POLE MAXIMUM WIRING DIAGRAM(S): SeeFigure #1, 2, 3, 4onPage 82 Hz 50/60 FREQUENCY: 1/4 Hp LOAD: MOTOR None LOAD: MINIMUM residential applications. applications. residential and restrooms for -perfect light night integrated an with units and applications, bi-level for -perfect relays dual with units include versions Additional obstructions. with rooms and offices for recommended are and detection Microphonics™ add versions option) (PDT Technology Dual detection. (PIR) Infrared Passive digital 100% utilize sensors Family WSX All seconds. in unit the convert can contractors code, by required is neutral to connection if however, aneutral; without wiring for pre-configured come units WSX connection. aneutral without or with either function to them enables that method wiring pending apatent have sensors Family WSX all Additionally, space. enclosed small other any or rooms, copy closets, rooms, rest private offices, private for perfect them (6.10 making m), ft 20 to up detection motion small provide and buttons, soft-click appearance, profile low astylish have sensors Family WSX All applications. control lighting residential and commercial for solutions effective cost and simple provides sensors occupancy switch wall of Family WSX The Overview 1200 W @ 277 VAC W@277 1200 1500 W @ 347 VAC W@347 1500 0 ft 10 20 800 W@120 VAC 800 0 m 3 6 20 10 6 30m SPECIFICATIONS

ELECTRICAL

0ft

3 6

10

20

RELATIVE HUMIDITY: RELATIVE TEMP: OPERATING ROHS COMPLIANT ROHS

TOP VIEW TOP • • • • • • • • • • • Features White LED status Indicator Indicator status LED White modes &operating delays time -adjustable plate cover removing without programmable Push-button default) by (disabled standard Photocontrol &incandescents CFLs, ballasts, &magnetic electronic LEDs, w/ Compatible neutral to connected when ground to leakage current -no requirements neutral 404.2C 2011 Section NEC meets Fully systems building other with interference for potential no detection, passive 100% standard lens resistant vandal assembly, Ruggedized immunity RF -excellent detection PIR Digital neutral Convertible connections &load line reversible protection, Miswire detection Microphonics™ PIR/ utilizes (PDT) Technology Dual Passive LT Option (PDT): -4° to 122°F (-20° to 50°C) to (-20° 122°F to -4° (PDT): Option LT 50°C) to (-40° 122°F to -40° (PIR): Option LT (-10° 50°C) to 122°F 14° to Standard: (electronics coated for corrosion resistance) corrosion for coated (electronics non-condensing 90% to 20 Option: LT non-condensing 75% to 20 Standard: 1.2 4 ft m 0 0 ft m

ENVIRONMENTAL 9 3 18 6 Wall Switch Sensors Wall Switch

27 9

12 36 SIDE VIEW SIDE

WALL SWITCH CONTROLS PRODUCT SELECTION GUIDE

WSX PDT WH WSX PDT NL WH www.acuitycontrols.com / 23 www.acuitycontrols.com Standard Low Temp/ High Humidity Standard Low Temp/ High Humidity Wall SwitchWall Sensors WSX 2SA 2P 347 WH LT Example:

Example: (blank) (blank) LT (blank) LT Temp/Humidity Temp/Humidity Example: Standard Low Temp/High Humidity

(blank) (blank) LT Temp/Humidity Night Light Night White Ivory Gray Light Almond Black Red White Ivory Gray Light Almond Black Red

3 3 Ideal for bathrooms (hotel/hospital) or residential applications Ultra low power WhiteLED night light (24/7 operation) Capable of powering over Ground Neutral (no required) Manual On/Auto off operation of lights (default) Available with Single or Dual Relays

NL WH IV GY AL BK RD WH IV GY AL BK RD Color Color • • • • • Operating modes reprogrammable via push-button except for VA version VA for except via push-button modes reprogrammable 1. Operating units VAC plates included in white or ivory only for 347 Wall 2. units VAC for 120/277 3. Matching wall plate provided mode (Manual On) Operating Vacancy 4. Units factory set to

Notes

2 2 120/277 VAC 347 VAC 120/277 VAC 347 VAC White Ivory Gray Light Almond Black Red

3 WH IV GY AL BK RD Color (blank) 347 (blank) 347 Voltage Voltage 2 120/277 VAC 347 VAC

Dual Relay

1 lights on Pole 1 and VAC 120 fan on Pole2 Ideal for bi-level switched rooms or restroom with light & fan Includes two isolated relays, Pole 1 defaulted to Auto On, Pole 2 to Vacancy Enables separate time delay per pole - programmed via each pole’s push-button UL Listed to switch different loads per pole - e.g. 277 VAC 347 (blank) Voltage 1 2P • • • • Auto-On (default) or Vacancy Vacancy (default) or Auto-On Vacancy only Pole 1 Auto-On Pole 2 Vacancy (default) Both Poles Vacancy (default) or Auto-On Both Poles Vacancy only (blank) SA VA Operating mode (blank) 2SA 2VA Operating mode Specifications subject to change. Specifications subject to change. Specifications subject to change. Passive Infrared (PIR) Dual Technology (PIR/Microphonics™) Dual Relay, Passive Infrared (PIR) Dual Relay, Dual Technology (PIR/Microphonics™) Passive Infrared (PIR) Dual Technology (PIR/Microphonics™) Passive Infrared (PIR) Dual Technology (PIR/Microphonics™) Low Temp/High HumidityLow Temp/High 347 Voltage 347

4 Required for cold/humid areas Sensor electronics are coated for corrosion resistance Operates down to -40°F/C (-4°F/-20°C for PDT) Allows sensor to be powered from and switch 347 VAC Cover plate for 347 VAC sensors included LT 347 OPTION INFORMATION NIGHT LIGHT NIGHT DUAL RELAY DUAL SINGLE RELAYSINGLE WSX NL WSX PDT NL WSX NL 2P WSX PDT NL 2P WSX 2P WSX PDT 2P WSX WSX PDT PRODUCT INFORMATION Series Series Series • • • • • 24 PRODUCT SELECTION GUIDE WALL SWITCH CONTROLS /www.acuitycontrols.com Wall Switch Sensor Wall Switch FAMILY WSD PRODUCT INFORMATION PRODUCT ADDITIONAL INFORMATION COVERAGE PATTERN MOUNTING HEIGHT: 30-48” (76.2-121.9 cm) 30-48” HEIGHT: MOUNTING MOUNTING WEIGHT SIZE WSD :  (not including ground strap) strap) ground including (not x4.14 cm cm) x4.27 (6.96 cm D Wx1.63" 2.74" Hx1.68" : 5oz : Single gang switch box switch gang : Single • • • Wall Switch Lens Switch Wall Wall-to-Wall coverage Wall-to-Wall (15.24 m) ft 50 to up detection walking) (e.g., motion Large (6.10 ft m) 20 to up detection movements) hand (e.g., motion Small PHYSICAL

For additionalproduct information, visitwww.acuitycontrols.com. MAXIMUM LOAD/POLE (RELAY): LOAD/POLE MAXIMUM

WIRING DIAGRAM(S): SeeFigure #1, 2, 3, 4onPage 82 Hz 50/60 FREQUENCY: 1/4 Hp LOAD: MOTOR None LOAD: MINIMUM unit in seconds. in unit the convert can contractors code, by required is neutral to connection if however, aneutral; without wiring for pre-configured come units WSD connection. aneutral without or with either function to them enables that method wiring pending apatent have sensors Family WSD all Additionally, recommended. is sensor Series PDT WSD Technology Dual the obstructions, with rooms For push-button. front the using programmed be can that Modes Switch and Modes On several has sensor WSD the Additionally, use. to simple and install, to easy are sensors occupancy switch wall Switch’s Sensor of All obstructions. without space enclosed small any or closets, rooms, copy offices, private for perfect are sensors switch wall of line This Technology. Dual Passive optional as well as technology detection (PIR) Infrared Passive powerful with horse work areliable is sensor switch wall WSD The Overview 1200 W @ 277 VAC W@277 1200 1500 W @ 347 VAC W@347 1500 0 ft 10 20 800 W@120 VAC 800 0 m 3 6 20 100ft 6 30m SPECIFICATIONS

ELECTRICAL

36

10 20 ROHS COMPLIANT ROHS HUMIDITY: RELATIVE

TEMP: OPERATING

• • • • • • • • • • Features

TOP VIEW TOP Green LED status Indicator Indicator status LED Green modes &operating delays time -adjustable plate cover removing without programmable Push-button &incandescents CFLs, ballasts, &magnetic electronic LEDs, w/ Compatible default) by (disabled standard Photocontrol strap mounting Self-grounding ft 20 to detection motion Small immunity RF -excellent detection PIR Digital neutral Convertible connections &load line reversible protection, Miswire detection Microphonics™ PIR/ utilizes (PDT) Technology Dual Passive (electronics coated for corrosion resistance) corrosion for coated (electronics non-condensing 90% to 20 Option: LT non-condensing 75% to 20 Standard: 50°C) to (-20° 122°F to -4° (PDT): Option LT 50°C) to (-40° 122°F to -40° (PIR): Option LT Standard: 14° to 122°F (-10° 50°C) to 122°F 14° to Standard: 1.2 4 ft m 0 0 ft m

ENVIRONMENTAL 9 3 18 6 Wall Switch Sensors Wall Switch

27 9

12 36 SIDE VIEW SIDE

WALL SWITCH CONTROLS PRODUCT SELECTION GUIDE WSD PDT WH WSD PDT 2SA 2P WH www.acuitycontrols.com / 25 www.acuitycontrols.com Wall SwitchWall Sensors Standard Low Temp/High Humidity Example: Standard Low Temp/High Humidity

Example: (blank) (blank) LT Temp/Humidity (blank) (blank) LT Temp/Humidity White Ivory Gray Light Almond Black

3 White Ivory Gray Light Almond Black

3 WH IV GY AL BK Color WH IV GY AL BK Color Operating modes reprogrammable via push-button except for VA version VA for except via push-button modes reprogrammable 1. Operating units VAC plates included in white or ivory only for 347 Wall 2. units VAC for 120/277 3. Matching wall plate provided Notes

2 120/277 VAC 347 VAC 2 120/277 VAC 347 VAC (blank) 347 Voltage (blank) 347 Voltage

Dual Relay

Ideal for bi-level switched rooms or restroom with light & fan Includes two isolated relays, Pole 1 defaulted to Auto On, Pole 2 to Vacancy Enables separate time delay per pole - programmed via each pole’s push-button UL Listed to switch different loads per pole - e.g. 277 VAC lights on Pole 1 and VAC 120 fan on Pole2 1 1 2P • • • • Pole 1 Auto-On Pole 2 Vacancy (default) Both Poles Vacancy (default) or Auto On Auto-On (default) or Vacancy Vacancy (default) or Auto-On Vacancy only (blank) 2SA Operating mode (blank) SA VA Operating mode Specifications subject to change. Specifications subject to change. Passive Infrared (PIR) Dual Technology (PIR/Microphonics™) Passive Infrared (PIR) Dual Technology (PIR/Microphonics™) Low Temp/High HumidityLow Temp/High 347 Voltage 347

Allows sensor to be powered from and switch 347 VAC Cover plate for 347 VAC sensors included Required for cold/humid areas Sensor electronics are coated for corrosion resistance Operates down to -40°F/C (-4°F/-20°C for PDT) LT 347 DUAL RELAY DUAL OPTION INFORMATION SINGLE RELAYSINGLE WSD 2P WSD PDT 2P WSD WSD PDT PRODUCT INFORMATION Series Series • • • • • 26 PRODUCT SELECTION GUIDE WALL SWITCH CONTROLS /www.acuitycontrols.com Wall Switch Sensor Wall Switch SSD Series COVERAGE PATTERN INFORMATION PRODUCT ORDERING INFORMATION ADDITIONAL INFORMATION SSD SSD MOUNTING HEIGHT: 30-48 in (76.2-121.9 in cm) 30-48 HEIGHT: MOUNTING Box Switch Gang Single MOUNTING: 5oz WEIGHT: SIZE: (not including ground strap) strap) ground including (not x4.14 cm cm) x4.27 (6.96 cm x1.63”D 2.74”H x1.68”W Passive Infrared (PIR) Infrared Passive • • • Lens Switch Wall *Cover Plate Not Included Not Plate *Cover Wall-to-Wall coverage Wall-to-Wall (15.24 m) ft 50 to up detection walking) (e.g., motion Large (6.10 ft m) 20 to up detection movements) hand (e.g., motion Small PHYSICAL Specifications subjecttochange. For additionalproduct information, visitwww.acuitycontrols.com. Operating Mode Operating (blank) VA SA Vacancy only Vacancy On Auto or (default) Vacancy Vacancy or (default) On Auto 1 WIRING DIAGRAM(S): SeeFigure #5onPage 83 Hz) 50 for 1.2x are (timers Hz 50/60 FREQUENCY: 1/4 HP LOAD: MOTOR None LOAD: MINIMUM LOAD MAXIMUM desired. if utilized be to default) by (disabled time on minimum additional an providing sensors, these in present also is technology LampMaximizer® Patented re-detected. is occupancy time every reset is and minutes, 30 to seconds 30 from programmable is timer This false-offs. preventing while savings energy maximize to order in -chosen 10 minutes is delay time default The automatically. off turned are lights expired, has delay time the Once inactivity. of periods brief during on them keeps timer internal an on, turned are lights the After on. lights the initiate to pressed be first must button push unit’s the On) sensor, (Vacancy/Manual VA SSD an In load. lighting connected the on switches relay internal an detected, is occupancy Once view. field-of- the within move they as occupants by off given energy (PIR) Infrared Passive the in changes detect sensors SSD Operation Sensor lights. the off turn and out time will sensor the vacated is room the once that ensures delay time programmable Auser obstructions. without space enclosed small any or closets, rooms, copy offices, private for ideal is It use. to simple and install to easy is sensor switch wall The technology. detection (PIR) Infrared Passive powerful with sensor switch wall effective acost is SSD The Overview 0 ft 10 20 Fluorescent/Incandescent loads only Fluorescent/Incandescent VAC W@277 1200 800 W@120 VAC 800 0 m 3 6 20 100ft 6 30m SPECIFICATIONS ELECTRICAL Voltage

120 (blank)

36

120 VAC only 120 VAC VAC 120/277 10 20 2. 1. Notes: Operating Modes reprogrammable via push-button except for VA version VA for except push-button via reprogrammable Modes Operating Cover Plate Not Included Not Plate Cover

ROHS COMPLIANT ROHS HUMIDITY: RELATIVE TEMP OPERATING • • • • • • • • • • • • Features

TOP VIEW TOP Green LED status Indicator status LED Green memory settings Non-volatile default by -disabled life lamp Fluorescent increased provides (patented) time on minimum LampMaximizer® Integrated modes &operating delays time -adjustable plate cover removing without programmable Push-button Incandescents & CFLs, Ballasts, &Magnetic Electronic w/ Compatible load to leakage current no and load minimum No required connection neutral No strap mounting Self-grounding ft 20 to detection motion Small immunity RF -excellent detection PIR connections &load line reversible protection, Miswire 20 to 75% non-condensing 75% to 20 C) F(-10º 50º 122º 14º to to 1.2 4 ft m 0 0 ft m ENVIRONMENTAL Color 9 3 IV WH 2 Ivory White 18 6 Wall Switch Sensors Wall Switch Example: 27 9

SSD WH SSD

12 36 SIDE VIEW SIDE

WALL SWITCH CONTROLS PRODUCT SELECTION GUIDE

SIDE VIEW 36 12 9 27 WSD R WH LV LT www.acuitycontrols.com / 27 www.acuitycontrols.com Wall SwitchWall Sensors 6 18 Wall SwitchWall Sensor WSD LV Example: Standard Low Temp/High Humidity

3 9 ENVIRONMENTAL (blank) (blank) LT Temp/Humidity m ft 0 0 m 4 ft 1.2 14º to14º 160º to C)71º F (-10º to 160º to C) 71º -14º F (-26º 20 to 90% non-condensing TOP VIEW

OPERATINGTEMP: STORAGE TEMP: RELATIVEHUMIDITY: ROHS COMPLIANT Permanent Off - Pressing thepush-button switch will turn the lights off. The lights will remain off regardless of occupancy until the switch is pressed again, restoring the sensor to Automatic On mode. Switch Disable - Prevents user from manually turning off the lights via the push-button. 20 Light Almond Black

AL BK 10

3 6

Low Temp/High HumidityLow Temp/High

Required for cold/humid areas Sensor electronics are coated for corrosion resistance Operates down to -40°F/C (-4°F/-20°C for PDT) LT White Ivory Gray • • •

WH IV GY Color ELECTRICAL SPECIFICATIONS 6 3 0 m 20 10 0 ft 6 3 0 m 800 VAC W @ 120 1200 W @ 277 VAC 1500 W @ 347 VAC 20 10 0 ft PIR Occupancy Detection - excellent RF immunity Small Motion Detection up to 20 ft (6.10m) 30 sec to 20 min Time Delay Push-ButtonProgrammable Green LED status Indicator occupancy is detected, a self-contained relay switches the connected lighting load on. The sensor is line powered and can switch a range of line voltages.An internal timer, factory set at minutes, 10 keeps the lights on during brief periods of inactivity. This timer is push-button programmable from 30 seconds to 20 minutes, and is reset every time occupancy is re-detected. This state-of-the-art design requires no field calibration or sensitivity adjustments. Features • • • • • Switch Modes (Default) Predictive Off - Pressing the switch overrides the lights off and temporarily disables the occupancy detection. After an exit time delay (default seconds) 10 the occupancy detection reactivates and monitors for anadditional grace period time (default 5 seconds). If no occupancy is detected during this period, the sensor will revert to Automatic On operation. If occupancy is detected, the sensor will remain in Permanent Off mode requiring the switch to be pressed again in order to restore the sensorto Automatic On. MINIMUM LOAD: None MOTOR LOAD: HP 1/4 FREQUENCY: 50/60 Hz 83 # 7 on Page : See Figure WIRING DIAGRAM(S) MAXIMUM LOAD: None Low Voltage Relay (blank) R Relay For additional product information, visit www.acuitycontrols.com. information, additional product For Specifications subject to change. PHYSICAL PHYSICAL Small motion (e.g., hand movements) detection up to 20 m) ft (6.10 Large motion (e.g., walking) detection up to 50 ft m) (15.24 Wall-to-Wall coverage Passive Dual Technology (Microphonics™) provides overlapping detection of human activity over the complete PIR coverage area; advanced filtering is utilized to prevent non- occupant noises from keeping the lights on Passive Infrared (PIR) Dual Technology (PDT) Wall Switch Lens • • • • (6.96cm x 4.27cm x 4.14cm) cm) (76.2 - 121.9 Low Voltage Relay Voltage Low

Enables sensors to interface with other systems (e.g. BMS, lighting panels) Provides dry contact closure via a SPDT, 1 amp, 30 volt relay (resistive loads only) SIZE: x 1.68”W 2.74”H x 1.63”D WEIGHT: 5 oz MOUNTING: Single Gang Switch Box MOUNTING HEIGHT: 30-48 in COLORS: White, Ivory, Gray, Lt. Almond, Black R WSD OPTION INFORMATION COVERAGE PATTERN COVERAGE OPERATIONAL MODESOPERATIONAL ORDERING INFORMATION ORDERING ADDITIONAL INFORMATION ADDITIONAL PRODUCT INFORMATION WSD LV WSD PDT LV Series Overview The WSD Series LV is a low voltage wall switch occupancy sensor that is stylish, easy to install, and simple to use. Ideal for private offices, copy rooms, closets, or any small enclosed space without obstructions, the WSD uses LV the industry’s best Passive Infrared (PIR) technology to achieve excellent small motion detection up to 20 ft. A user programmable time delay ensures that once the room is vacated the sensor will time out and turn off the lights. WSD sensors LV also have additional On Modes and Switch Modes that are all fully programmable using the front push-button. For rooms with obstructions theWSD PDT should LV be considered. Sensor Operation The sensor detects changes in the infrared energy given off by occupants as they move within the field-of-view. When On Modes (Default) Modes On Automatic On - The sensor automatically turns the lights on when the sensor detects occupancy. Reduced Turn-On - The sensor is set to initially only detect large motions, effectively ignoring any reflected PIR signals while still sensing occupants when they enter the room. Once on, the sensor returns to maximum sensitivity. • • 28 PRODUCT SELECTION GUIDE WALL SWITCH CONTROLS /www.acuitycontrols.com Large Area Wall Sensor Area Switch Large LWS(H) LWSH PRODUCT INFORMATION PRODUCT COVERAGE PATTERN LWS • • • • Lens Switch Wall Mount High Area Large • • • • Lens Switch Wall Area Large lights on lights the keeping from noises occupant non- prevent to utilized is filtering advanced area; coverage PIR complete the over activity human of detection overlapping provides (Microphonics™) Technology Dual Passive high mounting (121.92 in cm) 84 213.36 to to 48 coverage Wall-to-Wall (12.19 ft 40 to up m) detection movements) hand (e.g., motion Small on lights the keeping from noises occupant non- prevent to utilized is filtering advanced area; coverage PIR complete the over activity human of detection overlapping provides (Microphonics™) Technology Dual Passive high mounting 121.92 to cm) (76.20 in 48 to 30 coverage Wall-to-Wall (12.19 ft 40 to up m) detection movements) hand (e.g., motion Small one or two poles. poles. two or one with available and powered line are Series LWSH and LWS The obstructions. with rooms for detection (PIR/Microphonics™) Technology Dual or detection (PIR) Infrared Passive either with available are 2.13 to (1.22 styles All m). 7ft 4to from mount surface sensors Series LWSH the while height, switch standard at mount surface sensors Series LWS The prohibitive. cost is systems voltage alow installing where and needed, is sensor’s adecorator than larger pattern acoverage where spaces open or centers storage large classrooms, retrofitting when use to products ideal are sensors Switch Wall Area Large Overview 0ft 10 20 30 40 0ft 10 20 30 40 0 m 3 6 9.1 12.2 0 m 3 6 9.1 12.2

9.1 630m 9.1 630m 30 20100ft 30 20100ft

TOP VIEW TOP TOP VIEW TOP 7 0 ft 1.2 m 4 ft • • • • • • • Features 2.1 0 m t 0 0 3 40 20 30 10 9.112.2 6 0ft 3 0m t 0 0 3 40 20 30 10 9.112.2 6 0ft 3 0m Green LED status Indicator Indicator status LED Green Delay Time Adjustable Load Minimum No Compatible Switching &4-Way 3-Way Required Pack(s) Power No Relay(s), Self-Contained (12.19 ft 40 to up m) detection Motion Small connections &load line reversible protection, Miswire

Large Area Wall Switch Sensor Wall Switch Area Large

SIDE VIEW SIDE SIDE VIEW SIDE WALL SWITCH CONTROLS PRODUCT SELECTION GUIDE

LSW WH 2P www.acuitycontrols.com / 29 www.acuitycontrols.com Example: White Ivory WH IV Large Area Switch Wall Sensor Color ENVIRONMENTAL WS BPX3 I/W 14º to14º to 85º 29º(-10º F C) to 160º to C) 71º -14º F (-26º 20 to 90% non-condensing versions) (non-Photocontrol OPERATINGTEMP: STORAGE TEMP: RELATIVEHUMIDITY: ROHS COMPLIANT 120/277 VAC 347 VAC (blank) 347 Voltage WS BPX I/W ELECTRICAL SPECIFICATIONS 1-Pole 2-Pole 13 Amps13 @ 120-347 VAC Timers are 1.2 x for 50 Hz 2P (blank) FREQUENCY: 50/60 Hz MOTOR LOAD: HP 1/4 each pole 86 on Page # 15 & 16 : See Figure WIRING DIAGRAM(S) MAX LOAD / POLE: Phase (1 Only) # of Poles WS SPX3 I/W For additional product information, visit www.acuitycontrols.com. information, additional product For For additional product information, visit www.acuitycontrols.com. information, additional product For Specifications subject to change. PHYSICAL PHYSICAL

WS SPX I/W Surface Mount oltage Passive Infrared (PIR) Dual Technology (PDT) Passive Infrared (PIR) Dual Technology (PDT) plate comes with the 2-pole models. Others can be ordered separately. 4.96”H x 3.10”W4.96”H x 1.70” D cm(12.60 cm x 4.32 x 7.87 cm) LWS: 30-48“ cm) ( 76.2-121.92 LWSH: 48-84” cm) (121.92-213.36 347 V

Allows sensor to be powered and switch 347 VAC WEIGHT: 7 oz MOUNTING: Single Gang Switch Box HEIGHT: MOUNTING COLOR: White, Ivory SIZE: ENCLOSURE: LWS LWS PDT LWSH LWSH PDT 347 OPTION INFORMATION OPTIONAL WALL PLATES WALL OPTIONAL ORDERING INFORMATION ORDERING ADDITIONAL INFORMATION ADDITIONAL PRODUCT INFORMATION Series • The WS BPX 30 PRODUCT SELECTION GUIDE WALL SWITCH CONTROLS /www.acuitycontrols.com Sensor Interface Switch Interface Sensor SWITCHPOD Series ORDERING INFORMATION ADDITIONAL INFORMATION INFORMATION PRODUCT MOUNTING: 2oz WEIGHT: D Wx1.63" 2.74" Hx1.68" SIZE: SPODM (not including ground strap) ground including (not x4.14 cm cm) x4.27 (6.96 cm Single gang switch box or low voltage ring voltage low or box switch gang Single Sensor Interface Switch Interface Sensor PHYSICAL

Specifications subjecttochange.

For additionalproduct information, visitwww.acuitycontrols.com. Dimming D (blank) 1 (0-10VDC) Operation Dimming None WIRING DIAGRAM(S): SeeFigure #35, 36, 37, 38onPage 92-93 PP20 PACK: POWER RECOMMENDED DIMMING LOAD 5mA DRAW: CURRENT 12-24 VAC/VDC VOLTAGE: OPERATING necessary. are sensors and packs, power (WallPods), stations wall Enabled nLight applications, lighting bi-level to solutions digital For available. also are operation manual-on dual to defaulted Units output. dimming VDC a0-10 have and/or applications 3-way in work that available also are Versions units. switch dual or single as available devices style decorator gang single all are SwitchPods packs. power or sensors special source to having without codes building and energy meet that control lighting bi-level deploying of way cost-effective and elegant an provide devices switch These applications. switching bi-level and single of range awide implement to order in packs power and sensors occupancy Switch Sensor with interface stations wall voltage low of Series (SPODM) SwitchPod Push-Button The Overview ~40 Ballasts / Drivers @ 0.5 mA each mA @0.5 /Drivers Ballasts ~40 # of Switches/Default on Operation Operation on Switches/Default # of 2P 2SA 2P SA (blank) :  0-10 VDC, Sinks < 20 mA; mA; <20 Sinks 0-10 VDC, 2 Switches (both Manual) (both 2 Switches 2Auto) Manual/Switch 1 (Switch 2 Switches On 1 Switch/Manual On 1 Switch/Auto SPECIFICATIONS ELECTRICAL Multi-way 3X (blank) (e.g. 3-way) (e.g. Multi-way None 1 ROHS COMPLIANT ROHS HUMIDITY: RELATIVE

TEMP: OPERATING

• Features • • • • • • • LT Option: 20 to 90% non-condensing 90% to 20 Option: LT non-condensing 75% to 20 Standard: 50°C) to (-40° 122°F to -40° Option: LT Standard: 14° to 122°F (-10° 50°C) to 122°F 14° to Standard: Optional 0-10 VDC dimming control dimming 0-10 VDC Optional etc.) 4-way, 3-way, (i.e., configurations multi-way for unit enables option 3X Optional dual operation manual-on plate switch removing without Programmable Finger-touch control switches on/off 2 1or with enclosure style decorator gang Single applications auto-on for switch override as usage Alternative applications manual-on for sensors occupancy standard with Used Color BK AL GY IV WH

Black Almond Light Gray Ivory White

Notes Not available with 2 switch (2P) versions 1. Notavailablewith2switch(2P)versions ENVIRONMENTAL Temp/Humidity Low Voltage Switches Voltage Low LT (blank) Example:

Humidity High Temp/ Low Standard SPODM WH SPODM

WALL SWITCH CONTROLS PRODUCT SELECTION GUIDE

PTS 60 WH

www.acuitycontrols.com / 31 www.acuitycontrols.com Example: Preset Timer Switches Standard Low Temp/High Humidity SWITCHES ENVIRONMENTAL (blank) LT

Temp/Humidity

PRESET TIMER PRESET Standard: to 14° 122°F to 50°C) (-10° LT Option: 20 to 90% non-condensing LT Option: -40° to 122°F (-40° to 50°C) Standard: 20 to 75% non-condensing See data sheet for LED specifications OPERATINGTEMP: ROHS COMPLIANT RELATIVEHUMIDITY: Load specifications for fluorescent and incandescent lighting only specifications for fluorescent 1. Load Notes White Ivory Gray Light Almond Black WH IV GY AL BK Color ELECTRICAL

SPECIFICATIONS 120/277 VAC 347 VAC : 1 (blank) 347 Voltage 800 VAC W @ 120 1200 W @ 277 VAC 1500 W @ 347 VAC Miswire protection, reversible line & load connections required connection neutral No No minimumload requirement Self-containedrelay Fixed or adjustable preset times Optional audible timeout warning at 45, 30, and sec 15 Optional flicker timeout warning at 2 and 1 min Continuous led flash for last 30 sec of button’s setting time Green LED time Indicators • • • • • • • • Features • MAXIMUM LOAD

MINIMUM LOAD: None MOTOR LOAD: HP 1/4 FREQUENCY: 50/60 Hz 83 # 6 on Page : See Figure WIRING DIAGRAM(S)

60 min. max 720 min. max 60 720 Time ScaleTime For additional product information, visit www.acuitycontrols.com. information, additional product For Specifications subject to change.

PHYSICAL PHYSICAL Single Gang Switch Box Preset Timer Switch (6.96 cm(6.96 x 4.27 cm) cm x 4.14 (not including ground strap) PTS SIZE: H x 1.68" 2.74" W x 1.63" D WEIGHT: 5 oz MOUNTING: ORDERING INFORMATION ORDERING ADDITIONAL INFORMATION ADDITIONAL PRODUCT INFORMATION Series Overview The PTS 60 and PTS 720 Series preset timer switches provide a simple to use and simple to apply lighting control alternative to wall switch occupancy sensors. These elegant decorator style wall stations each provide six preset countdown timer selections as wellas an on/off push-button. The PTS 60 and PTS 720 units are powered from 120/277 VAC (optional 347 VAC) and are intended to switcha line voltage lighting load or small motor load (see specifications). Additionally, the PTS 60 and PTS 720 can be applied without requiring a neutral wiring connection, making them ideal for applications. retrofit PRODUCT INFORMATION Wireless Sensors

Overview Features WIRELESS Sensor Switch's CM (PDT) xx WR Series of wireless • Passive Dual Technology (PDT) utilizes PIR/ occupancy sensors provide both Passive Infrared (PIR) and Microphonics™ detection Microphonics™ Dual Technology detection options. These PRODUCTS • 100% wireless operation battery operated sensors (with an estimated 10 year battery Occupancy Sensors life) utilize RDT Wireless technology. They are designed to • RDT™ 902 MHz compliant work with the SPODMR WR Series wall switch or other RDT • 10-year battery life (at defaults) Wireless devices to control a space's lighting. • 360° coverage pattern WIRELESS PRODUCTS • Digital PIR detection - excellent RF immunity • Simple push-button pairing

COVERAGE PATTERN

9 Small Motion / Standard Range 360º Lens TOP VIEWTOP VIEW • Best choice for small motion 3.7 123.7 12 (e.g. hand movements) detection SIDE VIEWSIDE VIEW • 360° conical shaped pattern 1.6 61.6 6 0 ft 0 ft • Provides ~12 ft (3.66 m) radial coverage 0 m 0 m 2 (~500 ft ) when mounted to standard 0 m 0 0ft m 0 ft 9 ft (2.74 m) ceiling 9 2.79 2.7 • 8 to 15 ft (2.44 to 4.57 m) mounting 1.6 61.6 6 heights provide ~10 to 20 ft 3.7 3.7 1.8 1.8 0 m 0 m 1.8 1.8 3.7 3.7 (3.05 to 6.10 m) radial coverage 12 12 6 6 0 ft 0 ft 6 6 12 12 3.7 123.7 12 • Passive Dual Technology (Microphonics™) provides overlapping detection of human activity over the complete PIR coverage area; advanced filtering is utilized to prevent non-occupant noises from keeping the lights on

10 Large Motion / Extended Range 360º Lens TOP VIEW • Best choice for large motion detection (e.g. 8.5 28 walking) SIDE VIEW • 360° conical shaped pattern 4.3 14 0 ft 0 m • Provides ~24 ft (7.32 m) radial 2 coverage (~2000 ft ) when mounted 0 m 0 ft at 9 ft (2.74 m) 9 2.7 • 7 to 15 ft (2.13 to 4.57 m) mounting heights 4.3 14 8.5 6.4 4.3 2.1 0 m 2.1 4.3 6.4 8.5

PRODUCT SELECTION GUIDE SELECTION PRODUCT provide ~16 to 36 ft (4.88 to 10.97 m) radial coverage 28 21 14 7 0 ft 7 14 21 28 8.5 28 • Detection range improves when walking across beams compared to into beams • Passive Dual Technology (Microphonics™) provides overlapping detection of human activity over the complete PIR coverage area; advanced filtering is utilized to prevent non-occupant noises from keeping the lights on

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SPECIFICATIONS PHYSICAL ENVIRONMENTAL SIZE: 4.5" Diameter (11.56 cm), 2.39" Deep (6.07 cm) OPERATING TEMP: WEIGHT: 6 oz CM xx WR: -4° to 122° (-20° to 50° C) CM PDT xx WR: 25° to 122°F (-4° to 50° C) MOUNTING: Ceiling Surface, 3.5" Octagon Box, Single RELATIVE HUMIDITY: Gang Handy Box Standard: 20 to 90% non-condensing COLOR: White BATTERY TYPE: AA Lithium (1.5V) EXPECTED BATTERY LIFE: ~10 years (at factory defaults)

ORDERING INFORMATION Specifications subject to change. Example: CM PDT 9 WR Series Detection Coverage Wireless Technology

CM Ceiling mount sensor (blank) Passive Infrared (PIR) 9 Small motion 360° WR RDT™ Wireless PDT Dual Tech (PIR/Microphonics™) 10 Large motion 360°

32 / www.acuitycontrols.com PRODUCT INFORMATION Wireless Switches WIRELESS PRODUCTS Overview Features The SPODMR WR is a stylish, easy to install, and simple to use • Miswire protection, reversible line & load connections WIRELESS wall switch for use with paired CM (PDT) xx WR occupancy • Neutral wire required-no current leakage to load sensors or other RDT™ Wireless relay modules, kinetic PRODUCTS • Adjustable time delays switches, or plug-load controllers. Once wired, a few button Switch & Load Controller pushes is all it takes to pair the switch to the desired sensors. • Auto-On or Manual-On modes • Simple push-button pairing • 2 Green LED status Indicators

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SPECIFICATIONS PHYSICAL ELECTRICAL ENVIRONMENTAL SIZE: 2.74" H x 1.68"W x 1.63"D MAXIMUM LOAD1 : OPERATING TEMP: (6.96 cm x 4.27 cm x 4.14 cm) 800 W @ 120 VAC/1200 W @ 277 VAC (-20° to 50° C) WEIGHT: 5 oz (Fluorescent/Incandescent) RELATIVE HUMIDITY: 20-75% non-condensing MOUNTING: Single gang switch box See data sheet for LED specs WIRELESS FREQUENCY: 902 MHz (RDT™) 1A @ 24 VAC/VDC ROHS COMPLIANT MINUMUM LOAD: None

MOTOR LOAD: 1/4HP PRODUCT SELECTION GUIDE LOAD FREQUENCY: 50/60 Hz WIRING DIAGRAM(S): See Figure # 1 on Page 82

Notes 1. Load specifications for fluorescent and incandescent lighting only See data sheet for LED specifications

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules.

ORDERING INFORMATION Specifications subject to change. Example: SPODMR WR WH Series Operating Mode Color Kit

SPODMR WR Wall switch (blank) Auto on WH White (blank) None SA Manual on IV Ivory K1 Includes CM 9 WR GY Gray K2 Includes CM 10 WR AL Light Almond K3 Includes CM PDT 9 WR BK Black K4 Includes CM PDT 10 WR

www.acuitycontrols.com / 33 PRODUCT INFORMATION Ceiling Mount Sensors

Overview Features (All) CEILING Ceiling mount sensors are offered in a multitude of • 30 sec to 30 min time delay configurations which address many applications. Lens options • Digital PIR detection - excellent RF immunity MOUNT include large motion extended range, small motion standard • Push-button programmable Sensors range and bi-directional for hallways. Available in low voltage and line voltage models, these sensors are capable of covering • Minimum On-Timer (LampMaximizer®) an entire private office or small room by themselves. Multiple • Convenient test mode low voltage sensors can also work together to supply the ideal solution for oddly shaped rooms or large open office areas. • Green LED status Indicator A line voltage sensor provides one relay for a single-level Features (Line voltage) CEILING MOUNT SENSORS CEILING MOUNT control, while the 2-pole version provides a second relay for • Self-contained relay(s) an additional level of control. For rooms with obstructions, these sensors are also offered with Dual Technology, which • No minimum load adds Microphonics™ detection to the Passive Infrared (PIR) • Miswire protection, reversible line & load connections detection.

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SPECIFICATIONS PHYSICAL ELECTRICAL - LOW VOLTAGE ELECTRICAL - LINE VOLTAGE ENVIRONMENTAL

SIZE: 4.55” diameter (11.56 cm) OPERATING VOLTAGE: LOAD RATING: OPERATING TEMP: 1.55” deep (3.94 cm) 12-24 VAC/VDC 800 W @ 120 VAC 14º to 160º F (-10º to 71º C) WEIGHT: 6 oz RECOMMENDED POWER PACK: 1200 W @ 277 VAC STORAGE TEMP: MOUNTING: PP20 1500 W @ 347 VAC -14º to 160º F (-26º to 71º C) 3.5” octagon box, CURRENT DRAW: MOTOR LOAD: 1/4 HP RELATIVE HUMIDITY: or single gang handy box Standard, 4 mA FREQUENCY: 50/60 Hz 20 to 90% non-condensing COLOR: Matte White w/ R option, 16 mA WIRING DIAGRAM(S): ROHS COMPLIANT WIRING DIAGRAM(S): See Figure # 9 & 10 on Page 84 See Figure # 8 on Page 84 PRODUCT SELECTION GUIDE SELECTION PRODUCT

OPTION INFORMATION

R ADC Automatic Dimming Control DZ D Low Voltage Relay Photocontrol Dual Zone Photocontrol Occupancy Controlled Dimming • Enables sensors to interface with other • Photocontrol within sensor maintains total • Provides more advanced control than P • Provides dimming output to control 0-10 systems (e.g. BMS, lighting panels) room light level by controlling levels of option VDC dimmable ballasts/drivers 0-10 VDC dimmable ballasts/drivers • Provides dry contact closure via a SPDT, • DUO operation: Determines necessary • Provides a second occupancy time-out 1 amp, 30 volt relay (resistive loads only) • Photocontrol also has full on/off control on/off combination of poles in inboard/ period that enables lights to go to a dim during periods of occupancy outboard applications setting before turning off P • Provides a second occupancy time-out • Percentage offset operation: Uses relative • Sinks <20mA; ~40 ballast/drivers Photocontrol period that enables lights to go a dim set-point for second pole in dual zone • Adjustable max/min dim setting • Auto set-point calibration setting before turning off applications

• On/off mode: Full on/off control of 347 lighting during periods of occupancy with LT 347 Voltage adequate daylight Low Temp/High Humidity • Allows sensor to be powered and switch • Sensor electronics are coated for corrosion • Inhibit mode: Prevents lights from turning 347 VAC resistance on if adequate daylight is available, but does not turn lights off • Operates down to -40° F/C (-4°F/-20°C for PDT) • 2-pole units operate in inhibit mode only

34 / www.acuitycontrols.com PRODUCT INFORMATION Ceiling Mount Sensors CEILING MOUNT SENSORS

COVERAGE PATTERN

0 m 0 ft 6 High Bay 360º Lens

• Best choice for 15 to 45 ft (4.57 to 13.72 m) mounting heights 4.6 15 • 15 to 20 ft (4.57 to 6.10 m) radial coverage overlaps area lit by a typical LOW VIEW HIGH VIEW high bay fixture 9.1 30 • Excellent detection of large motion 0 ft 0 m (e.g., walking) up to a 35 ft (10.76 m) mounting height 15 4.6 13.7 45 • Excellent detection of extra large motion 6 3 0 m 3 6 9.1 6 3 0 m 3 6 9.1 (e.g., forklifts) up to a 45 ft (13.72 m) 20 10 0 ft 10 20 30 20 10 0 ft 10 20 30 mounting height

9 Small Motion / Standard Range 360º Lens 3.7 12

• Best choice for small motion (e.g., hand SIDE VIEW TOP VIEW 1.8 6 movements) detection 0 ft 0 m • Viewing angle of 56º in a 360º conical 0 m 0 ft shaped pattern 9 2.7 1.8 6 • Provides 12 ft (3.66 m) radial coverage when 3.7 1.8 0 m 1.8 3.7 mounted to standard 9 ft (2.74 m) ceiling 12 6 0 ft 6 12

3.7 12 PRODUCT SELECTION GUIDE • 8 to 15 ft (2.44 to 4.57 m) mounting heights provide 10 to 20 ft (3.05 to 6.10 m) radial coverage

Large Motion / Extended Range 360º Lens 10 8.5 28

• Best choice for large motion SIDE VIEW TOP VIEW 4.3 14 (e.g., walking) detection 0 ft 0 m

• Viewing angle of 67º in a 360º conical 0 m 0 ft shaped pattern 9 2.7 • Provides 28 ft (8.53 m) radial 4.3 14 8.5 6.4 4.3 2.1 0 m 2.1 4.3 6.4 8.5 coverage when mounted to standard 9 ft (2.74 m) ceiling 28 21 14 7 0 ft 7 14 21 28 8.5 28 • 7 to 15 ft (2.13 to 4.57 m) mounting heights provide 16 to 36 ft (4.88 to 10.97 m) radial coverage

11 Bi-Directional Hallway Lens 8.5 28

• Best choice for large motion SIDE VIEW TOP VIEW 4.3 14 (e.g., walking) detection 0 ft 0 m • Viewing angle of 67º for hallway 0 m 0 ft applications 9 2.7 4.3 14 • Provides 28 ft (8.53 m) of coverage when 8.5 6.4 4.3 2.1 0 m 2.1 4.3 6.4 8.5 mounted to standard 9 ft (2.74 m) ceiling 28 21 14 7 0 ft 7 14 21 28 8.5 28 • 7 to 15 ft (2.13 to 4.57 m) mounting heights provide 16 to 36 ft (4.88 to 10.97 m) hallway coverage

www.acuitycontrols.com / 35 PRODUCT INFORMATION Ceiling Mount Sensors

KEY SPECS SERIES COVERAGE PATTERN DETECTION POWER TYPE CM 6 High Bay 360° Lens PIR Low 12-24 CM 9 Small Motion/Standard Range 360° 9 Lens PIR Low 12-24 CM PDT 9 Small Motion/Standard Range 360° 9 Lens Dual technology (PDT) Low 12-24 CM 10 Large Motion/Extended Range 360° 10 Lens PIR Low 12-24 CM PDT 10 Large Motion/Extended Range 360° 10 Lens Dual technology (PDT) Low 12-24

CEILING MOUNT SENSORS CEILING MOUNT CM 11 Bi-Directional Hallway Lens PIR Low 12-24 CM PDT 11 Bi-Directional Hallway Lens Dual technology (PDT) Low 12-24 CMR 6 High Bay 360° Lens PIR Line 120/277 CMR 9 Small Motion/Standard Range 360° 9 Lens PIR Line 120/277 CMR PDT 9 Small Motion/Standard Range 360° 9 Lens Dual technology (PDT) Line 120/277 CMR 10 Large Motion/Extended Range 360° 10 Lens PIR Line 120/277 CMR PDT 10 Large Motion/Extended Range 360° 10 Lens Dual technology (PDT) Line 120/277 CMR 6 2P High Bay 360° Lens PIR Line 120/277 CMR 9 2P Small Motion/Standard Range 360° 9 Lens PIR Line 120/277 CMR PDT 9 2P Small Motion/Standard Range 360° 9 Lens Dual technology (PDT) Line 120/277 CMR 10 2P Large Motion/Extended Range 360° 10 Lens PIR Line 120/277 CMR PDT 10 2P Large Motion/Extended Range 360° 10 Lens Dual technology (PDT) Line 120/277

LOW VOLTAGE Specifications subject to change. Example: CM 9 R P LT Series Relay Dimming/Photocontrol Choose One Only Temp/Humidity

CM 6 (blank) None (blank) None (blank) Standard CM 9 R Low Voltage Relay D Occupancy Controlled High/Low Dimming LT Low Temp/High Humidity CM PDT 9 P Photocontrol CM 10 ADC Photocontrol with Dimming CM PDT 10 CM 11 CM PDT 11 PRODUCT SELECTION GUIDE SELECTION PRODUCT

LINE VOLTAGE Specifications subject to change. Example: CMR 9 P 347 LT Series Dimming/Photocontrol Choose One Only Voltage Temp/Humidity

CMR 6 (blank) None (blank) 120/277 VAC (blank) Standard CMR 9 D Occupancy Controlled High/Low Dimming 347 347 VAC LT Low Temp/High Humidity CMR PDT 9 P Photocontrol CMR 10 ADC Photocontrol with Dimming CMR PDT 10

2-POLE, LINE VOLTAGE Specifications subject to change. Example: CMR 9 2P DZ LT Series Dimming/Photocontrol Choose One Only Voltage Temp/Humidity

CMR 6 2P (blank) None (blank) 120/277 VAC (blank) Standard CMR 9 2P P Photocontrol (inhibit only) 347 347 VAC LT Low Temp/High Humidity CMR PDT 9 2P DZ Dual Zone Photocontrol CMR 10 2P CMR PDT 10 2P

36 / www.acuitycontrols.com

PRODUCT INFORMATION Ceiling Mount Daylight Controls

Overview Features CEILING On/off Photocontrol and dimming sensors provide intelligent • Works as stand-alone unit or with occupancy sensors control of lighting for indoor daylight applications. Ideal • Auto set-point calibration MOUNT for spaces with windows, such as vestibules, corridors, classrooms or offices, the sensors work by monitoring daylight • Push-button programmable DAYLIGHT conditions in a room, then controlling the lighting to ensure • 100 hr. lamp burn-in timer that adequate lighting levels are maintained. • Fully digital control CONTROLS Low voltage sensors are powered with 12-24 VAC/VDC. • Green LED status Indicator On/off Photocontrol sensors operate with a power pack Switching & Dimming Sensors (Model # PP20), enabling complete 20 Amp circuits to be controlled. Dimming Photocontrol sensors are capable of controlling any 0-10 VDC dimmable ballast or driver. Line CEILING MOUNT DAYLIGHT CONTROLS DAYLIGHT CEILING MOUNT voltage versions are also available that integrate a line switching relay and/or power off the line.

SOLUTION TYPES / KEY LIGHTS/ KEYFULL ON LIGHTSLIGHTS/ KEY FULL OFF ON LIGHTSLIGHTSLIGHTS FULL FULL OFF DIM ON LIGHTSLIGHTS FULL OFF DIM LIGHTS FULL DIM

PC ADC PC ADC Automatic On/Off Switching Automatic Dimming Control Combination On/Off & Dimming Control

PC PC ADCPC ADC PCADC ADC PC ADC PC ADC AMPLE DAYLIGHT AMPLE DAYLIGHTAMPLEAMPLE DAYLIGHT DAYLIGHT AMPLE DAYLIGHT AMPLEAMPLE DAYLIGHT DAYLIGHT AMPLE DAYLIGHT AMPLE DAYLIGHT DEADBAND DEADBAND DEADBAND DIMMING DIMMING DIMMING DIMMING DIMMING DIMMING RANGE RANGE RANGE RANGE RANGE RANGE

SET-POINT SET-POINT SET-POINTSET-POINT SET-POINT SET-POINTSET-POINT SET-POINT SET-POINT PRODUCT SELECTION GUIDE SELECTION PRODUCT NO DAYLIGHT NO DAYLIGHT NO NODAYLIGHT DAYLIGHT NO DAYLIGHT NONO DAYLIGHT DAYLIGHT NO DAYLIGHT NO DAYLIGHT

/ KEY LIGHTS FULL ON LIGHTS OFF LIGHTS FULL DIM

PC ADC PC ADC

SPECIFICATIONSAMPLE DAYLIGHT AMPLE DAYLIGHT AMPLE DAYLIGHT PHYSICAL ELECTRICAL - LOW VOLTAGE ELECTRICAL - LINE VOLTAGE ENVIRONMENTAL DEADBAND DIMMING DIMMING

SIZE: 4.55” diameter (11.56 cm) OPERATING VOLTAGE: LOAD RATING: RANGE OPERATING TEMP: RANGE 1.55” deep (3.94 cm) 12-24 VAC/VDC 800 W @ 120 VAC 14º to 160º F (-10º to 71º C) WEIGHT: 6 oz RECOMMENDED POWER PACK: 1200 W @ 277 VAC STORAGE TEMP: MOUNTING: PP20 1500 W @ SET-POINT347 VAC -14º SET-POINTto 160º F (-26º to 71º C) SET-POINT 3.5” octagon box, CURRENT DRAW: MOTOR LOAD: 1/4 HP RELATIVE HUMIDITY: or single gang handy box Standard, 4 mA DIMMING LOAD: 20 to 90% non-condensing COLOR: White DIMMING LOAD: Sinks up to 20 mA or 40 ballasts/ ROHS COMPLIANT Sinks up to 20 mA or 40 ballasts/ driversNO DAYLIGHT @ .5 mA each (0-10 VDC NO DAYLIGHT NO DAYLIGHT drivers @ .5 mA each (0-10 VDC dimmable balasts/drivers only) dimmable balasts/drivers only) WIRING DIAGRAM(S): WIRING DIAGRAM(S): See Figure # 22 - 28 on Page 88 - 89 See Figure # 22 - 28 on Page 88 - 89

38 / www.acuitycontrols.com CEILING MOUNT DAYLIGHT CONTROLS PRODUCT INFORMATION Ceiling Mount Daylight Controls

OPTION INFORMATION

DZ 347 LT Dual Zone 347 VAC Low Temp/High Humidity • Provide second output that can control an additional • Allows sensor to be powered from and switch 347 VAC • Sensor electronics are coated for corrosion resistance zone of lighting • Operates down to -40°F/C Stepped Dimming (Duo) Operation (PC Only) • Ideal for A/B (also called inboard/outboard) switching applications • Determines the necessary on/off combination of the two poles in order to maintain adequate lighting Percentage Offset Operation • Ideal for classrooms with individually controlled parallel rows of lights • PC sensors use a relative set-point for the second pole that is a percentage of the first pole’s set-point • ADC sensors enable control of an additional 0-10 VDC dimmable ballast or driver at a selected level (voltage) higher than that of the primary zone

KEY SPECS SERIES ENCLOSURE CONTROL TYPE POWER TYPE [VDC/VAC] CM PC Ceiling mount On/off Low 12-24 CM ADC Ceiling mount Dimming Low 12-24 PRODUCT SELECTION GUIDE CM PC ADC Ceiling mount On/off & dimming Low 12-24 CMR PC Ceiling mount On/off Line 120/277 CMR ADC Ceiling mount Dimming Line 120/277 CMR PC ADC Ceiling mount On/off & dimming Line 120/277

LOW VOLTAGE Example: CM PC DZ LT Series Dual Zone Temp/Humidity

CM PC (blank) Single Zone (blank) Standard CM ADC DZ Dual Zone LT Low Temp/High Humidity CM PC ADC

LINE VOLTAGE Example: CMR PC DZ LT Series Dual Zone Voltage1 Temp/Humidity

CMR PC (blank) None (blank) 120/277 VAC (blank) Standard CMR ADC DZ Dual zone 2 208 208/240 VAC 2 LT Low Temp/High Humidity CMR PC ADC 347 347 VAC 480 480 VAC 2 Notes 1. 480 and 208 option not available w/dual zone (DZ) 2. CMR PC Only

www.acuitycontrols.com / 39 PRODUCT INFORMATION Recessed Mount Sensors

Overview Features (All) RECESSED Recessed mount sensors offer the reliable functionality of • 30 sec to 30 min time delay the standard ceiling mount with an architectural aesthetic. • Digital PIR detection - excellent RF immunity MOUNT Recessed mount sensors are designed to fit inside a standard • Push-button programmable Sensors junction box making installation quick and easy. Lens options include large motion extended range and small motion • Minimum On-Timer (LampMaximizer®) standard range. Available in low voltage and line voltage • Convenient test mode models, these sensors are capable of covering an entire private office or small room by themselves. Multiple low • Green LED Status Indicator voltage sensors can also work together to supply the ideal Features (Line voltage)

RECESSED MOUNT SENSORS RECESSED MOUNT solution for oddly shaped rooms or large open office areas. • Miswire protection, reversible line & load connections A line voltage sensor provides one relay for a single-level control, while the 2-pole version provides a second relay for • Self-contained relay(s) an additional level of control. For rooms with obstructions, • No minimum load these sensors are also offered with Dual Technology, which adds Microphonics™ detection to the Passive Infrared (PIR) detection.

COVERAGE PATTERN

Small Motion / Standard Range 360º Lens 9 3.7 12

• Best choice for small motion (e.g., hand SIDE VIEW TOP VIEW 1.8 6 movements) detection 0 ft 0 m • Viewing angle of 56º in a 360º conical 0 m 0 ft shaped pattern 9 2.7 • Provides 12 ft (3.66 m) radial coverage when 1.8 6 3.7 1.8 0 m 1.8 3.7 mounted to standard 9 ft (2.74 m) ceiling 12 6 0 ft 6 12 3.7 12 • 8 to 15 ft (2.44 to 4.57 m) mounting heights provide 10 to 20 ft (3.05 to 6.10 m) radial coverage • Passive Dual Technology (Microphonics™) provides overlapping detection of human activity over the complete PIR coverage area; advanced filtering is utilized to prevent non-occupant noises from keeping the lights on

10 Large Motion / Extended Range 360º Lens 8.5 28 • Best choice for large motion SIDE VIEW TOP VIEW 4.3 14 (e.g., walking) detection 0 ft 0 m PRODUCT SELECTION GUIDE SELECTION PRODUCT • Viewing angle of 67º in a 360º conical 0 m 0 ft shaped pattern 9 2.7 • Provides 28 ft (8.53 m) radial 4.3 14 8.5 6.4 4.3 2.1 0 m 2.1 4.3 6.4 8.5 coverage when mounted to standard 9 ft (2.74 m) ceiling 28 21 14 7 0 ft 7 14 21 28 8.5 28 • 7 to 15 ft (2.13 to 4.57 m) mounting heights provide 16 to 36 ft (4.88 to 10.97 m) radial coverage • Passive Dual Technology (Microphonics™) provides overlapping detection of human activity over the complete PIR coverage area; advanced filtering is utilized to prevent non-occupant noises from keeping the lights on

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SPECIFICATIONS PHYSICAL ELECTRICAL - LOW VOLTAGE ELECTRICAL - LINE VOLTAGE ENVIRONMENTAL

SIZE: 4.40” square (11.18 cm) OPERATING VOLTAGE: LOAD RATING: OPERATING TEMP: WEIGHT: 6 oz 12-24 VAC/VDC 800 W @ 120 VAC 14º to 160º F (-10º to 71º C) MOUNTING: RECOMMENDED POWER PACK: 1200 W @ 277 VAC STORAGE TEMP: 4 x 4 square junction box with PP20 1500 W @ 347 VAC -14º to 160º F (-26º to 71º C) or without two-gang mudring; directly to ceiling tile through CURRENT DRAW: MOTOR LOAD: 1/4 HP RELATIVE HUMIDITY: 2.65 (6.7 cm) square opening Standard, 4 mA FREQUENCY: 50/60 Hz 20 to 90% non-condensing COLOR: White w/ R option, 16 mA WIRING DIAGRAM(S): ROHS COMPLIANT WIRING DIAGRAM(S): See Figure # 9 & 10 on Page 84 See Figure # 8 on Page 84

40 / www.acuitycontrols.com PRODUCT INFORMATION Recessed Mount Sensors RECESSED MOUNT SENSORS

KEY SPECS SERIES COVERAGE PATTERN DETECTION POWER TYPE RM 9 Small Motion/Standard Range 360° 9 Lens PIR Low 12-24 RM PDT 9 Small Motion/Standard Range 360° 9 Lens Dual technology (PDT) Low 12-24 RM 10 Large Motion/Extended Range 360° 10 Lens PIR Low 12-24 RM PDT 10 Large Motion/Extended Range 360° 10 Lens Dual technology (PDT) Low 12-24 RMR 9 Small Motion/Standard Range 360° 9 Lens PIR Line 120/277 RMR PDT 9 Small Motion/Standard Range 360° 9 Lens Dual technology (PDT) Line 120/277 RMR 10 Large Motion/Extended Range 360° 10 Lens PIR Line 120/277 RMR PDT 10 Large Motion/Extended Range 360° 10 Lens Dual technology (PDT) Line 120/277 RMR 9 2P Small Motion/Standard Range 360° 9 Lens PIR Line 120/277 RMR PDT 9 2P Small Motion/Standard Range 360° 9 Lens Dual technology (PDT) Line 120/277 RMR 10 2P Large Motion/Extended Range 360° 10 Lens PIR Line 120/277 RMR PDT 10 2P Large Motion/Extended Range 360° 10 Lens Dual technology (PDT) Line 120/277

OPTION INFORMATION

R ADC Automatic Dimming Control DZ D Low Voltage Relay Photocontrol Dual Zone Photocontrol Occupancy Controlled Dimming • Enables sensors to interface with other • Photocontrol within sensor maintains total • Provides more advanced control than P • Provides dimming output to control 0-10 systems (e.g. BMS, lighting panels) room light level by controlling levels of option VDC dimmable ballasts/drivers 0-10 VDC dimmable ballasts/drivers • Provides dry contact closure via a SPDT, • DUO operation: Determines necessary • Provides a second occupancy time-out 1 amp, 30 volt relay (resistive loads only) • Photocontrol also has full on/off control on/off combination of poles in inboard/ period that enables lights to go to a dim during periods of occupancy outboard applications setting before turning off PRODUCT SELECTION GUIDE P • Provides a second occupancy time-out • Percentage offset operation: Uses relative • Sinks <20mA; ~40 ballast/drivers Photocontrol period that enables lights to go a dim set-point for second pole in dual zone • Adjustable max/min dim setting • Auto set-point calibration setting before turning off applications

• On/off mode: Full on/off control of 347 lighting during periods of occupancy with LT 347 Voltage adequate daylight Low Temp/High Humidity • Allows sensor to be powered and switch • Sensor electronics are coated for corrosion • Inhibit mode: Prevents lights from turning 347 VAC resistance on if adequate daylight is available, but does not turn lights off • Operates down to -40° F/C (-4°F/-20°C for PDT) • 2-pole units operate in inhibit mode only

LOW VOLTAGE Specifications subject to change. Example: RM 9 R P LT Series Relay Dimming/Photocontrol Choose One Only Temp/Humidity

RM 9 (blank) None (blank) None (blank) Standard RM PDT 9 R Low Voltage Relay D Occupancy Controlled High/Low Dimming LT Low Temp/High Humidity RM 10 P Photocontrol RM PDT 10 ADC Photocontrol with Dimming

LINE VOLTAGE Specifications subject to change. Example: RMR 9 P 347 LT Series Dimming/Photocontrol Choose One Only Voltage Temp/Humidity

RMR 9 (blank) None (blank) 120/277 VAC (blank) Standard RMR PDT 9 D Occupancy Controlled High/Low Dimming 347 347 VAC LT Low Temp/High Humidity RMR 10 P Photocontrol RMR PDT 10 ADC Photocontrol with Dimming

2-POLE, LINE VOLTAGE Specifications subject to change. Example: RMR 9 2P DZ LT Series Dimming/Photocontrol Choose One Only Voltage Temp/Humidity

RMR 9 2P (blank) None (blank) 120/277 VAC (blank) Standard RMR PDT 9 2P P Photocontrol (inhibit only) 347 347 VAC LT Low Temp/High Humidity RMR 10 2P DZ Dual Zone Photocontrol RMR PDT 10 2P

www.acuitycontrols.com / 41 PRODUCT INFORMATION Recessed Mount Daylight Controls

Overview Features RECESSED On/off Photocontrol and dimming sensors provide intelligent • Works as stand-alone unit or with occupancy sensors control of lighting for indoor daylight applications. Ideal • Auto set-point calibration MOUNT for spaces with windows, such as vestibules, corridors, classrooms or offices, the sensors work by monitoring daylight • Push-button programmable DAYLIGHT conditions in a room, then controlling the lighting to ensure • 100 hr. lamp burn-in timer that adequate lighting levels are maintained. • Fully digital control CONTROLS Low voltage sensors are powered with 12-24 VAC/VDC. • Green LED status Indicator On/off Photocontrol sensors operate with a power pack Switching & Dimming Sensors (Model # PP20), enabling complete 20 Amp circuits to be controlled. Dimming Photocontrol sensors are capable of controlling any 0-10 VDC dimmable ballast or driver. Line

RECESSED MOUNT DAYLIGHT CONTROLS DAYLIGHT RECESSED MOUNT voltage versions are also available that integrate a line switching relay and/or power off the line.

SOLUTION TYPES / KEY LIGHTS/ KEYFULL ON LIGHTSLIGHTS/ KEY FULL OFF ON LIGHTSLIGHTSLIGHTS FULL FULL OFF DIM ON LIGHTSLIGHTS FULL OFF DIM LIGHTS FULL DIM

PC ADC PC ADC Automatic On/Off Switching Automatic Dimming Control Combination On/Off & Dimming Control

PC PC ADCPC ADC PCADC ADC PC ADC PC ADC AMPLE DAYLIGHT AMPLE DAYLIGHTAMPLEAMPLE DAYLIGHT DAYLIGHT AMPLE DAYLIGHT AMPLEAMPLE DAYLIGHT DAYLIGHT AMPLE DAYLIGHT AMPLE DAYLIGHT DEADBAND DEADBAND DEADBAND DIMMING DIMMING DIMMING DIMMING DIMMING DIMMING RANGE RANGE RANGE RANGE RANGE RANGE

SET-POINT SET-POINT SET-POINTSET-POINT SET-POINT SET-POINTSET-POINT SET-POINT SET-POINT PRODUCT SELECTION GUIDE SELECTION PRODUCT NO DAYLIGHT NO DAYLIGHT NO NODAYLIGHT DAYLIGHT NO DAYLIGHT NONO DAYLIGHT DAYLIGHT NO DAYLIGHT NO DAYLIGHT

/ KEY LIGHTS FULL ON LIGHTS OFF LIGHTS FULL DIM

PC ADC PC ADC

SPECIFICATIONSAMPLE DAYLIGHT AMPLE DAYLIGHT AMPLE DAYLIGHT PHYSICAL ELECTRICAL - LOW VOLTAGE ELECTRICAL - LINE VOLTAGE ENVIRONMENTAL DEADBAND DIMMING DIMMING

SIZE: 4.40” square (11.18 cm) OPERATING VOLTAGE: LOAD RATING: RANGE OPERATING TEMP: RANGE WEIGHT: 6 oz 12-24 VAC/VDC 800 W @ 120 VAC 14º to 160º F (-10º to 71º C) MOUNTING:  RECOMMENDED POWER PACK: 1200 W @ 277 VAC STORAGE TEMP: 4 x 4 square junction box with PP20 1500 W @ SET-POINT347 VAC -14º SET-POINTto 160º F (-26º to 71º C) SET-POINT or without two-gang mudring; CURRENT DRAW: MOTOR LOAD: 1/4 HP RELATIVE HUMIDITY: directly to ceiling tile through 2.65 (6.7 cm) square opening Standard, 4 mA DIMMING LOAD: 20 to 90% non-condensing COLOR: White DIMMING LOAD: Sinks up to 20 mA or 40 ballasts/ ROHS COMPLIANT Sinks up to 20 mA or 40 ballasts/ driversNO DAYLIGHT @ .5 mA each (0-10 VDC NO DAYLIGHT NO DAYLIGHT drivers @ .5 mA each (0-10 VDC dimmable balasts/drivers only) dimmable balasts/drivers only) WIRING DIAGRAM(S): WIRING DIAGRAM(S): See Figure # 22 - 28 on Page 88 - 89 See Figure # 22 - 28 on Page 88 - 89

42 / www.acuitycontrols.com RECESSED MOUNT DAYLIGHT CONTROLS

PRODUCT INFORMATION Recessed Mount Daylight Controls

KEY SPECS SERIES ENCLOSURE CONTROL TYPE POWER TYPE [VDC/VAC] RM PC Recessed mount On/off Low 12-24 RM ADC Recessed mount Dimming Low 12-24 RM PC ADC Recessed mount On/off & dimming Low 12-24 RMR PC Recessed mount On/off Line 120/277 RMR ADC Recessed mount Dimming Line 120/277 RMR PC ADC Recessed mount On/off & dimming Line 120/277

OPTION INFORMATION

DZ 347 LT Dual Zone 347 VAC Low Temp/High Humidity • Provides second output that can control an additional • Allows sensor to be powered from and switch 347 VAC • Sensor electronics are coated for corrosion resistance zone of lighting • Operates down to -40°F/C Stepped Dimming (Duo) Operation (PC Only) • Ideal for A/B (also called inboard/outboard) switching

applications PRODUCT SELECTION GUIDE • Determines the necessary on/off combination of the two poles in order to maintain adequate lighting Percentage Offset Operation • Ideal for classrooms with individually controlled parallel rows of lights • PC sensors use a relative set-point for the second pole that is a percentage of the first pole’s set-point • ADC sensors enable control of an additional 0-10 VDC dimmable ballast or driver at a selected level (voltage) higher than that of the primary zone

LOW VOLTAGE Example: RM PC DZ LT Series Dual Zone Temp/Humidity

RM PC (blank) Single Zone (blank) Standard RM ADC DZ Dual Zone LT Low Temp/High Humidity RM PC ADC

LINE VOLTAGE Example: RMR PC DZ LT Series Dual Zone Voltage Temp/Humidity

RMR PC (blank) None (blank) 120/277 VAC (blank) Standard RMR ADC DZ Dual zone 1 347 347 VAC LT Low Temp/High Humidity RMR PC ADC

Notes 1. RMR PC Only

www.acuitycontrols.com / 43 PRODUCT INFORMATION Fixture Mount Sensors

Overview Features (All) FIXTURE Fixture mount sensors provide passive infrared occupancy • 30 sec to 30 min time delay detection that overlap the areas lit by a luminaire. Fixture • Digital PIR detection - excellent RF immunity MOUNT mount sensors are designed to mount directly to the end of a • Push-button programmable Sensors light fixture through an extended ½ inch chase nipple. Lens options include large motion extended range, small motion • Minimum On-Timer (LampMaximizer®) standard range, bi-directional for hallways and high bay. Low • Convenient test mode voltage sensors are used in conjunction with power packs, which contain a relay, and are ideal when multiple sensors are • Green LED status Indicator needed. Line voltage versions have an integrated relay making Features (Line voltage) FIXTURE MOUNT SENSORS FIXTURE MOUNT it an effective solution when controlling an entire circuit with a • Miswire protection, reversible line & load connections single sensor. Furthermore 2P (two pole) line voltage versions provide a second relay for an additional level of control. • Self-contained relay(s) Options including PDT (Passive Dual Technology), integrated • No minimum load photocell, dimming control, low temp/humidity and 347 voltage are also available.

6 High Bay 360°

AVAILABLE LENSES

50 High Bay 10 Large Motion / HMB 10 9 Small Motion / Bi-Directional Aisleway Extended Range 360º High Bay End-of-Aisle Standard Range 360º

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SPECIFICATIONS PHYSICAL ELECTRICAL - LOW VOLTAGE ELECTRICAL - LINE VOLTAGE ENVIRONMENTAL

SIZE: 3.63” H x 3.63” W x 1.50” D OPERATING VOLTAGE: LOAD RATING: OPERATING TEMP: (9.22 cm x 9.22 cm x 3.81 cm) 12-24 VAC/VDC 800 W @ 120 VAC 14º to 160º F (-10º to 71º C) WEIGHT: 6 oz RECOMMENDED POWER PACK: 1000 W @ 208 VAC STORAGE TEMP: MOUNTING: .5” knockout PP20 1200 W @ 277 VAC

PRODUCT SELECTION GUIDE SELECTION PRODUCT -14º to 160º F (-26º to 71º C) COLOR: White CURRENT DRAW: 1500 W @ 347 VAC RELATIVE HUMIDITY: Standard, 4 mA 2160 W @ 480 VAC 20 to 90% non-condensing w/ R option, 16 mA MOTOR LOAD: 1/4 HP ROHS COMPLIANT WIRING DIAGRAM(S): FREQUENCY: 50/60 Hz See Figure # 11 on Page 85 WIRING DIAGRAM(S): See Figure # 12, 13 on Page 85

OPTION INFORMATION

R ADC Automatic Dimming Control DZ D Low Voltage Relay Photocontrol Dual Zone Photocontrol Occupancy Controlled Dimming • Enables sensors to interface with other • Photocontrol within sensor maintains total • Provides more advanced control than P • Provides dimming output to control 0-10 systems (e.g. BMS, lighting panels) room light level by controlling levels of option VDC dimmable ballasts/drivers 0-10 VDC dimmable ballasts/drivers • Provides dry contact closure via a SPDT, • DUO operation: Determines necessary • Provides a second occupancy time-out 1 amp, 30 volt relay (resistive loads only) • Photocontrol also has full on/off control on/off combination of poles in inboard/ period that enables lights to go to a dim during periods of occupancy outboard applications setting before turning off P • Provides a second occupancy time-out • Percentage offset operation: Uses relative • Sinks <20mA; ~40 ballast/drivers Photocontrol period that enables lights to go a dim set-point for second pole in dual zone • Adjustable max/min dim setting • Auto set-point calibration setting before turning off applications

• On/off mode: Full on/off control of 347 lighting during periods of occupancy with LT 347 Voltage adequate daylight Low Temp/High Humidity • Allows sensor to be powered and switch • Sensor electronics are coated for corrosion • Inhibit mode: Prevents lights from turning 347 VAC resistance on if adequate daylight is available, but does not turn lights off • Operates down to -40° F/C (-4°F/-20°C for PDT) • 2-pole units operate in inhibit mode only

44 / www.acuitycontrols.com PRODUCT INFORMATION Fixture Mount Sensors FIXTURE MOUNT SENSORS

COVERAGE PATTERN

0 m 0 ft 6 High Bay 360º Lens

• Best choice for 15 to 45 ft (4.57 to 13.72 m) mounting heights 4.6 15 • 15 to 20 ft (4.57 to 6.10 m) radial coverage overlaps area lit by a typical LOW VIEW HIGH VIEW high bay fixture 9.1 30 • Excellent detection of large motion 0 ft 0 m (e.g., walking) up to a 35 ft (10.76 m) mounting height 15 4.6 13.7 45 • Excellent detection of extra large motion 6 3 0 m 3 6 9.1 6 3 0 m 3 6 9.1 (e.g., forklifts) up to a 45 ft (13.72 m) 20 10 0 ft 10 20 30 20 10 0 ft 10 20 30 mounting height

50 High Bay Bi-Directional Aisleway Lens

• Provides 50º bi-directional and 10º SIDE VIEW 0 ft 0 m wide coverage pattern 10 3 • 1.2x mounting height equals TOP VIEW approximate detection range in either 20 6 7 2.1 direction 30 9.1 0 ft 0 m • Typical 40 ft (12.19 m) mounting 40 12.2 7 2.1 detects 50 ft (15.24 m) in either 15.2 7.6 0 m 7.6 15.2 15.2 7.6 0 m 7.6 15.2 direction 50 25 0 ft 25 50 50 25 0 ft 25 50 PRODUCT SELECTION GUIDE

Large Motion / Extended Range 360º Lens 10 8.5 28

• Best choice for large motion SIDE VIEW TOP VIEW 4.3 14 (e.g., walking) detection 0 ft 0 m

• Viewing angle of 67º in a 360º conical 0 m 0 ft shaped pattern 9 2.7 • Provides 28 ft (8.53 m) radial 4.3 14 8.5 6.4 4.3 2.1 0 m 2.1 4.3 6.4 8.5 coverage when mounted to standard 9 ft (2.74 m) ceiling 28 21 14 7 0 ft 7 14 21 28 8.5 28 • 7 to 15 ft (2.13 to 4.57 m) mounting heights provide 16 to 36 ft (4.88 to 10.97 m) radial coverage

HMB 10 High Bay End-of-Aisle SIDE VIEW TOP VIEW • Detects motion from the end of an aisle 0 ft 0 m 10 3

up to 110 ft (33.53 m) long 5 1.5 10 3 • Designed to mount 30 ft (9.14 m) high 0 ft 0 m and 10 ft (3.05 m) back from end-of-aisle 20 6 5 1.5 • Sensors should always be applied in pairs facing each other from either end 30 9.1 10 3 of an aisle 0 m 3 15.2 27.4 36.6 0 m 3 15.2 27.4 36.6 0 ft 10 50 90 120 0 ft 10 50 90 120

9 Small Motion / Standard Range 360º Lens 3.7 12

• Best choice for small motion (e.g., hand SIDE VIEW TOP VIEW 1.8 6 movements) detection 0 ft 0 m • Viewing angle of 56º in a 360º conical 0 m 0 ft shaped pattern 9 2.7 1.8 6 • Provides 12 ft (3.66 m) radial coverage when 3.7 1.8 0 m 1.8 3.7 mounted to standard 9 ft (2.74 m) ceiling 12 6 0 ft 6 12 3.7 12 • 8 to 15 ft (2.44 to 4.57 m) mounting heights provide 10 to 20 ft (3.05 to 6.10 m) radial coverage

www.acuitycontrols.com / 45 PRODUCT INFORMATION Fixture Mount Sensors

LOW VOLTAGE Specifications subject to change. Example: CMB 9 R P LT Series Relay Dimming/Photocontrol Choose One Only Temp/Humidity

CMB 9 (blank) None (blank) None (blank) Standard CMB PDT 9 R Low Voltage Relay D Occupancy Controlled High/Low Dimming LT Low Temp/High Humidity CMB 10 P Photocontrol CMB PDT 10 ADC Photocontrol with Dimming FIXTURE MOUNT SENSORS FIXTURE MOUNT

LOW VOLTAGE Specifications subject to change. Example: CMB 6 R P LT Series Relay Dimming1 Photocontrol2 Temp/Humidity

CMB 6 (blank) None (blank) None (blank) None (blank) Standard CMB 50 R Low voltage relay D Occupancy controlled high/low dimming P Photocontrol LT Low Temp/High Humidity HMB 10

Notes 1. CMB 6 only 2. Not available for HMB 10

LINE VOLTAGE Specifications subject to change. Example: CMRB 6 LT Series Photocontrol/Dimming (choose one only) Voltage3 Temp/Humidity

CMRB 6 (blank) None (blank) 120/277 VAC (blank) Standard CMRB 6 208 D Occupancy controlled high/low dimming1 347 347 VAC LT Low Temp/High Humidity CMRB 6 480 P Switching Photocontrol 1, 2 CMRB 50 ADC Photocontrol with Dimming 2 CMRB 50 208 CMRB 50 480 HMRB 10 HMRB 10 208 HMRB 10 480

Notes 1. Only available for CMRB 6 series 2. Not available on HMRB 10 XX series 3. Not available with "208 or "480" series PRODUCT SELECTION GUIDE SELECTION PRODUCT LINE VOLTAGE Specifications subject to change. Example: CMRB 9 P 347 LT Series Dimming/Photocontrol Choose One Only Voltage Temp/Humidity

CMRB 9 (blank) None (blank) 120/277 VAC (blank) Standard CMRB PDT 9 D Occupancy Controlled High/Low Dimming 347 347 VAC LT Low Temp/High Humidity CMRB 10 P Photocontrol CMRB PDT 10 ADC Photocontrol with Dimming

2-POLE, LINE VOLTAGE Specifications subject to change. Example: CMRB 6 2P P LT Series Photocontrol1 Voltage Temp/Humidity

CMRB 6 2P (blank) None (blank) 120/277 VAC (blank) Standard CMRB 50 2P P Photocontrol 3471 347 VAC LT Low Temp/High Humidity HMRB 10 2P Notes 1. Not available with HMRB 10 2P series

2-POLE, LINE VOLTAGE Specifications subject to change. Example: CMRB 9 2P DZ LT Series Dimming/Photocontrol Choose One Only Voltage Temp/Humidity

CMRB 9 2P (blank) None (blank) 120/277 VAC (blank) Standard CMRB PDT 9 2P P Photocontrol (inhibit only) 347 347 VAC LT Low Temp/High Humidity CMRB 10 2P DZ Dual Zone Photocontrol CMRB PDT 10 2P

46 / www.acuitycontrols.com

PRODUCT INFORMATION Fixture Mount Daylight Controls

Overview Features FIXTURE On/off Photocontrol and dimming sensors provide intelligent • Works as stand-alone unit or with occupancy sensors control of lighting for indoor daylight applications. Ideal • Auto set-point calibration MOUNT for spaces with windows, such as vestibules, corridors, classrooms or offices. The sensors work by monitoring daylight • Push-button programmable DAYLIGHT conditions in a room, then controlling the lighting to ensure • 100 hr. lamp burn-in timer that adequate lighting levels are maintained. • Fully digital control CONTROLS Low voltage sensors are powered with 12-24 VAC/VDC. • Green LED status Indicator On/off Photocontrol sensors operate with a power pack Switching & Dimming Sensors (Model # PP20), enabling complete 20 Amp circuits to be controlled. Dimming Photocontrol sensors are capable of controlling any 0-10 VDC dimmable ballast or driver. Line FIXTURE MOUNT DAYLIGHT CONTROLS DAYLIGHT FIXTURE MOUNT voltage versions are also available that integrate a line switching relay and/or power off the line.

SOLUTION TYPES / KEY LIGHTS/ KEYFULL ON LIGHTSLIGHTS/ KEY FULL OFF ON LIGHTSLIGHTSLIGHTS FULL FULL OFF DIM ON LIGHTSLIGHTS FULL OFF DIM LIGHTS FULL DIM

PC ADC PC ADC Automatic On/Off Switching Automatic Dimming Control Combination On/Off & Dimming Control

PC PC ADCPC ADC PCADC ADC PC ADC PC ADC AMPLE DAYLIGHT AMPLE DAYLIGHTAMPLEAMPLE DAYLIGHT DAYLIGHT AMPLE DAYLIGHT AMPLEAMPLE DAYLIGHT DAYLIGHT AMPLE DAYLIGHT AMPLE DAYLIGHT DEADBAND DEADBAND DEADBAND DIMMING DIMMING DIMMING DIMMING DIMMING DIMMING RANGE RANGE RANGE RANGE RANGE RANGE

SET-POINT SET-POINT SET-POINTSET-POINT SET-POINT SET-POINTSET-POINT SET-POINT SET-POINT PRODUCT SELECTION GUIDE SELECTION PRODUCT NO DAYLIGHT NO DAYLIGHT NO NODAYLIGHT DAYLIGHT NO DAYLIGHT NONO DAYLIGHT DAYLIGHT NO DAYLIGHT NO DAYLIGHT

/ KEY LIGHTS FULL ON LIGHTS OFF LIGHTS FULL DIM

PC ADC PC ADC

SPECIFICATIONSAMPLE DAYLIGHT AMPLE DAYLIGHT AMPLE DAYLIGHT PHYSICAL ELECTRICAL - LOW VOLTAGE ELECTRICAL - LINE VOLTAGE ENVIRONMENTAL DEADBAND DIMMING DIMMING

SIZE: 3.63” H x 3.63” W x 1.50” D OPERATING VOLTAGE: LOAD RATING: RANGE OPERATING TEMP: RANGE (9.22 cm x 9.22 cm x 3.81 cm) 12-24 VAC/VDC 800 W @ 120 VAC 14º to 160º F (-10º to 71º C) WEIGHT: 6 oz RECOMMENDED POWER PACK: 1200 W @ 277 VAC STORAGE TEMP: MOUNTING: .5” knockout PP20 1500 W @ SET-POINT347 VAC -14º SET-POINTto 160º F (-26º to 71º C) SET-POINT COLOR: White CURRENT DRAW: MOTOR LOAD: 1/4 HP RELATIVE HUMIDITY: Standard, 4 mA DIMMING LOAD: 20 to 90% non-condensing DIMMING LOAD: Sinks up to 20 mA or 40 ballasts/ ROHS COMPLIANT Sinks up to 20 mA or 40 ballasts/ driversNO DAYLIGHT @ .5 mA each (0-10 VDC NO DAYLIGHT NO DAYLIGHT drivers @ .5 mA each (0-10 VDC dimmable balasts/drivers only) dimmable balasts/drivers only) WIRING DIAGRAM(S): WIRING DIAGRAM(S): See Figure # 22 - 28 on Page 88 - 89 See Figure # 22 - 28 on Page 88 - 89

48 / www.acuitycontrols.com FIXTURE MOUNT DAYLIGHT CONTROLS PRODUCT INFORMATION Fixture Mount Daylight Controls

KEY SPECS SERIES ENCLOSURE CONTROL TYPE POWER TYPE [VDC/VAC] CMB PC Fixture mount box On/off Low 12-24 CMB ADC Fixture mount box Dimming Low 12-24 CMB PC ADC Fixture mount box On/off & dimming Low 12-24 CMRB PC Fixture mount box On/off Line 120/277 CMRB ADC Fixture mount box Dimming Line 120/277 CMRB PC ADC Fixture mount box On/off & dimming Line 120/277

OPTION INFORMATION

DZ 347 LT Dual Zone 347 VAC Low Temp/High Humidity • Provides second output that can control an additional • Allows sensor to be powered from and switch 347 VAC • Sensor electronics are coated for corrosion resistance zone of lighting • Operates down to -40°F/C Stepped Dimming (Duo) Operation (PC Only) • Ideal for A/B (also called inboard/outboard) switching

applications PRODUCT SELECTION GUIDE • Determines the necessary on/off combination of the two poles in order to maintain adequate lighting Percentage Offset Operation • Ideal for classrooms with individually controlled parallel rows of lights • PC sensors use a relative set-point for the second pole that is a percentage of the first pole’s set-point • ADC sensors enable control of an additional 0-10 VDC dimmable ballast or driver at a selected level (voltage) higher than that of the primary zone

LOW VOLTAGE Example: CMB PC DZ LT Series Dual Zone Temp/Humidity

CMB PC (blank) Single Zone (blank) Standard CMB ADC DZ Dual Zone LT Low Temp/High Humidity CMB PC ADC

LINE VOLTAGE Example: CMRB PC DZ LT Series Dual Zone Voltage1 Temp/Humidity

CMRB PC (blank) None (blank) 120/277 VAC (blank) Standard CMRB ADC DZ Dual zone 2 208 208/240 VAC 2 LT Low Temp/High Humidity CMRB PC ADC 347 347 VAC 480 480 VAC 2 Notes 1. 480 and 208 option not available w/dual zone (DZ) 2. CMRB PC Only

www.acuitycontrols.com / 49 PRODUCT INFORMATION Fixture Mount Interchangeable Lens Sensors

Features FIXTURE MOUNT • Four interchangeable lenses - High Bay 360º (6 Lens), High Bay Bi-Directional Aisleway (50 Lens), Large Motion INTERCHANGEABLE LENS / Extended Range 360º (10 Lens), Small Motion / Sensors Standard Range 360º (9 Lens) • Integrated mounting bracket drops lens down 3” from chase nipple – no bracket accessory required Overview • Digital PIR detection – excellent RF immunity The LSXR Family of fixture mount occupancy sensors provides • Single or dual relay versions – designed with robust FIXTURE MOUNT SENSORS FIXTURE MOUNT reliable and versatile solutions for commercial and industrial protection from the harsh switching requirements of T5 lighting control applications. All LSXR Family sensors utilize fluorescent and LED loads passive infrared (PIR) detection and feature interchangeable lenses, providing flexibility for multiple mounting height and • Powers from single or two-phase line connections coverage pattern requirements. • Miswire protection, reversible line & load connections All LSXR Family sensors utilize digital Passive Infrared (PIR) • Push-button programmable detection and power from / switch line voltage. Available • Convenient test mode options include dual relays, HVOLT powering, and an integrated switching / dimming Photocontrol. • Minimum on Timer (LampMaximizer®)

AVAILABLE LENSES

6 50 High Bay 10 Large Motion / 9 Small Motion / High Bay 360° Bi-Directional Aisleway Extended Range 360º Standard Range 360º

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SPECIFICATIONS PHYSICAL ELECTRICAL ENVIRONMENTAL

SIZE (w/ Mounting Flange): MAXIMUM LOAD/POLE (RELAY): OPERATING TEMP:

PRODUCT SELECTION GUIDE SELECTION PRODUCT 3.75” H x 2.50” W x 4.00” D 800 W @ 120 VAC Standard: 14° to 122°F (-10° to 50°C) (9.5 cm x 6.4 cm x 10.2 cm) 1000 W @ 208 VAC LT Option: -40° to 122°F (-40° to 50°C) WEIGHT: 6 oz 1200 W @ 240/277 VAC RELATIVE HUMIDITY: MOUNTING: 1/2 knockout (7/8” hole) on fixture 1500 W @ 347 VAC Standard: 20 to 75% non-condensing MINIMUM LOAD: None 2160 W @ 480 VAC LT Option: 20 to 90% non-condensing COLOR: White MINIMUM LOAD: None (electronics coated for corrosion resistance) FREQUENCY: 50/60 Hz MOTOR LOAD: 1/4 Hp ROHS COMPLIANT FREQUENCY: 50/60 Hz DIMMING LOAD: Sinks < 20 mA (~ 40 LED driver/ballast @ 0.5 per) 0-10 VDC dimmable ballasts or LED drivers only WIRING DIAGRAM(S): See Figure # 18, 19, 20, 21 on Page 87

AVAILABLE OPTIONS

HL 2P AO 2P AOP High/Low Occupancy Operation Alternating Off Relays • Provides high/low control of a 0-10V dimmable fixture • Sequence of operation where both relays close during • Lights are reduced to an energy saving minimum dim periods of occupancy, but only one opens during vacancy level after expiration of occupancy time delay • The relay left closed alternates in order to • If relay is wired, lights will switch off after a second time promote even lamp wear delay • 2P AOP version also includes switching photocontrol

50 / www.acuitycontrols.com PRODUCT INFORMATION Fixture Mount Interchangeable Lens Sensors FIXTURE MOUNT SENSORS

COVERAGE PATTERN

0 m 0 ft 6 High Bay 360º Lens

• Best choice for 15 to 45 ft (4.57 to 13.72 m) mounting heights 4.6 15 • 15 to 20 ft (4.57 to 6.10 m) radial coverage overlaps area lit by a typical LOW VIEW HIGH VIEW high bay fixture 9.1 30 • Excellent detection of large motion 0 ft 0 m (e.g., walking) up to a 35 ft (10.76 m) mounting height 15 4.6 13.7 45 • Excellent detection of extra large motion 6 3 0 m 3 6 9.1 6 3 0 m 3 6 9.1 (e.g., forklifts) up to a 45 ft (13.72 m) 20 10 0 ft 10 20 30 20 10 0 ft 10 20 30 mounting height

50 High Bay Bi-Directional Aisleway Lens

• Provides 50º bi-directional and 10º SIDE VIEW 0 ft 0 m wide coverage pattern 10 3 • 1.2x mounting height equals TOP VIEW approximate detection range in either 20 6 7 2.1

direction 30 9.1 0 ft 0 m • Typical 40 ft (12.19 m) mounting 40 12.2 7 2.1

detects 50 ft (15.24 m) in either 15.2 7.6 0 m 7.6 15.2 15.2 7.6 0 m 7.6 15.2 PRODUCT SELECTION GUIDE direction 50 25 0 ft 25 50 50 25 0 ft 25 50

Large Motion / Extended Range 360º Lens 10 8.5 28

• Best choice for large motion SIDE VIEW TOP VIEW 4.3 14 (e.g., walking) detection 0 ft 0 m

• Viewing angle of 67º in a 360º conical 0 m 0 ft shaped pattern 9 2.7 4.3 14 • Provides 28 ft (8.53 m) radial 8.5 6.4 4.3 2.1 0 m 2.1 4.3 6.4 8.5 coverage when mounted to standard 8.5 28 9 ft (2.74 m) ceiling 28 21 14 7 0 ft 7 14 21 28 • 7 to 15 ft (2.13 to 4.57 m) mounting heights provide 16 to 36 ft (4.88 to 10.97 m) radial coverage

Small Motion / Standard Range 360º Lens 9 3.7 12

• Best choice for small motion (e.g., hand SIDE VIEW TOP VIEW 1.8 6 movements) detection 0 ft 0 m • Viewing angle of 56º in a 360º conical 0 m 0 ft shaped pattern 9 2.7 • Provides 12 ft (3.66 m) radial coverage when 1.8 6 3.7 1.8 0 m 1.8 3.7 mounted to standard 9 ft (2.74 m) ceiling 12 6 0 ft 6 12 3.7 12 • 8 to 15 ft (2.44 to 4.57 m) mounting heights provide 10 to 20 ft (3.05 to 6.10 m) radial coverage

www.acuitycontrols.com / 51 PRODUCT INFORMATION Fixture Mount Interchangeable Lens Sensors: Single Relay

SINGLE RELAY Specifications subject to change. Example: LSXR 6 HL LT Series Lens Option Dimming/Photocontrol Voltage

LSXR Passive Infrared Single Lens Multi-Lens (blank) None (blank) 120-277 VAC (MVOLT) Indoor Occupancy Sensor (blank) No Lens 610 High Bay 360º / Large Motion / HL High/Low Occupancy HVOLT 347-480 VAC Operation 6 High Bay 360° Extended Range 360º P Photocontrol 50 High Bay 650 High Bay 360º / Bi-Directional Aisleway High Bay Bi-Directional Aisleway ADC Photocontrol

FIXTURE MOUNT SENSORS FIXTURE MOUNT with Dimming 10 Large Motion / 3PK High Bay 360º / Small Motion / ANL Combination Dimming Extended Range 360º Standard Range 360° / High Bay Bi-Directional Aisleway &Switching Photocontrol 9 Small Motion / w/ High/Low Occupancy Operation Standard Range 360º 4PK All Lenses

Max Dim Level* Min Dim Level* Lead Length* Temp/Humidity Default Time Delay* Pack Qty

(blank) 10 VDC (blank) Min (blank) 8" (blank) None (blank) 10 min (w/15 min minimum on time) (blank) Single 9H 9 VDC 1V 1 VDC 42L 42" LT Low Temp/ 5M 5 min (LED only) J100 100-Pack 8H 8 VDC 2V 2 VDC High Humidity 15M 15 min 7H 7 VDC 3V 3 VDC 20M 20 min 4V 4 VDC 30M 30 min 5V 5 VDC 6V 6 VDC

*Option available in 100-Pack quantities only (add J100 option)

PRODUCT INFORMATION Fixture Mount Interchangeable Lens Sensors: Dual Relay

DUAL RELAY Specifications subject to change. Example: LSXR 610 2P AO J100 Series Lens Option 2P Operating Mode Voltage

LSXR Passive Infrared Single Lens Multi-Lens 2P Dual Relay (blank) None (blank) 120/277 VAC Indoor Occupancy Sensor (blank) No Lens 610 High Bay 360º / Large Motion / AO Alternating Off Relays 347 347 VAC (promotes even lamp wear) 6 High Bay 360° Extended Range 360º 650 High Bay 360º / AOP Alternating Off Relays 50 High Bay with Photocell Bi-Directional Aisleway High Bay Bi-Directional Aisleway P Photocontrol On/Off-both 10 Large Motion / 3PK High Bay 360º /Small Motion / Poles (single set-point) PRODUCT SELECTION GUIDE SELECTION PRODUCT Extended Range 360º Standard Range 360° / High Bay Bi-Directional Aisleway SZ Photocontrol On/Off 9 Small Motion / (Pole 1 only) 4PK All Lenses Standard Range 360º DZ Photocontrol On/Off-both Poles (dual set-point)

Lead Length* Temp/Humidity Default Time Delay* Pack Qty

(blank) 8" (blank) None (blank) 10 min (w/15 min minimum on time) (blank) Single 42L 42" LT Low Temp/High Humidity 5M 5 min (LED only) J100 100-Pack 15M 15 min 20M 20 min 30M 30 min

*Option available in 100-Pack quantities only (add J100 option)

PRODUCT INFORMATION Fixture Mount Interchangeable Lens Sensors: Accessory Lenses

ACCESSORY LENSES Specifications subject to change. Example: LENS 6 J10 Series Len Type Pack Quantity

LENS 6 High Bay 360° (blank) Single 50 High Bay Bi-Directional Aisleway J10 10-pack 10 Large Motion / Extended Range 360º J100 100-pack 9 Small Motion / Standard Range 360º

52 / www.acuitycontrols.com

PRODUCT INFORMATION Fixture Mount Interchangeable Lens Daylight Control Sensors FIXTURE MOUNT INTERCHANGEABLE LENS DAYLIGHT CONTROL Switching & Dimming Sensors Features • Integrated mounting bracket drops lens down 3” from chase nipple – no bracket accessory required • Single or dual relay versions – designed with robust Overview protection from the harsh switching requirements of T5 On/off photocontrol and dimming sensors provide intelligent fluorescent and LED loads

FIXTURE MOUNT DAYLIGHT CONTROL SENSORS CONTROL DAYLIGHT FIXTURE MOUNT control of lighting for indoor daylight applications ideal for spaces with windows, such as vestibules, corridors, classrooms • Powers from single or two-phase line connections or offices, the sensors work by monitoring daylight conditions • Miswire protection, reversible line & load connections in a room, then controlling the lighting to ensure that • Photocontrol and 0-10 VDC dimming options adequate lighting levels are maintained. • Push-button programmable Line voltage sensors integrate a line switching relay and/or • Convenient test mode power off the line. Dimming photocontrol sensors are capable of controlling any 0-10 VDC dimmable ballast or driver. • Minimum on Timer (LampMaximizer®)

SOLUTION TYPES / KEY LIGHTS/ KEYFULL ON LIGHTSLIGHTS/ KEY FULL OFF ON LIGHTSLIGHTSLIGHTS FULL FULL OFF DIM ON LIGHTSLIGHTS FULL OFF DIM LIGHTS FULL DIM

PC ADC PC ADC Automatic On/Off Switching Automatic Dimming Control Combination On/Off & Dimming Control

PC PC ADCPC ADC PCADC ADC PC ADC PC ADC AMPLE DAYLIGHT AMPLE DAYLIGHTAMPLEAMPLE DAYLIGHT DAYLIGHT AMPLE DAYLIGHT AMPLEAMPLE DAYLIGHT DAYLIGHT AMPLE DAYLIGHT AMPLE DAYLIGHT DEADBAND DEADBAND DEADBAND DIMMING DIMMING DIMMING DIMMING DIMMING DIMMING RANGE RANGE RANGE RANGE RANGE RANGE

SET-POINT SET-POINT SET-POINTSET-POINT SET-POINT SET-POINTSET-POINT SET-POINT SET-POINT

NO DAYLIGHT NO DAYLIGHT NO NODAYLIGHT DAYLIGHT NO DAYLIGHT NONO DAYLIGHT DAYLIGHT NO DAYLIGHT NO DAYLIGHT PRODUCT SELECTION GUIDE SELECTION PRODUCT

/ KEY LIGHTS FULL ON LIGHTS OFF LIGHTS FULL DIM

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. PC ADC PC ADC SPECIFICATIONS PHYSICAL ELECTRICAL AMPLE DAYLIGHT AMPLEENVIRONMENTAL DAYLIGHT AMPLE DAYLIGHT

SIZE (w/ Mounting Flange): MAXIMUM LOAD/POLE (RELAY): OPERATING TEMP: DEADBAND 3.75” H x 2.50” W x 4.00” D 800 W @ 120 VAC Standard:DIMMING 14° to 122°F (-10° to 50°C) DIMMING RANGE RANGE (9.5 cm x 6.4 cm x 10.2 cm) 1000 W @ 208 VAC LT Option: -40° to 122°F (-40° to 50°C) WEIGHT: 6 oz 1200 W @ 240/277 VAC RELATIVE HUMIDITY: MOUNTING: 1/2 knockout (7/8” hole) on fixture 1500 W @ 347 VAC SET-POINT Standard: 20 to 75% non-condensingSET-POINT SET-POINT MINIMUM LOAD: None 2160 W @ 480 VAC LT Option: 20 to 90% non-condensing COLOR: White MINIMUM LOAD: None (electronics coated for corrosion resistance) FREQUENCY: 50/60 Hz MOTOR LOAD: 1/4 Hp NO DAYLIGHT ROHS COMPLIANTNO DAYLIGHT NO DAYLIGHT FREQUENCY: 50/60 Hz DIMMING LOAD: Sinks < 20 mA (~ 40 LED driver/ballast @ 0.5 per) 0-10 VDC dimmable ballasts or LED drivers only WIRING DIAGRAM(S): See Figure # 18, 19, 20, 21 on Page 87

54 / www.acuitycontrols.com FIXTURE MOUNT DAYLIGHT CONTROL SENSORS

PRODUCT INFORMATION Fixture Mount Interchangeable Lens Daylight Control Sensors

AVAILABLE OPTIONS**

LT HVOLT **For options and Low Temp/High Humidity 347 - 480 VAC detailed information on wiring and sequence • Sensor electronics are coated for corrosion resistance • Allows sensor to be powered from and switch of operation visit 347-480 VAC • Operates down to -40° F/20°C (-4° F/20° C for PDT) http://bit.ly/1KNm1Lg

SINGLE RELAY Specifications subject to change. Example: change to: LSXR PC HVOLT 9H J100 Series Voltage

LSXR PC (blank) 120-277 VAC (MVOLT) LSXR ADC HVOLT 347-480 VAC LSXR PC ADC PRODUCT SELECTION GUIDE

Max Dim Level* Min Dim Level* Lead Length* Temp/Humidity Pack Qty

(blank) 10 VDC (blank) 0 VDC (blank) 8" (blank) None (blank) Single 9H 9 VDC 1V 1 VDC 42L 42" LT Low Temp/ J100 100-Pack 8H 8 VDC 2V 2 VDC High Humidity 7H 7 VDC 3V 3 VDC 4V 4 VDC 5V 5 VDC 6V 6 VDC *Option available in 100-Pack quantities only (add J100 option)

www.acuitycontrols.com / 55 PRODUCT INFORMATION Wide View & Hallway Sensor WIDE VIEW & HALLWAY Sensors

Overview (Line voltage) Overview (Low voltage) Line voltage wide view and hallway sensors are ideal for retrofit applications. Line voltage Low voltage wide view sensors are designed to mount in a corner and detect small motions up to sensors are powered by and directly switch line voltage; therefore, no power packs are needed. 40 ft (12.19m) away and larger motions up to 70 ft (21.34 m) away. This makes them ideal for 30 x Additionally, these sensors do not require a neutral, making wiring directly off local switches a 30 ft (9.14 x 9.14 m) classrooms or corridors up to 70 ft (12.19 m) long. Low voltage hallway units convenient option. Together, these features make them perfect for retrofit applications, where detect occupants entering a hallway up to 130 ft (39.64 m) away. running new wiring is difficult. The enclosure’s convenient tilting feature enables the sensor to be mounted at any height from 8 WIDE VIEW / HALLWAY SENSORS / HALLWAY VIEW WIDE For rooms with obstructions, wide view sensors are available with dual technology, which to 10 ft (2.44 to 3.05 m). When corner or wall mounting is not possible, the WV-BR ceiling bracket adds Microphonics™ detection to the Passive Infrared (PIR) detection. For rooms that need accessory can be used to mount the sensor to the ceiling. independent control of two circuits, 2-pole units are available. These sensors can be used in combination with other low voltage sensors to cover oddly shaped Features (Line voltage) rooms. For rooms with obstructions, wide view sensors are available with dual technology, which • Passive Dual Technology (PDT) utilizes • Self-contained relay(s) adds Microphonics™ detection to the Passive Infrared (PIR) detection. PIR/Microphonics™ detection • No power pack(s) needed Features (Low voltage) • Miswire protection, reversible line and • No minimum load • Passive Dual Technology (PDT) utilizes • Push-button programmable load connections PIR/Microphonics™ detection • Green LED status indicator • Minimum On Timer (LampMaximizer®) • 30 sec to 30 min time delay • 30 sec to 30 min time delay • Convenient test mode • Digital PIR detection - • Digital PIR detection - • Green LED status Indicator excellent RF immunity excellent RF immunity

ENCLOSURES

SPECIFICATIONS PHYSICAL ELECTRICAL - LOW VOLTAGE ENVIRONMENTAL

SIZE: 3.00” H x 3.60” W x 1.75” D OPERATING VOLTAGE: OPERATING TEMP: (7.62 cm x 9.94 cm x 4.45 cm) 12-24 VAC/VDC 14º to 160º F (-10º to 71º C) WEIGHT: 4 oz RECOMMENDED POWER PACK: STORAGE TEMP: MOUNTING: PP20 -14º to 160º F (-26º to 71º C) Directly to corner or to ceiling CURRENT DRAW: RELATIVE HUMIDITY: using WV-BR bracket Standard, 4 mA 20 to 90% non-condensing COLOR: White WIRING DIAGRAM(S): ROHS COMPLIANT See Figure # 14 on Page 86

SPECIFICATIONS PHYSICAL ELECTRICAL - LINE VOLTAGE ENVIRONMENTAL

SIZE: 4.96” H x 3.10” W x 1.70” D LOAD RATING: OPERATING TEMP: (12.60 cm x 7.87 cm x 4.32 cm) 800 W @ 120 VAC 14º to 85º F (-10º to 29º C)

PRODUCT SELECTION GUIDE SELECTION PRODUCT WEIGHT: 7 oz 1200 W @ 277 VAC STORAGE TEMP: MOUNTING: 1500 W @ 347 VAC -14º to 85º F (-26º to 29º C) Single gang handy or wiremold MOTOR LOAD: 1/4 HP RELATIVE HUMIDITY: corner box #V5719 FREQUENCY: 50/60 Hz 20 to 90% non-condensing COLOR: White, Ivory WIRING DIAGRAM(S): ROHS COMPLIANT See Figure # 15-17 on Page 86

COVERAGE PATTERNS

13 End-of-Hallway Lens SIDE VIEW TOP VIEW

0 ft 0 m 10 3 • Large motion (e.g., walking) detection up to 130 ft (39.62 m) 5 1.5 0 ft 0 m • Designed for 7 ft (2.13 m) high mounting at end of hall 10 3 10 3 0 m 3 15.2 27.4 39.6 0 m 3 15.2 27.4 39.6 0 ft 10 50 90 130 0 ft 10 50 90 130

TOP VIEW 16 Wide View 120° Lens 40 12.2

30 9.1 • Small motion (e.g., hand movements) SIDE VIEW detection up to 40 ft (12.19 m) 20 6 • Large motion (e.g., walking) detection 0 ft 0 m

up to 70 ft (21.34 m) 10 3 • Designed for 8 to 10 ft (2.44 to 3.05 m) high mounting in room corner 9 2.7 0 ft 0 m 0 m 3 6 9.1 12.2 9.1 6 3 0 m 3 6 9.1 0 ft 10 20 30 40 30 20 10 0 ft 10 20 30

56 / www.acuitycontrols.com PRODUCT INFORMATION Wide View & Hallway Sensor: Low Voltage WIDE VIEW / HALLWAY SENSORS

Electrical Specs KEY SPECS Operating Voltage SERIES ENCLOSURE DETECTION POWER TYPE [VDC/VAC] 12-24 VDC/VAC Recommended Power Supply WV 16 120° Wide view PIR 12-24 PP20 WV PDT 16 120° Wide view Dual Technology 12-24 Current Draw 4 mA w/ R option 16 mA HW13 Hallway PIR 12-24 Wiring Diagram(s) See Figure # 14, 15, 16, 17 on Page 86

OPTION INFORMATION

R P KIT Low Voltage Relay Photocontrol Ceiling Mount Bracket • Enables low voltage sensors to interface with other • Auto set-point calibration • Includes ceiling mountable bracket, an alternative systems (e.g. BMS, lighting panels) to wall mounting • On/off mode: Full on/off control of lighting during • Provides dry contact closure via a SPDT, 1 amp, periods of occupancy with adequate daylight • Bracket (shown on right) also sold 30 volt relay (resistive loads only) separately (model # WV BR) • Inhibit mode: Prevents lights from turning on if adequate daylight is available, but does not turn lights off LT Low Temp/High Humidity • Sensor electronics are coated for corrosion resistance • Operates down to -40° F/20°C (-4° F/20° C for PDT)

LOW VOLTAGE Specifications subject to change. Example: WV PDT 16 R P LT Series Relay Photocontrol Temp/Humidity Bracket Kit

WV 16 (blank) None (blank) None (blank) Standard (blank) Sensor only WV PDT 16 R Low Voltage Relay P Photocontrol LT Low Temp/High Humidity KIT Sensor and WV BR HW13 bracket PRODUCT SELECTION GUIDE

PRODUCT INFORMATION Wide View & Hallway Sensor: Line Voltage

Electrical Specs KEY SPECS Load Rating SERIES ENCLOSURE DETECTION POWER TYPE (VAC) 13 Amps @ 120-347 VAC Motor Load 1/4 Hp WVR 16 120° Wide view PIR 120/277 Frequency 50/60 Hz WVR PDT 16 120° Wide view Dual Technology 120/277 Wiring Diagram(s) See Figure # 14, 15, 16, 17 on Page 86 HWR13 Hallway PIR 120/277

OPTION INFORMATION

2P 347 LT Dual Relay (Available for WVR Models Only) 347 VAC Low Temp/High Humidity • Provides a second line voltage switching relay • Allows sensor to be powered from and switch 347 VAC • Sensor is corrosion-resistant to moisture • Operates down to -40° F/C (-4° F/20° C for PDT) SN No Switch (Available for HWR13 Only) • Sensor available without switch

WIDE VIEW, LINE VOLTAGE Specifications subject to change. Example: WVR 16 WH LT Series Poles Voltage Color Temp/Humidity

WVR 16 (blank) 1-pole (blank) 120/277 VAC WH White (blank) Standard WVR PDT 16 2P 2-pole 347 347 VAC IV Ivory LT 1 Low Temp/High Humidity

Notes 1. LT option not available for WVR PDT 16

HALLWAY, LINE VOLTAGE Specifications subject to change. Example: HWR13 347 WH Series Switch Voltage Color

HWR13 (blank) w/ Switch (blank) 120/277 VAC WH White SN No Switch 347 347 VAC IV Ivory

www.acuitycontrols.com / 57 PRODUCT INFORMATION Outdoor Motion Sensors

Overview Features (All) OUTDOOR The SBOR xx ODP and SBO xx ODP Series sensors provide both • Miswire protection, reversible line & load connections motion and daylight based control of a 0-10 VDC dimmable Pole/Fixture Mount • Digital PIR detection - excellent RF immunity outdoor or wet location luminaire. Designed to mount Motion Sensors directly through a 1/2” knockout (7/8” hole) in a light fixture • Self-contained relay for switching or pole, the SBOR xx ODP can both directly switch and dim its • Gasketed for outdoor operation connected lighting load. The low voltage SBO xx • Enables fixture or pole mounting ODP version requires a power pack to switch. Both versions are

OUTDOOR SENSORS tuned for walking size motion while preventing false tripping • Multiple sensor body and bracket configurations from the environment. All units also have an integrated available Photocontrol that switches lights off during daytime periods • Adjustable time delays when there is sufficient daylight. • Programming button accessible without opening sensor For non-dimming outdoor motion sensor applications or removing gaskets the SBOR xx OEX and SBO xx OEX Series sensors are Features (-ODP versions only) recommended. • Photocontrol controls relay (on/off) • Motion sensor controls dimming output (0-10 VDC) • Compatible w/ 0-10 VDC dimmable ballasts and LED drivers • Adjustable max/min dim levels and ramp rates

ENCLOSURES

APPLICATION/COVERAGE

PRODUCT SELECTION GUIDE SELECTION PRODUCT Large Motion / Extended Range 360º Lens 10 8.5 28

• Best choice for large motion SIDE VIEW TOP VIEW 4.3 14 (e.g., walking) detection 0 ft 0 m

• Viewing angle of 67º in a 360º conical 0 m 0 ft shaped pattern 9 2.7 • Provides 28 ft (8.53 m) radial 4.3 14 8.5 6.4 4.3 2.1 0 m 2.1 4.3 6.4 8.5 coverage when mounted to standard 9 ft (2.74 m) ceiling 28 21 14 7 0 ft 7 14 21 28 8.5 28 • 7 to 15 ft (2.13 to 4.57 m) mounting heights provide 16 to 36 ft (4.88 to 10.97 m) radial coverage

6 High Bay 360º Lens 0 m 0 ft

• Best choice for 15 to 45 ft (4.57 to 13.72 m) mounting heights • 15 to 20 ft (4.57 to 6.10 m) radial 4.6 15 coverage overlaps area lit by a typical high bay fixture LOW VIEW HIGH VIEW • Excellent detection of large motion 9.1 30 (e.g., walking) up to a 35 ft (10.76 m) 0 ft 0 m mounting height • Excellent detection of extra large motion 15 4.6 13.7 45 (e.g., forklifts) up to a 45 ft (13.72 m) 6 3 0 m 3 6 9.1 6 3 0 m 3 6 9.1 mounting height 20 10 0 ft 10 20 30 20 10 0 ft 10 20 30

58 / www.acuitycontrols.com PRODUCT INFORMATION Outdoor Motion Sensors: Line Voltage

SPECIFICATIONS OUTDOOR SENSORS PHYSICAL ELECTRICAL ENVIRONMENTAL

SIZE: 3.35” H or 4.88” H x 4.40” W x 4.00” D MAXIMUM SWITCHING LOAD: OPERATING TEMP: -40º to 160º F (-40º to 71º C) (8.51 cm or 12.40 cm x 11.18 cm x 10.16 cm) 800 W @ 120 VAC IP66 RATED WEIGHT: 9 oz 1000 W @ 208 VAC ROHS COMPLIANT MOUNTING: 1/2” knockout (7/8” hole) 1200 W @ 240 VAC 1200 W @ 277 VAC COLOR: White, Black, or Dark Bronze 1500 W @ 347 VAC 2160 W @ 480 VAC MINIMUM LOAD: None MOTOR LOAD: 1/4 HP FREQUENCY: 50/60 Hz DIMMING LOAD: Sinks < 20 mA (0-10 VDC LED Drivers / Ballasts) WIRING DIAGRAM(S): See Figure # 11,12, 13 on Page 85

LINE VOLTAGE Specifications subject to change. Example: SBOR 10 ODP EB3 BK 3V Series Lens/Mounting Height Dimming/Photocontrol Voltage Body / Bracket Color Min Dim Level1

SBOR 10 Low Mount (8-15 ft) OEX None (blank) 120/277 VAC (MVOLT) (blank) Short extension, WH White OV 0 VDC 6 High Mount (15-30 ft) low back BK Black OEX D Motion Controlled High/Low HVOLT 347-480 VAC 1V 1 VDC Dimming EB1 Short extension, BZ Dark Bronze high back 2V 2 VDC OEX P Photocontrol (On/Off) EB2 Long extension, 3V 3 VDC ODP Combination Motion low back Controlled Dimming 4V 4 VDC and Photocontrol EB3 Long extension, 5V 5 VDC high back PRODUCT SELECTION GUIDE Notes 1. Required for D or ODP options

PRODUCT INFORMATION Outdoor Motion Sensors: Low Voltage

SPECIFICATIONS PHYSICAL ELECTRICAL ENVIRONMENTAL

SIZE: 3.35” H or 4.88” H x 4.40” W x 4.00” D OPERATING VOLTAGE: OPERATING TEMP: (8.51 cm or 12.40 cm x 11.18 cm x 10.16 cm) 12-24 VAC/VDC -40º to 160º F (-40º to 71º C) WEIGHT: 9 oz CURRENT DRAW: 4 mA IP66 RATED MOUNTING: 1/2” knockout (7/8” hole) RECOMMENDED POWER PACK: ROHS COMPLIANT PP20 / MP20 / MP5 480 COLOR: White, Black, or Dark Bronze DIMMING LOAD: Sinks < 20 mA (0-10 VDC LED Drivers / Ballasts) WIRING DIAGRAM(S): See Figure # 11,12, 13 on Page 85

LOW VOLTAGE Specifications subject to change. Example: SBO 10 ODP BK 3V Series Lens/Mounting Height Dimming/Photocontrol Body / Bracket Color Min Dim Level1

SBO 10 Low Mount (8-15 ft) OEX None (blank) Short extension, WH White OV 0 VDC 6 High Mount (15-30 ft) low back BK Black OEX D Motion Controlled High/Low Dimming 1V 1 VDC EB1 Short extension, BZ Dark Bronze OEX P Photocontrol (On/Off) high back 2V 2 VDC ODP Combination Motion Controlled Dim- EB2 Long extension, 3V 3 VDC ming and Photocontrol low back 4V 4 VDC EB3 Long extension, 5V 5 VDC high back

Notes 1. Required for D or ODP options

www.acuitycontrols.com / 59 PRODUCT INFORMATION Power Packs & Secondary Packs

Overview POWER PACKS Power packs are the heart of the low voltage sensor system. There are several different types of power packs, each with a & Secondary Packs A power pack may transform Class I high voltage (120-277 VAC unique combination of features. The most versatile power pack or 347 VAC) to Class II 15 VDC for powering remote sensors. is the PP20, which utilizes a patented relay contact protection A power pack also switches the lighting load on and off and can power up to 14 sensors. Multi-circuit control can using its internal relay. Class II wire leads connect to 18 be handled by multiple PP20s, 2-pole power packs (PP20 AWG or smaller low voltage cable running to the sensors, 2P), or combination power pack and secondary pack (SP20)

POWER PACKS making installation easy and clean. Power packs also have an configurations. elongated mounting nipple that allows them to be mounted either directly through a ½ inch knockout into a junction box, or inside an adjacent box for meeting specific local code requirements in ceiling plenums.

ENCLOSURES

SINGLE POLE UNITS 2-POLE UNITS SIZE H: 3.00” (7.62 cm) SIZE H: 4.13” (10.49 cm) W: 2.25" (5.72 cm) W: 3.00” (7.62 cm) D: 1.88" (4.78 cm) D: 1.88” (4.78 cm) WEIGHT 6 oz WEIGHT 6 oz MOUNTING .5" knockout MOUNTING .5" knockout COLOR Black COLOR Black

Plenum Rated Plenum Rated

POWERING CAPACITY

A power pack’s transformer can supply up to 150 mA of power @15 VDC. Each relay requires 40 mA during the On state. Low voltage remote sensors typically require 3 mA when detecting occupants, and 0.15 mA when in standby. Therefore, each transformer can handle up to 3 relays (including the relay(s) inside the power pack). For example, one PP20 can power its relay (40 mA) and 110 mA of external devices. Because of the ultra low current design of the sensors, up to 14 or more sensors can be connected to a single power pack. If multiple power packs are used together, an additional 110 mA is available.

POWER SPECS SERIES SENSORS SENSORS w/ R OPTION1 [1] PP20 (or MP20) 14 8 [1] PP20 2P 7 6 [1] PP20 w/SP20 (or MP20 w/ MSP20) 7 6 PRODUCT SELECTION GUIDE SELECTION PRODUCT [1] PP20 2P w/ SP20 5 5 Notes Table information reflects usage with 120/277 or 347 VAC power

1. The "R" option for sensors adds an isolated low voltage auxiliary relay. Only one sensor with this option is typically needed per room

SECONDARY PACK VS. POWER PACK

A secondary pack (also called an auxiliary relay) contains the A power supply contains the same transformer as a power same switching relay as a normal power pack, though it does pack, though it does not contain a relay. Power supplies are not contain the transformer. Secondary packs can be used ideal for supplying power to devices, such as the CM ADC, in applications where power is supplied from another power which does not need to switch line voltage. pack. Secondary packs are available with (SP20 version) and without (MSP20 version) relay contact protection.

OPTION INFORMATION

347 LT 347 VAC Low Temp/High Humidity • Allows power pack to be powered from and/or switch 347 VAC • Power Pack electronics are coated for corrosion resistance • Operates down to -40°F/C

60 / www.acuitycontrols.com PRODUCT INFORMATION Power Packs & Secondary Packs

Electrical Specs KEY SPECS

Wiring Diagram(s) SERIES RELAY CONTACT PROTECTION TRANSFORMER # OF POLES (RELAYS) SWITCHING LOAD RELAY TYPE POWER PACKS See Figure # 29, 30, 31, 32, 33, 34, on Page 90-91 PP20 Yes Yes 1 20A / 1 HP Electrically Held PP20 2P Yes Yes 2 20A / 1 HP Electrically Held SP20 Yes No 1 20A / 1 HP Electrically Held Alternating Electrically PP 2PAR Yes Yes 2 20A / 1 HP Held MP20 No Yes 1 20A / 1 HP Electrically Held MSP20 No No 1 20A / 1 HP Electrically Held PP20 SH Yes Yes 1 20A / 1 HP Electrically Held PP 2PM Yes Yes 2 20A / 1 HP Momentary MP5 480 No Yes 2 5A / 0.25HP Electrically Held

ORDERING INFORMATION Specifications subject to change. Example: PP20 347 LT Series Voltage1 Temp/Humidity

PP20 (blank) 120/277 VAC (blank) Standard PP20 2P 347 347 VAC LT Low Temp/High Humidity SP20 PRODUCT SELECTION GUIDE MP20 MSP20 PP20 SH PP 2PM PP 2PAR MP5 480

Notes 1. 347 option only available on PP20, SP20, and MP20

www.acuitycontrols.com / 61 PRODUCT INFORMATION Fixture Embedded - Micro Enclosure (Indoor)

Overview Automatic dimming Photocontrol (optional) MICRO The Sensor Switch MSD 7 is a passive infrared (PIR) occupancy During periods of occupancy but no daylight, the sensor will sensor designed to be easily embedded into luminaires. raise the dim level to its full bright setting (default 10 VDC). As ENCLOSURE This “micro” sensor directly wires to 0-10 VDC dimmable LED daylight increases and begins to contribute to the overall light drivers and fluorescent ballasts, providing occupancy based level of the room, the sensor starts dimming the ballast/driver Indoor high/low dimming control. The MSD 7 provides excellent line proportionally. At the point when sufficient daylight is present of sight 360º PIR detection of both small motion and walking to maintain the set-point without any contribution from the motion making it ideal for small rooms or offices without lights, the sensor will hold the ballast/driver at its minimum

MICRO ENCLOSURE obstructions or areas with primarily walking motion (e.g. dim level setting. When daylight levels fall below the set-point corridors, library stacks). For outdoor applications, the MSOD 7 again, the sensor will start increasing the brightness of the ODP sensor provides both Motion and Daylight based control ballast/driver in order to raise the overall light level. Finally, at of a 0-10 VDC dimmable outdoor or wet location luminaire. the point when all daylight contribution is gone, the ballast/ driver will again be at its full bright level (default 10 VDC). High/low occupancy sensor operation The sensor indicates occupancy when changes in the infrared Light level set-point energy within its field-of-view are detected. Once occupancy The dimming Photocontrol functions by comparing the is detected, the 0-10 VDC ouput will ramp up to its full bright amount of daylight available with a defined acceptable setting. An internal time delay, factory set at 10 minutes, lighting level called the set-point. The sensor can find its keeps the sensor in the occupied state (full bright) during optimum set-point via the Automatic Set-Point Programming brief periods of inactivity. The timer is adjustable, and is reset mode. In this mode, the sensor takes light readings at full every time occupancy is re-detected. After the occupancy time bright and full dim in order to determine how much artificial delay expires, the sensor will dim the lights down to the user light it is controlling. It then sets the minimum light level selected minimum dim level where it will stay until occupancy to be equal to this amount. It is assumed that the space is is redetected. adequately lit by design, however, if this is not the case the set- point may be easily adjusted to the occupant’s preferences. All modes and settings are entered digitally via a push button sequence. Once programmed, the exact value of the set-point (in foot candles) can be read out from the sensor via a series of LED flashes.

COVERAGE PATTERNS

Micro Enclosure (Indoor) • Recommended for walking motion detection • Provides 12 ft (3.66 m) radial detection of small motion • Initial detection will occur earlier when walking from mounting heights between 8 ft (2.44 m) when mounted at 9 ft (2.74 m). across sensor’s field of view than when walking and 20 ft (6.10 m). directly at sensor. • At the 7.5 ft (2.29 m) hanging height of a typical pendant • Initial detection of walking motion along sensor axes at or suspended mount fixture the sensor provides 10 ft distances of 2x the mounting height up to 15 ft (4.57 m) (3.05 m) radial detection of small motion. and 1.75x up to 20 ft (6.10 m). 9 FT MOUNTING 15 FT MOUNTING 5.5 18 9.2 30 4.6 15 7.4 24 3.7 12 5.4 18 9.2 30 2.7 9 3.6 12 7.4 24 1.8 6 SIDE VIEW TOP VIEW 5.4 18 1.8 6

PRODUCT SELECTION GUIDE SELECTION PRODUCT 0.9 3 3.6 12 0 ft 0 m 0 m 0 ft 0 m 0 ft 1.8 6 0.9 3 1.8 6 0 m 0 ft 1.8 6 1.8 6 3.6 12 2.7 9 15 4.6 3.6 12 5.4 18 9.2 7.4 5.4 3.6 1.8 0 m 1.8 3.6 5.4 7.4 9.2 3.7 12 5.4 18 7.4 24 9.2 7.4 5.4 3.6 1.8 0 m 1.8 3.6 5.4 7.4 9.2 4.6 15 30 24 18 12 6 0 ft 6 12 18 24 7.4 30 24 30 24 18 12 6 0 ft 6 12 18 24 30 9.2 30 9.2 30 5.5 18 Lens rotates15° to enable adjustment

5.5 18 ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. 4.6 15 LOW VIEW TOP VIEW 3.7 12 SPECIFICATIONS 2.7 9 0 ft 0 m 1.8 6 PHYSICAL ELECTRICAL 0.9 3 ENVIRONMENTAL SIZE: 1.34”H x 2.60”W x 1.18”D OPERATING VOLTAGE: 0 m 0 ft OPERATING TEMP: 0.9 3 ( 3.40 cm x 6.65 cm x 2.99 cm ) 12 - 24 VDC 14º to 160ºF (-10º to 71ºC) 9 2.7 1.8 6 SENSOR WEIGHT: 3 oz CURRENT DRAW: 2.7 9 RELATIVE HUMIDITY: SENSOR 5.4MOUNTING: 4.6 3.6 2.7 1.8 0.9 0 m 0.9 1.8 2.7 3.6 4.6 5.4 Standard, 4 mA 3.7 12 20 to 90% non-condensing Required 18 15 Hole 12 Size 9 1.125” 6 3 0 ft 3 6 9 12 15 18 4.6 15 DIMMING LOAD: 5.5 18 ROHS COMPLIANT Material Thickness 0.25” max Sinks < 20 mA; ~40 ballasts / LED drivers (0-10 VDC) WIRING DIAGRAM(S): See Figure # 41 on Page 93

ORDERING INFORMATION Specifications subject to change. Example: MSD 7 WH 0V Series Automatic Dimming Control Min Dim Level*

MSD 7 Indoor Micro Sensor (Blank) None 0V 0 VDC 3V 3 VDC ADC Integrated Dimming Photocontrol 1V 1 VDC 4V 4 VDC 2V 2 VDC 5V 5 VDC

*Level after occupancy time delay expires

62 / www.acuitycontrols.com PRODUCT INFORMATION Fixture Embedded - Micro Enclosure (Outdoor)

Overview MICRO ENCLOSURE The MSOD 7 ODP Series sensor provides both Motion and MICRO Daylight based control of a 0-10 VDC dimmable outdoor or wet location luminaire. For motion detection, the sensor utilizes ENCLOSURE 100% Digital Passive Infrared (PIR) technology that is tuned for walking size motion while preventing false tripping from Outdoor the environment. The unit’s integrated Photocontrol enables additional energy savings during daytime periods when there is sufficient daylight. The MSD 7 sensor is recommended for indoor embedded applications.

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com.

Sequence Of Operation - Motion Sequence Of Operation - Daylight Sequence of Operation For outdoor applications, where safety is of primary concern, To prevent lights from day-burning, the MSOD 7 ODP Series When time delay expires, lights ramp down to minimum over 5 min the MSOD 7 ODP Series sensor is factory set to start dimming sensor will dim lighting completely to a ~0 VDC control level MOTION NO MOTION MOTION MAX the lights once the motion time delay expires. Set to 5 min during periods of sufficient daylight. Ideally the MSOD 7 ODP B by default, this time delay is followed by a 5 min ramp down is used with an LED driver that interprets this ~0 VDC control Lights Ramp B Down When period where the lights slowly drop to the minimum dim level. level as an off or sleep mode signal. Providing this type of Pho- A Time Delay 3 Second

Utilizing a long ramp down rate eliminates noticeable drops in tocontrol control eliminates the need for astronomical or time LEVEL LIGHT Expires Ramp Up light level. If motion is detected at any time during the ramp clocks. Additionally, the sensor’s closed loop Photocontrol A MIN down period or when at the minimum dim level, the sensor adjusts its calibration after every cycle to accommodate visual 5 Min 5 Min Lights @ will quickly ramp the lights back up to maximum level (default changes to the space in which they are installed (for example Time Delay Ramp Down Min Power 100%) over a 3 sec (default) period. This ramp up period is different color cars in a parking garage reflecting light differ- 0 5 10 15 20 25 30 intended to quickly return the lighting to full bright without ently). The Photocontrol operation can also be configured to TIME (mins) distracting occupants with a sudden jump in the space’s light just dim lights to the specified minimum dim level (i.e. the level. The time delays, ramp rates, and max/min dim levels are level used after motion time delay expires) instead of to 0 VDC. user adjustable via the accessible push-button. The default setpoint of the Photocontrol is set to 200fc so that slight light level changes will not effect operation.

COVERAGE PATTERNS

Micro Enclosure (Outdoor) PRODUCT SELECTION GUIDE • Recommended for walking motion detection • Provides 12 ft (3.66 m) radial detection of small motion • Initial detection will occur earlier when walking from mounting heights between 8 ft (2.44 m) when mounted at 9 ft (2.74 m). across sensor’s field of view than when walking and 20 ft (6.10 m). directly at sensor. • Initial detection of walking motion along sensor axes at distances of 2x the mounting height up to 15 ft (4.57 m) and 1.75x up to 20 ft (6.10 m). 9 FT MOUNTING 15 FT MOUNTING 5.5 18 9.2 30 4.6 15 7.4 24 3.7 12 5.4 18 9.2 30 2.7 9 3.6 12 7.4 24 1.8 6 SIDE VIEW TOP VIEW 5.4 18 0.9 3 1.8 6 3.6 12 0 ft 0 m 0 m 0 ft 0 m 0 ft 1.8 6 0.9 3 1.8 6 0 m 0 ft 1.8 6 1.8 6 3.6 12 2.7 9 15 4.6 3.6 12 5.4 18 9.2 7.4 5.4 3.6 1.8 0 m 1.8 3.6 5.4 7.4 9.2 3.7 12 5.4 18 7.4 24 9.2 7.4 5.4 3.6 1.8 0 m 1.8 3.6 5.4 7.4 9.2 4.6 15 30 24 18 12 6 0 ft 6 12 18 24 7.4 30 24 30 24 18 12 6 0 ft 6 12 18 24 30 9.2 30 9.2 30 5.5 18 Lens rotates15° to enable adjustment

5.5 18 ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. 4.6 15 LOW VIEW TOP VIEW 3.7 12 SPECIFICATIONS 2.7 9 0 ft 0 m PHYSICAL ELECTRICAL 1.8 6 ENVIRONMENTAL 0.9 3 SIZE: 1.34”H x 2.60”W x 1.18”D OPERATING VOLTAGE: 0 m 0 ft OPERATING TEMP: ( 3.40 cm x 6.65 cm x 2.99 cm ) 12 - 24 VDC 0.9 3 -40º to 160º F (-40º to 71º C) 9SENSOR2.7 WEIGHT: 3 oz CURRENT DRAW: 1.8 6 RELATIVE HUMIDITY: 2.7 9 SENSOR MOUNTING: 5.4 4.6 3.6 2.7 1.8 0.9 0 m 0.9 1.8 2.7 3.6 4.6 5.4 Standard, 4 mA 3.7 12 20 to 90% non-condensing Required 18 15 Hole 12 Size 9 1.125” 6 3 0 ft 3 6 9 12 15 18 DIMMING LOAD: 4.6 15 IP65 RATED: When embedded in Material Thickness 0.25” max Sinks < 20 mA; 5.5 18 wet location luminaire 0-10 VDC LED Drivers / Ballasts ROHS COMPLIANT WIRING DIAGRAM(S): See Figure # 41 on Page 93

ORDERING INFORMATION Specifications subject to change. Example: MSOD 7 ODP BK 2V Series Color Min Dim Level*

MSOD 7 ODP Outdoor Micro Sensor WH White 0V 0 VDC 3V 3 VDC BK Black 1V 1 VDC 4V 4 VDC 2V 2 VDC 5V 5 VDC

*Level after motion time delay expires

www.acuitycontrols.com / 63 PRODUCT INFORMATION Fixture Embedded - Snap-Fit 360° Sensor

Overview Features SNAP-FIT The Snap-Fit sensor is a compact line voltage sensor that • Convenient Snap-in Mounting snaps directly into a small cavity in a fixture. The sensor 360° Sensor • 360º Coverage Pattern utilizes Passive Infrared (PIR) detection to detect motion from occupants within its 360º coverage pattern that overlaps • Self-Contained Relay - No Power Pack Required that of most HID, T-5, or T-8 fixtures used in warehouse • No Minimum Load SNAP-FIT applications. • User Adjustable Time Delay • Push-Button Programmable • Interchangeable Line & Load Wires - Impossible to Wire Backwards • 100 hr Lamp Burn-in Timer • Green LED Status Indicator

COVERAGE PATTERNS

7 Mini-Low Bay 360° Lens 9.2 30 • Recommended for walking motion 7.4 24 SIDE VIEW TOP VIEW 5.4 18 detection from mounting heights 3.6 12 0 ft 0 m between 8 ft (2.44 m) and 20 ft (6.10 m) 1.8 6 • Initial detection of walking motion 0 m 0 ft 1.8 6 along sensor axes at distances of 2x the 15 4.6 3.6 12

mounting height up to 15 ft (4.57 m) and 9.2 7.4 5.4 3.6 1.8 0 m 1.8 3.6 5.4 7.4 9.2 5.4 18 7.4 24 1.75x up to 20 ft (6.10 m) 30 24 18 12 6 0 ft 6 12 18 24 30 9.2 30 • Provides 12 ft (3.66 m) radial detection of small motion when mounted at 9 ft (2.74 m) • Initial detection will occur earlier when 5.5 18 walking across sensor’s field of view than 4.6 15 LOW VIEW TOP VIEW 3.7 12 walking directly at sensor 2.7 9 0 ft 0 m 1.8 6 0.9 3 0 m 0 ft 0.9 3 30 Universal 360° Lens 9 2.7 1.8 6 2.7 9 5.4 4.6 3.6 2.7 1.8 0.9 0 m 0.9 1.8 2.7 3.6 4.6 5.4 3.7 12 SIDE VIEW TOP VIEW • Provides excellent detection of large 18 15 12 9 6 3 0 ft 3 6 9 12 15 18 4.6 15 motion (e.g., walking) when mounted 0 ft 0 m 20 6.1 5.5 18 between 15 to 40 ft (4.57 to 12.19 m) 10 3 10 3 • 15 to 20 ft (4.57 to 6.10 m) radial coverage overlaps area lit by a typical 20 6.1 0 ft 0 m high bay fixture

PRODUCT SELECTION GUIDE SELECTION PRODUCT • Recommended for fixtures that have a 30 9.1 10 3 1:1 spacing to mounting height ratio or less (e.g., fixtures 30’ on center or less @ 40 12.2 20 6.1 6.1 0 m 6.1 a 30’ mounting height). 20 0 ft 20

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SPECIFICATIONS PHYSICAL ELECTRICAL ENVIRONMENTAL

SIZE: 2.25” H x 1.38” W x 0.82” D MAX LOAD: 800 W @ 120 VAC OPERATING TEMP: (5.72 cm x 3.51 cm x 2.08 cm) 1200 W @ 277 VAC 14º to 160º F (-10º to 71º C) WEIGHT: 4 oz 1500 W @ 347 VAC STORAGE TEMP: MOUNTING: Snaps into 2 3/16” H x 1 5/16” W x 1” D MOTOR LOAD: 1/4 HP -14º to 160º F (-26º to 71º C) cavity in fixture FREQUENCY: 50/60 Hz RELATIVE HUMIDITY: Timers are 1.2x for 50 Hz 20 to 90% non-condensing WIRING DIAGRAM(S): See Figure # 39 on Page 93 ROHS COMPLIANT

ORDERING INFORMATION Specifications subject to change. Example: SFR 7 347 LT Series Voltage Temp/Humidity

SFR 7 Snap-Fit Mini-Low Bay (blank) 120/277 VAC (blank) Standard SFR 30 Snap-Fit Universal 347 347 VAC LT Low Temp/High Humidity

64 / www.acuitycontrols.com PRODUCT INFORMATION Fixture Embedded - Snap-Fit Indoor Low Bay & Universal 360° Dimming Sensors

Overview Features The SFD 30 Universal 360º Snap Fit sensor is a compact low • Digital PIR Detection - Excellent RF Immunity SNAP-FIT

voltage sensor that snaps directly into a small cavity in a SNAP-FIT • 0-10 VDC Control Output Indoor Low Bay & Universal 360° fixture. This sensor directly wires to 0-10 VDC dimmable LED drivers and fluorescent ballasts, providing occupancy based • Snap-in Style Embedded Mounting Dimming Sensors high/low dimming control. The SFD 30 provides excellent line • Compatible w/ 0-10 VDC Dimmable Ballasts of sight 360º PIR detection of large motion making it ideal and LED Drivers for small rooms or offices without obstructions or areas with • Adjustable Time Delays primarily walking motion (e.g. corridors, library stacks). For outdoor applications, the SFOD 30 ODP sensor provides both • Programming Button Accessible w/o Opening Sensor Motion and Daylight based control of a 0-10 VDC dimmable • Adjustable Time Delay, Max/Min Dim Levels, outdoor or wet location luminaire. and Ramp Rates The SFD 7 Low Bay Snap Fit sensor is a compact low voltage • No Field Calibration or Sensitivity Adjustments Required sensor that snaps directly into a small cavity in a fixture. This • Non-Volatile Settings Memory sensor directly wires to 0-10 VDC dimmable LED drivers and fluorescent ballasts, providing occupancy based high/low • Convenient Test Mode dimming control. For motion detection, the sensors utilize • Green LED Status Indicator 100% Digital Passive Infrared (PIR) technology that is tuned for walking size motion while preventing false tripping from the environment. For outdoor applications, the SFOD 7 ODP sensor provides both Motion and Daylight based control of a 0-10 VDC dimmable outdoor or wet location luminaire.

COVERAGE PATTERNS

7 Mini-Low Bay 360° Lens 9.2 30 7.4 24 • Recommended for walking motion detection SIDE VIEW TOP VIEW 5.4 18 from mounting heights between 8 ft (2.44 m) 3.6 12 0 ft 0 m and 20 ft (6.10 m) 1.8 6 • Initial detection of walking motion along sensor 0 m 0 ft 1.8 6 axes at distances of 2x the mounting height up 15 4.6 3.6 12 PRODUCT SELECTION GUIDE to 15 ft (4.57 m) and 1.75x up to 20 ft (6.10 m) 9.2 7.4 5.4 3.6 1.8 0 m 1.8 3.6 5.4 7.4 9.2 5.4 18 7.4 24 • Provides 12 ft (3.66 m) radial detection of small 30 24 18 12 6 0 ft 6 12 18 24 30 9.2 30 motion when mounted at 9 ft (2.74 m) • Initial detection will occur earlier when walking across sensor’s field of view than 5.5 18 4.6 15 walking directly at sensor LOW VIEW TOP VIEW 3.7 12 2.7 9 0 ft 0 m 1.8 6 SIDE VIEW TOP VIEW 0.9 3 30 Universal 360° Lens 0 m 0 ft 0 ft 0 m 20 6.1 0.9 3 9 2.7 1.8 6 • Provides excellent detection of large motion 2.7 9 10 3 (e.g., walking) when mounted between 10 3 5.4 4.6 3.6 2.7 1.8 0.9 0 m 0.9 1.8 2.7 3.6 4.6 5.4 3.7 12 15 to 40 ft (4.57 to 12.19 m) 18 15 12 9 6 3 0 ft 3 6 9 12 15 18 4.6 15 5.5 18 20 6.1 0 ft 0 m • 15 to 20 ft (4.57 to 6.10 m) radial coverage

overlaps area lit by a typical high bay fixture 30 9.1 10 3 • Recommended for fixtures that have a 1:1 spacing to mounting height ratio or less (e.g., fixtures 30’ 40 12.2 20 6.1 on center or less @ a 30’ mounting height). 6.1 0 m 6.1 20 0 ft 20

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SPECIFICATIONS PHYSICAL ELECTRICAL ENVIRONMENTAL

SIZE: 2.25” H x 1.38” W x 0.82” D OPERATING VOLTAGE: 12 - 24 VDC OPERATING TEMP: (5.72 cm x 3.51 cm x 2.08 cm) CURRENT DRAW: Standard, 4 mA 14º to 160º F (-10º to 71º C) WEIGHT: 4 oz DIMMING LOAD: Sinks < 20 mA; RELATIVE HUMIDITY: MOUNTING: Snaps into 2 3/16” H x 1 5/16” W x 1” D ~40 ballasts / LED drivers (0-10 VDC) 20 to 90% non-condensing cavity in fixture WIRING DIAGRAM(S): See Figure # 40 on Page 93 ROHS COMPLIANT

ORDERING INFORMATION Specifications subject to change. Example: SFD 30 ADC WH 1V Series Automatic Dimming Control Color Minimum Dim Level 1

SFD 7 Dimming Snap-Fit Mini-Low Bay (blank) None WH White 0V ~0 VDC 3V 3 VDC SFD 30 Dimming Snap-Fit Universal ADC Integrated Dimming Photocontrol 1V 1 VDC 4V 4 VDC 2V 2 VDC 5V 5 VDC Notes 1. Level after occupancy time delay expires

www.acuitycontrols.com / 65 PRODUCT INFORMATION Fixture Embedded - Snap-Fit 360° Outdoor/Wet Location Sensor

Overview Features SNAP-FIT The SFOD xx ODP sensors provide both Motion and Daylight • Digital PIR Detection - Excellent RF Immunity based control of a 0-10 VDC dimmable outdoor or wet location 360º Outdoor/Wet Location Sensor • Integrated Photocontrol luminaire. It can both dim and turn on/off its connected lighting. For motion detection, the sensors utilize Digital • 0-10 VDC Output for Dimming Passive Infrared (PIR) technology that is tuned for walking size • Gasketed Sensor for Outdoor Operation SNAP-FIT motion while preventing false tripping from the environment. • Snap-in Style Embedded Mounting The SFOD xx ODP’s integrated Photocontrol enables additional energy savings during daytime periods when there is • Compatible w/ 0-10 VDC Dimmable Ballasts sufficient daylight. and LED Drivers • Adjustable Time Delays, Max/Min Dim Levels, and Ramp Rates • Programming Button Accessible w/o Opening Sensor or Removing Gasketing for Outdoor/Wet locations • No Field Calibration or Sensitivity Adjustments Required • Non-Volatile Settings Memory • Convenient Test Mode • Green LED Status Indicator

COVERAGE PATTERNS

7 Mini-Low Bay 360° Lens 9.2 30 7.4 24 • Recommended for walking motion SIDE VIEW TOP VIEW 5.4 18 detection from mounting heights 3.6 12 0 ft 0 m between 8 ft (2.44 m) and 20 ft (6.10 m) 1.8 6 0 m 0 ft • Initial detection of walking motion 1.8 6 along sensor axes at distances of 2x the 15 4.6 3.6 12

mounting height up to 15 ft (4.57 m) and 9.2 7.4 5.4 3.6 1.8 0 m 1.8 3.6 5.4 7.4 9.2 5.4 18 7.4 24 1.75x up to 20 ft (6.10 m) 30 24 18 12 6 0 ft 6 12 18 24 30 9.2 30 • Provides 12 ft (3.66 m) radial detection of small motion when mounted at 9 ft (2.74 m) • Initial detection will occur earlier when 5.5 18 4.6 15 walking across sensor’s field of view than LOW VIEW TOP VIEW 3.7 12 walking directly at sensor 2.7 9 0 ft 0 m 1.8 6 0.9 3 0 m 0 ft 0.9 3 Universal 360° Lens 9 2.7 1.8 6 30 2.7 9 5.4 4.6 3.6 2.7 1.8 0.9 0 m 0.9 1.8 2.7 3.6 4.6 5.4 3.7 12 • Provides excellent detection of large SIDE VIEW 18 15 12 9 6 3 0 ft 3 6 9 12 15 18 TOP VIEW 4.6 15 5.5 18 PRODUCT SELECTION GUIDE SELECTION PRODUCT motion (e.g., walking) when mounted 0 ft 0 m 20 6.1 between 15 to 40 ft (4.57 to 12.19 m) • 15 to 20 ft (4.57 to 6.10 m) radial 10 3 10 3 coverage overlaps area lit by a typical high bay fixture 20 6.1 0 ft 0 m • Recommended for fixtures that have a 30 9.1 10 3 1:1 spacing to mounting height ratio or less (e.g., fixtures 30’ on center or less @ 40 12.2 20 6.1 a 30’ mounting height). 6.1 0 m 6.1 20 0 ft 20

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com.

Sequence Of Operation - Motion Sequence Of Operation - Daylight Sequence of Operation For outdoor applications, where safety is of primary concern, To prevent lights from day-burning, the SFOD xx ODP Series When time delay expires, lights ramp down to minimum over 5 min

the SFOD xx ODP Series sensor is factory set to start dimming sensor will dim lighting completely to a ~0 VDC control level MOTION NO MOTION MOTION MAX the lights once the motion time delay expires. Set to 5 min during periods of sufficient daylight. Ideally the SFOD xx ODP B

by default, this time delay is followed by a 5 min ramp down is used with an LED driver that interprets this ~0 VDC control Lights Ramp B period where the lights slowly drop to the minimum dim level. level as an off or sleep mode signal. Providing this type of Pho- Down When Time Delay A Utilizing a long ramp down rate eliminates noticeable drops in tocontrol control eliminates the need for astronomical or time 3 Second LIGHT LEVEL LIGHT Expires Ramp Up light level. If motion is detected at any time during the ramp clocks. Additionally, the sensor’s closed loop Photocontrol A down period or when at the minimum dim level, the sensor adjusts its calibration after every cycle to accommodate visual MIN 5 Min 5 Min Lights @ will quickly ramp the lights back up to maximum level (default changes to the space in which they are installed (for example Time Delay Ramp Down Min Power 100%) over a 3 sec (default) period. This ramp up period is different color cars in a parking garage reflecting light differ- intended to quickly return the lighting to full bright without ently). The Photocontrol operation can also be configured to 0 5 10 15 20 25 30 TIME (mins) distracting occupants with a sudden jump in the space’s light just dim lights to the specified minimum dim level (i.e. the level. The time delays, ramp rates, and max/min dim levels are level used after motion time delay expires) instead of to 0 VDC. user adjustable via the accessible push-button. The default setpoint of the Photocontrol is set to 200 fc so that slight light level changes will not effect operation.

66 / www.acuitycontrols.com PRODUCT INFORMATION Fixture Embedded - Snap-Fit 360° Outdoor/Wet Location Sensor

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SNAP-FIT SPECIFICATIONS PHYSICAL ELECTRICAL ENVIRONMENTAL SIZE: 2.25” H x 1.38” W x 0.82” D OPERATING VOLTAGE: 12 VDC OPERATING TEMP: (5.715 cm x 3.51 cm x 2.08 cm) CURRENT DRAW: Standard, 4 mA -40º to 160º F (-40º to 71º C) WEIGHT: 4 oz. DIMMING LOAD: Sinks < 20 mA; IP65 RATED: When embedded in MOUNTING: Snaps into 2 3/16” H x 1 5/16” W x 1” D 0-10 VDC LED Drivers / Ballasts wet location luminaire cavity in fixture WIRING DIAGRAM(S): See Figure # 40 on Page 93 ROHS COMPLIANT

ORDERING INFORMATION Specifications subject to change. Example: SFOD 7 ODP BK 1V Series Color Min Dim Level 1

SFOD 7 ODP Outdoor Dimming Snap-Fit Mini-Low Bay WH White 0V 0 VDC SFOD 30 ODP Outdoor Dimming Snap-Fit Universal BK Black 1V 1 VDC 2V 2 VDC 3V 3 VDC 4V 4 VDC 5V 5 VDC Notes 1. Level after occupancy time delay expires PRODUCT SELECTION GUIDE

www.acuitycontrols.com / 67 PRODUCT INFORMATION Fixture Embedded - Snap-Fit Daylight Sensor

Overview Features SNAP-FIT The SFD ADC Series Automatic Dimming Control Photocontrol • Automatically Dims 0-10 VDC Ballasts/Drivers Low Voltage Daylight Sensor sensor provides continuous dimming control of 0-10 VDC as Daylight Changes dimmable ballasts or LED drivers for daylight harvesting • Auto Set-Point Calibration Mode applications. Ideal for spaces with windows like classrooms, vestibules, corridors, offices, or bathrooms; the SFD ADC • Digital Set-Point Control SNAP-FIT works to maintain a constant overall room lighting level by • Adjustable High & Low Trim controlling the connected 0-10 VDC dimmable ballast / LED • Push-Button Programmable driver(s) to increase or decrease their fixtures’ light output level accordingly. The SFD ADC snap fit sensor is is designed • 100 hr Lamp Burn-in Timer to be easily embedded into luminaires. The SFD 7 sensor • Green LED Status Indicator is recommended for indoor motion control. For outdoor applications, the SFOD 7 ODP sensor provides both Motion and Daylight based control of a 0-10 VDC dimmable outdoor or wet location luminaire.

SOLUTION TYPES / KEY LIGHTS FULL ON LIGHTS OFF LIGHTS FULL DIM

ADC / KEY Automatic Dimming Control LIGHTS FULL ON LIGHTS OFF LIGHTS FULL DIM

PC ADC PC ADC AMPLE DAYLIGHT AMPLE DAYLIGHT AMPLE DAYLIGHT PC ADC PC ADC DEADBAND

DIMMING DIMMING AMPLE DAYLIGHT AMPLE DAYLIGHT AMPLE DAYLIGHT RANGE RANGE DEADBAND DIMMING DIMMING

SET-POINT SET-POINT SET-POINT RANGE RANGE

SET-POINT SET-POINT SET-POINT NO DAYLIGHT NO DAYLIGHT NO DAYLIGHT

NO DAYLIGHT NO DAYLIGHT NO DAYLIGHT

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SPECIFICATIONS PRODUCT SELECTION GUIDE SELECTION PRODUCT PHYSICAL ELECTRICAL ENVIRONMENTAL

SIZE: 2.25” H x 1.38” W x 0.82” D OPERATING VOLTAGE: 12 VDC OPERATING TEMP: (5.715 cm x 3.51 cm x 2.08 cm) CURRENT DRAW: Standard, 4 mA -40º to 160º F (-40º to 71º C) WEIGHT: 4 oz DIMMING LOAD: Sinks < 20 mA; RELATIVE HUMIDITY: MOUNTING: Snaps into 2 3/16” H x 1 5/16” W x 1” D 0-10 VDC LED Drivers / Ballasts 20 TO 75% Non-Condensing cavity in fixture WIRING DIAGRAM(S): See Figure # 40 on Page 93 ROHS COMPLIANT

ORDERING INFORMATION Specifications subject to change. Example: SFD ADC WH 3V Series Min Dim Level

SFD ADC WH Daylight Dimming Snap-Fit 0V 0 VDC 1V 1 VDC 2V 2 VDC 3V 3 VDC 4V 4 VDC 5V 5 VDC

68 / www.acuitycontrols.com PRODUCT INFORMATION Fixture Embedded - Small Box Sensors

Overview LampMaximizer® Technology The Small Box (SB) Series utilizes an enclosure that can be • Protects Lamp Life while Maximizing Energy Savings EMBEDDED EMBEDDED internally mounted in lighting fixtures. SB series sensors • Minimum On Timer (15 min default) Small Box Sensors accommodate several lens types, can utilize Passive Infrared • Occupancy Time Delay (10 min default) (PIR) or Dual Technology (PDT) detection, and can be low or line voltage (Single or 2-Pole). • LampMaximizer+ Mode - Optimizes Lamp Life & Energy Savings (disabled by default) Features • Switch Counter (in 1000’s) • Digital PIR Detection - Excellent RF Immunity • Total Lamp On Time (in khrs) • User Adjustable Time Delays • Push-Button Programmable • Convenient Test Mode • 100 hr Lamp Burn-in Timer • Green LED Status Indicator

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SPECIFICATIONS PHYSICAL ELECTRICAL - LOW VOLTAGE ELECTRICAL - LINE VOLTAGE ENVIRONMENTAL

SIZE: (w/ mounting flange) OPERATING VOLTAGE: MAX LOAD / POLE: OPERATING TEMP: 3.40” H x 3.40” W x 1.40” D 12-24 VAC/VDC 800 W @ 120 VAC 14º to 160º F (-10º to 71º C) (8.64 cm x 8.64 cm x 3.56 cm) RECOMMENDED POWER PACK: 1200 W @ 277 VAC STORAGE TEMP: WEIGHT: 6 oz PP20 1500 W @ 347 VAC -14º to 160º F (-26º to 71º C) MOUNTING: 2.65” square opening in CURRENT DRAW: 5 Amps @ 208/240 VAC RELATIVE HUMIDITY: fixture (minimum depth 1.50”) Standard, 4 mA 5 Amps @ 480 VAC 20 to 90% non-condensing w/ R option, 16 mA MOTOR LOAD: 1/4 HP ROHS COMPLIANT DIMMING LOAD: FREQUENCY: 50/60 Hz Sinks < 20mA; DIMMING LOAD: ~40 Ballasts @ .5mA each Sinks < 20mA; WIRING DIAGRAM(S): ~40 Ballasts @ .5 mA each See Figure # 8 on Page 84 WIRING DIAGRAM(S): (without relay option) See Figure # 9 on Page 84 PRODUCT SELECTION GUIDE & # 42 on Page 93

KEY SPECS SERIES LENS TYPE DETECTION POWER TYPE OPTIONS SB 9 STANDARD RANGE 360° PIR 12-24 VDC/VAC R, D, P, ADC, LT SB PDT 9 STANDARD RANGE 360° PDT 12-24 VDC/VAC R, D, P, ADC, LT SBR 9 STANDARD RANGE 360° PIR 120/277 VAC D, P, ADC, 347, LT SBR PDT 9 STANDARD RANGE 360° PDT 120/277 VAC D, P, ADC, 347, LT SBR 9 2P STANDARD RANGE 360° PIR 120/277 VAC / Pole P, DZ, 347, LT SBR PDT 9 2P* STANDARD RANGE 360° PDT 120/277 VAC / Pole P, DZ, 347, LT SB 10 EXTENDED RANGE 360° PIR 12-24 VDC/VAC R, D, P, ADC, LT SB PDT 10 EXTENDED RANGE 360° PDT 12-24 VDC/VAC R, D, P, ADC, LT SBR 10 EXTENDED RANGE 360° PIR 120/277 VAC D, P, ADC, 347, LT SBR PDT 10 EXTENDED RANGE 360° PDT 120/277 VAC D, P, ADC, 347, LT SBR 10 2P* EXTENDED RANGE 360° PIR 120/277 VAC / Pole P, DZ, 347, LT SBR PDT 10 2P* EXTENDED RANGE 360° PDT 120/277 VAC / Pole P, DZ, 347, LT SB 6 HIGH BAY 360° PIR 12-24 VDC/VAC R, P, D, LT SBR 6 HIGH BAY 360° PIR 120/277 VAC D, P, 347, LT SBR 6 2P* HIGH BAY 360° PIR 120/277 VAC / Pole P, 347, LT SB 50 HIGH BAY AISLEWAY PIR 12-24 VDC/VAC R, D, LT SBR 50 HIGH BAY AISLEWAY PIR 120/277 VAC D, 347, LT SBR 50 2P* HIGH BAY AISLEWAY PIR 120/277 VAC / Pole 347, LT

* LampMaximizer+ features not available Note: For detailed option descriptions see page corresponding to Recessed Mount (RM) version of each SB Series sensor

ORDERING INFORMATION Specifications subject to change. Example: SB 10 D LT Series Options

See Above Key Specs See Above Key Specs

www.acuitycontrols.com / 69 PRODUCT INFORMATION Fixture Embedded - Small Box Outdoor/Wet Location Sensors

Overview Features EMBEDDED The SBGR PC Series of on/off outdoor rated Photocontrol • Auto Set-Point Calibration Mode Outdoor Small Box Photocontrol Sensors sensors provides intelligent control of lighting for daylight • Compatible w/ LEDs, Electronic & Magnetic Ballasts, harvesting applications. Designed to recess mount into a CFLs, & Incandescents 2.65” (6.73 cm) square opening in a fixture, the sensors work • Self-Contained Relay(s), No Power Pack Needed by monitoring daylight conditions, then controlling conected lighting so as to insure that adequate lighting levels are • Gasketed for use in Wet Location Luminaire EMBEDDED maintained. The SBGR PC provides on/off style Photocontrol • Digital Set-Point Control control; turning off the lights when sufficient daylight is • Interchangeable Hot & Load Wires, Impossible to present and turning them on when additional lighting is Wire in Reverse necessary. The SBGR PC Series sensors are line powered and • Push-Button Programmable can switch loads directly without the need for a power pack. • Adjustable Transition Delays • 100 hr Lamp Burn-in Timer • Green LED Status Indicator

OPTION INFORMATION SOLUTION TYPES / KEY LIGHTS FULL ON LIGHTS OFF LIGHTS FULL DIM

DZ HVOLT PC Dual Zone 347 - 480 VAC Automatic On/Off Switching • Provide second output that can control an additional • Allows sensor to be powered from and switch zone of lighting 347-480 VAC PC ADC PC ADC Stepped Dimming (Duo) Operation (PC Only) AMPLE DAYLIGHT AMPLE DAYLIGHT AMPLE DAYLIGHT • Ideal for A/B (also called inboard/outboard) switching applications DEADBAND DIMMING DIMMING • Determines the necessary on/off combination of the two RANGE RANGE poles in order to maintain adequate lighting

Percentage Offset Operation SET-POINT SET-POINT SET-POINT • Ideal for classrooms with individually controlled parallel rows of lights • PC sensors use a relative set-point for the second pole NO DAYLIGHT NO DAYLIGHT NO DAYLIGHT that is a percentage of the first pole’s set-point

/ KEY LIGHTS FULL ON LIGHTS OFF LIGHTS FULL DIM

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. PC ADC PC ADC PRODUCT SELECTION GUIDE SELECTION PRODUCT SPECIFICATIONS PHYSICAL ELECTRICAL AMPLE DAYLIGHT ENVIRONMENTALAMPLE DAYLIGHT AMPLE DAYLIGHT SIZE: (w/ MOUNTING FLANGE) MAXIMUM LOAD: OPERATING TEMP: 3.40” H x 3.40” W x 1.40” D 800 W @ 120 VAC 14º to 160º F (-10º to 71º C) DEADBAND DIMMING DIMMING

(8.64 cm x 8.64 cm x 3.56 cm) 1200 W @ 277 VAC IP65 RATED: When RANGE embedded in RANGE WEIGHT: 6 oz 1500 W @ 347 VAC wet location luminaire MOUNTING: 2.65” (6.73 cm) square opening MINIMUM LOAD: None ROHS COMPLIANT in fixture (minimum depth MOTOR LOAD: 1/4 HP SET-POINT SET-POINT SET-POINT 1.50” (3.8 cm) FREQUENCY: 50/60 Hz DIMMING LOAD: Sinks < 20mA; ~40 Ballasts @ .5 mA each NO DAYLIGHT NO DAYLIGHT NO DAYLIGHT WIRING DIAGRAM(S): See Figure # 39 on Page 93

ORDERING INFORMATION Specifications subject to change. Example: SBGR PC DZ WH Series Dual Zone 1 Voltage Color

SBGR PC Embedded Small Box Photocontrol (blank) Single Zone (blank) 120/277 VAC WH White DZ Dual Zone HVOLT 347 - 480 VAC BK Black

Notes 1. Not available with HVOLT

70 / www.acuitycontrols.com PRODUCT INFORMATION Fixture Embedded - Small Box Outdoor/Wet Location Sensors

Overview LampMaximizer® Technology The Small Box (SB) Series utilizes an enclosure that can be • Protects Lamp Life while Maximizing Energy Savings EMBEDDED EMBEDDED internally mounted in lighting fixtures. SB series sensors • Minimum On Timer (15 min default) Small Box Sensors accommodate several lens types, can utilize Passive Infrared • Occupancy Time Delay (10 min default) (PIR) or Dual Technology (PDT) detection, and can be low or line voltage (Single or 2-Pole). • LampMaximizer+ Mode - Optimizes Lamp Life & Energy Savings (disabled by default) Features • Switch Counter (in 1000’s) • Digital PIR Detection - Excellent RF Immunity • Total Lamp On Time (in khrs) • User Adjustable Time Delays • Not available with OEX option • Push-Button Programmable • Convenient Test Mode • 100 hr Lamp Burn-in Timer • Green LED Status Indicator

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SPECIFICATIONS PHYSICAL ELECTRICAL - LINE VOLTAGE - SINGLE POLE ELECTRICAL - LINE VOLTAGE - 2 POLE ENVIRONMENTAL

SIZE: (w/ mounting flange) MAX LOAD / POLE: MAX LOAD / POLE: (1 Phase Only) OPERATING TEMP: 3.40” H x 3.40” W x 1.40” D 800 W @ 120 VAC 800 W @ 120 VAC 14º to 160º F (-10º to 71º C) (8.64 cm x 8.64 cm x 3.56 cm) 1000 W @ 208 VAC 1200 W @ 277 VAC RELATIVE HUMIDITY: WEIGHT: 6 oz 1200 W @ 240 VAC 1500 W @ 347 VAC 20 to 90% non-condensing MOUNTING: 2.65” square opening in fixture 1200 W @ 277 VAC MOTOR LOAD: 1/4 HP IP65 RATED: When embedded in minimum depth 1.50”(3.8 cm) 1500 W @ 347 VAC FREQUENCY: 50/60 Hz wet location luminaire 2160 W @ 480 VAC WIRING DIAGRAM(S): ROHS COMPLIANT MOTOR LOAD: 1/4 HP See Figure # 42 on Page 93 FREQUENCY: 50/60 Hz DIMMING LOAD: Sinks < 20mA; (0-10 VDC LED Drivers / Ballasts) WIRING DIAGRAM(S):

See Figure # 9 on Page 84 PRODUCT SELECTION GUIDE

KEY SPECS SERIES COVERAGE PATTERN DETECTION POWER TYPE SBGR 9 STANDARD RANGE 360° PIR 120/277 VAC SBGR 9 2P STANDARD RANGE 360° PIR 120/277 VAC / Pole SBGR PDT 9 STANDARD RANGE 360° PDT 120/277 VAC SBGR 10 EXTENDED RANGE 360° PIR 120/277 VAC SBGR 10 2P EXTENDED RANGE 360° PIR 120/277 VAC / Pole SBGR PDT 10 EXTENDED RANGE 360° PDT 120/277 VAC SBGR 6 HIGH BAY 360° PIR 120/277 VAC SBGR 6 2P HIGH BAY 360° PIR 120/277 VAC / Pole

ORDERING INFORMATION Specifications subject to change. Example: SBGR 9 OEX WH Series Detection Type Dimming/Photocontrol Voltage Color Minimum Dim Level 3

SBGR 6 (Blank) Indoor PIR (Blank) None (Blank) 120/277 VAC WH White 0V 0 VDC SBGR 9 OEX1 Outdoor PIR D Occupancy Controlled High/Low Dimming HVOLT 347-480 VAC BK Black 1V 1 VDC SBGR PDT 9 P Photocontrol 2V 2 VDC SBGR 10 ADC2 Photocontrol with Dimming 3V 3 VDC SBGR PDT 10 4V 4 VDC 5V 5 VDC Notes 1. Not available with Passive Dual Technology (PDT) 2. Not available with Outdoor PIR (OEX) 3. Required for D option

ORDERING INFORMATION Specifications subject to change. Example: SBGR 6 2P OEX WH Series Detection Type Dimming/Photocontrol Voltage Color

SBGR 6 2P (Blank) Indoor PIR (Blank) None (Blank) 120/277 VAC WH White SBGR 9 2P OEX Outdoor PIR P Photocontrol 347 347 VAC BK Black SBGR 10 2P DZ Dual Zone Photocontrol

www.acuitycontrols.com / 71 PRODUCT INFORMATION Fixture Embedded - Small Box Outdoor/Wet Location Sensors

Overview LampMaximizer® Technology EMBEDDED The SBG xx Series outdoor rated sensor provides 360º • Protects Lamp Life while Maximizing Energy Savings Small Box Sensors Passive Infrared motion detection. The SBG xx sensor recess • Minimum On Timer (15 min default) mounts into a 2.65” (6.7 cm) square opening in a wet location • Occ. Time Delay (10 min default) luminaire. The unit’s optional integrated Photocontrol enables additional energy savings during daytime periods when there • LampMaximizer+ Mode - Optimizes Lamp Life & Energy is sufficient daylight. Savings (disabled by default) EMBEDDED Features • Switch Counter (in 1000’s) • Digital PIR Detection - Excellent RF Immunity • Total Lamp On Time (in khrs) • Gasketed for use in a Wet Location Luminaire • Not available with OEX option • Push-Button Programmable • Non-Volatile Settings Memory • Adjustable Time Delays • Convenient Test Mode • Optional 0-10 VDC Dimming Output • Green LED Status Indicator

OPTION INFORMATION

OEX D P Outdoor PIR Occupancy Controlled Dimming Photocontrol • Adjusts PIR for outdoor motion detection • Provides dimming outputs to control 0-10 VDC • Auto Set-point calibration dimmable ballasts • Eliminates false ons caused by environmental factors • On/off mode: Full on/off control of lighting during (e.g. wind) • Provides a second occupancy timeout period that enables periods of occupancy with adequate daylight the lights to go to a dim setting before turning off • Inhibit mode: Prevents lights from turning on if adequate • Adjustable max/min dim setting daylight is available, but does not turn lights off

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SPECIFICATIONS PHYSICAL ELECTRICAL ENVIRONMENTAL

SIZE: (w/ MOUNTING FLANGE) OPERATING VOLTAGE: OPERATING TEMP: 3.40” H x 3.40” W x 1.40” D 12-24 VAC/VDC -40º to 160º F (-40º to 71º C) PRODUCT SELECTION GUIDE SELECTION PRODUCT (8.64 cm x 8.64 cm x 3.56 cm) CURRENT DRAW: 4 mA IP65 RATED: When embedded in WEIGHT: 6 oz RECOMMENDED POWER PACK: wet location luminaire MOUNTING: 2.65” (6.73 cm) square opening PP20 or MP20 ROHS COMPLIANT in fixture (minimum depth DIMMING LOAD: Sinks < 20 mA 1.50” (3.8 cm) (0-10 VDC LED Drivers / Ballasts) WIRING DIAGRAM(S): See Figure # 8 on Page 84 (without relay option)

ORDERING INFORMATION Specifications subject to change. Example: SBG 6 OEX D WH 1V Series Detection Type Dimming / Photocontrol 1 Color Minimum Dim Level 2

SBG 6 (blank) Indoor PIR (blank) None WH White 0V 0 VDC SBG 10 OEX Outdoor PIR D Occupancy Controlled High/Low Dimming BK Black 1V 1 VDC P Photocontrol 2V 2 VDC 3V 3 VDC 4V 4 VDC 5V 5 VDC Notes 1. Dimming & Photocontrol not available together in this model family, see SBG xx ODP datasheet for alternate solution 2. Required for D option

72 / www.acuitycontrols.com PRODUCT INFORMATION Fixture Embedded - Small Box Outdoor/Wet Location Sensors

Overview The SBGR xx ODP Series sensors provide both Motion and Daylight based control of a 0-10 VDC dimmable outdoor or wet location EMBEDDED EMBEDDED luminaire. The SBGR xx ODP can both switch and dim its connected lighting. For motion detection, the sensor utilizes 100% Digital Small Box Sensors Passive Infrared (PIR) technology that is tuned for walking size motion while preventing false tripping from the environment. The unit’s integrated Photocontrol enables additional energy savings during daytime periods when there is sufficient daylight. Features • Digital PIR Detection - Excellent RF Immunity • Adjustable Time Delays, Max/Min Dim Levels, and Ramp Rates • Integrated Photocontrol • Programming Button Accessible w/o Opening Sensor • Self-Contained Relay for Switching or Removing Gaskets • 0-10 VDC Output for Dimming • No Field Calibration or Sensitivity Adjustments Required • Gasketed for use in Wet Location Luminaire • Non-Volatile Settings Memory • Compatible w/ 0-10 VDC Dimmable Ballasts • Convenient Test Mode and LED Drivers • Green LED Status Indicator • Interchangeable Hot & Load Wires, Impossible to Wire in Reverse

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com.

Sequence Of Operation - Motion Sequence Of Operation - Daylight Sequence of Operation For outdoor applications, where occupant safety is of primary To prevent lights from day-burning, the SBGR xx ODP When time delay expires, lights ramp down to minimum over 5 min concern, the SBGR xx ODP Series sensors are factory set Series sensor will switch lighting completely off during MOTION NO MOTION MOTION MAX to start dimming the lights once the motion time delay periods of sufficient daylight. Providing on/off Photocontrol B expires. Set to 5 min by default, this time delay is followed control eliminates the need for astronomical or time clocks. Lights Ramp B Down When by a 5 min ramp down period where the lights slowly drop Additionally, the sensor’s closed loop Photocontrol adjusts its Time Delay A 3 Second to the minimum dim level. Utilizing a long ramp down calibration after every cycle to accommodate visual changes LEVEL LIGHT Expires Ramp Up rate eliminates noticeable drops in light level. If motion is to the space in which they are installed (for example different A MIN detected at any time during the ramp down period or when color cars in a parking garage reflecting light differently). The 5 Min 5 Min Lights @ at the minimum dim level, the sensor will quickly ramp the Photocontrol operation can also be set to dim lights to the Time Delay Ramp Down Min Power lights back up to maximum level (default 100%) over a 3 sec minimum level instead of turning them off. 0 5 10 15 20 25 30 PRODUCT SELECTION GUIDE (default) period. This ramp up period is intended to quickly TIME (mins) return the lighting to full bright without distracting occupants with a sudden jump in the space’s light level. The time delays, ramp rates, and max/min dim levels are user adjustable via the accessible push-button. See luminaire specifications for corresponding power level at minimum dim level.

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. SPECIFICATIONS PHYSICAL ELECTRICAL ENVIRONMENTAL

SIZE: (w/ MOUNTING FLANGE) OPERATING VOLTAGE: OPERATING TEMP: 3.40” H x 3.40” W x 1.40” D 12-24 VAC/VDC -40º to 160º F (-40º to 71º C) (8.64 cm x 8.64 cm x 3.56 cm) CURRENT DRAW: 4 mA IP65 RATED: When embedded in WEIGHT: 6 oz RECOMMENDED POWER PACK: wet location luminaire MOUNTING: 2.65” (6.73 cm) square opening PP20 or MP20 ROHS COMPLIANT in fixture (minimum depth DIMMING LOAD: Sinks < 20 mA 1.50” (3.8 cm) (0-10 VDC LED Drivers / Ballasts) WIRING DIAGRAM(S): See Figure # 9 on Page 84

ORDERING INFORMATION Specifications subject to change. Example: SBGR 6 ODP WH 3V Series Voltage Color Minimum Dim Level

SBGR 6 ODP (blank) 120/277 VAC (MVOLT) WH White 0V 0 VDC SBGR 10 ODP HVOLT 347 - 480 VAC BK Black 1V 1 VDC 2V 2 VDC 3V 3 VDC 4V 4 VDC 5V 5 VDC

www.acuitycontrols.com / 73 74 / www.acuitycontrols.com SPECIALTY PRODUCTS

76 DATALOGGER

78 WIRE GUARDS

79 MASKING LABELS

79 BALLAST DISCRIMINATOR

www.acuitycontrols.com / 75 PRODUCT INFORMATION Data Logger

Overview Setting New Standards in Monitoring DATA LOGGER The Data Logger Monitoring System models facility lighting Much like our occupancy sensors, Sensor Switch’s Data Monitoring System and occupancy patterns. Primarily used to quantify potential Logger Monitoring System utilizes innovative technology, energy savings from occupancy sensor projects, this powerful surpassing all similar systems available. Its features are tool is essential for performance contractors, lighting both unique and necessary to perform thorough ROI and retrofitters, and facility managers when calculating Return on payback analysis. Data Loggers units can be leased on a Investment (ROI) and payback estimates. per project basis at no charge, or purchased by qualified

DATA LOGGER DATA customers. Subscription access to the Data Logger Software Analysis Suite is also available to customers in good standing and at no charge. To request or purchase Data Loggers, contact your local Acuity Brands sales representative or email: [email protected].

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com.

Device Features Hours per Week for Each Area Type While light monitors have been around for years, the Data Logger surpasses all predecessors with several new easy-to-use features that assure more useful results. 150 • Combination occupancy sensor & light monitoring device • Distinguishes between natural and artificial light sources • Multiple loggers can be used together to monitor large spaces 75 • Installs in seconds; push-button operation • Data points are recorded every two minutes

Energy Savings Analysis The Data Logger’s information is downloaded into 0 sophisticated software that analyzes the data and PO M OS R S H generates customized reports.

PRODUCT SELECTION GUIDE SELECTION PRODUCT • Each Data Logger is assigned an Area Type • Software averages information from Data Loggers of similar Area Types • “Lights On vs. Occupancy” activity per area presented in 24 hour timelines • Total energy usage calculated from user-entered lighting loads • User-adjustable “virtual” occupancy sensor time delay settings • Analysis of “Savings vs. Time Delay Setting” on sensors

76 / www.acuitycontrols.com PRODUCT INFORMATION Data Logger

ADDITIONAL INFORMATION For additional product information, visit www.acuitycontrols.com. DATA LOGGER

System Highlights • Data Logger units record activity of a building’s lighting,

as well as its occupants Sun: 1.25.2009 2AM 3 AM 4 AM 5 AM 6 AM 7 AM 8 AM 9 AM 10 AM 11 AM noon 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11PM • 2AMData Logger 3 AM software 4 AM analyzes 5 informationAM 6 AM and 7 AM 8 AM 9 AM 10 AM 1 AM noon 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11PM

generates customized reports Mon: 1.26.2009 2AM 3 AM 4 AM 5 AM 6 AM 7 AM 8 AM 9 AM 10 AM 11 AM noon 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11PM • Customized reports quantify potential energy savings 6AM 3 AM 4 AM 5 AM 6 AM 7 AM 8 AM 9 AM 10 AM 1 AM noon 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11PM from occupancy Tue: 1.27.2009 2AM 3 AM 4 AM 5 AM 6 AM 7 AM 8 AM 9 AM 10 AM 11 AM noon 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11PM • Data is presented in “Lights On vs. Occupancy” timeline

• Customized reports quantify potential energy savings Wed: 1.28.2009 2AM 3 AM 4 AM 5 AM 6 AM 7 AM 8 AM 9 AM 10 AM 11 AM noon 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11PM from occupancy sensor projects

• Use of system is provided to qualified customers at no Thur: 1.29.2009 2AM 3 AM 4 AM 5 AM 6 AM 7 AM 8 AM 9 AM 10 AM 11 AM noon 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11PM 2AMcharge 3 AM 4 AM 5 AM 6 AM 7 AM 8 AM 9 AM 10 AM 1 AM noon 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11PM

Fri: 1.30.2009 2AM 3 AM 4 AM 5 AM 6 AM 7 AM 8 AM 9 AM 10 AM 11 AM noon 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11PM

Sat: 1.31.2009 2AM 3 AM 4 AM 5 AM 6 AM 7 AM 8 AM 9 AM 10 AM 11 AM noon 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11PM 2AM 3 AM 4 AM 5 AM 6 AM 7 AM 8 AM 9 AM 10 AM 1 AM noon 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11PM

Red lines represent time intervals White bars represent when the lights are on

Yellow lines represent peak billing hours Black bars represent occupancy in the room PRODUCT SELECTION GUIDE

Customized Reports Area Type Averages Normalized Weekly Lights On Normalized Weekly Occupied • Savings calculated using up to 4 Time-of-Day Billing Rates Area Type Qty Watts Peak O Shldr1 Shldr2 Total Peak O Shldr1 Shldr2 Total % sav Private Oce PO 2 320 26.88 20.87 0.00 0.00 47.76 22.76 3.61 0.00 0.00 26.37 44.79% • Total potential savings summaries presented in Meeting Room M 3 1387 33.75 59.12 0.00 0.00 92.88 21.95 22.14 0.00 0.00 44.09 52.53% easy-to-read charts & graphs Open Space OS 2 10600 39.99 70.45 0.00 0.00 110.44 39.96 45.12 0.00 0.00 85.08 22.96% Restroom R 3 213 30.62 87.56 0.00 0.00 118.18 20.90 17.65 0.00 0.00 38.55 67.38% Storage S 2 240 5.33 15.52 0.00 0.00 20.85 0.78 7.27 0.00 0.00 8.04 61.44% Hallway H 2 880 39.62 98.08 0.00 0.00 137.70 26.32 27.66 0.00 0.00 53.98 60.80% Building Average 28880 37.99 68.87 0.00 106.86 35.08 38.59 0.00 73.67 31.06%

ORDERING INFORMATION Specifications subject to change. Example: LQDM 6 KIT Model#

LQDM 6 KIT Kit containing: 45 data logger devices, 1 hard sided carrying case, 3M double sided tape strips, field monitoring forms, DL6 Software Guide and Installation Guidelines

www.acuitycontrols.com / 77 PRODUCT INFORMATION Occupancy Sensor Wire Guards

Overview Features WIRE GUARDS These super tough wire guards are extremely effective in • 9-Gauge Coated Steel Wire reducing malfunctions and high maintenance costs in areas for Occupancy Sensors • Easy Installation and Removal where abuse is severe. These units are cages constructed of sturdy 9-gauge steel wire coated with heavy duty polyester. • Paintable These durable, easy-to-install devices help prevent vandalism • CSFM and MEA approved and accidental damage without significantly effecting the

ACCESSORIES sensor’s view pattern or coverage range. • UL Listed • LED Status Indicator on Sensor Remains Visible

SPECIFICATIONS PHYSICAL CEILING WIRE GUARD SIZE: 7.00” Diameter, 3.25” High WALL WIRE GUARD SIZE: 4.00”W x 6.25”H x 2.25”D CORNER WIRE GUARD SIZE: 5.38”W x 7.75”H x 5.63”D WG1 WG2 BRACKET WIRE GUARD SIZE: 8.00”W x 8.00”H x 8.00”D

WG3 WG4

PRODUCT SELECTION GUIDE SELECTION PRODUCT ORDERING INFORMATION Specifications subject to change. Example: WG1 Model#

WG1 Ceiling Mounted Sensor Wire Guard WG2 Wall Mounted Sensor Wire Guard WG3 Corner Mounted Sensor Wire Guard WG4 Bracket Mounted Sensor Wire Guard

78 / www.acuitycontrols.com PRODUCT INFORMATION High Bay 360° Masking Labels

Overview

These labels (included) enable masking off a portion of the view pattern for end-of-aisle applica- MASKING LABELS ACCESSORIES tions or trimming the sensor’s side viewing to create a rectangular pattern for center-of-aisle High Bay 360° & viewing only. High Bay Bi-directional Aisleway Note: Masking labels not included with wet location sensors

PRODUCT INFORMATION Ballast Discriminator

Overview The BD1 Ballast Discriminator is the ideal tool to quickly determine your retrofit opportunities by distin- BALLAST guishing between magnetic and electronic ballasts. Simply point the discriminator at the light fixture, then press and hold the button until the LED lights. If the LED lights green, the ballast is electronic; if the DISCRIMINATOR LED lights orange, the ballast is magnetic. A must for every lighting retrofitter. PRODUCT SELECTION GUIDE

ORDERING INFORMATION Specifications subject to change. Example: BD1 Model#

BD1 Ballast Discriminator - Handheld Tool

www.acuitycontrols.com / 79

WIRING DIAGRAMS

82 WALL SWITCH OCCUPANCY SENSORS

84 CEILING MOUNT OCCUPANCY SENSORS

86 WALL MOUNT OCCUPANCY SENSORS

87 FIXTURE MOUNT OCCUPANCY SENSORS

88 DAYLIGHT CONTROL OCCUPANCY SENSORS

90 POWER PACKS & SECONDARY PACKS

91 SPECIALTY POWER PACKS

92 WALLPODS

93 EMBEDDED OCCUPANCY SENSORS

www.acuitycontrols.com / 81 WALL SWITCH OCCUPANCY SENSORS

FIG. 1 FIG. 2 WALL SWITCH – 1-POLE NEUTRAL/GROUND WALL SWITCH – 1-POLE GROUND WALL SWITCH OCCUPANCY SENSORS OCCUPANCY SWITCH WALL

FIG. 3 WALL SWITCH – 2-POLE NEUTRAL/GROUND WIRING DIAGRAMS

FIG. 4 WALL SWITCH – 2-POLE GROUND

82 / www.acuitycontrols.com WALL SWITCH OCCUPANCY SENSORS WIRING DIAGRAMS www.acuitycontrols.com / 83 www.acuitycontrols.com BLK - 120 V - 120 BLK V ORN - 277 PP20 - RELAY OPTION R - RELAY WALL SWITCHES: LOW VOLTAGE LOW SWITCHES: WALL FIG. 7 FIG. 6 PRESET TIMER SWITCH FIG. 5 SSD 120 CEILING MOUNT OCCUPANCY SENSORS

FIG. 8 LOW VOLTAGE STANDARD & EXTENDED RANGE SENSORS

CEILING MOUNT OCCUPANCY SENSORS OCCUPANCY CEILING MOUNT BLK - 120 V PP20 ORN - 277 V

R - RELAY OPTION

D, P, ADC - PHOTOCELL / DIMMING OPTIONS

FIG. 9 LINE VOLTAGE STANDARD & EXTENDED RANGE SENSORS WIRING DIAGRAMS

D, ADC - DIMMING OPTIONS

FIG. 10 LINE VOLTAGE 2-POLE STANDARD RANGE, EXTENDED RANGE, & HIGH BAY SENSORS

84 / www.acuitycontrols.com CEILING MOUNT OCCUPANCY SENSORS WIRING DIAGRAMS www.acuitycontrols.com / 85 www.acuitycontrols.com * Applies only to CMR/CMRB occupancy only to * Applies sensors. BLK - 120 V - 120 BLK V ORN - 277 - PHOTOCELL / DIMMING OPTIONS - PHOTOCELL D, P PP20 * - RELAY OPTION R - RELAY LINE VOLTAGE 208/240, or 480 VAC HIGH BAY SENSORS BAY HIGH 480 or VAC 208/240, VOLTAGE LINE FIG. 13 FIG. 12 & FIXTURE RECESSED MOUNT SENSORS CEILING, BAY HIGH VOLTAGE LINE FIG. 11 & FIXTURE CEILING MOUNT SENSORS VOLTAGE LOW WALL MOUNT OCCUPANCY SENSORS

FIG. 14 LOW VOLTAGE WIDE VIEW & HALLWAY SENSORS

BLK - 120 V WALL MOUNT OCCUPANCY SENSORS OCCUPANCY MOUNT WALL PP20 ORN - 277 V R - RELAY OPTION

P - PHOTOCELL OPTION

FIG. 15 LINE VOLTAGE WIDE VIEW & LARGE AREA WALL SWITCH SENSORS: SINGLE POLE WIRING DIAGRAMS

FIG. 16 LINE VOLTAGE WIDE VIEW & LARGE AREA WALL SWITCH SENSORS: 2-POLE

FIG. 17 LINE VOLTAGE HALLWAY SENSORS

86 / www.acuitycontrols.com FIXTURE MOUNT OCCUPANCY SENSORS WIRING DIAGRAMS www.acuitycontrols.com / 87 www.acuitycontrols.com or Load 2 Load Load 1 Load Load 1 Load 2 Load FIXTURE BALLAST LED DRIVER or or LED DRIVER or LED DRIVER or LED DRIVER or LED DRIVER FIXTURE BALLAST FIXTURE BALLAST FIXTURE BALLAST FIXTURE BALLAST FIXTURE BALLAST LED DRIVER

LINE VOLTAGE INTERCHANGEABLE LENS FIXTURE MOUNT: 2-PHASE INTERCHANGEABLE FIXTURE LENS MOUNT: VOLTAGE LINE FIG. 21 FIG. 20 PHOTOCONTROL ON/OFF ZONE SINGLE W/ 2P INTERCHANGEABLE FIXTURE LENS MOUNT: VOLTAGE LINE FIG. 19 2-POLE INTERCHANGEABLE FIXTURE LENS MOUNT: VOLTAGE LINE LINE VOLTAGE INTERCHANGEABLE FIXTURE LENS MOUNT VOLTAGE LINE FIG. 18 INTERCHANGEABLE LENS OCCUPANCY SENSORS OCCUPANCY LENS INTERCHANGEABLE DAYLIGHT CONTROL OCCUPANCY SENSORS

FIG. 22 LOW VOLTAGE ON/OFF PHOTOCONTROLS

BLK - 120 V PP20 ORN - 277 V DAYLIGHT HARVESTING CONTROL HARVESTING DAYLIGHT

CAP OFF

FIG. 23 LOW VOLTAGE ON/OFF PHOTOCONTROL W/ LOW VOLTAGE OCCUPANCY SENSORS

BLK - 120 V PP20 ORN - 277 V WIRING DIAGRAMS

CAP OFF

FIG. 24 LINE VOLTAGE AUTO DIMMING PHOTOCONTROLS

0-10 VDC BALLAST

FIG. 25 LINE VOLTAGE ON/OFF PHOTOCONTROLS

88 / www.acuitycontrols.com DAYLIGHT HARVESTING CONTROL WIRING DIAGRAMS www.acuitycontrols.com / 89 www.acuitycontrols.com BLK - 120 V - 120 BLK V ORN - 277 BALLAST 0-10 VDC CAP OFF CAP BLK - 120 V - 120 BLK V ORN - 277 BALLAST 0-10 VDC BLK - 120 V - 120 BLK V ORN - 277 BALLAST 0-10 VDC & wire BLU to an Additional PP20 to an BLU & wire

*Wire VIO to additional 0-10 VDC Ballast VIO to additional 0-10 *Wire PP20 *Wire to an additional 0-10 VDC Ballast to an additional 0-10 *Wire PP20 PP20 - DUAL ZONE OPTION* ZONE - DUAL DZ - DUAL ZONE OPTION* ZONE - DUAL DZ CAP OFF CAP LOW VOLTAGE ON/OFF & AUTOMATIC DIMMING PHOTOCONTROL W/ LOW VOLTAGE OCCUPANCY SENSORS VOLTAGE LOW W/ PHOTOCONTROL DIMMING & AUTOMATIC ON/OFF VOLTAGE LOW FIG. 28 LOW VOLTAGE ON/OFF & AUTOMATIC DIMMING PHOTOCONTROLS DIMMING & AUTOMATIC ON/OFF VOLTAGE LOW FIG. 27 FIG. 26 PHOTOCONTROLS DIMMING AUTOMATIC VOLTAGE LOW POWER PACKS & SECONDARY PACKS

FIG. 29 MULTIPLE SENSORS CONTROLLING ONE CIRCUIT BLK - 120 V PP20 ORN - 277 V POWER PACKS & SECONDARY PACKS & SECONDARY POWER PACKS

FIG. 30 ONE SENSOR CONTROLLING TWO CIRCUITS BLK - 120 V PP20 2P ORN - 277 V WIRING DIAGRAMS

FIG. 31 WIRING MULTIPLE POWER PACKS BLK - 120 V TOGETHER PP20 ORN - 277 V

BLK - 120 V PP20 ORN - 277 V

BLK - 120 V SP20 ORN - 277 V

90 / www.acuitycontrols.com SPECIALTY POWER PACKS WIRING DIAGRAMS www.acuitycontrols.com / 91 www.acuitycontrols.com Multi - Circuit Latching Contractor Local Momentary Local Switches BLK - 120 V - 120 BLK V ORN - 277 BLK - 120 V - 120 BLK V ORN - 277 or 277 VAC ] VAC or 277 [ Typ. 24, 120, 24, Typ. [ Control Voltage Control PP20 BLK - 120 V - 120 BLK V ORN - 277 PP 2PAR PP20 2PM SENSORS TO REMOTE TO SENSORS TO REMOTE TO

FIG. 34 ALTERNATING OFF RELAY 2PAR) (PP PACK POWER MOMENTARY PACK POWER (PP 2PM) FIG. 33 SPECIALTY POWER PACKS POWER SPECIALTY FIG. 32 ONE SENSOR CONTROLLING ONE CIRCUIT WALLPODS

FIG. 35 BI-LEVEL (AUTO-ON / MANUAL ON) SOLUTION W/ OCCUPANCY SENSOR: SINGLE GANG WALLPODS

Class 1 Connections

PP20 SP20

AUTO MANUAL ON ON LOAD LOAD

If No Sensor is Used, Tie the sPODM White Wire to Red Wire

FIG. 36 Class 1 MANUAL Connections ON/DIMMING W/

WIRING DIAGRAMS OCCUPANCY SENSOR PP20

0 - 10 VDC BALLAST

If Sensor Also Has Dimming Output, Connect Sensor VIO Wire to SPODM and Ballast VIO Wire If No Sensor is Used, Tie the sPODM White Wire to Red Wire

FIG. 37 3-WAY MANUAL Class 1 Connections ON SOLUTION W/ OCCUPANCY SENSOR: PP20 SINGLE GANG

CAP OFF

If No Sensor is Used, Tie the sPODM White Wire to Red Wire

92 / www.acuitycontrols.com EMBEDDED OCCUPANCY SENSORS WIRING DIAGRAMS 120 OR 277 VAC www.acuitycontrols.com / 93 www.acuitycontrols.com Class 1 Connections Class ON ON LOAD AUTO LOAD MANUAL LED BALLASTS DRIVERS / If No Sensor is Used, Tie the sPODM White Wire to Red Wire to Red Wire White the sPODM Tie If No Sensor is Used, SP20 PP20 120 OR 277 VAC FIG. 40 OPERATION HIGH/LOW SNAP-FIT SENSORS VOLTAGE LOW FIG. 42 2-POLELINE EMBEDDED VOLTAGE SMALL SENSORS BOX ) 0 - 10 VDC 0 - 10 LED DRIVER / BALLAST DC Power (12-24V DC Power

LOW VOLTAGE HIGH/LOW HIGH/LOW VOLTAGE LOW OPERATION EMBEDDED SENSORS FIG. 41 LINE VOLTAGE SNAP FIT SENSORS FIT SNAP VOLTAGE LINE FIG. 39 EMBEDDED OCCUPANCY SENSORS OCCUPANCY EMBEDDED FIG. 38 BI-LEVEL (AUTO-ON ON) / MANUAL SOLUTION W/ SENSOR: OCCUPANCY TWO-GANG

/ PRODUCT INDEX

B 44 CMRB PDT 9 R 69 SBR PDT 10 44 CMRB PDT 9 2P 69 SBR PDT 9 2P 79 BD1 40 RM 9 44 CMRB PDT 10 69 SBR PDT 10 2P 40 RM 10 44 CMRB PDT 10 2P 65 SFD 7 42 RM ADC 65 SFD 30 C 42 RM PC 68 SFD ADC WH 32 CM WR 42 RM PC ADC 66 SFOD 7 ODP 34 CM 6 H 40 RM PDT 9 56 HW13 66 SFOD 30 ODP 34 CM 9 40 RM PDT 10 44 HMB 10 64 SFR 7 34 CM 10 40 RMR 9 44 HMRB 10 64 SFR 30 34 CM 11 40 RMR 9 2P 44 HMRB 10 208 60 SP20 38 CM ADC 40 RMR 10 44 HMRB 10 480 30 SPODM 38 CM PC 40 RMR 10 2P 44 HMRB 10 2P 33 SPODMR WR 38 CM PC ADC 42 RMR ADC 56 HWR13 26 SSD 34 CM PDT 9 42 RMR PC 34 CM PDT 10 42 RMR PC ADC 34 CM PDT 11 40 RMR PDT 9 44 CMB 6 L 40 RMR PDT 9 2P W 76 LQDM 6 KIT 78 WG1 44 CMB 9 40 RMR PDT 10 50 LSXR 78 WG2 44 CMB 10 40 RMR PDT 10 2P 28 LWS 78 WG3 44 CMB 50 28 LWS PDT 78 WG4 48 CMB ADC 28 LWSH 24 WSD 48 CMB PC S 28 LWSH PDT 24 WSD 2P 48 CMB PC ADC 69 SB 6 27 WSD LV 44 CMB PDT 9 69 SB 9 24 WSD PDT 44 CMB PDT 10 69 SB 10 24 WSD PDT 2P 34 CMR 6 M 69 SB 50 60 MP20 27 WSD PDT LV 34 CMR 9 69 SB PDT 9 60 MP5 480 22 WSX 34 CMR 9 2P 69 SB PDT 10 62 MSD 7 22 WSX 2P 34 CMR 10 72 SBG 6 63 MSOD 7 ODP 22 WSX 2P NL 34 CMR 10 2P 71 SBGR 6 60 MSP20 22 WSX NL 38 CMR ADC 71 SBGR 6 2P 22 WSX PDT 38 CMR PC 73 SBGR 6 ODP 22 WSX PDT 2P 38 CMR PC ADC 71 SBGR 9 22 WSX PDT 2P NL 34 CMR PDT 9 P 71 SBGR 9 2P 60 PP 2PAR 22 WSX PDT NL 34 CMR PDT 9 2P 72 SBG 10 60 PP20 56 WV 16 34 CMR PDT 10 71 SBGR 10 60 PP20 2P 57 WV BR 34 CMR PDT 10 2P 71 SBGR 10 2P 60 PP 2PM 56 WV PDT 16 44 CMRB 6 73 SBGR 10 ODP 60 PP20 SH 56 WVR 16 44 CMRB 6 208 70 SBGR PC 31 PTS 60 56 WVR PDT 16 44 CMRB 6 480 71 SBGR PDT 9 31 PTS 720 44 CMRB 6 2P 71 SBGR PDT 10 44 CMRB 9 58 SBO 44 CMRB 9 2P 58 SBOR 44 CMRB 10 69 SBR 6 44 CMRB 10 2P 69 SBR 6 2P 44 CMRB 50 69 SBR 9 44 CMRB 50 208 69 SBR 9 2P 44 CMRB 50 480 69 SBR 10 44 CMRB 50 2P 69 SBR 10 2P 48 CMRB ADC 69 SBR 50 48 CMRB PC 69 SBR 50 2P 48 CMRB PC ADC 69 SBR PDT 9 Acuity Brands, Inc. One Lithonia Way, Conyers, GA 30012 800-535-2465 www.acuitycontrols.com © Acuity Brands Lighting, Inc. All Rights Reserved. 07/15 Form 1412.001