GR03617-01 UDT 2018 Press Pack AW.Indd

Total Page:16

File Type:pdf, Size:1020Kb

GR03617-01 UDT 2018 Press Pack AW.Indd UDT 2018 UNDERSEA DEFENCE TECHNOLOGY SEC, Glasgow Visit us on Stand C2 AVON PROTECTION AT UDT 2018 Avon Protection has more than 130 years of experience, delivering performance innovation, design and engineering solutions. Avon Protection’s capabilities include the design, development, test and manufacture of respirators, filters, escape hoods, powered air purifying respirators (PAPRs), self-contained breathing apparatus (SCBA), hybrid systems, thermal imaging, dive computers and closed circuit rebreathers. Over our history of innovation, design and engineering, we have exclusively focused on the military, law enforcement, firefighting and industrial markets, understanding the unique requirements of these specialist, high threat, user groups. This depth of understanding and specialisation has enabled Avon Protection to become the recognised global market leader for respiratory products in this field. PRODUCTS ON SHOW MCM100 MDC150 Mi-TIC S NH15 COMBO 2 AVON PROTECTION AT UDT 2018 MCM100 The MCM100 is a configurable platform to meet multiple military Underwater Breathing Apparatus (UBA) requirements. It is a fully closed circuit, electronically controlled, mixed gas rebreather CE tested to 100m, suitable for a large range of military or tactical diving disciplines such as Mine Countermeasure (MCM), Explosive Ordnance Disposal (EOD) shallow or deep, Mine Investigation and Exploitation (MIE) and Special Operations Forces (SOF). MDC150 The next generation of military dive computer with real-time data/ decompression logging and a custom interface which is fully reconfigurable allowing reprogramming as requirements change. The multiple algorithm capability allows for end user decompression system inclusion. The robust and ergonomic form has been specifically designed for use in demanding military diving applications. Mi-TIC S. The Mi-TIC S is a premium lightweight thermal imaging camera optimised for naval damage control teams and on-board use. The high performance components, selected to deliver an 1100c degree dynamic range and increased resistance to high temperatures, fully sealed buttons and battery compartment to IP67 and protected thermal sensor, all ensure that the Mi-TIC S is unrivalled in maritime fire-fighting and damage control. NH15 COMBO The NH15 Combo is a revolutionary new carbon monoxide (CO) resistant, super compact CBRN escape hood, based on Avon’s widely acclaimed NIOSH approved NH15. The NH15 Combo offers unsurpassed levels of respiratory protection for escape from hazardous environments, particularly when dangerously high levels of CO are present or likely in combination with other toxic materials and gases such as found in a smoke filled environment. 3 AVON PROTECTION AT UDT 2018 Some of the largest and most significant evolutionary steps were made by the Italian MILITARY DIVING: Navy in the 1930s, effectively taking an escape rebreather, the Davis Submerged Escape Apparatus, and developing it for use by the Decima Flottiglia MAS commando EVOLUTION unit. With the adoption of the rebreather by specialist military units during World War 2, its use began to transition from commercial VS REVOLUTION work and military escape to an ever increase range of mission profiles carried out by specialist units, aka the “Frogmen”. Since their early commercial inception in 1878, rebreathers have changed little in their basic operation and use; absorbing Carbon Dioxide These mission profiles have continued to grow, creating an ever-increasing list of from exhaled breath and injecting Oxygen, ready for the next inhalation capability requirements from the diver, of breath. Over the years, incremental changes have been made to which has driven industry forward. From rebreathers to improve efficiency, duration, ergonomics and functional the basic concept of a Frogman, 8 distinct military dive disciplines have been born; control but fundamentally, these have been evolutions of existing sets. Combat Swimmer; Covert Subsurface Infiltration; Maritime Counter-Terrorism; Submarine Release & Infiltration; Manned Underwater Vehicle Operations; EOD and Clearance; Mine Counter Measures (MCM); and Very Shallow MCM. To support the military diver, industry has responded to each of these disciplines with a specific dive set, able to offer some of the capability for some of the missions but rarely most of the capability for most of the missions, until now. Earlier this year, Avon Protection launched the MCM100, a deep diving (100m CE rated), air and mixed gas, electronic control rebreather. The MCM100 rebreather was designed and developed around the diver, to deliver enhanced multi-role capability in the form of a new long endurance, electronically controlled 4 AVON PROTECTION AT UDT 2018 Mushroom Valves rebreather capable of integrating with a range of military diving applications, in Over-Pressure particular mine warfare and Special Forces, Exhaust Valve MOUTHPIECE including Covert Subsurface Infiltration, Submarine Release & Infiltration and Manned Underwater Vehicle Operations. The launch of the MCM100 heralds INHALE EXHALE a revolutionary change in rebreather COUNTER-LUNG COUNTER-LUNG technology, placing two key elements at the heart of the platform; diver safety and multi-role mission capability. At the core of the MCM100’s innovation is CO2 SCRUBBER GAS SUPPLY DILUTENT DILUTENT its world leading, revolutionary, advanced electronics package, enabling the diver to focus on the task ahead and not the management of the dive or the system. OXYGEN CYLINDER Some of the key features include: PIEZA VALVE ADV n Automated pre-dive sequence reducing pre-dive preparation, start up and maintenance times; n Simple HUD showing system performance, message waiting and system errors; n Redundancy layers and manual control to enhance diver safety; The multi-role design approach and role rebreather, with upgradable and future n On-board decompression monitoring advanced electronics package ingrained proofed technology pathways, representing to manage diver gas mixes and in the MCM100 is synonymous with world leading technology, extended service decompression stops; Avon’s history of innovation, design and life and lower support costs. Consequently, engineering. Avon’s manufacturing it is no surprise that at the beginning of n Full data recording for post dive analysis capabilities are centred on specialist 2018, once the product had been launched, and enhanced diver safety; user groups within the military, law it was announced that Avon Protection n Remote software upgrades and enforcement and firefighting markets, all had been awarded the contract to supply enhancement to ensure through operating in high threat, high risk, dynamic a European Armed Forces with MCM100 life improvement; environments. underwater rebreathers, together with in- service support. n Service and maintenance This depth of understanding and software reducing downtime specialisation has been applied to the and lowering cost of ownership MCM100, ensuring that it is a true multi- Leon Klapwijk, President of Avon Protection, said, “We are extremely excited to be bring to market an underwater diving product with such high levels of innovation. Avon Protection continues to remain at the forefront of technology; we continue to meet the needs of our customers to ensure they remain protected against the continually evolving threat. Leon Klapwijk, President of Avon Protection 5 AVON PROTECTION AT UDT 2018 ADVANCED ELECTRONICS EASY BREATHING n Multiple redundant electronics and n Extremely low work of breathing (WOB). rechargeable batteries. n High-performance open circuit n Advanced digital oxygen sensors with Bailout valve (BOV) as standard. voting logic and ‘bad sensor’ removal. n Automatic diluent gas addition valve. n Moisture tolerant carbon dioxide sensor. n Manual diluent and oxygen gas n Data acquisition facility with Bluetooth bypass valves. capability. n Backlit colour handset with automated OPERATIONAL FLEXIBILITY pre-dive and command based alarms. n High pressure composite cylinders as standard. n Water tolerant breathing circuit and STEALTH TECHNOLOGY water removal systems. n A discreet LED Heads up Display (HUD) n Three carbon dioxide absorbent indicating equipment status. cartridge options. n Low magnetic signature and low noise. n Reduced mission set up time. 6 AVON PROTECTION AT UDT 2018 WHERE TO FIND US Visit us at Stand C2 C2 7 CONTACTS MEDIA Natasha Wellon [email protected] SALES Ryan Claughton [email protected] .
Recommended publications
  • Special Forces' Wear of Non-Standard Uniforms*
    Special Forces’ Wear of Non-Standard Uniforms* W. Hays Parks** In February 2002, newspapers in the United States and United Kingdom published complaints by some nongovernmental organizations (“NGOs”) about US and other Coalition special operations forces operating in Afghanistan in “civilian clothing.”1 The reports sparked debate within the NGO community and among military judge advocates about the legality of such actions.2 At the US Special Operations Command (“USSOCOM”) annual Legal Conference, May 13–17, 2002, the judge advocate debate became intense. While some attendees raised questions of “illegality” and the right or obligation of special operations forces to refuse an “illegal order” to wear “civilian clothing,” others urged caution.3 The discussion was unclassified, and many in the room were not * Copyright © 2003 W. Hays Parks. ** Law of War Chair, Office of General Counsel, Department of Defense; Special Assistant for Law of War Matters to The Judge Advocate General of the Army, 1979–2003; Stockton Chair of International Law, Naval War College, 1984–1985; Colonel, US Marine Corps Reserve (Retired); Adjunct Professor of International Law, Washington College of Law, American University, Washington, DC. The views expressed herein are the personal views of the author and do not necessarily reflect an official position of the Department of Defense or any other agency of the United States government. The author is indebted to Professor Jack L. Goldsmith for his advice and assistance during the research and writing of this article. 1 See, for example, Michelle Kelly and Morten Rostrup, Identify Yourselves: Coalition Soldiers in Afghanistan Are Endangering Aid Workers, Guardian (London) 19 (Feb 1, 2002).
    [Show full text]
  • History of Scuba Diving About 500 BC: (Informa on Originally From
    History of Scuba Diving nature", that would have taken advantage of this technique to sink ships and even commit murders. Some drawings, however, showed different kinds of snorkels and an air tank (to be carried on the breast) that presumably should have no external connecons. Other drawings showed a complete immersion kit, with a plunger suit which included a sort of About 500 BC: (Informaon originally from mask with a box for air. The project was so Herodotus): During a naval campaign the detailed that it included a urine collector, too. Greek Scyllis was taken aboard ship as prisoner by the Persian King Xerxes I. When Scyllis learned that Xerxes was to aack a Greek flolla, he seized a knife and jumped overboard. The Persians could not find him in the water and presumed he had drowned. Scyllis surfaced at night and made his way among all the ships in Xerxes's fleet, cung each ship loose from its moorings; he used a hollow reed as snorkel to remain unobserved. Then he swam nine miles (15 kilometers) to rejoin the Greeks off Cape Artemisium. 15th century: Leonardo da Vinci made the first known menon of air tanks in Italy: he 1772: Sieur Freminet tried to build a scuba wrote in his Atlanc Codex (Biblioteca device out of a barrel, but died from lack of Ambrosiana, Milan) that systems were used oxygen aer 20 minutes, as he merely at that me to arficially breathe under recycled the exhaled air untreated. water, but he did not explain them in detail due to what he described as "bad human 1776: David Brushnell invented the Turtle, first submarine to aack another ship.
    [Show full text]
  • Oxygen Toxicity and CCR/Rebreather Diving
    Home (https://www.diverite.com) Articles (https://www.diverite.com/category/articles/) Oxygen Toxicity and CCR/Rebreather Diving OXYGENOXYGEN TOXICITYTOXICITY ANDAND CCR/RE-CCR/RE- BREATHERBREATHER DIVINGDIVING A couple of years ago I had the privilege of spending five days in Florida with Lamar Hires, the owner of Dive Rite. That was the longest time we have managed to spend togethertogether sincesince hehe ‘certified’‘certified’ meme asas aa fullfull cavecave diverdiver inin 19881988 (I(I hadhad alreadyalready donedone overover 100 exploratory cave dives in Canada). Although I am an Inspiration CCR IT (I have been diving the Inspiration since 2000 and the Megalodon since 2005), I did the full Optima CCR course with Lamar as he had other students to train. During this time Lamar and I had hours to chat and it quickly became apparent that there are serious mistakes being made by rebreather divers as a result of their lack of understanding of oxygen (O2) toxicity in the rebreather diving environment. Lamar asked me to write an article to address some of those mistakes. This article builds on prior articles that I have written on the topic of oxygen toxicity that have appeared on the Dive Rite blog. Oxygen toxicity is a consequence of the biochemical damage that occurs in cells as a result of oxygen free radicals. Whenever oxygen is present, oxygen free radicals are formed. The number of radicals is directly related to the partial pressure of oxygen (pO2). Our cells have several mecha- nisms to inactivate oxygen radicals and to repair the damage that they cause.
    [Show full text]
  • Special Operations Rebreathers
    Special Operations Underwater Life Support Systems INTRODUCTION TO JFD JFD is the world leading underwater capability provider facilitating the commercial and defence diving industries by offering innovative diving, submarine rescue and subsea technical solutions. JFD has a well-established history in the development of advanced and innovative diving and submarine rescue systems spanning over 30 years. Our systems continue to set the president in terms of capability and performance and JFD is relied upon by divers worldwide across both the defence and commercial sectors. Our products and services have been delivered to a large number of countries across all continents. With in-service support established in many of these locations and tailored Integrated Logistics Support (ILS) packages, JFD is able to provide high customer equipment availability, rapid technical support and tailored training packages. 2 | Introduction JFD offers two highly capable underwater life support systems to meet the full mission profile of today’s Special Operations diver. A modular approach enables customisation of the life support system in response to demands across the full operational spectrum. SHADOW ENFORCER The solution for extended duration and deeper diving The lightweight solution for short duration mission mission profiles. profiles. 3 | Offering A common life support platform facilitates a multi-mission capability offering numerous operational and logistic benefits that include: ENHANCED MISSION EFFECTIVENESS • Front and back mount options • Oxygen
    [Show full text]
  • Amphora Multi-Mission Rebreather
    AMPHORA MULTI-MISSION REBREATHER Introduction: √ The AMPHORA rebreather is based on the current FROGS combat swimmer breathing apparatus √ The AMPHORA can be used as a combat swimmers apparatus or as a shallow water Mine Counter Measure (MCM) rig √ The AMPHORA is also designed for use on the SDV General concept: The simple operation of the gas switch allows the user to switch gas during the dive between breathing pure oxygen in closed circuit or nitrox in semi-closed circuit Operating principle The AMPHORA is a closed circuit apparatus in the oxygen dive configuration and is a Constant Mass Flow Injection apparatus (CMI) in the mixed gas dive configuration Description: Specifications: Ø The AMPHORA is based on the combat Ø Dimensions: 415mm (height) x swimmer FROGS apparatus 285mm (width) x 370mm (length) Ø The AMPHORA is made up of two Ø Nominal duration: - Oxygen : A 2.1L components: cyl.provides a dive duration of 240 Ø The chest-mounted unit includes the minutes at 7 meters breathing apparatus with a 2.1L oxygen Ø Mixture : A 2L cyl. with a 60%02- cylinder 40%N2 gives a dive duration of 60 Ø The 2L mixture cylinder is fitted either minutes on the diver’s leg or on the diver’s back Ø Cartridge capacity: 2.5 kg of using the FROGS harness absorbent Ø Another option: 1.5L mixture cylinder Ø Weight (charged): Approx.14.5 Kgs fitted on the cover for the front unit & 5 Kgs for the 2L Mix cylinder and Mix Reg. Ø Buoyancy: Approx. 500g negative Aqua Lung • 2340 Cousteau Court, Vista, CA 92081 • TEL: 760.597.5000 • FAX: 760.597.4914 • www.aqualung.com/military Front Back Technical data: The Amphora is a Constant Mass Flow Injection apparatus (CMI).
    [Show full text]
  • Design Guidelines for Carbon Dioxide Scrubbers I
    "NCSCTECH MAN 4110-1-83 I (REVISION A) S00 TECHNICAL MANUAL tow DESIGN GUIDELINES FOR CARBON DIOXIDE SCRUBBERS I MAY 1983 REVISED JULY 1985 Prepared by M. L. NUCKOLS, A. PURER, G. A. DEASON I OF * Approved for public release; , J 1"73 distribution unlimited NAVAL COASTAL SYSTEMS CENTER PANAMA CITY, FLORIDA 32407 85. .U 15 (O SECURITY CLASSIFICATION OF TNIS PAGE (When Data Entered) R O DOCULMENTATIONkB PAGE READ INSTRUCTIONS REPORT DOCUMENTATION~ PAGE BEFORE COMPLETING FORM 1. REPORT NUMBER 2a. GOVT AQCMCSION N (.SAECIP F.NTTSChALOG NUMBER "NCSC TECHMAN 4110-1-83 (Rev A) A, -NI ' 4. TITLE (and Subtitle) S. TYPE OF REPORT & PERIOD COVERED "Design Guidelines for Carbon Dioxide Scrubbers '" 6. PERFORMING ORG. REPORT N UMBER A' 7. AUTHOR(&) 8. CONTRACT OR GRANT NUMBER(S) M. L. Nuckols, A. Purer, and G. A. Deason 9. PERFORMING ORGANIZATION NAME AND ADDRESS 10. PROGRAM ELEMENT, PROJECT. TASK AREA 6t WORK UNIT NUMBERS Naval Coastal PanaaLSystems 3407Project CenterCty, S0394, Task Area Panama City, FL 32407210,WrUnt2 22102, Work Unit 02 II. CONTROLLING OFFICE NAME AND ADDRE1S t2. REPORT 3ATE May 1983 Rev. July 1985 13, NUMBER OF PAGES 69 14- MONI TORING AGENCY NAME & ADDRESS(if different from Controtling Office) 15. SECURITY CLASS. (of this report) UNCLASSIFIED ISa. OECL ASSI FICATION/DOWNGRADING _ __N•AEOULE 16. DISTRIBUTION STATEMENT (of thia Repott) Approved for public release; distribution unlimited. 17. DISTRIBUTION STATEMENT (of the abstract entered In Block 20, If different from Report) IS. SUPPLEMENTARY NOTES II. KEY WORDS (Continue on reverse side If noceassry and Identify by block number) Carbon Dioxide; Scrubbers; Absorption; Design; Life Support; Pressure; "Swimmer Diver; Environmental Effects; Diving., 20.
    [Show full text]
  • The Closed Circuit Rebreather (CCR): Is It the Safest Device for Deep Scientific Diving?
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Open Marine Archive doi:10.3723/ut.34.031 Underwater Technology, Vol. 34, No. 1, pp. 31–38, 2016 www.sut.org The closed circuit rebreather (CCR): is it the safest device for deep scientific diving? Alain Norro* Royal Belgian Institute for Natural Sciences, Operational Directorate Nature, Gulledelle 100, B-1200 Brussels-Belgium Briefing Technical Received 12 August 2016; Accepted 20 September 2016 Abstract During both World Wars, many improvements were The closed circuit rebreather (CCR) is not a new diving tech- made to rebreathers based on their use for covert nology. From the late 1990s CCR units were commercially military actions. available in Europe, and increasingly more divers, and The first electronic closed circuit rebreather, among them scientific divers, have been trained to use known as the Electrolung, was marketed in 1969. them. Even if many benefits exist for using CCR for all diving However, it was not until the late 1990s when elec- depth ranges, it is in the deep diving zone ranging from tronic CCR started to be sold into the mainstream 50 m to 100 m of sea water where the main advantages to scuba diving markets, with the introduction of the using this equipment exist. Using rebreathers does carry BUDDY-INSPIRATION (now renamed the Ambient additional risks, and these must be mitigated to ensure safe Pressure Diving’s Inspiration CCR range). Modern usage. A standard for CCR scientific diving has existed for CCRs for the European market are made by a small many years in the USA, and the levels of expertise within the number of manufacturers, and their design and European scientific diving community are now sufficient for construction must follow the European Normative a European standard to be established.
    [Show full text]
  • Idstori Diver
    Historical Diver, Number 15, 1998 Item Type monograph Publisher Historical Diving Society U.S.A. Download date 23/09/2021 19:54:03 Link to Item http://hdl.handle.net/1834/30858 IDSTORI DIVER "elf[[[! aik of each "ad" i> thii ~don't die without ha<>ing Conowed, >tofw, pmcha>ed o< made a fzefmd of >o<t>, to gfimf»< fo< youudf thi> n£w wo<td." CWJfiam 'Bufn, "23weath 'Jwpia ~ea>" 1928 Number 15 Spring 1998 Cousteau and Hass An early time line • Dr. Peter B. Bennett • O.S.S. Commemorative Stone • Jerri Lee Cross • • Evolution of the Australian Porpoise Regulator • Rouquayrol Denayrouze in Germany • • General Electric Closed Circuit Deep Diving System • • Bibliophiles • Nick lcom • Gahanna Italian Diving Helmet • HISTORICAL DIVING SOCIETY USA HISTORICAL DIVER MAGAZINE A PUBLIC BENEFIT NONPROFIT CORPORATION ISSN 1094-4516 2022 CLIFF DRIVE #119 THE OFFICIAL PUBLICATION OF SANTA BARBARA, CALIFORNIA 93109 U.S.A. THE HISTORICAL DIVING SOCIETY U.S.A. PHONE: 805-692-0072 FAX: 805-692-0042 DIVING HISTORICAL SOCIETY OF e-mail: [email protected] or HTTP://WWW.hds.org/ AUSTRALIA, S.E. ASIA EDITORS ADVISORY BOARD Leslie Leaney, Editor Dr. Sylvia Earle Dick Long Andy Lentz, Production Editor Dr. Peter B. Bennett 1. Thomas Millington, M.D. CONTRIBUTING EDITORS Dick Bonin Bob & Bill Meistrell Bonnie Cardone E.R. Cross Nick Icorn Scott Carpenter Bev Morgan Peter Jackson Nyle Monday Jeff Dennis John Kane Jim Boyd Dr. Sam Miller Jean-Michel Cousteau Phil Nuytten OVERSEAS EDITORS E.R. Cross Sir John Rawlins Michael Jung (Germany) Andre Galeme Andreas B. Rechnitzer Ph.D.
    [Show full text]
  • America's First Frogman: the Draper Kauffman Story
    Naval War College Review Volume 59 Article 18 Number 2 Spring 2006 America’s First Frogman: The Draper Kauffman Story Robert G. Kaufman Elizabeth Kauffman Bush Follow this and additional works at: https://digital-commons.usnwc.edu/nwc-review Recommended Citation Kaufman, Robert G. and Bush, Elizabeth Kauffman (2006) "America’s First Frogman: The Draper Kauffman Story," Naval War College Review: Vol. 59 : No. 2 , Article 18. Available at: https://digital-commons.usnwc.edu/nwc-review/vol59/iss2/18 This Book Review is brought to you for free and open access by the Journals at U.S. Naval War College Digital Commons. It has been accepted for inclusion in Naval War College Review by an authorized editor of U.S. Naval War College Digital Commons. For more information, please contact [email protected]. Color profile: Disabled Composite Default screen BOOK REVIEWS 175 Kaufman and Bush: America’s First Frogman: The Draper Kauffman Story had spent as much time dissecting the Laurence), Kauffman persevered at the Chavez regime as those that preceded it. Naval Academy despite his poor eye- One of the few drawbacks is that there sight, which nearly prevented him from is little attention to an examination of attending and initially denied him a Hugo Chavez and his inner circle of commission in the Navy when he grad- advisors. uated in 1933. This book is a must-read for anyone Disappointed but undaunted, he ac- who wishes to get beyond Chavez’s cepted a position at a shipping company, rhetoric and red beret. It would enrich U.S.
    [Show full text]
  • Oxygen Content in Semi-Closed Rebreathing Apparatuses for Underwater Use. Measurements and Modeling
    Doctoral Thesis in Technology and Health Stockholm, Sweden 2015 Oxygen content in semi-closed rebreathing apparatuses for underwater use. Measurements and modeling OSKAR FRÅNBERG KTH ROYAL INSTITUTE OF TECHNOLOGY ENGINEERING SCIENCES Oxygen content in semi-closed rebreathing apparatuses for underwater use. Measurements and modeling OSKAR FRÅNBERG Doctoral thesis No. 6 2015 KTH Royal Institute of Technology Engineering Sciences Department of Environmental Physiology SE-171 65, Solna, Sweden ii TRITA-STH Report 2015:6 ISSN 1653-3836 ISRN/KTH/STH/2015:6-SE ISBN 978-91-7595-616-9 Akademisk avhandling som med tillstånd av KTH i Stockholm framlägges till offentlig granskning för avläggande av teknisk doktorsexamen fredagen den 25/9 2015 kl. 09:00 i sal D2 KTH, Lindstedtsvägen 5, Stockholm. iii Messen ist wissen, aber messen ohne Wissen ist kein Wissen Werner von Siemens Å meta e å veta Som man säger på den Kungliga Tekniska Högskolan i Hufvudstaden Att mäta är att väta Som man säger i dykeriforskning Till min familj Olivia, Artur och Filip iv v Abstract The present series of unmanned hyperbaric tests were conducted in order to investigate the oxygen fraction variability in semi-closed underwater rebreathing apparatuses. The tested rebreathers were RB80 (Halcyon dive systems, High springs, FL, USA), IS-Mix (Interspiro AB, Stockholm, Sweden), CRABE (Aqua Lung, Carros Cedex, France), and Viper+ (Cobham plc, Davenport, IA, USA). The tests were conducted using a catalytically based propene combusting metabolic simulator. The metabolic simulator connected to a breathing simulator, both placed inside a hyperbaric pressure chamber, was first tested to demonstrate its usefulness to simulate human respiration in a hyperbaric situation.
    [Show full text]
  • 2011 Thomasville Memorial Day Parade Notes Carolina Piedmont
    Carolina Piedmont Base of the USSVI presents the Issue 1106 June 2011 Inside this issue: 2011 Thomasville Memorial Day Parade Notes Base Contacts 2 There were 24 NC tors was evident as this parade activities. Officer’s Call 3 Subvets at this year‘s parade along with sev- is the only Memorial Also Rudy Hernandez a Base Meeting Minutes 4 eral wives representing Day Parade in North Korean War Congres- the Carolina Piedmont, Carolina. After the pa- sional Medal of Honor Chaplin’s Corner 6 Nat Greene, and Tarheel rade, we set up the pa- recipient was recognized SubVettes 9 Bases. Our 3 Uncle rade submarine and Mk- as part of this year‘s me- Sams made their debut at 14 torpedo as part of a morial program. At the Funnies 10 this parade and will be static display located in 2010 Burnsville meeting CPB Color Guard 12 used again at the two the stadium. Four para- the Carolina Piedmont upcoming Fourth of July troopers dropped from Base made Rudy an hon- XO’s Transmissions 13 parades. The usual good 10,000 feet into the sta- orary submariner. Massing of the Colors 14 turnout of parade specta- dium as part of the post Vet News 18 Retiree Checklist 20 USS Herring SS-233 22 Base Calendar 24 More Parade Pics on Page 23 USSVI Creed To perpetuate the memory of our shipmates who gave their Lost Boats for June lives in the pursuit of duties USS O-9 (SS 70) June 19, 1941 while serving their country. “Sailors, rest your oars” That their dedication, deeds, USS S 27 (SS 132) June 19, 1942 and supreme sacrifice be a USS R 12 (SS 89) June 12, 1943 constant source of motivation USS HERRING (SS 233) June 1, 1944 toward greater accomplish- ments.
    [Show full text]
  • Spearfishing in the South Atlantic Snapper Grouper Fishery
    Spearfishing in the South Atlantic Snapper Grouper Fishery Current Concerns Pertaining to Spearfishing in the South Atlantic EEZ During the March 2018 meeting, the Council heard concerns, primarily from North Carolina, over the impact of spearfishing on grouper populations. Fishermen have requested that the Council consider requiring an endorsement for spearfishing since this component of the fishery appears to be growing. In addition, there are concerns over increasing user conflict between divers using spearfishing gear for commercial harvest of snapper grouper species and commercial hook-and-line fishermen in some areas of North Carolina. The Council requested that the Snapper Grouper Advisory Panel (AP) provide input on the issue. At their April 2018 meeting, the AP provided the following: • Free diving is becoming more popular in North Carolina. Classes are offered to improve efficiency when targeting snapper grouper species with spearfishing gear. • There is mounting concern over the effectiveness of spearfishing resulting in localized depletion of shallow-water groupers. Fishermen are noting an increase in the number of dive boats in some areas. • Hook-and-line gear is relatively inefficient. However, fishermen maintain that this inefficiency has positive effects on the resource. Spearfishing gear, however, is extremely efficient and there is concern it may be taking its toll on already dwindling grouper populations. • Hook-and-line fishermen are increasingly frustrated with having to compete with dive operations. • Similar issues are occurring in south Florida. • Commercial spearfishing results in very little or no discarding, which has a positive effect on the resource. • Use of spearfishing among recreational divers in inshore waters has increased sharply in the last 15 years in north Florida.
    [Show full text]