Wildland Fire Incident Management Field Guide

Total Page:16

File Type:pdf, Size:1020Kb

Wildland Fire Incident Management Field Guide A publication of the National Wildfire Coordinating Group Wildland Fire Incident Management Field Guide PMS 210 April 2013 Wildland Fire Incident Management Field Guide April 2013 PMS 210 Sponsored for NWCG publication by the NWCG Operations and Workforce Development Committee. Comments regarding the content of this product should be directed to the Operations and Workforce Development Committee, contact and other information about this committee is located on the NWCG Web site at http://www.nwcg.gov. Questions and comments may also be emailed to [email protected]. This product is available electronically from the NWCG Web site at http://www.nwcg.gov. Previous editions: this product replaces PMS 410-1, Fireline Handbook, NWCG Handbook 3, March 2004. The National Wildfire Coordinating Group (NWCG) has approved the contents of this product for the guidance of its member agencies and is not responsible for the interpretation or use of this information by anyone else. NWCG’s intent is to specifically identify all copyrighted content used in NWCG products. All other NWCG information is in the public domain. Use of public domain information, including copying, is permitted. Use of NWCG information within another document is permitted, if NWCG information is accurately credited to the NWCG. The NWCG logo may not be used except on NWCG-authorized information. “National Wildfire Coordinating Group,” “NWCG,” and the NWCG logo are trademarks of the National Wildfire Coordinating Group. The use of trade, firm, or corporation names or trademarks in this product is for the information and convenience of the reader and does not constitute an endorsement by the National Wildfire Coordinating Group or its member agencies of any product or service to the exclusion of others that may be suitable. PREFACE The Wildland Fire Incident Management Field Guide is a revision of what used to be called the Fireline Handbook, PMS 410-1. This guide has been renamed because, over time, the original purpose of the Fireline Handbook had been replaced by the Incident Response Pocket Guide, PMS 461. As a result, this new guide is aimed at a different audience, and it was felt a new name was in order. Purpose0B The Wildland Fire Incident Management Field Guide states, references, or supplements wildland fire incident management and operational standards established by the National Wildfire Coordinating Group (NWCG). Relationship1B to the Incident Response Pocket Guide and Emergency Responder Field Operations Guide This field guide contains some information that is duplicated in the Incident Response Pocket Guide (IRPG) and the Department of Homeland Security, Federal Emergency Management Agency (FEMA), National Incident Management System Emergency Responder Field Operating Guide (ERFOG), but the documents have different purposes and user groups. This field guide is the standard NWCG incident management reference guide. The IRPG is the “wildland fire job aid and training reference for operational personnel from Firefighter Type 2 through Division Supervisor and Initial Attack/Extended Attack Incident Commander,” and is primarily an initial responder’s tool. The ERFOG “provides guidance designed to assist emergency response personnel in the use of the National Incident Management System (NIMS) Incident Command System (ICS) during incident operations” and is primarily a Command and General Staff tool. Revision2B Process This field guide will be revised every 5 years. To recommend changes to the document, contact your agency representative on the Operations and Workforce Development Committee (OWDC). Information about this committee is located on the NWCG Web site at http://www.nwcg.gov. The field guide is available electronically and is formatted for printing on standard 8½ x 11-inch paper. Wildland Fire Incident Management Field Guide i ii Wildland Fire Incident Management Field Guide TABLE OF CONTENTS PREFACE ........................................................................................................................................ i Purpose0B ......................................................................................................................................... i Relationship1B to the Incident Response Pocket Guide and Emergency Responder Field Operations Guide ......................................................................................................................... i Revision2B Process .......................................................................................................................... i TABLE OF CONTENTS ............................................................................................................... iii CHAPTER 1 – FIREFIGHTING SAFETY .................................................................................... 1 Risk Management ....................................................................................................................... 1 Tenets of a High Reliability Organization .................................................................................. 1 Wildland Fire Safety Culture ...................................................................................................... 2 Wildland Fire Safety Principles .................................................................................................. 3 Clothing and Personal Protective Equipment ............................................................................. 3 Fatigue – Work and Rest............................................................................................................. 4 Nutrition and Hydration .............................................................................................................. 4 Driving Limitations ..................................................................................................................... 5 Smoke Impairment of Roads: Assessment and Response ......................................................... 5 Carbon Monoxide Poisoning ...................................................................................................... 7 Injury and Fatality Procedures .................................................................................................... 9 Serious Injury .......................................................................................................................... 9 Fatality .................................................................................................................................... 9 Burn Injury Procedures ............................................................................................................. 10 Night Operations ....................................................................................................................... 11 Personnel Transportation .......................................................................................................... 11 Firing Equipment ...................................................................................................................... 11 Chain Saws................................................................................................................................ 12 Incident-Generated Hazmat ...................................................................................................... 12 Media Access Guidelines .......................................................................................................... 13 General Policy ....................................................................................................................... 13 Guidelines ............................................................................................................................. 13 Safety Responsibilities of Wildland Fire Supervisors .............................................................. 15 General Responsibilities ....................................................................................................... 15 CHAPTER 2 – OPERATIONAL GUIDES .................................................................................. 17 Initial Attack ............................................................................................................................. 17 Wildland Fire Incident Management Field Guide iii Definition of Initial Attack .................................................................................................... 17 Characteristics of an Initial Attack Incident (Type 4 And Type 5 Incidents) ....................... 17 Example of Initial Attack Organization (Type 4 Incident) ................................................... 18 Duties of an Initial Attack Incident Commander .................................................................. 18 Assessing Incident Progress .................................................................................................. 20 Updating Incident Status ....................................................................................................... 20 Fire Suppression Strategies ................................................................................................... 21 Initial Attack Safety Checklist .............................................................................................. 22 Extended Attack ........................................................................................................................ 23 Definition of Extended Attack .............................................................................................
Recommended publications
  • Human Health Risk Assessment of Wildland Fire-Fighting Chemicals: Long-Term Fire Retardants
    HUMAN HEALTH RISK ASSESSMENT OF WILDLAND FIRE-FIGHTING CHEMICALS: LONG-TERM FIRE RETARDANTS Prepared for: Fire and Aviation Management U.S. Forest Service By: Headquarters: 1406 Fort Crook Drive South, Suite 101 Bellevue, NE 68005 September 2017 Health Risk Assessment: Retardants September 2017 EXECUTIVE SUMMARY HEALTH RISK ASSESSMENT OF WILDLAND FIRE-FIGHTING CHEMICALS: LONG-TERM FIRE RETARDANTS September 2017 The U.S. Forest Service uses a variety of fire-fighting chemicals to aid in the suppression of fire in wildlands. These products can be categorized as long-term retardants, foams, and water enhancers. This chemical toxicity risk assessment of the long-term retardants examined their potential impacts on fire-fighters and members of the public. Typical and maximum exposures from planned activities were considered, as well as an accidental drench of an individual in the path of an aerial drop. This risk assessment evaluates the toxicological effects associated with chemical exposure, that is, the direct effects of chemical toxicity, using methodologies established by the U.S. Environmental Protection Agency. A risk assessment is different from and is only one component of a comprehensive impact assessment of all types of possible effects from an action on health and the human environment, including aircraft noise, cumulative impacts, physical injury, and other direct or indirect effects. Environmental assessments or environmental impact statements pursuant to the National Environmental Policy Act consider chemical toxicity, as well as other potential effects to make management decisions. Each long-term retardant product used in wildland fire-fighting is a mixture of individual chemicals. The product is supplied as a concentrate, in either a wet (liquid) or dry (powder) form, which is then diluted with water to produce the mixture that is applied during fire-fighting operations.
    [Show full text]
  • The Art of Reading Smoke for Rapid Decision Making
    The Art of Reading Smoke for Rapid Decision Making Dave Dodson teaches the art of reading smoke. This is an important skill since fighting fires in the year 2006 and beyond will be unlike the fires we fought in the 1900’s. Composites, lightweight construction, engineered structures, and unusual fuels will cause hostile fires to burn hotter, faster, and less predictable. Concept #1: “Smoke” is FUEL! Firefighters use the term “smoke” when addressing the solids, aerosols, and gases being produced by the hostile fire. Soot, dust, and fibers make up the solids. Aerosols are suspended liquids such as water, trace acids, and hydrocarbons (oil). Gases are numerous in smoke – mass quantities of Carbon Monoxide lead the list. Concept #2: The Fuels have changed: The contents and structural elements being burned are of LOWER MASS than previous decades. These materials are also more synthetic than ever. Concept #3: The Fuels have triggers There are “Triggers” for Hostile Fire Events. Flash point triggers a smoke explosion. Fire Point triggers rapid fire spread, ignition temperature triggers auto ignition, Backdraft, and Flashover. Hostile fire events (know the warning signs): Flashover: The classic American Version of a Flashover is the simultaneous ignition of fuels within a compartment due to reflective radiant heat – the “box” is heat saturated and can’t absorb any more. The British use the term Flashover to describe any ignition of the smoke cloud within a structure. Signs: Turbulent smoke, rollover, and auto-ignition outside the box. Backdraft: A “true” backdraft occurs when oxygen is introduced into an O2 deficient environment that is charged with gases (pressurized) at or above their ignition temperature.
    [Show full text]
  • Active Extensional Faults in the Central-Eastern Iberian Chain, Spain
    ISSN (print): 1698-6180. ISSN (online): 1886-7995 www.ucm.es/info/estratig/journal.htm Journal of Iberian Geology 38 (1) 2012: 127-144 http://dx.doi.org/10.5209/rev_JIGE.2012.v38.n1.39209 Active extensional faults in the central-eastern Iberian Chain, Spain Fallas activas extensionales en la Cordillera Ibérica centro-oriental J.L. Simón*, L.E. Arlegui, P. Lafuente, C.L. Liesa Dpt. Ciencias de la Tierra, Facultad de Ciencias, Universidad de Zaragoza, c/ Pedro Cerbuna 12, E-50009 Zaragoza, Spain [email protected], [email protected], [email protected], [email protected] *Corresponding author Received: 27/06/2011 / Accepted: 29/02/2012 Abstract Among the conspicuous extensional structures that accommodate the onshore deformation of the Valencia Trough at the central- eastern Iberian Chain, a number of large faults show evidence of activity during Pleistocene times. At the eastern boundary of the Jiloca graben, the Concud fault has moved since mid Pliocene times at an average rate of 0.07-0.08 mm/y, while rates from 0.08 to 0.33 mm/y have been calculated using distinct stratigraphic markers of Middle to Late Pleistocene age. A total of nine paleoseisms associated to this fault have been identified between 74.5 and 15 ka BP, with interseismic periods ranging from 4 to 11 ka, estimated coseismic displacements from 0.6 to 2.7 m, and potential magnitudes close to 6.8. The other master faults of the Jiloca graben (Ca- lamocha and Sierra Palomera faults) have also evidence of Pliocene to Late Pleistocene displacement, with average slip rates of 0.06 and 0.11-0.15 mm/y, respectively.
    [Show full text]
  • Gao-13-684, Wildland Fire Management
    United States Government Accountability Office Report to Congressional Requesters August 2013 WILDLAND FIRE MANAGEMENT Improvements Needed in Information, Collaboration, and Planning to Enhance Federal Fire Aviation Program Success GAO-13-684 August 2013 WILDLAND FIRE MANAGEMENT Improvements Needed in Information, Collaboration, and Planning to Enhance Federal Fire Aviation Program Success Highlights of GAO-13-684, a report to congressional requesters Why GAO Did This Study What GAO Found The Forest Service and Interior The Department of Agriculture’s Forest Service and the Department of the contract for aircraft to perform various Interior have undertaken nine major efforts since 1995 to identify the number and firefighting functions, including type of firefighting aircraft they need, but those efforts—consisting of major airtankers that drop retardant. The studies and strategy documents—have been hampered by limited information Forest Service contracts for large and collaboration. Specifically, the studies and strategy documents did not airtankers and certain other aircraft, incorporate information on the performance and effectiveness of firefighting while Interior contracts for smaller aircraft, primarily because neither agency collected such data. While government airtankers and water scoopers. reports have long called for the Forest Service and Interior to collect aircraft However, a decrease in the number of performance information, neither agency did so until 2012 when the Forest large airtankers, from 44 in 2002 to 8 in Service began a data collection effort. However, the Forest Service has collected early 2013—due to aging planes and several fatal crashes—has led to limited data on large airtankers and no other aircraft, and Interior has not initiated concerns about the agencies’ ability to a data collection effort.
    [Show full text]
  • Cub Creek 2 Fire Evening Update July 17, 2021 Evening Okanogan-Wenatchee National Forest
    Cub Creek 2 Fire Evening Update July 17, 2021 Evening Okanogan-Wenatchee National Forest Fire Information Line – (541)-670-0812 (8:00 am to 8:00 pm) Winthrop, WA — Cub Creek 2 – Extended attack of the Cub Creek 2 Fire continued today with retardant drops from large air tankers, water scooping/dropping planes, helicopters with buckets and various ground forces of hand crews and engines. The fire burned vigorously throughout the day on Washington Department of Natural Resource and Okanogan County Fire District 6 protected lands and also the Okanogan-Wenatchee National Forest. The majority of the left flank of the fire is lined with dozer line from the heel of the fire to First Creek Road which ties into Forest Road 140 leading to Buck Lake. The north flank remains unchecked at this time. The northeast flank is backing down toward West Chewuch Road where it had crossed north of the junction of the East and West Chewuch Road to Heaton Homestead. The fire is also located east of Boulder Creek Road and is burning towards the north being pushed by diurnal winds. Northwest Incident Management Team 8 assumed management of the fire this evening at 6 p.m. Tonight, a night shift of firefighters include a 20-person handcrew, five engines, and multiple overhead. The Washington State structure strike team has been reassigned to protect properties in the Cub Creek 2 Fire. 8 Mile Ranch is the designated staging area. Evacuation Information: The Okanogan County Emergency Management (OCEM) evacuations for the Chewuch River drainage effected by the Cub Creek 2 Fire remain.
    [Show full text]
  • Smoke Alarms in US Home Fires Marty Ahrens February 2021
    Smoke Alarms in US Home Fires Marty Ahrens February 2021 Copyright © 2021 National Fire Protection Association® (NFPA®) Key Findings Smoke alarms were present in three-quarters (74 percent) of the injuries from fires in homes with smoke alarms occurred in properties reported homei fires in 2014–2018. Almost three out of five home with battery-powered alarms. When present, hardwired smoke alarms fire deathsii were caused by fires in properties with no smoke alarms operated in 94 percent of the fires considered large enough to trigger a (41 percent) or smoke alarms that failed to operate (16 percent). smoke alarm. Battery-powered alarms operated 82 percent of the time. Missing or non-functional power sources, including missing or The death rate per 1,000 home structure fires is 55 percent lower in disconnected batteries, dead batteries, and disconnected hardwired homes with working smoke alarms than in homes with no alarms or alarms or other AC power issues, were the most common factors alarms that fail to operate. when smoke alarms failed to operate. Of the fire fatalities that occurred in homes with working smoke Compared to reported home fires with no smoke alarms or automatic alarms, 22 percent of those killed were alerted by the device but extinguishing systems (AES) present, the death rate per 1,000 reported failed to respond, while 11 percent were not alerted by the operating fires was as follows: alarm. • 35 percent lower when battery-powered smoke alarms were People who were fatally injured in home fires with working smoke present, but AES was not, alarms were more likely to have been in the area of origin and • 51 percent lower when smoke alarms with any power source involved in the ignition, to have a disability, to be at least 65 years were present but AES was not, old, to have acted irrationally, or to have tried to fight the fire themselves.
    [Show full text]
  • Respirator Usage by Wildland Firefighters
    United States Department of Agriculture Fire Forest Service Management National Technology & Development Program March 2007 Tech Tips 5200 0751 1301—SDTDC Respirator Usage by Wildland Firefighters David V. Haston, P.E., Mechanical Engineer Tech Tip Highlights ß Based on a 7-year comprehensive study by the National Wildfire Coordinating Group (NWCG), a 1997 consensus conference concluded that routine use of air purifying respirators (APRs) should not be required. ß APRs provide protection against some, but not all harmful components of wood smoke, and may expose firefighters to higher levels of unfiltered contaminants, such as carbon monoxide. In addition, APRs do not protect firefighters against superheated gases and do not supply oxygen. ß Firefighters may use APRs on a voluntary basis if certain conditions are met. Introduction All firefighters, fire management officers, and safety personnel should understand the issues related to using air purifying respirators (APRs) in the wildland firefighting environment. This Tech Tip is intended to provide information regarding the regulatory requirements for using APRs, how APRs function, and the benefits and risks associated with their use. Respirator Types and Approvals Respirators are tested and approved by the National Institute for Occupational Safety and Health (NIOSH) in accordance with 42 CFR Part 84 (Approval of Respiratory Protection Devices). Respirators fall into two broad classifications: APRs that filter ambient air, and atmosphere-supplying respirators that supply clean air from another source, such as self-contained breathing apparatus (SCBA). APRs include dust masks, mouthpiece respirators (used for escape only), half- and full-facepiece respirators, gas masks, and powered APRs. They use filters or cartridges that remove harmful contaminants when air is passed through the air-purifying element.
    [Show full text]
  • Wildland Firefighter Smoke Exposure
    ❑ United States Department of Agriculture Wildland Firefighter Smoke Exposure EST SERVIC FOR E Forest National Technology & 1351 1803 October 2013 D E E P R A U RTMENT OF AGRICULT Service Development Program 5100—Fire Management Wildland Firefighter Smoke Exposure By George Broyles Fire Project Leader Information contained in this document has been developed for the guidance of employees of the U.S. Department of Agriculture (USDA) Forest Service, its contractors, and cooperating Federal and State agencies. The USDA Forest Service assumes no responsibility for the interpretation or use of this information by other than its own employees. The use of trade, firm, or corporation names is for the information and convenience of the reader. Such use does not constitute an official evaluation, conclusion, recommendation, endorsement, or approval of any product or service to the exclusion of others that may be suitable. The U.S. Department of Agriculture (USDA) prohibits discrimination in all its programs and activities on the basis of race, color, national origin, age, disability, and where applicable, sex, marital status, familial status, parental status, religion, sexual orientation, genetic information, political beliefs, reprisal, or because all or part of an individual’s income is derived from any public assistance program. (Not all prohibited bases apply to all programs.) Persons with disabilities who require alternative means for communication of program information (Braille, large print, audiotape, etc.) should contact USDA’s TARGET Center at (202) 720-2600 (voice and TDD). To file a complaint of discrimination, write USDA, Director, Office of Civil Rights, 1400 Independence Avenue, S.W., Washington, D.C.
    [Show full text]
  • Fire Service Features of Buildings and Fire Protection Systems
    Fire Service Features of Buildings and Fire Protection Systems OSHA 3256-09R 2015 Occupational Safety and Health Act of 1970 “To assure safe and healthful working conditions for working men and women; by authorizing enforcement of the standards developed under the Act; by assisting and encouraging the States in their efforts to assure safe and healthful working conditions; by providing for research, information, education, and training in the field of occupational safety and health.” This publication provides a general overview of a particular standards- related topic. This publication does not alter or determine compliance responsibilities which are set forth in OSHA standards and the Occupational Safety and Health Act. Moreover, because interpretations and enforcement policy may change over time, for additional guidance on OSHA compliance requirements the reader should consult current administrative interpretations and decisions by the Occupational Safety and Health Review Commission and the courts. Material contained in this publication is in the public domain and may be reproduced, fully or partially, without permission. Source credit is requested but not required. This information will be made available to sensory-impaired individuals upon request. Voice phone: (202) 693-1999; teletypewriter (TTY) number: 1-877-889-5627. This guidance document is not a standard or regulation, and it creates no new legal obligations. It contains recommendations as well as descriptions of mandatory safety and health standards. The recommendations are advisory in nature, informational in content, and are intended to assist employers in providing a safe and healthful workplace. The Occupational Safety and Health Act requires employers to comply with safety and health standards and regulations promulgated by OSHA or by a state with an OSHA-approved state plan.
    [Show full text]
  • A Preparedness Guide for Firefighters and Their Families
    A Preparedness Guide for Firefighters and Their Families JULY 2019 A Preparedness Guide for Firefighters and Their Families July 2019 NOTE: This publication is a draft proof of concept for NWCG member agencies. The information contained is currently under review. All source sites and documents should be considered the authority on the information referenced; consult with the identified sources or with your agency human resources office for more information. Please provide input to the development of this publication through your agency program manager assigned to the NWCG Risk Management Committee (RMC). View the complete roster at https://www.nwcg.gov/committees/risk-management-committee/roster. A Preparedness Guide for Firefighters and Their Families provides honest information, resources, and conversation starters to give you, the firefighter, tools that will be helpful in preparing yourself and your family for realities of a career in wildland firefighting. This guide does not set any standards or mandates; rather, it is intended to provide you with helpful information to bridge the gap between “all is well” and managing the unexpected. This Guide will help firefighters and their families prepare for and respond to a realm of planned and unplanned situations in the world of wildland firefighting. The content, designed to help make informed decisions throughout a firefighting career, will cover: • hazards and risks associated with wildland firefighting; • discussing your wildland firefighter job with family and friends; • resources for peer support, individual counsel, planning, and response to death and serious injury; and • organizations that support wildland firefighters and their families. Preparing yourself and your family for this exciting and, at times, dangerous work can be both challenging and rewarding.
    [Show full text]
  • Global Military Helicopters 2015-16 Market Report Contents
    GLOBAL MILITARY HELICOPTERS 2015-16 MARKET REPORT CONTENTS MARKET OVERVIEW 2 MILITARY HELICOPTER KEY REQUIREMENTS 4 EUROPE 5 NORTH AMERICA 10 LATIN AMERICA & THE CARIBBEAN 12 AFRICA 15 ASIA-PACIFIC 16 MIDDLE EAST 21 WORLD MILITARY HELICOPTER HOLDINGS 23 EUROPE 24 NORTH AMERICA 34 LATIN AMERICA & THE CARIBBEAN 36 AFRICA 43 ASIA-PACIFIC 49 MIDDLE EAST 59 EVENT INFORMATION 65 Please note that all information herein is subject to change. Defence IQ endeavours to ensure accuracy wherever possible, but errors are often unavoidable. We encourage readers to contact us if they note any need for amendments or updates. We accept no responsibility for the use or application of this information. We suggest that readers contact the specific government and military programme offices if seeking to confirm the reliability of any data. 1 MARKET OVERVIEW Broadly speaking, the global helicopter market is currently facing a two- pronged assault. The military helicopter segment has been impacted significantly by continued defense budgetary pressures across most traditional markets, and a recent slide in global crude oil prices has impacted the demand for new civil helicopters as well as the level of activity for existing fleets engaged in the offshore oil & gas exploration sector. This situation has impacted industry OEMs significantly, many of which had been working towards strengthening the civil helicopter segment to partially offset the impact of budgetary cuts on the military segment. However, the medium- to long-term view of the market is promising given the presence of strong fundamentals and persistent, sustainable growth drivers. The market for military helicopters in particular is set to cross a technological threshold in the form of next-generation compound helicopters and tilt rotorcraft.
    [Show full text]
  • Landscape Fire Crisis Mitigation
    FIRE-IN FIre and REscue Innovation Network Thematic Working Group Vegetation Fires EC 20171127 1 | F IRE-IN has received funding from the European Union’s Horizon 2020 Research and Innovation programme under grant agreement N°740 575 Main Activities Objective main lines: (i) Identification and harmonisation of operational Improve the National capability gaps and European Fire & (ii) Scouting of Rescue Capability promising Development solutions Process (iii) Definition of a Fire & Rescue Strategic Research and Standardisation Agenda | 2 Conceptual Pillars | 3 5 Thematic Working Groups + involvement of Associated Experts A. Search and Rescue B. Structural fires C. Vegetation fires D. Natural disasters E. CBRNE (SAR) and emergency CNVVF GFMC THW CAFO Medical Response ENSOSP, CAFO, SGSP, CFS, PCF, MSB, KEMEA MSB, CNVVF, CFS, KEMEA ENSOSP, SGSP, CFS, MSB KEMEA, CNVVF SAFE, ENSOSP, CNVVF, FIRE-IN CAFO Associated Experts (AE) community (international community including key thematic practitioner experts from public, private, NGOs bodies, and representative of thematic working groups from existing networks) 1000 experts expected | 4 Thematic Group C – Vegetation / Landscape Fires Partners - Global Fire Monitoring Center (GFMC) (lead) - Catalonian Fire Service - Pau Costa Foundation - Int. Ass. Fire & Rescue Services (CTIF) - KEMEA - European Associated Experts and thematic networks and other stakeholders (community of practitioners) | Thematic Group C – Vegetation / Landscape Fires Emphasis - Science-Policy-Interface - Underlying causes of landscape
    [Show full text]