XSCF User's Guide
Total Page:16
File Type:pdf, Size:1020Kb
eXtended System Control Facility User's Guide - System Monitor and Control Facility (eXtended System Control Facility: XSCF) User's Guide - C120-E184-02EN All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003 All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003 Contents Preface iv About This Manual iv Summary of Changes in Second Edition vi Summary of Changes in First Edition Revision1 viii About UNIX Commands viii About Notation in This Manual viii Shell Prompts viii About model name ix Caution ix Chapter1 Overview of XSCF 1-1 XSCF Features 1-2 Types of Connection to XSCF 1-5 XSCF User Interfaces 1-7 XSCF Monitoring and Linkage to Other Functions 1-9 Time synchronization 1-12 Chapter2 Setting Up XSCF 2-1 XSCF Setup Flow 2-2 Specifying the XSCF Settings 2-4 Network Configuration 2-4 User Account Administration 2-7 Console Administration 2-11 XSCF Web Administration 2-14 SNMP Administration 2-18 Mail Administration 2-22 Chapter 3 Connecting XSCF or Server 3-1 Connecting Terminals to XSCF 3-2 Types of XSCF Connection 3-7 Connecting XSCF to PC and UPC 3-9 Connecting of RCI 3-10 Basic configration 3-10 Cluster Configration 3-11 Method of configration of RCI 3-12 How to change the input-output destination of OS console to tty-a 3-14 Chapter4 How to Use the Remote Panels 4-1 Overview of the Remote Panels 4-2 How to Use the Remote Panels 4-4 LED Indicators on the Remote Panels 4-7 Differences from the Operating Panels 4-9 Chapter5 How to Use the XSCF Web Function 5-1 Overview of the XSCF Web Function 5-2 Starting the XSCF Web Function 5-3 Logging In to or Out from XSCF 5-4 XSCF Web Function Pages 5-5 i All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003 Chapter6 How to Use the XSCF Command Shell 6-1 Overview of XSCF Command Shell 6-2 Login to XSCF User Account 6-4 Server Status and Control Commands 6-6 XSCF Log View Command 6-13 XSCF Server Configuration Information Command 6-21 Other XSCF Commands 6-25 XSCF Shell Error Messages 6-28 Chapter7 XSCF SNMP Agent Function 7-1 Summary of XSCF SNMP Agent Function 7-2 About MIB 7-3 About Traps 7-4 How to Set up the XSCF SNMP Agent Function 7-5 Introduce Extended MIB of XSCF to SNMP Manager 7-6 Installation case to WebSysAdmin 7-6 Installation case to SystemWalker 7-8 Chapter 8 XSCF Mail Function 8-1 Overview of XSCF Mail Function 8-2 Reporting Parts Faults 8-4 Reporting an Authentication Failure 8-5 Setting up the XSCF Mail Function 8-6 Contents of Parts Fault Notification 8-7 Contents of Authentication Failure Notification 8-9 Contents of Test Mail Notification 8-10 Contents of Suspension Mail Notification 8-11 Appendix 9 XSCF Firmware Upgrade and Dump 9-1 Upgrading the XSCF Firmware 9-2 How to Get XSCF Dump Information and Collect Logs 9-4 Appendix A Warning Messages A-1 Message Types A-2 Messages in Each Function A-4 Appendix B XSCF Log Information B-1 XSCF Error Log List and Actions B-2 XSCF Power Log List B-51 XSCF Event Logs List B-57 XSCF Error Code Table B-64 Appendix C XSCF MIB C-1 MIB Object ID C-2 Standard MIB C-3 Fujitsu Extended MIB C-7 TRAP C-9 Appendix D Troubleshooting D-1 Troubleshooting XSCF D-2 Troubleshooting the Server While XSCF Is Being Used D-5 ii All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003 Glossary W-1 iii All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003 Preface About This Manual [Purpose] This manual describes the system monitor and control facility (eXtended System Control Facility, or XSCF, hereafter) used to control, monitor, operate, and service PRIMEPOWER series servers and their systems. XSCF may also be referred to as the System Control Facility (SCF). [Audience] This manual is intended for users, specifically system management/maintenance administrators. [Organization] This manual consists of the following chapters: ● Overview ● Setting up XSCF ● Connecting XSCF or Server ● How to use the remote panels ● How to use the XSCF Web function ● How to use the XSCF command shell ● XSCF SNMP agent function ● XSCF mail function ● XSCF firmware and dump ● Warning Messages ● XSCF Log Information ● XSCF MIB ● Troubleshooting ● Glossary [Related Manuals] Refer to the following manuals as necessary: ● PRIMEPOWER250/450 User's Manual ● Machine Administration Guide ● Enhanced Support Facility User's Guide ● REMCS Agent Operator's Guide [About Registered Trademarks] Sun, Sun Microsystems, the Sun logo, Solaris(TM) Operating Environment (Solaris OE, hereafter), and all other Solaris OE-related trademarks and logos are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and/or other countries, and are used under license. Microsoft is a registered trademark of Microsoft Corporation in the United States and/or other countries. Netscape and Netscape Navigator are trademarks or registered trademarks of Netscape Communications Corporation in the United States and/or other countries. Other company and product names are trademarks or registered trademarks of their respective owners. iv All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003 [Acknowledgement] The TCP/IP-based communication functions of the LAN-communication administration functions described in this manual were developed by Fujitsu Ltd. according to BSD NETWORKING SOFTWARE RELEASE 1, 4.4 BSD Lite 2, and their documentation under license from the University of California at Los Angels (UCLA). We express our gratitude to the Computer Systems Research Group and Electrical Engineering and Computer Science Department at UCLA, Berkeley. Note that Fujitsu Ltd. holds the copyright on the TCP/IP-based communication functions for XSCF and any secondary documentation related to them. Copyright (c) 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994 The Regents of the University of California. All rights reserved XSCF Web Access was developed with the use of Apache and OpenSSL and mod_ssl. We would like to express our gratitude to the Apache Group, OpenSSL Project, Mr. Eric Young and mod_ssl project. This product includes software developed by the Apache Group for use in the Apache HTTP server project (http://www.apache.org/). This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit. (http://www.openssl.org/) This product includes cryptgraphic software written by Eric Young ([email protected]). This product includes software developed by Ralf S. Engelschall <[email protected]> for use in the mod_ssl project (http://www.modssl.org/). April 2003 April 2003, Second Edition C120-E184-02EN [Important] Do not copy the whole or any part of this manual without permission. This manual is subject to change without prior notice. Electrical form of this manual is installed under following path: The revised edition for this manual can be referred to from the following path on the server (or HCP-CD*): /opt/FJSVhcp/manual *HCP (: An abbreviation of Hardware Control Program. HCP is a control program of hardware that configures a computing system.) When you face different description written on the online manual from what written on paper manual, please follow the online manual. Path: /PWPL0/MANUAL The MIB new file can be refferred to from the following path in the HCP-CD. /PWPL0/MIB v All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003 Summary of Changes in Second Edition The current, second edition of this manual differs from previous edition with Revision1 principally by containing the menus of Machine Administration function. The second edition contains minor clarifications and corrections and also the following significant changes relative to the previous edition with Revision1. Preface: ― In "Caution", a description is changed that we do not support "The DNS function in case of using XSCF Mail function". ― In "Caution", a description of "XSCF SNMP Agent function" is deleted. Chapter 2, "Setting Up XSCF": ― The menu name of "Basic configuration" and the described section is changed to two new menus, "Network Configuration" and "Console Administration". The contents are as follows. ‐ In the menu of "Basic configuration", each options, "Basic network configuration" and "Host name configuration" are moved to "Network Configuration" menu. The section of "Network Configuration" is added. ‐ In the menu of "Basic configuration", each options, "Select Standard console", "Access control of console port", and "Auto-disconnect administration" are moved to "Console Administration" menu. The section of "Console Administration" is added. ‐ The section of "Basic configuration" is deleted. ― Option and description of "Name server configuration" in all menu is deleted. (In Chapter8 and AppendixD, descriptions of "DNS function" or "Name server configuration" are deleted at the same time.) ― In "Console Administration", a description of "Caution" is added in "Access Control of Read-only Console"'s Remarks of Table 2-3. Chapter 3, "Connecting XSCF or Server": ― In "Connecting Terrminals to XSCF", descriptions are added as follows: ‐ A description of "Read-only console" is added in Table3-1. ‐ A description of "break" is added. ― In "How to Configure RCI", the definition of "Automatic power-on prohibition mode after the forced power off " in the mode "mode of power supply for remote control " is added. ― "How to change the input-output destination of OS console to tty-a" is added. Chapter 4, "How to Use the Remote Panel": In "Before using the remote Panel", a description of "Basic settings" is changed to "Network settings" and "Console settings". Chapter 5, "How to Use the XSCF Web Function ": ― In "Table 5-1 XSCF Web function pages", a description of "Authentication" page is added. ― In "Function to be enabled on the browser", Items are corrected as follows: ‐ A description of option setting on Microsoft(R) Internet Eplorer is added.