Float Switches Class 9036 – Types D and G
Total Page:16
File Type:pdf, Size:1020Kb
Float Switches Class 9036 – Types D and G For Open Tank Or Sump Applications Class 9036 2 Pole Single Lever Operated NEMA Type 1 NEMA Type 4 NEMA Type 7, 9 Description Type Price Type Price Type Price Contacts Close on Liquid Rise. DG2 $35.60 DW31 $236. DR31 $227. Contacts Open on Liquid Rise . DG2R 38.80 DW31R 239. DR31R 230. Contacts Close on Liquid Rise. GG2 68.00 GW1 397. GR1 388. Contacts Open on Liquid Rise . GG2R 68.00 GW1R 404. GR1R 397. Order universal mounting bracket and float accessory kits separately from Class 9049 section. Types GW and GR use center hole float. Devices with Form C use Centerhole float . All others use tapped at top float. See Page 18-8 for 9049 accessories. Modifications For Type DG, DW, DR Factory Installed Field Installed Form Price 9049 Kit Price Reverse Action (Type DG) R $3.30 A58 $3.30 Compensating Spring (Type DG) C 6.50 A19 6.50 Compensating Spring (Type DR, DW) C 6.50 A20 6.50 Type DG2 Comp. Spring and Reverse Action CR 9.80 Not Available Modifications For Type GG, GW, GR Factory Installed Field Installed Form Price 9049 Kit Price Compensating Spring for Type GG2 C 8.10 9049A13 8.10 Combination of Comp. Spring & Reverse Action (Type GG2) CR 17.70 9049A13 8.10 1 N.O.-1 N.C. Contact Configuration H 9.60 Not Available Combination of Comp. Spring & 1 N.O.-1 N. C. Contact for Type GG2 CH 17.70 Not Available Reverse Action (Type GR, GW) R 9.60 Not Available Maximum Forces At Which Switches Are Tested (in ounces) Type Force Up Force Down Will Support This Weight To Trip To Trip With Compensating Spring Type GG DG2 9 8 60 DG2 Form R 8 8 60 DW31 8 8 66 DW31 Form R 8 8 66 DR31 8 8 66 DR31 Form R 8 8 66 Class 9049 Float Accessory Specifications – In Ounces Item Type A6 Type A6S Type A6C Type A6CS Type A6A Type A6CA Net Buoyancya (in Water) 7" Float . 60 c 60 c 70 c 70 c 60 c 70 c Weight of 5 foot rod . 18.5 16.9 18.5 16.9 6 6 Weight of Extra Ft. of rod (Per Ft.) . 3.7 3.4 3.7 3.4 1.2 1.2 Total Weight of Stops . 3 (2) 3 (2) 6 (4) 6 (4) 3 (2) 6 (4) cNet Buoyancy of float has been calculated with float 80% submerged, thus allowing 20% factor of safety. aBuoyancy data above is calculated for use in water. Consult factory for buoyancy data media having specific gravity different than water. When ordering Float Accessories, first specify the desired Float Accessory Package such as 9049 A-6, 9049 A-6CS, etc., then as a second item give the number of additional rod Kits required. For Example: To get a 9049 A-6 with 15 feet of rod, order as follows: Item A (1) 9049A6 Item B (4) 9049T1 Refer to page 20-8 for Float Accessories. Type (with or without Lever Length Force Up Force Down Will Support This Weight With FORM H) POSITION to Trip to Trip Compensating Spring at Max. Adj. in Ozs. GG2 Short 33 39 q GG2 Long 21 27 100 GG2 Form R Short 30 24 q GG2 Form R Long 22 16 150 GR1, GW1 Short 24 31 80 GR1, GW1 Medium 22 29 72 GR1, GW1 Long 20 27 64 qCompensating Spring not effective in combination with SHORT Lever length position. PRESSURE, VAC, TEMP AND FLOAT SWITCHES 20 For additional information, reference catalog number 9034CT9701 or D-Fax™ number 1571, 1572, 1573. © 2000 Square D CP7G Discount 20-22 All Rights Reserved Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Sump Pump Float Switches Type FG and LG – Sumptrol® Sump Pump Float Switch – Class 9036 The Class 9036 Type FG-30 pedestal style float switch is designed for liquid level control with electric motor operated pumps either directly or through a magnetic starter. It can also be used to activate alarms in liquid level control system s. The upward of downward movement of the lever arm of the Class 9036 Type FG-30 float switch controls the ON and OFF positions corresponding to the water levels changes required to turn the pump or alarm on and off. Description Type Price Contacts close on liquid rise FG-30 2 pole NEMA Type 1 $15.00 Accessories Description Number Required Class Type Price Plastic center hole float 1 9049 A60 $ 4.00 33.75 inch aluminum rod, 2 float stop assemblies and attaching hardw are 1 9049 A61 4.00 Type FG The Class 9036 Type LG float switch automatically controls submersible sump, effluent and sewage pumps either directly or through a magnetic starter. It can also be used to activate alarms in water or sewage systems. The Type LG is a universal replacement for most small sump, effluent and sewage pump float switches. This float switch does NOT contain mercury. The Type LG is omnidirectional and functions properly regardless of orientation. Electrical Ratings Voltage Unterminated Rating Plug Rating Recommended Single Phase Maximum Horsepower 1 120Vac, 50/60 Hz 15 Amps 12 Amps /2 HP max. 230Vac, 50/60Hz 15 Amps 12 Amps 1 HP max. Type LG Electrical Contacts: Snap action, normally open Differential Angle: 85 degrees +/- 10 degrees Housing Material: Polypropylene 3.01 76 Temperature Range: Ambient Operating: +32˚F to +140˚F (0˚C to +60˚C) Storage: -40˚F to +185˚F (-40˚C to +85˚C) Dimensions: 3.01 in. (76.4 mm) diameter 4.85 5.10 in. (130 mm) length 123 (APPROX.) Cord: #16 AWG, 2 conductor, SJOW-A, flexible cord, water resistant to 140˚F (60˚C) Maximum Tether Length: 36 inches Description Price 0.32 8 9036LG1120B, 115 Vac Plug, 10 feet of cord $37.30 9036LG1120C, 230 Vac Plug, 10 feet of cord 37.30 Cord per foot 1.00 Without plug deduct 6.20 Type Numbering Codes: Class 9036 Type LG X XXX X XXX 1.Basic Type: LG 2.Contact Arrangement: one digit Type LG1 For pump down 3.Cord Length: three digits applications 4.Cord Termination: one letter 5.Packaging: up to three digits Contacts Closed 1.Basic Type: LG 2.Contact Arrangement :. 1 — Normally Open (for pump down or high level alarm) 2 — Normally Closed (for pump up or low level alarm) 3 — Normally Open control circuit rated. 3.Cord Length: In inches (up to 20 feet), eg. 12 indicates 12 inches of cord Contacts Open 4.Cord Termination: A = Bare wires B = 115 Vac Piggyback plug C = 230 Vac Piggyback plug PRESSURE, VAC, TEMP AND FLOAT SWITCHES 5.Packaging: C20 for bulk of 20 pieces 20 File E149970CCN REUZ2 File LR78493 Class 321106 For additional information, reference catalog number 9034CT9701 or D-Fax™ number 1571, 1572, 1573. CP7G Discount © 2000 Square D 3/00 Schedule All Rights Reserved 20-23 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Float Switches Class 9037 – Types D and E – Closed Tank Type D switches are completely self-contained units composed of switch mechanism, mounting flange, center hole float, and float rod. Class 9037 Type D Contacts Close On Liquid Rise Ground Link Length NEMA Type 1 NEMA Type 4 NEMA Type 7 and 9 “A” Distance Type Price Type Price Type Price 17" DG1 $335. DW1 $537. DR-1 $528. 3.5 23" DG2 353. DW2 555. DR2 543. 88.9 29" DG3 368. DW3 570. DR3 561. 35" DG4 385. DW4 587. DR4 576. 41" DG5 401. DW5 602. DR5 593. B 47" DG6 416. DW6 618. DR6 609. A 53" DG7 434. DW7 635. DR7 624. 59" DG8 449. DW8 651. DR8 642. 5.5 Available Factory Modifications 139.7 Note: Standard materials are: Float: #304 S.S. Float Guide Rod: #316 S.S. 4356-C1 Ground Post and Cross Tie: Brass Stop Collars : Brass Omit Float and Rod Accessories . Form L1 . deduct . $51.50 Omit Rod Accessories . Form L2 . deduct . 10.30 NOTE:The Cut-in point cannot be adjusted to less than 1 Reverse action, Contacts open on liquid rise. Form R . add . 20.70 3 /2" from the top of the tank. 1 The Cut-out point cannot be less than 5 /2" plus the #316 stainless steel Float and rod distance from the end of the ground link to the accessories . Form Z5 bottom of the tank. “A” distance. 17". add . 182.00 23". add . 193.00 29". add . 204.00 Mounting Dimensions for 35". add . 213.00 Class 9037 Types D and E 41". add . 224.00 47". add . 233.00 53". add . 245.00 59". add . 255.00 5.75 Dia. t 146 Table Of Adjustment In Inches 5.125 B.C. 130.18 4.41 “B” 112.02 “A” Approx. Water Level Change 0.125 Bead Type 3.18 Link Length Minimum Maximum 1 DG1 17" 3 /2"8" 1 (4) 0.41 Dia. DG2 23" 3 /2" 14" 10.4 Holes 1 DG3 29" 3 /2" 20" 1 DG4 35" 3 /2" 26" 1 DG5 41" 3 /2" 32" 1 DG6 47" 3 /2" 38" 1 DG7 53" 3 /2" 44" 1 DG8 59" 3 /2" 50" t Type EG The travels listed above also apply to the NEMA Type 7 and 9 (DR) and NEMA Type 4 (DW) Versions.