MODEM 32Fast

Total Page:16

File Type:pdf, Size:1020Kb

MODEM 32Fast JANUARY 1995 MD855A-R2 MODEM 32Fast 34336 MODEM ENT 3 2 1 3 2 1 CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 INFORMATION Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: [email protected] MODEM 32Fast FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENT This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This digital apparatus does not exceed the Class A limits for Radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par Industrie Canada. TRADEMARKS AT&T® is a registered trademark of AT&T. BitCom® is a registered trademark of Bit Software, Inc. SideKick® is a registered trademark of Inprise Corporation. ProComm® is a registered trademark of Symantec Corporation. CrossTalk® is a registered trademark of Attachmate Corporation. VT100™ is a trademark of Compaq Computer Corporation. Hayes®, SmartCom II®, and SmartCom III® are registered trademarks, and Smartmodem 2400™ is a trademark, of Hayes Microcomputer Products, Inc. PC-TALK® is a registered trademark of Headlands Press, Inc. IBM®, AS/ADD®, AT®, and NetView® are registered trademarks of IBM Corporation. Microcom Networking Protocol® and MNP® are registered trademarks of Microcom Systems, Inc. SmarTerm® is a registered trademark of Persoft, Inc.— An Esker Company. RELAY Gold® is a registered trademark of VM Personal Computing. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners. 1 MODEM 32Fast Table of Contents 1. Specifications......................................................................................................................................................6 2. Introduction .......................................................................................................................................................8 2.1 Front Panel Operation .............................................................................................................................8 2.2 Option Sets................................................................................................................................................8 2.3 Extended DTE Rates ................................................................................................................................8 2.4 Synchronous Data Compression (SDC)..................................................................................................9 2.5 Network Management..............................................................................................................................9 2.6 Restoral......................................................................................................................................................9 2.7 Automode/Multimode.............................................................................................................................9 2.8 AT Commands ..........................................................................................................................................9 2.9 V.25 bis ACU .............................................................................................................................................9 2.10 LPDA2 .....................................................................................................................................................10 2.11 Remote Configuration ...........................................................................................................................10 2.12 Security....................................................................................................................................................10 2.13 Status Snapshots .....................................................................................................................................10 2.14 Adaptive Rate System .............................................................................................................................10 2.15 Troubleshooting (V.54 and V.22 bis Tests)............................................................................................10 3. Installation ........................................................................................................................................................11 3.1 Unpacking Your Modem........................................................................................................................11 3.2 Choosing a Site .......................................................................................................................................11 3.3 FCC Registration.....................................................................................................................................11 3.4 Rear-Panel Layout...................................................................................................................................11 3.5 Cabling Your Modem .............................................................................................................................12 3.5.1 Connecting to a DTE ...................................................................................................................12 3.5.2 Connecting the Modem to a Dial Line .......................................................................................13 3.5.3 Attaching a Ferrite Cable for Dial-Line Connection..................................................................13 3.5.4 Connecting the Modem to a Leased Line ..................................................................................14 3.5.5 Connecting the Modem to a PBX ...............................................................................................14 3.6 Connecting to an AC Outlet..................................................................................................................14 4. Getting Started .................................................................................................................................................15 4.1 Before You Begin ....................................................................................................................................15 4.2 Front-Panel Layout .................................................................................................................................15 4.3 Front-Panel LEDs....................................................................................................................................16 4.4 Front-Panel Display.................................................................................................................................17 4.5 Navigating the Front Panel Menu Tree.................................................................................................17 4.6 Remote Access Reset ..............................................................................................................................19 4.6.1 Operation......................................................................................................................................19 4.6.2 Cases in Which Remote Access Reset is Disabled.......................................................................20 4.7 Configuring for Your Application .........................................................................................................20 4.8 Option Sets..............................................................................................................................................20 4.9 Option Set Descriptions.........................................................................................................................21 4.10 How to Configure an Option Set ..........................................................................................................22 4.11 Option Set Defaults ................................................................................................................................22 4.12 SDC Applications....................................................................................................................................25 2 Table of Contents 4.13 SDC Pre-Operation Notes ......................................................................................................................25
Recommended publications
  • Book IG 1800 British Telecom Rev A.Book
    Notice to Users ©2003 2Wire, Inc. All rights reserved. This manual in whole or in part, may not be reproduced, translated, or reduced to any machine-readable form without prior written approval. 2WIRE PROVIDES NO WARRANTY WITH REGARD TO THIS MANUAL, THE SOFTWARE, OR OTHER INFORMATION CONTAINED HEREIN AND HEREBY EXPRESSLY DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WITH REGARD TO THIS MANUAL, THE SOFTWARE, OR SUCH OTHER INFORMATION, IN NO EVENT SHALL 2WIRE, INC. BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL, OR SPECIAL DAMAGES, WHETHER BASED ON TORT, CONTRACT, OR OTHERWISE, ARISING OUT OF OR IN CONNECTION WITH THIS MANUAL, THE SOFTWARE, OR OTHER INFORMATION CONTAINED HEREIN OR THE USE THEREOF. 2Wire, Inc. reserves the right to make any modification to this manual or the information contained herein at any time without notice. The software described herein is governed by the terms of a separate user license agreement. Updates and additions to software may require an additional charge. Subscriptions to online service providers may require a fee and credit card information. Financial services may require prior arrangements with participating financial institutions. © British Telecommunications Plc 2002. BTopenworld and the BTopenworld orb are registered trademarks of British Telecommunications plc. British Telecommunications Plc registered office is at 81 Newgate Street, London EC1A 7AJ, registered in England No. 180000. ___________________________________________________________________________________________________________________________ Owner’s Record The serial number is located on the bottom of your Intelligent Gateway. Record the serial number in the space provided here and refer to it when you call Customer Care. Serial Number:__________________________ Safety Information • Use of an alternative power supply may damage the Intelligent Gateway, and will invalidate the approval that accompanies the Intelligent Gateway.
    [Show full text]
  • Ethernet/Category 5 Network Cabling Guide Prepared by SJ Wilkinson (August 2002) Based on Steve Derose’S Guide to CAT5 Network Wiring (See Later Web Reference)
    Ethernet/Category 5 Network Cabling Guide Prepared by SJ Wilkinson (August 2002) Based on Steve DeRose’s Guide to CAT5 Network Wiring (See later Web Reference) Networks A Local Area Network (LAN) can be as simple as two computers, each having a network interface card (NIC) or network adapter and running network software, connected together with a crossover cable. Here the crossover cable would have a plug at either end to connect into the NIC socket at the back of each computer. The next step up would be a network consisting of three or more computers and a hub. Each of the computers is plugged into the hub with a straight-thru cable (the crossover function is performed by the hub). For a small network the straight-thru cables would have plugs at either end – one to connect to the computer and one to the hub. For larger networks wall cabling, wall sockets and patch cables are used. A CAT5 "patch panel" is used at the hub end where all your wires come together and provides a group of sockets for further cables. Straight-thru patch cables connect computers to sockets (jacks). Straight-thru wall cables connect sockets to the patch panel. Straight-thru patch cables connect the patch panel to the hub. Patch panels often make network cabling neater but are not essential as (a) wiring a plug is no harder than wiring a panel; (b) you still need cables to go from the panel to the hub; and (c) it adds extra connections, so lowers reliability. 1 Planning your Network Pick a location for your hub, preferably centred to keep cable runs shorter.
    [Show full text]
  • IEEE Paper Template in A4
    Volume 6, Issue 2, February 2016 ISSN: 2277 128X International Journal of Advanced Research in Computer Science and Software Engineering Research Paper Available online at: www.ijarcsse.com A Review Paper on Cable Connectors Jhankar Tyagi Guest Faculty, Shaheed Sukhdev College of Business Studies, Delhi University, Delhi, India Abstract— This paper is an attempt to give a basic knowledge of cable connectors to the user. Keywords— Cable glands, RJ 45 Connector, Banana Connector, BNC Connector, XLR Connector I. INTRODUCTION An electrical connector is an electro-mechanical device for joining electrical circuits as an interface using a mechanical assembly. Connectors consist of plugs (male-ended) and jacks (female-ended). In computing, an electrical connector can also be known as a physical interface. II. PROPERTIES OF CONNECTORS Electrical connectors are characterized by their pin out and physical construction, ruggedness and resistance to vibration, resistance to entry of water or other contaminants, resistance to pressure, lifetime .They may be keyed to prevent insertion in the wrong orientation. It is usually desirable for a connector to be easy to identify visually, rapid to assemble, and be inexpensive .No single connector has all the ideal properties. Cable Glands: Cable glands known as cable connectors, connect wires to devices mechanically rather than electrically and are distinct from quick-disconnects .They are mechanical cable entry devices and can be constructed from metallic or non-metallic materials. They are used in conjunction with cable and wiring used in electrical instrumentation and automation systems. They are used as a ceiling and a termination device to insure that the characteristic of the enclosure which the cable enters can be contained adequately.
    [Show full text]
  • Manual Will Indicate Which Sections Apply to the Different Programming Modes and Setups
    INSTALLATION INSTRUCTIONS MX88 EIGHT ZONE – EIGHT SOURCE AUDIO & AUDIO/VIDEO CONTROLLER/AMPLIFIER Page: 2 Model MX88 IMPORTANT SAFETY INSTRUCTIONS - READ BEFORE OPERATING EQUIPMENT CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of un-insulated “dangerous voltage” within the product‟s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. This product was designed and manufactured to meet strict quality and safety standards. There are, however, some installation and operation precautions, which you should be particularly aware of. 1. Read Instructions – All the safety and operating instructions should be read before the appliance is operated. 2. Retain Instructions – The safety and operating instructions should be retained for future reference. 3. Heed Warnings – All warnings on the appliance and in the operating instructions should be adhered to. 4. Follow Instructions – All operating and use instructions should be followed. 5. Water and Moisture – The appliance should not be used near water – for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc. 6.
    [Show full text]
  • Whitepaper: Understanding Ethernet Patch Cords in Modern Networks
    Intelligently Designed Rack and Cable Management UNDERSTANDING ETHERNET PATCH CORDS IN MODERN NETWORKS Louis Chompff - Founder & Managing Director © 2020 AnD Cable Products Inc. andcable.com UUNDERSTANDINGNDERSTANDING EETHERNETTHERNET PPATCHATCH CCORDSORDS IN MMODERNODERN NENETWORKSTWORKS Copyright ©AnD Cable Products Inc. 2020. All Table of Contents rights reserved. This whitepaper and its content is 1. Ethernet Patch Cords and RJ-45 Connectors 3 copyright of AnD Cable Products Inc. Any redistribution or reproduction of part or all of the contents in any form is 2. Ethernet Patch Cords and UTP Cabling 4 prohibited other than the following: • you may print or locally download for 3. What’s All the Twisting About? 5 your personal and non-commercial use only • you may copy the content to individual 4. Ethernet Applications 7 third parties for their personal use, but only if you acknowledge AnD Cable 5. 568A and 568B Wiring Standards 7 Products Inc. as the source of the material You may not, except with our express written 5.1 Beware of Copper Clad Aluminum 8 permission, distribute or commercially exploit (CCA) Cables the content. Nor may you transmit it or store it in any other website or other form of electronic retrieval system. 6. Which One to Use? 10 7. Straight-Through and Crossover Cables 10 7.1 Data Communications Equipment (DCE) 12 and Data Terminal Equipment (DTE) 8. Glossary 14 About the Author 15 Celebrating over 30 years’ experience in the Manufacture and Supply of Cable Management and Rack Management Products andcable.com UUNDERSTANDINGNDERSTANDING EETHERNETTHERNET PPATCHATCH CCORDSORDS IINN MMODERNODERN NNETWORKSETWORKS Ethernet patch cables have modular characteristics and some important differences that can limit their interchangeability.
    [Show full text]
  • Adslme1 User Guide.Qxd
    Instant BroadbandTM Series ADSL Ethernet Modem Use this guide to install the following: Model No.: ADSLME1 User Guide COPYRIGHT & TRADEMARKS Copyright© 2001 Linksys, All Rights Reserved. Instant Broadband is a registered trade- mark of Linksys. Microsoft, Windows, and the Windows logo are registered trademarks of Microsoft Corporation. All other trademarks and brand names are the property of their respective proprietors. LIMITED WARRANTY Linksys guarantees that every Instant Broadband ADSL Ethernet Modem is free from physical defects in material and workmanship for one year from the date of purchase, when used within the limits set forth in the Specification section of this User Guide. If these products prove defective during this warranty period, call Linksys Customer Support in order to obtain a Return Authorization Number. BE SURE TO HAVE YOUR PROOF OF PURCHASE AND A BARCODE FROM THE PRODUCT'S PACKAGING ON HAND WHEN CALLING. RETURN REQUESTS CANNOT BE PROCESSED WITHOUT PROOF OF PURCHASE. When returning a product, mark the Return Authorization Number clearly on the outside of the package and include your original proof of pur- chase. All customers located outside of the United States of America and Canada shall be held responsible for shipping and handling charges. IN NO EVENT SHALL LINKSYS’ LIABILITY EXCEED THE PRICE PAID FOR THE PROD- UCT FROM DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAM- AGES RESULTING FROM THE USE OF THE PRODUCT, ITS ACCOMPANYING SOFT- WARE, OR ITS DOCUMENTATION. LINKSYS DOES NOT OFFER REFUNDS FOR ANY PRODUCT. Linksys makes no warranty or representation, expressed, implied, or statuto- ry, with respect to its products or the contents or use of this documentation and all accompanying software, and specifically disclaims its quality, performance, mer- chantability, or fitness for any particular purpose.
    [Show full text]
  • Technical Information Handbook Wire and Cable
    Technical Information Handbook Wire and Cable Fifth Edition Copyright © 2018 Trademarks and Reference Information The following registered trademarks appear in this handbook: Information in this handbook has been drawn from many Alumel® is a registered trademark of Concept Alloys, LLC publications of the leading wire and cable companies in the industry and authoritative sources in their latest available Chromel® is a registered trademark of Concept Alloys, LLC editions. Some of these include: Copperweld® is a registered trademark of Copperweld Steel Company CSA® is a registered trademark of the Canadian Standards Association • American Society for Testing and Materials (ASTM) CCW® is a registered trademark of General Cable Corporation • Canadian Standards Association (CSA) ® DataTwist is a registered trademark of Belden • Institute of Electrical and Electronics Engineers (IEEE) Duofoil® is a registered trademark of Belden Flamarrest® is a registered trademark of Belden • Insulated Cable Engineers Association (ICEA) Halar® is a registered trademark of Solvay Solexis • International Electrotechnical Commission (IEC) Hypalon® is a registered trademark of E. I. DuPont de Nemours & Company • National Electrical Manufacturers Association (NEMA) Hypot® is a registered trademark of Associated Research, Inc. • National Fire Protection Association (NFPA) IBM® is a registered trademark of International Business Machines Corporation Kapton® is a registered trademark of E. I. DuPont de Nemours & Company • Naval Ship Engineering Center (NAVSEC) Kevlar® is a registered trademark of E. I. DuPont de Nemours & Company • Telecommunications Industry Association (TIA) ® K FIBER is a registered trademark of General Cable Corporation • Underwriters Laboratories (UL). Kynar® is a registered trademark of Arkema, Inc. Loc-Trac® is a registered trademark of Alpha Wire Note: National Electrical Code (NEC) is a registered trademark of the National Fire Protection Association, Quincy, MA.
    [Show full text]
  • What Is a Registered Jack? Getting RJ Connector Names Confused
    RJ-45 RJ-45 is one of the more popular standardconnector types used with unshielded, twisted pair network cables. The RJ-45 connector type is commonly used with Ethernet cables and includes eight pins that interface with the cable wires electrically and is sometimes used with shielding cabling. The pin-outs of the connector are defined to provide cable manufacturers the location that wires need to be placed when attaching the cable to a RJ-45 connector type. There are a number of other connector types on the market such as RJ-11used for telephone cable connections, but are more narrowly shaped. What is a Registered Jack? The RJ designation for the RJ-45 cable stands for “registered jack” and indicates that the connection is defined in the international standard for physical network interfaces. The standard defines both the wiring pattern and connecting jack construction for those intended for use in data services or telecommunications equipment. The interfaces defined in the RJ standard include RJ-11, RJ-14, RJ-21, RJ-45, and the RJ-48 connector types. Of the defined connectors, the RJ standard primarily makes use of the 50 pin miniature ribbon and modular connector types depending on the specific RJ type that is defined. Getting RJ Connector Names Confused Since the RJ standard defines both the physical geometry and the required wiring pattern, an inspection of just the connector type will not necessarily indicate the type of wiring pattern used in the cable. This is due to the fact that the same connector can be used for different wiring patterns! As a result, there has been a fair amount of confusion by consumers on what type of cable standard is being used depending on the application.
    [Show full text]
  • Introduction to Wired Media Fundamentals of Networking
    Fundamentals of Networking Introduction to Wired Media Kuldeep Sonar 1 STP (Shielded Twisted Pair) • This cable has a conductive braided or foil casing for each pair and theoretically offers very good protection from interference and crosstalk. It was commonly used for token ring networks. • Higher cost due to greater complexity for the cabling and connectors • Larger size and less flexibility of the cabling • Longer installation time Kuldeep Sonar 2 UTP (Unshielded Twisted Pair) • UTP is the most commonly used type of networking cable. UTP cables are often called "Ethernet Cables" after Ethernet, the most common data networking standard that utilizes UTP cables, although not the most reliable. • In contrast to STP cabling, UTP cable is not surrounded by any shielding. It is the primary wire type for telephone usage and is very common for computer networking, especially in patch cables or temporary network connections due to the high flexibility of the cables. • Total 7 Categories Kuldeep Sonar 3 CAT3 • Cable designed to reliably carry data up to 10 Mbit/s,. • Category 3 was a popular cabling format among computer network administrators in the early 1990s. CAT5 • Ethernet capability of 100 Mbit/s • Typically has three twists per inch of each twisted pair of 24 gauge copper wires within the cable. • The twisting of the cable reduces electrical interference and crosstalk. CAT6 • The cable contains four twisted copper wire pairs, just like earlier copper cable standards • Each twisted pair is made up of slightly larger 23 gauge copper wire as opposed to Cat 5's 24 gauge • The distance without losing data is 220 m.
    [Show full text]
  • STANDARDS and INFORMATION DOCUMENTS Call for Comment on AES Standard on Interconnections — Application of RJ45-Type Connectors
    DRAFT FOR COMMENT ONLY - DRAFT FOR COMMENT ONLY DRAFT AES72-xxxx STANDARDS AND INFORMATION DOCUMENTS Call for comment on DRAFT AES72-xxxx AES standard on interconnections — Application of RJ45-type connectors and quad twisted pair cable for audio interconnections This document was developed by a writing group of the Audio Engineering Society Standards Committee (AESSC) and has been prepared for comment according to AES policies and procedures. It has been brought to the attention of International Electrotechnical Commission Technical Committee 100. Existing international standards relating to the subject of this document were used and referenced throughout its development. Address comments by E-mail to [email protected], or by mail to the AESSC Secretariat, Audio Engineering Society, 551 Fifth Ave., New York NY 10176. Only comments so addressed will be considered. E-mail is preferred. Comments that suggest changes must include proposed wording. Comments shall be restricted to this document only. Send comments to other documents separately. Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to provide supporting documentation. This document will be approved by the AES after any adverse comment received within six weeks of the publication of this call on http://www.aes.org/standards/comments/, 2019-02-15, has been resolved. Any person receiving this call first through the JAES distribution may inform the Secretariat immediately of an intention to comment within a month of this distribution. Because this document is a draft and is subject to change, no portion of it shall be quoted in any publication without the written permission of the AES, and all published references to it must include a prominent warning that the draft will be changed and must not be used as a standard.
    [Show full text]
  • TELEBIT® When Connectivity Counts
    Modem Reference Manual for the Telebit T3000 and WorldBlazer Family of Products 90238-01 ., ' '1IJ TELEBIT® When connectivity counts. Modem Reference Manual for the Telebit T3000 and WorldBlazer Family of Products 90238-01 How to Use This Manual About This Manual This manual is a reference guide for using any of the Telebit T3000 and WorldBlazer modems. It is designed for both new and experienced modem users. To help you install and configure the modem, refer to the User's Guide for your particular modem. It is a separate booklet provided with your modem. If you have special requirements or experience any problems while using. your User's Guide, refer to this manual for additional information. Note: Read your User's Guide before reading this reference manual. Whether you are a first-time or experienced user, install your modem using the instructions in your User's Guide. This manual contains six chapters and four appendices: • Chapter 1, Introduction, describes the main features of the modem. • Chapter 2, Modem Operation and Special Features, describes command mode operations, flow control, RS-232 control signal interpretations, error control, data compression, protocol support, and synchronous support. • Chapter 3, AT Command Descriptions, describes the commands and explains the possible parameters, the range of parameters, and the default settings. 90238-01 How to Use This Manual • Chapter 4, S Register Descriptions, describes the registers used to operate the modem and explains the possible parameters, the range of parameters, and the default settings. • Chapter 5, Troubleshooting, describes the diagnostic tests performed by the modem after it is powered up.
    [Show full text]
  • Wheatstone Corporation Technical Documentation
    Wheatstone Corporation Technical Documentation The Role of Wiring Integrity on WheatNet-IP Network Reliability A Review of Gigabit Ethernet Network Cabling Requirements and Common Installation Practices 600 Industrial Drive New Bern, NC 28562 252.638.7000 www.wheatstone.com Paul Picard – January 2010 v 1.0 Introduction Whether you are building a brand new gigabit network for audio transport, expanding a simple fast Ethernet network, or just making some patch cables for your current network the same general rules apply. By building and maintaining your network the “right way” you ensure the long term reliability of this fundamental but critical part of your IP based audio distribution system. This document will explain the process of selecting the components and building the cabling infrastructure that will be the backbone of your high speed audio data network. Network Speed Any discussion of building a wiring plant for an audio over IP system should start with a clear understanding of what will be connected to the system now and in the foreseeable future. The WheatNet IP Blade hardware was designed to utilize the 1000 Base T Gigabit Ethernet standard exclusively as the transport mechanism for all audio i/o and mix engine traffic. Certain mixing and routing control devices as well as general purpose PC’s on the network continue to use Fast Ethernet 100BASE–TX connectivity. With this in mind, the wiring plant we will discuss must support gigabit connectivity from end to end. Ethernet Wiring Standards While it is true that you could install a basic Ethernet network without knowing anything about standards – short of the RJ45 wiring scheme – installers of Ethernet networks for professional use in commercial spaces which are subject to official inspector review will find the standards information invaluable.
    [Show full text]