Hawaii Commercial Building Guidelines for Energy Efficiency
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Airflow Simulations Around OA Intake Louver with Electronic Velocity
Airflow Simulations around OA Intake Louver with Electronic Velocity Sensors Hwataik Han*1, Douglas P. Sullivan2 and William J. Fisk3 1 Professor, Kookmin University, Korea 2 Research Associate, Indoor Environment Department, Lawrence Berkeley National Laboratory, USA 3 Director, Indoor Environment Department, Lawrence Berkeley National Laboratory, USA Abstract It is important to control outdoor airflow rates into HVAC systems in terms of energy conservation and healthy indoor environment. Technologies are being developed to measure outdoor air (OA) flow rates through OA intake louvers on a real time basis. The purpose of this paper is to investigate the airflow characteristics through an OA intake louver numerically in order to provide suggestions for sensor installations. Airflow patterns are simulated with and without electronic air velocity sensors within cylindrical probes installed between louver blades or at the downstream face of the louver. Numerical results show quite good agreements with experimental data, and provide insights regarding measurement system design. The simulations indicate that velocity profiles are more spatially uniform at the louver outlet relative to between louver blades, that pressure drops imposed by the sensor bars are smaller with sensor bars at the louver outlet, and that placement of the sensor bars between louver blades substantially increases air velocities inside the louver. These findings suggest there is an advantage to placing the sensor bars at the louver outlet face. Keywords: ventilation; outdoor -
How to Perform Mold Inspections
~ 1 ~ HOW TO PERFORM MOLD INSPECTIONS Mold inspection is a specialized type of inspection that goes beyond the scope of a general home inspection. The purpose of this publication is to provide accurate and useful information for performing mold inspections of residential buildings. This book covers the science, properties and causes of mold, as well as the potential hazards it presents to structures and to occupants’ health. Inspectors will learn how to inspect and test for mold both before and after remediation. This text is designed to augment the student’s knowledge in preparation for InterNACHI’s online Mold Inspection Course and Exam (www.nachi.org). This manual also provides a practical reference guide for use on-site at inspections. Authors: Benjamin Gromicko, Director of InterNACHI Online Education, and Executive Producer, NACHI.TV Nick Gromicko, Founder, International Association of Certified Home Inspectors, and Founder, International Association of Certified Indoor Air Consultants Edited by: Kate Tarasenko / Crimea River To order online, visit: www.nachi.org www.IAC2.org www.InspectorOutlet.com Copyright © 2009-2010 International Association of Certified Indoor Air Consultants, Inc. (IAC2) www.IAC2.org All rights reserved. ~ 2 ~ Mold Inspection: Table of Contents Overview…....................................................................................... 3 Section 1: Types of Mold Inspections.............................................. 5 Section 2: IAC2 Mold Inspection Standards…………………………… 9 Section 3: What is Mold? ………………………………………………… -
Code-Compliant Solution for Combustible Plenums
Expect More More time savings, lower installation costs More cost savings, more billable square footage More building space, More solutions for code more design flexibility compliant protection of both air and grease ducts FyreWrap®Duct Insulation delivers more to every member of your project team. FyreWrap® Elite™1.5 Duct Insulation is ideal ■ Complies with NFPA 96, ICC and for the insulation of duct systems in hotels, IAPMO Codes. schools, restaurants, high rise condos, ■ Made in USA. medical facilities, research labs, and sports A FyreWrap product specification in arenas and stadiums. This flexible, light- several formats is available at weight duct wrap www.arcat.com; search using keywords provides a single Unifrax, FyreWrap fire protection or www.unifrax.com. solution for both For more information air distribution and grease duct systems. on FyreWrap Elite 1.5 FyreWrap Elite 1.5 Duct Insulation offers: or other products, ■ Space-saving shaft alternative for air certifications, code distribution and grease duct systems. compliance, installa- ■ 2 hour fire-rated duct protection; zero tion instructions or drawings, contact clearance to combustibles. Unifrax Corporate headquarters USA ■ Solutions for building design and complex at 716-278-3800. job configurations. ■ Thin, lightweight flexible blanket for faster, easier installation. www.unifrax.com ■ Offers both fire and insulation performance. PLENUM FIRE PROTECTION Steiner tunnel windows and cover Code-compliant Solution for Combustible Plenums Fire protection wrap systems can provide -
Performance Measurements of a Unique Louver
Performance Measurements Grant O. Musgrove Southwest Research Institute, of a Unique Louver Particle San Antonio, TX 78238 e-mail: [email protected] Separator for Gas Turbine Engines Karen A. Thole Mechanical and Nuclear Engineering Department, Solid particles, such as sand, ingested into gas turbine engines, reduce the coolant flow The Pennsylvania State University, in the turbine by blocking cooling channels in the secondary flow path. One method to University Park, PA 16802 remove solid particles from the secondary flow path is to use an inertial particle separa- tor because of its ability to incur minimal pressure losses in high flow rate applications. In this paper, an inertial separator is presented that is made up of an array of louvers Eric Grover followed by a static collector. The performance of two inertial separator configurations was measured in a unique test facility. Performance measurements included pressure Joseph Barker loss and collection efficiency for a range of Reynolds numbers and sand sizes. To comple- ment the measurements, both two-dimensional and three-dimensional computational United Technologies Corporation – results are presented for comparison. Computational predictions of pressure loss agreed Pratt & Whitney, with measurements at high Reynolds numbers, whereas predictions of sand collection East Hartford, CT 06108 efficiency for a sand size range 0–200lm agreed within 10% of experimental measure- ments over the range of Reynolds numbers. Collection efficiency values were measured to be as high as 35%, and pressure loss measurements were equivalent to less than 1% pres- sure loss in an engine application. [DOI: 10.1115/1.4007568] Introduction operating principle of inertial separators is to cause the particle- laden flow to abruptly change trajectory, whereby the particles do Aircraft gas turbines ingest solid particles during takeoff, land- not react to the change in flow direction due to their larger inertia ing, and while flying in dusty environments. -
High Performance House Best Practices Guide
New York State Energy Research & Development Authority High Performance House Best Practices Guide Design Intelligence for Energy Performance in Single Family Homes TABLE OF CON T EN T S High Performance House 1.1 Initial Work................................... 3 1.2 Process.......................................... 4 1.3 Testing........................................... 4 1.3.1 Building Construction.............................. 4 1.3.2 Building Form and Siting......................... 5 1.3.3 Passive Sustainable Strategies................ 6 1.3.4 Active Sustainable Strategies................... 14 1.4 Conclusions................................... 14 1.4.1 Additional Recommendations.................. 15 2 1.1 INitiAL WORK 1.1 Initial Work ON cti Preliminary analysis looked purely at geometric implications on energy use. This theoretical investigation tested a variety of building forms and found two general guidelines that govern performance. Across all building manipulations, results showed that forms minimizing volume and RODU T maximizing southern exposure perform best. This lines with rational thought; increased volume N increases the volume of required conditioned space, while maximizing southern exposure allows I for greatest winter solar gains and daylighting. Following this study, energy analysis was given for three, previously conceived housing designs – “Slope House”, “Underground House” and “X House”. In all cases, formal design (siting, building form, orientation) were given, fixed parameters. This proved a challenge to the energy optimization of the house. For the “Slope House”, building volume opens to the west without the benefit of southern expo- sure on the open face. Passive solar gains were minimal, with excessive shading on south facing windows. The majority of glazing is to the north, which effectively cuts the building’s thermal resistance/storage without the offsetting solar gains received on southern exposures. -
System Controls Engineering Guide
SECTION G Engineering Guide System Controls System Controls Engineering Guide Introduction to VAV Terminal Units The control of air temperature in a space requires that the loads in the space are offset by some means. Space loads can consist of exterior loads and/or interior loads. Interior loads can consist of people, mechanical equipment, lighting, com puters, etc. In an 'air' conditioning system compensating for the loads is achieved by introducing air into the space at a given temperature and quantity. Since space loads are always fluctuating the compensation to offset the loads must also be changing in a corresponding manner. Varying the air temperature or varying the air volume or a combination of both in a controlled manner will offset the space load as required. The variable air volume terminal unit or VAV box allows us to vary the air volume into a room and in certain cases also lets us vary the air temperature into a room. YSTEM CONTROLS YSTEM S The VAV terminal unit may be pressure dependent or pressure independent. This is a function of the control package. ENGINEERING GUIDE - Pressure Dependent A device is said to be pressure dependent when the flow rate passing through it varies as the system inlet pressure fluctuates. The flow rate is dependent only on the inlet pressure and the damper position of the terminal unit. The pressure dependent terminal unit consists of a damper and a damper actuator controlled directly by a room thermostat. The damper is modulated in response to room temperature only. Since the air volume varies with inlet pressure, the room may experience temperature swings until the thermostat repositions the damper. -
Analysis of Cooling Load Calculations for Underfloor Air Distribution Systems
The 13th Asia Pacific Conference on the Built Environment: Next Gen Technology to Make Green Building Sustainable , 19-20 Nov 2015 (Thu-Fri), Hong Kong. Analysis of cooling load calculations for underfloor air distribution systems Dr. Sam C. M. Hui * and Miss ZHOU Yichun Department of Mechanical Engineering, The University of Hong Kong Pokfulam Road, Hong Kong * E-mail: [email protected] Abstract Underfloor air distribution (UFAD) systems use an underfloor supply plenum located between the structural floor slab and a raised floor system to supply conditioned air through floor diffusers or terminal units directly into the building’s occupied zone. If designed properly, they have the potential to enhance energy efficiency, indoor air quality and building life cycle performance. However, the application of UFAD system is still obstructed by the information gap in some fundamental issues, such as cooling load calculation. All the cooling load calculation methods for UFAD systems nowadays have limitations and drawbacks and most building designers are not familiar with them. This research aims to investigate the cooling loads calculation methods for UFAD systems. Fundamental principles of UFAD with different configurations are studied to analyse the effects on cooling load components. Critical evaluation is made on the key factors and issues affecting the cooling load and how they differ from the overhead air distribution systems. It is found that thermal stratification, management of solar and lighting loads, architectural design and thermal properties of structural floor slab will influence the cooling load and must be evaluated carefully. It is hoped that the findings could improve the understanding of UFAD systems and provide practical information for performing the cooling load calculations and optimising the system performance. -
Damper Application Guide 1.” 1 Common 2 2 + Hot
Control of Dampers ®® INDEX I. INTRODUCTION A. Economizer Systems ............................................................................................................ 3 B. Indoor Air Quality ...................................................................................................................3 C. Damper Selection ..................................................................................................................3 II. DAMPER SELECTION A. Opposed and Parallel Blade Dampers ..................................................................................3 B. Flow Characteristics...............................................................................................................4 C. Damper Authority ..................................................................................................................4 D. Combined Flow ......................................................................................................................6 III. ADDITIONAL CONSIDERATIONS A. Economizer Systems .............................................................................................................6 B. Building Pressure ...................................................................................................................8 C. Mixed Air Temperature Control ..............................................................................................8 D. Actuators - General ................................................................................................................8 -
Underfloor Air Distribution
University of Delaware Karen Schulte Center for the Arts Mechanical Option Underfloor Air Distribution: An underfloor air distribution system utilizes a plenum space between the structural slab and the underside of a raised floor to distribute the conditioned air to the room. An underfloor air distribution system creates a stratified condition where the natural buoyancy of air removes heat and contaminates from the occupied zone. Diffusers located in the elevated floor slab distribute air to the room from the plenum. Since the diffusers are located in the floor, the supply air temperatures must be warmer then the conventional overhead air distribution systems because of the immediate proximity of the supply air to the occupied zone. For cooling the supply air temperature should range from 63°F- 68°F, this temperature range will prevent overcooling the occupants of the space. The potential benefits that occur as a result of the implementation of underfloor air distribution include increased thermal comfort, better indoor air quality, reduced outdoor airflow, reduced floor to floor heights, and reduced supply fan horsepower. The increase in thermal comfort arises from the fact that the supply air temperature is higher then conventional overhead distribution systems and the floor diffusers induce local circulation and mixing in the occupied zone to a relatively uniform temperature. The improvements in indoor air quality result from natural flow of air in the underfloor system as compared to the overhead air distribution system. In the overhead system the contaminants in the air that collect at the ceiling level, due to the natural buoyancy of air, are forced back into the breathing zone by the induced mixing of ceiling diffusers to create a uniform environment. -
IAQ Economizer LOGIC BOX
IAQ Economizer LOGIC BOX Split-system Economizing/Indoor Air Quality/CO Alarm Activated Works on forced air systems, with or without air conditioning installed Enables cost saving cooling strategy: Expensive mechanical cooling can be set at a higher temperature Fresh Air Cooling can be set at a lower temperature Supports a variety Indoor Air Quality configurations: Continuous introduction Timed introduction CO2 or VOC sensor activated introduction Provides alarm activated fresh air introduction supporting CO or other alarm installations Occupant interface provides easy override, along with readiness, damper and fault status, (continuous fault detection) Operational tests can be conducted from within the conditioned space Quick connect wiring harnesses provide fast, correct termination FRESH AIR MANUFACTURING CO. FAMCO IAQ Economizer Famcoiaq.com 649 N. Ralstin St., Meridian, ID 83642 * (208)884-8931 * (800)-234-1903 * FAX: (208)884-8943 IAQ Economizer ECONOMIZER SYSTEM Damper Actuator Exhaust Damper Transformer Thermostat Logic Literature Box Cables Damper Box Actuator – Honeywell MS8105A1030, 24 VAC, 44 lb-in torque Outdoor thermostat- Dayton RLZ94A Nema 4X, Range 30º-110º F Transformer – RIB Functional Devices, Inc. TR50VA005 , 50VA All required System Cables are provided: • Power 40’ • Furnace 40’, plenum rated, HVAC industry standard color coding for furnace board termination • Damper Box 50’, plenum rated • Outdoor thermostat, 70’ , shielded, non polarity sensitive FRESH AIR MANUFACTURING CO. FAMCO IAQ Economizer -
Building Applications, Opportunities and Challenges of Active Shading Systems: a State-Of-The-Art Review
energies Review Building Applications, Opportunities and Challenges of Active Shading Systems: A State-Of-The-Art Review Joud Al Dakheel and Kheira Tabet Aoul * ID Architectural Engineering Department, United Arab Emirates University, P.O. Box 15551 Al Ain, UAE; [email protected] * Correspondence: [email protected]; Tel.: +971-566-433-648 Academic Editor: Arman Hashemi Received: 28 June 2017; Accepted: 4 August 2017; Published: 23 October 2017 Abstract: Active shading systems in buildings have emerged as a high performing shading solution that selectively and optimally controls daylight and heat gains. Active shading systems are increasingly used in buildings, due to their ability to mainly improve the building environment, reduce energy consumption and in some cases generate energy. They may be categorized into three classes: smart glazing, kinetic shading and integrated renewable energy shading. This paper reviews the current status of the different types in terms of design principle and working mechanism of the systems, performance, control strategies and building applications. Challenges, limitations and future opportunities of the systems are then discussed. The review highlights that despite its high initial cost, the electrochromic (EC) glazing is the most applied smart glazing due to the extensive use of glass in buildings under all climatic conditions. In terms of external shadings, the rotating shading type is the predominantly used one in buildings due to its low initial cost. Algae façades and folding shading systems are still emerging types, with high initial and maintenance costs and requiring specialist installers. The algae façade systems and PV integrated shading systems are a promising solution due to their dual benefits of providing shading and generating electricity. -
A Laboratory Method for Measuring the Heat Distribution Of
A LABORATORY METHOD FOR MEASURING THE HEAT DISTRIBUTION OF LUMINAIRES AND ITS APPLICATION FOR BUILDING HEATING AND COOLING ENERGY SAVING BY Hankun Li Submitted to the graduate degree program in Architectural Engineering and the Graduate Faculty of the University of Kansas in partial fulfillment of the requirements for the degree of Master of Science. ________________________________ Chairperson Dr. Hongyi Cai ________________________________ Dr. Brian A. Rock ________________________________ Dr. Xianglin Li Date Defended: The Thesis Committee for Hankun Li certifies that this is the approved version of the following thesis: A LABORATORY METHOD FOR MEASURING THE HEAT DISTRIBUTION OF LUMINAIRES AND ITS APPLICATION FOR BUILDING HEATING AND COOLING ENERGY SAVING ________________________________ Chairperson Dr. Hongyi Cai Date approved: << ii ABSTRACT This study was aimed to explore the energy saving potential of a new system architecture of solid-state lighting fixtures that was designed to help utilize the heat generated by LEDs for spacing heating in heating season and re-heating in cooling season. The new system architecture, which deploys an innovation of integrative light and heat arrangement in low profile, helps harvest the LED heat and direct most of the heat to the room space while minimizing heat leakage to the ceiling cavity. A well-designed laboratory experiment was carried out in a newly developed Calorimeter chamber that was used to find out heat distribution of luminaires in the conditioned room cavity and ceiling plenum, followed by an estimation of potential energy savings via computer simulation in Energy Plus. A typical primary elementary school classroom was used in this computer simulation equipped with LED fixtures with different heat distribution patterns.