Every Pump Operator's Basic Equation Continuing Education Course Every Pump Operator’s Basic Equation BY PAUL SPURGEON TRAINING THE FIRE SERVICE FOR 135 YEARS To earn continuing education credits, you must successfully complete the course examination. The cost for this CE exam is $25.00. For group rates, call (973) 251-5055. Every Pump Operator’s Basic Equation Educational Objectives On completion of this course, students will 1. Learn how to develop a proper fire stream 3. Describe two friction loss formulas used by fire departments 2. Define friction loss and explain two ways water flows 4. Learn how elevation must be calculated into fire stream through hoses calculations BY PAUL SPURGEON water after it leaves the nozzle until it reaches its final destina- tion, which is usually the seat of the fire.A s the streams are HE EQUATION EP = NP + FL + APP + ELEV IS THE being produced, they are affected by the discharge pressure, basic equation every pump operator needs to calculate nozzle design, and nozzle setting. A discharge pressure that is T when operating the fire pump.T oday, many pump pan- too strong not only will be very hard to handle but will also els have flow meters that allow the pump operator to match break up into smaller droplets, which aren’t as effective in the readout on the pump panel with the gallon-per-minute extinguishing the fire.A discharge that is too weak may not be (gpm) flow of the selected nozzle.T his is a disservice to the delivering enough gpm to overcome the British thermal units integrity of the pump operator. A knowledgeable operator (Btus) being produced by the fire.A n adequate stream also needs to understand how a proper fire stream is developed needs to have the reach to be able to hit the seat of the fire. and how each part is applied. Only with this knowledge can After the water leaves the nozzle, the stream is also affected the pump operator go from being a knob puller who sets by nature in the forms of gravity and wind. The stream needs predetermined figures on a gauge to an efficient engineer ca- to be strong enough to overcome these factors. There has to pable of filling the hoselines with the proper amount of water be enough reach so the firefighters don’t have to be in the not only to extinguish fires but also to keep crews safe on the absolute hottest environment. If the stream falls short of the fireground. fire, it cannot extinguish the fire. If the stream isn’t capable Each figure can be calculated using simple math. How the of overcoming the wind, it may not be possible to place the concepts are developed is explained below. The engine pres- water on the seat of the fire, where it is needed. sure is calculated by plugging numbers into each figure and adding or subtracting them. StanDARD PRESSURES • EP = Engine Pressure The fire service uses three standard nozzle pressures.T hese • NP = Nozzle Pressure standards are derived from years of trial and error and experi- • FL = Friction Loss ence. The nozzle pressure can be adjusted upward to deliver • Elev = Elevation Loss or Gain more gpm flow or downward to make the line more maneuver- • App = Appliance Friction Loss able. Unfortunately, we can’t have both. If the nozzle pressure Some figures may be used more than once; others may not is increased, a few more gpm can be delivered, but the hoseline be used at all. If more than one size of hose is used, you will will become stiffer and harder to handle. There is even a point have to figure friction loss for each size.T his also applies if where the pressure becomes so great that the turbulence in multiple appliances are used or if hoselines are laid both up the stream prevents the producing of a working fire stream. If and down a hill. The pump operator needs to account for the nozzle pressure is decreased, the hoseline will be easier to each of these figures each time a hoseline is pulled from the handle but at the expense of lower gpm. The standards give apparatus. a good compromise for delivering the best of both worlds. To extinguish the fire while being able to maneuver the hoseline, NOZZLE PRESSURE the following nozzle pressures have been adopted: To be called a fire stream, a hoseline needs to have a nozzle • Smooth bore handline: 50 pounds per square inch (psi). attached to its end. This nozzle gives the stream its shape, • Fog nozzle handline: 100 psi. reach, and velocity. By definition, a fire stream is a stream of • Smooth bore master stream: 80 psi. www.FireEngineeringUniversity.com PUMP OP EQuatION ● These standards give us a good basic starting point in figur- ing the overall engine pressure. Table 1. Expansion and Temperature Temperature (ºF) Expansion Ratio SMOOTH BORE NOZZLES 212º 1,700 to 1 A smooth bore nozzle is simply a tube that narrows down 500º 2,400 to 1 to an opening with a specific inside diameter.A s the water gets narrowed through the nozzle, it develops its smooth solid 1,200º 4,200 to 1 stream. In the late 1890s, John R. Freeman1 conducted experi- ments designed to define what a good solid stream is. He came up with four requirements that are still used today: Figure 1. Laminar Flow A stream that has not lost its continuity by breaking into 1showers or a spray. A stream that shoots nine-tenths of the whole volume of 2 water inside a 15-inch-diameter circle and three-fourths of its volume into a 10-inch-diameter circle at its break-over point. A stream stiff enough to attain, under fair conditions, the 3named height or distance, even through a breeze. A stream that, with no wind blowing, will enter a room Figure 2. Turbulent Flow 4 through a window and strike the ceiling with enough force to splatter well. These standards give a good foundation for building a good quality fire stream.2 DISCHARGE As we know, it is not the pressure of a stream that extin- guishes a fire but the amount of water in gpm that cools a fire. Note that I did not say solid stream when referring to The officer in charge of a fire needs to determine the amount the pattern setting. At the narrowest pattern, a fog nozzle of water needed to extinguish the fire and choose the appropri- still produces a fog stream. It consists of tiny water droplets ate hoseline and nozzle that will deliver the correct gpm. Large discharged in a uniform direction toward the fire.T he small fires make for good news coverage, but in reality they happen water droplets, if applied properly, will absorb the heat faster because the firefighters were unable to place enough water at than a solid stream. This is because there is more surface the seat of the fire to overcome the Btus being produced.T he area with all of the droplets compared with a solid stream. officer as well as the pump operator need to know the gpm Another advantage of having tiny water droplets is that they flow from different nozzle tips to know how much fire each quickly turn into steam. When a fire is in an enclosed space, a can extinguish. As a general rule, the maximum nozzle diameter relatively small amount of fog stream can be shot into the area should not exceed one-half of the size of the hose to which it (the area is sealed tight), and the water will turn into steam is attached—for example, a 2½-inch handline should not have a smothering the fire.T his is called the indirect attack method. smooth bore nozzle any larger than 1¼ inches. A 1¾-inch hand- Its advantage is that it uses relatively small amounts of water. 7 line should have a nozzle tip no larger than ⁄8 inch. This helps in preventing water damage to the structure. This The amount of water discharging from a smooth bore is method of attacking fire was first developed by Chief Lloyd determined by the nozzle pressure and the inside diameter of Layman while he was in the U.S. Coast Guard. When water the opening. The formula for determining the gpm flow from turns to steam, it expands. The amount of expansion is deter- a smooth bore nozzle is as follows: mined by the amount of heat in the room. Note: The indirect attack is used only in enclosed spaces 29.72D2√P (D = nozzle diameter; √P = square root of pressure) where there is no possibility of life in the room. The steam will burn and kill anyone inside the environment. If there is a pos- For example, a one-inch smooth bore tip will have a dis- sibility that someone is in the room, including firefighters, use a charge of 210 gpm: 29.72 × 12 × 7.07 = 210 gpm. fog pattern in conjunction with proper ventilation. As the water is turned into steam, it will cool the burning material, but the FOG NOZZLES steam has to be allowed to escape to the outside. A close-up Many fire departments have chosen to place combination fire attack must be coordinated with proper ventilation. Table 1 fog nozzles on their apparatus. They feel that it is important shows the amount of expansion at various temperatures. to have the option of delivering a stream that can be adjusted from a straight stream to a wide fog pattern.
Recommended publications
  • Wildland Fire Incident Management Field Guide
    A publication of the National Wildfire Coordinating Group Wildland Fire Incident Management Field Guide PMS 210 April 2013 Wildland Fire Incident Management Field Guide April 2013 PMS 210 Sponsored for NWCG publication by the NWCG Operations and Workforce Development Committee. Comments regarding the content of this product should be directed to the Operations and Workforce Development Committee, contact and other information about this committee is located on the NWCG Web site at http://www.nwcg.gov. Questions and comments may also be emailed to [email protected]. This product is available electronically from the NWCG Web site at http://www.nwcg.gov. Previous editions: this product replaces PMS 410-1, Fireline Handbook, NWCG Handbook 3, March 2004. The National Wildfire Coordinating Group (NWCG) has approved the contents of this product for the guidance of its member agencies and is not responsible for the interpretation or use of this information by anyone else. NWCG’s intent is to specifically identify all copyrighted content used in NWCG products. All other NWCG information is in the public domain. Use of public domain information, including copying, is permitted. Use of NWCG information within another document is permitted, if NWCG information is accurately credited to the NWCG. The NWCG logo may not be used except on NWCG-authorized information. “National Wildfire Coordinating Group,” “NWCG,” and the NWCG logo are trademarks of the National Wildfire Coordinating Group. The use of trade, firm, or corporation names or trademarks in this product is for the information and convenience of the reader and does not constitute an endorsement by the National Wildfire Coordinating Group or its member agencies of any product or service to the exclusion of others that may be suitable.
    [Show full text]
  • TFT Guide to Nozzles
    CONTENTS 10 COMMON QUESTIONS ABOUT AUTOMATIC EVOLUTION OF FIRE STREAMS.......................................................2 NOZZLES EVOLUTION OF COMBINATION NOZZLES......................................3 1) How is an automatic nozzle different from a regular (conventional) UNDERSTANDING FIRE NOZZLE DESIGN ......................................5 nozzle? LIMITATIONS OF CONVENTIONAL NOZZLES.................................6 2) How does an automatic nozzle work? AUTOMATIC NOZZLES INVENTED................................................ 10 3) What pressure do we pump to automatic nozzles? BENEFITS OF AUTOMATIC NOZZLES .......................................... 13 4) How do I know how much water I am flowing? SLIDE VALVE vs. BALL VALVE ..................................................... 16 5) What is the flow from each "Click Stop" on the nozzle? TRAINING CONSIDERATIONS WITH AUTOMATICS .................... 18 6) Can I use automatics with foam and foam eductors? USING LARGER SIZE ATTACK LINES .......................................... 21 7) Why don't all automatic nozzles have spinning teeth? 8) What type of nozzle is best for “Nozzleman Flow Control?” BOOSTER TANK OPERATIONS..................................................... 22 SHAPING THE FIRE STREAM PATTERN ...................................... 23 9) Is it true that the stream from a "SOLID" bore nozzle hits harder and goes farther than the "Hollow”' stream from a fog nozzle? SMOOTH BORE vs. FOG TIP .......................................................... 24 FLUSHING DEBRIS.........................................................................
    [Show full text]
  • ENGINE COMPANY OPERATIONS Second Edition
    FIRE AND RESCUE DEPARTMENTS OF NORTHERN VIRGINIA FIREFIGHTING AND EMERGENCY OPERATIONS MANUAL ENGINE COMPANY OPERATIONS Second Edition Issued: November 2003 Revised: December 2013 Engine Company Operations, Second Edition Final Version, December 2013 ACKNOWLEDGEMENTS Engine Company Operations was developed through a cooperative effort of the following Northern Virginia fire departments: . City of Alexandria . Loudoun County . Arlington County . City of Manassas . City of Fairfax . Marine Corps Base Quantico . Fairfax County . Metropolitan Washington Airports . Fauquier County Authority (MWAA) . Fort Belvoir . Prince William County . Fort Myer . Stafford County The Northern Virginia Fire Operations Board managed the development of the first edition of the manual (released in November 2003) and the current second edition. The first edition content was developed by the Operations Board’s Technical Writing Group. The following members of the Firefighting and Emergency Operations Technical Writing Workgroup participated in the third edition revision of the manual in 2012 and 2013: City of Alexandria: Lieutenant Dave Bogozi, Lieutenant Matthew Craig City of Manassas: Battalion Chief Mark Nary Arlington County: Captain David Santini, Captain Nick Krechting Fairfax City: Captain Joseph Schumacher, Captain Gregory Thuot Fairfax County: Battalion Chief Tyrone Harrington, Captain David Barlow, Captain Dan Shaw, Master Technician Matthew Tamillow Fort Belvoir: Lieutenant Kevin Good Fort Myer: Assistant Chief Bruce Surette, Captain William Long Loudoun
    [Show full text]
  • 25 Pointers for Your Engine Company by JEFF SHUPE
    Continuing Education Course 25 Pointers for Your Engine Company BY JEFF SHUPE Program supported through an educational grant provided by: TRAINING THE FIRE SERVICE FOR 134 YEARS To earn continuing education credits, you must successfully complete the course examination. The cost for this CE exam is $25.00. For group rates, call (973) 251-5055. 25 Pointers for your engine company Educational Objectives On completion of this course, students will: ● Describe the limits of various hoseline sizes and the appropri- ● Gain an understanding of the importance of apparatus posi- ate size for specific fires using the acronym “ADULTS” tioning in terms of hoseline stretching ● Describe proper nozzle operating techniques ● Gain an understanding of the importance of proper hoseline pressure and flow B Y J E F F S H U P E building. it is a narrow street, and cars line both sides. the officer in charge of the first-due engine radios, “We have a 1 onsider this scenario: it is a midday summer working fire in a large 2 ⁄2-story frame. Well involved!” 1 afternoon, and a large 2 ⁄2-story, wood-frame structure the two firefighters in the company start to stretch the C is on fire. it is a double-decker style two-family dwell- initial attack hose. the older, senior firefighter knows the situ- ing that has been vacant for a short time. Fire is coming out of ation and “has been there” many times before. he starts to lay all windows and doors on both floors and the attic.t he smoke out the 2½-inch attack line.
    [Show full text]
  • Home & Land Owners
    HOME & LAND OWNERS URBAN | WILDLAND INTERFACE FIRE PROTECTION EQUIPMENT LNCURTIS.COM WATER FLOW IMPORTANT: Fighting fires should be performed by trained fire fighters only. PREPARATION PREVENTION DEFENSIBLE SPACE CALL 911 Intermountain Division Serving Colorado, Southern Idaho, Montana, Eastern Nevada, Utah and Wyoming 1635 Gramercy Road Salt Lake City, UT 84104 phone: 800-426-0509 fax: 801-487-1278 [email protected] Northwest Division Serving Alaska, Northern Idaho, Oregon and Washington 6507 South 208th Street Kent, WA 98032 phone: 800-426-6633 fax: 253-236-2997 [email protected] Pacific Division Serving California, Hawaii and Nevada 1800 Peralta Street Oakland, CA 94607 phone: 800-443-3556 fax: 510-839-5325 [email protected] Southwest Division Serving Arizona and New Mexico 4647 South 33rd Street Phoenix, AZ 85040 phone: 877-453-3911 fax: 602-453-3910 [email protected] facebook.com/ToolsForHeroes @ToolsForHeroes Tools for Heroes® courtesy https://www.nfpa.org/Public-Education/Fire-causes-and-risks/Wildfire/Preparing-homes-for-wildfire HOME & LAND OWNERS URBAN | WILDLAND INTERFACE FIRE PROTECTION EQUIPMENT PREPARATION PREVENTION DEFENSIBLE SPACE CALL 911 Informative resources for urban wildland interface readiness programs: U.S FOREST SERVICE https://www.fs.usda.gov/rmrs/ living-fire-how-social-scientists-are- photo courtesy Colorado State Forest Service helping-wildland-urban-interface- communities-reduce-wildfire NATIONAL FIRE The collection of product herein is designed to help the home and PROTECTION ASSOCIATION land
    [Show full text]
  • Wildland Fire Equipment 2019
    DEFENSE LOGISTICS AGENCY Wildland Fire Equipment 2020 DLA Wildfire Equipment Ordering - 2020 ABOUT THE DEFENSE LOGISTICS AGENCY (DLA) WILDFIRE EQUIPMENT PROGRAM. The program is available to all Department of Forestry and Fire Management (DFFM) Cooperators who have a current Intergovernmental Agreement (IGA). The catalog items aren’t stocked in our facility but are ordered and in most cases shipped direct from DLA Supply Depots. EQUIPMENT PROGRAM FAQ WHO CAN ORDER FROM THIS PROGRAM? All DFFM Cooperators who have a current Intergovernmental Agreement. WHY ORDER FROM THIS PROGRAM? While not trying to compete with the private sector fire equipment providers, the prices are generally lower. Also, the equipment is part of a National Fire Equipment System (NFES) which means if you damage or destroy a DLA acquired item, it can be replaced on an incident where a Supply Unit has been set up and stocked. DO THE PRICES CHANGE FROM WHAT IS IN THE CURRENT CATALOG? Yes but not often. As prices change the order form price list is updated and posted to the website. Check the date of your order form against the date on the website. Remember there is a 10% handling charge your order. This covers the admin cost of having the program available in Arizona. DOES THE PERSONAL PROTECTIVE EQUIPMENT MEET NFPA 1977 STANDARDS? Yes. Shirts, Pants, gloves, helmets, shrouds, fire shelters all meet the NFPA Standard. WHAT IF I ACCIDENTLY ORDER THE WRONG SIZE OR WRONG ITEM? CAN I RETURN IT? Possibly. If the item must be returned to DLA there is a 25% re-stocking charge.
    [Show full text]
  • Planning a Hose and Nozzle System for Effective Operations by Jay Comella, Lieutenant Oakland Fire Department
    By firefighters, for firefighters Firenuggets.com Planning a Hose and Nozzle System for Effective Operations By Jay Comella, Lieutenant Oakland Fire Department The Oakland (Calif.) Fire Department (OFD) convened a Board of Inquiry to investigate the line-of-duty- death of Firefighter Tracy Toomey, who died on January 10, 1999. The fire building at 3052 Broadway was a two-story, balloon-frame building of mixed occupancy, with a residential area over the commercial premises. It was not an unusual building for Oakland. On arrival, the first-alarm companies encountered a heavy fire condition on the first floor with extension up the stairway. They made an aggressive interior attack using multiple 1½-inch handlines. Fire was not extinguished in time to prevent the loss of structural integrity. The resulting collapse of the second floor into the first floor killed one OFD member and left two others with career-ending injuries. One of the three direct causes the Board of Inquiry report cited for the line-of- duty death was the inability of 1½-inch hose to flow sufficient water to extinguish the heavy volume of fire encountered. (1) Left to right: automatic nozzle (50-350 gpm), adjustable-gallonage nozzle (30-60- The report further recommended using 1¾-inch hose to 90-125 gpm @ 100 psi), constant-gallonage remedy insufficient fire flow volume of the 1½-inch hose. nozzle (150 gpm @ 50 psi), and 15/16-inch By simply upgrading from 1½-inch to 1¾-inch hose, the smooth-bore nozzle (180 gpm @ 50 psi). OFD could eliminate fully one-third of the direct causes (Photos by Daryl Liggins.) cited by the Board of Inquiry.
    [Show full text]
  • FIREFIGHTING PRODUCT CATALOGUE Scottyfire.Com TABLE of CONTENTS
    FIREFIGHTING PRODUCT CATALOGUE scottyfire.com TABLE OF CONTENTS BACKPACKS Bravo Backpack 4 Alpha Backpack 5 Hand pumps 6 FOAM & GEL SYSTEMS Foam Eductor Backpack system 7 Roll & Foam Mobile Foam system 8 Foam Factory/Fire Gel kits 10 Foam Applicator Kits 11 Foam-Fast ™ 12 Foam Eductors 13 Foam Mixing Systems 14 NOZZLES Air Aspirating Foam Nozzles 16 Fog/Straight Stream Nozzles 18 Smooth Bore Nozzles 20 Mini Monitor systems 21 WRENCHES Hydrant/Spanner/Drum and Pail 22 ADAPTERS, CONNECTORS & VALVES Water Thief 24 3-Way Valves 25 Squall Wall™ 25 Adapters/Connectors/Reducers 26 ¼ Turn Quick Connectors 27 Pistol Grip Ball Shut Off 28 FIREFIGHTING EXTRAS Pillow Tanks 29 ¾” Forestry Hose winder 30 Rope Throw Bag 30 First Aid Kit 30 All threaded items are available in NPSH, NHT or BSP thread. Please specify when ordering. GRP refers to Glass-reinforced plastic. It is a composite material of fibre-reinforced polymer. 2 scottyfire.com SCOTTY FIREFIGHTER Scotty Firefighter 1 800 214 0141 3 BACKPACKS • Transparent window for label (display crew BRAVO BACKPACK A 4002B Bravo Backpack (front) • Ultra-comfortable method to carry liquids name/number). 4' hose with quick connect used during fire fighting operations. • Backpack has a capacity of 6 gallons B 4062 • Consists of a Cordura® high-visibility yellow (22 L), weighs approximately 50lbs (22.7 kg) C 4000 Water hand pump outer shell with a replaceable flexible when full. Dimensions (empty) 24” H x 20” W. D 4002B Bravo Backpack (back) inner bladder. • 4” filling opening includes removable debris • 3" wide fully padded and adjustable shoulder screen and lid with retaining strap.
    [Show full text]
  • Fireterminology.Pdf
    Abandonment: Abandonment occurs when an emergency responder begins treatment of a patient and the leaves the patient or discontinues treatment prior to arrival of an equally or higher trained responder. Abrasion: A scrape or brush of the skin usually making it reddish in color and resulting in minor capillary bleeding. Absolute Pressure: The measurement of pressure, including atmospheric pressure. Measured in pound per square inch absolute. Absorption: A defensive method of controlling a spill by applying a material that absorbs the spilled material. Accelerant: Flammable fuel (often liquid) used by some arsonists to increase size or intensity of fire. Accelerator: A device to speed the operation of the dry sprinkler valve by detecting the decrease in air pressure resulting in acceleration of water flow to sprinkler heads. Accountability: The process of emergency responders (fire, police, emergency medical, etc...) checking in as being on-scene during an incident to an incident commander or accountability officer. Through the accountability system, each person is tracked throughout the incident until released from the scene by the incident commander or accountability officer. This is becoming a standard in the emergency services arena primarily for the safety of emergency personnel. Adapter: A device that adapts or changes one type of hose thread, type or size to another. It allows for connection of hoses and pipes of incompatible diameter, thread, or gender. May contain combinations, such as a double-female reducer. Adapters between multiple hoses are called wye, Siamese, or distributor. Administrative Warrant: An order issued by a magistrate that grants authority for fire personnel to enter private property for the purpose of conducting a fire prevention inspection or similar purpose.
    [Show full text]
  • Fire Pro Monitor/Nozzle Catalog
    Manufacturers of Fire Protection Equipment Since 1937 MONITOR/NOZZLE CATALOG Fire Pro Division 2015 FIRE PRO FIRE PROTECTION EQUIPMENT THAT HITS THE MARK Fire Pro, manufacturer of high-flow monitors and nozzles, together with Potter Roemer, the industry leader in fire protection equipment, provides an all-encompassing line of fire protection equipment and accessories. Products are backed by Potter Roemer's history of quality engineering since 1937. Since its inception in 1979, Fire Pro's mission, “To manufacture quality products at an affordable price with short, reliable lead times” still holds true, making Fire Pro a successful division of Potter Roemer. Monitors and nozzles from Potter Roemer Fire Pro are essential in mining industries, oil refineries, and petrochemical settings for fire protection, dust abatement, cleaning, and many other uses requiring precise high-flow water delivery. Whether it's a standard, modified, or a custom product for a specific application, Fire Pro takes pride in delivering with personalized customer service, tailored design and engineering. Fire Pro works with the customer's location and need to design anything, whether it's a modification to an existing product or a one-of-a-kind design for a specific application. Because every product should hit the mark in function, reliability, and pricing. CONTENTS MONITORS NOZZLES FOAM Manual/Station ..................... 4 Direct Connect ..................... 22 Foam Trailers & Tanks ........... 28 Brass .................................. 10 Fog ...................................
    [Show full text]
  • Module 8: Water Use Topic 1
    Module 8: Water Use Topic 1: Introduction Module introduction Narration Script: Water can be a good friend on the fireline, and you’ll want to take care of that precious commodity and use it wisely. You may have to bring the water to the scene of the fire yourself using a backpack pump. Or, water or agents may be available from an engine or from another water source by way of a portable pump. In that case, you’ll be using hoses and nozzles to attack the flames. Hoses can make fire fighting easier, but you’ll need to be proficient at simple and progressive hose lays. And your choice of nozzle to put on the end of that hose will vary according to the fire environment you’re facing. If you’re thinking there’s a lot to learn about spraying water or foam on a fire, you’re right. That’s why it calls for an entire water delivery system. Module overview Spraying water or foam on a fire may seem like one of the more fun parts of wildland fire fighting. However, before the water comes out of the hose, there are some basics you’ll need to be familiar with, including the: • “Ins” and “outs” of backpack pumps • Tools of the trade—hose, nozzles, and hose-related equipment • Types of hose lays—simple and progressive • Hand signals specific to water use • Types of fire streams—fog and straight • Hose and equipment maintenance Narration Script: Water, water everywhere—well, that’s not exactly true on the fireline.
    [Show full text]
  • Wildland Fire Equipment 2019 Visit Us on the Web At: Wildland Fire Equipment Products from DLA
    DEFENSE LOGISTICS AGENCY Wildland Fire Equipment 2019 Visit us on the Web at: https://www.fedmall.mil/ Wildland Fire Equipment Products from DLA We are proud to present this special catalog spotlighting wildland fire equipment Contents available from FedMall. From hand tools to protective gear, FedMall offers a variety of products that carry our service guarantees: About This Catalog ........................................ 2 • Easy Requisitions – See It. Buy It. Get It • Flexible – Featuring Multiple Ordering Options • Reliable – Delivering the ProductsYou Need,WhereYou Need Them Wildland Fire Equipment • Anywhere – Assuring Global Delivery Hand Tools ................................................................................... 4 • Anytime – Supporting 24/7 Purchasing Sheaths .......................................................................................... 5 • More – Offering Extensive Product Selection Handles and Handle Wedges ..................................................... 5 • Safe – Providing Easy Compliance Hoses and Gaskets ....................................................................... 6 The items in this publication are also available online. Visit us at: Water-Handling Accessories ...................................................... 7 https://www.fedmall.mil Pumps and Accessories ............................................................ 11 Chainsaw Accessories ............................................................... 13 Fuel Storage ...............................................................................
    [Show full text]