Sun Firetm 12K/15K Just the Facts" Chapter 1 - "Sun Fire 12K & 15K Server Positioning"

Total Page:16

File Type:pdf, Size:1020Kb

Sun Firetm 12K/15K Just the Facts Sun FireTM 12K System & Sun FireTM 15K System JUST THE FACTS Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 U.S.A. 650-960-1300 November 12th 2002 Sun Proprietary – Internal Use Only Copyrights © 2002 Sun Microsystems, Inc., 901 San Antonio Road • Palo Alto, CA 94303 USA. All Rights Reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party software, including font technology, is copyrighted and licensed from Sun suppliers. Sun, Sun Microsystems, the Sun logo, Sun Fire, UltraSPARC, Solaris, Sun Fireplane, Sun GigabitEthernet, Sun HIPPI/P1.0, Sun Enterprise Systems Interface, Sun Management Center 3.0, Sun StorEdge, Sun StorEdge Volume Manager, SunATM, Java, Sun HPC ClusterTools,ONC/NFS, SunNet, Solstice Site Manager, Solstice Domain Manager, Solstice DiskSuite, Solstice Backup, Sun StorEdge, Sun Quad FastEthernet, SunSolve, SunVIP, Sun Enterprise, ServerStart, SunReady, Sun Professional Services, SunSpectrum, StorEdge S1, and SunSpectrum Platinum are trademarks or registered trademarks of Sun Microsystems, Inc., in the United States and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc., in the United States and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. UNIX is a registered trademark in the United States and other countries, exclusively licensed through X/Open Company, Ltd. All other trademarks are trademarks of their respective owners. JUST THE FACTS Sun Proprietary - Internal Use Only November 12th 2002 Table of Contents - "Sun FireTM 12K/15K Just The Facts" Chapter 1 - "Sun Fire 12K & 15K Server Positioning"........................................................... Product Overview: Sun Fire 12K/15K Servers...................................................................1 Target Markets and Users for the Sun fire 12K and 15K Systems...................................2 Technical Computing Customers.........................................................................................3 Performance..........................................................................................................................4 Markets and Applications.....................................................................................................7 Sun Fire 12K One Minute Summary....................................................................................9 A few Sun Fire 12K Q&As..................................................................................................10 Chapter 2 - "Selling Highlights"................................................................................................ Channels and Support..........................................................................................................1 Performance - Key Selling Factors......................................................................................1 Chapter 3 - "Reliability, Availability, Serviceability Features (RAS)"................................. Definitions..............................................................................................................................1 - Reliability - Rate of failure of a system - Availability - Quality of being accessible and ready for use - Serviceability - Maintenance and Repair Effectiveness SPARC processor error protection......................................................................................3 Data cache error protection..................................................................................................3 System interface error protection.........................................................................................4 Address interconnect error protection.................................................................................4 Data interconnect error isolation..........................................................................................4 Console bus error protection................................................................................................4 Redundant Components.......................................................................................................4 Redundant CPU/Memory boards.........................................................................................5 Redundant expander boards................................................................................................5 Redundant hsPCI assemblies..............................................................................................5 Redundant PCI cards...........................................................................................................5 Redundant MaxCPU boards................................................................................................5 Redundant system controllers.............................................................................................6 Redundant system clocks....................................................................................................6 Redundant power..................................................................................................................6 Redundant fans.....................................................................................................................7 Reconfigurable Logic Centerplane (Fireplane)...................................................................8 Automatic System Recovery................................................................................................9 System Controller..................................................................................................................9 Console Bus........................................................................................................................10 Environmental Monitoring...................................................................................................10 Temperature........................................................................................................................10 Power Subsystem...............................................................................................................10 Field Replaceable Unit Identification.................................................................................11 Concurrent Serviceability...................................................................................................11 Dynamci Reconfiguration of System Boards....................................................................12 System controller removal and replacement....................................................................12 Remote Service...................................................................................................................13 RAS features.......................................................................................................................13 Chapter 4 - "Enabling Technology".......................................................................................... Technology............................................................................................................................1 JUST THE FACTS Sun Proprietary - Internal Use Only November 12th 2002 Chapter 5 - "System Architecture"............................................................................................ Introduction............................................................................................................................1 Logic Centerplane.................................................................................................................1 Address Crossbar.................................................................................................................2 Response Crossbar..............................................................................................................2 Data Crossbar.......................................................................................................................2 Address Crossbar.................................................................................................................2 Boardsets (Expanders).........................................................................................................2 Expander board.....................................................................................................................3 Slot-0 (Top) boards (Uniboards)..........................................................................................3 Slot-1 (Bottom) boards..........................................................................................................4 Control Board set ................................................................................................................4 Peripherals.............................................................................................................................6 System Interconnect (Fireplane)..........................................................................................6 Centerplane Interconnect Levels.........................................................................................8 Interconnect Performance....................................................................................................9
Recommended publications
  • Gigaplane-XB: Extending the Ultra Enterprise Family
    Gigaplane-XB: Extending the Ultra Enterprise Family Alan Charlesworth ([email protected]), Andy Phelps, Ricki Williams, Gary Gilbert Sun Microsystems, Inc. Abstract The Gigaplane-XB interconnect of the Starfire system extends the range of Sun’s Ultra Enterprise SMP server family by 4x. It uses multi-level address and data routers to provide 167 million global snoops per second, and 10,667 MBps of uniform-memory-access band- width. The use of point-to-point routers allows the system to be dynamically reconfigured into multiple hardware-protected operating system domains, with hot-swappable boards. Comparisons are made with the bus-based technology of the smaller family members. 1. Introduction Table 1 compares the memory-port architectures of cur- rent microprocessors. A combination of a 16-byte wide When a new processor debuts, we hear mostly about its data path, a 100 MHz system clock, and separate address SPECint95 and SPECfp95 performance. It is probably and data paths has made Sun’s Ultra Port Architecture more important to know how well a processor’s power is (UPA) among the highest-bandwidth memory ports. The balanced its memory bandwidth and latency. From a sys- UPA is used across all Sun’s UltraSPARC systems: from tem designer’s perspective, the main reason to have an desktop workstations to the 64-processor Starfire instruction set architecture is to get the opportunity to (UltraEnterprise/High Performance Computing 10000) engineer into the processor chip a good interconnect server. architecture. Table 1. Memory-port characteristics. Max Data Separate Data Peak data Instruction set Interconnect Current CPU Port width address duty bandwidth architecture architecture model MHz (bytes) and data? factor (MBps) SPARC UPA [9] UltraSPARC-II 100 16 Yes 100% 1,600 Alpha See [3] 21164 88 16 Yes 100% 1,408 Mips Avalanche [18] R10000 100 8 No 84% 840 PA-RISC Runway [1] PA-8000 120 8 No 80% 768 PowerPC See [2] PPC 604 67 8 Yes 100% 533 Pentium Pro/II See [5] Pentium Pro/II 67 8 Yes 100% 533 2.
    [Show full text]
  • Ultrasparc Iii
    UltraSparc IIi Kevin Normoyle and the Sabre cats One size doesn’t fit all SPARC chip technology available in three broad product categories: • S-Series (servers, highest performance) • I-Series (price/performance, ease-of-use) • E-Series (lowest cost) Tired: Marginal micro-optimizations Wired: Interfaces and integration. 2 of 26 Desktop/High end embedded system issues • Ease of design-in • Low-cost • Simple motherboard designs • Power • Higher performance graphics interfaces • Low latency to memory and I/O • Upgrades • The J word 3 of 26 UltraSPARC-IIi System Example Module 72-bit DIMM 72-bit DIMM SRAM SRAM UltraSPARC IIi SRAM 75MHz/72-bit XCVRs clocks 100MHz/64-bit 66 or 33 MHz UPA64S 32-bit device 3.3v example: Creator3D graphics APB Advanced PCI Bridge (optional) 33MHz/32-bit 33MHz/32-bit Can use PC-style SUPERIO chips 5v/3.3v 5v/3.3v (boot addressing / INT_ACK features) 4 of 26 Highlights • TI Epic4 GS2, 5-layer CMOS, 2.6v core, 3.3v I/O. • Sun’s Visual Instruction Set - VIS(TM) - 2-D, 3-D graphics, image processing, real-time compression/decompression, video effects - block loads and stores (64-byte blocks) sustain 300 MByte/s to/from main memory, with arbitrary src/dest alignment • Four-way superscalar instruction issue - 6 pipes: 2 integer, 2 fp/graphics, 1 load/store, 1 branch • High bandwidth / Low latency interfaces - Synchronous, external L2 cache, 0.25MB - 2MB - 8-byte (+parity) data bus to L2 cache (1.2 GByte/s sustained) - 8-byte (+ECC) data bus to DRAM XCVRs (400 MByte/s sustained) or UPA64S (800 Mbyte/s sustained) - 4-byte PCI/66 interface.
    [Show full text]
  • Allgemeines Abkürzungsverzeichnis
    Allgemeines Abkürzungsverzeichnis L.
    [Show full text]
  • Sun Fire E2900 Server
    Sun FireTM E2900 Server Just the Facts February 2005 SunWin token 401325 Sun Confidential – Internal Use Only Just The Facts Sun Fire E2900 Server Copyrights ©2005 Sun Microsystems, Inc. All Rights Reserved. Sun, Sun Microsystems, the Sun logo, Sun Fire, Netra, Ultra, UltraComputing, Sun Enterprise, Sun Enterprise Ultra, Starfire, Solaris, Sun WebServer, OpenBoot, Solaris Web Start Wizards, Solstice, Solstice AdminSuite, Solaris Management Console, SEAM, SunScreen, Solstice DiskSuite, Solstice Backup, Sun StorEdge, Sun StorEdge LibMON, Solstice Site Manager, Solstice Domain Manager, Solaris Resource Manager, ShowMe, ShowMe How, SunVTS, Solstice Enterprise Agents, Solstice Enterprise Manager, Java, ShowMe TV, Solstice TMNscript, SunLink, Solstice SunNet Manager, Solstice Cooperative Consoles, Solstice TMNscript Toolkit, Solstice TMNscript Runtime, SunScreen EFS, PGX, PGX32, SunSpectrum, SunSpectrum Platinum, SunSpectrum Gold, SunSpectrum Silver, SunSpectrum Bronze, SunStart, SunVIP, SunSolve, and SunSolve EarlyNotifier are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the United States and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. UNIX is a registered trademark in the United States and other countries, exclusively licensed through X/Open Company, Ltd. All other product or service names mentioned
    [Show full text]
  • Sun Ultratm 5 Workstation Just the Facts
    Sun UltraTM 5 Workstation Just the Facts Copyrights 1999 Sun Microsystems, Inc. All Rights Reserved. Sun, Sun Microsystems, the Sun logo, Ultra, PGX, PGX24, Solaris, Sun Enterprise, SunClient, UltraComputing, Catalyst, SunPCi, OpenWindows, PGX32, VIS, Java, JDK, XGL, XIL, Java 3D, SunVTS, ShowMe, ShowMe TV, SunForum, Java WorkShop, Java Studio, AnswerBook, AnswerBook2, Sun Enterprise SyMON, Solstice, Solstice AutoClient, ShowMe How, SunCD, SunCD 2Plus, Sun StorEdge, SunButtons, SunDials, SunMicrophone, SunFDDI, SunLink, SunHSI, SunATM, SLC, ELC, IPC, IPX, SunSpectrum, JavaStation, SunSpectrum Platinum, SunSpectrum Gold, SunSpectrum Silver, SunSpectrum Bronze, SunVIP, SunSolve, and SunSolve EarlyNotifier are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the United States and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the United States and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. UNIX is a registered trademark in the United States and other countries, exclusively licensed through X/Open Company, Ltd. OpenGL is a registered trademark of Silicon Graphics, Inc. Display PostScript and PostScript are trademarks of Adobe Systems, Incorporated, which may be registered in certain jurisdictions. Netscape is a trademark of Netscape Communications Corporation. DLT is claimed as a trademark of Quantum Corporation in the United States and other countries. Just the Facts May 1999 Positioning The Sun UltraTM 5 Workstation Figure 1. The Ultra 5 workstation The Sun UltraTM 5 workstation is an entry-level workstation based upon the 333- and 360-MHz UltraSPARCTM-IIi processors. The Ultra 5 is Sun’s lowest-priced workstation, designed to meet the needs of price-sensitive and volume-purchase customers in the personal workstation market without sacrificing performance.
    [Show full text]
  • Microsparc-II-Usersm
    Products Rights Notice: Copyright © 1991-2008 Sun Microsystems, Inc. 4150 Network Circle, Santa Clara, California 95054, U.S.A. All Rights Reserved You understand that these materials were not prepared for public release and you assume all risks in using these materials. These risks include, but are not limited to errors, inaccuracies, incompleteness and the possibility that these materials infringe or misappropriate the intellectual property right of others. You agree to assume all such risks. THESE MATERIALS ARE PROVIDED BY THE COPYRIGHT HOLDERS AND OTHER CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS (INCLUDING ANY OF OWNER'S PARTNERS, VENDORS AND LICENSORS) BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THESE MATERIALS, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Sun, Sun Microsystems, the Sun logo, Solaris, OpenSPARC T1, OpenSPARC T2 and UltraSPARC are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and other countries. Products bearing SPARC trademarks are based upon architecture developed by Sun Microsystems, Inc.
    [Show full text]
  • Just the Facts Sunwin Token #333632
    Sun FireTM V480 Server Just the Facts SunWIN token #333632 September 2002 Version 2.7 Notice: This document continues to be restricted to internal usage only because of references to internal web pages. With the removal of these references, selected sections of the document may be provided to customers and/or selling channels as required. Competitive information and relative positioning should always remain as internal documentation only. Copyrights ©2000, 2001 Sun Microsystems, Inc. All Rights Reserved. Sun, Sun Microsystems, the Sun logo, Sun Fire, Ultra, UltraComputing, Sun Enterprise, Sun Enterprise Ultra, Starfire, Solaris, Sun WebServer, OpenBoot, Solaris Web Start Wizards, Solstice, Solstice AdminSuite, Solaris Management Console, Sun Enterprise Authentication Mechanism, SunScreen, Solstice DiskSuite, Sun StorEdge, Sun StorEdge LibMON, Solstice Site Manager, Solstice Domain Manager, Solaris Resource Manager, ShowMe, ShowMe How, SunVTS, Solstice Enterprise Agents, Solstice Enterprise Manager, Java, ShowMe TV, Solstice TMNscript, SunLink, Solstice SunNet Manager, Solstice Cooperative Consoles, Solstice TMNscript Toolkit, Solstice TMNscript Runtime, SunScreen EFS, PGX, PGX32, SunSpectrum, SunSpectrum Platinum, SunSpectrum Gold, SunSpectrum Silver, SunSpectrum Bronze, SunStart, SunVIP, SunSolve, and SunSolve EarlyNotifier are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the United States and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. Microsoft, Netware, Macintosh, Lotus, Oracle, Sybase, Intel, Veritas, Windows, Linux, HP-UX and AIX are the respective trademarks of their owners. UNIX is a registered trademark in the United States and other countries, exclusively licensed through X/Open Company, Ltd.
    [Show full text]
  • Sun Ultratm 2 Workstation Just the Facts
    Sun UltraTM 2 Workstation Just the Facts Copyrights 1999 Sun Microsystems, Inc. All Rights Reserved. Sun, Sun Microsystems, the Sun Logo, Ultra, SunFastEthernet, Sun Enterprise, TurboGX, TurboGXplus, Solaris, VIS, SunATM, SunCD, XIL, XGL, Java, Java 3D, JDK, S24, OpenWindows, Sun StorEdge, SunISDN, SunSwift, SunTRI/S, SunHSI/S, SunFastEthernet, SunFDDI, SunPC, NFS, SunVideo, SunButtons SunDials, UltraServer, IPX, IPC, SLC, ELC, Sun-3, Sun386i, SunSpectrum, SunSpectrum Platinum, SunSpectrum Gold, SunSpectrum Silver, SunSpectrum Bronze, SunVIP, SunSolve, and SunSolve EarlyNotifier are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the United States and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the United States and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. OpenGL is a registered trademark of Silicon Graphics, Inc. UNIX is a registered trademark in the United States and other countries, exclusively licensed through X/Open Company, Ltd. Display PostScript and PostScript are trademarks of Adobe Systems, Incorporated. DLT is claimed as a trademark of Quantum Corporation in the United States and other countries. Just the Facts May 1999 Sun Ultra 2 Workstation Figure 1. The Sun UltraTM 2 workstation Sun Ultra 2 Workstation Scalable Computing Power for the Desktop Sun UltraTM 2 workstations are designed for the technical users who require high performance and multiprocessing (MP) capability. The Sun UltraTM 2 desktop series combines the power of multiprocessing with high-bandwidth networking, high-performance graphics, and exceptional application performance in a compact desktop package. Users of MP-ready and multithreaded applications will benefit greatly from the performance of the Sun Ultra 2 dual-processor capability.
    [Show full text]
  • Sun Enterprise 4500 C/S W
    Sun Enterprise 4500 TPC-C Rev. 5.0 Upgrade from TPC-C Rev 3.5 C/S w/ 20 Front-Ends Report Date: March 19,2001 Upgrade Date: September 25, 2001 Total System Cost TPC-C Throughput Price/Performance Availability Date $1,734,522 67102.63 $25.85 September 14, 2001 tpmC per tpmC Processors Database Manager Operating System Other Software Number of Users SymfoWARE Server Server: 14 * 464 MHz Solaris 8 BEA Tuxedo 6.3 Enterprise Edition for 57200 Clients: 20 * 440 Mhz VLM 3.0 57200 User Connections to 20 Clients using 10Base T Hubs 1000 Users/Segment Sun Enterprise 4500 - 14 464 Mhz 8Mb Cache - 28 GB Memory 20 * Ethernet 100 baseT using 2* 100Base T switches 4 * Sun StorEdge A1000 Array - 12 * 18GB Differential Ultra-SCSI 20 * Sun Ultra 10 Model 440Server Sun StorEdge 18 * Sun StorEdge A5200 Array MultiPack - 22* 18GB FCAL - 6 x 18 GB Configuration Server System Front End Systems Database Nodes: 1 Sun Enterprise E4500 Server 20 * Ultra 10 Model 440 Processors 14* 464 MHz UltraSPARC II 1 * 440MHz UltraSPARC II each Cache memory 32KB (D+I), 8MB external 32KB (D+I), 2MB external, each Main memory 28 GB 1 GB each Disk controllers 3 Dualport FC-AL, 2 Fast/Wide SCSI-2 Disk Drives 450 * 18GB FC-AL (18 * A5200, 4 * 1 * 20GB EIDE A1000), 6 * 18GB SCSI-2 (MultiPack) Total Disk Storage 7560GB 20 GB each 100 BaseT Switches 3 x 24Port None Sun Enterprise 4500 TPC-C Rev. 5.0 Upgrade from TPC-C Rev. 3.5 C/S w/ 20 Front-Ends Report Date: March 24, 2001 Upgrade Date: September 25, 2001 Pricing Summary Description Part Number Source Unit Price Qty Ext Price 3 Yr.
    [Show full text]
  • Microsparc™-Iiep
    Preliminary STP1100BGA December 1997 microSPARC™-IIep DATA SHEET SPARC v8 32-Bit Microprocessor With PCI/DRAM Interfaces DESCRIPTION The microSPARC-IIep 32-bit microprocessor is a highly integrated, high-performance microprocessor. Imple- menting the SPARC Architecture version 8 specification, it is ideally suited for low-cost uniprocessor embedded applications. It is built with leading edge CMOS technology, with the core operating at a low voltage of 3.3V for optimized power consumption. The microSPARC-IIep includes on chip: integer unit (IU), floating-point unit (FPU), large separate instruction and data caches, a 32-entry version 8 reference MMU, programmable DRAM controller, PCI controller, PCI bus interface, a 16-entry IOMMU, flash memory interface support, interrupt controller, 2 timers, internal and boundary scan through JTAG interface, power management and clock generation capabilities. The operating frequencies are 100 MHz. Features Benefits • Integrated 32-bit, 33 MHz PCI expansion bus controller • Connection to industry-standard expansion bus • Integrated 256 MByte DRAM controller • High-bandwidth memory controller to reduce latency • Built-in 16 MByte flash memory controller • Flash memory interface runs real-time operating systems that loads and runs code out of ROM • SPARC high-performance RISC architecture • Compatible with over 10,000 applications and existing development tools • Support for little and big endian byte ordering • Handles with ease PCI devices designed for DOS machines, along with UNIX® applications • 8-window,
    [Show full text]
  • Dynamic Helper Threaded Prefetching on the Sun Ultrasparc® CMP Processor
    Dynamic Helper Threaded Prefetching on the Sun UltraSPARC® CMP Processor Jiwei Lu, Abhinav Das, Wei-Chung Hsu Khoa Nguyen, Santosh G. Abraham Department of Computer Science and Engineering Scalable Systems Group University of Minnesota, Twin Cities Sun Microsystems Inc. {jiwei,adas,hsu}@cs.umn.edu {khoa.nguyen,santosh.abraham}@sun.com Abstract [26], [28], the processor checkpoints the architectural state and continues speculative execution that Data prefetching via helper threading has been prefetches subsequent misses in the shadow of the extensively investigated on Simultaneous Multi- initial triggering missing load. When the initial load Threading (SMT) or Virtual Multi-Threading (VMT) arrives, the processor resumes execution from the architectures. Although reportedly large cache checkpointed state. In software pre-execution (also latency can be hidden by helper threads at runtime, referred to as helper threads or software scouting) [2], most techniques rely on hardware support to reduce [4], [7], [10], [14], [24], [29], [35], a distilled version context switch overhead between the main thread and of the forward slice starting from the missing load is helper thread as well as rely on static profile feedback executed, minimizing the utilization of execution to construct the help thread code. This paper develops resources. Helper threads utilizing run-time a new solution by exploiting helper threaded pre- compilation techniques may also be effectively fetching through dynamic optimization on the latest deployed on processors that do not have the necessary UltraSPARC Chip-Multiprocessing (CMP) processor. hardware support for hardware scouting (such as Our experiments show that by utilizing the otherwise checkpointing and resuming regular execution). idle processor core, a single user-level helper thread Initial research on software helper threads is sufficient to improve the runtime performance of the developed the underlying run-time compiler main thread without triggering multiple thread slices.
    [Show full text]
  • SPARC Assembly Language Reference Manual
    SPARC Assembly Language Reference Manual 2550 Garcia Avenue Mountain View, CA 94043 U.S.A. A Sun Microsystems, Inc. Business 1995 Sun Microsystems, Inc. 2550 Garcia Avenue, Mountain View, California 94043-1100 U.S.A. All rights reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution and decompilation. No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Portions of this product may be derived from the UNIX® system, licensed from UNIX Systems Laboratories, Inc., a wholly owned subsidiary of Novell, Inc., and from the Berkeley 4.3 BSD system, licensed from the University of California. Third-party software, including font technology in this product, is protected by copyright and licensed from Sun’s Suppliers. RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 and FAR 52.227-19. The product described in this manual may be protected by one or more U.S. patents, foreign patents, or pending applications. TRADEMARKS Sun, Sun Microsystems, the Sun logo, SunSoft, the SunSoft logo, Solaris, SunOS, OpenWindows, DeskSet, ONC, ONC+, and NFS are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries. UNIX is a registered trademark in the United States and other countries, exclusively licensed through X/Open Company, Ltd. OPEN LOOK is a registered trademark of Novell, Inc.
    [Show full text]