Urea-Formaldehyde Foam Insulations: a Review of Their Properties and Performance
Total Page:16
File Type:pdf, Size:1020Kb
NBS NATL INST OF STAND & TECH PUBLICATIONS i NI8T U.S. DEPARt A111D7 E^^E57 PU8UCATI0NS National Bureau of Standards NBS Technical Note 1210 Urea-Formaldehyde Foam Insulations: A Review of Their Properties and Performance Walter J, Rossiter, Jr, and Robert G, Mathey NBS NBS NBS NBS NBS NBS NBS NBS NBS NBS iS NBS NBS NBS NBS NBS NBS NBS NBS NBS NB. NBS NBS NBS NBS NBS NBS NBS NBS NBS NBS iS NBS NBS NBS NBS NBS NBS NBS NBS NBS NB. NBS NBS NBS NBS NBS NBS NBS NBS NBS NBS iS NBS NBS NBS NBS NBS NBS NBS NBS NBS NB. NBS NBS NBS NBS NBS NBS NBS NBS NBS NBS iS NBS NBS NBS NBS NBS NBS NBS NBS NBS NB. NBS NBS NBS NBS NBS NBS NBS NBS NBS NBS iS NBS NBS NBS NBS NBS NBS NBS NBS NBS NB. NBS NBS NBS National Bureau ofStandards NBS NBS iS NBS NBS NBS NBS NBS NBS NBS NBS NBS NB. NBS NBS NBS NBS NBS NBS NBS NBS NBS NBS I QC BS NBS NBS NBS NBS NBS NBS NBS NBS NB.\ ;°;„ NBS NBS NBS NBS NBS NBS NBS NBS NBS No. 1210 BS NBS NBS NBS NBS NBS NBS NBS NBS NB. 1985 c. 2 he National Bureau Tm of Standards' was established by an act of Congress on March 3, 1901. The _JL Bureau's overall goal is to strengthen and advance the nation's science and technology and facilitate their effective for application public benefit. To this end, the Bureau conducts research and provides: (1) a basis for the nation's physical measurement system, (2) scientific and technological services for industry and government, (3) a technical basis for equity in trade, and (4) technical services to promote public safety. The Bureau's technical work is performed by the National Measurement Laboratory, the National Engineering Laboratory, the Institute for Computer Sciences and Technology, and the Center for Materials Science. The National Measurement Laboratory Provides the national system of physical and chemical measurement; Basic Standards^ coordinates the system with measurement systems of other nations and Radiation Research furnishes essential services leading to accurate and uniform physical and Chemical Physics chemical measurement throughout the Nation's scientific community, in- Analytical Chemistry dustry, and commerce; provides advisory and research services to other Government agencies; conducts physical and chemical research; develops, produces, and distributes Standard Reference Materials; and provides calibration services. The Laboratory consists of the following centers: The National Engineering Laboratory Provides technology and technical services to the public and private sectors to Applied Mathematics address national needs and to solve national problems; conducts research in Electronics and Electrical engineering and applied science in support of these efforts; builds and main- Engineering^ tains competence in the necessary disciplines required to carry out this Manufacturing Engineering research and technical service; develops engineering data and measurement Building Technology capabilities; provides engineering measurement traceability services; develops Fire Research test methods and proposes engineering standards and code changes; develops Chemical Engineering^ and proposes new engineering practices; and develops and improves mechanisms to transfer results of its research to the ultimate user. The Laboratory consists of the following centers: The Institute for Computer Sciences and Technology Conducts research and provides scientific and technical services to aid • Programming Science and Federal agencies in the selection, acquisition, application, and use of com- Technology puter technology to improve effectiveness and economy in Government • Computer Systems operations in accordance with Public Law 89-306 (40 U.S.C. 759), relevant Engineering Executive Orders, and other directives; carries out this mission by managing the Federal Information Processing Standards Program, developing Federal ADP standards guidelines, and managing Federal participation in ADP voluntary standardization activities; provides scientific and technological ad- visory services and assistance to Federal agencies; and provides the technical foundation for computer-related policies of the Federal Government. The In- stitute consists of the following centers: The Center for Materials Science Conducts research and provides measurements, data, standards, reference Inorganic Materials materials, quantitative understanding and other technical information funda- Fracture and Deformation^ mental to the processing, structure, properties and performance of materials; Polymers addresses the scientific basis for new advanced materials technologies; plans Metallurgy research around cross-country scientific themes such as nondestructive Reactor Radiation evaluation and phase diagram development; oversees Bureau-wide technical programs in nuclear reactor radiation research and nondestructive evalua- tion; and broadly disseminates generic technical information resulting from its programs. The Center consists of the following Divisions: Hcadquariers and l,aboratories at Gailhersburg, MD, unless otherwise noted; mailing address Ciaiihersburg, MD 20899. '.omc divisions within the center are located at Boulder, CO 80303. CKaicd ai Ikjulder. CO, with some elements ai Oaiihersbiirf MD KRTIOfm.1 BUREAU OF STANDARDS UERARY Q-Cyfoo NBS Technical Note 1210 Urea-Formaldehyde Foam Insulations: A Review of Their Properties and Performance Walter J. Rossiter, Jr. Sponsored by: Robert G. Mathey Office of Conservation and Renewable Energy Center for Building Technology Department of Energy National Engineering Laboratory 1000 Independence Ave., S.W. National Bureau of Standards Washington, DC 20585 Gaithersburg, MD 20899 March 1985 \ ^^J «</,"eau o* U.S. Department of Commerce Malcolm Baldrige, Secretary National Bureau of Standards Ernest Ambler, Director \ National Bureau of Standards U.S. Government Printing Office For sale by the Superintendent Technical Note 1210 Washincton: 1985 of Documents. Natl. Bur. Stand. (U.S.), U.S. Government Printing Office. Tech. Note 1210. Washincton. DC 20402 70 pages (Mar. 1985) CODEN: NBTNAE ABSTRACT Urea-formaldehyde foam insulation was commonly used in the mid-to-late 1970s for retrofitting the sidewalls of residences. Many reports describing the use of this material in buildings have been published. This report presents a review of the properties and performance of urea-formaldehyde foams pertinent to their use as thermal insulation for buildings. The review is based primarily on existing published literature. The factors affecting the performance of these insulations are listed and discussed. Included among these factors are durability, effect on energy conservation, effect on other building materials, fungus resistance, shrinkage, and temperature and humidity effects on foam. A key issue involving the use of urea-formaldehyde foam insulation is its release of formaldehyde, other gases, and particulates into the air of resi- dences. Information concerning the release of these agents is summarized. The literature evidence indicates that where formaldehyde measurements have been made, on the average, formaldehyde levels in homes with foam insulation are higher than those without foam. The mechanism of formaldehyde release from foams is not totally understood. A review of remedial actions which may be taken to reduce or eliminate formaldehyde release from foams into residences is given. The information concerning the remedial actions discussed are those primarily being used in Canada. In addition, standards for urea-formaldehyde foam insulations developed in North America and Europe were reviewed and the material property requirements tabulated. The standards do not contain require- ments pertaining to the long-term release of formaldehyde from these foam insulations. Key words: Cellular plastics; energy conservation; formaldehyde; performance factors; remedial actions; retrofit; standards; thermal insulation; urea-formaldehyde foam. iii 1 TABLE OF CONTENTS Page ABSTRACT Ill 1. INTRODUCTION 1 1 . Background 1 1.2 Objectives 2 1.3 Scope of the Study 2 1.4 Urea-Formaldehyde Foam Insulation 3 2. STANDARDS AND USE OF FOAM IN OTHER COUNTRIES 5 2.1 Standards 5 2.2 Adequacy of Standards for Predicting Formaldehyde Release .... 8 2.3 Use of Urea- Formaldehyde Foam Insulation In Other Countries .. 8 3. FACTORS AFFECTING THE PERFORMANCE OF UREA- FORMALDEHYDE FOAM INSULATION 12 3.1 Areas of Application 13 3.2 Cavity Filling 15 3.3 Density 16 3.4 Durability 17 3.5 Effect on Energy Conservation 18 3.6 Effect on Other Building Materials 19 3.6.1 Gypsum Plaster and Wallboard 19 3.6.2 Masonry Materials and Mortar 20 3.6.3 Metals 20 3.6.4 Paints and Coatings 23 3.6.5 Wood 23 3.7 Electrical Properties 25 3.8 Flammability and Combustibility 25 3.9 Fungus Resistance 26 3.10 Off gassing and Release of Particulates 28 3.11 Quality Control of Component Materials 28 3.12 Rain Penetration 28 3.13 Shrinkage 29 3.13.1 The Extent of Shrinkage 29 3.13.2 The Effect of Shrinkage on Thermal Performance 30 3.14 Temperature and Humidity Effects on Foam 32 3.15 Thermal Conductivity 33 3 . 16 Water Absorption 34 V . TABLE OF CONTENTS (CONT.) Page 4. RELEASE OF FORMALDEHYDE, OTHER GASES, AND PARTICULATES 36 4.1 Formaldehyde Release 36 4.1.1 Formaldehyde Levels in Residences 36 4.1.2 Formaldehyde Measurement 38 4.1.3 Mechanism of Formaldehyde Release 40 4.1.4 Effects of Application Parameters on Formaldehyde Release 41 4.1.5 Formaldehyde Release and Standards for Urea- formaldehyde Foams 41 4.2 Release of Gases Other Than Formaldehyde 42 4.3 Release of Particulates 42 5 REMEDIAL MEASURES 43 5.1 Present Practices 43 5.1.1 Problem Identification 44 5.1.2 Understanding the Nature of Urea-formaldehyde Foam Insulation 45 5.1.3 Understanding Air and Vapor Movement in Residences .... 45 5.1.4 Knowledge of the Type of Construction 46 5.1.5 Types of Remedial Measures 46 5.2 Effectiveness of Remedial Actions 47 5.3 Research on Urea-Formaldehyde Foam Insulation 48 6 SUMMARY 50 7. REFERENCES 54 8 ACKNOWLEDGEMENTS 64 vi 1. INTRODUCTION 1.1 BACKGROUND Prior to 1973, energy costs were low and little attention was paid to effective use of energy in homes [1]. Many residences were constructed without being adequately insulated in the ceilings, walls, and floors.