3115 SAPS Operating Instructions
Total Page:16
File Type:pdf, Size:1020Kb
OPERATING INSTRUCTIONS FIELD PLANT WATER STATUS CONSOLE March 2017 Fig. 1 - Model 3115 Portable Plant Water Console shown with 22 c/f Compressed Gas Cylinder, 3072V22 SOILMOISTURE EQUIPMENT CORP. P.O. Box 30025, Santa Barbara, CA 93105 U.S.A. Telephone 805-964-3525 - Fax No. 805-683-2189 Email: [email protected] - Website: http://www.soilmoisture.com Table of Contents Chapter - Page 1 Description ............................................................................................................................... 1 - 4 2 Technical Specification ............................................................................................................ 2 - 5 2.1 Weight .......................................................................................................................... 2 - 5 2.2 Dimensions ................................................................................................................... 2 - 5 2.3 Pressure Vessel ............................................................................................................. 2 - 5 2.4 Gauges .......................................................................................................................... 2 - 5 2.5 Valves ........................................................................................................................... 2 - 5 2.6 Connecting Hose .......................................................................................................... 2 - 5 2.7 Pressure Tank ............................................................................................................... 2 - 5 2.8 Specimen Holder .......................................................................................................... 2 - 5 3 Accquaint yourself with Model 3115 ....................................................................................... 3 - 6 3.1 Specimen Holder Assembly ......................................................................................... 3 - 6 3.2 Sealing Sleeves, Grommets, and Support Washers ...................................................... 3 - 7 3.3 Gauges .......................................................................................................................... 3 - 7 3.4 Pressure Regulator ........................................................................................................ 3 - 7 3.5 Metering Valve ............................................................................................................. 3 - 7 3.6 3-Way Pressure Control Valve ..................................................................................... 3 - 8 3.7 Sample Preparation Board ............................................................................................ 3 - 8 3.8 Quick Connect Inlet Pressure Port ............................................................................... 3 - 8 3.9 Use the Standard Cylinder ............................................................................................ 3 - 8 3.10 High Presure Braided Steel Quick Connect ................................................................. 3 - 8 3.11 4.5" deep Stainless Steel Pressure Vessel ..................................................................... 3 - 9 4. Using Your New PPWS for the first time ............................................................................... 4 - 10 4.1 Select a convenient platform from which to make your measurements .................... 4 - 10 4.2 Check teh 3-Way Valve on the 3115 Control Panel ................................................... 4 - 10 4.3 Attach the Quick Connect Hose ................................................................................. 4 - 10 4.4 With the Quick conect fitting attached to the console ................................................ 4 - 10 4.5 Remove the Specimen Holder Assembly ....................................................................4 - 11 4.6 Remove the sealing knob ............................................................................................4 - 11 4.7 Make a leaf or stem water potential measurement ......................................................4 - 12 4.8 Insert Specimen Holder ...............................................................................................4 - 13 4.9 Next turn the 3-way control valve ...............................................................................4 - 13 4.10 Use a Hand lens or magnifying glass ..........................................................................4 - 14 4.11 The proper end-point ...................................................................................................4 - 14 4.12 Finally, remove the used leaf .......................................................................................4 - 15 4.13 Reminder .....................................................................................................................4 - 15 SOILMOISTURE EQUIPMENT CORP. 2 P.O. Box 30025, Santa Barbara, CA 93105 U.S.A. Telephone 805-964-3525 - Fax No. 805-683-2189 Email: [email protected] - Website: http://www.soilmoisture.com 5 General Maintenance ................................................................................................................5 - 15 5.1 Refilling the Compressed Gas Source Tank .................................................................5 - 15 5.2 Refill the Compressed gas bottle yourself ....................................................................5 - 17 5.3 Check for leaks .............................................................................................................5 - 17 5.4 Cleaning and Maintenance ...........................................................................................5 - 19 5.5 Remove/replace the sealing sleeve ...............................................................................5 - 19 5.6 Re-set the Needle pointer .............................................................................................5 - 19 5.7 Repair/up-grade the specimen holder ...........................................................................5 - 20 5.8 Repair/replace the helicoil insert ..................................................................................5 - 21 6 Replacement & Accessory Parts for the 3115 ..........................................................................6 - 22 7. Appendix ..................................................................................................................................7 - 24 8. References ................................................................................................................................8 - 28 SOILMOISTURE EQUIPMENT CORP. 3 P.O. Box 30025, Santa Barbara, CA 93105 U.S.A. Telephone 805-964-3525 - Fax No. 805-683-2189 Email: [email protected] - Website: http://www.soilmoisture.com Model 3115 Portable Plant Water Status Console OPERATING INSTRUCTIONS 1. 3115 Portable Plant Water Status Console The PPWS Console, Model 3115, is supplied in water and dust proof Pelican instrument case. The 3115 can be configured as a 25 or 40 bar (25 or 40 Mpa) platform with either the G4 or G2 specimen holder (for petioles and stems to ½” (125 mm), or blade leaves to 1” (254 mm) respectively. Choose either the standard 22 cu. ft. capacity or purchase the optional 33 cu. ft. capacity compressed gas bottle, for a small additional cost. The 3115 uses a quick-connect/disconnect, hose with stainless steel braids, and an external Pressure Regulator, preset at Fig. 1 Portable Plant the factory for the maximum operating pressure of 40 bar (4.0 MPa) or 25 bar Water status console (2.5 MPa). (see Fig. 1) The PPWS Console was thoroughly tested before shipment. When packed, it was in perfect working order. Unpack with care and remove all packing material. Follow the instructions carefully in order to assure long, trouble-free service. Any damage found upon receipt should be reported immediately to the transport carrier for claim. It is important to save the shipping container and all evidence to support your claim. Be sure to read all operating instructions thoroughly before operating the unit. Soilmoisture Equipment Corp. (SEC) warrants all products manufactured by SEC to be free from defects in materials and workmanship under normal use and service for twelve (12) months from the date of invoice subject to the following conditions: SEC’s obligation under this warranty is limited to repairing or replacing (at SEC’s option) products which have been returned prepaid to SEC or SEC’s agent in the user’s country. SEC will return warranted equipment prepaid. This warranty shall not apply to any SEC products which have been modified, misused, neglected, involved in accidents of nature, or sustained shipping damage. Under no circumstances will SEC reimburse the claimant for costs incurred in removing and/or reinstalling equipment. This warranty, and SEC’s obligation thereunder, is in lieu of all other warranties, expressed or implied, including warranties of suitability and fitness for a particular purpose. SEC is not responsible for incidental or consequential damages, actual or inferred, caused by misuse or improper handling of its products. SEC products are designed to be used solely as described in the product operating instructions by a prudent individual under normal conditions in applications intended for each product. Products returned to SEC should have a Return Merchandise Authorization (RMA) number