Electrical and Electronics Engineering List of Courses

Total Page:16

File Type:pdf, Size:1020Kb

Electrical and Electronics Engineering List of Courses ELECTRICAL AND ELECTRONICS ENGINEERING LIST OF COURSES Course S.No Course Name L:T:P Credit Code 1 18EE1001 Basic Electrical Engineering 3:1:0 4 2 18EE1002 Basic Electrical Engineering Laboratory 0:0:2 1 3 18EE1003 Basic Electrical and Electronics Engineering 3:1:0 4 4 18EE1004 Basic Electrical and Electronics Engineering Laboratory 0:0:2 1 5 18EE1005 Electrical Workshop Practices 1:0:4 3 6 18EE2001 Electrical Circuit Analysis 3:1:0 4 7 18EE2002 Network Theory 3:0:0 3 8 18EE2003 Analog Electronic Circuits 3:0:0 3 9 18EE2004 Analog Electronic Circuits Laboratory 0:0:3 1.5 10 18EE2005 Electromagnetic Fields 3:1:0 4 11 18EE2006 Electrical Machines – I 3:0:0 3 12 18EE2007 Electrical Machines - I Laboratory 0:0:2 1 13 18EE2008 Electrical Machines – II 3:0:0 3 14 18EE2009 Electrical Machines – II Laboratory 0:0:2 1 15 18EE2010 Power Electronics 3:0:0 3 16 18EE2011 Power Electronics Laboratory 0:0:2 1 17 18EE2012 Power Systems – I 3:0:0 3 18 18EE2013 Power Systems – I Laboratory 0:0:2 1 19 18EE2014 Power Systems – II 3:0:0 3 20 18EE2015 Power Systems – II Laboratory 0:0:2 1 21 18EE2016 Wind and Solar Energy Systems 3:0:0 3 22 18EE2017 Wind and Solar Energy Laboratory 0:0:2 1 23 18EE2018 Industrial Mechatronics 3:0:0 3 24 18EE2019 Electric Machines and Drives 3:0:0 3 25 18EE2020 Electric Machines and Drives Laboratory 0:0:2 1 26 18EE2021 Electrical Machines and Power Systems 3:0:0 3 27 18EE3001 Energy Engineering 3:0:0 3 28 18EE3002 Photovoltaic Systems 3:0:0 3 29 18EE3003 Energy Management and Audit 3:0:0 3 30 18EE3004 Wind Energy 3:0:0 3 31 18EE3005 Solar Energy Laboratory 0:0:4 2 32 18EE3006 Electric Drives Laboratory for Renewable Energy 0:0:4 2 33 18EE3007 Wind Energy Laboratory 0:0:4 2 34 18EE3008 Power Engineering Simulation Laboratory 0:0:4 2 35 18EE3009 Solar Thermal Energy Conversion 3:0:0 3 36 18EE3010 Materials for Solar Power 3:0:0 3 37 18EE3011 Solar Cell and Module Technology 3:0:0 3 38 18EE3012 Grid Converters for Solar and Wind Power Systems 3:0:0 3 39 18EE3013 Biomass Energy 3:0:0 3 40 18EE3014 Waste to Energy Conversion 3:0:0 3 41 18EE3015 Oceanic Energy 3:0:0 3 42 18EE3016 Data Mining for Renewable Energy Systems 3:0:0 3 43 18EE3017 Power Conversion and Control of Wind Energy Systems 3:0:0 3 44 18EE3018 Power Quality Issues and Mitigation 3:0:0 3 45 18EE3019 Distributed Generation and Micro grid 3:0:0 3 Electrical and Electronics Engineering 46 18EE3020 Cyber Physical Systems Approach To Smart Grid 3:0:0 3 47 18EE3021 Smart Power Grid Renewable Energy Systems 3:0:0 3 48 18EE3022 Electric and Hybrid Vehicles 3:0:0 3 49 18EE3023 Disaster Management 3:0:0 0 L T P C 18EE1001 Basic Electrical Engineering 3 1 0 4 Course Objectives: 1. To impart the basic knowledge about the DC, AC and Magnetic circuits. 2. To comprehend the working of various Electrical Machines. 3. To know about various power converters and electrical installations. Course Outcomes: At the end of this course students will demonstrate the ability to 1. Describe the basic terminologies of DC, AC circuits. 2. Define the basic concepts of Magnetic circuits and transformers. 3. Predict and analyze the behavior of any circuits. 4. Identify the type of electrical machine used for required application. 5. Classify various means of power conversion methodologies. 6. Plan electrical wiring, earthing for house hold and commercial purposes. Module 1: DC Circuits (10 hours) Electrical circuit elements (R, L and C), voltage and current sources, Kirchoff’s laws, analysis of simple circuits with DE excitation. Superposition, Thevenin and Norton Theorems, Time-domain analysis of first- order RL and RC circuits. Module 2: AC Circuits (12 hours) Representation of sinusoidal waveforms, peak and RMS values, phasor representation, real power, reactive power, apparent power, power factor. Analysis of single-phase AC circuits consisting of R, L, C, RL, RC, RLC combinations (series and parallel), resonance. Three phase balanced circuits, voltage and current relations in star and delta connections. Introduction to Three phase system. Module 3: Magnetic Circuits & Transformers (8 hours) Magnetic materials, B-H characteristics, Basics of ideal and practical transformer, equivalent circuit, losses in transformers, regulation and efficiency. Auto-transformer and three-phase transformer connections. Module 4: Electrical Machines (10 hours) Construction, working principle, types and applications of DC Generator, DC Motor, Three phase & Single- Phase Induction Motor, Synchronous Generator, Stepper Motor and Servo Motor. Module 5: Introduction to Android Platform (11 hours) Introduction to Android platform – UI widgets – UI managers – different devices &drawables – Intents & fragments – styles and themes – data storages – Asynctask – Broadcast receiver notification and GCM – applications Module 6: Electrical Installations (9 hours) Components of LT Switchgear: Switch Fuse Unit (SFU), MCB, ELCB, MCCB, Types of Wires and Cables, Earthing. Types of Batteries, Important Characteristics for Batteries. Elementary calculations for energy consumption, power factor improvement and battery backup Text Books: 1. Kothari D. P, NagrathI. J., “Basic Electrical Engineering”, Tata McGraw Hill, 2010. 2. Kulshreshtha D. C., “Basic Electrical Engineering”, McGraw Hill, 2011 Reference Books 1. L. S. Bobrow, “Fundamentals of Electrical Engineering”, Oxford University Press, 2011. 2. E. Hughes, “Electrical and Electronics Technology”, Pearson, 2010. 3. Vincent Del Toro, “Electrical Engineering Fundamentals”, Prentice Hall India, 2nd Edition, 2013. Electrical and Electronics Engineering 4. Bhattacharya. S. K, “Basic Electrical and Electronics Engineering”, Pearson Education, New Delhi, 2011. 5. https://www.unanth.com/online-course/learn-to-develop-an-android-app-in-10-hours L T P C 18EE1002 Basic Electrical Engineering Laboratory 0 0 2 1 Co-requisite: 18EE1001 Basic Electrical Engineering Course Objectives: 1. To learn the basic safety of electrical engineering and measuring instruments. 2. To know the working of various AC, DC Circuits and Electrical Machines. 3. To be familiar with various power converters and electrical installations. Course Outcomes At the end of this course students will demonstrate the ability to 1. Get an exposure to common electrical components and their ratings. 2. Make electrical connections by wires of appropriate ratings. 3. Understand the usage of common electrical measuring instruments. 4. Understand the basic characteristics of transformers and electrical machines. 5. Get an exposure to the working of Switchgears. 6. Get an exposure to use of Android and projects with android. Description: The laboratory will demonstrate the student about the certain basic concepts in electrical engineering. List of experiments: 1. Study of basic safety precautions; Introduction and use of measuring instruments – voltmeter, ammeter, multi-meter, oscilloscope. Real-life resistors, capacitors and inductors. 2. Measuring the steady-state and transient time-response of R-L, R-C, and R-L-C circuits to a step change in voltage (transient may be observed on a storage oscilloscope). 3. Sinusoidal steady state response of R-L, and R-C circuits – impedance calculation and verification. 4. Stair case wiring, Fluorescent tube light wiring, Comparison of LED and CFL wiring. 5. Observation of phase differences between current and voltage, Resonance in R-L-C circuits. 6. Demonstration of cut-out sections of machines: DC machine, Induction machine, Synchronous machine and single-phase induction machine. 7. Android / Arduino based Projects. 8. Torque Speed Characteristic of separately excited DC motor. 9. Torque-Slip Characteristic of an Induction motor. 10. Study of Components of LT switchgear. L T P C 18EE1003 Basic Electrical and Electronics Engineering 3 1 0 4 Course Objective 1. To impart knowledge on the fundamental laws of electrical circuits and the different components and functions of electrical machines. 2. To impart knowledge on electrical measurements and wiring. 3. To impart knowledge on the principles of digital electronics and fundamentals of electron devices. Course Outcome At the end of the course, the student will be able to 1. Define the parameters, illustrate the behavior and solve a given electric circuits. 2. Name the parts, explain the operation and select a suitable electrical machine for an application. Electrical and Electronics Engineering 3. Explain the measurement of both electrical and non-electrical parameters with modern sensors and select a suitable sensor for an application. 4. Plan electrical wiring, earthing for house hold and commercial purposes. 5. Explain the characteristics of electron devices. 6. Explain the operation of a digital circuit. Module 1: Basic Circuits (10 hours) Fundamental laws of electric circuits - Current and Voltage sources - Source Transformation - Resistive Circuits: Series and Parallel, Voltage and Current Division – Kirchoff’s Voltage and Current law – Star – Delta transformation – Capacitance – Inductance – Power and Power factor - Single Phase and Three Phase Balanced circuits. Module 2: Electrical Machines (10 hours) Construction - Principle of operation - Characteristics - Applications of DC Generators, DC Motors, Single Phase and Three Phase Induction Motor, Synchronous Generator and Motor, Stepper Motor, Servomotor Module 3: Electrical Measurements (10 hours) Measurement of Voltage – Current – Power – Energy – Power factor - Temperature Sensor – Pressure Sensor – Force Sensor – Load cell - Anemometer – Fire Sensor – Smoke Detector –
Recommended publications
  • Automotive Relay Users Guide
    Automotive Relay Users Guide ASCTB237E 2021.04 industrial.panasonic.com/ac/e/ Automotive Relay Users Guide Please use the check sheet. Category Section Contents 1. Confirmation 1) Confirmation under The rated switching power and life mentioned in the specification and catalog are given only as guides. A relay under the the actual use may encounter a variety of ambient conditions during actual use resulting in unexpected failure. Therefore, it is actual use necessary for proper use of the relay to test and review with actual load and actual application under actual condition operating conditions. 2. Safety 1) Specification range Use that exceeds the specification ranges such as the coil rating, contact rating and expected life should be precautions absolutely avoided. Doing so may lead to abnormal heating, smoke, and fire. 2) Installation, Never touch energized parts when power is applied to the relay. Doing so may cause electrical shock. When maintenance installing, maintaining, or troubleshooting a relay (including connecting parts such as terminals and sockets), be sure that the power is turned off. 3) Connection When connecting terminals, please follow the internal connection diagrams in the catalog to ensure that connections are done correctly. Be warned that an incorrect connection may lead to unexpected operation error, abnormal heating, and fire. 4) Fail-safe If there is a possibility that adhesion, contact failure, or breaking of wire could endanger assets or human life, please make sure that a fail-safe system is equipped in the vehicle. 3. Selection of 1) Selection In order to use the relays properly, the characteristics of the selected relay should be well known, and the relay type conditions of use of the relay should be investigated to determine whether they are matched to the environmental conditions, and at the same time, the coil specification, contact specification, and the ambient conditions for the relay that is actually used must be fully understood in advance.
    [Show full text]
  • • Relay Contact Protection • Noise Reduction on Controllers/Drivers • Dv
    Type Q/QRL Quencharc®Capacitor RC Snubber Network Arc Suppressor • Relay contact protection • Noise reduction on controllers/drivers Snubber Network • dv/dt suppression on thyristor and triacs • EMI/RFI reduction • No lag time in suppression • Available voltages: 125 VAC - 660 VAC • Type QRL – UL/CSA version L Max. TMax. ® Quencharc¤ ITW PAKTRON QUENCHARC¤ Arc Suppressor Snubber Network ITW PAKTRON H Max. Q/QRL QUENCHARC¤ UL/CSA version .25" Max. .850" Min. ARCING, SPARKING, and TRANSIENTS often cause premature failures in relays, switches, thyristors, triacs, contactors, and related products. Paktron QUENCHARCS¤ extend operating life when properly selected and applied. D Typ. VoltagE WavefoRM CURRENT WavefoRM Electrical Schematic Non-polarized UNSUPPRESSED SUPPRESSED UNSUPPRESSED SUPPRESSED 100V/div .1ms/div 100V/div .5ms/div 100V/div .1ms/div 100V/div .1ms/div PF Value Voltage Type Ohms Watt L T H D Part Code µF VDC/VAC ±10% MAX MAX MAX Typical Number 104 .1 600 / 250 QC 22 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC22 104 .1 600 / 250 QC 47 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC47 104 .1 600 / 250 QC 100 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC100 104 .1 600 / 250 QC 150 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC150 104 .1 600 / 250 QC 220 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC220 104 .1 600 / 250 QC 330 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC330 104 .1 1200/480 QH 39 2.0 1.60(40.6) .64(16.3) 1.04(26.4) 1.29(32.7) 104M48QH39 104 .1 1600/660 QV 39 2.0
    [Show full text]
  • No-Arc Relay Operation Products Affected: E-SAFE II, EHG II, EZ-ZONE PM
    No-arc Relay Operation Products Affected: E-SAFE II, EHG II, EZ-ZONE PM Background Shortened mechanical relay life occurs when contacts open while current is flowing through the contacts. This action produces an electrical arc causing metal to transfers from one contact to the other contact. As the metal transfers on each contact opening, the resistance through the contacts increases causing the contacts to increase in temperature. In time, the contacts weld together and the relay remains in the ‘ON’ state. Theory of Operation The Watlow E-SAFE® II, EHG™ II and EZ-ZONE™ PM (Option PM6xxxH-xxxxxxx) are hybrid relays, which means these use a mechanical relay for current load and a triac (solid state switch) to initially turn on the load current and at the end of the cycle to turn the load current off, which will minimize the electrical arc across the relay. The operation is as follows: Off State – when there is no command signal, both the relay and the triac are off. Watlow Winona LC 11/13/07 1241 Bundy Blvd Winona, MN 55987 Telephone (507) 494-5656 © 2007 Watlow Electric Manufacturing Company No-arc Relay Operation Products Affected: E-SAFE II, EHG II, EZ-ZONE PM Turn On State – when the command signal is applied to turn on the load, the triac carries the load for the first cycle at turn ‘ON’. The triac, being solid state turns on at zero volts in the sine wave, thereby eliminating the arc. Conduction State – at the end of the first cycle, the mechanical relay pulls in to carry the load for the duration of the on signal.
    [Show full text]
  • Inductive Load Arc Suppression Application Note
    Application Note: Inductive Load Arc Suppression Figure 2. Introduction Bidirectional TVS Diode When a reed switch or reed sensor is used to control an Reed Switch/Sensor inductive device (relay coil, solenoid, transformer, small motor, etc.), the energy stored in the inductance in the device Load will subject the switch contacts to a high voltage when the reed switch opens. When the switch contacts open, the contact gap is initially small. Arcing across this contact gap RL can occur immediately after the switch opens. This can TVS Vs happen in resistive as well as inductive loads, but inductive loads generate a higher voltage and this causes increased L arcing. Increased arcing decreases switch life. Direct current (DC) inductive circuits typically use a diode to prevent the high voltage. The diode in the circuit is called a suppression diode, flyback diode, freewheeling diode, or catch diode. However, a diode cannot be used in an alternating current (AC) circuit. AC arc suppression requires the use of a RC suppression has the advantage of limiting the switch metal-oxide varistor (MOV), a bidirectional transient voltage contact voltage at the time of switch opening when the suppressor (TVS) diode, or an RC suppression network. An size of the contact gap is small. RC suppression can also RC suppression network is also called a snubber. The various be used to reduce arcing and improve life in resistive arc suppression methods have various advantages and loads. With RC suppression, a seriesconnected capacitor disadvantages. Using no suppression is also an option if life and resistor network is placed across (in parallel with) the is adequate without it.
    [Show full text]
  • Relay Contact Life
    Application Note Relay Contact Life Relay contacts are available in a variety of metals and alloys, sizes and Because silver and silver alloys sulfidate, contact pressures must be great styles. There is no such thing as a universal contact. The relay user enough to break through this film. (Controlled arcing will also be helpful should select contact materials, ratings, and styles to meet, as precisely in that it burns off the sulfidation, and contact overtravel wipes away the as possible, the requirements of a particular application. Failure to do so residue.) While such pressures have no appreciable effect on silver- can result in contact problems and even early contact failure. cadmium contacts, they do result in increased material wear of fine silver contacts. Also, an interface voltage of several tenths of a volt can result For example, some contact materials require an arc to keep them free of with fine silver contacts because of the sulfide film. This film has been sulfidation, oxidation, and contaminates. Such materials on contacts known to capture and imbed airborne dirt. Breaking through this film used in a dry or low-level circuit can result in the contacts failing electrically generates electrical noise. Because of this, fine silver contacts are not to close the circuit, even though they make physically. The contacts may used for low-level switching, such as audio circuits. Rather, fine silver look clean, but this is deceiving. In reality, there is a very thin film of and silver alloy contacts are for use in circuits of 12 volts, 0.4 ampere, or insulating sulfidation, oxidation or contaminates on the surface of the more.
    [Show full text]
  • Lab Note #107 — Rev A
    7900 INTERNATIONAL DRIVE, SUITE 200, BLOOMINGTON, MN 55425 // 612-928-5546 www.ArcSuppressionTechnologies.com arc suppression! technologies Relay Life ! Unsuppressed vs. Suppressed Arcing ! Lab Note #107 — rev A ABSTRACT Electric current arcing causes significant degradation of the contacts in electromechanical relays and contactors. This contact degradation drastically limits the overall operating life of a relay or contactor to a range of perhaps 100,000 operations … a level representing 1% or less than the mechanical life expectancy of the same device, which can be 10 million, 20 million, or more operations. Arc suppression drastically limits contact destruction caused by electric current arcing. Because the contacts last longer, the operating life of the relay or contactor can be extended much closer to its mechanical life expectancy. PROBLEM Product designers, technicians and engineers are all trained to accept specifications when selecting electromechanical relays and contactors. None of these specifications, however, indicate the very serious impact of electrical contact arcing on relay life expectancy. TESTS Operate a CIT J115F1 “T9A-style” sealed, non-vented relay switching a resistive load at 240Vac, 5kW, 4 second cycle time, 50% duty cycle, under three separate test conditions: I. 100,000 cycles with no suppression element II. 100,000 cycles with a NOsparc arc suppressor* (ASF " 1250**) connected across the relay contacts III. 1 million cycles with a NOsparc arc suppressor* (ASF " 1250**) connected across the relay contacts * A NOsparc MMXac™ **ASF stands for “Arc Suppression Factor.” An ASF = 1 means no effect; an ASF > 1 means reduced arc energy. See Lab Note #103: www.arcsuppressiontechnologies.com/LabNotes.aspx In the first two tests, relays were run at Fig.
    [Show full text]
  • Contact Protection Reed Switch Contacts, Although Rugged, Can Require Protection from Certain Loads
    Contact Protection Reed Switch contacts, although rugged, can require protection from certain loads Contact Protection Reedswitches can exhibit a high degree of reliability. Their contacts are sealed in an ultra clean environment at a predetermined pressure or vacuum, specifically chosen for their intended areas of application. The contact material, the size of the switch and the mechanical form may also be developed with some particular application in mind. Reed switches can be used at low level in circuits passing pico and micro amps, with associated switch insulation resistance in the order of 1014 if required, through to high voltage versions capable of switching 15kV or power versions that can handle several amps. Careful attention should be paid to the manufacturers’ published technical literature, to ensure the correct switch type and sensitivity range within that switch type is selected. It is assumed, in this application note, that the most suitable switch has been selected for the intended application and that the remaining problems are associated with the external factors that influence switch life, particularly external load applications. Capacitive loads: Long wires Capacitance across a reed switch can dramatically reduce life and even cause early contact sticking. This can occur even with low values of capacitance associated with circuit wiring. Damaging current surges occur at make or closure, in capacitive circuits, that will exceed the rating of the contact. Measures should be taken to reduce the inrush current to a minimum. The most common solution is to fit a resistor in series with the switch. Cable R1 RS V C Load R2 Lamp Loads It is important to note, with lamp loads, that cold filaments have a resistance approximately 10 times smaller than already glowing filaments.
    [Show full text]
  • Relay Contact Protection • Noise Reduction on Controllers
    Type Q/QRL Quencharc®Capacitor RC Snubber Network Arc Suppressor • Relay contact protection • Noise reduction on controllers/drivers Snubber Network • dv/dt suppression on thyristor and triacs • EMI/RFI reduction • No lag time in suppression • Available voltages: 125 VAC - 660 VAC • Type QRL – UL/CSA version L Max. TMax. ® Quencharc¤ ITW PAKTRON QUENCHARC¤ Arc Suppressor Snubber Network ITW PAKTRON H Max. Q/QRL QUENCHARC¤ UL/CSA version .25" Max. .850" Min. ARCING, SPARKING, and TRANSIENTS often cause premature failures in relays, switches, thyristors, triacs, contactors, and related products. Paktron QUENCHARCS¤ extend operating life when properly selected and applied. D Typ. VoltagE WavefoRM CURRENT WavefoRM Electrical Schematic Non-polarized UNSUPPRESSED SUPPRESSED UNSUPPRESSED SUPPRESSED 100V/div .1ms/div 100V/div .5ms/div 100V/div .1ms/div 100V/div .1ms/div PF Value Voltage Type Ohms Watt L T H D Part Code µF VDC/VAC ±10% MAX MAX MAX Typical Number 104 .1 600 / 250 QC 22 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC22 104 .1 600 / 250 QC 47 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC47 104 .1 600 / 250 QC 100 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC100 104 .1 600 / 250 QC 150 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC150 104 .1 600 / 250 QC 220 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC220 104 .1 600 / 250 QC 330 .5 1.08 (27.4) .39(9.9) .66 (16.7) .82 (20.8) 104M06QC330 104 .1 1200/480 QH 39 2.0 1.60(40.6) .64(16.3) 1.04(26.4) 1.29(32.7) 104M48QH39 104 .1 1600/660 QV 39 2.0
    [Show full text]
  • Lab Note #103 — Rev C
    7900 INTERNATIONAL DRIVE, SUITE 200, BLOOMINGTON, MN 55425 // 612-928-5546 www.ArcSuppressionTechnologies.com arc suppression! technologies Snubbers ! Are They Arc Suppressors? ! Lab Note #103 — rev C ABSTRACT Electric current arcing causes significant degradation of the contacts in electromechanical relays and contactors. This contact degradation drastically limits the overall life of a relay or contactor to a range of perhaps 10,000 to 100,000 operations … a level far below the mechanical life of the same device, which can be in excess of 20 million operations. Product designers, technicians and engineers are all trained to believe that a snubber connected across the contacts of a relay will reduce or eliminate the arcing. While mostly true for low-power applications, they do not measure up to this claim in high-power applications (2A or more). PROBLEM Product designers, technicians and engineers are all trained to believe that snubbers reduce or eliminate electrical contact arcing in electromechanical relays and contactors in high-power applications (2A or more). TESTS Operate a Tyco T9A open-frame relay switching a Tungsten load at 277Vac, 1.4kW, under three separate test conditions: I. With no suppression element II. With a typical RC Snubber (ITW QuenchArc, 0.1µF+200") connected across the relay contacts III. With a NOsparc MMXac™ arc suppressor connected across the relay contacts NOTE: The QuenchArc was selected as representative of several RC snubbers used in this test, all of which yielded nearly identical results. Snubber ranges: R=15Ω to 470Ω; C=0.01µF to 0.22µF. Data is collected using an oscilloscope connected to a differential voltage probe across the relay contacts and a high speed current probe to measure the current through the contacts during operation under load.
    [Show full text]
  • Reed Switches Contacts Protection
    Reed switches contacts protection Reed switches contacts protection J.Jumeau 20121030 Reed switches contacts protection P 1/1 Description of the different parts The electrical contact system: reed switch or micro-switch. A certain force is required to actuate the electrical contact device. It can range from a few tenths of grams for systems with reed contacts with a power rating of 10 to 20VA (0.5Amp), to 50 grams for snap action micro-switches with a 5Amp 250V rating In general, the force required to operate an electrical contact increases with its electrical rating, and the power available on the detector depends on the paddle, piston or flap characteristics Most flow switches in this catalog use reed switches because they are used for detection level in low voltage and low current electronic circuits. This makes possible to design compact devices. Reed switches Reed switches are small glass bulbs with a flexible reed strip contact with a breaking capacity of 10 to 70VA, which has the particularity to close in the presence of a magnetic field. These glass bulbs are sealed and filled with argon or under vacuum, therefore they are protected from oxidation Reed switch applications in flow switches Suitable Not suitable Computer circuits Small electrical motors , including small DC motors Programmable logic controller (PLC’s) circuits Power contactor coil circuits (Unless protected by an arc suppression circuit) Small relays Solenoid valves (Unless protected by an arc suppression circuit) Solid state relay (SSR) trigger circuits Incandescent lamps Reed switches contact protection Switching no load or loads where the voltage is less than 5 Volts @ 10 mA or less, the contacts undergo little or no wear and life times in excess of billions of operations are expected.
    [Show full text]
  • Lab Note #105 — Rev A
    7900 INTERNATIONAL DRIVE, SUITE 200, BLOOMINGTON, MN 55425 // 612-928-5546 www.ArcSuppressionTechnologies.com arc suppression! technologies Contact Life ! Unsuppressed vs. Suppressed Arcing ! Lab Note #105 — rev A ABSTRACT Electric current arcing causes significant degradation of the contacts in electromechanical relays and contactors. This contact degradation drastically limits the overall life of a relay or contactor to a range of perhaps 10,000 to 100,000 operations … a level far below the mechanical life of the same device, which can be in excess of 20 million operations. Product designers, technicians and engineers are all trained to believe that a snubber connected across the contacts of a relay will reduce or eliminate the arcing. Snubbers do not measure up to the claim of being arc suppressors. PROBLEM Product designers, technicians and engineers are all trained to accept specifications when selecting electromechanical relays and contactors. None of these specifications, however, indicate the impact of electrical arcing on contact life expectancy. TESTS Operate a Tyco T90 open-frame relay switching a resistive load at 240Vac, 5kW, 1 second cycle time, 50% duty cycle, under three separate test conditions: I. With no suppression element II. With a typical RC Snubber (ITW QuenchArc, 0.1µF+200") connected across the relay contacts III. With a NOsparc MMXac™ arc suppressor connected across the relay contacts The QuenchArc was selected as representative of RC snubbers. The relays were run at the above duty cycle up to 100,000 cycles (or failure, if that came first). Fig 1. is a diagram of a typical contact protection arrangement without arc suppression.
    [Show full text]
  • Electrical Arc Contents
    Electrical Arc Contents 1 Electric arc 1 1.1 History ................................................. 1 1.2 Overview ............................................... 1 1.3 Uses .................................................. 2 1.4 Undesired arcing ............................................ 3 1.5 Arc suppression ............................................ 4 1.6 See also ................................................ 4 1.7 References ............................................... 4 1.8 External links ............................................. 4 2 Vacuum arc 5 2.1 References ............................................... 5 2.2 See also ................................................ 5 3 Cathodic arc deposition 6 3.1 History ................................................. 6 3.2 Process ................................................ 6 3.3 Equipment design ........................................... 6 3.4 Applications .............................................. 7 3.5 See also ................................................ 7 3.6 References ............................................... 8 4 Glow discharge 9 4.1 Basic operating mechanism ...................................... 9 4.2 Use in analytical chemistry ...................................... 10 4.3 Powering modes ............................................ 11 4.4 Types ................................................. 11 4.5 Application to analog computing ................................... 11 4.6 See also ................................................ 11 4.7 References
    [Show full text]