Chapter 296-96 WAC SAFETY REGULATIONS and FEES FOR

Total Page:16

File Type:pdf, Size:1020Kb

Chapter 296-96 WAC SAFETY REGULATIONS and FEES FOR Chapter 296-96 Chapter 296-96 WAC SAFETY REGULATIONS AND FEES FOR ALL ELEVATORS, DUMBWAITERS, ESCALATORS AND OTHER CONVEYANCES (Formerly chapters 296-81, 296-82, 296-84, 296-85, 296-87, 296-89, 296-91, 296-93A, 296-94, 296-95, and 296-100 WAC) WAC 296-96-01035 Are there inspection fees? 296-96-01040 What is the fee for testing and inspecting regular eleva- PART A - ADMINISTRATIVE tors used as temporary elevators to provide trans- 296-96-00500 Scope, purpose, and authority. portation for construction personnel, tools, and 296-96-00600 What rules apply to your conveyance? materials only? 296-96-00650 Which National Elevator Codes and Supplements has 296-96-01045 What are the inspection requirements and fees for con- the department adopted? veyances in private residences? 296-96-00700 Chapter definitions. 296-96-01050 How do I get a supplemental inspection? 296-96-00800 Advisory committee on conveyances. 296-96-01055 Are technical services available and what is the fee? 296-96-00805 Appeal rights and hearings. 296-96-01057 Does the department charge a fee to perform investiga- tions and what is the fee? PART B - ELEVATOR CONTRACTOR AND CONVEYANCE 296-96-01060 Can I request an after hours inspection and what is the MECHANIC LICENSES AND REGULATIONS AND FEES fee? 296-96-01065 What are the annual operating certificate fees? NOTE: Total fees include the sum of the permit cost plus plan check fees. 296-96-01070 What are the civil (monetary) penalties for violating the 296-96-00900 In general, who is required to be licensed under this conveyance permit and operation requirements of chapter? chapter 70.87 RCW and this chapter? 296-96-00902 Are there exceptions from the elevator mechanic licens- 296-96-01075 How does an owner or licensee receive a variance from ing requirements? the installation and alteration requirements of chap- 296-96-00903 Are there exceptions from the elevator contractor licens- ter 70.87 RCW and this chapter? ing requirements? PART C - REGULATIONS FOR NEW AND ALTERED ELEVATORS 296-96-00904 What must you do to become and remain a licensed ele- AND LIFTING DEVICES vator contractor? 296-96-00906 What must you do to become a licensed elevator NOTE: The following rules set the minimum standard for all new mechanic? installations and, where applicable, alterations. 296-96-00910 What are the elevator mechanic license categories? NOTE: Part C is not intended to replace the current adopted standards 296-96-00912 How long is the elevator contractor, elevator mechanic, outlined in WAC 296-96-00650. In conflicts between Part C and the and temporary mechanics licensing period and what adopted standards, Part C will take precedent. is required for renewal? 296-96-00914 Where can you obtain information regarding depart- 296-96-02400 When must the department be notified for a new or ment-approved continuing education course pro- altered inspection? viders? 296-96-02405 What is the inspection and approval process for altera- 296-96-00916 Who approves and what is the process for becoming a tions? continuing education course provider? 296-96-02410 Are there additional work requirements when perform- 296-96-00918 Who is exempt from the continuing education require- ing an alteration? ments? 296-96-02415 What are the conditions for obtaining a temporary con- 296-96-00920 When and where are elevator licensing examinations struction operating permit? held? 296-96-02420 What are the requirements for temporary construction 296-96-00922 What are the fees associated with licensing? operating permits? 296-96-00924 What procedures does the department follow when issu- 296-96-02425 Where is a shut-off valve required for hydraulic eleva- ing a civil penalty for licensing violations? tors? 296-96-00926 What are the civil (monetary) penalties for violating the 296-96-02450 Can pipes and ducts be installed above a machine room? licensing requirements of chapter 70.87 RCW or 296-96-02455 What is the minimum working space required in this chapter? machine rooms? 296-96-00930 What if I owe outstanding final judgments to the depart- 296-96-02460 What are the requirements for electrical main line dis- ment? connects? PART B-1 - PERMIT REGULATIONS AND FEES, PENALTIES AND 296-96-02465 What are the requirements associated with elevator INSPECTION TYPES FOR ALL CONVEYANCES machine rooms? 296-96-01000 What is the permit process for conveyances? Fire Service, Sprinklers, Sprinkler Pipes, Shunt Trip 296-96-01005 When do I need and what are the steps in obtaining a permit? 296-96-02470 What are the requirements for Fireman's Service Phase I 296-96-01006 What type of conveyance work requires permitting and and Phase II recall? inspection? 296-96-02475 What are the requirements for sprinklers in hoistways 296-96-01009 Who can purchase a permit? and machine rooms? 296-96-01010 What are the installation permit fees for conveyances, 296-96-02480 How does the department enforce ASME requirements material lifts, and hoists and how are they calcu- for sprinklers, smoke detectors, and heat detectors lated? in hoistways and machine rooms? 296-96-01012 What are the permit fees for alterations to conveyances, Car(s) material lifts, and hoists and how are they calcu- lated? 296-96-02485 What is required for emergency escape hatches? 296-96-01025 What is the permit fee for personnel and material hoists? 296-96-02490 Are there exceptions for correction facility elevators? 296-96-01027 Are initial installation permit fees refundable? 296-96-02495 Are self-leveling devices required? 296-96-01030 What is the process for installation and alteration plan 296-96-02500 Is a door reopening device required on automatic-clos- approval? ing car doors? (3/6/12) [Ch. 296-96 WAC—p. 1] Chapter 296-96 Safety Regulations and Fees for All Conveyances 296-96-02505 What is the minimum acceptable initial transfer time for PART C2 - CONSTRUCTION, OPERATION, MAINTENANCE AND an elevator door? INSPECTION OF INCLINED PRIVATE RESIDENCE ELEVATOR FOR 296-96-02510 What are the minimum cab size and other applicable TRANSPORTING PERSON(S) requirements for car interiors? 296-96-02515 What is required for car controls? 296-96-07010 What is the scope of Part C-2? 296-96-02520 What are the location and operation requirements for car 296-96-07020 What is the definition for inclined private residence ele- position indicators in the car? vator? 296-96-02525 What is required for installation and operation of emer- 296-96-07021 What are the requirements for existing inclined private gency communication systems? residence elevators? 296-96-02530 What requirements apply to the size and location of car 296-96-07024 What rules apply to alterations of inclined private resi- handrails? dence elevators? 296-96-02535 What requirements apply to floor designations on eleva- 296-96-07030 Does the department approve private residence elevator tor door jambs? plans and specifications? 296-96-02540 What are the installation and operation requirements for 296-96-07035 What are the minimum maintenance requirements for hall buttons? inclined private residence elevators? 296-96-02545 What are the requirements for installation and operation 296-96-07040 What are the clearance requirements for an incline run- of hall lanterns? way? 296-96-07050 What are the construction requirements for car landing Hoistway and Pit enclosures and gates for inclined private residence elevators? 296-96-02550 What are the requirements for underground hydraulic 296-96-07060 What types of bumpers and buffers must be installed on elevator pipes, fittings, and cylinders? inclined private residence elevators? 296-96-02555 What are the requirements for accessing elevated eleva- 296-96-07070 What are the requirements for machinery beams and tor pit equipment? supports? 296-96-02560 What are the requirements for submersible pumps or 296-96-07080 What are the load and size requirements for car plat- sumps? forms? 296-96-02565 What are the requirements for top of car lighting for 296-96-07090 What is the maximum rated speed of an incline eleva- freight and passenger elevators? tor? 296-96-02570 How do we enforce hoistway ventilation? 296-96-07100 What construction requirements apply to inclined pri- 296-96-02575 How do we enforce hoistway pressurization? vate residence elevators? Outside Hoistway 296-96-07110 What construction requirements apply to car enclo- sures? 296-96-02580 Are keys required to be on-site? 296-96-07120 What construction requirements apply to car doors and 296-96-02585 What are the requirements for fire doors installed in gates? front of hoistway doors? 296-96-07130 What type of glass or plastic can be used in a car enclo- sure? LULA 296-96-07140 Are capacity and data plates required? 296-96-02590 When does the department require a local building offi- 296-96-07150 What are the construction requirements for guide rails, cial to sign off for the installation of LULAs, stair track supports and fastenings? lifts, inclined wheelchair lifts and vertical wheel- 296-96-07160 What construction requirements apply to counter- chair lifts? weights? 296-96-02595 What are the general requirements for LULA elevators? 296-96-07170 What are the requirements of safeties and governors? 296-96-07171 How and when are safeties and governors tested? Accessibility Equipment 296-96-07180 What are the construction requirements for driving machines and sheaves? 296-96-02600 What is required for physically handicapped lifts? 296-96-07190 What construction requirements apply to terminal stop- 296-96-02605 Are private residence inclined stairway chairlifts ping
Recommended publications
  • Moving Individuality …
    Moving Individuality … ... with inclined elevators 3 2 Going up since 1876. For special and individual elevator equipment New possibilities with inclined elevators solutions we at Hütter Aufzüge have been the right partner for over 130 years. We are a medium-sized Our expertise is in demand world-wide, in particular company and managed by what is already the with regard to innovative inclined elevators, which fourth generation of the founding family. We are 1876: Heinrich Hütter founds Maschinenfabrik H. Hütter Jr. 1989: Achim Hütter, the fourth generation, takes over often represent a more effective and economical specialised in the design, production and installation alternative to classical vertical elevators – or even Just a few years later the fi rst elevators were offered. management of the business. of complete special elevators and elevator open up completely new possibilities of mobility. In components, tailored exactly to the specifi cations in 1916: The second generation: Heinrich Hütter takes over 1994: Restruction of the company to H. Hütter Jr. this sector we are regarded as one of the leading terms of construction, planning, function and design. international suppliers. the company after the death of his father. Verwaltungs-KG, Hütter-Aufzüge GmbH and However unusual or demanding the project might 1943: The company premises are totally destroyed in the Hütter-Aufzüge Service GmbH. For example, inclined elevators enable train be: we have the experience and the know-how, to stations to be retrofi tted at comparatively little Second World War. 1999: Bernd Hütter enters the company as Managing Director. achieve impressive, superior quality, turnkey effort with access for disabled persons.
    [Show full text]
  • Steering Committee Bonita to Bridgeport May 13, 2019 Bonita to Bridgeport Timeline
    Steering Committee Bonita to Bridgeport May 13, 2019 Bonita to Bridgeport Timeline 2 2 Options Considered 1. Fewer business impacts Detailed traffic study by the end of 2019 will help partners collaborate on at-grade 2. Lower cost with fewer risks to project crossing design. schedule 3. Station at Upper Boones Ferry Road serves • Safety –follow industry best practices employment center • Transit reliability and travel time –make 4. Multiple potential designs for Bridgeport transit fast and easy Station, including option with no business • Traffic issue –motor vehicle queuing, level displacements of service, delay –meet 2035 “no-build” conditions (2045 at I-5 ramps) Comparison of Options LPA At-Grade, Refined Traffic Issues 7 7 Future Planned Projects 8 10 10 April 25th Open House • About 30 people; 10 comment cards • Many supported LPA elevated (for traffic and avoiding business impacts) • A few supported 74th Ave, refined (for station at 74th & Upper Boones) • A few supported LPA at-grade, refined • Many advocated for bike and pedestrian access to stations 11 Community Advisory Committee (CAC) feedback • Unanimous concurrence with staff findings • Additional Considerations: • Safety improvements for people walking and biking at Upper Boones crossing • Freight mobility at 72nd & Upper Boones • Interconnected signals • Robust support for relocated businesses 12 Staff Recommendation: LPA At-Grade, Refined 1. Fewer business impacts Detailed traffic study by the end of 2019 will help partners collaborate on at-grade crossing design. 2. Lower cost with fewer risks to project schedule 3. Station at Upper Boones Ferry Road serves • Safety –follow industry best practices employment center • Transit reliability and travel time –make 4.
    [Show full text]
  • TCQSM Part 8
    Transit Capacity and Quality of Service Manual—2nd Edition PART 8 GLOSSARY This part of the manual presents definitions for the various transit terms discussed and referenced in the manual. Other important terms related to transit planning and operations are included so that this glossary can serve as a readily accessible and easily updated resource for transit applications beyond the evaluation of transit capacity and quality of service. As a result, this glossary includes local definitions and local terminology, even when these may be inconsistent with formal usage in the manual. Many systems have their own specific, historically derived, terminology: a motorman and guard on one system can be an operator and conductor on another. Modal definitions can be confusing. What is clearly light rail by definition may be termed streetcar, semi-metro, or rapid transit in a specific city. It is recommended that in these cases local usage should prevail. AADT — annual average daily ATP — automatic train protection. AADT—accessibility, transit traffic; see traffic, annual average ATS — automatic train supervision; daily. automatic train stop system. AAR — Association of ATU — Amalgamated Transit Union; see American Railroads; see union, transit. Aorganizations, Association of American Railroads. AVL — automatic vehicle location system. AASHTO — American Association of State AW0, AW1, AW2, AW3 — see car, weight Highway and Transportation Officials; see designations. organizations, American Association of State Highway and Transportation Officials. absolute block — see block, absolute. AAWDT — annual average weekday traffic; absolute permissive block — see block, see traffic, annual average weekday. absolute permissive. ABS — automatic block signal; see control acceleration — increase in velocity per unit system, automatic block signal.
    [Show full text]
  • Chapter 405. Elevators and Other Lifting Devices
    Ch. 405 ELEVATORS AND LIFTING DEVICES 34 CHAPTER 405. ELEVATORS AND OTHER LIFTING DEVICES GENERALLY Sec. 405.1. Scope. 405.2. Standards. 405.3. Permit application. 405.4. Approved designs, equipment and devices. 405.5. Acceptance inspection. 405.6. Certificate of operation. 405.7. Periodic inspections. 405.8. Periodic testing. 405.9. Periodic dynamic testing. 405.10. Major repairs, replacements and alterations. 405.11. Accident report. 405.12. Lumber elevators. STAGE, ORCHESTRA AND ORGAN CONSOLE ELEVATORS 405.31. Applicability. 405.32. Platforms. 405.33. Shaftway requirements. 405.34. Projections and recesses. 405.35. Landing doors. 405.36. Lifting capacity. 405.37. Operating speed. 405.38. Operating controls. 405.39. Switches. 405.40. Pit and pit access. 405.41. Single operator requirement. 405.42. Additional requirements. Authority The provisions of this Chapter 405 issued under sections 105(c) and 301 of the Pennsylvania Con- struction Code (35 P. S. §§ 7210.105(c) and 7210.301), unless otherwise noted. Source The provisions of this Chapter 405 adopted January 9, 2004, effective April 9, 2004, 34 Pa.B. 319, unless otherwise noted. Cross References This chapter cited in 34 Pa. Code § 403.22 (relating to health care facilities); 55 Pa. Code § 2600.97 (relating to elevators and stair glides); and 55 Pa. Code § 2800.97 (relating to elevators and stair glides). 405-1 (351243) No. 431 Oct. 10 34 § 405.1 UNIFORM CONSTRUCTION CODE Pt. XIV GENERALLY § 405.1. Scope. (a) Application of chapter. This chapter constitutes the Uniform Construction Code technical requirements for elevators and other lifting devices. This chapter applies to the construction, alteration, addition, repair, movement, equipment, removal, maintenance, use and change in use of every elevator and lifting device after April 9, 2004.
    [Show full text]
  • Antti Pusa Effects of Velocity Gradients on Human Body
    ANTTI PUSA EFFECTS OF VELOCITY GRADIENTS ON HUMAN BODY Master of Science Thesis Examiner: Prof. Jouni Kivistö-Rahnasto Supervisor: Dr. Jussi Lähteenmäki The examiner and topic of thesis were approved on May 31st 2017 by the Faculty of Mechanical Engineering and Industrial Systems, Tampere University of Technology i ABSTRACT ANTTI PUSA: Effects of velocity gradients on human body Tampere University of Technology Master of Science Thesis, 76 pages, 5 Appendix pages September 2017 Master’s Degree Programme in Mechanical Engineering Major: Safety Engineering Examiner: Professor Jouni Kivistö-Rahnasto Supervisor: Dr. Jussi Lähteenmäki Keywords: velocity gradients, balance, postural control, elevator, escalator, moving walk The number of elevators, escalators and moving walks are increasing each year. Respectively, accident rates, such as losing of balance, are increasing. Escalators and inclined moving walks are considered more hazardous than elevators, as the injuries per machine are significantly higher with escalators. For example, in 2007, the number of injuries per escalators were more than 20 times greater than with injuries per elevators in the USA. Falling accidents are e.g. due to velocity gradients: acceleration and deceleration. It has been estimated that approximately 2,5 % of escalator stops result in passenger fall. This thesis studies the effects of velocity gradients on the human body with elevator, escalator and moving walk applications. The study is a literature review where accident statistics, the most well-known vertical transportation safety standards and several balance studies are analyzed individually and compared with each other. ASME A17.1, EN 81-20, EN 115 and Japanese codes offer safety instructions and limitations on the effects of velocity gradients.
    [Show full text]
  • Technical Standards and Safety Authority ACTIVE Code Adoption
    ACTIVE Code Adoption Documents, Guidelines, Advisories, Director's Orders & Director's Safety Orders as of May 5, 2020 Elevating and Amusement Devices Safety Program Technical Standards and Safety Authority This file contains documents (or regulatory instruments) that form part of Ontario's Elevating Devices Regulatory Landscape. The documents enclosed are those which are considered to be in Active status as of the date of this publishing. For historic and archived versions please refer to the ARCHIVED Regulatory Documents Binder (ED-SKI). Technical Standards & Safety ACTIVE Code Adoption Documents, Guidelines, Advisories, Director's (Safety) Orders Authority This file contains current Active regulatory communucation tools Compliance Yrs Yrs ID No. Date Active Is Past Due? Enforcement Purpose that form part of Ontario's Elevating Devices Regulatory Landscape Due Date Past Due Old Compliance Yrs Past Yrs Old @ ID No. Date CODE ADOPTION DOCUMENT Status1 Status2 Enforcement Purpose By Due 2020-05-05 277-19 Feb-01-19 ED CAD Amendment - Updated to Parts 1,2,4,5,8, Re-Issue Parts 3,6,7 Active Mandatory Regulatory 0.00 1.30 272-18 amendment Mar-30-20 SLM Continuing Education Requirements Active Mandatory Education Requirement 2020-09-26 -0.35 0.14 272-18 May-16-18 SLM Continuing Education Requirements Active see temporary amendment Mandatory Education Requirement 2019-01-01 1.38 2.01 268-14 Dec-05-14 Requirements for Transport Platforms Active Mandatory Regulatory 2017-12-05 2.46 5.46 265-14 Jan-07-14 Construction Hoist Interlocks Active Mandatory Regulatory 2014-01-07 6.37 6.37 194-08 Oct-08-08 Regulation of Parking Garage Lifts Active Mandatory Regulatory 2009-01-01 11.39 11.62 Compliance Yrs Past Yrs Old @ ID No.
    [Show full text]
  • Meeting #2 Summary Wednesday, March 13, 2018, 4:00 – 6:00Pm Vey Conference Center, OHSU Campus
    SW Corridor Light Rail Project Marquam Hill Connector Green Ribbon Committee Meeting #2 Summary Wednesday, March 13, 2018, 4:00 – 6:00pm Vey Conference Center, OHSU Campus Committee Members in Attendance Fred Miller (Chair), Doug Kelsey, Skai Dancey, Todd Lofgren, Zari Santner, Councilor Bob Stacey, Jamey Duhamel, Anton Vetterlien, Chet Orloff, Don Stastny Absent: None Presenters: Carol Mayer-Reed & Shannon Simms (ZGF-VIA-Mayer/Reed Joint Venture) Public Comment Four people from the audience made comments: 1. A representative from the SWIRL transportation committee spoke in support of better transit between SW neighborhoods and OHSU. She encouraged realignment of N/S bus service to better serve destinations. 2. A local architect spoke. He worked on numerous projects around OHSU and was on the Design Commission during the process for the aerial tram. He talked about a previous proposal he had developed for a 2,000 car parking garage at the site of the current synagogue building. It would include a visitor center for Marquam Hill. He called the site a “solar plexus” and said that there would be high private interest in building this as a partnership with OHSU. 3. A member of the Friends of Terwilliger group spoke about the importance of the environmental regulations of the site. He encouraged information on that to be presented as soon as possible as it might limit the options. 4. A representative from the Homestead Neighborhood Association, and a member of the Working Group, spoke about his concern with building a “landmark.” He said that there could still be an “iconic experience” without the connection being a landmark.
    [Show full text]
  • Michigan Department of Licensing and Regulatory Affairs Michigan Elevator Rules 2010 Edition
    Michigan Department of Licensing and Regulatory Affairs Michigan Elevator Rules 2010 Edition Bureau of Construction Codes P.O. Box 30254 Lansing, Michigan 48909 www.michigan.gov/bcc INTRODUCTION Amendments to the Elevator Code Rules become effective July 11, 2014. The rules adopt by reference the American Society of Mechanical Engineers (ASME) safety code for elevators and escalators, ASME A17.1- 2010, the safety code standard for platform lifts and stairway chairlifts, ASME A18.1-2011, the safety code standard for inspection of elevator, escalators, and moving walks, ASME A17.2-2012, the safety code standard for belt manlifts, ASME A90.1-2009, and the American National Standards Institute (ANSI) safety requirements for personnel hoists and employee elevators for construction and demolition operations, A10.4- 2007. This edition of the Michigan Elevator Rules has been denoted as the “2010 Edition”. The rule set takes exception to and amends portions of the 2010 Edition of the American Society of Mechanical Engineers (ASME) A17.1 Safety Code for Elevators and Escalators. Since a considerable portion of the Michigan rules address our modifications to the 2010 ASME A17.1 standards, we felt it appropriate to designate this as the “2010 Edition.” It is our intent to continue this practice, and future editions of the Michigan Elevator Rules will refer to the edition of the ASME A17.1 which the rule set references. Vertical lines denote amendments and additions to easily identify changes from the previous edition. This rule set is published in chapters, i.e., Chapter 1 General Provisions; Chapter 2 All Elevators; Chapter 3 ASME A17.1 Safety Code for Elevators and Escalators Modifications; Chapter 4 ASME A18.1 Safety Standard for Platform Lifts and Stairway Chairlifts, Modifications, etc.
    [Show full text]
  • ELEVATING DEVICES CODE ADOPTION DOCUMENT Unofficial Consolidation
    ELEVATING DEVICES CODE ADOPTION DOCUMENT June 1, 2001 as amended Consolidated on January 4, 2013 The June 1, 2001 CAD as amended by: CAD Amendment 255-12 [Effective March 1, 2013] CAD Amendment 250-11 [Effective May 1, 2012] CAD Amendment 246-11 [Part 1,2,3,4,6,7 effective immediately, Part 5 effective October 1, 2011] A consolidation of: CAD Amendment 239/10 CAD Amendment 238/09 CAD Amendment 225/07-r3 CAD Amendment 216/07 CAD Amendment 213/07 CAD Amendment 212/07-r1 pages marked include errata and/or pending CAD revisions ELEVATING DEVICES CODE ADOPTION DOCUMENT Unofficial Consolidation Issued by: ELEVATING AND AMUSEMENT DEVICES SAFETY PROGRAM TECHNICAL STANDARDS AND SAFETY AUTHORITY FORWARD O.Reg. 209/01 Elevating Devices Regulation made under the Technical Standards and Safety Act adopts the Code Adoption Document (CAD) for the Province of Ontario. Definitions in the Code Adoption Document have the same meaning as O.Reg. 209/01 Elevating Devices Regulation made under the Technical Standards and Safety Act. The Code Adoption Document establishes essential requirements and minimum standards for the design; construction; installation; erection, maintenance, alteration to elevating devices. This unofficial consolidation is a collection of CAD amendments. On April 15, 2011, TSSA published CAD Amendment 246/11 which consolidated the requirements of CAD Amendments 239/10, 238/09, 225/07-r3, 216/07, 213/07, 212/07-r1. Effective April 15, 2011: Parts I, II, III, IV, VI, and VII of the Elevating Devices CAD are revoked and replaced with Parts 1, 2, 3, 4, 6, 7. Effective October 1, 2011: Part V of the Elevating Devices CAD is revoked and replaced with Part 5.
    [Show full text]
  • (HEC) Bale Elevator Manual Manual
    HEC Standard Bale Elevator Owner’s and Operator’s Manual Read and Understand this manual Before Operating WARNING WARNING Operator’s Manual! Additional Assistance If any items covered in this manual are not fully understood by you, contact your dealer or T. R. Metal Crafters, Inc.; 312 E. Industrial Dr.; P.O. Box 248; Loyal, WI 54446 (call Toll Free 1-800-842-5349 for assistance). 111512 12171 General Safety Statement It is your responsibility as an owner, operator or supervisor to know what specific requirements, precautions and work hazards exist and to make these known to all other personnel working with the equipment or in the area, so that they too may take any necessary safety precautions that may be required. Failure to read this Owner’s and Operator’s Manual and its safety instructions is a misuse of the equipment. Operator’s Manual! The Operator’s Manual Anyone who will operate or work around an elevator or transport shall first read the Owner’s and Operator’s Manual! Complete sign-off sheet in “Operator Qualifi- WARNING cations” section of this Manual to document training. Safety Alert Symbol This Safety Symbol means: Attention! Become Alert! Your Safety Is Involved! The Safety Alert Symbol identifies important safety messages on machines, safety decals, in manuals, or elsewhere. When you see this symbol, be alert to the pos- sibility of personal injury or death. Follow the instructions in the safety message. This symbol will be used with one of three signal words: CAUTION WARNING DANGER to indicate the degree of hazard. CAUTION — Hazards or unsafe practices which COULD result in minor personal injury or product or property damage.
    [Show full text]
  • United States Patent (19) 11 Patent Number: 5,566,621 Wanvik Et Al
    USOO5566.621A United States Patent (19) 11 Patent Number: 5,566,621 Wanvik et al. (45) Date of Patent: Oct. 22, 1996 (54) CONVEYOR ARRANGEMENT FOR 4,681,039 7/1987 Perrin ................................... 104,173.2 ROLLING TRANSPORT DEVICES 4,928,601 57 1990 Harder et al. ............................. 04/53 5,140,910 8/1992 Welter ........ ... 104,162 76) Inventors: Jarle Wanvik, Skule Bárdsons qt. 5; 5,199,358 4/1993 Barratt .................................... 104/139 Stein Lovoll, Strindveien 45, both of FOREIGN PATENT DOCUMENTS N-7016 Trondheim, Norway 0775898 /1968 Canada .................................. 104f62 (21) Appl. No.: 362.585 2668836 4f1992 France ...... ... 104,173.2 338544 6/1921 Germany .. ... 104,173.1 22) PCT Filed: Jul. 9, 1993 1661093 7/1991 U.S.S.R. ................................ 04f62 86) PCT No.: PCT/NO93/00112 1698154 12/1991 U.S.S.R. ................................ 104f162 Primary Examiner-Mark T. Le S371 Date: Jan. 6, 1995 Attorney, Agent, or Firm-Pittenger & Smith, P.C. S 102(e) Date: Jan. 6, 1995 57 ABSTRACT (87) PCT Pub. No.: WO94/01313 An inclined elevator compreses a traveling chain, rope or PCT Pub. Date:Jan. 20, 1994 cable with one or more push devices fixed to it at intervals. (30) Foreign Application Priority Data The elevator is intended for bicyclists or similar manned Jul. 10, 1992 NO Norway .................................... 921781 vehicles and is designed for installation in inclined streets, pedes-trian tracks or in separate tracks specially designed for (51) Int. Cl. ....................................... B61B 11/00 the purpose. 52 U.S. Cl. ......................... 104/173.1; 104/53; 104/139; 104/162 The elevator chain, cable or rope is running in a conduit with 58) Field of Search ....................................
    [Show full text]
  • The World of Ropeways
    The World of Ropeways … to top performance. From challenge … 2|3 The World of Ropeways World leader As a customer of the Doppelmayr/Garaventa Group, networks. Our systems for material transport and rope- you can count on the best quality, leading-edge ways for preventive avalanche blasting offer impressive ropeway technology and the utmost professionalism. efficiency and performance. All-year-round experience We develop our products in close collaboration with our concepts round off our extensive portfolio. customers and partners in order to arrive at the ideal solution to meet your individual wishes and needs. With Doppelmayr/Garaventa, you get top quality in When it comes to implementing your project, the very modern design, discover user-friendly solutions and latest technologies and the full in-depth experience know you will continue to receive optimum service in of our engineers and technicians are employed. the future. From the initial idea to the completed project All this makes the Doppelmayr/Garaventa Group and beyond. the world leader in ropeway engineering – and your reliable partner. Our transport systems set benchmarks: We transport passengers with ropeways offering not only top comfort but above all safety at the highest level – in summer and winter tourism regions or as part of urban transit 4|5 The World of Ropeways The Doppelmayr/Garaventa Group 2002 saw the merger of two leading ropeway manu- Today, the Doppelmayr and Garaventa brands stand facturers with a long tradition: Doppelmayr and for top quality and uncompromising reliability. In- Garaventa. This gave rise to the Doppelmayr/ stallations designed precisely to accommodate the Garaventa Group with its main plants in Wolfurt (AUT) customer’s wishes and pioneering innovations in and Goldau (CHE) as global competence centers ropeway construction sum up a corporate philosophy for circulating ropeway systems such as gondolas which strikes a chord with operators around the globe.
    [Show full text]