PRIDE IN CRAFTSMANSHIP

UNPARALLELED INGENUITY

ENVIRONMENTAL PROTECTION

CLOACINA.COM | [email protected] | 888.483.8469 PACKAGE WASTEWATER TREATMENT ABOUT CLOACINA

1. Roman Goddess of the Sewers 2. Purveyor of package wastewater treatment plants and equipment

Origin: Ancient ; cloaca [sewer]

OVERVIEW Cloacina, LLC is a manufacturer and purveyor of package wastewater treatment plants and equipment located on the Central Coast of California. It is owned and managed by a family of licensed operators and maintenance mechanics, now four generations deep, with more than a century of combined wastewater treatment experience. Pride in craftsmanship. Unparalleled ingenuity. Environmental protection. At the heart of Cloacina, these are the values driving the design and production of each package wastewater treatment plant.

HISTORY Legend has it that soon after the completion of the (The main sewer line constructed in the late 500’s BC in Rome), a statue of a woman was found in the sewers. Promptly rescued and cleaned, she became Cloacina, the Roman Goddess of the Sewers. Romans came to believe that Cloacina ruled over and protected their sanitary workers and the extensive sewer system they serviced.

While we may never know why that statue of the woman was thrown into the cloaca, it is clear that the sewer system revolutionized cleanliness standards and daily life for the citizens of Rome and made the once-discarded statue a revered goddess. Her importance is evidenced by the fact that a coin, still available today, was minted in her honor in 46 BC. Additionally, had a Cloacina statue and shrine erected on the in the 8th Century BC. This shrine ROMAN CLOACINA COIN is believed to be located on the entrance to the sewer system — an CIRCA 46 BC ancient manhole. The foundations of this landmark are still evident in Rome.

3 CLOACINA.COM [email protected] 888.483.8469 . REVOLUTIONARY PRODUCTS

Package wastewater treatment plants have a bad reputation. Until the introduction of Cloacina’s product line, they were cookie-cutter, one-size-fits-all designs with low-end components and equipment. They were noisy, difficult to install and operate and had short useful lives.

CLOACINA IS REVOLUTIONIZING PACKAGE WASTEWATER TREATMENT!

I Tanks, equipment skids and panels are fabricated from stainless steel

Ships as a factory-assembled, complete wastewater treatment plant not as II individual pieces of equipment III Each treatment plant is wet tested for a minimum of 24 hours prior to shipping IV The most advanced controls system available

All ancillary equipment must have a proven track record in the wastewater V industry to be included in a Cloacina treatment system

No cookie cutter designs -- every package plant is custom designed to meet VI the client’s project needs

Designed by operators for operators -- all plants are easy to install, operate VII and maintain

All equipment is either semi-sound attenuated or sound-attenuated to VIII address noise concerns

Each piece of major equipment is tagged, has an assigned QR code and can IX be accessed through Scanual™ -- Cloacina’s digital O&M manual

Provides the greatest value of any package wastewater treatment plant X currently on the market XI Modular designs allow for future plant expansion

CLOACINA.COM [email protected] 888.483.8469 4 STAGE 1TM

ALL EQUIPMENT IS ELECTRICAL PANEL AND FACTORY-INSTALLED CONTROLS SYSTEM ARE AND WET TESTED FOR A FACTORY-INSTALLED MINIMUM OF 24 HOURS AND TESTED SEMI-SOUND ATTENUATED BLOWERS

BURIED INSTALLATION MODEL SKID WILL BE AT GRADE

CORROSION RESISTANT 304 STAINLESS STEEL TANKAGE EQUIPMENT SKID IS AND COMPONENTS COME FACTORY-INSTALLED STANDARD ON ALL MODELS AND TESTED

2,000 GPD UNIT SHOWN 10.4’ L X 6.4’ W X 10’ H Prior to delivery, clients will be given exact connection points for power, communication, influent, effluent and WAS.

THIS MODEL CAN RECLAIM 100% OF THE TREATED EFFLUENT

5 CLOACINA.COM [email protected] 888.483.8469 PRODUCT DESCRIPTION

TYPICAL INFLUENT PARAMETERS (0-2,000 GPD) The Stage I is a package wastewater treatment CONSTITUENT CONCENTRATION UNITS NOTES plant designed for small facilities and those with LIMIT limited footprints or future plans for expansion. TSS 0 - 600 mg/L Recognizing that a pump station is necessary for most wastewater treatment systems, Cloacina BOD5 2,000 - 5,000 mg/L 2,000 average/5,000 peak developed a compact unit that provides high- pH 5.0 - 8.0 quality treatment in the footprint of the average pump station. Most Stage I systems are designed Temperature 5• - 20• •C Average to treat a maximum of 2,000 Gallons per Day (GPD). The unit can operate indefinitely as a TYPICAL EFFLUENT PARAMETERS treatment system meeting 90% removal of LIMITATIONS CONCENTRATION UNITS NOTES Biochemical Oxygen Demand (BOD) and 90% Total LIMIT Suspended Solids (TSS). Should a change in flow, loading or discharge permit requirements dictate TSS 90% removal mg/L Average of composite sample additional treatment or equipment, the Stage I can BOD5 90% removal mg/L Average of composite sample be converted into a lift station pumping to the new pH* 6.0 - 9.0 After correction downstream wastewater treatment equipment. Cloacina’s Stage I includes a cutting-edge controls DO >1.0 mg/L system that allows facility staff to view real-time TDS Not addressed in process operating conditions, remotely monitor and make changes to system parameters, collect information *pH typically corrected for acidic conditions only for reporting purposes and verify the completion of routine maintenance. Stage I systems can be TYPICAL APPLICATIONS stand-alone units or designed to fit into an existing buried vessel. Sanitary sewer or on-site disposal pre-treatment

CLOACINA.COM [email protected] 888.483.8469 6 INDUSTRIAL BATCH REACTORTM (IBR)

SLUDGE STORAGE CHAMBER SCREENING (STATIC SCREEN SHOWN)

ALL EQUIPMENT IS FACTORY-INSTALLED AND WET TESTED FOR A MINIMUM OF 24 HOURS

ALUMINUM STAIRS

CORROSION RESISTANT 304 STAINLESS STEEL TANKAGE AND COMPONENTS ARE STANDARD ON ALL MODELS pH ADJUSTMENT EQUIPMENT IS STANDARD ON ALL MODELS SEMI-SOUND ATTENUATED BLOWERS ELECTRICAL PANEL AND CONTROLS SYSTEM ARE 5,000 GPD UNIT SHOWN FACTORY-INSTALLED AND TESTED 23’ L X 8’ W X 10’ H Prior to delivery, clients will be given exact connection points for power, communication, influent, effluent and WAS.

THIS MODEL CAN RECLAIM 100% OF THE TREATED EFFLUENT

7 CLOACINA.COM [email protected] 888.483.8469 PRODUCT DESCRIPTION

TYPICAL INFLUENT PARAMETERS (1,000 - 10,000 GPD) The Industrial Batch Reactor (IBR) is a package wastewater treatment plant that treats industrial CONSTITUENT CONCENTRATION UNITS NOTES LIMIT wastewater utilizing Activated Sludge and gravity clarification in a single vessel. The tank and TSS 0 - 600 mg/L equipment skid are fabricated from stainless steel BOD5 2,000 - 8,000 mg/L 2000 average/8000 peak and all interior and exterior components are pH 5.0 - 8.0 manufactured from high-quality, corrosion- resistant materials. Cloacina’s IBR is ideal for Temperature 5• - 20• •C Average clients needing a wastewater system with a small footprint that can pre-treat wastewater prior to TYPICAL EFFLUENT PARAMETERS sewer disposal, sub-surface reuse, frost and/or dust control water. The system includes a LIMITATIONS CONCENTRATION UNITS NOTES LIMIT cutting-edge controls system which allows facility staff to remotely access, monitor and make TSS 95% removal mg/L Average of composite sample changes to the plant, collect data for reporting and BOD5 95% removal mg/L Average of composite sample verify the completion of routine maintenance. The IBR is factory-tested and completely assembled pH* 6.0 - 9.0 After correction prior to shipment. It is easy to install, operate and DO >2.0 mg/L maintain. Models are available for buried, partially-buried and above-grade installations. The TDS Not addressed in process Industrial Batch Reactor (IBR) is perfect for *pH typically corrected for acidic conditions only installations in compact and remote locations. TYPICAL APPLICATIONS High-strength, industrial process waste: Wineries, breweries and food production

CLOACINA.COM [email protected] 888.483.8469 8 MEMPACTM-I

ALL SENSORY EQUIPMENT IS ALUMINUM STAIRS MOUNTED ON THE CLOACINA SLIDE RAIL SYSTEM AND IS ACCESSIBLE FROM THE INSPECTION PLATFORM

TRAINS CAN BE ARRANGED IN ANY CONFIGURATION

ALL EQUIPMENT IS FACTORY-INSTALLED AND WET TESTED FOR A MINIMUM OF 24 HOURS

TRAIN 1

TRAIN 2

MEMBRANE FILTRATION EQUIPMENT IS FACTORY-INSTALLED AND WET TESTED FOR A MINIMUM OF 24 HOURS

ELECTRICAL PANEL AND CONTROLS SYSTEM ARE CORROSION RESISTANT 304 FACTORY-INSTALLED AND TESTED STAINLESS STEEL TANKAGE AND COMPONENTS COME STANDARD ON ALL MODELS

OPTIONAL DE-WATERING PRESS 25,000 GPD UNIT SHOWN 56.4’ L X 10’ W X 10’ H

Prior to delivery, clients will be given exact connection points for power, communication, influent, effluent and WAS.

THIS MODEL CAN RECLAIM 100% OF THE TREATED EFFLUENT

9 CLOACINA.COM [email protected] 888.483.8469 PRODUCT DESCRIPTION

TYPICAL INFLUENT PARAMETERS (1,000 - 500,000 GPD) Cloacina’s MEMPAC-I Membrane Bio Reactor (MBR) CONSTITUENT CONCENTRATION UNITS NOTES is a custom package wastewater treatment system LIMIT designed to treat high-strength industrial waste for TSS 0 - 1,500 mg/L clients with stringent discharge requirements or the desire to reclaim treated effluent for re-use. The BOD5 0 - 15,000 mg/L MEMPAC-I includes screening, primary treatment, pH 5.0 - 8.0 activated sludge and membrane clarification • • • necessary to stabilize fluctuating influent strength Temperature 5 - 20 C Average and loading while improving downstream treatment and performance. Unlike activated sludge plants that TYPICAL EFFLUENT PARAMETERS utilize a traditional clarifier, membrane treatment LIMITATIONS CONCENTRATION UNITS NOTES does not allow solids to carry over into the effluent. LIMIT All interior and exterior components of the MEMPAC-I are manufactured from high-quality, TSS <10 mg/L corrosion-resistant materials and all tankage and BOD5 <10 mg/L equipment skids are fabricated from stainless steel. Prior to shipping, all equipment is factory-installed pH 6.5 - 8.0 After correction and wet tested for a minimum of 24 hours. The TDS Not addressed in process compact design of the MEMPAC-I makes it ideal for industrial projects with small footprints and remote locations. TYPICAL APPLICATIONS High-strength, industrial process waste: Wineries, breweries and food production

CLOACINA.COM [email protected] 888.483.8469 10 MEMPACTM-E

ALL SENSORY EQUIPMENT IS MEMBRANE FILTRATION EQUIPMENT MOUNTED ON THE CLOACINA SLIDE IS FACTORY-INSTALLED RAIL SYSTEM AND IS ACCESSIBLE INTEGRATED SCREENING FROM THE INSPECTION PLATFORM AND WET TESTED FOR A MINIMUM OF 24 HOURS

ALL EQUIPMENT IS FACTORY-INSTALLED AND WET TESTED FOR A MINIMUM OF 24 HOURS

SEMI-SOUND ATTENUATED BLOWERS

CORROSION RESISTANT 304 STAINLESS STEEL TANKAGE AND COMPONENTS COME STANDARD ON ALL MODELS

ALUMINUM STAIRS AND PLATFORM(S) (OPTIONAL FULL CATWALK AND STAIRS SHOWN) ELECTRICAL PANEL AND CONTROLS SYSTEMS ARE FACTORY-INSTALLED 15,000 GPD UNIT SHOWN AND TESTED 19.8’ L X 8’ W X 8’ H Prior to delivery, clients will be given exact connection points for power, communication, influent, effluent and WAS.

THIS MODEL CAN RECLAIM 100% OF THE TREATED EFFLUENT

11 CLOACINA.COM [email protected] 888.483.8469 PRODUCT DESCRIPTION

TYPICAL INFLUENT PARAMETERS (1,000 - 30,000 GPD) The MEMPAC-E Membrane Bio Reactor (MBR) is CONSTITUENT CONCENTRATION UNITS NOTES the perfect package wastewater treatment system LIMIT for municipal clients who need an immediate TSS <300 mg/L treatment solution, those who are budget- BOD5 <400 mg/L conscious but still have to meet stringent discharge requirements or those with the desire to Temperature 5 - 20• •C Average reclaim treated effluent for re-use. Designed for TN 40 mg/L low flow ranges, the MEMPAC-E has standard, streamlined designs and economized equipment selections while still incorporating many ofthe TYPICAL EFFLUENT PARAMETERS same features that clients have become LIMITATIONS CONCENTRATION UNITS NOTES accustomed to on other MEMPAC™ models: all LIMIT interior/exterior components are manufactured BOD5 <10 mg/L from high-quality, corrosion-resistant materials and all tankage and equipment skids are fabricated TSS <10 mg/L from stainless steel. Prior to shipment, all TN <10 mg/L equipment is factory-installed and wet tested for a minimum of 24 hours. The compact design of the MEMPAC-E makes it ideal for projects with small TYPICAL APPLICATIONS footprints and remote locations. Remote domestic waste: Mobile home parks, resorts, schools, campgrounds, commercial developments, truck stops and rest areas

CLOACINA.COM [email protected] 888.483.8469 12 MEMPACTM-M

ALUMINUM STAIRS AND PLATFORM(S) INTEGRATED SCREENING

ALL SENSORY EQUIPMENT IS MOUNTED ON THE CLOACINA SLIDE RAIL SYSTEM AND IS ACCESSIBLE FROM THE INSPECTION PLATFORM

ALL EQUIPMENT IS FACTORY-INSTALLED AND WET TESTED FOR A MINIMUM OF 24 HOURS

SEMI-SOUND CORROSION RESISTANT 304 ATTENUATED BLOWERS STAINLESS STEEL TANKAGE AND COMPONENTS COME STANDARD ON ALL MODELS

MEMBRANE FILTRATION EQUIPMENT IS FACTORY-INSTALLED AND WET TESTED FOR A MINIMUM OF 24 HOURS ELECTRICAL PANEL AND CONTROLS SYSTEM ARE FACTORY-INSTALLED AND TESTED

25,000 GPD UNIT SHOWN 31.3’ L X 10’ W X 10’ H Prior to delivery, clients will be given exact connection points for power, communication, influent, effluent and WAS. AND TESTED THIS MODEL CAN RECLAIM 100% OF THE TREATED EFFLUENT

13 CLOACINA.COM [email protected] 888.483.8469 PRODUCT DESCRIPTION

TYPICAL INFLUENT PARAMETERS (1,000 - 500,000 GPD) The MEMPAC-M Membrane Bio Reactor (MBR) is a CONSTITUENT CONCENTRATION UNITS NOTES package wastewater treatment plant custom LIMIT designed and engineered for municipal clients with TSS 300 mg/L stringent discharge requirements or the desire to reclaim treated effluent for irrigation or land BOD5 <400 mg/L application purposes. Cloacina’s MEMPAC-M Temperature 5• - 20• •C Average integrates activated sludge and membranes for TN <70 mg/L clarification as the final stage of treatment. Unlike activated sludge wastewater treatment plants that utilize a traditional clarifier, membrane treatment TYPICAL EFFLUENT PARAMETERS does not allow solids to carry over into the final LIMITATIONS CONCENTRATION UNITS NOTES effluent. The MEMPAC-M is designed to treat LIMIT today’s higher-strength domestic influent to meet pH 6.0 - 8.5 strict discharge requirements and the standards for re-use. Tankage and equipment skids are BOD5 <10 mg/L fabricated from stainless steel and all interior and TSS <10 mg/L exterior components are fabricated from high- quality, corrosion-resistant materials. Prior to TN <10 mg/L shipping, all equipment is factory-installed and wet tested for a minimum of 24 hours. The TYPICAL APPLICATIONS compact design of the MEMPAC-M makes it ideal for municipal projects with small footprints and Municipal waste from mobile home parks, rest areas, campgrounds, schools, remote locations. detention centers and housing developments

CLOACINA.COM [email protected] 888.483.8469 14 MEMPACTM-R

ALL SENSORY EQUIPMENT IS MOUNTED ON THE CLOACINA SLIDE RAIL SYSTEM MEMBRANE FILTRATION EQUIPMENT IS FACTORY-INSTALLED AND WET TESTED FOR A MINIMUM OF 24 HOURS

ALL EQUIPMENT IS FACTORY-INSTALLED AND WET TESTED FOR A MINIMUM OF 24 HOURS

SEMI-SOUND ATTENUATED BLOWERS

CORROSION RESISTANT 304 STAINLESS STEEL TANKAGE AND COMPONENTS COME STANDARD ON ALL MODELS

ELECTRICAL PANEL AND CONTROLS SYSTEM ARE FACTORY-INSTALLED AND TESTED

25,000 GPD UNIT SHOWN 28.5’ L X 10’ W X 10’ H Prior to delivery, clients will be given exact connection points for power, communication, influent, effluent and WAS.

THIS MODEL CAN RECLAIM 100% OF THE TREATED EFFLUENT

15 CLOACINA.COM [email protected] 888.483.8469 PRODUCT DESCRIPTION

TYPICAL INFLUENT PARAMETERS (1,000 - 1,000,000 GPD) The MEMPAC-R is a retrofit Membrane Bio Reactor (MBR) designed for clients with existing CONSTITUENT CONCENTRATION UNITS NOTES LIMIT wastewater treatment systems that are not currently meeting discharge requirements, those TSS 0 - 1,500 mg/L that are facing more stringent discharge BOD5 0 - 15,000 mg/L requirements or those desiring to lower sewer Temperature 5• - 20• •C Average surcharge fees. It is also an ideal solution for those clients that wish to reclaim treated effluent for TN 0 - 20 mg/L re-use or would like to increase the capacity of their current wastewater system while improving TYPICAL EFFLUENT PARAMETERS effluent quality. The MEMPAC-R treats wastewater using Activated Sludge with membranes for LIMITATIONS CONCENTRATION UNITS NOTES LIMIT clarification as the final stage of treatment prior to ultimate disposal. Modular design allows for easy pH 6.0 - 8.0 installation and incorporation of the Cloacina- BOD5 <10 mg/L supplied equipment and controls system into any existing wastewater treatment system. The TSS <10 mg/L MEMPAC-R includes all membrane equipment TN <10 mg/L necessary for treatment. Interior and exterior components are fabricated from high-quality, corrosion-resistant materials and all tanks are TYPICAL APPLICATIONS fabricated from stainless steel. All equipment is Appropriate to integrate into most types of wastewater treatment systems factory-installed and wet tested for a minimum of 24 hours prior to shipping.

CLOACINA.COM [email protected] 888.483.8469 16 DRYPACTM SLUDGE HANDLING SYSTEM

ALL SENSORY EQUIPMENT IS MOUNTED ON THE CLOACINA SLIDE RAIL SYSTEM AND IS ACCESSIBLE ELECTRICAL PANEL FROM THE INSPECTION PLATFORM AND CONTROLS SYSTEM ARE FACTORY-INSTALLED AND TESTED

INTEGRATED POYLMER HANDLING SYSTEM

ALUMINUM STAIRS AND ELEVATED PLATFORM(S)

CORROSION RESISTANT 304 STAINLESS STEEL TANKAGE AND COMPONENTS COME STANDARD ON ALL MODELS

SEMI-SOUND ATTENUATED BLOWERS ALL EQUIPMENT IS FACTORY-INSTALLED AND WET TESTED FOR A MINIMUM OF 24 HOURS

5,000 Gallons of Liquid Storage Shown 18.8’ L X 10’ W X 10’ H Prior to delivery, Cloacina will provide exact location of connection points for power, communication, influent and effluent.

THIS MODEL CAN RECLAIM 100% OF THE TREATED EFFLUENT

17 CLOACINA.COM [email protected] 888.483.8469 PRODUCT DESCRIPTION

TYPICAL PARAMETERS (100 - 100,000 GPD) Cloacina’s DRYPAC Aerated Sludge Handling System is designed to process Waste Activated Sludge (WAS) CONSTITUENT UNITS RANGE from a variety of treatment plants: Sequencing batch reactors, extended aeration, solids contact and Daily Flows Gallons Per Day 0 -100,0001 membrane bio-reactors. The WAS is transferred to Liquid Storage Gallons 500 - 30,0002 the liquid storage chamber either by existing pumps or Cloacina-supplied and integrated self-feeding Inlet Storage mg/L 500 - 50,0003 pumps. The sludge is periodically aerated with an Outlet Percent Solids % 5% - 25%4 integrated semi-sound attenuated blower utilizing medium bubble diffusers for freshening and odor 1 HIGHER FLOWS AVAILABLE mitigation. Once the level has reached the ON 2 ADDITIONAL LIQUID STORAGE AVAILABLE set-point, the automated sludge processing 3 CONTACT CLOACINA FOR CUSTOM SOLIDS RANGES equipment is fed with a self-priming sludge feed 4 VARIES BASED ON APPLICATION pump. The filtrate is returned to the plant headworks or disposal area. The pressed solids are disposed of in TYPICAL APPLICATIONS a client-provided dumpster, roll-off or custom bin, depending on the client’s application. All necessary Any producer of liquid sludge desiring to reduce disposal costs through chemical/polymer addition equipment is provided as on-site de-watering part of the system and integrated into the overall controls system which can be accessed remotely. All equipment is designed to be easily operated and maintained and is positioned for ease of access. Clients may request the standard volute dewatering press or choose from industry standard sludge processing equipment such as centrifuges, rocker presses, belt presses or sludge baggers to suit their individual needs.

CLOACINA.COM [email protected] 888.483.8469 18 SLIDE RAILTM SYSTEM

. DISSOLVED OXYGEN (DO) PROBE . MIXED LIQUOR . SUSPENDED LEVEL TRANSDUCER SOLIDS (MLSS) METER

FRONT VIEW SIDE VIEW . .

UPPER MOUNT . UPPER MOUNT . CABLE LOOP .

PROBE STOP PROBE STOP SUPPORT CABLE SUPPORT CABLE . SLIDE STOP . PROBE SLIDE SLIDE STOP LOWER MOUNT . . LOWER MOUNT . . . PROBE SLIDE .

19 CLOACINA.COM [email protected] 888.483.8469 PRODUCT DESCRIPTION

TYPICAL APPLICATIONS The patented Cloacina Slide Rail System provides Single probes, sensors and analytics mounting and support of equipment requiring Multiple probes, sensors and analytics precise installation and repeated removal for Pumps (Less than 50 lbs.) calibration and maintenance. This system is designed to be used with any popular threaded Screens sensory equipment (Custom clamp applications Suction lines are available for non-threaded connections). Float brackets Strain relief The Cloacina Slide Rail System allows multiple Hangers/hooks pieces of equipment to be installed in a tight space without tension on or tangling of power cords and STANDARD FEATURES controls cables. All components are manufactured Each Cloacina Slide Rail System comes with the equipment slide (Designed to from non-corrosive materials. fit client’s probe, float, screen, pump etc.) and upper and lower hardware. Stainless steel upper and lower mounting UPGRADES AND OPTIONS hardware allows for vertical or horizontal Stainless steel anchors orientations on any mounting surface. The Custom equipment slides equipment slide attaches to probes, sensors, small Lifting cable in 1’ increments with cable clamps pumps (Less than 50 lbs.) suction hoses and wire harnesses. Maintenance pedestal Equipment stop Clients provide Cloacina with the project Slide lock speci cations and a Slide Rail System is custom designed to t the application. ORDERING INFORMATION Each Cloacina Slide Rail System is custom made to order. Please email [email protected] or visit cloacina.com for more information.

CLOACINA.COM [email protected] 888.483.8469 20 CONTROLS SYSTEM

THE MOST ADVANCED PACKAGE WASTEWATER TREATMENT PLANT CONTROLS SYSTEM CURRENTLY AVAILABLE

Graphical representation of the entire treatment process Controls all equipment and processes Provides user-defined set points Alarm condition notifications via text/email Operator can enter/record information Graphs can show only desired parameters Stainless steel controls system panels* Industrial-grade touch screen monitors Varying levels of user access Can be integrated into existing controls system or stand alone Access from any device with an Internet connection Circuitry is protected by properly sized breakers and fuses Magnetic starters/switches/VFDs control all electro-mechanical components Can be wired for any site voltage

*On all models except the MEMPAC-E

CLOACINA’S CONTROLS SYSTEM AUTOMATICALLY GENERATES: Equipment maintenance due dates based on elapsed run times Maintenance status reports A daily report on all monitored parameters A daily event and alarm condition report

21 CLOACINA.COM [email protected] 888.483.8469 SCOPE OF SUPPLY FOR ALL MODELS

STANDARD FEATURES OPTIONAL FEATURES 304 stainless steel tankage Buried installation with internal lift station, influent screen and flow meter All bases, skids and supports are 304 stainless pH adjustment system Stainless steel controls panels (Excluding MEMPAC-E) Cutting-edge controls system Denitrification Influent screening Disinfection Membrane cassette(s) Package lift station Semi-sound-attenuated, positive displacement Prefabricated controls building blowers Sludge disposal equipment Modular medium bubble diffusers Incorporation of existing controls equipment into All sensory equipment is mounted on Cloacina’s Cloacina’s controls package patented Slide Rail™ System Energy saving controls system upgrades Above-ground installation Equalization Human Machine Interface (HMI) Additional equipment sound attenuation All piping, valves and fittings will be a minimum of Thermal protection Schedule 80 PVC Mobile units Automated Clean In Place (CIP) system Odor mitigation equipment Automated foam control MORE STANDARD FEATURES Sediment/grit traps THAN ANY OTHER SYSTEM! A variety of grating, covers and awnings are available Project management and equipment installation

CLOACINA.COM [email protected] 888.483.8469 22 FACTORY TESTING

ALL CLOACINA PACKAGE PLANTS MUST PASS RIGOROUS FACTORY TESTS:

All tankage is checked to ensure it is constructed to the exact specifications of the drawings All inside and outside welds are checked and determined to be leak free All interior tank compartments are determined to be leak free All pipe penetrations are determined to be leak free All tank compartments are cleaned and determined to be leak free All welds are cleaned and passivated (Cloacina uses a chemical and electrical passivation process) All exterior walls are determined to be leak free All exterior penetrations are determined to be leak free All electrical equipment is rotation tested All electrical equipment full load amps are verified and recorded for baseline establishment All tank compartments are determined to be free of slag and then passivated inside Controls system alarms, trending, notifications and set-points are verified and recorded If applicable, the hatch door is assembled and is determined to be leak free All exterior welds on the tank are brushed and are free of spatter and slag All manual processes are performed and adjusted for ease of operation Initial set-points for all equipment are logged

EVERY CLOACINA PACKAGE PLANT IS WET TESTED FOR A MINIMUM OF 24 HOURS PRIOR TO PACKING AND SHIPPING

23 CLOACINA.COM [email protected] 888.483.8469 INSTALLATION

MAJOR STEPS TO INSTALL A CLOACINA WASTEWATER TREATMENT PLANT:

The Cloacina plant is transported to the job site Off-loading with a crane or large forklift(s) Placement on the slab Depending on the system size, minor components may have been removed for shipping purposes and will require re-assembly (All removed components are match marked for quick re-installation) System interconnects (Inlets/outlets) are made Electrical connections are made Internet connection is made

INSTALLS UP TO 50% SHIPS ON A DESIGNED TO BE FASTER THAN OTHER LOWBOY TRAILER EASILY INSTALLED TREATMENT SYSTEMS

CLOACINA.COM [email protected] 888.483.8469 24 START-UP AND COMMISSIONING

EVERY CLOACINA PACKAGE PLANT IS WET TESTED FOR A MINIMUM OF 24 HOURS BEFORE LEAVING THE FACTORY. WET TESTING OCCURS AFTER ALL MECHANICAL EQUIPMENT IS INSTALLED. TANKS ARE FILLED TO NORMAL OPERATING DEPTHS, THE ENTIRE SYSTEM IS OPERATED AND ALL CONTROLS SET POINTS ARE TESTED AND VERIFIED. FACTORY TESTING EXPEDITES THE ON-SITE START-UP AND COMMISSIONING PROCESS WHICH INCLUDES:

On-site electrical verification/rotation check UP TO Potable water filled to operating level in all chambers Pressure tests of all interconnects 24 hour minimum forward flow test Introduction and stabilization of seed sludge 70% Introduction of raw influent REDUCTION IN ON-SITE Stabilization and testing of effluent START-UP COSTS OVER Operations staff training OTHER TREATMENT SYSTEMS

25 CLOACINA.COM [email protected] 888.483.8469 POST-INSTALLATION

Cloacina's involvement in a project does not end CUSTOMIZED AND PERSONAL when a client’s equipment leaves the factory. POST-INSTALLATION Post-installation customer service and client SUPPORT BY LICENSED support are important and included components of all Cloacina wastewater projects. We can also WASTEWATER OPERATORS provide additional post-installation support*: OPTIONAL POST INSTALLATION SERVICES OFFERED ScanualTM--Cloacina’s digital O&M manual with corresponding QR codes and equipment tags Daily, weekly or monthly proactive monitoring of system set-points, graphs, alarms and providing written reports to the client on an ongoing basis Routine maintenance: Cloacina can provide monthly, quarterly and annual maintenance services Compliance reports: Cloacina can review, prepare and submit all reporting documents to local, state and federal regulatory agencies Plant expansions: Cloacina is available to assist in the design and construction of any plant upgrades 24/7 Assistance: Cloacina can provide the client with access to their 24/7 customer service hotline Remote access troubleshooting: Provided the Internet connection has been maintained, Cloacina programmers and operations staff can remotely access a facility to assist with troubleshooting *These services can be provided for an additional fee -- please contact Cloacina for an estimate.

CLOACINA.COM [email protected] 888.483.8469 26