Sun SPARC Enterprise T5440 Servers
Total Page:16
File Type:pdf, Size:1020Kb
Sun SPARC Enterprise® T5440 Server Just the Facts SunWIN token 526118 December 16, 2009 Version 2.3 Distribution restricted to Sun Internal and Authorized Partners Only. Not for distribution otherwise, in whole or in part T5440 Server Just the Facts Dec. 16, 2009 Sun Internal and Authorized Partner Use Only Page 1 of 133 Copyrights ©2008, 2009 Sun Microsystems, Inc. All Rights Reserved. Sun, Sun Microsystems, the Sun logo, Sun Fire, Sun SPARC Enterprise, Solaris, Java, J2EE, Sun Java, SunSpectrum, iForce, VIS, SunVTS, Sun N1, CoolThreads, Sun StorEdge, Sun Enterprise, Netra, SunSpectrum Platinum, SunSpectrum Gold, SunSpectrum Silver, and SunSpectrum Bronze are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the United States and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. UNIX is a registered trademark in the United States and other countries, exclusively licensed through X/Open Company, Ltd. T5440 Server Just the Facts Dec. 16, 2009 Sun Internal and Authorized Partner Use Only Page 2 of 133 Revision History Version Date Comments 1.0 Oct. 13, 2008 - Initial version 1.1 Oct. 16, 2008 - Enhanced I/O Expansion Module section - Notes on release tabs of XSR-1242/XSR-1242E rack - Updated IBM 560 and HP DL580 G5 competitive information - Updates to external storage products 1.2 Nov. 18, 2008 - Number of (X)6000A crypto accelerator adapters corrected to 2 - Updates to Solaris patch and firmware to allow more flexible configurations - Inclusion of table of field replaceable units (FRUs) - Inclusion of published benchmark results - Updates to competitive information - Updates to matrix of external storage products 1.3 March 4, 2009 - Updated SPECjAppServer2004 benchmark result for T5440 - Updates to I/O Expansion unit - Updates to configuration rules for unequal memory, 1 and 3 socket systems - Inclusion of Sun Fire X4450 in competitive chart - New configuration rules for SSDs - New section entitled Telemetry Recording under Service Processor 1.4 April 23, 2009 - Additional power cords/jumper cables - (X)4447A-Z adapters corrected for consistency ATO vs. X-option 2.0 July 21, 2009 - Updates for 1.6 Ghz offerings, including order, competitive and benchmarks 2.1 Aug 12, 2009 - Corrected number of (X)4447A-Z supported 2.2 Oct 20, 2009 - Revised number of (X)4447A-Z supported, with qualifications noted - Inclusion of X1106A-Z and X1107A-Z (Oplin) - New restriction: one processor systems should not use PCIe slots 4 – 7, except for XAUI. Revised PCIe Slot Guidelines section. - Part number for 50 GB SSD - Part number for OpenSolaris 2009.06 for ATO only - PCIe storage accelerators (Aura) - Future 2.3 Dec 16, 2009 - Remove reference to Try & Buy program, ended on Dec. 18, 2009 T5440 Server Just the Facts Dec. 16, 2009 Sun Internal and Authorized Partner Use Only Page 3 of 133 Table of Contents Copyrights.........................................................................................................................................................2 Revision History.................................................................................................................................................3 Sun SPARC Enterprise® T5440 Server Highlights............................................................................................9 Introduction.........................................................................................................................................................12 Key Features Summary...................................................................................................................................12 Key Messages For The Sun SPARC Enterprise T5440 Servers.....................................................................13 Product Family Placement...............................................................................................................................21 Feature Comparison with Other UltraSPARC Servers.....................................................................................23 Feature Comparison with Sun Fire x64, Opteron-based Servers....................................................................24 Selection Criteria................................................................................................................................................27 Sun SPARC Enterprise T-series .....................................................................................................................27 Sun SPARC Enterprise T-series server are optimized for:..............................................................................28 Sun Fire x64 servers excel in these areas:......................................................................................................28 Sun Fire x64 servers are optimized for:..........................................................................................................28 Positioning Comparison with Other UltraSPARC Servers...............................................................................29 Availability........................................................................................................................................................29 Target Users....................................................................................................................................................29 Competitive Positioning.....................................................................................................................................31 Sun SPARC Enterprise T5440 servers ...........................................................................................................31 IBM - Competitive Summary Chart..................................................................................................................34 IBM Power 5 Rack-Optimized Servers ...........................................................................................................39 The Sun SPARC Enterprise T5440 vs. IBM System 550 and 570 Power 6 Servers.......................................40 The Sun SPARC Enterprise T5440 vs. IBM System x Servers, Quad Socket, Competitive Analysis..............41 HP - Competitive Summary Chart....................................................................................................................43 The Sun SPARC Enterprise T5440 vs 4 Socket HP Itanium 2 Servers..........................................................48 Sun SPARC Enterprise T5440 vs HP ProLiant 4RU / Quad Socket Servers...................................................49 Sun SPARC Enterprise T5440 vs. Dell Quad Socket Servers.........................................................................50 Nehalem-based Servers..................................................................................................................................51 Benchmark Results..........................................................................................................................................53 Competitive Services Offerings........................................................................................................................56 The SWaP Metric.............................................................................................................................................57 Selling Strategies................................................................................................................................................58 Enabling Technology..........................................................................................................................................60 The UltraSPARC T2 Plus CMT Processor ......................................................................................................60 System Architecture...........................................................................................................................................63 Design Approach.............................................................................................................................................63 Product Upgrade Paths...................................................................................................................................63 Environmental Controls...................................................................................................................................63 The Sun SPARC Enterprise T5440 Functional Block Diagram........................................................................64 Motherboard....................................................................................................................................................66 CPU Board.......................................................................................................................................................66 Memory............................................................................................................................................................67 I/O Subsystem ................................................................................................................................................68 Network...........................................................................................................................................................68