<<

SENSSENSITIT 2020 PRODUCT GUIDE

INDUSTRIAL HEALTH & SAFETY

4Hazardous Monitors 4Gas Leak Detectors 4Calibration Stations 4Data Management The Company: SENSIT Technologies is an ISO 9001:2015 compliant, family-owned business located in Valparaiso, Indiana. Since 1980, we have manufactured gas leak detection products that help protect life and property.

Today, as a result of continuous innovation and commitment to customer satisfaction, the company has grown to become a global supplier to several markets:

• Energy: Natural and Gas Industries • Emergency Response: Fire Services • Industrial: Health, Safety and Maintenance • Municipal: Waterworks and Infrastructure • Service Contractors: HVAC and Plumbing

The Products: SENSIT gas detection products are best known for quickly and easily locating gas leaks and accurate measurement of toxic . Durability and low cost of ownership have added to our product popularity. SENSIT instruments can be found in many forms:

• Gas Leak Detection • Personal Gas Monitors • Infrastructure Detection

Our instruments meet approval agency standards from UL, ATEX, and CSA. Virtually all of our instruments can be linked to compliance reporting with the use of our Smart-Cal calibration and data management system. It is the final link for any total instrument program.

The People: The most important asset we have to offer is our incredible people. Our dedicated team of gas detection experts have centuries of combined experience in product development, production, sales and service. Complete customer satisfaction is our number one objective:

• Provide the exact product to meet your requirements • Exceed your expectations for service • Offer the lowest cost of ownership over the life of the product

The Future: SENSIT Technologies is committed to bringing new and innovative detection products to the global marketplace.

SENSIT Technologies 851 Transport Drive Valparaiso, IN 46383-8432

Phone: 888 473 6748 219 465 2700 Fax: 219 465 2701 Email: [email protected] Web: www.gasleaksensors.com INDUSTRIAL HEALTH & SAFETY PRODUCT GUIDE

GAS•TRAC® LZ-30 Laser Gas Detector...... 4

SENSIT® GOLD G2 Multi-Function Gas Detector...... 6

TRAK-IT® IIIa Combustible Gas Indicator...... 7

GASLESS LEAK TRAINER (GLT)...... 8

SENSIT® GOLD Multi-Function Gas Detector...... 9

SENSIT® GOLD 100 Multi-Function Gas Detector...... 10

SENSIT® HXG-3 / HXG-3P Gas Leak Detector...... 11

SENSIT® HXG-2d Gas Leak Detector...... 12

SENSIT® CO Analyzer...... 13

SENSIT® P400 Multi-Gas Personal Monitor...... 14

SCAL-400 Calibration Station for SENSIT® P400...... 15

SENSIT® P100 Single-Gas Personal Monitor...... 16

SCAL-100 Calibration Station for SENSIT® P100...... 17

SMART-CAL 360 Calibration Station...... 18

SCAL-D / SCAL-N Data Management Software...... 19 GAS•TRAC® LZ-30 Quickly and safely detect methane gas leaks in difficult to reach areas.

The LZ-30 from SENSIT Technologies is a IR / SPOTTER / DISTANCE LASER compact methane-specific leak detector that provides fast and accurate readings at distances up to 100 feet.

The LZ-30 utilizes TDLAS (tunable diode laser absorption spectroscopy) technology to provide instantaneous and accurate responses OLED DISPLAY to the presence of methane gas.

Designed to be competitively priced, the LZ-30 is perfect for hard to reach areas, eliminating the need to directly access the gas plume, OPERATION BUTTONS climb to elevated areas, or access fenced-in property and potentially hazardous situations through windows. PROTECTIVE BOOT

CHARGING TERMINALS

SPECIFICATIONS Detection Technology: Tunable Diode Laser Absorption Spectroscopy (TDLAS) Methane Detection Range: 0-50,000ppm-m in 1ppm-m increments Sensitivity: 5ppm-m ≤15m (50ft)/10ppm-m ≤30m (100ft) @ > 300ppm-m Response Time: ≤0.1 seconds Detection Distance: 0.5m to 30m (1.5’ to 100’) Distance may vary depending on reflection Distance Indicator: 0.2m to 30m (6” to 100’) Standard Features Range may vary depending on reflection • Methane selective Beam Dimension: Conical, 20cm diameter at 30m (8” at 100’) • Continuous detection Alarms: Adjustable threshold alarm with baseline: Visual and audible • Three adjustable alarm points Warnings: High/Low reflection, low battery (visual, audible and tactile) Calibration/Bump Test: Carrying case incorporates calibration/bump test cell. • Intrinsically safe design Laser classifications: IR laser (methane detection) Class 3R • Ergonomic design Target laser (green) Class 3R • Easy to maintain Distance laser (red) Class 3R • Cal Cell integrated in carrying case Communication: Bluetooth. Supported by Android. • Rechargeable battery Display: OLED • Low cost of ownership Operational Temp: -20C to 50C (-4F to 122F) • Industry leading 2-year warranty Storage Temp: -40C to 60C (-40F to 140F) (including battery) Humidity: 5 to 95% non-condensing Enclosure: Designed to meet IP54 STANDARD KIT Intrinsic Safety: Designed to meet US and ATEX • Hard Carrying Case Weight: 300g (0.7lbs) • Charger Base with Wall Transformer Size: 164mm (6.5”) x 78mm (3.0”) x 36mm (1.5”) • Protective Boot Power Source: Internal Lithium Ion • Wrist Strap Battery Life: 6 Hours Continuous • Integrated Calibration/Bump Test Cell Recharge Time: 3 to 4 Hours • Instruction Manual Languages Supported: English, French, German, Italian, Polish, Spanish

4 RY LE ST AD U II D N

GG N

II

22 YY Y TT E 2 N AR A R W ARR

5 SENSIT® GOLD G2 The most versatile and user-friendly gas leak detector available today!

Displays Up To LUER PROBE CONNECTOR 4 Gases Simultaneously • LEL (%Volume and PPM Optional) SENSOR CAP • • Carbon Monoxide LEL / PPM SENSOR • Sulfide • (Optional) INFRARED COMMUNICATIONS

Selectable Gas Type • Methane (Natural Gas) GRAPHIC DISPLAY • Propane ALARM LEDs Standard Features OPERATION BUTTONS • Intrinsically Safe Design (Certified) • Internal Pump - Fast Sampling WATER-RESISTANT HOUSING • Digital “Tick” Control - Fast Leak Location FLEXIBLE GOOSENECK • Lowest Cost, Long Life Sensors • LED Warning Lights • Bright Graphic Display • Loud Audible Alarm • Battery Strength Indicator • Internal Memory • Exceptional Water Protection BATTERY COMPARTMENT

Applications • Combustible Gas Leak Detection • Gas Leak Survey • Underground Leak Pinpointing • Carbon Monoxide Investigations TO OPERATE: • Confined Space Monitoring • Combustible Gas Measurements 1. Press Power • Pipeline Purging 2. Wait 45 Seconds for Automatic Zeroing • Method 21 Emissions Testing 3. Begin to Use • Inert Gas Operations Patented Partial List of Gases Sensed • • Carbon Monoxide • Gasoline • SENSOR SPECIFICATIONS • Methane • Natural Gas TYPE RESOLUTION RANGE ACCURACY • Oxygen • Propane PPM* 1ppm or 10ppm 0-10,000 ppm ±10% LEL 0.1% up to 2% 0-100% LEL ±10% % NAT GAS 0.1% 5-100% GAS ±5% % PROPANE 0.1% 2.2-100% GAS ±5% O2 0.1% 0-25% ±0.2% or 10%** CO 1ppm 0-2000ppm ±5ppm or 5%** H2S 1ppm 0-100ppm ±2ppm or 5%** HCN 1ppm 0-30ppm ±1ppm or 5%** *PPM Optional **Whichever is greater PPM Ranges Available: 0-2,000ppm, 0-5,000ppm, 0-10,000ppm

PRODUCT SPECIFICATIONS STANDARD KIT Size: 11.5” x 3” x 2.32” (29.2 x 7.6 x 5.9 cm) • Hard Carrying Case • Wrist Strap • 3 “C” Batteries • T10 Allen Wrench Weight: 1.2 lb. (544 g) • Extra Sensor Cap • Instruction Manual Operational Temp: -4 to 104 F (-20 to 40° C) Choice of 2 Piece Bar Hole Probe or Confined Space Probe Battery Life: Alkaline: Approximately 18 hrs. Continuous

6 TRAK-It® IIIa Combustible Gas Indicator designed for extreme working conditions.

Displays Up To PADDED CARRYING POUCH GRAPHIC DISPLAY 4 Gases Simultaneously • LEL (%Volume and PPM Optional) • Oxygen • Carbon Monoxide • Hydrogen Sulfide

Standard Features IR WINDOW • Intrinsically Safe Design (Certified) • 2-Speed Internal Pump • Identifies Natural Gas vs Propane Gas • Lowest Cost, Long Life Sensors • LED Warning Lights STATUS / ALARM LEDs • Large Bright Graphic Display • Loud Audible Alarm • Optional 1600 Event Auto Log • Exceptional Water Protection SPEAKER • Long Battery Life • Cost Effective As An Area Monitor • Infrared Downloading • Built-in Natural Gas and NECK STRAP Propane Gas Calibration • Stainless Steel Housing

Applications • Gas Line Purge • Underground Leak Pinpointing • Gas Leak Investigations • Carbon Monoxide Investigations OPERATIONAL BUTTONS PROBE ASSEMBLY • Confined Space Monitoring • Combustible Gas Measurements TO OPERATE: 1. Press Power Partial List of Gases Sensed • Butane • Carbon Monoxide 2. Wait 45 Seconds for Automatic Zeroing • Gasoline • Hydrogen Sulfide 3. Begin to Use • Methane • Natural Gas Patent Pending • Oxygen • Propane

SENSOR SPECIFICATIONS TYPE RESOLUTION RANGE ACCURACY PPM* 5ppm 0-2,000 ppm ±10% LEL 0.1% up to 2% 0-100% LEL ±10% % NAT GAS 0.1% 5.0-100% GAS ±5% O2 0.1% 0-25% ±0.2% or 10%** CO 1ppm 0-2000ppm ±5ppm or 5%** H2S 1ppm 0-100ppm ±2ppm or 5%** HCN 1ppm 0-30ppm ±2ppm or 5%**

*PPM Optional **Whichever is greater

STANDARD KIT • Padded Carrying Pouch PRODUCT SPECIFICATIONS • 4 “C” Batteries Size: 6.5” x 4” x 4.25” (16.5 x 10.2 x 10.8 cm) • Neck Strap • External Water/Dirt Filter Weight: 2.8 lb. (1.27 kg) • Instruction Manual Operational Temp: -4 to 104 F (-20 to 40° C) • Choice of Bar Hole Probe or Confined Space Probe Battery Life: Alkaline: Approximately 40 hrs. Continuous

7 GASLESS LEAK TRAINER The new standard for gas detection and emergency response training

The Gasless Leak Trainer (GLT) was designed Tablet Features/Specifications: to meet the hands-on training needs for gas emergencies and hazardous leak investigations.

The GLT system pairs a Bluetooth-enabled tablet with specially equipped SENSIT and Trak-It IIIa instruments to simulate real-world scenarios without the need for live gas. The system includes Training Mode, Monitor Mode, and Testing Mode to assist with every aspect of employee development related to hazardous gas investigations.

• Windows 10 Pro with GLT Application • Class 1 Bluetooth • Rugged Hard Case with Screen Protector • 100 Ft. Line of Site Communication • 6 Hours Continuous Battery Life • Pair Multiple GLT Enabled Instruments to Tablet The GLT allows for total control of the training • Incorporate Training Modules process. In Training mode, the trainer remotely sends commands to the user’s instrument in real • Incorporate OQ Testing (Customizable) time, allowing the employee to experience realistic • Database Backup Support scenarios in a gas-free environment. In Monitor • Supports SENSIT G2-GLT, and Trak-It IIIa GLT mode, the trainer can observe the actions taken by the employee on the instrument during an exercise or live event. In either mode, the trainer observes Operator Qualification Tests and Reports: the employee’s response to gas values, alarms, and other actions. The tablet also incorporates a customizable test to assess employee proficiency.

Key Features: • Simulates hazardous conditions without live gas • Improves employee safety and competency • Provides realistic sensor and instrument response • Includes customizable employee testing • Improves emergency response and public safety

Training Applications: • Emergency Response • Confined Space Monitoring • Leak Detection and Investigation • Gas Purging • Barhole Testing • Leak Search/Pinpointing • Carbon Monoxide Investigation

8 SENSIT® GOLD Designed to help you find the source of combustible gases fast!

Displays Up To LUER PROBE CONNECTOR 4 Gases Simultaneously • LEL (PPM Optional) SENSOR CAP • Oxygen • Carbon Monoxide LEL / PPM SENSOR • Hydrogen Sulfide • Hydrogen Cyanide (Optional) INFRARED COMMUNICATIONS

Standard Features BACKLIT LCD DISPLAY • Intrinsically Safe Design (Certified) • Lowest Cost, Long Life Sensors ALARM LEDs • Internal Pump • Water/Dust Filter OPERATION BUTTONS • Push Button Operation • Field Calibration TICK ADJUST • Date/Time Display • Calibration Alert FLEXIBLE GOOSENECK • Operation Memory • Calibration Memory • Infrared Download • Audible/Visual Alarms • Bright LCD Display • Programmable Auto Shut Off

BATTERY COMPARTMENT Applications • Combustible Gas Leak Detection • Gas Leak Survey • Underground Leak Pinpointing • Carbon Monoxide Investigations • Confined Space Monitoring TO OPERATE: • Combustible Gas Measurements 1. Press Power • Pipeline Purging • Method 21 Emissions Testing 2. Wait 45 Seconds for Automatic Zeroing 3. Begin to Use Partial List of Gases Sensed • Butane • Carbon Monoxide Patented • Gasoline • Hydrogen Sulfide • Methane • Natural Gas • Oxygen • Propane SENSOR SPECIFICATIONS TYPE RESOLUTION RANGE ACCURACY LEAK (CSA) N/A 50-50,000 ppm N/A LEAK (UL) N/A 10-50,000 ppm N/A PPM* (CSA) 1 or 10 ppm 0-2,000 ppm ±10% PPM* (UL) 1 or 10 ppm 0-2,000 ppm ±10% LEL 0.1% up to 2.0% 0-100% LEL ±10% O2 0.1% 0-25% ±0.2% or 10%** CO 1 ppm 0-2000 ppm ±5 ppm or 5%** H2S 1 ppm 0-100 ppm ±2 ppm or 5%** HCN 1 ppm 0-30 ppm ±1 ppm or 2.5%** *PPM Optional **Whichever is greater

PRODUCT SPECIFICATIONS STANDARD KIT Size: 11.5” x 3” x 2.32” (29.2 x 7.6 x 6.9 cm) • Hard Carrying Case • Wrist Strap • 3 “C” Batteries • Instruction Manual Weight: 1.2 lb. (0.5 kg) • Extra Sensor Cap Operational Temp: 0 to 120 F (-17.78 to 48.9° C) Battery Life: Alkaline: Approximately 12 hrs. Continuous

9 SENSIT® GOLD 100 A multi-function gas detector ideal for inert and purging applications.

Displays Up To LUER PROBE CONNECTOR 4 Gases Simultaneously • LEL and %Volume (PPM Optional) SENSOR CAP • Oxygen • Carbon Monoxide LEL / PPM SENSOR • Hydrogen Sulfide • Hydrogen Cyanide (Optional) INFRARED COMMUNICATIONS

Selectable Gas Type BACKLIT LCD DISPLAY • Methane (Natural Gas) • Propane ALARM LEDs OPERATION BUTTONS Standard Features • Intrinsically Safe Design (Certified) • Lowest Cost, Long Life Sensors TICK ADJUST • Internal Pump • Water/Dust Filter FLEXIBLE GOOSENECK • Push Button Operation • Field Calibration • Date/Time Display • Calibration Alert • Operation Memory • Calibration Memory • Infrared Download BATTERY COMPARTMENT • Audible/Visual Alarms • Bright Graphic Display • Programmable Auto Shut Off

Applications TO OPERATE: • Combustible Gas Leak Detection • Gas Leak Survey 1. Press Power • Underground Leak Pinpointing 2. Wait 45 Seconds for Automatic Zeroing • Carbon Monoxide Investigations • Confined Space Monitoring 3. Begin to Use • Combustible Gas Measurements • Pipeline Purging (NFPA 54 Compliant) Patented • Method 21 Emissions Testing • Inert Gas Operations • Replacement for Biosystems Cannonball 3 SENSOR SPECIFICATIONS TYPE RESOLUTION RANGE ACCURACY Partial List of Gases Sensed LEAK N/A 10-50,000 ppm N/A • Butane • Carbon Monoxide PPM* 1 or 10ppm 0-2,000 ppm N/A • Gasoline • Hydrogen Sulfide LEL 0.1% 0-100% LEL ±10% • Methane • Natural Gas % NAT GAS 0.1% 5-100% GAS ±5% • Oxygen • Propane O2 0.1% 0-25% ±0.2% or 10%** CO 1ppm 0-2000ppm ±5ppm or 5%** H2S 1 ppm 0-100 ppm ±2 ppm or 5%** HCN 1 ppm 0-30 ppm ±1 ppm or 2.5%**

*PPM Optional **Whichever is greater

PRODUCT SPECIFICATIONS Size: 11.5” x 3” x 2.32” (29.2 x 7.6 x 6.9 cm) STANDARD KIT • Wrist Strap • Hard Carrying Case • Instruction Manual Weight: 1.2 lb. (0.5 kg) • 3 “C” Batteries Operational Temp: 0 to 120 F (-17.78 to 48.9° C) • Extra Sensor Cap Battery Life: Alkaline: Approximately 12 hrs. Continuous

10 SENSIT® HXG-3/3P Displays LEL and PPM readings simultaneously for accurate leak detection and analysis.

HXG-3 Standard Features • Intrinsically Safe Design (Certified) SENSOR • Displays LEL and PPM • Audible/Visual Alarms • Infrared Downloading • Long-life, Low-Cost Sensor • Simple Calibration BACKLIT LCD DISPLAY HXG-3P Standard Features • Intrinsically Safe Design (Certified) WARNING LEDS • Internal Pump • Water/Dust Filter OPERATION BUTTONS • Displays LEL and PPM • Infrared Downloading • Long-life, Low-Cost Sensor TICK CONTROL • Simple Calibration FLEXIBLE GOOSENECK Applications • Locate Small Gas Leaks • Area Monitoring • Gas Leak Surveying • Arson/Accelerant Detection BATTERY COMPARTMENT

Partial List of Gases Sensed • Acetone • Industrial Solvents • Alcohol • Jet Fuel - 2610 • Oxide - 2610 • Butane • Lacquer Thinner TO OPERATE: • Gasoline • Methane 1. Press Power • Halon • Natural Gas 2. Wait 45 Seconds for Automatic Zeroing • Hydrogen • Propane • Refrigerants 3. Begin to Use

Patented

SENSOR SPECIFICATIONS TYPE RESOLUTION RANGE ACCURACY PPM* 1 or 10ppm 0-50,000 ppm ±10% LEL 0.1% 0-100% LEL ±10%

*PPM Optional

PRODUCT SPECIFICATIONS STANDARD KIT Size: 11.5” x 3” x 2.2” (29.21 x 7.62 x 5.89 cm) • Hard Carrying Case • Wrist Strap • 3 “C” Batteries • Instruction Manual Weight: 1.2 lb. (0.54 kg) Operational Temp: -4 to 122 F (-20 to 50° C) Battery Life: Alkaline: Approximately 25 hrs. Continuous

11 SENSIT® HXG-2d Gas leak detector with digital display for accurate measurement of gases.

Standard Features • Intrinsically Safe Design • Push-Button Operation SENSOR • Field Calibration • Backlit Display • Adjustable Alarms • Long-life, Low-Cost Sensor

Applications • Locate Small Gas Leaks ALARM LED • Area Monitoring • Gas Leak Surveying GRAPHIC DISPLAY • Chemical Detection • Arson / Accelerant Detection OPERATION BUTTONS ELECTRONIC TICK CONTROL Partial List of Gases Sensed • Acetone FLEXIBLE GOOSENECK • Alcohol • Ammonia • Butane • • Gasoline • Halon BATTERY COMPARTMENT • Hydrogen • Industrial Solvents • Jet Fuel • Lacquer Thinner • Methane • Natural Gas TO OPERATE: • Propane • Refrigerants 1. Press Power 2. Wait 45 Seconds for Automatic Zeroing The SENSIT® HXG-2d cannot be used to 3. Begin to Use check for carbon monoxide (CO) leakage.

Patent Pending

SENSOR SPECIFICATIONS TYPE RESOLUTION RANGE ACCURACY PPM* 10ppm 0-990 ppm ±10% LEL 0.1% 0-100% LEL ±10%

*PPM Optional

PRODUCT SPECIFICATIONS STANDARD KIT Size: 3.5” x 10” x 1.6” (8.9 x 25 x 4 cm) • Carrying Pouch • 3 “C” Batteries Weight: 1.2 lb. (0.544 kg) • T10 Allen Wrench Operational Temp: -4 to 104° F (-20 to 40° C) • Instruction Manual Battery Life: Alkaline: Approximately 50 hrs. Continuous

12 SENSIT® CO Use SENSIT® CO for Carbon Monoxide testing in residential and commercial buildings.

With its powerful rotary pump, hot air probe and bright LCD display, the SENSIT® CO is perfect for testing ambient air and hot gas WATER / DIRT FILTER samples. HOT AIR PROBE Infrared communication allows printing of test results to a compact printer (accessory) or PC simple and convenient. INFRARED COMMUNICATIONS Applications • CO Investigations BACKLIT LCD DISPLAY • Flue Gas Testing • Equipment Inspection & Testing ALARM LEDs

Standard Features OPERATION BUTTONS • Internal Pump • Flue Probe with Water Trap • Audible/Visual Alarms • Backlit LCD Display • Automatic Zeroing • Field Calibration • Calibration Alerts BATTERY COMPARTMENT • Memory Storage • Infrared Download • Hard Carrying Case

Optional Features

Oxygen Sensing: TO OPERATE: Display Oxygen and CO Simultaneously 1. Press Power

Air-Free CO Reading: 2. Wait 45 Seconds Automatically Calculates CO Based on for Automatic Zeroing Air-Free Calculation 3. Begin to Use

Patented

SENSOR SPECIFICATIONS TYPE RESOLUTION RANGE ACCURACY CO 1ppm 0-2,000 ppm ±5ppm or 5%** CO “Air Free”* 1ppm 0-5,000 ppm ±5ppm or 5%** O2* 0.1% 0-25% ±0.2% or 10%**

*Optional Configuration **Whichever is greater

STANDARD KIT • Hard Carrying Case • 3 “C” Batteries PRODUCT SPECIFICATIONS • Flue Probe Size: 3” x 10” x 2.4” (7.6 x 25.4 x 6cm) • 5 Foot Flexible Tubing • Particle Filter Weight: 1.1 pounds (0.5kg) • Wrist Strap Operational Temp: -4 to 104° F (-20 to 40° C) • Instruction Manual Battery Life: Alkaline: Approximately 30 hrs. Continuous

13 SENSIT® P400 Multi-gas personal monitor designed to warn the user of hazardous gases in their working environment.

P400 can be configured with 1 to 5 sensors. COMPLIANCE/ STATUS INDICATOR Standard Features • Extremely Rugged, Intrinsically Safe Design ALARM LEDs • Lowest Cost, Long Life Sensors • Audible Alarm - 3 Tone • Visual Alarm - 360° View • Vibration Alarm SENSOR AREA • STEL and TWA Alarms SENSOR FILTER • Compliance/Status Indicator • Data Logging • Easy Field Calibration • Easy Clean Dust Pre-Filter • Easy-Access Reusable Dust Filter • Alkaline and/or NiMH Battery FUNCTION BUTTONS • Limited 2-Year Warranty (Including Sensors) • Extended Warranty Available SOUNDER

P400 Optional Feature GRAPHIC DISPLAY w/BACK LIGHT Immediate Detection System (IDS) Early warning to changes in gas concentrations BELT CLIP (ON BACK) Available Sensors • Oxygen (O2) • Carbon Monoxide (CO) • Hydrogen Sulfide (H2S) TO OPERATE: • Hydrogen Cyanide (HCN) 1. Press Power 2. Wait 30 Seconds for Automatic Zeroing • Dioxide (NO2) Patented 3. Begin to Use • (SO2) • Combustible Gases SENSOR SPECIFICATIONS RESPONSE TYPE RESOLUTION RANGE ACCURACY T90 TIMES LEL 0.1% 0-100 ±10% < 10 Sec O2 0.1% 25% ±2% or 10%** < 10 Sec CO 1ppm 0-999* ±5ppm or 10%** < 10 Sec H2S 1ppm 0-100 ±2ppm or 10%** < 20 Sec HCN 0.1ppm 0-30 ±1ppm or 10%** < 20 Sec

NO2 1ppm 0-250 ±2ppm or 10%** < 20 Sec

PH3 0.1ppm 0-10 ±1ppm or 10%** < 20 Sec

SO2 0.1ppm 0-20 ±1ppm or 10%** < 20 Sec ETO 0.1ppm 0-10 ±1ppm or 10%** < 20 Sec

*CO Extended Range Available 0ppm - 1999ppm. ** Whichever is greater

STANDARD KIT KIT OPTIONS PRODUCT SPECIFICATIONS • Belt Clip • Confined-Space Entry Kit Size: 5.2” x 3.2” x 1.7” (13.2 x 8.1 x 4.0 cm) • Instruction Manual • Calibration Station Weight: 12 oz. (340 g) • Calibration Adapter • Calibration Kit Operational Temp: -4 to 122 F (-20 to 50° C) • Dust Pre-Filter • Recharger Battery Pack Humidity: 10-90% RH (Non-condensing) • Alkaline Batteries • Recharger Station Power Source: 4 “AA” Alkaline or NiMH Recharger Pack Battery Life: 24 Hr. Alkaline or 15 Hr. NiMH Typical Response Time: Initial < 2 Sec T90 <10 Sec (LEL) Sound: 98db @ 15cm

14 SCAL-400 Automatically charges, bump tests and calibrates up to five SENSIT® P400 Gas Monitors simultaneously.

TOUCH SCREEN STATUS INDICATORS CHARGING COMMUNICATION GAS PINS PIN OUTLET

GAS CONNECTIONS POWER CONNECTION USB RJ45 SERIAL

All calibration data, time, date, and sensor performance data is stored in the calibrator for download to your computer. SCAL-400 is designed for use with Data management software allows SENSIT® P400 Gas Monitors automatic uploading from calibrator, creates compliance reports and alerts selected personnel of overdue or failed • CH4 • CO • O2 • H2S calibrations. • HCN • NO2 • SO2 • Combustible Gases Standard Features: • Touch screen operation • Test up to 5 instruments simultaneously • Auto operation when instrument is installed • Indication of pass or fail • RJ45 intranet connection • Compatible with Windows 7, 8, 8.1 OS SOFTWARE REQUIREMENTS SCAL-400 30MB Hard Drive Space Reporting Features: Windows® 7, 8, 8.1 Operating System • Instrument Test Past Due Microsoft® Outlook (Preferred. Not Required) • Instrument Failure Alerts Microsoft® Excel (Preferred. Not Required) • Monthly Compliance Report ® • Sensor Performance Data Microsoft SQL Server (SQL Server Express Included) • Optional Networking System • Compatible with: SCal-DTM (Desktop) PRODUCT SPECIFICATIONS TM SCal-N (Network) Size: 24” x 7” x 3” (61cm x 17.8cm x 7.6cm) Data Management Software Weight: 5.75 lb. (2.6 kg) Operational Temp: 40 – 122 F (5 to 50° C) Max. Inlet Pressure: 20 PSI Power: 100-240 VAC

15 SENSIT® P100 Single gas personal monitor designed to warn the user of hazardous gases in their working environment.

Standard Features • Intrinsically Safe Design (Certified) • One Button Operation • Audible Alarm ALARM LEDs • Visual Alarm • Vibration Alarm • STEL and TWA Alarms • Alarm Event Memory SENSOR • Easy Field Calibration • 2-Year Operation SOUNDER • Refurbish Program Available After 2-years Of Operation • Limited 2-Year Warranty (Including Sensor) • Extended Warranty Available ON / OFF • For use with SCAL-100 Test Stations GRAPHIC DISPLAY

Available Sensors ZERO / CALIBRATE • Hydrogen Sulfide (H2S) • Hydrogen Cyanide (HCN) BELT CLIP (ON BACK) • Oxygen (O2) • Carbon Monoxide (CO) • Nitrogen Dioxide (NO2) • Sulfur Dioxide (SO2)

TO OPERATE: 1. Press Power 2. Wait 30 Seconds for Automatic Zeroing 3. Begin to Use Patented

SENSOR SPECIFICATIONS TYPE RESOLUTION RANGE *CO Extended Display Option: O2 0.1% 25% Detection Range: CO* 1ppm 0-999* 0ppm - .2% Volume H2S 1ppm 0-100 (2000ppm equivalent) HCN 0.1ppm 0-30 Resolution:

NO2 0.1ppm 0-20 1ppm for 0 – 999ppm SO 0.1ppm 0-20 01% Volume for 1000ppm – 2000ppm STANDARD KIT 2 • Belt Clip • Instruction Manual PRODUCT SPECIFICATIONS Size: 3.81” x 2.31” x 0.8” (9.67 x 5.87 x 2 cm) Weight: 3.6 oz. (105 g) Operational Temp: -4 to 104 F (-20 to 40° C) Humidity: 15-90% RH (Non-condensing) Power Source: 3.6V Lithium Battery Battery Life: 2+ Years

16 SCAL-100 Calibrates SENSIT® P100 Single Gas Monitors, stores data and manages instrument testing compliance.

All calibration data; time, date, sensor and pump performance data is stored in the LAN CONNECTION calibrator for download to your computer. POWER CONNECTION Data management software allows automatic uploading from calibrator, creates compliance IR COM reports and alerts selected personnel of overdue or failed calibrations.

Design to Test/Calibrate GAS OUTLET SENSIT® P100 Monitors • O2 MOUNTING PLATE • CO • H2S • HCN • NO2 • SO2 GAS INLET

Standard Features: RETAINING CLIP • Indicates proper gas pressure • Automatic operation when instrument is installed • Indication of pass or fail • RJ45 intranet connection • Wall or desk mount • Compatible with Windows 7, 8, 8.1 OS For use with Black P100 Models Only.

SMART-CALTM Reporting Features: • Instrument Test Past Due • Instrument Failure Alerts • Monthly Compliance Report • Sensor Performance Data • Optional Networking System • Compatible with: SCal-DTM (Desktop) SCal-NTM (Network) Data Management Software

Available Test Gases* • Oxygen - O2 • Carbon Monoxide - CO • Hydogen Sulfide - H2S • Hydrogen Cyanide - HCN • Nitrogen Dioxide - NO2 • Sulfure Dioxide - SO2 SOFTWARE REQUIREMENTS *Contact Sensit Technologies for more info. 30MB Hard Drive Space Windows® 7, 8, 8.1 Operating System Microsoft® Outlook Microsoft Excel

PRODUCT SPECIFICATIONS Size: 6” x 6” x 1.75” (15.24cm x 15.24cm x 4.5cm) Weight: 2 lb. (0.9 kg) Operational Temp: 40 – 120 F (5 to 50° C) Max. Inlet Pressure: 20 PSI Power: 100-240VAC 50/60Hz 0.2A input with 2VDC 0.5A output

17 SMART-CAL 360 Calibrates SENSIT® instruments and stores data. Compatible with SCAL 360 Data Management Software.

SMART-CAL 360 logs calibration data, time, date, LED STATUS INDICATOR sensor and pump performance and can push firmware updates to select SENSIT instruments with no need to return the instrument to the factory. SMART-CAL 360 also tracks sensor life, and gives early warning for calibration bottle replacement.

Improved data management software provides automatic data transfer for compliance reports IR WINDOW and notifications of overdue or failed calibrations. (LEFT SIDE) Logs can be viewed on the large touchscreen display or reports via emailed spreadsheet or pdf. SMART-CAL 360 communicates over Wi-Fi, so that the station can be positioned where it is most convenient and accessible, and it works with any SMART-CAL compatible instrument. 7 INCH TOUCH SCREEN Standard Features: • 7” Touchscreen • IR/NFC/Bluetooth Communications • Automatic Upload of Records • Calibration/Bump Memory Storage • SD Card: Database Backup Configuration Backup Station Firmware Updates • Gas Bottle Supply Monitoring • Configurable Valves • Wireless Firmware Updates Pushed To Devices WI-FI ANTENNA • Wi-Fi/LAN Equipped (Network Stations) • USB (Desktop Stations) • Filtered/Replaceable Gas Port Connections • LED Status Indicator (Busy, Ready, Pass, Fail, Check Gas Supply) • Automatic Date Adjustment GAS PORT CONNECTIONS

INSTRUMENT HOSE Data Management Software (Sold Separately) USB PORT SCAL-D 360 15 VDC INPUT DOWNLOAD PORT SCAL-D 360 (Desktop) USB PORT SCAL-N 360 (Network) FOR FUTURE EXPANSION

Reporting Features: • Instrument Test Past Due • Instrument Failure Alerts ETHERNET CONNECTION • Monthly Compliance Report SCAL-N 360 COMMUNICATION PORT • Custom Reports SD CARD SLOT • Service Reports FOR DATABASE / CONFIGURATION BACKUP / FIRMWARE UPDATES • Calibration Gas Expiration Reports

Text Alerts: PRODUCT SPECIFICATIONS • Sensor Performance Data Size: L= 10.6” x W= 5.4” x H= 6.1” (27cm x 13.7cm x 15.5cm) • Optional Networking System Weight: 4.1lbs (1.86kg) Operational Temp: 32°F to 122°F (0°C to 50°C) SCAL-D/N 360 Data Management Software Max. Inlet Pressure: 30psi (2 bar) Compatible with SMART-CAL 360, SMART-CAL, Power: Transformer Input 110 to 240 VAC/Output 15VDC SCAL-100, SCAL-400 SOFTWARE REQUIREMENTS 1 GB Hard Drive Space Microsoft® Outlook Windows® 7, 8, 8.1, 10 Operating System Direct Email Windows® Server: 2008, 2008 R2, 2012, 2012 R2, 2016, 2019

18 SCAL 360 Data Management Software for use with SMART-CAL 360 & SCAL Calibration Stations

Use SCAL Data Management Softwareto download data from Calibration Stations.

SCAL-D 360 is the Desktop version of the software. Various reports and alerts can be viewed, printed, emailed, or stored as an Excel spreadsheet. When configured, it will automatically alert operators and supervisors of important data depending on their preference.

SCAL-N 360 is the Network version of the software. Use SCAL-N 360 to download data from remotely located Calibration Station(s). Data is stored in the SQL Server.

SCal-N is divided into two categories:

Admin Application: HARDWARE REQUIREMENTS SMART-CALTM Calibration Station The Admin application is the host for the Designed for use with: automatic downloading of remote Calibration ® ® Stations that have the proper communication • SENSIT CO • SENSIT HXG-3P hardware installed. This program is SQL • SENSIT® GOLD • SENSIT® IRED Server based. You must install and use only • SENSIT® GOLD CGI • SENSIT® PMD one copy of SCAL-N as Admin. • SENSIT® GOLD G2 • Trak-It® III CGI • SENSIT® HCN • Trak-It® IIIa User Application: • SENSIT® HXG-3 The User Application allows viewing of selected data stored in the Server database SCAL-400 Calibration & Charging Station from any computer that has access or Designed for use with: privileges. An authorized login and password • SENSIT® P400 to the SQL Server is required for each User application installed.

*Contact Sensit Technologies for more info. SCAL-100 Calibration Station Designed for use with: • SENSIT® P100 (Black Housing)

SOFTWARE REQUIREMENTS 1 GB Hard Drive Space Windows® Operating System: 7, 8, 8.1, 10 Windows® Server: 2008, 2008 R2, 2012, 2012 R2, 2016, 2019 Microsoft® Outlook Direct Email

PRODUCT SPECIFICATIONS SCAL-D or SCAL-N Software (User Guide Included) Printed Installation Guide

19 Why Choose

• User-Friendly, Durable Instruments • Lowest Cost of Ownership SENSIT • Unmatched Service and Support

SEE A PRODUCT THAT INTERESTS YOU? SENSIT Instruments Detect One Or More Of The Following Gases:

• Natural Gas - Blend • Carbon Monoxide - CO Try-It • Hydrogen Cyanide - HCN • Hydrogen Sulfide - H2S CALL FOR DETAILS • Methane - CH4 • Nitrogen Dioxide - NO2 Call today, to learn more about our • Oxygen - O2 Try-It Offer for qualified users. • Propane - C3H8 • Sulfur Dioxide - SO2 Toll-Free: 888 473.6748 • Volatile Organic Compounds - VOCs

View Our Entire Product Line: www.gasleaksensors.com

Distributed by:

MADE IN THE USA WITH GLOBALLY SOURCED COMPONENTS 851 Transport Drive Valparaiso, IN 46383-8432

Phone: 888 4SENSIT SENSIT Technologies 888 473 6748 is an ISO 9001:2015 certified company. 219 465 2700

Fax: 219 465 2701 www.gasleaksensors.com

© 2020 SENSIT TECHNOLOGIES 3/10/2020