Roof Window Size Comparison

Total Page:16

File Type:pdf, Size:1020Kb

Roof Window Size Comparison Roof Windows Roof Window Size Comparison keyliteroofwindows.com Comparison Chart Futuretherm Technology Height (mm) Width (mm) 550 660 780 940 1140 1340 01 03A 04A 07A 08A 09A Keylite CK02 N/A N/A N/A N/A N/A Velux 780 01 22 23 24 25 26 Fakro 02 03B 04 07B 08B 09 Keylite CK04 FK04 MK04 PK04 N/A UK04 Velux 980 02 03 05 15 N/A 12 Fakro 01C 03 05 07C 08 09C Keylite CK06 FK06 MK06 PK06 SK06 N/A Velux 1180 16 04 06 08 10 N/A Fakro 01F 03F 06 07F 08F 10 Keylite N/A FK08 MK08 PK08 SK08 UK08 Velux 1400 N/A N/A 07 09 11 N/A Fakro Keylite 1600 01G 03G 04G 07G 08G 09G Velux N/A N/A MK10 PK10 SK10 UK10 Fakro N/A N/A 13 N/A N/A N/A Centre Pivot Roof Windows Pine White Conservation Pine Conservation White Keylite CP WF-CP CW-CP CW-WF-CP Velux GGL GGU GGL SD5 GGU SD5 Fakro FTP-V FTU-V & PTP-V FTP-V/C PTP-V/C Top Hung / Fire Escape Pine White Conservation Pine Conservation White Keylite FE WF-FE CW-FE CW-WF-FE Velux GPL GPU GPL SD5 GPU SD5 FPP-V & FPU-V & FPP-V/C & FPU-V/C & Fakro FHP-V FHU-V FHP-V/C FHU-V/C Single Flashings Slate Tile Deep Plain Tile Conservation Conservation Conservation Conservation Corrugated Tile Slate Tile Plain Tie Deep Tile Keylite SRF TRF DTRF PTRF CWSRF CWTRF CWPTRF CWDTRF CRF (Recessed As Standard) Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Velux EDL/ EDN EDZ N/A EDW/ EDJ EDP/ N/A N/A EDN N/A N/A EDP N/A EDW EDJ ZWC EBL/ EBW/ EBP/ EKL EKW EKP Fakro EL N/A EZ N/A EH N/A EP N/A /C N/A /C N/A /C N/A /C N/A EE Combi Flashings 18mm Gap 100 mm Gap Slate Deep Tile Plain Tile Slate Deep Tile Plain Tile Keylite CSRF CTRF CPTRF CSRF CTRF CPTRF (Recessed As Standard) Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Velux EBL N/A EBW N/A EBP N/A EKL EKN EKW EKJ EKP N/A 0021B 0021B 0021B 0021E S0021E 0021E S0021E 0021E TWIN TWIN TWIN COU- COU- COU- PLED PLED PLED Fakro N/A N/A N/A N/A N/A N/A B2/1 N/A B2/1 N/A B2/1 N/A Bi-Lite Flashings Quad-Lite Flashings Slate Tile Slate Tile Keylite BLSRF BLTRF Keylite QLSRF QLTRF (Recessed As (Recessed As Standard) Standard) Standard Recessed Standard Recessed Standard Recessed Standard Recessed Velux EKL S0122 N/A EKW N/A Velux EKL S0222 N/A EKW S0222 N/A DUO S0122 QUATRO QUATRO DUO Fakro B2/2 N/A B2/2 N/A Fakro B1/2 N/A B1/2 N/A Enhanced Installation Thermal Collar Felt Collar Vapour Collar Keylite Integrated Thermal Collar as standard FC VC Velux BDX BFX BBX Fakro XWT XDP XDS Comparison Chart Futuretherm Technology Sunlites (350 Diamm) Sunlites (250 Diamm) Tile Slate Flat Roof Tile Slate Flat Roof Rigid Flexi Rigid Flexi Rigid Flexi Rigid Flexi Rigid Flexi Rigid Flexi Keylite SLR350 SLF350 SLR350 SLF350 SLR350 SLF350 SLR250 SLF250 SLR250 SLF250 SLR250 SLF250 (Specify TILE TILE SLATE SLATE FLAT FLAT TILE TILE SLATE SLATE FLAT FLAT roof type ROOF ROOF ROOF ROOF on order) Velux TWR TWF 014 TLR 014 TLF 014 N/A TCF 014 TWR TWF 010 TLR 010 TLF 010 N/A N/A 014 2010 2010 2010 0010 010 2010 2010 2010 2010 2010 Fakro SRT SLT SRT SLT SRT SLT SRT SLT SRT SLT SRT SLT Flat Roof Domes Fixed - Fixed - Electric - Electric - Access - Access - Smoke Smoke Clear Frosted Clear Frosted Clear Frosted Vent - Vent - Clear Frosted Keylite FRD FRD-FR FRD-PEK FRD-FR-PEK FRD-AH FRD-FR-AH FRD-AOV FRD-FR-AOV (Specify roof type on order) Velux CFP S00G CFP S00H CVP S02G CVP S02H CXP S04G CXPS04H CSP S10G CSP S10H Fakro DXC N/A DEC N/A N/A N/A N/A N/A Vertical Bi-Lite Tilt Only Tilt and Turn Slate Tile Slate Tile Single Double Triple Single Double Triple Single Double Triple Single Double Triple Keylite VBL - T DVBL - T TVBL - T VBL - T DVBL - T TVBL - T VBL - TT DVBL - TT TVBL - VBL - TT DVBL - TT TVBL - T T T T Velux VFE EFL VFE EFL VFE EFL VFE EFW VFE EFW VFE EFW N/A N/A N/A N/A N/A N/A 0012 0022B 0032B 0012 0022B 0032B Fakro BVP EUV- BVP EUV- BVP EUV- BVP BVP BVP BD(L/R) BD(L/R) BD(L/R) BD(L/R) BD(L/R) BD(L/R) (S/D/Tdepends L/B L/B L/B EUV/B EUV/B EUV/B EUV-L/B EUV-L/B EUV-L/B EUV/B EUV/B EUV/B on roofwin- dow flashing) Flat Roof Apex Flat Roof System Single Double Triple Single Combi Keylite FRX DFRX TFRX Keylite FRS CFRS Velux N/A N/A N/A Velux ECX 0000T N/A Fakro N/A N/A N/A Fakro EFW N/A Glazing Electric Kits Double Safety Triple Frosted Standard Premium Smoke Vent System Glazed Double Glazed Glazing Keylite SEK PEK SVK Velux N/A INTEGRAL GGL SD0L1 Keylite T HT KTG FR (..21U) (slate) / GGL Velux -50 -70/-60 -66/-62 -34 SD0W1 (tile) Fakro N/A ELECTRO FSP Fakro U3 L3/R1 U5/U6 01 keyliteroofwindows.com.
Recommended publications
  • BUILDING CONSTRUCTION NOTES.Pdf
    10/21/2014 BUILDING CONSTRUCTION RIO HONDO TRUCK ACADEMY Why do firefighters need to know about Building Construction???? We must understand Building Construction to help us understand the behavior of buildings under fire conditions. Having a fundamental knowledge of buildings is an essential component of the decisiondecision--makingmaking process in successful fireground operations. We have to realize that newer construction methods are not in harmony with fire suppression operations. According to NFPA 1001: Standard for FireFighter Professional Qualifications Firefighter 1 Level ––BasicBasic Construction of doors, windows, and walls and the operation of doors, windows, and locks ––IndicatorsIndicators of potential collapse or roof failure ––EffectsEffects of construction type and elapsed time under fire conditions on structural integrity 1 10/21/2014 NFPA 1001 Firefighter 2 Level ––DangerousDangerous building conditions created by fire and suppression activities ––IndicatorsIndicators of building collapse ––EffectsEffects of fire and suppression activities on wood, masonry, cast iron, steel, reinforced concrete, gypsum wallboard, glass and plaster on lath Money, Money, Money….. Everything comes down to MONEY, including building construction. As John Mittendorf says “ Although certain types of building construction are currently popular with architects, modern practices will be inevitably be replaced by newer, more efficient, more costcost--effectiveeffective methods ”” Considerations include: ––CostCost of Labor ––EquipmentEquipment
    [Show full text]
  • Geodesic Dome Roof
    GEODESIC DOME ROOF The HMT Geodesic Dome features a clear-span, all-aluminum, lightweight, corrosion-resistant structure which sets a new standard for performance in aluminum geodesic domes. HMT’s unique overlapping-panel design and attention to details at critical locations all result in a cost-effective solution that provides superior protection of your stored product. The HMT Geodesic Dome can be installed in-service and its superior design was developed under the guidance of API 650, appendix G and AWWA D-108. Key benefits: Key design features: The HMT Geodesic Dome’s advanced tBatten bar and gasket assembly completely technology provides excellent benefits. Here’s encapsulate panel edges for unparallelled how: sealing Most effective leak-protection solution— tOverlapping panels ensure additional Engineered for maximum weather-tightness for protection against weather both new tanks and retrofits tHub designed with three levels of sealing to Low maintenance — Aluminum alloys are ensure maximum leak protection corrosion resistant and don’t require painting like steel fixed roofs tHub can be easily removed for inspection or Emissions reduction — reduces wind-induced adjustment of IFR support chains vapor loss, aids in odor control and provides tOptions for fixed or sliding rim connections significant emission credits; for light products such as gasoline, a dome installed over an EFR tCan easily handle the weight of suspended can cut emissions by over 90% aluminum internal floating roofs In-service installation — Can be erected on tIndustry-leading 3D design software for the ground beside the tank or on an EFR and maximum accuracy and shorter design time lifted into place Custom engineered— To accommodate a wide range of spans and loading conditions Protecting your world, one tank at a time™ www.hmttank.com THE HMT GEODESIC DOME DESIGN HMT’s design incorporates features which dramatically Triple seal hub design improve upon existing technology.
    [Show full text]
  • Basic Technical Rules the Nubian Vault (Nv)
    PRODUCTION CENTRE INTERNATIONAL PROGRAMME BASIC TECHNICAL RULES v3 BASIC TECHNICAL RULES THE NUBIAN VAULT (NV) TECHNICAL CONCEPT THE NUBIAN VAULT ASSOCIATION (AVN) ADVICE TO MSA CLIENTS Version 3.0 SEASON 2013-2014 COUNTRY INTERNATIONAL Association « la Voûte Nubienne » - 7 rue Jean Jaurès – 34190 Ganges - France February 2015 www.lavoutenubienne.org / [email protected] / +33 (0)4 67 81 21 05 1/14 PRODUCTION CENTRE INTERNATIONAL PROGRAMME BASIC TECHNICAL RULES v3 CONTENTS CONTENTS.............................................................................................................2 1.AN ANCIENT TECHNIQUE, SIMPLIFIED, STANDARDISED & ADAPTED.........................3 2.MAIN FEATURES OF THE NV TECHNIQUE........................................................................4 3.THE MAIN STAGES OF NV CONSTRUCTION.....................................................................5 3.1.EXTRACTION, FABRICATION & TRANSPORT OF MATERIAL....................................5 3.2.CHOOSING THE SITE....................................................................................................5 3.3.MAIN STRUCTURAL WORKS........................................................................................6 3.3.1.Foundations........................................................................................................................................ 6 3.3.2.Load-bearing walls.............................................................................................................................. 7 3.3.3.Arches in load-bearing
    [Show full text]
  • Insulating Thatched Roofs This Guidance Note Has Been Prepared and Edited by David Pickles
    Energy Efficiency and Historic Buildings Insulating Thatched Roofs This guidance note has been prepared and edited by David Pickles. It forms one of a series of thirteen guidance notes covering the thermal upgrading of building elements such as roofs, walls and floors. First published by English Heritage March 2012. This edition (v1.1) published by Historic England April 2016. All images © Historic England unless otherwise stated. Illustrations drawn by Simon Revill. Our full range of guidance on energy efficiency can be found at: HistoricEngland.org.uk/energyefficiency Front cover: Thatch repairs in progress. © Philip White. Summary This guidance provides advice on the principles, risks, materials and methods for insulating thatched roofs. There are estimated to be about fifty thousand thatched buildings in England today, some of which retain thatch which is over six hundred years old. Thatching reflects strong vernacular traditions all over the country. Well-maintained thatch is a highly effective weatherproof coating as traditional deep thatched eaves will shed rainwater without the need for any down pipes or gutters. Locally grown thatch is a sustainable material, which has little impact on the environment throughout its life-cycle. It requires no chemicals to grow, can be harvested by hand or using traditional farm machinery, requires no mechanical processing and therefore has low embodied energy and can be fixed using hand tools. At the end of its life it can be composted and returned to the land. Thatch has a much greater insulating value than any other traditional roof covering. With the right choice of material and detailing, a well-maintained thatched roof will keep a building warm in winter and cool in summer and has the added advantage of being highly sound-proof.
    [Show full text]
  • Replacing the Roof on Your Manufactured Or Mobile Home Protectmymanufacturedhome
    What You Should Know: Replacing the roof on your manufactured or mobile home ProtectMyManufacturedHome An alteration permit from the Washington State Department of Labor & Industries is required when you reroof a manufactured home. In some cases, plans for the work must also be submitted to L&I for approval prior to doing the work. L&I has a four-step process for home alterations. Here’s how: Step 1: See if you need to submit plans. You need to submit plans if: You are not removing the old shingles or roof covering before installing the new roofing. The new roof covering is heavier than the original. There are repairs to any roof framing, such as trusses or rafters. A second layer of sheathing or additional framing is added to the roof. Plans must be stamped by a Washington professional engineer (PE) or architect. When you reroof, you need to submit plans when buying a permit (see step 2). There is a fee for reviewing plans which is added to the permit. Get more information It usually takes two to three weeks to process plans and plans must be approved before proceeding with the work. Visit www.Lni.wa.gov/FAS You do not need to submit plans if: For structural issues, contact plan review at: 360-902-5218 You are removing the existing roofing and installing For general permit help, call customer new roofing of the same or lesser weight. service at: 360-902-5206 Existing roof sheathing may be removed and new roof Or email [email protected] sheathing used.
    [Show full text]
  • Installers' Handbook Preface
    HANDBOEK VOOR INSTALLATEURS Handboek voor de installatie van VELUX dakvensters Installers' handbook Preface The purpose of this handbook is to provide an overview of the installation of VELUX products. The handbook describes the various aspects of roof construction in association with VELUX roof windows and also provides advice and information on how to obtain the optimal installation. (Third edition, 2010) The VELUX system Chapter 1 2 3 4 5 6 7 8 Other products Chapter 9 Contents Planning Considerations before choosing roof window 5-13 1 Installation of a roof window Installation step by step 15-25 2 Integration – more windows Combination of more than one window 27-45 3 Special installation conditions Installation in various roof constructions 47-63 4 Special roofing materials Installation in various roof materials 65-81 5 Replacement / renovation Replacement of a roof window 83-93 6 Building physics Roof constructions (humidity, heat, sound etc) 95-109 7 Product information Short presentation of VELUX products 111-137 8 Other products Sun tunnel / Flat roof window / Solar hot water system 139-145 9 Contact VELUX Addresses / Advising / Service 146-147 List of telephone numbers 148 Size chart 151 Planning 1 The construction of the house 6-7 User requirements 8 Building regulations 9-13 VELUX 5 Planning 1 The construction of the house To be able to choose the right VELUX roof window for a given situ- ation, it is always recommended to start from the construction of the house, user requirements and current building regulations. Normally, a standard VELUX roof window can satisfy the basic requirements, but often choosing another window type or vari- ant and/or choosing accessories can optimise the function and increase the utility value of the window.
    [Show full text]
  • Top-Operated Centre-Pivot Polyurethane Roof Window GLU 0061
    Edition 2.0 – 05.04.2017 Product information Top-operated centre-pivot polyurethane roof window GLU 0061 Product description High quality moulded polyurethane with white lacquer finish Triple insulating glass unit with Uw 1.1 Top control bar for easy operation even with furniture under the window Integrated ventilation in top control bar and cleanable dust and insect filter Maintenance-free interior surface Maintenance-free exterior covers Roof pitch Can be installed in roof pitches between 15° and 90° Materials Polyurethane around a core of thermally modified timber Glass; float glass / strengthened glass / toughened glass Lacquered aluminium VELUX ThermoTechnology™ insulation Downloads For installation instructions, CAD drawings, 3D BIM objects, 3D GDL objects etc, please visit velux.bg. Certifications The VELUX product EUTR In compliance with the EU Timber factories guarantee Regulation (EUTR), EU regulation quality systems 995/2010 implementation process and environmental REACH We are aware of the REACH regulation management systems and acknowledge the obligations. No through appropriate products are obliged to be registered in accreditations ISO accordance to REACH and none of our 9001 and ISO 14001 products contain any Substances of Very High Concern. Available sizes and daylight area Lining measurements 472 550 660 mm 780 mm 942 mm 1140 mm 1340 mm Size Width (mm) mm mm GLU p CK-- 495 CK02 mm FK-- 605 78 7 (0.22) MK-- 725 GLU MK04 PK-- 887 m m SK-- 1085 78 9 (0.47) Size Height (mm) GLU GLU FK06 MK06 --02 719 m m --04 919 78 11 --06 1119 (0.47) (0.59) GLU GLU GLU GLU --08 1339 FK08 MK08 PK08 SK08 --10 1549 m 398 m 398 1 (0.58) (0.72) (0.92) (1.16) GLU MK10 1600mm (0.85) ( ) = Effective daylight area, m2 Top-operated centre-pivot roof windows make it possible to place furniture directly below the window without obstructing operation of the window.
    [Show full text]
  • Best Practices Single-Family Residences
    SITE PLANNING best practices single-family residences for aesthetic review by the city of coral gables board of architects 2018 1 SINGLE-FAMILY RESIDENCE BEST PRACTICES July 2018 table of contents 1. Purpose & Uses 2. Site Planning 3. Architecture 4. Checklist Purpose & Uses The purpose of the City of Coral Gables, Florida Zoning Code is to implement the Comprehensive Plan (CP) of the City pursuant to Chapter 163, Florida Statutes for the protection and promotion of the safety, health, comfort, morals, convenience, peace, prosperity, appearance and general welfare of the City and its inhabitants. ~ Zoning Code Section 1-103 Purpose of the City of Coral Gables Zoning Code PURPOSE & USE Single-Family Residential (SFR) District The Single-Family Residential (SFR) District is intended to accommodate low density, single-family dwelling units with adequate yards and open space that characterize the residential neighborhoods of the city. The city is unique not only in South Florida but in the country for its historic and archi- tectural treasures, its leafy canopy, and its well-defined and livable neighborhoods. These residential areas, with tree-lined streets and architecture of harmonious proportion and human scale, provide an oasis of charm and tranquility in the midst of an increasingly built-up metropolitan environment. The intent of the Single-Family Residential code is to protect the distinctive character of the city, while encouraging excellent architectural design that is responsible and responsive to the individual context of the city’s diverse neighborhoods. The single-family regulations, as well as the design and performance standards in the Zoning Code, seek to ensure that the renovation of residences as well as the building of residences is in accord with the civic pride and sense of stewardship felt by the citizens of Coral Gables.
    [Show full text]
  • Katalog Produktow GB 2008.Indb
    ROOF WINDOWS INTRODUCTION Consultation with the architect helps make decision 8 www.fakro.com Loft Conversion-planning Building or renovation of a house is an investment which requires not only financial expenditure, but also considered decisions and solutions. Each matter should be discussed with professionals who will ad- vise the best way of solving problems. When deciding how and where to place roof windows you should consult an architect, who will help you to choose the right window type depending on the proposed use of the loft. He will also give you advice concerning the window’s glass surface area decided by the ratio to the total floor area and also where to place the win- dows to gain the maximum benefit. Nowadays roof windows are often an indispensable element of newly built structures. They create new, unique, individual possibilities. When adapting or con- The attic before conversion verting the loft and also installing roof windows your loft can be easily changed into a functional, stylish and elegant space. Depending on the client’s individ- ual requirements and the ingenuity of the architects, even the most exceptional ideas can be prepared in the form of computerised 3D visualisation of the project which helps your dreams come true. A completed conversion with two roof windows A completed conversion with four roof windows and blinds ROOF WINDOW 9 ROOF WINDOWS VERSUS DORMER When planning to develop the loft there are two options to get light in: building a dormer (until recently a very popular solution) or installing (becoming more and more popular ) modern roof windows.
    [Show full text]
  • Tilcor-Installation-Manual-16-EN.Pdf
    INSTALLATION MANUAL BOND / CLASSIC / TUDOR / SHAKE / ROYAL / ANTICA These installation details are provided to demonstrate the recommended installation methods for Tilcor products and accessories. The details and information in this document reflect current roofing practices used in New Zealand. Consult with Tilcor Roofing Systems for additional information. Ross Roof Group Ltd +64 9 299 9498 faks +64 9 298 4114 1c Inlet Road, Takanini 2112, PO Box 72062, Papakura 2244, e-mail: [email protected] web: www.tilcor.com New Zealand 1. General Information ................................................................................. 3 2. Recommended Tools ............................................................................... 9 3. Profile and Flashing Specifications .......................................................... 10 4. Preparation of The Roof Surface for Installation ................................... 14 5. Tile (BOND, CLASSIC, TUDOR, ANTICA) Installation ............................... 16 6. Tile Installation (SHAKE, ROYAL) .............................................................. 19 7. Eaves Flashing ........................................................................................... 20 8. Box Barge Installation (Bond, Classic, Tudor, Shake, Royal) ................. 21 9. Installation of Barrels at The Ridge and Hip ............................................ 22 10. Roof Window Installation ........................................................................ 23 11. Roof Ventilation, Extractor and Sanitary
    [Show full text]
  • Technical Summary
    TM NEW CONSTRUCTION HURRICANE TECHNICAL SUMMARY 2019 FORTIFIED HOME™ Technical Requirements INTRODUCTION New Home This FORTIFIED Home™ standard helps homeowners in coastal areas strengthen their houses against hurricanes. Incorporating FORTIFIED features when repairing, rebuilding, or renovating your home will transform your house into a more resilient and durable property. The FORTIFIED features focus first on strengthening and protecting the roof because it is the home’s first line of defense against severe weather events. This includes things like sealing the roof deck to prevent wind-driven rain from getting inside and using a roof covering that is rated for the wind speeds in your area to reduce the chances it will lift up or blow off during high winds. Protecting the openings in the house, things like entry doors, windows, and especially garage doors, is also important. Creating a continuous load path by tying the roof to the walls, the wall above to the wall below, and the first floor walls to the foundation will significantly strengthen your home when Mother Nature strikes. There are three levels of FORTIFIED Home: 1. FORTIFIED Roof™ — focus is on the roof 2. FORTIFIED Silver™ — focus is on roof overhangs, opening protection, gable ends, and attached structures 3. FORTIFIED Gold™ — focus is on tying all components of the structure together For more detailed information about how to make your home stronger, safer, and more hurricane-resistant, please visit www.DisasterSafety.org/FORTIFIED. You can also follow us on Twitter at @DisasterSafety and on Facebook at www.facebook.com/buildfortified. Page 1 of 7 FORTIFIED HOME™ Hazard: Hurricane Technical Requirements Applicable where the design wind speed for Vult in accordance New Home with ASCE 7-10 (or 7-16) exceeds 115 mph, or Vasd in accordance with ASCE 7-05 exceeds 90 mph.
    [Show full text]
  • Influence of Roof Windows Area Changes on the Classroom
    sustainability Article Influence of Roof Windows Area Changes on the Classroom Indoor Climate in the Attic Space: A Case Study Erika Dolnikova * , Dusan Katunsky , Marian Vertal and Marek Zozulak Institute of Architectural Engineering, Faculty of Civil Engineering, Technical University of Kosice, 042 00 Kosice, Slovakia; [email protected] (D.K.); [email protected] (M.V.); [email protected] (M.Z.) * Correspondence: [email protected]; Tel.: +421-055-602-4162 Received: 28 April 2020; Accepted: 17 June 2020; Published: 20 June 2020 Abstract: Windows are a complex part of building design and provide a considerable benefit, including to school buildings. For the evaluation of the daylighting conditions prevailing in classrooms, the daylight factor (DF) was considered as the most appropriate parameter for indicating the quantity of admitted daylight. The DF values and CIE overcast sky were calculated using Velux Daylight Visualizer 3 software. The task of the paper is to compare various roof window openings in relation to the level of daylight in the attic, looking to optimize the use of the attic for teaching. The indoor air temperature has a general influence on comfort in the interior, in addition to daylight. In winter, the situation is not critical. The thermal insulation properties of packaging structures are sufficient. The situation is worse in summer, due to the fact that the heat-storage properties are undersized and there is excessive overheating of the indoor air. Four variants of roof windows and their influence on the overall microclimate in the attic are compared. The variant without roof windows is a suitable solution with regard to minimum overheating, but the worst situation for daylight.
    [Show full text]