Technical

Lateral torsional and slenderness

The expression for slenderness used in the lateral torsional buckling checks given in BSEN1993-1-1:2005 is different to that given in BS5950-1:2000. Mary Brettle, Senior Engineer at the Steel Construction Institute, examines lateral torsional buckling and shows how both slenderness expressions are based on the same elastic critical theory.

1. WHAT IS LATERAL TORSIONAL BUCKLING? flanges. This is why Table 20 of BS5950-1:2000 relates the value Lateral torsional of pb to the ratio of depth / flange thickness D/T( ) and Table 7 of buckling may occur in an BS449-2:1969 relates the value of elastic critical (Cs) to D/T. unrestrained . A beam is considered to 1.3 What affects lateral torsional buckling be unrestrained when its Some factors that influence the lateral torsional buckling compression flange is free behaviour of beams are briefly discussed below: to displace laterally and rotate. When an applied Location of the applied load load causes both lateral The vertical distance between the load application point and displacement and twisting the shear centre of the section affects the susceptibility of the of a member lateral Figure 1 section to the effects of lateral torsional buckling. If the load torsional buckling has is applied at a location above the shear centre of a section it is occurred. Figure 1 shows more susceptible to lateral torsional buckling than if the load was the lateral displacement and twisting experienced by a beam applied through the shear centre. Applying the load at a location when lateral torsional buckling occurs. below the shear centre of a section reduces the susceptibility of the section to the effects of lateral torsional buckling. When 1.1 What causes the lateral ? the load is applied above the shear centre it is known as a The applied vertical load destabilising load, with loads applied at or below the shear results in compression centre called non-destabilising loads. The effect of a destabilising and tension in the flanges load is considered by the use of effective lengths given in Table of the section. The 13 of BS5950-1:2000, where the effective lengths are longer for compression flange tries destabilising loads compared to the non-destabilising loads. to deflect laterally away from its original position, The shape of the applied moment whereas the tension The buckling resistance for a section subject to a uniform flange tries to keep the bending moment distribution along its length is less than the member straight. The buckling resistance obtained for the same section subjected to lateral movement of a different bending moment distribution. Factors are included the flanges is shown in in design guidance to allow for the effect of different bending Figure 2. moment distributions. UK designers will be familiar with the use The lateral bending of the equivalent uniform moment factor (m ) in BS5950-1:2000. Figure 2 LT of the section creates restoring that oppose the movement because the section End support conditions wants to remain straight. These restoring forces are not large The end support conditions considered during the development enough to stop the section from deflecting laterally, but together of the basic theory for buckling moments are equivalent to with the lateral component of the tensile forces, they determine web cleats that stop the web from deflecting laterally and the buckling resistance of the beam. twisting. For end conditions where more restraint is given to the section the buckling moment increases, with the buckling 1.2 Torsional effect moment decreasing for end supports that offer less restraint In addition to the lateral movement of the section the to the section. BS5950-1:2000 considers effective lengths when forces within the flanges cause the section to twist about its determining the slenderness of a section to account for the effect longitudinal axis as shown in Figure 3. The twisting is resisted of end restraint on lateral torsional buckling. by the torsional stiffness of the section. The torsional stiffness of a section is dominated by the flange thickness. That is why 2. SECTION SLENDERNESS a section with The slenderness of a section is used in design checks for lateral thicker flanges has torsional buckling. The following factors affect the slenderness of a larger bending a section: strength (pb) than • Length of the beam the same depth of Figure 3 • Lateral bending stiffness of the flanges section with thinner • Torsional stiffness of the section

30 NSC October 2006 Technical

Design codes need to account for the above factors in the guidance they give for determining the slenderness of a section.

The elastic critical moment (Mcr) is used as the basis for the methods given in design codes for determining the slenderness BS5400-3:2000 of a section. The elastic critical moment (Mcr) is similar to the The guidance given in this British Standard for overall lateral

Euler (flexural) buckling of a strut in that it defines a buckling buckling given in clause 9.7.5 explicitly uses Mcr as follows: load. Euler bucking defines the axial compression that will cause a strut to fail in elastic flexural buckling compared with the elastic critical moment that defines the moment that will result in failure due to elastic lateral torsional buckling of a beam. The Elastic Where: critical buckling (Mcr) and Euler buckling (PE) curves are shown in Zpe is defined in 9.7.1 as Figure 4. The buckling moment of a section 3. EUROCODE 3 DESIGN is affected by The lateral torsional buckling design guidance given in plasticity. Therefore BSEN1993-1-1:2005 requires a reduction factor (cLT) to be applied the buckling to the moment resistance of the cross section to give the lateral moment resistance torsional buckling moment resistance (Mb,Rd). cLT is determined

(Mb) cannot be from a factor (FLT) and the non-dimensional slenderness factor greater than the (lLT). The expression given for lLT is: plastic moment (Mpl) of the section. The buckling moment resistance curve Where: Figure 4 shown in Figure 4 Wy ƒy is the moment resistance for the section (Mb,Rd), which is shows that; equivalent to Mc in BS5950-1:2000. • very slender sections fail elastically by excessive lateral

torsional buckling at an applied moment close to Mcr, 3.1 Calculating Mcr

• intermediate slender sections fail inelastically by excessive For doubly symmetric sections the expression for Mcr is:

lateral torsional buckling at applied moments less than Mcr,

• stocky sections will attain their full plastic moment (Mpl) with negligible lateral torsional buckling. Where

2.1 How British Standards use the elastic critical moment (Mcr) E is the Youngs modulus

British Standard steel design codes all use Mcr as the basis for G is the shear modulus determining the slenderness of a section, but, the expressions Iz is the about the minor axis used in the codes are not the same. Below the expressions given It is the constant in some British Standards are considered. Iw is the warping constant L is the beam length between points which have lateral BS5950-1:2000 restraint

The expression given for uniform I, H and channel sections with k and kw are effective length factors equal flanges is: zg is the distance between the point of load application and the

The above expression does not appear to consider Mcr . shear centre (see Figure 5)

However, when the expressions given in Annex B of C1 and C2 are coefficients depending on the loading and BS5950-1:2000 are considered it can be shown how the above end restraint expression is based on Mcr. conditions.

Further details on the above

Where: calculation of Mcr can be found in the access Steel document SN003a,

βw is defined in 4.3.6.9 as where the design which is given on modulus depends on the classification of the cross section. the website: www.

Therefore, the expression for lLT can be rearranged to give: accesssteel.com. Figure 5

3.2 Don’t panic, you can determine lLT without Mcr

After seeing the above expression for Mcr for doubly symmetric

sections designers will be pleased to learn that lLT can be

BS449-2:1969 determined without having to calculate Mcr. From the formula for

The guidance given for bending stresses in plate girders uses the Mcr the following expression for rolled I, H and channel sections elastic critical stress (Cs) to determine the permissible bending with non-destabilising loads has been determined: stress (pbc). The elastic critical stress (Cs) can be expressed as: 34

32 NSC October 2006 Codes & Standards

New and Revised Codes and Standards (from BSI Updates July and August 2006)

BS EN PUBLICATIONS Technical delivery conditions for Design of joints 06/30128176 DC alloy steels AMD 16291 CORRIGENDUM 1 NA to BS EN 1994-2 The following are British Standard Supersedes BS EN 10083-3:1996 BS EN 1993-1-9:2005 National Annex to Eurocode 4. implementations of the English Fatigue Design of composite steel and language versions of European BS EN 10131:2006 AMD 16292 CORRIGENDUM 1 concrete structures. Part 2. General Standards (ENs). BSI has an Cold rolled uncoated and zinc or BS EN 1993-1-10:2005 rules and rules for buildings obligation to publish all ENs and zinc-nickel electrolytically coated Material toughness and to withdraw any conflicting British low carbon and high strength through-thickness properties Standards or parts of British steel flat products for cold forming. AMD 16293 CORRIGENDUM 1 CEN EUROPEAN Standard. This has led to a series Tolerances on dimensions and STANDARDS of standards, BS ENs using the EN shape BS EN 14399:- number. Supersedes BS EN 10131:1991 High-strength structural bolting EN 1991:- Note: The date referenced in the assemblies for preloading Eurocode 1: Actions on structures identifier is the date of the European BS EN 10140:2006 BS EN 14399-5:2005 EN 1991-1:- standard. Cold rolled narrow steel strip. Plain washers General actions Tolerances on dimensions and AMD 16228 CORRIGENDUM 1 EN 1991-1-7:2006 BS EN ISO 9445:2006 shape BS EN 14399-6:2005 Accidental actions Continuously cold-rolled stainless Supersedes BS EN 10140:1997 Plain chamfered washers EN 1991-3:2006 steel narrow strip, wide strip, plate/ AMD 16229 CORRIGENDUM 1 Actions induced by cranes sheet and cut lengths. Tolerances and machinery on dimensions and form. AMENDMENTS TO Supersedes BS EN 10258:1997 and BRITISH STANDARDS DRAFT BRITISH EN 10083:- BS EN 10259:1997 STANDARDS FOR PUBLIC Steels for quenching and tempering BS EN 1993:- COMMENT EN 10083-1:2006 BS EN 10083:- Eurocode 3: Design of steel General technical delivery Steels for quenching and tempering structures 06/19976125 DC conditions BS EN 10083-2:2006 BS EN 1993-1-2:2005 BS ISO 15653 Technical delivery conditions for General rules. Structural fire Metallic materials. Method of test EN 10268:2006 non alloy steels design for the determination of fracture Cold rolled steel flat products with Supersedes BS EN 10083-2:1991 AMD 16290 CORRIGENDUM 1 toughness of welds. high yield strength for cold forming. BS EN 10083-3:2006 BS EN 1993-1-8:2005 Technical delivery conditions

Buy any BSI Standard from the SCI at 20% discount Contact Publications Sales: T: 01344 636505 F: 01344 636570 Email: [email protected]

Lateral torsional buckling and slenderness Continued from page 32

iz is the radius of gyration about the minor axis

Where:

is a parameter dependant on the shape of the bending ƒy is the yield strength of the steel moment diagram, values can be obtained from access Steel

document SN002a and the forthcoming SCI / Corus Concise Wy is the plastic, elastic or effective section modulus (depending Guide to Eurocode 3. on the section classification)

Wpl,y is the plastic section modulus.

L is the distance between points of lateral restraint

34 NSC October 2006