Download This Article As a PDF File
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
1) What Is the Name of an Ethernet Cable That Contains Two
1) What is the name of an Ethernet cable that contains two electrical conductors ? A coaxial cable 2) What are the names of the two common conditions that degrade the signals on c opper-based cables? Crosstal and attenuation 3) Which topology requires the use of terminators? Bus 4) Which of the following topologies is implemented only logically, not physical ly? Ring 5) How many wire pairs are actually used on a typical UTP Ethernet network? Two 6) What is the name of the process of building a frame around network layer info rmation? Data encapsulation 7) Which of the connectors on a network interface adapter transmits data in para llel? The System bus connector 8) Which two of the following hardware resources do network interface adapters a lways require? I/O port address and IRQ 9) What is the name of the process by which a network interface adapter determin es when it should transmit its data over the network? Media Access Control 10) Which bus type is preferred for a NIC that will be connected to a Fast Ether net network? PCI 11) A passive hub does not do which of the following? Transmit management information using SNMP 12) To connect two Ethernet hubs together, you must do which of the following? Connect the uplink port in one hub to a standard port on the other 13) Which term describes a port in a Token Ring MAU that is not part of the ring ? Intelligent 14) A hub that functions as a repeater inhibits the effect of____________? Attenuation 15) You can use which of the following to connect two Ethernet computers togethe r using UTP -
Gigabit Ethernet - CH 3 - Ethernet, Fast Ethernet, and Gigabit Ethern
Switched, Fast, and Gigabit Ethernet - CH 3 - Ethernet, Fast Ethernet, and Gigabit Ethern.. Page 1 of 36 [Figures are not included in this sample chapter] Switched, Fast, and Gigabit Ethernet - 3 - Ethernet, Fast Ethernet, and Gigabit Ethernet Standards This chapter discusses the theory and standards of the three versions of Ethernet around today: regular 10Mbps Ethernet, 100Mbps Fast Ethernet, and 1000Mbps Gigabit Ethernet. The goal of this chapter is to educate you as a LAN manager or IT professional about essential differences between shared 10Mbps Ethernet and these newer technologies. This chapter focuses on aspects of Fast Ethernet and Gigabit Ethernet that are relevant to you and doesn’t get into too much technical detail. Read this chapter and the following two (Chapter 4, "Layer 2 Ethernet Switching," and Chapter 5, "VLANs and Layer 3 Switching") together. This chapter focuses on the different Ethernet MAC and PHY standards, as well as repeaters, also known as hubs. Chapter 4 examines Ethernet bridging, also known as Layer 2 switching. Chapter 5 discusses VLANs, some basics of routing, and Layer 3 switching. These three chapters serve as a precursor to the second half of this book, namely the hands-on implementation in Chapters 8 through 12. After you understand the key differences between yesterday’s shared Ethernet and today’s Switched, Fast, and Gigabit Ethernet, evaluating products and building a network with these products should be relatively straightforward. The chapter is split into seven sections: l "Ethernet and the OSI Reference Model" discusses the OSI Reference Model and how Ethernet relates to the physical (PHY) and Media Access Control (MAC) layers of the OSI model. -
Book IG 1800 British Telecom Rev A.Book
Notice to Users ©2003 2Wire, Inc. All rights reserved. This manual in whole or in part, may not be reproduced, translated, or reduced to any machine-readable form without prior written approval. 2WIRE PROVIDES NO WARRANTY WITH REGARD TO THIS MANUAL, THE SOFTWARE, OR OTHER INFORMATION CONTAINED HEREIN AND HEREBY EXPRESSLY DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WITH REGARD TO THIS MANUAL, THE SOFTWARE, OR SUCH OTHER INFORMATION, IN NO EVENT SHALL 2WIRE, INC. BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL, OR SPECIAL DAMAGES, WHETHER BASED ON TORT, CONTRACT, OR OTHERWISE, ARISING OUT OF OR IN CONNECTION WITH THIS MANUAL, THE SOFTWARE, OR OTHER INFORMATION CONTAINED HEREIN OR THE USE THEREOF. 2Wire, Inc. reserves the right to make any modification to this manual or the information contained herein at any time without notice. The software described herein is governed by the terms of a separate user license agreement. Updates and additions to software may require an additional charge. Subscriptions to online service providers may require a fee and credit card information. Financial services may require prior arrangements with participating financial institutions. © British Telecommunications Plc 2002. BTopenworld and the BTopenworld orb are registered trademarks of British Telecommunications plc. British Telecommunications Plc registered office is at 81 Newgate Street, London EC1A 7AJ, registered in England No. 180000. ___________________________________________________________________________________________________________________________ Owner’s Record The serial number is located on the bottom of your Intelligent Gateway. Record the serial number in the space provided here and refer to it when you call Customer Care. Serial Number:__________________________ Safety Information • Use of an alternative power supply may damage the Intelligent Gateway, and will invalidate the approval that accompanies the Intelligent Gateway. -
Ethernet/Category 5 Network Cabling Guide Prepared by SJ Wilkinson (August 2002) Based on Steve Derose’S Guide to CAT5 Network Wiring (See Later Web Reference)
Ethernet/Category 5 Network Cabling Guide Prepared by SJ Wilkinson (August 2002) Based on Steve DeRose’s Guide to CAT5 Network Wiring (See later Web Reference) Networks A Local Area Network (LAN) can be as simple as two computers, each having a network interface card (NIC) or network adapter and running network software, connected together with a crossover cable. Here the crossover cable would have a plug at either end to connect into the NIC socket at the back of each computer. The next step up would be a network consisting of three or more computers and a hub. Each of the computers is plugged into the hub with a straight-thru cable (the crossover function is performed by the hub). For a small network the straight-thru cables would have plugs at either end – one to connect to the computer and one to the hub. For larger networks wall cabling, wall sockets and patch cables are used. A CAT5 "patch panel" is used at the hub end where all your wires come together and provides a group of sockets for further cables. Straight-thru patch cables connect computers to sockets (jacks). Straight-thru wall cables connect sockets to the patch panel. Straight-thru patch cables connect the patch panel to the hub. Patch panels often make network cabling neater but are not essential as (a) wiring a plug is no harder than wiring a panel; (b) you still need cables to go from the panel to the hub; and (c) it adds extra connections, so lowers reliability. 1 Planning your Network Pick a location for your hub, preferably centred to keep cable runs shorter. -
IEEE Paper Template in A4
Volume 6, Issue 2, February 2016 ISSN: 2277 128X International Journal of Advanced Research in Computer Science and Software Engineering Research Paper Available online at: www.ijarcsse.com A Review Paper on Cable Connectors Jhankar Tyagi Guest Faculty, Shaheed Sukhdev College of Business Studies, Delhi University, Delhi, India Abstract— This paper is an attempt to give a basic knowledge of cable connectors to the user. Keywords— Cable glands, RJ 45 Connector, Banana Connector, BNC Connector, XLR Connector I. INTRODUCTION An electrical connector is an electro-mechanical device for joining electrical circuits as an interface using a mechanical assembly. Connectors consist of plugs (male-ended) and jacks (female-ended). In computing, an electrical connector can also be known as a physical interface. II. PROPERTIES OF CONNECTORS Electrical connectors are characterized by their pin out and physical construction, ruggedness and resistance to vibration, resistance to entry of water or other contaminants, resistance to pressure, lifetime .They may be keyed to prevent insertion in the wrong orientation. It is usually desirable for a connector to be easy to identify visually, rapid to assemble, and be inexpensive .No single connector has all the ideal properties. Cable Glands: Cable glands known as cable connectors, connect wires to devices mechanically rather than electrically and are distinct from quick-disconnects .They are mechanical cable entry devices and can be constructed from metallic or non-metallic materials. They are used in conjunction with cable and wiring used in electrical instrumentation and automation systems. They are used as a ceiling and a termination device to insure that the characteristic of the enclosure which the cable enters can be contained adequately. -
Manual Will Indicate Which Sections Apply to the Different Programming Modes and Setups
INSTALLATION INSTRUCTIONS MX88 EIGHT ZONE – EIGHT SOURCE AUDIO & AUDIO/VIDEO CONTROLLER/AMPLIFIER Page: 2 Model MX88 IMPORTANT SAFETY INSTRUCTIONS - READ BEFORE OPERATING EQUIPMENT CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of un-insulated “dangerous voltage” within the product‟s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. This product was designed and manufactured to meet strict quality and safety standards. There are, however, some installation and operation precautions, which you should be particularly aware of. 1. Read Instructions – All the safety and operating instructions should be read before the appliance is operated. 2. Retain Instructions – The safety and operating instructions should be retained for future reference. 3. Heed Warnings – All warnings on the appliance and in the operating instructions should be adhered to. 4. Follow Instructions – All operating and use instructions should be followed. 5. Water and Moisture – The appliance should not be used near water – for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc. 6. -
Whitepaper: Understanding Ethernet Patch Cords in Modern Networks
Intelligently Designed Rack and Cable Management UNDERSTANDING ETHERNET PATCH CORDS IN MODERN NETWORKS Louis Chompff - Founder & Managing Director © 2020 AnD Cable Products Inc. andcable.com UUNDERSTANDINGNDERSTANDING EETHERNETTHERNET PPATCHATCH CCORDSORDS IN MMODERNODERN NENETWORKSTWORKS Copyright ©AnD Cable Products Inc. 2020. All Table of Contents rights reserved. This whitepaper and its content is 1. Ethernet Patch Cords and RJ-45 Connectors 3 copyright of AnD Cable Products Inc. Any redistribution or reproduction of part or all of the contents in any form is 2. Ethernet Patch Cords and UTP Cabling 4 prohibited other than the following: • you may print or locally download for 3. What’s All the Twisting About? 5 your personal and non-commercial use only • you may copy the content to individual 4. Ethernet Applications 7 third parties for their personal use, but only if you acknowledge AnD Cable 5. 568A and 568B Wiring Standards 7 Products Inc. as the source of the material You may not, except with our express written 5.1 Beware of Copper Clad Aluminum 8 permission, distribute or commercially exploit (CCA) Cables the content. Nor may you transmit it or store it in any other website or other form of electronic retrieval system. 6. Which One to Use? 10 7. Straight-Through and Crossover Cables 10 7.1 Data Communications Equipment (DCE) 12 and Data Terminal Equipment (DTE) 8. Glossary 14 About the Author 15 Celebrating over 30 years’ experience in the Manufacture and Supply of Cable Management and Rack Management Products andcable.com UUNDERSTANDINGNDERSTANDING EETHERNETTHERNET PPATCHATCH CCORDSORDS IINN MMODERNODERN NNETWORKSETWORKS Ethernet patch cables have modular characteristics and some important differences that can limit their interchangeability. -
Adslme1 User Guide.Qxd
Instant BroadbandTM Series ADSL Ethernet Modem Use this guide to install the following: Model No.: ADSLME1 User Guide COPYRIGHT & TRADEMARKS Copyright© 2001 Linksys, All Rights Reserved. Instant Broadband is a registered trade- mark of Linksys. Microsoft, Windows, and the Windows logo are registered trademarks of Microsoft Corporation. All other trademarks and brand names are the property of their respective proprietors. LIMITED WARRANTY Linksys guarantees that every Instant Broadband ADSL Ethernet Modem is free from physical defects in material and workmanship for one year from the date of purchase, when used within the limits set forth in the Specification section of this User Guide. If these products prove defective during this warranty period, call Linksys Customer Support in order to obtain a Return Authorization Number. BE SURE TO HAVE YOUR PROOF OF PURCHASE AND A BARCODE FROM THE PRODUCT'S PACKAGING ON HAND WHEN CALLING. RETURN REQUESTS CANNOT BE PROCESSED WITHOUT PROOF OF PURCHASE. When returning a product, mark the Return Authorization Number clearly on the outside of the package and include your original proof of pur- chase. All customers located outside of the United States of America and Canada shall be held responsible for shipping and handling charges. IN NO EVENT SHALL LINKSYS’ LIABILITY EXCEED THE PRICE PAID FOR THE PROD- UCT FROM DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAM- AGES RESULTING FROM THE USE OF THE PRODUCT, ITS ACCOMPANYING SOFT- WARE, OR ITS DOCUMENTATION. LINKSYS DOES NOT OFFER REFUNDS FOR ANY PRODUCT. Linksys makes no warranty or representation, expressed, implied, or statuto- ry, with respect to its products or the contents or use of this documentation and all accompanying software, and specifically disclaims its quality, performance, mer- chantability, or fitness for any particular purpose. -
Datacomm Products and Equipment Catalog
DataComm Products and Equipment Catalog IDEAL DataComm 112060_DataComm08_COVER.indd2060_DataComm08_COVER.indd 2 11/8/08/8/08 99:41:29:41:29 AAMM The way every job should be IDEAL DataComm is dedicated to helping low voltage/datacomm professionals keep networks up and running. The system of products we have thoughtfully crafted ensures the highest-quality terminations with the ease-of-use you would expect from IDEAL. Our DataComm line includes a system solution for paired conductor, coax and fiber optic cabling. www.idealindustries.com Paired Conductor Products Wire Cutters . A-2 A Wire Strippers . .A-2 Crimp Tools . A-4 Punch Down Tools . A-5 Tool and Connector Kits . A-5 Wall Plates . A-9 Cables . .A-10 Connectors . A-10 Coaxial Termination Products Tool Selection Chart . B-2 B Wire Cutters . B-3 Wire Strippers . B-3 Crimp Tools . B-4 Compression Tools . .B-6 Connectors . B-7 Splitters . .B-8 Wall Plates . B-8 Tool and Connector Kits . B-9 BNC Coaxial Connectors . .B-12 Fiber Optic Products Wire Strippers . C-2 C Fiber Optic Accessories . C-3 Table of Contents Table Test Equipment Qualification Testers . .D-2 D Certification Testers . D-4 Hand-Held Testers . D-7 Related Products Resources . E-1 E Multi Media Installation Guide . .E-3 Technical Information . .E-12 Residential Coax Application Guide . .E-13 Index Alphabetical Index . F-1 F Catalog Number Index . F-3 For applicable GSA Contracts — contact IDEAL at 800-947-3614 New Products Mini Coax Stripper Grounding Block Q Adjustable stripper for Q Solid zinc alloy, mini coax cable nickel plated and Page B-3 chromate finished Page B-8 OmniSeal™ Pro Compression Tools Q Compression tools now offer additional features and increased connector Compression Connector compatibility Installation Kit Page B-6 Q Three tools in one handy pouch that clips easily to your belt. -
Lan.Wiring.Jim.Trulove.Pdf
LAN Wiring This page intentionally left blank LAN Wiring Third Edition James Trulove McGraw-Hill New York Chicago San Francisco Lisbon London Madrid Mexico City Milan New Delhi San Juan Seoul Singapore Sydney Toronto Copyright © 2006 by James Trulove. All rights reserved. Manufactured in the United States of America. Except as permit- ted under the United States Copyright Act of 1976, no part of this publication may be reproduced or distributed in any form or by any means, or stored in a database or retrieval system, without the prior written permission of the publisher. 0-07-148345-4 The material in this eBook also appears in the print version of this title: 0-07-145975-8. All trademarks are trademarks of their respective owners. Rather than put a trademark symbol after every occurrence of a trademarked name, we use names in an editorial fashion only, and to the benefit of the trademark owner, with no intention of infringement of the trademark. Where such designations appear in this book, they have been printed with initial caps. McGraw-Hill eBooks are available at special quantity discounts to use as premiums and sales promotions, or for use incor- porate training programs. For more information, please contact George Hoare, Special Sales, at george_hoare@mcgraw- hill.com or (212) 904-4069. TERMS OF USE This is a copyrighted work and The McGraw-Hill Companies, Inc. (“McGraw-Hill”) and its licensors reserve all rights in and to the work. Use of this work is subject to these terms. Except as permitted under the Copyright Act of 1976 and the right to store and retrieve one copy of the work, you may not decompile, disassemble, reverse engineer, reproduce, modify, create derivative works based upon, transmit, distribute, disseminate, sell, publish or sublicense the work or any part of it without McGraw-Hill’s prior consent. -
KNOW the LINGO – WHAT IS Category CABLE?
KNOW THE LINGO – WHAT IS CategoRY CABLE? By: Joseph D. Cornwall, CTS-D Technology Evangelist—Lastar, Inc. Technical lingo is a kind of shorthand that’s used to express concepts common to that specific topic or area of study. Technical lingo is important because it provides a very precise or unique “shorthand” description of a device, effect or concept. Unfortunately, if you aren’t comfortable and familiar with the lingo of a topic it can be a tall hurdle to communicate efficiently with folks who consider the jargon of their field to be “self-explanatory.” In this series of articles we’ll lift the veils of misunderstanding from the lingo of the A/V industry. WHAT IS A CAT CABLE? The concept of Category cables was first set forth by the Electronic Industries Alliance (EIA) and is now maintained by the Telecommunications Industry Association (TIA). In 1991 the TIA/EIA-568-A standard was released (now revised to TIA/EIA-568-C) in an effort to define standards for telecommunications installations. In particular, the standard worked to define elements of balanced twisted pair cabling, fiber optic cabling and coaxial cabling, along with the associated connectors. The Cat cables discussed here are of the unshielded twisted pair (UTP) variety. You can’t be in the A/V or IT industry and not have heard of Cat5e and Cat6 cables. The Cat, as you might know, is short for “Category.” The term “Category” refers to the different levels of performance in signal bandwidth, attenuation and crosstalk associated with each cable’s design. -
MODEM 32Fast
JANUARY 1995 MD855A-R2 MODEM 32Fast 34336 MODEM ENT 3 2 1 3 2 1 CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 INFORMATION Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: [email protected] MODEM 32Fast FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENT This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This digital apparatus does not exceed the Class A limits for Radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par Industrie Canada.