VAV Guidelines TABLE OF CONTENTS Preface........................................................................................................................................ vi Overview ..................................................................................................................................... 1 Audience and Objectives.......................................................................................... 1 Key Recommendations ............................................................................................ 2 Energy Impacts.......................................................................................................... 4 Design Guide Organization ..................................................................................... 6 Introduction................................................................................................................................ 9 Objective ...................................................................................................................... 9 Role of the Designer................................................................................................10 Market Share............................................................................................................11 Integrated Design Issues.......................................................................................14 The Role of Simulation in Design ........................................................................16 HVAC System Selection..........................................................................................22 Location and Size of Airshafts..............................................................................28 Return Air System...................................................................................................30 Auxiliary Loads........................................................................................................33 Design Airside Supply Temperature ..................................................................34 Code Ventilation Requirements ...........................................................................36 Determining Internal Loads..................................................................................37 Simulation and Performance Targets................................................................47 Zone Issues...............................................................................................................................50 Thermal Comfort .....................................................................................................50 Zoning and Thermostats .......................................................................................52 Demand Control Ventilation (DCV).......................................................................53 Occupancy Controls ................................................................................................57 Window Switches....................................................................................................57 Design of Conference Rooms................................................................................58 VAV box selection....................................................................................................................60 VAV Box Selection Summary................................................................................60 VAV Reheat Box Control.........................................................................................61 Minimum Airflow Setpoints..................................................................................67 Sizing VAV Reheat Boxes ......................................................................................75 Other Box Types.......................................................................................................81 Other Issues..............................................................................................................88 Duct Design...............................................................................................................................93 General Guidelines..................................................................................................93 Supply Duct Sizing ..................................................................................................99 XiX Return Air System Sizing....................................................................................104 Fan Outlet Conditions ...........................................................................................105 Noise Control..........................................................................................................106 Supply Air Temperature Control.......................................................................................110 Optimal Supply Air Temperature......................................................................110 Recommended Sequence of Operation.............................................................112 System Design Issues..........................................................................................113 Code Requirements ..............................................................................................114 Fan Type, Size and Control.................................................................................................115 Fan Selection Criteria ..........................................................................................115 Visualizing Fan Performance ............................................................................119 Fan Selection Case Studies.................................................................................126 Comparing Manufacturers .................................................................................146 Fan Control .............................................................................................................147 Conclusions............................................................................................................161 Coils and Filters ....................................................................................................................163 Construction Filters..............................................................................................163 Pre-Filters...............................................................................................................163 Final Filter Selection ............................................................................................163 Filter Area...............................................................................................................164 Extended Surface Area Filters ...........................................................................164 Monitoring Filters.................................................................................................164 Coil Selection..........................................................................................................165 Coil Bypass.............................................................................................................167 Outside Air/Return Air/Exhaust Air Control.................................................................168 Control of Minimum Outdoor Air for VAV Systems.......................................168 Isolation Zones ......................................................................................................176 Design of Airside Economizer Systems...........................................................176 Economizer Temperature Control ....................................................................181 Economizer High-Limit Switches......................................................................182 Appendix 1 – Monitoring Sites...........................................................................................184 Site 1 ........................................................................................................................184 Site 2 ........................................................................................................................186 Site 3 ........................................................................................................................188 Site 4 ........................................................................................................................189 Site 5 ........................................................................................................................190 Appendix 2 – Measured Fan Performance......................................................................192 Energy Benchmark Data .....................................................................................192 xiiX Appendix 3 – Airflow in the Real World.......................................................................... 196 Interior Zone Airflow........................................................................................... 196 Perimeter Zone Airflow ...................................................................................... 198 System Level Airflow........................................................................................... 200 Appendix 4 – Cooling Loads in the Real World.............................................................. 203 Appendix 5 – DOE-2 Fan Curves....................................................................................... 206 Appendix
Recommended publications
  • Document Title
    Yale University Design Standards 15815 CONTENTS A. Summary Metal Ducts B. System Design and Performance Requirements C. Materials This document provides design standards D. Installation Guidelines only, and is not intended for use, in whole E. Quality Control—Ductwork Field Tests or in part, as a specification. Do not copy F. Cleaning and Adjusting this information verbatim in specifications or in notes on drawings. Refer questions and comments regarding the content and use of this document to the Yale University Project Manager. A. Summary This section contains design criteria for rectangular and round metal ductwork, duct liners, and hangers for supply, return, and exhaust systems. B. System Design and Performance Requirements 1. Keep the ductwork layout simple. Use short, direct runs where ever possible, and conserve ceiling space. 2. All return/exhaust air must be ducted. The use of ceiling plenums for return/exhaust air is prohibited. 3. Perchloric acid fume exhaust ductwork must be individually ducted without connection to other exhausts. 4. Fume hoods and contaminated or hazardous areas must be exhausted by a system of ducts entirely separate from all other exhaust systems. The location of area exhausts should be carefully coordinated with reference to remoteness from supply air outlets, doors, and windows. Animal areas and toilet rooms shall have separate exhausts. See Section 00705: General HVAC Design Conditions. 5. Wherever possible, exhaust ducts carrying noxious or corrosive fumes must be under negative pressure; connect them on the suction side of the fan. 6. Review appropriate SMANCA sections (laboratory) when designing duct distribution systems. Subdivision 15800: Air Distribution 1 Revision 2, 05/13 Yale University Design Standards Section 15815: Metal Ducts 7.
    [Show full text]
  • End of Section 23 31 14
    University of Houston Master Construction Specifications Insert Project Name SECTION 23 31 14 - DUCTWORK ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01 00, "Mechanical General Provisions", govern this Section. 1.2 DESCRIPTION OF WORK: A. Work Included: Provide ductwork accessories as shown on the Drawings, specified and required. B. Types: The types of ductwork accessories required for the project include, but are not limited to: 1. Flexible connections. 2. Direction and volume control dampers. 3. Fire dampers. 4. Fire/smoke dampers. 5. Smoke Dampers. 6. Radiation dampers. 7. Flashing and counterflashing. 8. Turning vanes. 9. Duct access doors and inspection plates. 10. Test openings. 11. Screens. 12. Miscellaneous ductwork materials. 1.3 QUALITY ASSURANCE: A. SMACNA Compliance: Comply with applicable portions of Sheet Metal and Air Conditioning Contractors' National Association (SMACNA) "HVAC Duct Construction Standards", current edition. B. ASHRAE Standards: Comply with American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE) recommendations pertaining to construction of ductwork accessories, except as otherwise indicated. C. Certification: Fire, fire/smoke and smoke dampers shall be UL-listed, FM-approved and comply with applicable building code requirements. D. Manufacturers: Provide products complying with the specifications and produced by one of the following: 1. American Foundry. 2. Air Balance Inc. 3. Duro-Dyne. 4. Elgin Sheet Metal Products. 5. Nailor Industries. 6. Prefco. 7. Ruskin. 8. Tuttle and Bailey. 9. United Sheet Metal. 10. Vent-Fabrics, Inc. 11. Ventlok. 12. Young Regulator Co. 1.4 SUBMITTALS: AE Project Number: Ductwork Accessories 23 31 14 – 1 Revision Date: 1/29/2018 University of Houston Master Construction Specifications Insert Project Name A.
    [Show full text]
  • HVAC Controls (DDC/EMS/BAS) Evaluation Protocol
    Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures Created as part of subcontract with period of performance September 2011 – December 2014 Jeff Romberger SBW Consulting, Inc. Bellevue, Washington NREL Technical Monitor: Charles Kurnik NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Operated by the Alliance for Sustainable Energy, LLC This report is available at no cost from the National Renewable Energy Laboratory (NREL) at www.nrel.gov/publications. Subcontract Report NREL/SR-7A40-63167 November 2014 Contract No. DE-AC36-08GO28308 Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures Created as part of subcontract with period of performance September 2011 – December 2014 Jeff Romberger SBW Consulting, Inc. Bellevue, Washington NREL Technical Monitor: Charles Kurnik Prepared under Subcontract No. LGJ-1-11965-01 NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Operated by the Alliance for Sustainable Energy, LLC This report is available at no cost from the National Renewable Energy Laboratory (NREL) at www.nrel.gov/publications. National Renewable Energy Laboratory Subcontract Report 15013 Denver West Parkway NREL/SR-7A40-63167 Golden, CO 80401 November 2014 303-275-3000 • www.nrel.gov Contract No. DE-AC36-08GO28308 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights.
    [Show full text]
  • Gaylord Clearair Ventilator
    NATIONAL BUREAU OF STANDARDS REPORT 3171 GAYLORD CLEARAIR VENTILATOR by Carl W. Coblentz Paul R. Achenbach Report to Bureau of Ships Department of the Navy U. S. DEPARTMENT OF COMMERCE NATIONAL BUREAU OF STANDARDS U. S. DEPARTMENT OF COMMERCE Sinclair Weeks, Secretary NATIONAL BUREAU OF STANDARDS A. V. Astin, Director THE NATIONAL BUREAU OF STANDARDS The scope of activities of the National Bureau of Standards is suggested in the following listing of the divisions and sections engaged in technical work. In general, each section is engaged in special- ized research, development, and engineering in the field indicated by its title. A brief description of the activities, and of the resultant reports and publications, appears on the inside of the back cover of this report. Electricity. Resistance and Reactance Measurements. Electrical Instruments. Magnetic Measurements. Electrochemistry. Optics and Metrology. Photometry and Colorimetry. Optical Instruments. Photographic Technology. Length. Engineering Metrology. Heat and Power. Temperature Measurements. Thermodynamics. Cryogenic Physics. Engines and Lubrication. Engine Fuels. Cryogenic Engineering. Atomic and Radiation Physics. Spectroscopy. Radiometry. Mass Spectrometry. Solid State Physics. Electron Physics. Atomic Physics. Neutron Measurements. Infrared Spectros- copy. Nuclear Physics. Radioactivity. X-Ray. Betatron. Nucleonic Instrumentation. Radio- logical Equipment. Atomic Energy Commission Radiation Instruments Branch. Chemistry. Organic Coatings. Surface Chemistry. Organic Chemistry. Analytical Chemistry. Inorganic Chemistry. Electrodeposition. Gas Chemistry. Physical Chemistry. Thermochemistry. Spectrochemistry. Pure Substances. Mechanics. Sound. Mechanical Instruments. Fluid Mechanics. Engineering Mechanics. Mass and Scale. Capacity, Density, and Fluid Meters. Combustion Control. Organic and Fibrous Materials. Rubber. Textiles. Paper. Leather. Testing and Specifica- tions. Polymer Structure. Organic Plastics. Dental Research. Metallurgy. Thermal Metallurgy. Chemical Metallurgy.
    [Show full text]
  • CHAVEZ-DISSERTATION-2016.Pdf
    Copyright by Kyle Feliciano Chavez 2016 The Dissertation Committee for Kyle Feliciano Chavez certifies that this is the approved version of the following dissertation: Variable Incidence Angle Film Cooling Experiments on a Scaled Up Turbine Airfoil Model Committee: David G. Bogard, Supervisor Frederick Todd Davidson Atul Kohli Ofodike A. Ezekoye Michael E. Webber Variable Incidence Angle Film Cooling Experiments on a Scaled Up Turbine Airfoil Model by Kyle Feliciano Chavez, B.S.; M.S. Dissertation Presented to the Faculty of the Graduate School of The University of Texas at Austin in Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy The University of Texas at Austin May 2016 Dedication This document is dedicated to my family. Dad, you have always been so encouraging, helpful, and levelheaded. If not for all of your help and encouragement, I’m not sure I’d be where I’m at today. To my brother, I’m so happy for the years we spent growing up together. They are some of my fondest memories and I’ll never forget them. Mom, if you were still here today, you’d be so proud. I think of you all constantly, and I love you all. Acknowledgements I would like to first and foremost thank Dr. Bogard, who has supported and taught me so much along the way. Your dedication to your field of research is an inspiration to me, and you’ve helped shape me in to the engineer I am today. You also taught me how great it is to be “mighty fine” all the time, and that’s priceless in and of itself.
    [Show full text]
  • Smart Buildings: Using Smart Technology to Save Energy in Existing Buildings
    Smart Buildings: Using Smart Technology to Save Energy in Existing Buildings Jennifer King and Christopher Perry February 2017 Report A1701 © American Council for an Energy-Efficient Economy 529 14th Street NW, Suite 600, Washington, DC 20045 Phone: (202) 507-4000 • Twitter: @ACEEEDC Facebook.com/myACEEE • aceee.org SMART BUILDINGS © ACEEE Contents About the Authors ..............................................................................................................................iii Acknowledgments ..............................................................................................................................iii Executive Summary ........................................................................................................................... iv Introduction .......................................................................................................................................... 1 Methodology and Scope of This Study ............................................................................................ 1 Smart Building Technologies ............................................................................................................. 3 HVAC Systems ......................................................................................................................... 4 Plug Loads ................................................................................................................................. 9 Lighting ..................................................................................................................................
    [Show full text]
  • Hvac Controls Introduction
    Invensys Building Systems ON-LINE VERSION HVAC CONTROLS INTRODUCTION Pop-up Definitions in this Online Document • Terms that are blue, italic, and underlined, are provided with pop-up definitions, which can be accessed through blue “question mark” symbols located in the outside margin. • To open a definition, simply double-click the “question mark” symbol that is most in line with the term. • To close the definition, click the “close” box in the upper-left of the window. • These terms are also defined in the glossary of this document. Invensys Building Systems HVAC CONTROLS INTRODUCTION Printed in U.S.A. 3/01 F-26962 Copyright Notice The confidential information contained in this document is provided solely for use by Invensys Building Systems employees, licensees, and system owners, and is not to be released to, or reproduced for, anyone else. Neither is it to be used for unauthorized reproduction of an Invensys control system or any of its components. All specifications are nominal and may change as design improvements occur. Invensys Building Systems shall not be liable for damages resulting from misapplication or misuse of its products. Invensys Building Systems 1354 Clifford Avenue (Zip 61111) P.O. Box 2940 Loves Park, IL 61132-2940 United States of America © Invensys Building Systems 2001 Invensys, PopTop, and DuraDrive are trademarks of Invensys plc and its subsidiaries and affiliates. ii Invensys Building Systems Table of Contents Preface........................................................................................................
    [Show full text]
  • Energy Saving of Central Air-Conditioning and Control System Caseb Study: Nanchang Hongkelong Supermarket
    Energy Saving of Central Air-Conditioning and Control System Caseb Study: Nanchang Hongkelong Supermarket Thesis Yizhou He Degree Programme in Industrial Management Accepted ___.___._____ __________________________________ SAVONIA UNIVERSITY OF APPLIED SCIENCES, BUSINESS AND ENGINEERING, VARKAUS Degree Programme Industrial Engineering and Management Author He Yizhou Title of Project Energy saving of central air-conditioning and control system Case study: Nanchang Hongkelong Supermarket Type of Project Date Pages Final Project 13/10/2010 6 2+8 Academic Supervisor Company Supervisor Company Harri Heikura Zheng Jun HKLS Abstract In China, with the rapid development of economiy, the resources are consumed very seriously. Compared with the developed countries, China’s energy consumption for unit GDP production is more than 6 to 10 times and the energy consumption for unit product production is 50% higher than in the developed countries. Therefore, China is increasing emphasis on energy conservation and is also increasing the awareness of energy saving and environmental protection. In energy saving measures, the one that reduces energy consumption of the central air conditioning is very important. Because in industrial and commercial buildings, central air conditioning system is a very important part of infrastructure and it is widely used. It takes a large proportion in industrial production and the total daily energy consumption of buildings. In industry, central air-conditioning energy consumption accounts for over 40% of the total energy consumption. In this thesis, the problem and the cause of the problem were found according to the research of the specific practical problem of the traditional energy saving system. Based on the theory of intelligent building management system (IBMS) and energy-saving central air-conditioning inverter, a means of vector control can be adopted to achieve the integrated use of the technology and a solution to improve the Central Air Conditioner equipment and improve HVAC energy saving control system can be found.
    [Show full text]
  • Guideline on Through Penetration Firestopping
    GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING SECOND EDITION – AUGUST 2007 SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 www.smacna.org GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING Copyright © SMACNA 2007 All Rights Reserved by SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 Printed in the U.S.A. FIRST EDITION – NOVEMBER 1996 SECOND EDITION – AUGUST 2007 Except as allowed in the Notice to Users and in certain licensing contracts, no part of this book may be reproduced, stored in a retrievable system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of the publisher. FOREWORD This technical guide was prepared in response to increasing concerns over the requirements for through-penetration firestopping as mandated by codes, specified by system designers, and required by code officials and/or other authorities having jurisdiction. The language in the model codes, the definitions used, and the expectations of local code authorities varies widely among the model codes and has caused confusion in the building construction industry. Contractors are often forced to bear the brunt of inadequate or confusing specifications, misunderstandings of code requirements, and lack of adequate plan review prior to construction. This guide contains descriptions, illustrations, definitions, recommendations on industry practices, designations of responsibility, references to other documents and guidance on plan and specification requirements. It is intended to be a generic educational tool for use by all parties to the construction process. Firestopping Guideline • Second Edition iii FIRE AND SMOKE CONTROL COMMITTEE Phillip E.
    [Show full text]
  • Intelligent Thermal Control Method for Small-Size Air Conditioning System
    Intelligent Thermal Control Method for Small-Size Air Conditioning System Hung-Wen Lin1, Min-Der Wu1, Guan-Wen Chen1 and Ying Xuan Tan2 1Green Energy and Research Laboratories, Industrial Technology Research Institute, Hsinchu, Taiwan 2Department of Mechanical Engineering, University of Malaya, Kuala Lumpur, Malaysia Keywords: HVAC, Least Enthalpy Difference Theory, Energy Saving. Abstract: To decrease the energy consumption and maintaining the comfort of the area, a great deal of work has been done on HVAC control algorithms. A control system with the least enthalpy difference theory applied is proposed in this paper. By using the indoor air temperature and relative humidity as the feedback of the control system, the temperature set for the air conditioner is able to satisfy the indoor thermal comfort. The simulation and experimental results of this controller have shown positive energy saving while maintaining indoor thermal comfort. 1 INTRODUCTION “Adaptive Algorithm” which requires an additional parameter which is the expected residence time of the Due to the significant increase of energy consumption occupants for each zone to be controlled (Dimitris, in buildings, energy saving strategies have become Evangelos, John and Odysseus, 2014). An the first priority in energy policies in most countries occupancy-based feedback control algorithm for around the world. In 2006, United States of America variable-air volume HVAC systems that is applicable had used about 35% of the total energy for HVAC to the under-actuated case in which multiple rooms systems (US EIA, 2017). About 50% of the world’s share the same HVAC equipment was implemented. total electrical energy is consumed by HVAC systems Despite the inability to condition rooms (Fagan, Refai and Tachwali, 2007).
    [Show full text]
  • 23.31.00 Ductwork
    UNIVERSITY OF PENNSYLVANIA Design Standards Revision July 2019 SECTION 233100 – DUCTWORK 1.0 Acoustical duct lining in any part of the duct system is prohibited. All ductwork requiring insulation shall be externally insulated (Refer to the Sheet Metal Ductwork Insulation Schedule in Section 230700 for insulation types and thickness). Double walled ducts consisting of an outer wall of galvanized sheet metal, an inner wall of perforated galvanized sheet metal with insulation sandwiched between the layers is permitted. 2.0 All ductwork shall be designed, constructed, supported and sealed in accordance with SMACNA HVAC Duct Construction Standards and pressure classifications. When the ductwork pressure classification of these standards is exceeded, construct ductwork in accordance with SMACNA Round and Rectangular Industrial Duct Construction Standards. The following preferences or modifications to the Standards shall be specified: A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows. B. All square elbows must be constructed with single thickness turning vanes, Runner Type 2 as shown in Figures 4-3 and 4-4 of SMACNA Duct Construction Standards - Metal and Flexible. Where a rectangular duct changes in size at a square-throat elbow fitting, use single thickness turning vanes with trailing edge extensions aligned with the sides of the duct. C. Air extractors and splitter dampers are not permitted. D. Transitions and offsets shall follow Figure 4-7 of SMACNA HVAC Duct Construction Standards - Metal and Flexible, except that sides of transitions shall slope a maximum of 15 degrees. E. Minimum duct gauge shall be 22 for ducts up through 43", 20 gauge up through 60" and 18 gauge above 60".
    [Show full text]
  • Grease Duct Enclosures Fire and Smoke Dampers in Grease Ducts
    506.3.11 CHANGE TYPE: Modification CHANGE SUMMARY: The code specifically prohibits the installation of Grease Duct Enclosures fire and smoke dampers in grease ducts. 2015 CODE: 506.3.11 Grease Duct Enclosures. A commercial kitchen grease duct serving a Type I hood that penetrates a ceiling, wall, floor or any concealed spaces shall be enclosed from the point of penetration to the outlet terminal. In-line exhaust fans not located outdoors shall be enclosed as required for grease ducts. A duct shall penetrate exterior walls only at locations where unprotected openings are permitted by the International Building Code. The duct enclosure shall serve a single grease duct and shall not contain other ducts, piping or wiring systems. Duct enclosures shall be either a shaft enclosure in accordance with Section 506.3.11.1, a field-ap- plied enclosure assembly in accordance with 506.3.11.2 or a factory-built enclosure assembly in accordance with Section 506.3.11.3. Duct enclosures shall have a fire-resistance rating of not less than that of the assembly pen- etrated and not less than 1 hour. Fire dampers and smoke dampers shall not be installed in grease ducts. Duct enclosures shall be as prescribed by Section 506.3.11.1, 506.3.11.2 or 506.3.11.3. 506.3.11.4 Duct enclosure not required. This excerpt is taken from Exception: A duct enclosure shall not be required for a grease duct Significant Changes to the that penetrates only a non-fire-resistance-rated roof/ceiling assembly. International Plumbing/ CHANGE SIGNIFICANCE: It has long been understood that fire and smoke dampers are not compatible with grease ducts, and the duct en- Mechanical/ closure requirements clearly account for the lack of such dampers where Fuel Gas the ducts penetrate walls, floors and ceilings.
    [Show full text]