Principle of Duct Design in HVAC Systems
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Common Duct Insulation Materials Supplement F
Supplement F Common Duct Insulation Materials The Washington State Energy Code (WSEC) Hotline has received questions about different types and thicknesses of duct insulation. There appears to be some confusion about Table 5-11 of the WSEC which lists the minimum densities, out-of-packages thickness and R-values for different types of duct insulation. Table F-1 shows what the R-values are for varying thicknesses and types of duct insulation in a better layout than Table 5-11. This table also lists the ASTM and UL. Table F-1 R-Values for Common Duct Insulation Materials Installed R-Value1 Typical Material meeting or exceeding the given R-value2 (h.°F sq.ft.)/Btu 1/2-inch Mineral fiber duct liner per ASTM C 1071, Type I 1.9 1-inch Mineral fiber duct wrap per ASTM C 1290 1-inch Mineral fiber duct liner per ASTM C 1071, Types I & II 1-inch Mineral fiber board per ASTM C 612, Types I & IB 3.5 1-inch Mineral fiber duct board per UL 181 1-1/2-inch Mineral fiber duct wrap per ASTM C 1290 1-inch Insulated flex duct per UL 181 1-1/2-inch Mineral fiber duct liner per ASTM C 1071 1-1/2-inch Mineral fiber duct board per UL 181 1-1/2-inch Mineral fiber board per ASTM C 612, Types IA & IB 6.0 2-inch, 2 lb/cu.ft. Mineral fiber duct wrap per ASTM C 1290 2-1/2-inch, .6 to 1 lb/cu.ft. Mineral fiber duct wrap per ASTM C 1290 2-1/2-inch Insulated flex duct per UL 181 2-inch Mineral fiber duct liner per ASTM C 1071, Types I & II 2-inch Mineral fiber Duct board per UL 181 8.0 2-inch Mineral fiber board per ASTM C 612, Types 612, Types I! & IB 3-inch 3/4 lb/cu.ft. -
HVAC Controls (DDC/EMS/BAS) Evaluation Protocol
Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures Created as part of subcontract with period of performance September 2011 – December 2014 Jeff Romberger SBW Consulting, Inc. Bellevue, Washington NREL Technical Monitor: Charles Kurnik NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Operated by the Alliance for Sustainable Energy, LLC This report is available at no cost from the National Renewable Energy Laboratory (NREL) at www.nrel.gov/publications. Subcontract Report NREL/SR-7A40-63167 November 2014 Contract No. DE-AC36-08GO28308 Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures Created as part of subcontract with period of performance September 2011 – December 2014 Jeff Romberger SBW Consulting, Inc. Bellevue, Washington NREL Technical Monitor: Charles Kurnik Prepared under Subcontract No. LGJ-1-11965-01 NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Operated by the Alliance for Sustainable Energy, LLC This report is available at no cost from the National Renewable Energy Laboratory (NREL) at www.nrel.gov/publications. National Renewable Energy Laboratory Subcontract Report 15013 Denver West Parkway NREL/SR-7A40-63167 Golden, CO 80401 November 2014 303-275-3000 • www.nrel.gov Contract No. DE-AC36-08GO28308 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. -
Gaylord Clearair Ventilator
NATIONAL BUREAU OF STANDARDS REPORT 3171 GAYLORD CLEARAIR VENTILATOR by Carl W. Coblentz Paul R. Achenbach Report to Bureau of Ships Department of the Navy U. S. DEPARTMENT OF COMMERCE NATIONAL BUREAU OF STANDARDS U. S. DEPARTMENT OF COMMERCE Sinclair Weeks, Secretary NATIONAL BUREAU OF STANDARDS A. V. Astin, Director THE NATIONAL BUREAU OF STANDARDS The scope of activities of the National Bureau of Standards is suggested in the following listing of the divisions and sections engaged in technical work. In general, each section is engaged in special- ized research, development, and engineering in the field indicated by its title. A brief description of the activities, and of the resultant reports and publications, appears on the inside of the back cover of this report. Electricity. Resistance and Reactance Measurements. Electrical Instruments. Magnetic Measurements. Electrochemistry. Optics and Metrology. Photometry and Colorimetry. Optical Instruments. Photographic Technology. Length. Engineering Metrology. Heat and Power. Temperature Measurements. Thermodynamics. Cryogenic Physics. Engines and Lubrication. Engine Fuels. Cryogenic Engineering. Atomic and Radiation Physics. Spectroscopy. Radiometry. Mass Spectrometry. Solid State Physics. Electron Physics. Atomic Physics. Neutron Measurements. Infrared Spectros- copy. Nuclear Physics. Radioactivity. X-Ray. Betatron. Nucleonic Instrumentation. Radio- logical Equipment. Atomic Energy Commission Radiation Instruments Branch. Chemistry. Organic Coatings. Surface Chemistry. Organic Chemistry. Analytical Chemistry. Inorganic Chemistry. Electrodeposition. Gas Chemistry. Physical Chemistry. Thermochemistry. Spectrochemistry. Pure Substances. Mechanics. Sound. Mechanical Instruments. Fluid Mechanics. Engineering Mechanics. Mass and Scale. Capacity, Density, and Fluid Meters. Combustion Control. Organic and Fibrous Materials. Rubber. Textiles. Paper. Leather. Testing and Specifica- tions. Polymer Structure. Organic Plastics. Dental Research. Metallurgy. Thermal Metallurgy. Chemical Metallurgy. -
Whole-House Duct Mount Hepa Air Cleaner
MODEL DA-HEPADM400-VS WHOLE-HOUSE DUCT MOUNT HEPA AIR CLEANER Description The DIRECT AIR Whole House Duct Mount HEPA Cabinet Construction Features Air Cleaner has been designed to remove atmospheric and household dust, coal dust, One piece wrap, steel cabinet has powder-coat insecticide dust, mites, pollen, mold spores, fungi, paint finish to provide rigid installation and durabil- bacteria, viruses, pet dander, cooking smoke and ity. grease, tobacco smoke particles, and more down Pre-punched openings at back of unit and mount- to 0.3 micron (1/84,000 of an inch) with 99.97% ing template are provided for easier duct mount efficiency on the first pass of air. installation; no external ducting required. It’s ideal for homes that have tight space condi- Pre-punched openings at top and bottom of unit tions in their furnace/air conditioning rooms. This facilitate collar mount installation. unit is compact and can be installed directly on the return air vent. It can also be mounted directly to Media Replacement Filters the furnace and collar mounted to the return air duct to save space. PART REPLACE Ideal for homes with allergy, asthma or respiratory NUMBER DESCRIPTION EVERY sufferers, smokers, pets, cooking odors and musti- ness. DMH4-0400 HEPA Media Filter 2-3 years Helps protect and prolong the operating efficiency of the heating and cooling equipment. DMH4-0855 Prefilter, MERV 11 3-6 months Standard Features DMH4-0810 Carbon Prefilter 3-6 months Highly Efficient MERV 11 Prefilter removes lint and hair before they enter HEPA filter. Activated Carbon Prefilter removes odors to ex- tend the life of the HEPA filter. -
How to Perform Mold Inspections
~ 1 ~ HOW TO PERFORM MOLD INSPECTIONS Mold inspection is a specialized type of inspection that goes beyond the scope of a general home inspection. The purpose of this publication is to provide accurate and useful information for performing mold inspections of residential buildings. This book covers the science, properties and causes of mold, as well as the potential hazards it presents to structures and to occupants’ health. Inspectors will learn how to inspect and test for mold both before and after remediation. This text is designed to augment the student’s knowledge in preparation for InterNACHI’s online Mold Inspection Course and Exam (www.nachi.org). This manual also provides a practical reference guide for use on-site at inspections. Authors: Benjamin Gromicko, Director of InterNACHI Online Education, and Executive Producer, NACHI.TV Nick Gromicko, Founder, International Association of Certified Home Inspectors, and Founder, International Association of Certified Indoor Air Consultants Edited by: Kate Tarasenko / Crimea River To order online, visit: www.nachi.org www.IAC2.org www.InspectorOutlet.com Copyright © 2009-2010 International Association of Certified Indoor Air Consultants, Inc. (IAC2) www.IAC2.org All rights reserved. ~ 2 ~ Mold Inspection: Table of Contents Overview…....................................................................................... 3 Section 1: Types of Mold Inspections.............................................. 5 Section 2: IAC2 Mold Inspection Standards…………………………… 9 Section 3: What is Mold? ………………………………………………… -
American Standard Installer's Guide Air Conditioner Heat Pump 4A7Z0
11-BC25D1-7 Installer’s Guide Air Conditioner/Heat Pumps 4A7Z0/4A6Z0 with AccuLinkTM and Charge AssistTM ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service informa- tion pack upon completion of work. These instructions do not cover all variations in systems or provide for every possible contingency to be met in connection with the installation. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to your installing dealer or local distributor. NOTE: The manufacturer recommends installing only approved matched indoor and outdoor systems. All of the manufacture’s split systems are A.H.R.I. rated only with TXV/EEV indoor systems. Some of the benefits of installing approved matched indoor and outdoor split systems are maximum efficiency, optimum performance and the best overall system reliability. Table of Contents Section 1. Safety ..................................................................................... 2 Section 2. Unit Location Considerations.............................................. 3 Section 3. Unit Preparation .................................................................... 5 Section 4. Setting the Unit ..................................................................... 5 Section 5. Refrigerant Line Considerations ......................................... 6 Section -
Guideline on Through Penetration Firestopping
GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING SECOND EDITION – AUGUST 2007 SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 www.smacna.org GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING Copyright © SMACNA 2007 All Rights Reserved by SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 Printed in the U.S.A. FIRST EDITION – NOVEMBER 1996 SECOND EDITION – AUGUST 2007 Except as allowed in the Notice to Users and in certain licensing contracts, no part of this book may be reproduced, stored in a retrievable system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of the publisher. FOREWORD This technical guide was prepared in response to increasing concerns over the requirements for through-penetration firestopping as mandated by codes, specified by system designers, and required by code officials and/or other authorities having jurisdiction. The language in the model codes, the definitions used, and the expectations of local code authorities varies widely among the model codes and has caused confusion in the building construction industry. Contractors are often forced to bear the brunt of inadequate or confusing specifications, misunderstandings of code requirements, and lack of adequate plan review prior to construction. This guide contains descriptions, illustrations, definitions, recommendations on industry practices, designations of responsibility, references to other documents and guidance on plan and specification requirements. It is intended to be a generic educational tool for use by all parties to the construction process. Firestopping Guideline • Second Edition iii FIRE AND SMOKE CONTROL COMMITTEE Phillip E. -
Code-Compliant Solution for Combustible Plenums
Expect More More time savings, lower installation costs More cost savings, more billable square footage More building space, More solutions for code more design flexibility compliant protection of both air and grease ducts FyreWrap®Duct Insulation delivers more to every member of your project team. FyreWrap® Elite™1.5 Duct Insulation is ideal ■ Complies with NFPA 96, ICC and for the insulation of duct systems in hotels, IAPMO Codes. schools, restaurants, high rise condos, ■ Made in USA. medical facilities, research labs, and sports A FyreWrap product specification in arenas and stadiums. This flexible, light- several formats is available at weight duct wrap www.arcat.com; search using keywords provides a single Unifrax, FyreWrap fire protection or www.unifrax.com. solution for both For more information air distribution and grease duct systems. on FyreWrap Elite 1.5 FyreWrap Elite 1.5 Duct Insulation offers: or other products, ■ Space-saving shaft alternative for air certifications, code distribution and grease duct systems. compliance, installa- ■ 2 hour fire-rated duct protection; zero tion instructions or drawings, contact clearance to combustibles. Unifrax Corporate headquarters USA ■ Solutions for building design and complex at 716-278-3800. job configurations. ■ Thin, lightweight flexible blanket for faster, easier installation. www.unifrax.com ■ Offers both fire and insulation performance. PLENUM FIRE PROTECTION Steiner tunnel windows and cover Code-compliant Solution for Combustible Plenums Fire protection wrap systems can provide -
Grease Duct Enclosures Fire and Smoke Dampers in Grease Ducts
506.3.11 CHANGE TYPE: Modification CHANGE SUMMARY: The code specifically prohibits the installation of Grease Duct Enclosures fire and smoke dampers in grease ducts. 2015 CODE: 506.3.11 Grease Duct Enclosures. A commercial kitchen grease duct serving a Type I hood that penetrates a ceiling, wall, floor or any concealed spaces shall be enclosed from the point of penetration to the outlet terminal. In-line exhaust fans not located outdoors shall be enclosed as required for grease ducts. A duct shall penetrate exterior walls only at locations where unprotected openings are permitted by the International Building Code. The duct enclosure shall serve a single grease duct and shall not contain other ducts, piping or wiring systems. Duct enclosures shall be either a shaft enclosure in accordance with Section 506.3.11.1, a field-ap- plied enclosure assembly in accordance with 506.3.11.2 or a factory-built enclosure assembly in accordance with Section 506.3.11.3. Duct enclosures shall have a fire-resistance rating of not less than that of the assembly pen- etrated and not less than 1 hour. Fire dampers and smoke dampers shall not be installed in grease ducts. Duct enclosures shall be as prescribed by Section 506.3.11.1, 506.3.11.2 or 506.3.11.3. 506.3.11.4 Duct enclosure not required. This excerpt is taken from Exception: A duct enclosure shall not be required for a grease duct Significant Changes to the that penetrates only a non-fire-resistance-rated roof/ceiling assembly. International Plumbing/ CHANGE SIGNIFICANCE: It has long been understood that fire and smoke dampers are not compatible with grease ducts, and the duct en- Mechanical/ closure requirements clearly account for the lack of such dampers where Fuel Gas the ducts penetrate walls, floors and ceilings. -
Hydronic Air Handler for 5100 Series Comfort Plus Furnaces
Hydronic Air Handler for 5100 Series Comfort Plus Furnaces FEATURES: GENERAL: Heavy duty The Steffes Air Handler is insulation an optional device provides designed to interface with maximum the Comfort Plus sound control Hydronic (5100 Series) for quiet furnace to allow it to operation provide forced air heating Durable design as a stand alone furnace with urethane or as a supplement to exterior paint other ducted heating finish systems such as a heat Built-in, pump. When used with a automatic static heat pump, it allows the heat recovery Comfort Plus Hydronic system furnace to serve as the back-up heat source and 5-Year Limited provide comfort Manufacturer’s modulation. Heat pumps Warranty can be operated to much lower temperatures allowing for full utilization of their efficiency while optimizing system performance. A duct sensor constantly monitors outlet air temperature and modulates the precise amount of stored off-peak heat needed to eliminate uncomfortable discharge air temperatures typically associated with heat pump systems during cool outdoor temperatures. The air handler also directs the heat lost statically through the furnace’s outer panels into the ductwork for delivery to the living space (automatic static heat recovery). The internal controls of the Comfort Plus Hydronic furnace automatically regulate the operation of the air handler. OPERATION: A heat call from the room thermostat will energize the pump to circulate a water/glycol solution through the Comfort Plus Hydronic’s heat exchanger where it is heated to the appropriate temperature. This heated water solution is then circulated through the air handler’s water coil. -
Duct Liner Insulation
Duct Liner Insulation Product Performance for Lining HVAC Ducts ABOUT K-FLEX USA K-FLEX USA IS A LEADING MANUFACTURER In April 2012, K-FLEX USA was awarded of closed cell flexible elastomeric foam with ISO 9001:2008 certification by FM insulation products for mechanical Approvals. The independent certification piping, air handling units and vessels. demonstrates the company’s commitment to quality. Designed for ease of installation and reliable performance, K-FLEX® products K-FLEX products have proven performance provide excellent thermal and acoustical in the Plumbing, HVAC/R, Commercial/ performance, including inherent Industrial, Marine, Oil & Gas, Acoustic resistance to moisture intrusion. and OEM Markets. Youngsville, NC Headquarters K-FLEX USA prides itself on being As a member of the IK Insulation Group, responsive to the market, providing K-Flex USA delivers state-of-the-art levels dependable service to customers of technical knowledge and customer throughout North America, bringing an support to the global mechanical innovative approach to product offerings, insulation market. and having products that are 3rd party tested and certified. ISO 9001 CERTIFIED COMPANY HISTORY 2001 Nomaco Insulation and 1989 L’Isolante K-FLEX joined to 2004 1965 L’Isolante K-FLEX was formed. form Nomaco K-FLEX (NKF). NKF acquired RBX’s mechanical insulation Rubatex was formed. business. 1975 1999 2002 2008 Halstead was formed and INSUL-TUBE® Rubatex acquired NKF entered into a Sales & L’Isolante K-FLEX and became a well-known product brand. Halstead -
READ ONLY Trane Variable Refrigerant Flow Systems a Completely Customizable Solution for Efficient, Room-By-Room Comfort, Where and When You Need It
Trane Variable Refrigerant Flow Systems Room-by-Room Customizable Comfort READ ONLY Trane Variable Refrigerant Flow Systems A completely customizable solution for efficient, room-by-room comfort, where and when you need it. More Heating and Cooling Options Trane has a tradition of quality The addition of Trane Variable Refrigerant Flow (VRF) lasting more than a century. systems to our full line of HVAC solutions affirms the Trane commitment to giving our customers the options Over one hundred years they need to precisely meet their heating and cooling ago, Reuben and James needs. Trane VRF systems can be the perfect solution Trane made the decision for many structures, and may be the perfect heating to stand out from the and cooling solution for these situations: crowd and build a comfort • Historic buildings where installing duct work can be system like no other, using difficult or impossible uncompromising quality, • Large commercial buildings like schools, medical innovation and reliability. offices and retail stores Today, their legacy is found in everything Trane makes, from • Multi-tenant buildings, retail spaces and strip malls where heating and cooling needs vary from room to our premium materials to our room and space to space industry-leading technology to our extensive product • New construction where the efficiency of a ductless testing under the harshest system and zone control is desired Trane Storefront La Crosse, Wisconsin 1891 conditions. When you buy • Applications where simultaneous heating and Courtesy of the La Crosse (Wisconsin) a Trane, you’re buying a cooling from a single unit is required to provide Public Library Archives commitment from us, to you.