NFPA 96 and ICC Standards and Codes with Regard to Commercial Kitchen Systems

Total Page:16

File Type:pdf, Size:1020Kb

NFPA 96 and ICC Standards and Codes with Regard to Commercial Kitchen Systems Comparative Matrix A Comparison of the NFPA 96 and ICC Standards and Codes with regard to Commercial Kitchen Systems Matrix © 2008 First Edition Comparative Matrix © 2008 Phil Ackland First Edition 1 This document was designed to compliment the 18-part Inspecting Commercial Kitchens Online Program by Phil Ackland This is copyrighted material DO NOT reproduce. Many of the NFPA 96 Standards are paraphrased. This document is a guide only and not a legal document. Interpretations do not reflect opinions of either the NFPA or ICC. We recommend that you purchase a current copy of both Code documents. NFPA Disclaimer Portions of this document are reprinted with permission from NFPA 96 -- 2008, Ventilation Control and Fire Protection of Commercial Cooking Operations, copyright © 2008, NFPA. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which represented solely by the standard in its entirety. ICC Disclaimer Portions of this seminar/publication reproduce sections of the 2006 International Mechanical Code, International Code Council, Inc Washington, D.C. Reproduced with permission. All rights reserved. Acknowledgement We want to express our appreciation for this document to Scott Stookey of ICC, Steve Bradbury, Rory Wilson, Jim Roberts, Brian Ringwelski, George Zawacki, Kathy and Doug Bell and others. First Edition Issues -- If you notice any typographical error, please communicate them to the author. For more information on Commercial Kitchen Systems Contact Phil Ackland 250-494-1361 [email protected] or our website www.philackland.com Comparative Matrix © 2008 Phil Ackland First Edition 2 Please Note: The following "Conversion Table" is generally in the order that the information appears within the Power Point presentation. There is some repetition and other areas where it is best to look up the exact quote from your copy of you local Fire Code. Because jurisdictions will modify any of the Codes to suit their purposes and priorities differ, we can not claim accuracy in the following table. Where in PP NFPA 96 – 2008 Ed. IMC 2006 Ed. Administration NFPA 96, Chapter 1.1.1*: (Para) This standard provides only the 506.1 General. Commercial kitchen hood ventilation ducts and minimum fire safety requirements exhaust equipment shall comply with the requirements of this section. Commercial kitchen grease ducts shall be designed for the type of cooking appliance and hood served. IFC [M] 610.1 General. Commercial kitchen exhaust hoods shall comply with the requirements of the International Mechanical Code. IFC [M] 610.2 Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Administration NFPA 96, Chapter 1.2: (Para) The purpose of this standard shall be to 509.1 Where required. – Commercial cooking appliances required by reduce the potential fire hazard of cooking operations Section 507.2.1 to have a Type I hood shall be provided with an approved automatic fire suppression system complying with the International Building Code and the International Fire Code. Administration 102.1 Scope - This code shall regulate the design, installation, maintenance, alteration and inspection of mechanical systems that are permanently installed and utilized to provide control of environmental conditions and related processes within buildings. This code shall also regulate those mechanical systems, system components, equipment and appliances specifically addressed herein. The installation of fuel gas distribution piping and equipment, fuel gas-fired appliances and fuel gas-fired appliance venting systems shall be regulated by the International Fuel Gas Code. Exception: Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means of egress and their accessory structures shall comply with the International Residential Code. Comparative Matrix © 2008 Phil Ackland First Edition 3 Administration NFPA 96, Chapter 1.1.4: This standard shall not apply to facilities No equivalent section in the IMC. where all of the following are met: (1) Only residential equipment is being used. (2) Fire extinguishers located in all kitchen areas in accordance with NFPA 10, Standard for Portable Fire Extinguishers. (3) Facility is not assembly occupancy. (4) Subject to the approval of the authority having jurisdiction. Administration NFPA 96, Chapter 1.3.1: This standard shall be applied as a united 102.8 Referenced codes and standards. The codes and standards whole. referenced herein shall be those that are listed in Chapter 15 and such codes and standards shall be considered as part of the requirements of this code to the prescribed extent of each such reference. Where differences occur between provisions of this code and the referenced standards, the provisions of this code shall apply. Administration NFPA 96, Chapter 1.3.2: (Para) The authority having jurisdiction 104.1 General. The code official shall enforce the provisions of this determines compliance and equivalence. code and shall act on any question relative to the installation, alteration, repair, maintenance or operation of mechanical systems, except as otherwise specifically provided for by statutory requirements or as provided for in Sections 104.2 through 104.8. Retroactivity NFPA 96, Chapter 1.4 Retroactivity. This standard reflects a consensus No equivalent section in the IMC of acceptable degrees of protection. Retroactivity NFPA 96, Chapter 1.4.2: In cases of unacceptable risk, the authority 102.2 Existing installations. Except as otherwise provided for in this having jurisdiction shall be permitted to apply the #96 retroactively chapter, a provision in this code shall not require the removal, alteration or abandonment of, nor prevent the continued utilization and maintenance of, a mechanical system lawfully in existence at the time of the adoption of this code. Equivalency NFPA 96, Chapter 1.5 Equivalency. This standard does not limit the 105.2 Alternative materials, methods, equipment and appliances. use of other methods or devices that satisfy the AHJ.. The provisions of this code are not intended to prevent the installation of any material or to prohibit any method of construction not specifically prescribed by this code, provided that any such alternative has been approved. An alternative material or method of construction shall be approved where the code official finds that the proposed design is satisfactory and complies with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended, at least the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety. Comparative Matrix © 2008 Phil Ackland First Edition 4 Listed Components NFPA 96, Chapter 3.2.4: Listed. Equipment, materials, or services Section 202 General Definitions acceptable to the authority having jurisdiction are permitted. LISTED. Equipment, appliances or materials included in a list published by a nationally recognized testing laboratory, inspection agency or other organization concerned with product evaluation that maintains periodic inspection of production of listed equipment, appliances or materials, and whose listing states either that the equipment, appliances or material meets nationally recognized standards or has been tested and found suitable for use in a specified manner. Not all testing laboratories, inspection agencies and other organizations concerned with product evaluation use the same means for identifying listed equipment, appliances or materials. Some do not recognize equipment, appliances or materials as listed unless they are also labeled. The authority having jurisdiction shall utilize the system employed by the listing organization to identify a listed product. General Requirements NFPA 96, Chapter 11.1.4: Instructions for manually operating the fire extinguishing system shall be posted conspicuously in the kitchen and Owner’s shall be reviewed with employees by the management. Responsibilities - Staff Training General Requirements NFPA 96, Chapter 4.1.1: Smoke or grease-laden vapor producing 507.1 General. – Commercial kitchen exhaust hoods shall comply with appliances require an exhaust system that complies with the entire the requirements of this section. Hoods shall be Type I or Type II and standard. shall be designed to capture and confine cooking vapors and residues. IFC [M] 610.1 General. – Commercial kitchen exhaust hoods shall comply with the requirements of the International Mechanical Code. IFC [M] 610.2 Where required. – A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. General Requirements 4.1.9* Cooking equipment used in fixed, mobile, or temporary No equivalent section in the IMC or IFC concessions, such as trucks, buses, trailers, pavilions, tents, or any form of roofed enclosure, shall comply with this standard. Comparative Matrix © 2008 Phil Ackland First Edition 5 General Requirements NFPA 96, Chapter 4.6 Drawings. A drawing (s) of the exhaust system IFC 901.6.2 Records. Records of all system inspections, tests and and operating instructions shall be kept on the premises. maintenance required by the referenced standards shall be maintained on the premises for a minimum of three years and shall be
Recommended publications
  • Gaylord Clearair Ventilator
    NATIONAL BUREAU OF STANDARDS REPORT 3171 GAYLORD CLEARAIR VENTILATOR by Carl W. Coblentz Paul R. Achenbach Report to Bureau of Ships Department of the Navy U. S. DEPARTMENT OF COMMERCE NATIONAL BUREAU OF STANDARDS U. S. DEPARTMENT OF COMMERCE Sinclair Weeks, Secretary NATIONAL BUREAU OF STANDARDS A. V. Astin, Director THE NATIONAL BUREAU OF STANDARDS The scope of activities of the National Bureau of Standards is suggested in the following listing of the divisions and sections engaged in technical work. In general, each section is engaged in special- ized research, development, and engineering in the field indicated by its title. A brief description of the activities, and of the resultant reports and publications, appears on the inside of the back cover of this report. Electricity. Resistance and Reactance Measurements. Electrical Instruments. Magnetic Measurements. Electrochemistry. Optics and Metrology. Photometry and Colorimetry. Optical Instruments. Photographic Technology. Length. Engineering Metrology. Heat and Power. Temperature Measurements. Thermodynamics. Cryogenic Physics. Engines and Lubrication. Engine Fuels. Cryogenic Engineering. Atomic and Radiation Physics. Spectroscopy. Radiometry. Mass Spectrometry. Solid State Physics. Electron Physics. Atomic Physics. Neutron Measurements. Infrared Spectros- copy. Nuclear Physics. Radioactivity. X-Ray. Betatron. Nucleonic Instrumentation. Radio- logical Equipment. Atomic Energy Commission Radiation Instruments Branch. Chemistry. Organic Coatings. Surface Chemistry. Organic Chemistry. Analytical Chemistry. Inorganic Chemistry. Electrodeposition. Gas Chemistry. Physical Chemistry. Thermochemistry. Spectrochemistry. Pure Substances. Mechanics. Sound. Mechanical Instruments. Fluid Mechanics. Engineering Mechanics. Mass and Scale. Capacity, Density, and Fluid Meters. Combustion Control. Organic and Fibrous Materials. Rubber. Textiles. Paper. Leather. Testing and Specifica- tions. Polymer Structure. Organic Plastics. Dental Research. Metallurgy. Thermal Metallurgy. Chemical Metallurgy.
    [Show full text]
  • Guideline on Through Penetration Firestopping
    GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING SECOND EDITION – AUGUST 2007 SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 www.smacna.org GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING Copyright © SMACNA 2007 All Rights Reserved by SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 Printed in the U.S.A. FIRST EDITION – NOVEMBER 1996 SECOND EDITION – AUGUST 2007 Except as allowed in the Notice to Users and in certain licensing contracts, no part of this book may be reproduced, stored in a retrievable system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of the publisher. FOREWORD This technical guide was prepared in response to increasing concerns over the requirements for through-penetration firestopping as mandated by codes, specified by system designers, and required by code officials and/or other authorities having jurisdiction. The language in the model codes, the definitions used, and the expectations of local code authorities varies widely among the model codes and has caused confusion in the building construction industry. Contractors are often forced to bear the brunt of inadequate or confusing specifications, misunderstandings of code requirements, and lack of adequate plan review prior to construction. This guide contains descriptions, illustrations, definitions, recommendations on industry practices, designations of responsibility, references to other documents and guidance on plan and specification requirements. It is intended to be a generic educational tool for use by all parties to the construction process. Firestopping Guideline • Second Edition iii FIRE AND SMOKE CONTROL COMMITTEE Phillip E.
    [Show full text]
  • Grease Duct Enclosures Fire and Smoke Dampers in Grease Ducts
    506.3.11 CHANGE TYPE: Modification CHANGE SUMMARY: The code specifically prohibits the installation of Grease Duct Enclosures fire and smoke dampers in grease ducts. 2015 CODE: 506.3.11 Grease Duct Enclosures. A commercial kitchen grease duct serving a Type I hood that penetrates a ceiling, wall, floor or any concealed spaces shall be enclosed from the point of penetration to the outlet terminal. In-line exhaust fans not located outdoors shall be enclosed as required for grease ducts. A duct shall penetrate exterior walls only at locations where unprotected openings are permitted by the International Building Code. The duct enclosure shall serve a single grease duct and shall not contain other ducts, piping or wiring systems. Duct enclosures shall be either a shaft enclosure in accordance with Section 506.3.11.1, a field-ap- plied enclosure assembly in accordance with 506.3.11.2 or a factory-built enclosure assembly in accordance with Section 506.3.11.3. Duct enclosures shall have a fire-resistance rating of not less than that of the assembly pen- etrated and not less than 1 hour. Fire dampers and smoke dampers shall not be installed in grease ducts. Duct enclosures shall be as prescribed by Section 506.3.11.1, 506.3.11.2 or 506.3.11.3. 506.3.11.4 Duct enclosure not required. This excerpt is taken from Exception: A duct enclosure shall not be required for a grease duct Significant Changes to the that penetrates only a non-fire-resistance-rated roof/ceiling assembly. International Plumbing/ CHANGE SIGNIFICANCE: It has long been understood that fire and smoke dampers are not compatible with grease ducts, and the duct en- Mechanical/ closure requirements clearly account for the lack of such dampers where Fuel Gas the ducts penetrate walls, floors and ceilings.
    [Show full text]
  • Life Safety Dampers Selection and Application Manual • Ceiling Radiation Dampers • Fire Dampers • Combination Fire Smoke Dampers • Smoke Dampers
    Life Safety Dampers Selection and Application Manual • Ceiling Radiation Dampers • Fire Dampers • Combination Fire Smoke Dampers • Smoke Dampers August 2016 1 Table of Contents HOW TO USE THIS MANUAL DAMPER APPLICATION 3 • Fire Damper Application • Smoke Damper Application • Combination Fire Smoke Damper Application • Corridor Ceiling Combination Fire Smoke Damper Application DAMPER SELECTION 5 • Selection Process • Key Points to Remember ACTUATOR SELECTION 7 • Selection Process • Actuator Mounting Options • Key Points to Remember SLEEVE REQUIREMENTS 9 • Sleeve Thickness • Sleeve Length • Key Points to Remember SPACE REQUIREMENTS FOR PROPER INSTALLATION 10 • Key Points to Remember DAMPER OPTIONS 11 • Control Options • Security Bar Options • Transition Options • Key Points to Remember INSTALLATION REQUIREMENTS 15 • Combination Fire Smoke Damper Installation • Smoke Damper Installation • Actuator Installation • Damper and Actuator Maintenance • Key Points to Remember SPECIAL INSTALLATION CASES 17 • Maximum Damper Size Limitations • Horizontal Fire Smoke Damper in a Non-Concrete Barrier • AMCA Mullion System • What if a Damper Cannot be Installed per the Manufacturer’s Installation Instructions? • What if a Damper Cannot be Installed in the Wall? • Steps to Take When an Unapproved Installation Must be Provided CEILING RADIATION DAMPERS 20 • Ceiling Radiation Damper Application • Key Points to Remember CODES AND STANDARDS 21 • Compliance with the Applicable Building Codes • The National Fire Protection Association • Code and Standard Making
    [Show full text]
  • Basis of Design
    UNIVERSITY OF WASHINGTON Mechanical Facilities Services Heating Ventilation and Air Conditioning Design Guide Ductwork and Duct Accessories Basis of Design This section applies to the design and installation of ductwork, air terminal boxes, air outlets and inlets, volume dampers, pressure relief dampers, smoke/fire dampers, and smoke/fire damper actuators. Design Criteria Select duct velocities to meet N.C. requirements of each occupied space. NC level requirements shall be identified in the Basis of Design narrative. Coordinate required NC levels with University Project Manager and users. Supply, Return and Non Fume Exhaust Ductwork Provide a 6-inch pressure rating for supply ductwork and plenums between the supply fan and the zone terminal boxes; for ductwork downstream of the terminal box, provide a 2-inch pressure rating. If pressure classes less than those given above are considered sufficient for a specific application, review with Engineering Services before specifying a lower rating. Use the ASHRAE Handbook of Fundamentals chapter on duct design to determine the allowable leakage rate (cfm/100 sq.ft.) at the specified test pressure for each type of ductwork on the project other than fume exhaust ductwork. Specify for each type of ductwork the duct pressure rating, the pressure to apply during the duct leakage test, and the allowable cfm/100 sq.ft. leakage rate at the test pressure. Minimize use of square elbows. Provide turning vanes in square elbows of supply ductwork. Do not use turning vanes in return or exhaust ductwork. To minimize noise levels in the space, specify balancing dampers in lieu of registers. Provide a balancing damper for each outlet and each inlet.
    [Show full text]
  • Data Sheets 1-45 January 2018 Page 1 of 20
    FM Global Property Loss Prevention Data Sheets 1-45 January 2018 Page 1 of 20 AIR CONDITIONING AND VENTILATING SYSTEMS Table of Contents Page 1.0 SCOPE ..................................................................................................................................................... 3 1.1 Changes ............................................................................................................................................ 3 1.2 Hazard .............................................................................................................................................. 3 2.0 LOSS PREVENTION RECOMMENDATIONS ....................................................................................... 3 2.1 Construction and Location ............................................................................................................... 3 2.1.1 Ducts ....................................................................................................................................... 3 2.1.2 Automatic Fire Doors and Fire Dampers ............................................................................... 5 2.1.3 Air Filters ................................................................................................................................ 7 2.1.4 Fans, Air Intakes, and Outlets ................................................................................................ 7 2.1.5 Design ...................................................................................................................................
    [Show full text]
  • Fire/Smoke Dampers
    Fire/Smoke Dampers Ontario Building Code 2020: New Provisions for Fire & Smoke Dampers Fire & Smoke Dampers • Fire Separation & Fire Compartments • Fire Dampers • Smoke Dampers • OBC 2020: Fire/Smoke Damper Requirements • OBC 2020: Fire/Smoke Dampers Waived • OBC 2020: Installation Requirements • Installation Example Fire Separation • Fire Separation is the method of protecting buildings from the spread of fire to adjoining rooms. • Fire Separation is required when the function of a room meets the criteria outlined in section 3.3 of the OBC, or in their respective governing standard. Fire Separation • Fire Separation is achieved by • Fire-rated Building Materials come separating a space with approved with different ratings, commonly materials listed to have a fire ranging from 20 minutes to 3 rating. hours. – Walls, Floors & Ceilings – Doors – Ducts & Penetrations Fire Compartments • Fire Compartments: an • Fire Compartments are required architectural method to protect when the function of a room meets adjacent spaces from flame & the criteria outlined in section 3.3 smoke migration. of the OBC, or in their respective governing standard. Fire Dampers • Fire Dampers: – Close automatically upon detection of heat to maintain fire separation – Driving mechanism is typically a fuseable link that melts when the minimum temperature is met – Low-Cost. Come in a variety of types Smoke Dampers • Smoke Dampers: – Close automatically upon detection of smoke to maintain fire separation – Electronically or pneumatically driven, controlled by smoke detectors and/or fire alarm systems – When activated, smoke dampers must meet CAN/ULC-S112.1 “Leakage Rated Dampers for use in Smoke-Controlled Systems” and conform to Class I, II, or III of that standard.
    [Show full text]
  • Fire Damper Installation, Operation & Maintenance
    FIRE DAMPER INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS R8218 UL/ULC File: R8218 New York BSA/MEA Listing: 79-03-M California State Fire Marshall Listing: 3225-1721:0102 The following installation instructions are UL approved to be used with the following NCA Models: FD, FD-SL, FD-N, FD-USL, FD-MB-3V, FD-MB-AF, FD-3V-SB, FDD, FDD-SL, FDD-MB-3V, and FDD-MB- AF. Installation Supplements: - Installing Fire and Combination Fire/Smoke Dampers in a Shaft Wall - Framing Requirements for Wood or Steel Stud Walls Application & General Notes: - UL Approved Breakaway Duct Connections - Optional Sealing of Dampers in Fire and Smoke These installation instructions apply to Fire Dampers of the stat- Rated Walls or Floors ic, dynamic, curtain-style, single and multi-blade types mounted - Fabrication and Installation of Support Mullions in the plane of a UL* approved fire partition. For dampers needed - Field Modification of Factory Supplied Sleeves to be installed outside the plane of a UL approved wall or floor, - Security Bars for Fire and Fire/Smoke Dampers refer to the Out of Wall Fire and Fire/Smoke Damper IOM. The - Installing Fire and Fire/Smoke Dampers in Concrete dampers are designed for operation in the vertical or horizontal Floor with Steel Deck orientation with blades running horizontal. Safety Warning: Other Installation References: - Out-of-Wall Fire and Fire/Smoke Damper IOM Read all installation, operating and maintenance instructions - True Round Fire and Fire/Smoke Damper IOM thoroughly before installing or servicing this equipment. Improp- er installation, adjustment, alteration, service or maintenance can cause property damage, injury or death.
    [Show full text]
  • Specification 541 Rev. 1 – General Construction of HVAC Installations
    TABLE OF CONTENTS 1.0 SCOPE .............................................................................................................................................. 5 2.0 STANDARDS, CODES AND SPECIFICATIONS ............................................................................. 6 2.1 GENERAL SPECIFICATIONS ......................................................................................................................... 6 2.2 STANDARDS AND CODES ........................................................................................................................... 6 2.3 CERTIFICATION ................................................................................................................................................ 6 3.0 SERVICE CONDITIONS .................................................................................................................. 7 3.1 ENVIRONMENTAL CONDITIONS .............................................................................................................. 7 4.0 GENERAL REQUIREMENTS ........................................................................................................... 8 4.1 DRAWINGS AND SPECIFICATIONS .......................................................................................................... 8 4.2 MATERIAL, WORKMANSHIP AND SUITABILITY .................................................................................. 9 4.3 AREA CLASSIFICATION ................................................................................................................................
    [Show full text]
  • Dampers and Actuators Catalog for the Latest Product Updates, Visit Us Online at > Johnsoncontrols.Com
    Dampers and Actuators Catalog for the latest product updates, visit us online at > johnsoncontrols.com > johnsoncontrols.com > Building Efficiency > Integrated HVAC Systems > HVAC Control Products > Rectangular Dampers > Round Dampers > Air Control Products II Johnson Controls delivers products, services and solutions that increase energy efficiency and lower operating costs in buildings for more than one million customers. Operating from 500 branch offices in 148 countries, we are a leading provider of equipment, controls and services for heating, ventilating, air-conditioning, refrigeration and security systems. We have been involved in more than 500 renewable energy projects including solar, wind and geothermal technologies. Our solutions have reduced carbon dioxide emissions by 13.6 million metric tons and generated savings of $7.5 billion since 2000. Many of the world’s largest companies rely on us to manage 1.8 billion square feet of their commercial real estate. HVAC Dampers, Louvers and Air Control Products Since 1905, Johnson Controls has manufactured industry-leading temperature control dampers. Today, we offer a complete line of HVAC dampers and air control products including volume control, balancing, round, zone, fire, smoke and combined models. Johnson Controls is committed to customer satisfaction, and that’s why we custom-build each of our HVAC dampers to suit your specific size and model requirements. Some dampers can even be manufactured one day and shipped the next day. Actuators and accessories can be ordered with the damper and factory-installed or shipped separately depending on your needs. > Round Dampers III Introduction to Dampers The Selection Process Parallel vs Opposed Blade Operation Selecting the right damper is important to assure good Parallel blades rotate so they are always parallel to each operating characteristics in any airflow system, helping other; therefore, at any partially open position, they you maximize energy efficiency and minimize tend to redirect airflow and increase turbulence and installation costs.
    [Show full text]
  • Duct Systems
    CHAPTER 6 DUCT SYSTEMS SECTION 601 ponent of an approved engineered smoke control GENERAL system. 601.1 Scope. Duct systems used for the movement of air in [B] 601.3 Exits. Equipment and ductwork for exit enclosure air-conditioning, heating, ventilating and exhaust systems ventilation shall comply with one of the following items: shall conform to the provisions of this chapter except as oth- 1. Such equipment and ductwork shall be located exterior erwise specified in Chapters 5 and 7. to the building and shall be directly connected to the Exception: Ducts discharging combustible material exit enclosure by ductwork enclosed in construction as directly into any combustion chamber shall conform to the required by the Building Code for shafts. requirements of NFPA 82. 2. Where such equipment and ductwork is located within [B] 601.2 Air movement in egress elements. Corridors shall the exit enclosure, the intake air shall be taken directly not serve as supply, return, exhaust, relief or ventilation air from the outdoors and the exhaust air shall be dis- ducts. charged directly to the outdoors, or such air shall be conveyed through ducts enclosed in construction as Exceptions: required by the Building Code for shafts. 1. Use of a corridor as a source of makeup air for 3. Where located within the building, such equipment and exhaust systems in rooms that open directly onto ductwork shall be separated from the remainder of the such corridors, including toilet rooms, bathrooms, building, including other mechanical equipment, with dressing rooms, smoking lounges and janitor clos- construction as required by the Building Code for ets, shall be permitted, provided that each such cor- shafts.
    [Show full text]
  • Fire Induced Flow in Building Ventilation Systems (2016)
    Aalto University School of Engineering Degree programme in Mechanical Engineering Fire Induced Flow in Building Ventilation Systems Master’s Thesis 01.03.2016 Rahul Kallada Janardhan Thesis submitted in partial fulfilment of the requirements for the degree of Master of Science in Technology. Espoo, March 1, 2016 Supervisor: Prof. Simo Hostikka Advisor: Timo Korhonen 1 Author: Rahul Kallada Janardhan Title: Fire Induced Flows in Building Ventilation Systems Date: 01.03.2015 Pages: 69 + 31 Major: Mechanical Engineering Code: IA3027 Supervisor: Professor Simo Hostikka Advisor: Timo Korhonen Fast growing fires inside compartments with limited paths for expanded gases to escape leads to a rapid pressure rise. High pressure can cause smoke to flow through supply vents into the adjacent rooms and can also cause structural damage. In Finland, apartments are fitted with a distinctive double door system and the inner door opens inwards into the apartment. The opening of this door could be difficult under high pressure conditions and the effect of pressure on egress possibilities of occupants was an issue of discussion in Finland. Extensive studies have not been made to better understand the influence of ventilation networks on pressure and smoke spread possibilities. The main objective of this thesis work is to investigate the development of pressure during fires in residential buildings and the influence of ventilation networks on pressure and smoke spread through buildings. It also aims to validate the efficiency and accuracy of the CFD code, Fire Dynamics Simulator for modelling HVAC networks and provide fire safety designers with guidelines to model and simulate pressure development and ventilation system response.
    [Show full text]