Section 9: DSP Applications
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
MLT Verification Codes Link the List of MLT Verification (VER) Codes Is Given Here to Assist You in Identifying the Trouble After the MLT Is Performed
MLT Verification Codes Link The list of MLT Verification (VER) Codes is given here to assist you in identifying the trouble after the MLT is performed. VER RESPONSE DESCRIPTION No obvious trouble was detected on the line. However, there may still be a problem with parts of the loop that were not tested. For example, there might be a problem in the station set, on a crossbar line, or in the Central Office (CO). When the system tests ok you 0 TEST OK will see that the DC resistances and voltage will not indicate a problem. The AC signature will be valid (if done), the line ckt will be ok and the system can draw and break dial tone. Balance should be good. VER_05 (zero five) is applicable to all switches and applies to both integrated and universal DLC loops. It indicates that all metallic tests passed, but that the channel test was either not made, didn’t complete in time or the returned results did not match the acceptable signatures. It does not mean that the channel is bad. TEST OK - CHANNEL For IDLC in 5ESS switches, it may be an indication that there may 05 NOT TESTED be a shortage of transmission test facility (TTF) responders. (The TTF performs the ISLC channel tests). This VER Code applies to the LTF, LTS, DCTU and CMU test heads. With this VER Code, the RSA may be able to arrange a front end close out as no trouble affecting the loop has been identified. NOTE: Length of loop is not given with this Ver code. -
Vpisystems—Demonstration Examples
Appendix VPIsystems—Demonstration Examples Introduction The following 12 examples have been added to demonstrate important engineering aspects of Chapter 3. The user can play with each example in real time by accessing the website http://www.vpiphotonics.com/VPIplayer.php. This particular website is maintained by VPIsystems GmbH and it is provided at no cost to the user. Any difficulties opening the website or any software improperly functioning should be addressed directly to VPIsystems GmbH, Carnotstr. 6, 10587 Berlin, Germany, Phone +49 30 398 058-0, Fax +49 30 398 058-58 Application Example 1 Title System impairments in 10 Gbps NRZ-based WDM transmissions Description This setup illustrates the impact of ASE noise and fiber nonlinearities on the performance of a 10 Gbps NRZ-based WDM system. The BER of each channel can be investigated individually. The user can adjust the number of spans (transmission length), switch off/on the fiber nonlinear- ities and modify the EDFA noise figure. Application Example 2 Title Performance of NRZ, RZ, and Duobinary modulation format in 10 Gbps transmission Description The setup compares the performance of the NRZ, RZ, and Duobinary modulation formats in a single channel 10 Gbps transmission. The BER obtained with each modulation format are displayed against the accumulated dispersion or the OSNR. The user can adjust the OSNR (respectively the accumulated dispersion) as well as the 3 dB bandwidth of the optical filter in front of the receiver. S. V. Kartalopoulos, Next Generation Intelligent Optical Networks, 257 C Springer 2008 258 Appendix: VPIsystems—Demonstration Examples Application Example 3 Title Performance comparison of NRZ, DPSK, and DQPSK in 40 Gbps transmission Description The setup investigates the performance of NRZ, DPSK, and DQPSK modulation in a single channel 40 Gbps transmission. -
Multi-Frequency Modulation and Control for DC/AC and AC/DC Resonant Converters
University of Tennessee, Knoxville TRACE: Tennessee Research and Creative Exchange Doctoral Dissertations Graduate School 12-2018 Multi-Frequency Modulation and Control for DC/AC and AC/DC Resonant Converters Chongwen Zhao University of Tennessee, [email protected] Follow this and additional works at: https://trace.tennessee.edu/utk_graddiss Recommended Citation Zhao, Chongwen, "Multi-Frequency Modulation and Control for DC/AC and AC/DC Resonant Converters. " PhD diss., University of Tennessee, 2018. https://trace.tennessee.edu/utk_graddiss/5269 This Dissertation is brought to you for free and open access by the Graduate School at TRACE: Tennessee Research and Creative Exchange. It has been accepted for inclusion in Doctoral Dissertations by an authorized administrator of TRACE: Tennessee Research and Creative Exchange. For more information, please contact [email protected]. To the Graduate Council: I am submitting herewith a dissertation written by Chongwen Zhao entitled "Multi-Frequency Modulation and Control for DC/AC and AC/DC Resonant Converters." I have examined the final electronic copy of this dissertation for form and content and recommend that it be accepted in partial fulfillment of the equirr ements for the degree of Doctor of Philosophy, with a major in Electrical Engineering. Daniel Costinett, Major Professor We have read this dissertation and recommend its acceptance: Fred Wang, Leon M. Tolbert, D. Caleb Rucker Accepted for the Council: Dixie L. Thompson Vice Provost and Dean of the Graduate School (Original signatures are on file with official studentecor r ds.) Multi-Frequency Modulation and Control for DC/AC and AC/DC Resonant Converters A Dissertation Presented for the Doctor of Philosophy Degree University of Tennessee, Knoxville Chongwen Zhao December 2018 To my parents To Junting Guo ii Acknowledgement I would like to acknowledge the support and guidance from faculty members and staff at the University of Tennessee. -
Solid State Relays Are Ideally Suited for Use in Flammable Surroundings, and in Environments with High Electrical and Magnetic Noise
Clare Overview Clare is a wholly owned subsidiary of IXYS Corporation, and is conveniently located close to Boston, Massachusetts, USA. Clare designs, manufactures, and markets a wide variety of semiconductor devices, and is a major designer and manufacturer of optically isolated electronic products. Clare manufactures one of the industry’s broadest lines of Solid State Relays (SSR), featuring galvanic input-to-output electrical isolation from 1500Vrms up to 5000Vrms; a wide selection of optocouplers and linear optocouplers; and optically isolated AC Power Switches. Clare SSR products are rapidly replacing electromechanical relays in many applications, making it a leading supplier to the Telecommunications, Medical, Security, Utility Metering, and Industrial Control industries. Replacing electromechanical relays with smaller, more-reliable optically isolated SSRs improves safety and lowers costs, while minimizing equipment size and enhancing overall system performance. With no moving parts, no coils, and no contacts, Solid State Relays are ideally suited for use in flammable surroundings, and in environments with high electrical and magnetic noise. For the Telecommunications Industry, Clare manufactures a broad range of products that includes phone-line interface and monitoring devices, DC Termination devices for xDSL and ISDN applications, and Central Office products. Clare’s newest entries into the Central Office market include several new Line Card Access Switch devices with high transient immunity: 1500V/ms. These robust devices have led to the development of monolithic high voltage switching ICs, powered from 3.3V digital supplies, that interface to industrial controls, instrumentation, automatic test equipment, and medical applications (see the new CPC7514). Clare’s expertise in high-voltage and power devices supports a growing line of standard devices. -
Telecom Acronym Guide
Telecom Acronym Guide Fourth Edition Telecom Acronym Guide Fourth Edition Numerics ACAC Actual Call Admission Control 2F Two-fiber ACEG Alternating Current Equipment Ground 10 GbE 10 Gigabit Ethernet ACK Acknowledge 10 GFC 10 Gigabit Fibre Channel (Same as FC1200) ACL Active Control List; Access Control List 100G 100 Gigabits ACO Alarm Cutoff 16-QAM 16 (points) Quadrature Amplitude Modulation ACQ Acquire 3D Three-dimensional ACR Allowed Cell Rate 3G Third Generation ACS Automatic Channel Shutdown; Alarm Correlation and Suppression 3GPP Third Generation Partnership Project ACSE Association Control Service Element 40G 40 Gigabits ACSS Automatic Channel Shutdown Suppression; 4C Consortium of Intel, IBM, Matsushita, and Toshiba Automatic Channel Shutdown State 4F Four-fiber ACT Active 4G Fourth Generation ADC Analog-to-Digital Converter; Add/Drop Coupler 5C Consortium of Intel, Sony, Matsushita, Toshiba, ADI Asset Distribution Interface and Hitachi ADM Add/Drop Multiplexer 5G Fifth Generation ADP Actual Departure Potential; Automatic A Data Processing ADSL Asymmetric Digital Subscriber Line A/D Analog-to-digital ADT Actual Departure Time; Automatic AAL ATM Adaptation Layer Data Transmission AAL0 ATM Adaptation Layer Type 0 AE Automation Engine; Automation Environment A AL1 ATM Adaptation Layer Type 1 AES Advanced Encryption Standard; AAL2 ATM Adaptation Layer 2 Transport Application Environment Specific AAL3/4 ATM Adaptation Layer Types 3 and 4 AESA ATM End System Address; ATM End Station AAL5 ATM Adaptation Layer 5 Address ABR Available Bit -
Chapter 1: Modulation Systems
SYLLABUS: 141304 – ANALOG AND DIGITAL COMMUNICATION L T P C 3 1 0 4 UNIT I FUNDAMENTALS OF ANALOG COMMUNICATION 9 Principles of Amplitude Modulation – AM Envelope – Frequency Spectrum and Bandwidth – Modulation Index and Percent Modulation – AM Voltage Distribution – AM Power Distribution – Angle Modulation – FM and PM Waveforms – Phase Deviation and Modulation Index – Frequency Deviation and Percent Modulation – Frequency Analysis of Angle Modulated Waves – Bandwidth Requirements for Angle Modulated Waves. UNIT II DIGITAL COMMUNICATION 9 Basics – Shannon Limit for Information Capacity – Digital Amplitude Modulation – Frequency Shift Keying – FSK Bit Rate and Baud – FSK Transmitter – BW Consideration of FSK – FSK Receiver – Phase Shift Keying – Binary Phase Shift Keying – QPSK – Quadrature Amplitude Modulation – Bandwidth Efficiency – Carrier Recovery – Squaring Loop – Costas Loop – DPSK. UNIT III DIGITAL TRANSMISSION 9 Basics – Pulse Modulation – PCM – PCM Sampling – Sampling Rate – Signal to Quantization Noise Rate – Companding – Analog and Digital – Percentage Error – Delta Modulation – Adaptive Delta Modulation – Differential Pulse Code Modulation – Pulse Transmission – Intersymbol Interference – Eye Patterns. UNIT IV DATA COMMUNICATIONS 9 Basics – History of Data Communications – Standards Organizations for Data Communication – Data Communication Circuits – Data Communication Codes – Error Control – Error Detection – Error Correction – Data Communication Hardware – Serial and Parallel Interfaces – Data Modems – Asynchronous Modem – Synchronous Modem – Low-Speed Modem – Medium and High Speed Modem – Modem Control. UNIT V SPREAD SPECTRUM AND MULTIPLE ACCESS TECHNIQUES 9 Basics – Pseudo-Noise Sequence – DS Spread Spectrum with Coherent Binary PSK – Processing Gain – FH Spread Spectrum – Multiple Access Techniques – Wireless Communication – TDMA and CDMA in Wireless Communication Systems – Source Coding of Speech for Wireless Communications. L: 45 T: 15 Total: 60 TEXT BOOKS 1. -
Visvesvarayatechnologic
P a g e | 1 VISVESVARAYA TECHNOLOGICAL UNIVERSITY Belgaum, Karnataka-590014 A Project Report On “IMPLEMENTATION OF SPACE VECTOR PULSE WIDTH MODULATION FOR INVERTERS USING MATLAB AND SIMULINK” Submitted in partial fulfilment for the award of degree of Bachelor of Engineering In Electronics and Communication Engineering 2018-2019 Submitted by AKHIL CHOWDARY M 1NH15EC005 BUJJA AJAY 1NH15EC012 T S HIMAKEERTHI 1NH15EC121 Under the Guidance of Dr. K C R NISHA Professor Department of Electronics and Communication Engineering, NHCE P a g e | 2 DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING CERTIFICATE Certified that the project work “IMPLEMENTATION OF SPACE VECTOR PULSE WIDTH MODULATION FOR INVERTERS USING MATLAB AND SIMULINK” carried out by the following Bonafide students of New Horizon College of Engineering in partial fulfilment for the award of Bachelor of Engineering In Electronics and Communication branch , of Visvesvaraya TechnologicalUniversity , Belgaum during the academic year 2018-2019. It is certified that all corrections /suggestions indicated for internal assessment have been approved as it satisfies the academic requirements with respect of project work prescribed for said degree. 1. AKHIL CHOWDARY M 1NH15EC005 2. BUJJA AJAY 1NH15EC012 3. T.S. HIMAKEERTHI 1NH15EC121 Internal Guide HOD Principal Dr. K C R NISHA Dr. SANJEEV SHARMA Dr. MANJUNATHA External Viva Name of the Examiners: Signature with date: 1. 2. P a g e | 3 ACKNOWLEDGEMENT The satisfaction that accompanies the successful completion of task would be incomplete without mention of the people who made it possible, whose constant guidance and encouragement crown all efforts with success. We express my sincere gratitude to Dr. Sanjeev Sharma, Head of Department of Electronics and Communication Engineering, New Horizon College of Engineering, for providing guidance and encouragement. -
Gradually Introduced Efficiencies Into the Traditional Loop Architecture, Such As Digital Loop Carrier
gradually introduced efficiencies into the traditional loop architecture, such as digital loop carrier ("DLC") systems at the remote terminal that used multiplexers and other electronics and the addition ofhigh-~ap_a<;ity feeder plant, in order to enhance the transmission functionality ofthe loop to better accommodate voice service. Even with significant gains in technology that greatly improved the efficiencies for transmitting voice service, however, the traditional ILEC loop architecture could only support transmission rates of56 kpbs (nominally) in best-case configurations. 12. As consumer demand for bandwidth-rich data services grows, the inherent constraints in the ll..ECs' traditional loop architecture have caused the ll..ECs to explore and implement a "next generation" architecture that better utilizes the full transmission functionality ofboth the low and high frequencies ofthe local loop in order to provide a wider range of telecommunications services to a broader cross-section ofend-users. In particular, I discuss how the ll..ECs have enhanced their loops by incorporating a much greater use offiber, introducing splitting and additional multiplexing functions at remote terminals and additional demultiplexing functions at the central office and elsewhere. These loop enhancements have made it possible to greatly increase and improve the transmission functionality ofthe loop. Indeed, the introduction ofnext-generation architecture permits ll..ECs and their data affiliates to provide a whole host of new services, and higher-quality existing services, to their customers while also increasing the ll..ECs' own economies in their loop plant. 13. I also explain that the transmission functionality provided in next generation RT architecture is no different than that the transmission functionality delivered in a more traditional DLC architecture. -
DSLAM (Digital Subscriber Line Access Multiplexer)
DSLAM (Digital Subscriber Line Access Multiplexer) Faster connections to the Internet from phone lines are possible through a Digital Subscriber Line Access Multiplexer (abbreviated to DSLAM). The role of this network device is located in the telephone exchanges of providers for the services. The service works by taking advantage of the multiplexing techniques used to connect several Digital Subscriber Lines to a high speed connection which they share. These can be placed along remote areas to provide DSL services to once out of reach locations. These additions may be costly to the telephone companies, but it allows them to receive more subscribers to their services, as they would be able to take advantage of DSL services now available in their area. The DSLAM equipment at the local telephone company will collect data from several modem ports and multiplexes the synchronized composite signal of both voice information and connection data. The DSLAMmoves the connections over to DSL lines which are processed through an Asynchronous Transfer Mode, a Frame Relay or the Internet Protocol Network. This traffic is routed through the backbone switch through an Access Network which connects through the Internet Backbone. The DSLAM is designed to simply network the connections as appropriate and provides an access point between the customer and the ISP. The DSLAM may have enhanced capabilities which may allow for the monitoring of bandwidth consumption by each customer as well as providing compensation for bandwidth leeching through setting bandwidth speed caps for certain connections. Not all DSLAM locations are capable of this function. DSLAMs are not only used for Internet connections; several hotels, lodges and residential areas as well as businesses utilize them to have their own private telephone exchange or specialized network. -
Local-Loop and DSL Testing Reference Guide DSL Cover.Qxd: Cover NEXT-GEN.1AN 5/7/07 10:46 AM Page 4
DSL_Cover.qxd: Cover NEXT-GEN.1AN 5/7/07 10:46 AM Page 3 Local-Loop and DSL Testing Reference Guide DSL_Cover.qxd: Cover NEXT-GEN.1AN 5/7/07 10:46 AM Page 4 About EXFO EXFO is a recognized test and measurement expert in the global telecommunications industry through the design and manufacture of advanced and innovative solutions as well as best-in-class customer support. The Telecom Division, which represents the company’s main business activity, offers fully integrated and complete test solutions to network service providers, system vendors and component manufacturers in approximately 70 countries. One of EXFO’s strongest competitive advantages is its PC/Windows- based modular platforms that host a wide range of tests across optical, physical, data and network layers, while maximizing technology reuse across several market segments. The Life Sciences and Industrial Division mainly leverages core telecom technologies to offer value-added solutions in the life sciences and high-precision assembly sectors. For more information about EXFO, visit www.EXFO.com. About the Authors Robert Fitts attended the University of Guelph and is an Electronics Engineering (Telecommunications) Technology graduate of Fleming College near Toronto, Canada. As EXFO’s Vice-President, Product Management, Copper Access business unit, Mr. Fitts has been an active participant in the field of local-loop testing, DSL, IPTV and VoIP. Mr. Fitts has nearly 25 years of direct experience in the telecommunications testing industry. Chris Dunford is an Electronics Engineering Technology graduate of Fleming College near Toronto, Canada. He is currently Product Manager for EXFO’s Copper Access business unit. -
Loopcare Verification Codes (0-99)
LoopCare Verification Codes (0-99) • VER 0: TEST OK • VER 0A: TEST OK • VER 0B: CPE or HIGH RESISTANCE OPEN • VER 0C: CPE or HIGH RESISTANCE OPEN • VER 0D: OPEN IN OR DSL TERM • VER 0E: OPEN OUT BALANCED OR DSL TERM • VER 0H: ROH DETECTED DURING TEST • VER 0L: NO FAULTS TO BENCHMARKED LENGTH • VER 0M: TEST OK MTU • VER 0P: PROBABLY TEST OK • VER 0R: TEST OK • VER 0T: OUT OF TOLERANCE CONDITION • VER 05: TEST OK - CHANNEL NOT TESTED • VER 6: BUSY-SPEECH • VER 11: CROSS TO WORKING PAIR- FAULT • VER 12: AC FEMF FAULT • VER 13: HAZARDOUS POTENTIAL • VER 14: CROSS TO WORKING PAIR: MARGINAL • VER 15: DC FEMF MARGINAL • VER 16: AC FEMF MARGINAL • VER 17: RESISTIVE FAULT AND DC FEMF • VER 18: OPEN OUT AND CROSS • VER 21: GROUND FAULT • VER 22: SHORT FAULT • VER 23: SWINGING RESISTANCE: FAULT • VER 24: SWINGING RESISTANCE: MARGINAL • VER 25: SHORT AND GROUND • VER 26: MDF TEST RECOMMENDED- LOW RESISTANCE • VER 27: DC RESISTANCE- MARGINAL • VER 28: SHORT OR GROUND • VER 3: OPEN IN • VER 30: SWITCH COMMON EQUIP BAD • VER 31: INVALID LINE CIRCUIT • VER 32: CANNOT DRAW DIAL TONE • VER 33: CAN'T BREAK DIAL TONE • VER 34: POSSIBLE INVALID ACCESS • VER 35: OPEN IN AND CROSS • VER 36: LINE CIRCUIT AND DIAL TONE PROBLEM • VER 37: DIAL TONE BURST DETECTED • VER 38: POSSIBLE CO WIRING ERROR • VER 39: CO EQUIP BAD - ISTF BAD - LINE CARD BAD - PROTOCOL HANDLER BAD • VER 40: CO EQUIP SUSPECT • VER 41: OPEN OUT BALANCED • VER 42: OPEN OUT IN CABLE • VER 43: HIGH RESISTANCE OPEN • VER 44: OPEN OUT 2-PARTY OR BRIDGE LIFTERS • VER 45: OPEN OUT - NEAR DROP • VER -
201014052 Release Date: 4/9/2010 Third Party Communication: None Date of Communication: Not Applicable
INTERNAL REVENUE SERVICE NATIONAL OFFICE TECHNICAL ADVICE MEMORANDUM November 23, 2009 Number: 201014052 Release Date: 4/9/2010 Third Party Communication: None Date of Communication: Not Applicable Index (UIL) No.: 165.01-00, 165.07-00 CASE-MIS No.: TAM-119625-09 Team Manager ---------------- ---------------------------------------------------- --------------------------------------- Taxpayer's Name: ------------------------------------------------------ Taxpayer's Address: -------------------------- ---------------- -------------------------------------- Taxpayer's Identification No ---------------- Year(s) Involved: ------- Date of Conference: ------------------ LEGEND: Taxpayer = ------------------------------------------------------ ---------- = --------------------------------------- ------- A = ----------- ------- B = ------------ ------- C = --------------- ------- D = ------------------- Year 1 = ------- Year 2 = ------------------- Year 3 = ------------------- Tracking System = ---------------------------------------------- ISSUE: What is the "single, identifiable property" by reference to which casualty losses incurred by Taxpayer, a telecommunications company, as a result of ----------------- should be 2 determined under § 165 of the Internal Revenue Code and the corresponding regulations? CONCLUSION: For this purpose, it is reasonable to treat the central office building in a telecommunications wire center as a single, identifiable property; the central office equipment inside a wire center building ("central office equipment")