Contact Protection Reed Switch Contacts, Although Rugged, Can Require Protection from Certain Loads

Total Page:16

File Type:pdf, Size:1020Kb

Contact Protection Reed Switch Contacts, Although Rugged, Can Require Protection from Certain Loads Contact Protection Reed Switch contacts, although rugged, can require protection from certain loads Contact Protection Reedswitches can exhibit a high degree of reliability. Their contacts are sealed in an ultra clean environment at a predetermined pressure or vacuum, specifically chosen for their intended areas of application. The contact material, the size of the switch and the mechanical form may also be developed with some particular application in mind. Reed switches can be used at low level in circuits passing pico and micro amps, with associated switch insulation resistance in the order of 1014 if required, through to high voltage versions capable of switching 15kV or power versions that can handle several amps. Careful attention should be paid to the manufacturers’ published technical literature, to ensure the correct switch type and sensitivity range within that switch type is selected. It is assumed, in this application note, that the most suitable switch has been selected for the intended application and that the remaining problems are associated with the external factors that influence switch life, particularly external load applications. Capacitive loads: Long wires Capacitance across a reed switch can dramatically reduce life and even cause early contact sticking. This can occur even with low values of capacitance associated with circuit wiring. Damaging current surges occur at make or closure, in capacitive circuits, that will exceed the rating of the contact. Measures should be taken to reduce the inrush current to a minimum. The most common solution is to fit a resistor in series with the switch. Cable R1 RS V C Load R2 Lamp Loads It is important to note, with lamp loads, that cold filaments have a resistance approximately 10 times smaller than already glowing filaments. This means that, when turned on, the lamp filament draws a current 10 times greater than when hot. This high inrush current can be reduced to an acceptable level, through the use of a current limiting resistor in series with the switch. RS RS R1 R2 V Lamp V Lamp Lamp load with parallel or current limiting resistor across the switch Inductive Loads: Relays, Solenoids and Motors Many applications involve interfacing the main load through a relay system, in order to handle larger values of voltage or current. Coil operated relays or solenoid control valves possess considerable inductive values. The significant factor to guard against is the release of energy, temporarily stored in the coil, at the time the reed switch opens. The collapsing magnetic field, when an inductive circuit is broken, causes a voltage transient or back EMF. This will eventually lead to complete welding of the switch. There is a choice of devices that can be used for contact suppression that includes diodes, RC snubber circuit, metal oxide varistors or transient voltage suppression diode. The two most common methods of suppression are diode and RC (resistor capacitor) suppression. Diode suppression (DC circuits only) The diode is excellent for removing the inductive voltage spike, as the back EMF is directed through the diode. Contact erosion is reduced to a minimum but, when placed across a relay coil, release time of the relay contacts will be increased by several milliseconds while the stored energy is being dissipated. The diode chosen must have a forward current rating equal to, or greater than, the steady state current of the circuit and the diode must be connected cathode to positive. RC suppression RC suppression can be used of AC or DC circuits. The associated release time of the RC suppressed relay contacts is faster, although not so efficient in removing the inductive transient. The calculated value of R must be checked, to ensure that the capacitive surge is reduced to a safe value for the type of switch in question. A resistor and capacitor, connected in parallel with the switch, as shown below, is recommended. Transient voltage suppressors or varistors may also be used to dissipate the transient and protect the contacts. Motors The circuit can appear as a high inductance and low resistance, at the moment of switch closure. Surge current during starting could be some 5 to 15 times the steady value and, depending on the type of motor and starting characteristics, could last for several seconds in the worst case. The nomagraph below can be used to calculate the RC values required to achieve the necessary contact protection. The upper nomograph can be used for determining contact arc suppression for R inductive loads. 10000 I 10 Example 1: I = 0,1 A 8000 V = 230 V C = 0,001 microfarads 6000 8 R = 340 ohms 4000 6 Example 2: If the current inrush is critical use the lower nomograph to determine the A Ω 4 minimum resistance. in 2000 C I = 0,5 A 1 Rmin = 400 ohms 0,8 nce in a t urrent 0,6 s i 1000 C 0,4 2 s 800 R e 0,2 600 F µ 400 in r 0,1 1 o t 0,08 ci 0,06 0,8 a p 0,04 5 200 a 0,6 6 L oad voltage in V C 8 0,02 10 0,4 20 100 0,01 30 50 80 0,008 60 0,006 0,004 0,2 40 0,002 20 A 300 V 20 0,001 200 V 0,1 10 A e g h a 100 V 0,08 t l 5 A o 50 V 10 v 0,06 inrus 8 d 25 V a o 6 2 A L 10 V 0,04 current current 4 1 A x. x. a m 0,5 A 0,02 R S 2 I L oad 1 V 0,01 R C .
Recommended publications
  • GE Kv Vector Electricity Meter
    GEH-5081B GE kV™ Vector Electricity Meter Product Description Option Board Installation Procedures, Operating Instructions, Maintenance Instructions and Site Analysis Guides Price: $ 30.00 Notice The information contained in this document is subject to change without notice. GE makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. GE shall not be liable for errors contained herein or incidental consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied or otherwise reproduced without consent of GE. Copyright (c) 1997 by GE Published in a limited copyright sense, and all rights, including trade secrets, are reserved. Document Edition - First 4/96 - Version A 5/97 - Version B 11/97 kV™, Lexan™, MeterMate™, OPTOCOM™, Power Guard™, Site Genie™, Fitzall, and SMARTCOUPLER™ are trademarks of GE. FCC COMPLIANCE STATEMENT This product generates and uses radio frequency energy. It has been tested and verified that it complies with the limits for the Code of Federal Regualtions (CFR) 47, Part 15 Radio Frequency Devices, Subparts A General and B Unintentional Radiators issued by the Federal Communications Commission for Class “B” digital devices. If, however, the product causes radio or television interference, notify: Manager - Technology General
    [Show full text]
  • Moeller Wiring Manual 02/05 Specifications, Formulae, Tables
    Moeller Wiring Manual 02/05 Specifications, Formulae, Tables Page Marking of electrical equipment 9-2 Circuit symbols, European – North America 9-14 Circuit diagram example to North American specifications 9-27 Approval authorities worldwide 9-28 Test authorities and approval stamps 9-32 Protective measures 9-34 Overcurrent protection of cables and conductors 9-43 Electrical equipment of machines 9-51 Measures for risk reduction 9-56 Measures for risk avoidance 9-57 Degrees of protection for electrical equipment 9-58 North American classifications for control switches 9-68 9 Utilisation categories for contactors 9-70 Utilisation categories for switch-disconnectors 9-74 Rated motor currents 9-77 Conductors 9-81 Formulae 9-90 International unit system 9-94 For Immediate Delivery call KMParts.com at (866) 595-96169-1 Moeller Wiring Manual 02/05 Specifications, Formulae, Tables Marking of electrical equipment General Extracts from the DIN Standards with VDE The marking appears in a suitable position as Classification are quoted with the permission of close as possible to the circuit symbol. The the DIN (Deutsches Institut für Normung e.V.) and marking forms the link between the equipment in the VDE (Verband der Elektrotechnik Elektronik the installations and the various circuit documents Informationstechnik e.V.) It is imperative for the (wiring diagrams, parts lists, circuit diagrams, use of the standards that the issue with the latest instructions). For simpler maintenance, the date is used. These are available from complete marking or part of it, can be affixed on VDE-VERLAG GMBH, Bismarckstr. 33, 10625 or near to the equipment.
    [Show full text]
  • Nortec RS Steam Humidifier Operation Manual
    2582418-A EN | 06 AUG 2015 EN | 06 2582418-A OPERATION MANUAL Steam humidifier Nortec RS Humidification and Evaporative Cooling Thank you for choosing Nortec Installation date (MM/DD/YYYY): Commissioning date (MM/DD/YYYY): Site: Model: Serial number: Manufacturer Nortec Humidity Ltd. 2740 Fenton Road, Ottawa, Ontario K1T3T7 TEL: 1.866.NORTEC1, FAX: 613.822.7964 EMAIL: [email protected], WEBSITE: www.humidity.com Proprietary Notice This document and the information disclosed herein are proprietary data of Nortec Humidity Ltd. Neither this do- cument, nor the information contained herein shall be reproduced, used, or disclosed to others without the written authorization of Nortec Humidity Ltd., except to the extent required for installation or maintenance of recipient's equipment. Liability Notice Nortec Humidity Ltd. does not accept any liability due to incorrect installation or operation of the equipment or due to the use of parts/components/equipment that are not authorized by Nortec Humidity Ltd. Copyright Notice Copyright 2015, Nortec Humidity Ltd. All rights reserved. Technical modifications reserved Contents 1 Introduction 5 1.1 Before You Begin 5 1.2 Notes on the Operation Manual 5 2 For Your Safety 7 3 Product Overview 9 3.1 Construction Nortec RS steam humidifier 9 3.2 Functional Description 10 3.3 System Overview Nortec RS 11 3.4 System Overview Nortec RS for Direct Room Humidification 12 4 Operation 13 4.1 First-time Commissioning 13 4.2 Display and Operating Elements 13 4.3 Commissioning After an Interruption of Operation
    [Show full text]
  • Automotive Relay Users Guide
    Automotive Relay Users Guide ASCTB237E 2021.04 industrial.panasonic.com/ac/e/ Automotive Relay Users Guide Please use the check sheet. Category Section Contents 1. Confirmation 1) Confirmation under The rated switching power and life mentioned in the specification and catalog are given only as guides. A relay under the the actual use may encounter a variety of ambient conditions during actual use resulting in unexpected failure. Therefore, it is actual use necessary for proper use of the relay to test and review with actual load and actual application under actual condition operating conditions. 2. Safety 1) Specification range Use that exceeds the specification ranges such as the coil rating, contact rating and expected life should be precautions absolutely avoided. Doing so may lead to abnormal heating, smoke, and fire. 2) Installation, Never touch energized parts when power is applied to the relay. Doing so may cause electrical shock. When maintenance installing, maintaining, or troubleshooting a relay (including connecting parts such as terminals and sockets), be sure that the power is turned off. 3) Connection When connecting terminals, please follow the internal connection diagrams in the catalog to ensure that connections are done correctly. Be warned that an incorrect connection may lead to unexpected operation error, abnormal heating, and fire. 4) Fail-safe If there is a possibility that adhesion, contact failure, or breaking of wire could endanger assets or human life, please make sure that a fail-safe system is equipped in the vehicle. 3. Selection of 1) Selection In order to use the relays properly, the characteristics of the selected relay should be well known, and the relay type conditions of use of the relay should be investigated to determine whether they are matched to the environmental conditions, and at the same time, the coil specification, contact specification, and the ambient conditions for the relay that is actually used must be fully understood in advance.
    [Show full text]
  • RELAY and CONTROL REQUIREMENTS for PARALLEL OPERATION of DISTRIBUTED GENERATION (12Kv and Below)
    EU00536095 RELAY AND CONTROL REQUIREMENTS FOR Revision:0 PARALLEL OPERATION OF GENERATION Effective Date: 12/11/2017 Page 1 of 67 PPL ELECTRIC UTILITIES CORPORATION RELAY AND CONTROL REQUIREMENTS FOR PARALLEL OPERATION OF DISTRIBUTED GENERATION (12kV and below) REV. 0, 12/11/2017 By: Deepak Sharma Reviewer: signed Thien Hoang – Supervising Engineer Distribution Design and Standards Approver: signed Michael J. Wolf – Supervising Engineer Distribution Substation Design SHEET 1 of 67 EU00536095 RELAY AND CONTROL REQUIREMENTS FOR Revision:0 PARALLEL OPERATION OF GENERATION Effective Date: 12/11/2017 Page 2 of 67 TABLE OF CONTENTS TABLE OF CONTENTS ........................................................................................................................... 2 1 FOREWORD ........................................................................................................................................ 5 2 SCOPE ................................................................................................................................................... 6 3 OVERVIEW .......................................................................................................................................... 7 3.1 INITIATING A REQUEST TO INSTALL OR CHANGE OPERATION OF GENERATION EQUIPMENT ............................................................................................................................................................. 8 3.2 POINT OF CONTACT (POC) and INTERTIE PROTECTIVE RELAYING (IPR) ...................................
    [Show full text]
  • Panasonic Switches
    GENERAL CATALOG SWITCHES Panasonic Switches Development cycles in modern industry are becoming ever shorter and more complex, and they require a high degree of engineering. Components integrated into machines must therefore not only meet the current qualitative and technical standards but must also fulfill functional and application demands. Individual products can often only be integrated after they have been customized. Panasonic Electric Works has always stood for product innovation – also when it comes to mechanical switches. Our immense portfolio includes switches in all common sizes and with various IP degrees of protection, and are guaranteed to cover all standard requirements. Our switches are characterized by a large switching capacity range, long lifetime and exceptional reliability. A wide selection of supplemental actuators coupled with various terminal styles, e.g. solder, quick connect, PC board terminal and cable connections, maximize flexibility and ease application design. In addition, we concentrate on the development and implementation of customer-specific solutions: Does the cable have to be a little bit longer? Or is a pluggable solution necessary? With the engineering know-how at our European manufacturing sites, we guarantee flexible, on-time delivery and provide immediate, on-site technical support. Product lineup 36 3 1 8 ASQ ABJ ABS ABV 8 2 27. 8 AV4 AH1 AEQ AV3/AVM3/AVT3/AVL3 AV6 AM5 AM1 AV1 AGX AJ7/8 T Series Tailoring equipment 2 Contents Selector Chart........................................................... 4 AM5 (QV) switches (contact gap more than 1mm).. 80 Micro switches IP67.................................................... 4 AEQ (EQ) switches.................................................. 81 Micro switches IP40.................................................... 6 AV (FS•FS-T) switches............................................ 86 Basic switches......................................................
    [Show full text]
  • Technical Information ■ Relay Classification
    Introduction Introduction Technical Information ■ Relay Classification Model Mounting Enclosure Ratings Features G4W Discrete Unsealed Designed for manual soldering. G2R Flux protection Designed inhibits flux intrusion into the casing from the ter- minals during soldering. G6A Sealed Sealed resin casings and covers, limiting damage from cor- rosive atmospheres. G6S Surface mounting Surface mounting relays permit automatic reflow soldering. ■ Construction Sealing Sealed Relays Unsealed Relays Fully sealing prevents not only flux, but also cleaning solvent from Relays of this type are intended for manual soldering. No mea- penetrating into the relay housing. Therefore, this type of relay sures are taken against penetration of flux and cleaning solvent can be immersion-cleaned. Relays are each tested before being into the relay. This type of relay cannot be immersion-cleaned. shipped. The relay is immersed in fluorocarbon solution for 1 +5°C Flux-protection Relays minute, at a temperature of 70°C /−0°C, to see if gases escape from the relay. The following figure illustrates the test conditions. Special design construction prevents flux from penetrating into the relay housing, for example, due to capillary action up the ter- minals when the relay is soldered onto a PCB. This type of relay also cannot be immersion-cleaned. 50 mm Ex.) 70 °C Relay Fluorocarbon solution Classification Unsealed Flux protection Construction Contacts located at Press-fit terminals Inserted terminals upper part of relay case Terminals separated from PCB Terminals Resin seal separated Terminals from PCB separated 0.3 mm from PCB min. base thickness Features Terminals are separated Contacts are positioned Terminals are pressed Terminals are inserted from PCB surface when away from base.
    [Show full text]
  • 2003 Cat.Pdf
    What’s New - New Products - What’s New High Voltage Reed Switches Tilt Switch See page 37 This series of switches is designed for Non-Mercury relays which are used in high reliability areas of the elec- trotechnical and electronic industry including electronic medical equip- Changeover ment; cable tester arrays and cable test equipment; copy machines; laser optical systems and infrared equipment; test equipment S1234 They provide high voltage stand-off and switching capability. The tung- See page 78 sten plated contacts give both a low stable CR and a long and reliable life. Surface Mount Mercury free changeover tilt switch with hermetically sealed gold contacts, Switch and and a case size of just 7.6mm. It’s rugged construction makes this Sensors switch suitable for many uses in secu- The Comus Group can now supply rity products, alarm and general move- surface mount termination for a wide ment sensing. rated at 60V, 0.2A and range of products. The gold plated clips See page 70 3VA Max. give good solderability and are designed to provide stability during assembly. Magtrix Connectors are versatile miniature Magtrix Neodymium-iron-boron nickel plated 6.0 Dia x Connector 5mm long magnets connected to a 40 x 0.65mm Dia. copper-tin plated flexible lead, with an operating MC/53GNS temperature of 120°C and a maximum power rating See page of 8 Amps. Primarily designed for use as battery connectors, 68 they are also ideal for proximity sensor and reed switch triggering, connecting PCBs, test equipment connections and prototypes where connections need to be made quickly.
    [Show full text]
  • • Relay Contact Protection • Noise Reduction on Controllers/Drivers • Dv
    Type Q/QRL Quencharc®Capacitor RC Snubber Network Arc Suppressor • Relay contact protection • Noise reduction on controllers/drivers Snubber Network • dv/dt suppression on thyristor and triacs • EMI/RFI reduction • No lag time in suppression • Available voltages: 125 VAC - 660 VAC • Type QRL – UL/CSA version L Max. TMax. ® Quencharc¤ ITW PAKTRON QUENCHARC¤ Arc Suppressor Snubber Network ITW PAKTRON H Max. Q/QRL QUENCHARC¤ UL/CSA version .25" Max. .850" Min. ARCING, SPARKING, and TRANSIENTS often cause premature failures in relays, switches, thyristors, triacs, contactors, and related products. Paktron QUENCHARCS¤ extend operating life when properly selected and applied. D Typ. VoltagE WavefoRM CURRENT WavefoRM Electrical Schematic Non-polarized UNSUPPRESSED SUPPRESSED UNSUPPRESSED SUPPRESSED 100V/div .1ms/div 100V/div .5ms/div 100V/div .1ms/div 100V/div .1ms/div PF Value Voltage Type Ohms Watt L T H D Part Code µF VDC/VAC ±10% MAX MAX MAX Typical Number 104 .1 600 / 250 QC 22 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC22 104 .1 600 / 250 QC 47 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC47 104 .1 600 / 250 QC 100 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC100 104 .1 600 / 250 QC 150 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC150 104 .1 600 / 250 QC 220 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC220 104 .1 600 / 250 QC 330 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC330 104 .1 1200/480 QH 39 2.0 1.60(40.6) .64(16.3) 1.04(26.4) 1.29(32.7) 104M48QH39 104 .1 1600/660 QV 39 2.0
    [Show full text]
  • Operation Manual
    NORTEC 1905 EN D 2582418- OPERATION MANUAL Steam humidifier Nortec RS series Humidification and Evaporative Cooling Thank you for choosing Condair Installation date (MM/DD/YYYY): Commissioning date (MM/DD/YYYY): Site: Model: Serial number: Contact Condair Ltd. 2740 Fenton Road, Ottawa, Ontario K1T3T7 TEL: 1.866.667.8321, FAX: 613.822.7964 EMAIL: [email protected], WEBSITE: www.condair.com Proprietary Notice This document and the information disclosed herein are proprietary data of Condair Ltd. Neither this document, nor the information contained herein shall be reproduced, used, or disclosed to others without the written authorization of Condair Ltd., except to the extent required for installation or maintenance of recipient's equipment. Liability Notice Condair Ltd. does not accept any liability due to incorrect installation or operation of the equipment or due to the use of parts/components/equipment that are not authorized by Condair Ltd. Copyright Notice © Condair Ltd. All rights reserved. Technical modifications reserved Contents 1 Introduction 5 1.1 To the very beginning 5 1.2 Notes on the operation manual 5 2 For your safety 7 3 Product Overview 9 3.1 Construction Nortec RS steam humidifier 9 3.2 Functional description 10 3.3 System overview Nortec RS 11 3.4 System overview Nortec RS for direct room humidification 12 4 Operation 13 4.1 First-time commissioning 13 4.2 Display and operating elements 13 4.3 Commissioning after an interruption of operation 14 4.4 Notes on operation 15 4.4.1 Inspections during operation 15 4.4.2 Remote
    [Show full text]
  • No-Arc Relay Operation Products Affected: E-SAFE II, EHG II, EZ-ZONE PM
    No-arc Relay Operation Products Affected: E-SAFE II, EHG II, EZ-ZONE PM Background Shortened mechanical relay life occurs when contacts open while current is flowing through the contacts. This action produces an electrical arc causing metal to transfers from one contact to the other contact. As the metal transfers on each contact opening, the resistance through the contacts increases causing the contacts to increase in temperature. In time, the contacts weld together and the relay remains in the ‘ON’ state. Theory of Operation The Watlow E-SAFE® II, EHG™ II and EZ-ZONE™ PM (Option PM6xxxH-xxxxxxx) are hybrid relays, which means these use a mechanical relay for current load and a triac (solid state switch) to initially turn on the load current and at the end of the cycle to turn the load current off, which will minimize the electrical arc across the relay. The operation is as follows: Off State – when there is no command signal, both the relay and the triac are off. Watlow Winona LC 11/13/07 1241 Bundy Blvd Winona, MN 55987 Telephone (507) 494-5656 © 2007 Watlow Electric Manufacturing Company No-arc Relay Operation Products Affected: E-SAFE II, EHG II, EZ-ZONE PM Turn On State – when the command signal is applied to turn on the load, the triac carries the load for the first cycle at turn ‘ON’. The triac, being solid state turns on at zero volts in the sine wave, thereby eliminating the arc. Conduction State – at the end of the first cycle, the mechanical relay pulls in to carry the load for the duration of the on signal.
    [Show full text]
  • Inductive Load Arc Suppression Application Note
    Application Note: Inductive Load Arc Suppression Figure 2. Introduction Bidirectional TVS Diode When a reed switch or reed sensor is used to control an Reed Switch/Sensor inductive device (relay coil, solenoid, transformer, small motor, etc.), the energy stored in the inductance in the device Load will subject the switch contacts to a high voltage when the reed switch opens. When the switch contacts open, the contact gap is initially small. Arcing across this contact gap RL can occur immediately after the switch opens. This can TVS Vs happen in resistive as well as inductive loads, but inductive loads generate a higher voltage and this causes increased L arcing. Increased arcing decreases switch life. Direct current (DC) inductive circuits typically use a diode to prevent the high voltage. The diode in the circuit is called a suppression diode, flyback diode, freewheeling diode, or catch diode. However, a diode cannot be used in an alternating current (AC) circuit. AC arc suppression requires the use of a RC suppression has the advantage of limiting the switch metal-oxide varistor (MOV), a bidirectional transient voltage contact voltage at the time of switch opening when the suppressor (TVS) diode, or an RC suppression network. An size of the contact gap is small. RC suppression can also RC suppression network is also called a snubber. The various be used to reduce arcing and improve life in resistive arc suppression methods have various advantages and loads. With RC suppression, a seriesconnected capacitor disadvantages. Using no suppression is also an option if life and resistor network is placed across (in parallel with) the is adequate without it.
    [Show full text]