The Complete Product Range – 2021 Small Devices, Big Impact

Total Page:16

File Type:pdf, Size:1020Kb

The Complete Product Range – 2021 Small Devices, Big Impact Small devices, big impact. The complete product range – 2021 Small devices, big impact. Comfort Energy effi ciency Safety Installation Maintenance Belimo is a world market leader in the development, production and sales of actuator solutions for regulat- ing and controlling heating, ventilation and air conditioning systems. The company's core business includes actuators, control valves and sensors. Innovations redefi ning comfort Experience installation ease A precisely controlled, comfortable room environment Simple installation and quick commissioning save is essential for the well-being and productivity of people. time. Two exemplary features that signifi cantly reduce Belimo sensors, variable air volume (VAV) technology installation time are the unique, tool-free mountable and pressure-independent control valves are three protective housings for sensors and actuators as well examples that have a big impact on room comfort. as commissioning via smartphone. Belimo offers a comprehensive product range for this – also for retrofi t Energy effi ciency delivered applications. Fast delivery to the desired location is a The smart control of heating, cooling, and ventilation matter of course at Belimo. systems has a major impact on the energy effi ciency of buildings. Belimo sets standards for energy-effi cient Long service life paired with solutions − such as power-saving actuators, air-bubble fi rst-class support tight ball valve technology and the Belimo Energy Valve™. Low maintenance outlay and professional service have a lasting effect on building performance. Belimo's Uncompromised safety devices are famous for their long lifetime and 5-year Safety actuators from Belimo save lives and help to warranty. In addition, our IoT (Internet of Things) minimise damage to buildings and tangible assets. They product range enables real-time monitoring and full are highly reliable and have been specially designed transparency to achieve optimal building performance. for fi re dampers and smoke control dampers. An additional product range of fail-safe actuators and fast running actuators prevents hazardous situations, thereby increasing operating safety. Everything under one roof. 3 13 8 13 1 10 8 6 13 1 13 10 12 10 9 9 6 4 4 3 2 13 13 13 2 8 10 9 5 4 4 13 13 7 5 13 7 5 10 10 14 8 9 9 10 Illustration example Air Water Sensors 1 Air damper actuators 5 Zone valves 10 Temperature sensors 2 Fire damper actuators 6 Pressure-independent characterised control valves 11 Humidity sensors 3 Smoke control damper actuators 7 Characterised control valves 12 Air quality sensors 4 VAV-Compact / VAV-Universal 8 Globe valves 13 Pressure sensors 9 Open/close and changeover butterfl y valves 14 Flow sensors Fan Air heater Air cooler Boiler Pump Variable speed Heat Chiller / heat Cold water Transfer pump exchanger pump reservoir station Actuator, valve and sensor solutions. Ventilation applications Air treatment, distribution, control and feedback The world's most comprehensive range of electrical actuator solutions for air dampers of up to 8 m2 includes rotary and linear actuators with a wide range of motorisation levels and actuating times. The actuators cover almost all motorisation requirements for the control of air flows in air-conditioning plants, from treatment and distribution to feedback and retreatment. The product range also includes special actuators for indoor and outdoor use in harsh ambient conditions. As the perfect complement to the actuators, Belimo offers a comprehensive product range of sensors for measuring air temperature, humidity and quality. Differential pressure sensors guarantee an accurate filter monitoring to optimally plan the service calls in advance. Water applications Efficient operation of heating and cooling circuits In addition to motorised butterfly valves and globe valves, Belimo supplies unique, air-bubble tight characterised control valves for the precise control of heating and cooling circuits without energy loss. Pressure-independent characterised control valves always ensure the correct amount of water thanks to permanent dynamic balancing, even if there are differential pressure changes and during partial load operation. The forward-looking Belimo Energy Valve™ with integrated logic allows energy flows to be mo- nitored and optimised. The integrated delta T manager ensures that the differential temperature does not fall below defined values and that the heat exchanger is always run in the energy-efficient range. Tight-sealing valves of the Belimo ZoneTight™ product range are the ideal solution for energy-saving, unproblematic room and zone control in tight spaces. Retrofit applications Giving new verve to old systems For renovations in existing construction and replacements for older actuators on air dampers, globe valves and rotary valves, Belimo supplies a comprehensive product range of special Retrofit motorisation solutions. Their parameters can be set precisely on site to the prevailing requirements. Retrofit globe and rotary actuators can be mounted practically on all common valve makes with only a few steps. Handy VAV-Retrofit kits with controllers, actuators and differential pressure sensors are available for replacing defective or pneumatic VAV devices. To easily determine the right replacement actuators or sensors, Belimo has developed a Retrofit tool which determines the suitable actuator using different parameters. Open the Retrofit tool: The tool can be used everywhere – on site or in the office. Now also with optical character recognition (OCR). The software recognises the actuator labelling and connects the relevant text modules with the RetroFIT database. For every fi eld of application. Safety solutions Protecting life and material assets from fi re and smoke Fires represent the greatest potential threat to people and tangible assets in buildings. Effi cient fi re protection saves lives in times of danger, helps minimise property damage and secures the continued operation of com- panies. The best protection against the spread of fi re and smoke through the ductwork is provided by compartmentalisation using motorised fi re dampers. Smoke control systems with motorised smoke control dampers ensure smoke-free escape and rescue routes. System protection Avoiding damage in the event of interruptions to operation Fail-safe actuators protect valuable systems from damage caused by ice, water and steam. Particularly in the event of a power supply voltage failure, this actuator product range moves the dampers to the predefi ned fail-safe position. Depending on the actuator, short power failures can be bridged for up to 10 seconds and the fail-safe positions can be individually defi ned. Unnecessary failures and convenience impairments are thereby prevented. Bus and system integration Monitoring and controlling systems from a central location Belimo actuators can be easily integrated into intelligent building manage- ment systems. Actuators with an integrated BACnet, Modbus and KNX interface are available for direct connections. MP actuators can be used to combine up to eight different control elements into one MP-Bus section and connect to virtually any supervisory system with greatly reduced wiring costs. Different adjustment and service tools as well as the Belimo Cloud make the installation, monitoring and optimisation easier. IoT actuators communicate via Ethernet and synchronise directly with the Belimo Cloud. Belimo Cloud Room and system solutions Ensuring individual comfort and saving energy Used in offi ces, public buildings, production halls, commercial premises or sensitive operating areas, volumetric fl ow controllers, actuators and sensors ensure an optimum room climate while consuming minimal levels of energy. They can be used as VAV-Compact or VAV-Universal devices. The latter ensure safe conditioning in room pressure applications. Special, compact VAV control units are available for distribution boxes used in controlled apartment ventilation. Ventilation applications. Rotary actuators without fail-safe Product range Types/performance classes Specifi cations Applications Standard actuators: • With integrated auxiliary switch Motorisation of air dampers • TMC (2 Nm) or potentiometer without fail-safe up to 8 m2 • LM (5 Nm) • Identical accessories for all • NM (10 Nm) types • SM (20 Nm) • Connection: Cable (IP54) or • GM (40 Nm) terminals (IP20 or IP54) Compact actuators: • Mechanical angle of rotation Motorisation of air dampers • CM (2 Nm) limitation 0...287.5° or endless without fail-safe up to 0.4 m2 in • CM..G (2 Nm, IP66) rotation apartment ventilation systems, • Magnetic gearing latch underfl oor air-conditioning • The slimmest actuator of its type equipment, decentralised sill • Simple mounting ventilation units, etc. Simple compact actuator: • Plug-in actuator Motorisation of air dampers • UM (1 Nm, IP20) 1) • Mechanical angle of rotation without fail-safe up to 0.2 m2 in limitation 0...287.5° or endless apartment ventilation systems, rotation (for form-fi t variant) decentralised distribution systems • Fast running time of 22 s / 90° and air outlets Compact actuator with • Damper diameter 100, 125, 150 Motorisation of round air dampers integrated damper blade: and 160 mm without fail-safe up to DN 160 in • CM..D (2 Nm) • Air tight in accordance with DIN apartment ventilation systems, air EN 1751, Classes 3 and 2 distribution systems, after-fl ows, • Sound power level ≤ 35 dB(A) facade units, etc. • Useable up to 1000 Pa max. • Running time 58 s / 70° Rotary actuator with high torque:
Recommended publications
  • Gaylord Clearair Ventilator
    NATIONAL BUREAU OF STANDARDS REPORT 3171 GAYLORD CLEARAIR VENTILATOR by Carl W. Coblentz Paul R. Achenbach Report to Bureau of Ships Department of the Navy U. S. DEPARTMENT OF COMMERCE NATIONAL BUREAU OF STANDARDS U. S. DEPARTMENT OF COMMERCE Sinclair Weeks, Secretary NATIONAL BUREAU OF STANDARDS A. V. Astin, Director THE NATIONAL BUREAU OF STANDARDS The scope of activities of the National Bureau of Standards is suggested in the following listing of the divisions and sections engaged in technical work. In general, each section is engaged in special- ized research, development, and engineering in the field indicated by its title. A brief description of the activities, and of the resultant reports and publications, appears on the inside of the back cover of this report. Electricity. Resistance and Reactance Measurements. Electrical Instruments. Magnetic Measurements. Electrochemistry. Optics and Metrology. Photometry and Colorimetry. Optical Instruments. Photographic Technology. Length. Engineering Metrology. Heat and Power. Temperature Measurements. Thermodynamics. Cryogenic Physics. Engines and Lubrication. Engine Fuels. Cryogenic Engineering. Atomic and Radiation Physics. Spectroscopy. Radiometry. Mass Spectrometry. Solid State Physics. Electron Physics. Atomic Physics. Neutron Measurements. Infrared Spectros- copy. Nuclear Physics. Radioactivity. X-Ray. Betatron. Nucleonic Instrumentation. Radio- logical Equipment. Atomic Energy Commission Radiation Instruments Branch. Chemistry. Organic Coatings. Surface Chemistry. Organic Chemistry. Analytical Chemistry. Inorganic Chemistry. Electrodeposition. Gas Chemistry. Physical Chemistry. Thermochemistry. Spectrochemistry. Pure Substances. Mechanics. Sound. Mechanical Instruments. Fluid Mechanics. Engineering Mechanics. Mass and Scale. Capacity, Density, and Fluid Meters. Combustion Control. Organic and Fibrous Materials. Rubber. Textiles. Paper. Leather. Testing and Specifica- tions. Polymer Structure. Organic Plastics. Dental Research. Metallurgy. Thermal Metallurgy. Chemical Metallurgy.
    [Show full text]
  • Guideline on Through Penetration Firestopping
    GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING SECOND EDITION – AUGUST 2007 SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 www.smacna.org GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING Copyright © SMACNA 2007 All Rights Reserved by SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 Printed in the U.S.A. FIRST EDITION – NOVEMBER 1996 SECOND EDITION – AUGUST 2007 Except as allowed in the Notice to Users and in certain licensing contracts, no part of this book may be reproduced, stored in a retrievable system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of the publisher. FOREWORD This technical guide was prepared in response to increasing concerns over the requirements for through-penetration firestopping as mandated by codes, specified by system designers, and required by code officials and/or other authorities having jurisdiction. The language in the model codes, the definitions used, and the expectations of local code authorities varies widely among the model codes and has caused confusion in the building construction industry. Contractors are often forced to bear the brunt of inadequate or confusing specifications, misunderstandings of code requirements, and lack of adequate plan review prior to construction. This guide contains descriptions, illustrations, definitions, recommendations on industry practices, designations of responsibility, references to other documents and guidance on plan and specification requirements. It is intended to be a generic educational tool for use by all parties to the construction process. Firestopping Guideline • Second Edition iii FIRE AND SMOKE CONTROL COMMITTEE Phillip E.
    [Show full text]
  • Grease Duct Enclosures Fire and Smoke Dampers in Grease Ducts
    506.3.11 CHANGE TYPE: Modification CHANGE SUMMARY: The code specifically prohibits the installation of Grease Duct Enclosures fire and smoke dampers in grease ducts. 2015 CODE: 506.3.11 Grease Duct Enclosures. A commercial kitchen grease duct serving a Type I hood that penetrates a ceiling, wall, floor or any concealed spaces shall be enclosed from the point of penetration to the outlet terminal. In-line exhaust fans not located outdoors shall be enclosed as required for grease ducts. A duct shall penetrate exterior walls only at locations where unprotected openings are permitted by the International Building Code. The duct enclosure shall serve a single grease duct and shall not contain other ducts, piping or wiring systems. Duct enclosures shall be either a shaft enclosure in accordance with Section 506.3.11.1, a field-ap- plied enclosure assembly in accordance with 506.3.11.2 or a factory-built enclosure assembly in accordance with Section 506.3.11.3. Duct enclosures shall have a fire-resistance rating of not less than that of the assembly pen- etrated and not less than 1 hour. Fire dampers and smoke dampers shall not be installed in grease ducts. Duct enclosures shall be as prescribed by Section 506.3.11.1, 506.3.11.2 or 506.3.11.3. 506.3.11.4 Duct enclosure not required. This excerpt is taken from Exception: A duct enclosure shall not be required for a grease duct Significant Changes to the that penetrates only a non-fire-resistance-rated roof/ceiling assembly. International Plumbing/ CHANGE SIGNIFICANCE: It has long been understood that fire and smoke dampers are not compatible with grease ducts, and the duct en- Mechanical/ closure requirements clearly account for the lack of such dampers where Fuel Gas the ducts penetrate walls, floors and ceilings.
    [Show full text]
  • Life Safety Dampers Selection and Application Manual • Ceiling Radiation Dampers • Fire Dampers • Combination Fire Smoke Dampers • Smoke Dampers
    Life Safety Dampers Selection and Application Manual • Ceiling Radiation Dampers • Fire Dampers • Combination Fire Smoke Dampers • Smoke Dampers August 2016 1 Table of Contents HOW TO USE THIS MANUAL DAMPER APPLICATION 3 • Fire Damper Application • Smoke Damper Application • Combination Fire Smoke Damper Application • Corridor Ceiling Combination Fire Smoke Damper Application DAMPER SELECTION 5 • Selection Process • Key Points to Remember ACTUATOR SELECTION 7 • Selection Process • Actuator Mounting Options • Key Points to Remember SLEEVE REQUIREMENTS 9 • Sleeve Thickness • Sleeve Length • Key Points to Remember SPACE REQUIREMENTS FOR PROPER INSTALLATION 10 • Key Points to Remember DAMPER OPTIONS 11 • Control Options • Security Bar Options • Transition Options • Key Points to Remember INSTALLATION REQUIREMENTS 15 • Combination Fire Smoke Damper Installation • Smoke Damper Installation • Actuator Installation • Damper and Actuator Maintenance • Key Points to Remember SPECIAL INSTALLATION CASES 17 • Maximum Damper Size Limitations • Horizontal Fire Smoke Damper in a Non-Concrete Barrier • AMCA Mullion System • What if a Damper Cannot be Installed per the Manufacturer’s Installation Instructions? • What if a Damper Cannot be Installed in the Wall? • Steps to Take When an Unapproved Installation Must be Provided CEILING RADIATION DAMPERS 20 • Ceiling Radiation Damper Application • Key Points to Remember CODES AND STANDARDS 21 • Compliance with the Applicable Building Codes • The National Fire Protection Association • Code and Standard Making
    [Show full text]
  • Basis of Design
    UNIVERSITY OF WASHINGTON Mechanical Facilities Services Heating Ventilation and Air Conditioning Design Guide Ductwork and Duct Accessories Basis of Design This section applies to the design and installation of ductwork, air terminal boxes, air outlets and inlets, volume dampers, pressure relief dampers, smoke/fire dampers, and smoke/fire damper actuators. Design Criteria Select duct velocities to meet N.C. requirements of each occupied space. NC level requirements shall be identified in the Basis of Design narrative. Coordinate required NC levels with University Project Manager and users. Supply, Return and Non Fume Exhaust Ductwork Provide a 6-inch pressure rating for supply ductwork and plenums between the supply fan and the zone terminal boxes; for ductwork downstream of the terminal box, provide a 2-inch pressure rating. If pressure classes less than those given above are considered sufficient for a specific application, review with Engineering Services before specifying a lower rating. Use the ASHRAE Handbook of Fundamentals chapter on duct design to determine the allowable leakage rate (cfm/100 sq.ft.) at the specified test pressure for each type of ductwork on the project other than fume exhaust ductwork. Specify for each type of ductwork the duct pressure rating, the pressure to apply during the duct leakage test, and the allowable cfm/100 sq.ft. leakage rate at the test pressure. Minimize use of square elbows. Provide turning vanes in square elbows of supply ductwork. Do not use turning vanes in return or exhaust ductwork. To minimize noise levels in the space, specify balancing dampers in lieu of registers. Provide a balancing damper for each outlet and each inlet.
    [Show full text]
  • Data Sheets 1-45 January 2018 Page 1 of 20
    FM Global Property Loss Prevention Data Sheets 1-45 January 2018 Page 1 of 20 AIR CONDITIONING AND VENTILATING SYSTEMS Table of Contents Page 1.0 SCOPE ..................................................................................................................................................... 3 1.1 Changes ............................................................................................................................................ 3 1.2 Hazard .............................................................................................................................................. 3 2.0 LOSS PREVENTION RECOMMENDATIONS ....................................................................................... 3 2.1 Construction and Location ............................................................................................................... 3 2.1.1 Ducts ....................................................................................................................................... 3 2.1.2 Automatic Fire Doors and Fire Dampers ............................................................................... 5 2.1.3 Air Filters ................................................................................................................................ 7 2.1.4 Fans, Air Intakes, and Outlets ................................................................................................ 7 2.1.5 Design ...................................................................................................................................
    [Show full text]
  • Fire/Smoke Dampers
    Fire/Smoke Dampers Ontario Building Code 2020: New Provisions for Fire & Smoke Dampers Fire & Smoke Dampers • Fire Separation & Fire Compartments • Fire Dampers • Smoke Dampers • OBC 2020: Fire/Smoke Damper Requirements • OBC 2020: Fire/Smoke Dampers Waived • OBC 2020: Installation Requirements • Installation Example Fire Separation • Fire Separation is the method of protecting buildings from the spread of fire to adjoining rooms. • Fire Separation is required when the function of a room meets the criteria outlined in section 3.3 of the OBC, or in their respective governing standard. Fire Separation • Fire Separation is achieved by • Fire-rated Building Materials come separating a space with approved with different ratings, commonly materials listed to have a fire ranging from 20 minutes to 3 rating. hours. – Walls, Floors & Ceilings – Doors – Ducts & Penetrations Fire Compartments • Fire Compartments: an • Fire Compartments are required architectural method to protect when the function of a room meets adjacent spaces from flame & the criteria outlined in section 3.3 smoke migration. of the OBC, or in their respective governing standard. Fire Dampers • Fire Dampers: – Close automatically upon detection of heat to maintain fire separation – Driving mechanism is typically a fuseable link that melts when the minimum temperature is met – Low-Cost. Come in a variety of types Smoke Dampers • Smoke Dampers: – Close automatically upon detection of smoke to maintain fire separation – Electronically or pneumatically driven, controlled by smoke detectors and/or fire alarm systems – When activated, smoke dampers must meet CAN/ULC-S112.1 “Leakage Rated Dampers for use in Smoke-Controlled Systems” and conform to Class I, II, or III of that standard.
    [Show full text]
  • Fire Damper Installation, Operation & Maintenance
    FIRE DAMPER INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS R8218 UL/ULC File: R8218 New York BSA/MEA Listing: 79-03-M California State Fire Marshall Listing: 3225-1721:0102 The following installation instructions are UL approved to be used with the following NCA Models: FD, FD-SL, FD-N, FD-USL, FD-MB-3V, FD-MB-AF, FD-3V-SB, FDD, FDD-SL, FDD-MB-3V, and FDD-MB- AF. Installation Supplements: - Installing Fire and Combination Fire/Smoke Dampers in a Shaft Wall - Framing Requirements for Wood or Steel Stud Walls Application & General Notes: - UL Approved Breakaway Duct Connections - Optional Sealing of Dampers in Fire and Smoke These installation instructions apply to Fire Dampers of the stat- Rated Walls or Floors ic, dynamic, curtain-style, single and multi-blade types mounted - Fabrication and Installation of Support Mullions in the plane of a UL* approved fire partition. For dampers needed - Field Modification of Factory Supplied Sleeves to be installed outside the plane of a UL approved wall or floor, - Security Bars for Fire and Fire/Smoke Dampers refer to the Out of Wall Fire and Fire/Smoke Damper IOM. The - Installing Fire and Fire/Smoke Dampers in Concrete dampers are designed for operation in the vertical or horizontal Floor with Steel Deck orientation with blades running horizontal. Safety Warning: Other Installation References: - Out-of-Wall Fire and Fire/Smoke Damper IOM Read all installation, operating and maintenance instructions - True Round Fire and Fire/Smoke Damper IOM thoroughly before installing or servicing this equipment. Improp- er installation, adjustment, alteration, service or maintenance can cause property damage, injury or death.
    [Show full text]
  • Specification 541 Rev. 1 – General Construction of HVAC Installations
    TABLE OF CONTENTS 1.0 SCOPE .............................................................................................................................................. 5 2.0 STANDARDS, CODES AND SPECIFICATIONS ............................................................................. 6 2.1 GENERAL SPECIFICATIONS ......................................................................................................................... 6 2.2 STANDARDS AND CODES ........................................................................................................................... 6 2.3 CERTIFICATION ................................................................................................................................................ 6 3.0 SERVICE CONDITIONS .................................................................................................................. 7 3.1 ENVIRONMENTAL CONDITIONS .............................................................................................................. 7 4.0 GENERAL REQUIREMENTS ........................................................................................................... 8 4.1 DRAWINGS AND SPECIFICATIONS .......................................................................................................... 8 4.2 MATERIAL, WORKMANSHIP AND SUITABILITY .................................................................................. 9 4.3 AREA CLASSIFICATION ................................................................................................................................
    [Show full text]
  • Dampers and Actuators Catalog for the Latest Product Updates, Visit Us Online at > Johnsoncontrols.Com
    Dampers and Actuators Catalog for the latest product updates, visit us online at > johnsoncontrols.com > johnsoncontrols.com > Building Efficiency > Integrated HVAC Systems > HVAC Control Products > Rectangular Dampers > Round Dampers > Air Control Products II Johnson Controls delivers products, services and solutions that increase energy efficiency and lower operating costs in buildings for more than one million customers. Operating from 500 branch offices in 148 countries, we are a leading provider of equipment, controls and services for heating, ventilating, air-conditioning, refrigeration and security systems. We have been involved in more than 500 renewable energy projects including solar, wind and geothermal technologies. Our solutions have reduced carbon dioxide emissions by 13.6 million metric tons and generated savings of $7.5 billion since 2000. Many of the world’s largest companies rely on us to manage 1.8 billion square feet of their commercial real estate. HVAC Dampers, Louvers and Air Control Products Since 1905, Johnson Controls has manufactured industry-leading temperature control dampers. Today, we offer a complete line of HVAC dampers and air control products including volume control, balancing, round, zone, fire, smoke and combined models. Johnson Controls is committed to customer satisfaction, and that’s why we custom-build each of our HVAC dampers to suit your specific size and model requirements. Some dampers can even be manufactured one day and shipped the next day. Actuators and accessories can be ordered with the damper and factory-installed or shipped separately depending on your needs. > Round Dampers III Introduction to Dampers The Selection Process Parallel vs Opposed Blade Operation Selecting the right damper is important to assure good Parallel blades rotate so they are always parallel to each operating characteristics in any airflow system, helping other; therefore, at any partially open position, they you maximize energy efficiency and minimize tend to redirect airflow and increase turbulence and installation costs.
    [Show full text]
  • Duct Systems
    CHAPTER 6 DUCT SYSTEMS SECTION 601 ponent of an approved engineered smoke control GENERAL system. 601.1 Scope. Duct systems used for the movement of air in [B] 601.3 Exits. Equipment and ductwork for exit enclosure air-conditioning, heating, ventilating and exhaust systems ventilation shall comply with one of the following items: shall conform to the provisions of this chapter except as oth- 1. Such equipment and ductwork shall be located exterior erwise specified in Chapters 5 and 7. to the building and shall be directly connected to the Exception: Ducts discharging combustible material exit enclosure by ductwork enclosed in construction as directly into any combustion chamber shall conform to the required by the Building Code for shafts. requirements of NFPA 82. 2. Where such equipment and ductwork is located within [B] 601.2 Air movement in egress elements. Corridors shall the exit enclosure, the intake air shall be taken directly not serve as supply, return, exhaust, relief or ventilation air from the outdoors and the exhaust air shall be dis- ducts. charged directly to the outdoors, or such air shall be conveyed through ducts enclosed in construction as Exceptions: required by the Building Code for shafts. 1. Use of a corridor as a source of makeup air for 3. Where located within the building, such equipment and exhaust systems in rooms that open directly onto ductwork shall be separated from the remainder of the such corridors, including toilet rooms, bathrooms, building, including other mechanical equipment, with dressing rooms, smoking lounges and janitor clos- construction as required by the Building Code for ets, shall be permitted, provided that each such cor- shafts.
    [Show full text]
  • Fire Induced Flow in Building Ventilation Systems (2016)
    Aalto University School of Engineering Degree programme in Mechanical Engineering Fire Induced Flow in Building Ventilation Systems Master’s Thesis 01.03.2016 Rahul Kallada Janardhan Thesis submitted in partial fulfilment of the requirements for the degree of Master of Science in Technology. Espoo, March 1, 2016 Supervisor: Prof. Simo Hostikka Advisor: Timo Korhonen 1 Author: Rahul Kallada Janardhan Title: Fire Induced Flows in Building Ventilation Systems Date: 01.03.2015 Pages: 69 + 31 Major: Mechanical Engineering Code: IA3027 Supervisor: Professor Simo Hostikka Advisor: Timo Korhonen Fast growing fires inside compartments with limited paths for expanded gases to escape leads to a rapid pressure rise. High pressure can cause smoke to flow through supply vents into the adjacent rooms and can also cause structural damage. In Finland, apartments are fitted with a distinctive double door system and the inner door opens inwards into the apartment. The opening of this door could be difficult under high pressure conditions and the effect of pressure on egress possibilities of occupants was an issue of discussion in Finland. Extensive studies have not been made to better understand the influence of ventilation networks on pressure and smoke spread possibilities. The main objective of this thesis work is to investigate the development of pressure during fires in residential buildings and the influence of ventilation networks on pressure and smoke spread through buildings. It also aims to validate the efficiency and accuracy of the CFD code, Fire Dynamics Simulator for modelling HVAC networks and provide fire safety designers with guidelines to model and simulate pressure development and ventilation system response.
    [Show full text]