Professional Weather Center 01036 Instructions
Total Page:16
File Type:pdf, Size:1020Kb
Instruction Manual Professional Weather Center model 01036 CONTENTS Unpacking Instructions ........... 2 5-in-1 Sensor Installation ........12 Package Contents .................. 2 AcuRite Connect ...................13 Product Registration ............... 2 Weather Underground ..........13 Features & Benefits: 5-in-1 ....... 3 Using the Weather Center .....14 Features: Display ................... 4 Weather Ticker .....................15 Back of Display ...................... 6 Programmable Alarms ...........17 Setup .................................... 7 Troubleshooting ....................19 5-in-1 Sensor Setup ................ 7 Care & Maintenance ............ 22 Display Setup ........................ 8 Calibration .......................... 22 Set the Time & Date ............... 9 Specifications ........................24 Measurement Units ...............10 FCC Information ...................24 Set Language .......................10 Customer Support ................ 25 Placement Guidelines ............11 Warranty............................. 25 Questions? Contact Customer Support at (844) 228-5465 or visit www.AcuRite.com. SAVE THIS MANUAL FOR FUTURE REFERENCE. Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference. Unpacking Instructions Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel off to remove. Package Contents 1. Display with tabletop stand 2. 5-in-1 sensor 3. Sensor mounting bracket 4. Mounting hardware 5. Power adapter 6. USB cable 7. Instruction Manual PRODUCT MUST BE REGISTERED IMPORTANT TO RECEIVE WARRANTY SERVICE PRODUCT REGISTRATION Register online to receive 1 year warranty protection www.AcuRite.com ►Register a Product 2 Features & Benefits 7 1 2 9 11 3 4 5 8 6 10 5-in-1 SENSOR 1. Rainfall Collector Funnel 5. Temperature & Humidity Sensors (internal) 2. Solar Cell Panel Converts sunlight into power to run 6. Mounting Point internal aspirating fan. 7. Wind Speed Anemometer Internal Aspirating Fan 8. Wind Direction Vane (not shown) Draws ambient air into 9. Mounting Bracket sensor to reduce solar radiation 10. Mounting Hardware heating, resulting in more accurate Includes anchors & screws. temperature measurement. Qty Diameter Length 3. A-B-C Switch 4 #4 1” ID code that must match display’s 2 #6 ½” A-B-C switch to ensure units 11. Debris Filter synchronize. Pre-installed to prevent debris from 4. Battery Compartment entering the rain gauge. 3 Features & Benefits Display 1 2 3 4 4 41 5 6 40 39 7 8 38 9 37 36 10 35 11 12 34 13 33 14 32 15 16 17 31 18 30 19 29 28 20 26 27 26 23 25 24 23 22 21 4 1. Current Wind Direction 22. Activate Weather Ticker Message 2. Touch Activated Backlight 23. “▲“/”▼“ to Select Category Momentary during battery power, (#17) & Adjust Settings always on/off for power adapter. 24. Weather Ticker Manual Cycle 3. Current Wind Speed Press to advance through messages. 4. Previous 2 Wind Directions 25. “ “ Button 5. Current Outdoor Temperature for setup preferences. Arrow icon indicates direction 26. Alarm On/Off Button temperature is trending. Activate alarm; press and hold to 6. Outdoor Temperature Alarm On adjust alarm values. Indicator 27. Deactivate Weather Ticker 7. Current Outdoor Humidity Message Arrow icon indicates direction 28. Indicates Deactivated Weather humidity is trending. Ticker Message 8. Outdoor Humidity Alarm On During ticker customization mode. Indicator 29. Indicates Active Weather Ticker 9. Current Rainfall Message Accumulates data during rainfall. During ticker customization mode. 10. Rainfall Alarm On Indicator 30. Programmable Alarm Settings 11. 12 to 24 Hour Weather Forecast 31. Alarm On/Off Indicator Self-Calibrating Forecasting pulls for Selectable Category (#17). data from your 5-in-1 sensor to 32. Low Battery Indicator generate your personal forecast. 33. 5-in-1 Sensor Signal Strength 12. All-Time Rainfall 34. Learning Mode Icon 13. Current Month Total Rainfall Disappears after weather forecast 14. Date self-calibration is complete. 15. Clock 35. Weather Select Button Press to change the Weather Select 16. Display Low Battery Indicator category data being displayed. 17. Selectable Category 36. Current Barometric Pressure 18. Record Highs Arrow icon indicates direction Shown for current category selected pressure is trending. on the display (#17). 37. Weather Select (top to bottom) 19. Record Lows Heat index, dew point, wind chill, Shown for current category selected indoor temperature / humidity, on the display (#17). rainfall rate (rain per hour). 20. Weather Ticker™ 38. Storm Alert Alarm On Indicator 21. All-Time Records Button 39. Average Wind Speed Press for all-time low and date of all speeds from past 2 minutes. recorded for current category 40. Wind Speed Alarm On Indicator selected on display (#17). Press twice for all-time high and date recorded. 41. Peak Wind Speed Highest speed from past 60 minutes. 5 Back of Display 1 2 3 4 6 7 8 9 5 10 11 BACK OF DISPLAY 7. Clear Today Clears data recorded since 1. Plug-in for Power Adapter 12:00 am. 2. Plug-in for USB Cable 8. Clear All 3. Integrated Hang Hole Clears all recorded data without For easy wall mounting. having to reset time and date. Note: USB mode will be reset to 4. MAC ADDRESS Mode 2 (Default). 12 digit unique ID required for online connectivity functions. 9. Reset Full reset to factory defaults. 5. Backup Battery Compartment 10. Power Adapter 6. A-B-C Switch ID code that must match 5-in-1 11. USB Cable for PC Connection sensor’s A-B-C switch to ensure 12. Battery Compartment Cover units synchronize. (not shown) 6 SETUP 5-in-1 Sensor Setup 1 Set the A-B-C Switch cause alkaline batteries to function improperly. Use lithium batteries in Locate the A-B-C switch inside the the 5-in-1 sensor for temperatures battery compartment. Set the A-B-C below -4ºF / -20ºC. switch to A, B or C. You must select the same letter choices for both the 1. Slide off the battery sensor and the display in order for compartment cover. the units to synchronize. 2. Insert 4 x AA batteries into the battery compartment, as 2 Install or Replace Batteries shown. Follow the polarity (+/-) diagram in the battery Batteries MUST be installed for compartment. this product to operate. AcuRite recommends high quality alkaline 3. Replace the battery cover. or lithium batteries for the best product performance. Heavy duty 3 Remove Rain Gauge Stabilizer or rechargeable batteries are not recommended. Locate and remove the rain gauge stabilizer (plastic tab) taped into The 5-in-1 sensor requires lithium the bottom of the sensor. The rain batteries in low temperature gauge will not function until this is conditions. Cold temperatures can removed. A B C 1 A-B-C Switch Set to match display 3 Rain Gauge Stabilizer Remove and discard 2 Install Batteries 4 AA Batteries 7 Display Setup 1 Set the A-B-C Switch 3 Write Down the MAC ADDRESS The A-B-C switch is located inside 12 digit unique ID needed for the battery compartment. It can online connectivity functions. be set to A, B or C. However, you must select the same letter 4 Install or Replace Backup choices for both the sensor and Batteries (optional) the display in order for the units Insert 6 x AA alkaline batteries to synchronize. into the battery compartment, as shown. Follow the polarity 2 Plug Power Adapter into (+/-) diagram in the battery Electric Outlet compartment. 3 Write Down MAC ADDRESS 4 Install Backup 12 digit number Batteries 1 A-B-C Switch 6 AA Batteries set to match (optional) sensor A B C 2 Plug in Power Adapter IMPORTANT: Batteries are a backup power source to preserve records in the event of a power outage. Power adapter is the recommended primary power source to enjoy the full functionality of this product. PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS. BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals. 8 Set the Time & Date The clock and calendar are utilized to time stamp history records and other data, so it is important to set the time and date soon after you power on the display. Set the Time 1. Press the “▲“ or “▼“ buttons until “SET CLOCK?” is displayed on the Selectable Category part of the display. 2. Press the “ ” button to set the clock. 3. Press the “▲“ or “▼“ buttons to adjust the hour. Note the “AM” and “PM” indicators. 4. Press the “ ” button to confirm hour selection. 5. Press the “▲“ or “▼“ buttons to adjust minutes. 6. Press the “ ” button to confirm minute selection. The clock is now set. Note: The “ ” stays in Set the Date Selectable Categories, 1. Press the “▲“ or “▼“ buttons until even after setup. “SET DATE?” is displayed on the Selectable Category part of the display. 2. Press the “ ” button to set the date. 3. Press the “▲“ or “▼“ buttons to adjust the month. 4. Press the “ ” button to confirm month selection. 5. Press the “▲“ or “▼“ buttons to adjust the day. 6. Press the “ ” button to confirm day selection. 7. Press the “▲“ or “▼“ buttons to adjust the year. 8. Press the “ ” button to confirm year selection. The date is now set. 9 Select Measurement Units To select between standard units (mph, ºF, etc.) or metric units (kph, ºC, etc.): 1.