Sophomore Laboratory Manual
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Laboratory Glassware N Edition No
Laboratory Glassware n Edition No. 2 n Index Introduction 3 Ground joint glassware 13 Volumetric glassware 53 General laboratory glassware 65 Alphabetical index 76 Índice alfabético 77 Index Reference index 78 [email protected] Scharlau has been in the scientific glassware business for over 15 years Until now Scharlab S.L. had limited its sales to the Spanish market. However, now, coinciding with the inauguration of the new workshop next to our warehouse in Sentmenat, we are ready to export our scientific glassware to other countries. Standard and made to order Products for which there is regular demand are produced in larger Scharlau glassware quantities and then stocked for almost immediate supply. Other products are either manufactured directly from glass tubing or are constructed from a number of semi-finished products. Quality Even today, scientific glassblowing remains a highly skilled hand craft and the quality of glassware depends on the skill of each blower. Careful selection of the raw glass ensures that our final products are free from imperfections such as air lines, scratches and stones. You will be able to judge for yourself the workmanship of our glassware products. Safety All our glassware is annealed and made stress free to avoid breakage. Fax: +34 93 715 67 25 Scharlab The Lab Sourcing Group 3 www.scharlab.com Glassware Scharlau glassware is made from borosilicate glass that meets the specifications of the following standards: BS ISO 3585, DIN 12217 Type 3.3 Borosilicate glass ASTM E-438 Type 1 Class A Borosilicate glass US Pharmacopoeia Type 1 Borosilicate glass European Pharmacopoeia Type 1 Glass The typical chemical composition of our borosilicate glass is as follows: O Si 2 81% B2O3 13% Na2O 4% Al2O3 2% Glass is an inorganic substance that on cooling becomes rigid without crystallising and therefore it has no melting point as such. -
Standard Operating Procedures
Standard Operating Procedures 1 Standard Operating Procedures OVERVIEW In the following laboratory exercises you will be introduced to some of the glassware and tech- niques used by chemists to isolate components from natural or synthetic mixtures and to purify the individual compounds and characterize them by determining some of their physical proper- ties. While working collaboratively with your group members you will become acquainted with: a) Volumetric glassware b) Liquid-liquid extraction apparatus c) Distillation apparatus OBJECTIVES After finishing these sessions and reporting your results to your mentor, you should be able to: • Prepare solutions of exact concentrations • Separate liquid-liquid mixtures • Purify compounds by recrystallization • Separate mixtures by simple and fractional distillation 2 EXPERIMENT 1 Glassware Calibration, Primary and Secondary Standards, and Manual Titrations PART 1. Volumetric Glassware Calibration Volumetric glassware is used to either contain or deliver liquids at a specified temperature. Glassware manufacturers indicate this by inscribing on the volumetric ware the initials TC (to contain) or TD (to deliver) along with the calibration temperature, which is usually 20°C1. Volumetric glassware must be scrupulously clean before use. The presence of streaks or droplets is an indication of the presence of a grease film. To eliminate grease from glassware, scrub with detergent solution, rinse with tap water, and finally rinse with a small portion of distilled water. Volumetric flasks (TC) A volumetric flask has a large round bottom with only one graduation mark positioned on the long narrow neck. Graduation Mark Stopper The position of the mark facilitates the accurate and precise reading of the meniscus. If the flask is used to prepare a solution starting with a solid compound, add small amounts of sol- vent until the entire solid dissolves. -
Gravimetric Analysis of Chloride
Chemistry 321L Manual Page 16 Gravimetric Analysis of Chloride I. Introduction The amount of chloride ion in a substance can be determined by precipitating the soluble chloride ion present with silver ion. The amount of chloride ion present will be related to the mass of silver chloride formed. + - Ag (aq) + Cl (aq) 6 AgCl (s) II. Procedure A. Preparation of Filter Crucibles (Sintered-Glass) 1. Use four filter crucibles of medium (M) porosity. Do not use crucibles marked C for coarse porosity. 2. Previously, the crucibles have been used to filter silver chloride (purple or gray, ammonia soluble). First, remove any bulk precipitate with a rubber policeman and dispose of it in a "Silver Collection" jar. Follow this with chemical cleaning. To remove silver chloride, invert the crucibles in a large beaker in a fume hood and add one or two mL of concentrated ammonia to each. Allow to soak until clean. Carefully remove the crucibles from the beaker and soak in water before removing from the fume hood. Set up a suction filtration apparatus and wash the crucible several times with water and finally with deionized water. Empty the suction flask before proceeding. Stains that are not removed by this cleaning process should not interfere with your measurements. Number, in pencil, each crucible on the frosted glass area. 3. Dry the crucibles in an oven at 120EC for about 1 hour, using a beaker, glass hooks, and watch glass (see figure). A ribbed watch glass can be used in place of the glass hooks. 4. Remove the dried crucibles from the oven and let them cool for about one minute on the counter top. -
LAB: One Tube Reaction Part 1
AP Chemistry LAB: One Tube Reaction Part 1 Objective: To monitor and document the chemical changes occurring in a single test tube containing a predetermined mixture of chemicals. Materials: test tube, iron nail, sodium chloride, copper (II) sulfate, distilled water, glass stirring rod, tissue paper, parafilm wax Procedures: 1. Label a test tube to identify your group 2. Fill approx. 1/3 of the test tube with copper (II) sulfate crystals. Gently tap the tube to allow the crystals to settle. 3. Using a glass stirring rod, carefully cover the crystals with a layer of Kimwipe tissue paper. 4. Slowly, and with as little disturbance as possible, add enough distilled water to just cover the paper and blue crystals. 5. Repeat the process for the sodium chloride, filling approx. 1/3 of the test tube. Gently tap the tube to allow the crystals to settle. 6. Push more tissue paper into the test tube on top of the white crystals. 7. Add enough water to cover the tissue paper and white crystals. 8. Obtain an iron nail and expose the surface by rubbing with sand paper. 9. Carefully slide the nail into the test tube. 10. Continue adding water until the nail is completely covered. 11. Cover the test tube with parafilm wax and record your Day 1 observations. 12. Return the test tube to the test tube rack. 13. Continue to monitor and record your observations for the next several days, as indicated in the data table. Data: 1. Complete the NFPA label for the two chemicals used in this lab. -
Electrowinning of Tellurium by Means of PLS Modelling
2009:056 MASTER'S THESIS Optimisation of Influential Factors in Electrowinning of Tellurium by Means of PLS Modelling Seyed Mohammad Khosh Khoo Sany Luleå University of Technology Master Thesis, Continuation Courses Minerals and Metallurgical Engineering Department of Chemical Engineering and Geosciences Division of Process Metallurgy 2009:056 - ISSN: 1653-0187 - ISRN: LTU-PB-EX--09/056--SE Optimisation of Influential Factors in Electrowinning of Tellurium by Means of PLS Modelling Master Thesis By: Seyed Mohammad Khoshkhoo Sany [email protected] Supervisors: Prof. Åke Sandström (Luleå University of Technology) Dr. Nils Johan Bolin (Boliden Mineral AB) Abstract Electrowinning of tellurium is a relatively simple process that can be carried out effectively by employing the existing technology. In order to obtain tellurium with the least amount of impurities, the effects of three main factors were studied, namely current density, free concentration of caustic soda and initial concentration of tellurium. Five elements were chosen as the main impurities: Ag, Bi, Cd, Ni and Pb. A series of 17 experiments arranged in a CCF (central composite faced-centred) design has been carried out and the results were fitted using PLS (partial least squares) method. The effect of free caustic concentration was found to be the most important of the three parameters studied. Current density was also important, yielding the least amount of impurities at high current densities. Tellurium concentration had the smallest effect of the three parameters studied. From the model, current densities of 330-350 A/m2, tellurium concentrations of 90-120 g/l and free sodium hydroxide concentration of around 120 g/l are suggested as optimal conditions for obtaining the purest tellurium. -
SC-300 Pro Kit Manual 1 Version 2.3D Materials Provided in the Kit
Vinmetrica SC-300 Pro Kit™ User Manual Vinmetrica SC-300 Pro Kit is a simple and robust device that provides high accuracy in determination of sulfite (SO2), pH and titratable acidity (TA) levels in wines, ciders, and other liquids. These are essential parameters to control in the effort to make high quality wines. The Pro kit includes lab accessories for the SC-300 Analyzer. Table of Contents: Materials Provided in the Kit............................................................................................................... 2 Things you will need............................................................................................................................ 2 Why Test for SO2, pH and TA?............................................................................................................ 3 Theory of Operation............................................................................................................................. 4 Setup.................................................................................................................................................... 5 Setting up the SC-300 for the first time................................................................................... 5 Assembling the Pro Kit Equipment......................................................................................... 6 Burette Maintenance................................................................................................................ 8 Burette Reading ...................................................................................................................... -
Equipment Detailsr07
Lab Equipment Details Lab Equipment Glass Flasks 150ml 250ml 500ml Lab Equipment Glass Beakers 150ml 250ml 500ml Lab Equipment Glassware But once removed, only the cap stays highlighted. Droppers critical to Lab An activated Dropper coursework can be found highlights the entire bottle. already in the workspace. Dropper Dropper Dropper Activated In Use Lab Equipment Gastight Syringe Small A pre-filled gastight syringe can be used with a NMR tube to safely fill through the top in preparation for use with the NMR spectrometer. Gastight Syringe NMR Tube with Holder with Holder Lab Equipment NMR Tube Spinner An NMR Tube filled with gas for use with the NMR Spectrometer Simply use the NMR Tube with needs to be inserted into the the Tube Spinner. Spinner before it can be used. NMR Tube NMR Tube Spinner NMR Tube Spinner with Holder with NMR Tube inserted Once the Tube slotted into the holder is inserted into the top part of the spectrometer, users can type in a number for Lab Equipment the frequency they’d like to scan. NMR Spectrometer XL The NMR Tube holder can then be slotted into the highlighted tube on the NMR Spectrometer. NMR Tube filled with appropriate substance is slotted (used with) in the holder. Lift will perpare the Spectrometer for the tube holder insertion. Scan No. Allows the user to change the frequency at which the tube is scanned The NMR Tube holder can then be slotted into the top tube on Lab Equipment the NMR Spectrometer. NMR Spectrometer XL NMR Tube filled with appropriate substance is slotted (used with) in the holder. -
EXPERIMENT 15 TF Notes
EXPERIMENT 15 TF Notes 1. Have students log onto LoggerPro3 and start heating water as soon as they arrive 2. This reaction is easily contaminated so students must never insert the thermometer directly into the cuvette containing the reaction. Instead they should rather measure the temperature of the water and equate that to the temperature of the solution in the cuvette. 3. We will be using hot gloves in this experiment. 4. Make sure you are familiar with the calculations necessary to fill out the chart. All the necessary equations are given at the top fo the page. Note that the temperature must be converted from °C to K. EXPERIMENT 15 Thermodynamics of Complex-Ion Equilibria Introduction Thermodynamic data for a reaction system provides researchers with information that is important from both theoretical and practical points of view. There are several thermodynamic properties that chemists pay close attention to when designing or carrying out experiments such as thermodynamic stability, the change in free energy of a reaction, and temperature dependence. For example, if a chemist wants to create a new type of solar cell that combines a semiconductor material with a novel conductive oxide and wants to make sure that the two materials will not react with each other, thermodynamics provide the answer. By finding the free energy change associated with the reaction, s/he can determine how stable the layers are in contact with each other and to what temperature. In this experiment, you will learn how to determine those parameters from a controlled experiment by using spectrometry to find concentration data at various temperatures. -
General Chemistry Laboratory I Manual
GENERAL CHEMISTRY LABORATORY I MANUAL Fall Semester Contents Laboratory Equipments .............................................................................................................................. i Experiment 1 Measurements and Density .............................................................................................. 10 Experiment 2 The Stoichiometry of a Reaction ..................................................................................... 31 Experiment 3 Titration of Acids and Bases ............................................................................................ 10 Experiment 4 Oxidation – Reduction Titration ..................................................................................... 49 Experiment 5 Quantitative Analysis Based on Gas Properties ............................................................ 57 Experiment 6 Thermochemistry: The Heat of Reaction ....................................................................... 67 Experiment 7 Group I: The Soluble Group ........................................................................................... 79 Experiment 8 Gravimetric Analysis ........................................................................................................ 84 Scores of the General Chemistry Laboratory I Experiments ............................................................... 93 LABORATORY EQUIPMENTS BEAKER (BEHER) Beakers are containers which can be used for carrying out reactions, heating solutions, and for water baths. They are for -
Laboratory Equipment Reference Sheet
Laboratory Equipment Stirring Rod: Reference Sheet: Iron Ring: Description: Glass rod. Uses: To stir combinations; To use in pouring liquids. Evaporating Dish: Description: Iron ring with a screw fastener; Several Sizes Uses: To fasten to the ring stand as a support for an apparatus Description: Porcelain dish. Buret Clamp/Test Tube Clamp: Uses: As a container for small amounts of liquids being evaporated. Glass Plate: Description: Metal clamp with a screw fastener, swivel and lock nut, adjusting screw, and a curved clamp. Uses: To hold an apparatus; May be fastened to a ring stand. Mortar and Pestle: Description: Thick glass. Uses: Many uses; Should not be heated Description: Heavy porcelain dish with a grinder. Watch Glass: Uses: To grind chemicals to a powder. Spatula: Description: Curved glass. Uses: May be used as a beaker cover; May be used in evaporating very small amounts of Description: Made of metal or porcelain. liquid. Uses: To transfer solid chemicals in weighing. Funnel: Triangular File: Description: Metal file with three cutting edges. Uses: To scratch glass or file. Rubber Connector: Description: Glass or plastic. Uses: To hold filter paper; May be used in pouring Description: Short length of tubing. Medicine Dropper: Uses: To connect parts of an apparatus. Pinch Clamp: Description: Glass tip with a rubber bulb. Uses: To transfer small amounts of liquid. Forceps: Description: Metal clamp with finger grips. Uses: To clamp a rubber connector. Test Tube Rack: Description: Metal Uses: To pick up or hold small objects. Beaker: Description: Rack; May be wood, metal, or plastic. Uses: To hold test tubes in an upright position. -
Thermal Activity of Base Course Material Related to Pavement Cracking
THERMAL ACTIVITY OF BASE COURSE MATERIAL RELATED TO PAVEMENT CRACKING by Samuel H. Carpenter Robert L. Lytton Research Report Number 18-2 Environmental Deterioration of Pavement Research Project 2-8-73-18 Conducted for the State Department of Highways and Public Transportation in cooperation with the U.S. Department of Transportation Federal Highway Administration by the Texas Transportation Institute Texas A&M Univeristy College station, Texas December, 197 5 TECHNICAL REPORT STANDARD TITLE PACf 1. Report No. 2. Government Accession No. 3. Recipient's Catalog No. ~4.-;Ti~tl-e-an~d~Su~b~ti~tle------------~------------------------~S~.~R~e-pa-rt~D~at_e _________________ _ Thermal Activity of Base Course Material Related to December. 1975 Pavement Cracking 6. Performing Organi •ation Code 7. Authorl s) 8. Performing Organi •ation Report No. Samuel H. Carpenter and Robert L. Lytton Research Report No. 18-2 9. Performing Organi !at ion Name and Address 10. Work Unit Na. Texas Transportation Institute Texas A&M University 11. Contract or Grant No. College Station, Texas 77843 Study No. 2-8-73-18 13. Type of Report and Period Covered ~~----------------~--------------------------~12. Sponsoring 'Agency Name and Address Texas State Department of Highways and Public Trans Inter'm1 _ September, 1972 portation; Transportation Planning Division December, 1975 P. 0. Box 5051 14. Sponsoring Agency Code Austin, Texas 78763 15. Supplementary Notes Research performed in cooperation with DOT, FHWA. Study Title: 11 Environmental Deterioration of Pavement 11 16. Abstract Preliminary studies into environmental deterioration of pavements indicated that low-temperature cracking of the asphalt concrete surface was not likely for the west Texas area. -
The Magic Motion
The Magic Motion www.wiggens.com Rotary Evaporators Pumps Stirrers Heating Shakers Homogenizers Incubators Gas Generators About WIGGENS Wiggens was established in 2005 with the goal delivering the best laboratory equipment and service for reliable results, since then Wiggens has been producing top-quality general laboratory equipment, our brand Wiggens stands for high quality, durability and remarkable performance. Wiggens is your general laboratory companion and provides products that can be used in all kinds of laboratory environments. The Wiggens product range entails an extensive range of magnetic stirrers, heating mantles and dry baths. Advanced infrared hot plates with integrated stirring functions for an even heat distribution among your solvents are also available, in addition Wiggens also provides overhead stirrers with diverse characteristics to perfectly match the laboratory stirring and blending requirements. A complete range of new products in 2017 including homogenizers of different magnitudes as well as a broad range of shakers, multi-purpose heaters, colony counters. incubators, ovens and shaking incubators for full temperature control. ChemVak is your brand specializing in vacuum technology offering an extensive range of vacuum pumps for all applications, including chemical-resistant diaphragm pumps and oil-free piston pumps, are complemented by vacuum filtration equipment for a wide range of different applications. In addition, water-jet aspirator pumps and bio-suction systems are part of the product range. In 2017, Wiggens launched its whole range gas generators with Vgas product band, the new Vgas product line rounds out our product solutions as a specialist in vacuum and gas related operations. ChemTron is your brand for chemical reaction solutions, Biotron for highly qualified bio-equipment and Vdose specialized in liquid handling pumps, completes the range of brands within the Wiggens family.