No. 53 April 2018 STEEL CONSTRUCTION TODAY & TOMORROW http://www.jisf.or.jp/en/activity/sctt/index.html

Special Issue Japanese Society of Steel Construction

JSSC Commendations for Outstanding Achievements in 2017

• JSSC Awards 1 in

• Outstanding Achievement Awards 3 Shinjuku Toho Building 4 [Tokyo Garden Terrace Kioicho] Kioi Tower

• Thesis Awards TM&ⒸTOHO CO., LTD. 5 Relationship of Macro Stress and Maximum Principal Stress on Electro-slag Weld Zone 6 Fatigue Crack Growth Rate of Steel under Large Cyclic Strain and Its Application

Feature Articles: Japanese Steel Construction Technologies

7 Passenger Terminal of New Doha International Airport 10 Taipei Nanshan Plaza Project in Taiwan 13 Tsubasa Bridge in Cambodia

Special Article: Stainless Steel

16 Lean Duplex Stainless Steel for Selective Water Intake Facility

18 JSSC International Events Back cover Message from JSSC International Committee Chairman

Published Jointly by

The Japan Iron and Steel Federation

Japanese Society of Steel Construction JSSC Commendations for Outstanding Achievement in 2017—JSSC Awards Osman Gazi Bridge in Turkey Prize-winner: IHI Infrastructure Systems Co., Ltd.

Fig. 1 General Arrangement of Osman Gazi Bridge Project Overview [Unit: mm] The Osman Gazi Bridge named in hon- 120 000 2 682 000 105 000 or of (1259-1326, who founded 92 050 566 000 1 550 000 566 000 67 250 the Ottoman Empire in 1299), locates in North side span Main span South side span North side North tower Main span South tower South side northwest Turkey and carries the Ge- span pier span pier +EL.63.050 +EL.63.050 bze-Orhangazi--Izmir motorway (stiffening girder) +EL.252.000 +EL.80.330 (cable) +EL.252.000 (stiffening girder) +EL.57.500 (cable) +EL.77.080 +EL.57.500 (cable) across the Sea of Marmara at the Bay of (stiffening girder) +EL.24.000 +EL.33.023 Izmit between the Diliskelesi Peninsula

on the north and the Hersek Peninsula on South tower North anchorage North tower Navigation clearance (height) 64 300 foundation South anchorage the south. foundation Istanbul Navigation clearance (width) 1 000 000 +MSL.+0.401 Bursa The bridge, contracted to IHI Infra- Legends EL. : Elevation (unit: m) structure Systems Co., Ltd. (IIS) on an MSL. : Mean sea level (unit: m) EJ. : Expansion joint EPC (Engineering, Procurement and Construction) basis, was constructed with a 1,550 m main span making it the fourth longest suspension bridge in the world. The scale of the bridge and the tight construction schedule in the EPC contract required the state-of-the-art and sustainable design, well-proven con- struction methods adapted to the techni- cal challenges and financial success for the project. (Refer to Fig. 1) Construction was started in January 2013 and the bridge opened to traffic on July 1st, 2016 only within 3.5 years. More than 83,000 tons of steel has been used and 200,000 m3 of concrete has been cast in total. (See Photos 1 and 2)

Engineering Challenges Photo 1 Aerial view of Osman Gazi Bridge Since the bridge locates in a high seis- mic zone where magnitude 7.4 Kocaeli Earthquake took place in 1999 along the North Anatolian Fault (NAF), high dura- bility against huge seismic events is re- quired with achieving very fast and safe construction. To realize this requirement, IHI has managed and collaborated with a number of subcontractors in more than 10 countries and overcome many engi- neering challenges. The tower foundations are concrete caissons placed 40 m below sea level on a gravel bed over soil strengthened by 195 nos. of the steel inclusion piles per tower (Fig. 2). The tower foundation is allowed to move by releasing friction, functioning as an isolation system during a huge earthquake (return period of 2,500 Photo 2 South anchorage area and the bridge years). The NAF is running close to the bridge site, around 2 km away from the The two towers are 252 m high, each son fabrication work and the tower fabri- south anchorage area, and the south an- consisting of two single-celled box legs cation work, although the concrete tow- chorage is in the secondary fault zone. It with two cross beams. The steel towers ers are common for the long-span bridges is the first case in the world in which this have been chosen to minimize the whole in the world except for in Japan where isolation system is applied to the suspen- construction period by overlapping the technology of the steel towers has been sion bridges. foundation work at the seabed, the cais- developed. Each tower leg is divided in-

1 Steel Construction Today & Tomorrow April 2018 Fig. 2 Schematic Image of Tower Foundation

Photo 4 Main cable erection by PPWS method

the fabrication shops or on site to super- vise the fabrication work and superstruc- ture construction works. The purpose of this supervision is not only to construct the bridge with high quality based on Japan’s experiences but also to transfer their knowledge to Turkey and to con- tribute to Turkey’s technology develop- Photo 5 Deck erection by lifting device ment. Furthermore, the project welcomed vices for erection (Photo 5). To achieve many internship students from Turkey Photo 3 Tower block erection by floating crane further shortening of the construction and abroad and site visits by local chil- period, the typical 2 blocks in the main dren who will play important roles in the to 22 blocks, erected by floating crane span were connected into a 50 m long future. (Photo 6) for the lower half and by jib-climbing block by welding at the fabrication shop. crane for the upper half and connected This reduces the number of on-site weld- Acknowledgement each other by combined method of weld- ing joints (thus welding work) and the The authors are deeply grateful to KGM ing and HSFG bolt connection (Photo 3). period between the deck closure to the (General Directorate of Highway, MOT The main cables are made of a pre- traffic opening into only 2 months. Turkey) and YATIRIM VE IS- fabricated parallel wire strand (PPWS), LETME A.S for guiding us to a success- each consisting of 127 high strength steel Contribution to Social Develop- ful completion and their permission on wires of 5.91 mm in diameter and having ment publication of this paper. ■ a breaking strength of 1,760 MPa. 110 In the project, more than 100 Japanese PPWS per one main cable are spanned engineers were stationed in Turkey at between the cable anchorages and 2 ex- tra PPWS are placed between the tower and the cable anchorage on both sides. It is the biggest diameter of the wires used in the PPWS method in the past suspen- sion bridges and it makes the anchorag- es at both ends smaller for less concrete volume and shorter construction period. (See Photo 4) The deck is a hexagonal closed steel box girder with a width of 30.1 m and a depth of 4.75 m and is carrying three lanes of highway traffic in each direc- tion. The walkway for maintenance vehi- cles with a width of 2.9 m is at both sides of the steel deck similar to the 1st and the 2nd Bosporus Bridges. The deck is divided into 117 segments of 25 m length typically due to the capacity of lifting de- Photo 6 View at tower top

April 2018 Steel Construction Today & Tomorrow 2 —Outstanding Achievement Awards Shinjuku Toho Building Prize-winner: Takenaka Corporation

The Shinjuku Toho Building is a com- two conflicting requirements, extra high- Development of an Improved Non- plex building that accommodates a mov- strength concrete-filled steel tube (CFT) scallop On-site Welding Method ie theater, shops and a hotel. Featuring columns were adopted that employ 780 In the construction of high-rise steel- a slender façade, it has 30 stories above N/mm2-grade high-strength steel and Fc frame buildings, it is essential to secure ground and a height of 130.25 m. The 100 N/mm2-grade concrete. This facili- the soundness of column-beam joints. building was completed in 2015 in Shi- tated the successful control of horizontal Concerning the design of the Shinju- juku-ku, Tokyo. (Photo 1) stiffness between the low-rise and high- ku Toho Building, we developed an rise sections during earthquakes (Fig. 1). “improved non-scallop on-site weld- Response Control Using Extra As the inner diaphragm plate had nev- ing method” as the new beam end detail High-strength CFT and New er been used for electro-slag welding of (Fig. 2). With this method, the plastic de- Diaphragm Plate Specifications columns employing 780 N/mm2-grade formation capacity of the column-beam The ratio of height to width of the high- high-strength steel, there was some con- joints can be improved by filling up on- rise section of the building is quite large, cern regarding the securement of weld- site weld scallops by means of welding 6.8 at maximum, and further the horizon- ing quality. Then, full-scale welding and without the expansion of beam ends. tal stiffness of the low-rise section differs tests were carried out on the electro-slag After tests using full-scale T-shaped greatly from that of the high-rise section. welds to establish a steel column manu- specimens were conducted on the new- Because of this, the horizontal deforma- facturing method that would secure the ly-developed welding method in order to tion of the high-rise section becomes required Charpy value, 27J or higher confirm the high deformation capacity of large during earthquakes (Fig. 1). (Photo 2). Consequently, specifications the column-beam joints, the method was To solve this problem, it was neces- for electro-slag welding of the inner di- put into application. The newly-devel- sary to control the horizontal stiffness of aphragm plate were, for the first time ev- oped method offers high applicability for the low-rise section so that it does not er, put into practice for 780 N/mm2-grade common uses and is expected to be used much exceed that of the high-rise sec- high-strength steel columns. in many new building construction proj- tion, although the columns of the low- ects in the future. ■ rise section were required to have suf- ficient strength. In order to satisfy these Fig. 1 Response Control by the Use of CFT Columns Employing 780 N/mm2-grade High-strength Steel

Image of deformation Image of deformation after control of stiffness before control of stiffness

Securement of sufficient strength obtained by the use Photo 2 Macroscopic test results of extra high-strength for electro-slag weld CFT column Fig. 2 Details of Improved Non-scallop On-site Welding Method Column skin plate

On-site welding Diaphragm plate

Photo 1 Symbolic façade of TM&ⒸTOHO CO., LTD. Beam flange south-side surface

3 Steel Construction Today & Tomorrow April 2018 [Tokyo Garden Terrace Kioicho] Kioi Tower Prize-winners: Yuichi Koitabashi, Seiya Kimura, Nikken Sekkei Ltd.; and Kajima Corporation

In the plans for the [Tokyo Garden Terrace In this way, a high durability long life of about 50% compared with a normal Kioicho] Kioi Tower, the following origi- ultra high-rise building was realized in ultra high-rise building, and the story nal ideas (A and B), devices and advanced economizing on steel resources and min- shear forces were reduced to about 75% measures were incorporated to handle the imizing damage to building materials (Figs. 1~3). various tasks involved in the design and from a long-term perspective. Therefore 2) Comprehensive monitoring was carried construction. These ideas led to an archi- a new “high efficiency hybrid vibration out such as measurement of floor re- tecture that contributes to the development control system” that combines the fol- sponse accelerations, displacements with and diffusion of steel structures.(Photo 1) lowing 1) and 2), and other innovative the aim of achieving a long life steel measures were incorporated. structure building, to enable effective Ultra High-rise Building with High 1) An innovative vibration control system maintenance of the vibration control de- Seismic Performance was devised utilizing the properties of vices, which are indicative of the degree the building scheme that was capable of damage in an earthquake. A: Ensure high seismic performance of attaining high energy absorption effi- in which the main structure will re- ciency and capable of reducing the seis- High Efficiency Hybrid Vibration main elastic and the floor response ac- mic force (story shear force) on each Control System celeration will be 250 gal or less dur- story, using the deformation properties ing a major earthquake, including an of a large structure consisting of the B: Scheme to reduce vibrations after inland earthquake in the Tokyo area, to transfer truss structure and coupled steel a long period earthquake or a major enable the functions of the offices and plate walls. The energy absorption ef- earthquake hotel to be maintained continuously. ficiency was increased by a maximum For this purpose an active mass damp- er (AMD) was installed on the roof. The Fig. 1 Overview of Vibration Control Fig. 2 Vibration Control Device Layout AMD has an additional mechanism ca- System Diagram Large axial deformation pable of reducing the amplitude of the vibrations after an earthquake by about 30 to 50% and shortening the time pe- Hysteretic buckling Velocity dependent riod of oscillation by about 3 minutes restrained vibration viscous vibration compared with no vibration control, control brace control brace with the aim of enabling rapid evacua- tion activities. Effective deformation of the brace vibration control devices amplified

Before After deformation deformation Large axial deformation

Fig. 3 Time History of Axial Forces Generated in the Vibration Control System (1 Unit) Absolute sum of maximum force Maximum positive and negative Axial force (kN) generated individually in hysteretic values of axial force generated in velocity dependent dampers the time history with this system 3000 2000 1000 0 −1000 −2000 −3000 Time (sec) Photo 1 Full view of [Tokyo Garden Terrace Kioi- Reduction to about 75% of the absolute sum of each of the cho] Kioi Tower maximum generated forces, by the phase difference between the hysteretic dampers and the velocity dependent dampers

April 2018 Steel Construction Today & Tomorrow 4 —Thesis Awards Relationship of Macro Stress and Maximum Principal Stress on Electro- slag Weld Zone between Interior Diaphragm and Box Column Prize-winner: Takumi Ishii, JFE Techno-Research Corporation

ing. In the electro-slag weld (herein- Takumi Ishii Studies on ESW Fracture Tough- 1991: Graduated from Gradu- after referred to as ESW) of the inte- ness ate School of Engineer- rior diaphragm and column skin plate Two studies on ESW fracture tough- ing, Chiba University; of a column, it is worried that crack- ness were reported by us in past issues Entered Kawasaki Steel ing will break out from the slit tip oc- of Steel Construction Engineering of the Corporation curring between the backing metal and Japanese Society of Steel Construction: 2003: Civil Engineering Dept., JFE R&D Corpo- ration the column skin plate after welding “Study on Fracture Behaviors of Elec- 2009: Steel Research Laboratory, JFE Steel (Fig. 1). tro-slag Welds of Column-Beam Partial Corporation While there are no reports of actu- Models” (Vol. 16 (2009), No. 64) and 2017: Structures Performance Center, JFE al damage caused by such cracking, it is “Study on Fracture Behaviors of Elec- Techno-Research Corporation clear from recent experiments that there tro-slag Welds of Column-Beam Partial is the possibility of brittle fractures oc- Framing Models” (Vol. 17 (2010), No. Higher Toughness for ESW curring in the interior diaphragm ESW 68). In these studies, we noted the frac- The built-up box section column is under specified conditions. Triggered by ture toughness of the weld metal, fusion manufactured by weld assembling four such experimental results, higher tough- zone and heat-affected zone of ESW. steel plates using electro-slag weld- ness is required of ESW. These two studies suggest that there is a positive mutual relationship between the toughness (that denotes the Charpy Fig. 1 Outline of Column-Beam Connection of Box Column and impact energy here) of the weld metal, Anxiety over Brittle Fracture Occurrence fusion zone and heat-affected zone and Interior Backing Position of anxiety over the interior diaphragm stress. In addi- Built-up box section column diaphragm metal brittle fracture occurrence tion, analytical examinations were made of the results of the experiments men- tioned above, which find that the maxi- H-section beam mum principal stress is effective as the fracture toughness parameter that relates ESW to the Charpy impact energy (Fig. 2). Column

SAW Macrostructure of column-beam Estimation of Toughness Re- weld joint section quired for ESW Given this situation, the current study Fig. 2 Relationship between Equivalent Fig. 3 Relationship between proposes a method that connects the crit- Value of Maximum Principal Dimensionless Maximum ical maximum principal stress with the Stress at Fracture Initiation Principal Stress and interior diaphragm stress, which is con- Point and ESW Toughness Level Dimensionless Diaphragm sidered important in the process of cal- Stress that Takes Penetration culating the toughness value required for into Account (Conversion Curve) ESW (Fig. 3). Concurrently, a method is ) 2

u proposed that simply calculates the stress σ c / working on the interior diaphragm of the

m,HA Z column-beam connection. Partial model experiment By making the most of these pro- Partial framing model experiment posals, the maximum principal stress is found from the stress working on the in-

Equivalent value of maximum principal stress at fracture initiation point (N/mm Toughness level of ESW (J) terior diaphragm of ESW without the use

Dimensionless maximum principal stress σ of the finite element analysis, and as a result it is now possible to estimate the

Dimensionless diaphragm stress dσaf /cσu required toughness in terms of the stress level of ESW. ■

5 Steel Construction Today & Tomorrow April 2018 Fatigue Crack Growth Rate of Steel under Large Cyclic Strain and Its Application to Crack Growth Prediction in Welded Joints Prize-winners: Takeshi Hanji, Associate Professor, Nagoya University; Nao Terao, Graduate student, Nagoya University; Kazuo Tateishi, Professor, Nagoya University; and Masaru Shimizu, Assistant Professor, Nagoya University

propagated straight along the side groove, of the material. Based on the results, the Takeshi Hanji and that the location of the crack front was crack growth rate formula can be derived. 2001: Graduated from School almost same throughout the thickness di- of Engineering, Nagoya University rection because of the side groove. Fatigue Crack Growth Prediction 2006-2009: Researcher, University in Welded Joints of California, San Fatigue Crack Growth Rate Formula Low cycle fatigue tests were conduct- Diego; EcoTopia Science Institute, Elasto-plastic finite element analysis ed using corner welded joints. The crack Nagoya University; Center for Urban was used to calculate the cyclic J-inte- growth from the weld root in the joint Earthquake Engineering, Tokyo Institute of Technology gral range at the cracks in the specimens. was predicted to confirm the applicabil- 2010-: Associate Professor, Graduate School of The cyclic J-integral range ΔJ was de- ity of the proposed crack growth curve. Engineering, Nagoya University fined as the range of fluctuation of the J- The crack growth in the test was es- integral from the minimum to the maxi- timated based on the cyclic J-integral mum load points of the loading process. range from the analysis and the proposed Low cycle fatigue is one of the failure The cyclic J-integral range is calculated formula by the following steps: modes in steel structures during earth- as in the following: (a) The initial crack length was defined quakes. With a focus on crack growth in and its cyclic J-integral was calculat- the low cycle fatigue region, this study ed based on the analysis. developed a fatigue crack growth curve, (b) According to the proposed formula, and verified its applicability to crack crack growth length da due to one growth prediction in welded joints. where W’ is the range of strain energy loading cycle (dN = 1) was calculat- density, ΔT is the range of traction vec- ed. Fatigue Crack Growth Tests tor, Δu, Δσ and Δε are the ranges of dis- (c) The crack length a was updated to Fatigue crack growth tests under high- placement vector, stress and strain in the a+da, and again, its cyclic J-integral ly plastic conditions were performed us- loading process, respectively. was calculated. ing compact tension specimens with side Fig. 2 shows the relationship between (d) The crack growth length da was re- grooves. Three kinds of materials (struc- the crack growth rate da/dN measured calculated using the formula. tural steels of 400 N/mm2 and 490 N/mm2 during the test and the cyclic J-integral The above steps were repeated. classes, and deposit metal) were used. range ΔJ calculated analytically. All plots Fig. 3 shows the prediction results. The Each specimen was loaded under displace- were distributed in the same area, mean- predicted and observed crack growths ment control. The range of fluctuation of ing that the cyclic J-integral range corre- were in good agreement. This demon- the displacement was controlled during lates with the crack growth rate regardless strates that the crack growth of the cor- the test. The crack length was measured at ner welded joints can be predicted using regular intervals using a microscope. Fig. Fig. 2 Crack Growth Rate the cyclic J-integral range and the pro- 1 (a) shows an example of a crack tip ob- vs Cyclic J-integral posed crack growth formula in the low served from the side surface of the speci- Range cycle fatigue region. ■ men. A photograph of one of the fracture surfaces after the test is shown in Fig. 1 Fig. 3 Crack Growth Prediction (b). These figures reveal that the crack in Welded Joints

Fig. 1 Test Results Test result Crack propagation direction Fatigue crack Prediction Side SM400A grooves SM490A Test result Weld metal Prediction Crack tip da –6 1.67 Fracture surface due to 5mm =9.6×10 (ΔJ ) Crack length (mm) 1mm low cycle fatigue loading dN Crack growth rate da/dN (mm/cycle) (a) Crack tip observed (b) Fracture surface from side surface Cyclic J–integral ΔJ (N/mm) Number of cycles

April 2018 Steel Construction Today & Tomorrow 6 Feature Articles: In the following, examples are introduced in which Japanese steel con- struction technologies are applied in various countries, or examples of Japanese Steel steel construction projects are introduced in which Japanese companies Construction Technologies have contributed toward the successful completion of these projects.

Feature Articles: Japanese Steel Construction Technologies (1) Passenger Terminal of New Doha International Airport by Tsutomu Hirata, Taisei Corporation

Outline of New Doha Internation- al Airport Outline of Passenger Terminal Building In Qatar, plans called for the construction Location: Doha, Qatar of a new airport at a 29 km2-spacious site Total floor area: About 484,000 m2 (60% accounted for by reclaimed land) lo- No. of stories: 5 stories aboveground cated south-east of Doha, the capital of Qa- Type of structure: Steel structure (including concrete-filled box section columns) tar. It is a leading airport in the Middle East Application: Airport facilities—passenger terminal and concourse that consists of a passenger terminal with Project owner: New Doha International Airport Steering Committee an initial annual handling capacity of 24 Construction management (CM): Overseas Bechtel Inc. (O.B.I.) million passengers, a cargo terminal with Design consulting: Hellmuth, Obata+Kassabaum (H.O.K.), Middlebrook+Louie an annual handling capacity of 1.4 mil- (M+L, currently Louie International) lion tons of cargo, two runways each with Construction: Sky Oryx Joint Venture (Taisei Corp. of Japan 65%, TAV of a length exceeding 4,000 m, hangars, ca- Turkey 35%) tering facilities, a control tower and a VIP terminal for the exclusive use of the roy- al family. The New Doha International Air- Committee and the Sky Oryx Joint Ven- passenger boarding bridges. The main port is a grand-scale national project com- ture in June 2006. terminal building is a complex five-story posed of more than 100 contract packages. steel structure with a wave-formed arch- The New Doha International Airport • Outline of Terminal Building shaped roof that is supported by part con- Terminal, among others, is the nucleus of The first-phase of the work covered the crete-filled steel box section arch col- the project (Photo 1). Its construction peri- construction of the main terminal build- umns. The second-phase of the work od ran about 64 months from March 2006 ing composed of a main airport passen- consisted of an extended airport passen- to July 2011. The airport was opened to ger terminal, a passenger concourse, el- ger concourse and girder framing for an the public in 2014, establishing it as a hub evated viaducts, pedestrian bridges and indoor monorail that serves as a means airport in the Middle East. The passen- ger terminal building was constructed by a joint consortium led by Taisei Corpora- tion, a major general contractor in Japan, and a partner company from Turkey.

Outline of Construction of New Passenger Terminal • Tendering Details of the Project Taisei Corporation participated in the tender for the new airport terminal build- ing construction by forming a joint ven- ture (Sky Oryx Joint Venture) with TAV of Turkey, who are both experienced in airport construction and manage- ment. Pre-qualification started in April 2005, and in March 2006 the joint ven- ture received a purchase order/construc- tion start order, which led to the conclu- sion of a formal agreement between the New Doha International Airport Steering Photo 1 Full view of Passenger Terminal of New Doha International Airport in Qatar

7 Steel Construction Today & Tomorrow April 2018 of transportation from the main terminal arch columns, hybrid steel-composite framing. building to the more distant departure structures, were adopted in constructing During the construction of the huge gates. These facilities comprise a two- the passenger terminal and concourse sec- terminal building, notable changes were story steel-structure with a high vaulted tion, where a large-span arch-shaped ter- made to the terminal design prior to and roof. minal building roof structure was built us- after the start of the project. To cope with The total floor area for the first to sec- ing part concrete-filled steel box section this situation, it was required that the joint ond-phase works is about 490,000 m2 arch columns having span lengths of 160 venture presented alternative proposals and the amount of steel used came to m and 80 m. (Refer to Photo 2 and Fig. 1). and construction plans applicable to the about 54,000 tons. While the construc- The upper arch-shaped hollow steel project. As a prime example, a propos- tion work for the main terminal build- framing of the main building was in- al was submitted by the contractor prior ing had to overcome strict restrictions stalled on top of the lower concrete-filled to the start of the project that the original imposed by the harsh desert climate, lo- box section arch columns. The length of RC structure for the arch column lower gistic constraints and local practices, the steel-frame members for the main build- sections be changed to a concrete-filled main terminal building saw a full-scale ing measures from 40 m to 60 m in max- steel box column structure. In addition, it opening on May 27, 2014. imum. Three airport passenger concours- was required after the start of the project es extend to the east, west and north sides that an additional concourse be construct- • Steel Frame Construction of the terminal building. ed. As it was necessary for the building The main passenger terminal and its con- All the arch-shaped steel framing was contractor to be able to meet these design necting concourse section have an approx- assembled on the ground, and the tem- changes, the Sky Oryx Joint Venture suc- imately 1 km×1km square footprint with a porary support bent construction method cessfully cleared all these requirements to total floor area of about 490,000 m2. The was adopted for the erection of the steel complete the terminal building.

Photo 2 Installation of arch column steel framing

Fig. 1 Installation Plan for Arch Column Steel Framing Procedure for installing steel framing Step 1: Installation and welding of arch column steel framing Step 2: Installation, bolting and welding of arch steel framing Step 3: Column base mortar placement Step 2: Installation, bolting and Step 4: Installation, bolting and welding of steel framing for main building welding of arch steel framing Step 5: Concrete filling of square steel box section columns Step 6: Jacking down and dismantling of bent Step 4: Installation, bolting and welding Indicating welded sections of steel framing for main building

Step 6: Jacking down and dismantling of bent

Step 5: Concrete filling of square Step 1: Installation and welding of steel box section columns arch column steel framing

Step 3: Column base mortar placement

April 2018 Steel Construction Today & Tomorrow 8 Collaborative System between Accurate Response to Technolog- Overcoming Difficult Work in the Engineers from Many Countries ical Issues Desert by the Optimum Use of In this airport terminal project, as an out- Diverse kinds of technological issues oc- Technological Strengths standingly large-scale construction proj- curred during the terminal construction. The project of constructing a passenger ect to be undertaken in the Middle Eastern The steel products used for construc- terminal having an originally planned to- country of Qatar, it was considered nec- tion were imported from various nations, tal floor area of 239,000 m2 started with essary to establish a multinational collab- and thus there were many cases in which an initially planned construction period orative system for those working on the quality, the dimensions and other spec- of three years. Finally, a terminal having project in order to build it efficiently. ifications could not be easily and cor- a total floor area of 484,000 m2 was com- About ten engineers and architects in rectly judged simply by examining dif- pleted in a construction period of more charge of the contractor’s design manage- ferent mill sheets. Further, an important than five years (Photos 4 and 5). ment were stationed on site to proceed role was imposed on the construction en- Nearly 20,000 workers from 25 coun- with the project. They came from Turkey, gineer who managed the entire construc- tries participated in the construction of the Philippines, Egypt and Japan. The per- tion project—to judge whether or not the the terminal building. The Sky Oryx sons working in the construction manage- specifications of the structural materials, Joint Venture dealt with complex process ment (Overseas Bechtel, Inc.) and de- prescribed in the structural drawings pre- control by promoting communications sign (Hellmuth, Obata+Kassabaum and pared by the structural design office, were among workers from different countries Middlebrook+Louie) teams were most- appropriate. On top of these, because di- by respecting their various cultures, reli- ly Americans, and the company work- verse collaborative design offices were gions and habits. As regards the influx of ing on the steel-frame manufacture (EVS used in the operations depending on the construction materials supplied by var- Metal Inc.) was an Indian company. The engineering capabilities and the special- ious countries, the joint venture closely sense of values of these engineers and ar- ized field, it was necessary to prudently monitored the unsettled delivery terms. chitects and the languages they each used undertake the choice of collaborative en- In addition, the contractor was faced were different. One of the important roles gineering offices at the site. with difficulties in accurately follow- played by the Sky Oryx Joint Venture was In spite of technological issues such as ing the construction schedule of such a to guide the multinational engineers and these, the terminal building was complet- large-scale project and efficiently attain- architects towards one purpose, the suc- ed without major issues, supported by the ing the daily targets. cessful completion of the project. (Refer technological strengths accumulated by Even in the face of such hard condi- to Photo 3) the Sky Oryx Joint Venture. In this regard, tions, the Sky Oryx Joint Venture joined in order to successfully promote construc- forces to proceed with the new airport ter- tion projects overseas, it is considered im- minal project—transferring to the work- portant to implement design verification ers the basic knowledge accumulated by from multilateral viewpoints and to base experienced Japanese engineers, training them on the on-site conditions. the workers in such basic knowledge, ac- curately coordinating the entire project, and implementing the basic practices in- volved in construction management. It is believed that these daily accumulated ef- forts produced the positive results that led Photo 3 On-site confirmation of arch column steel framing by engineers to the successful completion of the termi- nal building of the New Doha Internation- al Airport in compliance with the high ex- pectations of the people of Qatar, and the supervising design and CM teams. ■

Photo 5 The huge-scale terminal project was successfully completed by the joint ef- forts of workers and engineers from Photo 4 Top light of main terminal building many countries.

9 Steel Construction Today & Tomorrow April 2018 Feature Articles: Japanese Steel Construction Technologies (2) Taipei Nanshan Plaza Project in Taiwan by Hiroshi Kawamura, Mitsubishi Jisho Sekkei Inc.

Outline of the Project and exhibitions are to be held. Bus ter- As a result of these processes, Mi- The Taipei Nanshan Plaza is a large-scale minals are located in the underground tsubishi Jisho Sekkei was able to suc- project composed of complex facilities floor of the cultural building. These three cessfully establish a highly reliable re- that are located in the central area of Tai- buildings with a total floor area of about lationship with the client and the local pei, Taiwan. The project is located at a 200,000 m2 are designed and constructed engineers, which led to a structural de- vacant lot formerly used as an exhibition as one unified building complex. sign that imparts a unique configuration site and adjoins the Taipei 101, a 101-sto- Construction started at the end of and a striking design concept to each ry high-rise building with a height of 509 2013. Currently, the project is underway building. m, the tallest in Taiwan. After comple- with completion scheduled for the end of tion of the current project, the pair con- March 2018. The Taipei Nanshan Plaza Fig. 1 Image of a Pair of Landmark sisting of Taipei Nanshan Plaza and Tai- is becoming the focus of public attention Towers in Taipei: Taipei Nan- pei 101 will constitute a new landmark in in Taipei. Table 1 shows an outline of the shan Plaza (left) and Taipei 101 Taipei (Fig. 1). three buildings. Mitsubishi Jisho Sekkei Inc. joint- ly with its client, Nan Shan Life Insur- Design Approach ance Company Ltd., participated in the While Nan Shan Life Insurance was pro- project competition held by the Taiwan Japanese and possessed a positive out- City Government in 2012, in which our look in incorporating advanced technol- proposal was adopted after winning first ogies from Japan into the design of the place in the competition. Nan Shan Life project, Mitsubishi Jisho Sekkei did not Insurance Company, a major Taiwanese particularly impose Japanese styles on its life insurance company, is the owner and client, but rather respected local customs, developer of the project. The company laws, regulations and procurement pro- leases the land from the Taiwan Govern- cedures. In light of this, Mitsubishi Jisho ment and also develops and operates the Sekkei conducted advance exchanges of Taipei Nanshan Plaza. opinion with local engineers and authori- The Taipei Nanshan Plaza project is ties when examining the various propos- composed of three buildings: an office als for the Taipei Nanshan Plaza project, tower with a height of 272 m with restau- and when explaining these proposals to rants in the three topmost floors, a retail the client, we stressed that the proposals building housing top-brand shops, and a were prepared after consulting with local cultural building where various events engineers and authorities.

Table 1 Outline of Three Buildings in Taipei Nanshan Plaza Office tower Retail building Cultural building Location Sung Jen Road, Xinyi District, Taipei, Republic of China (Taiwan) Cultural facility and entrance Main applications Office and carpark Shop and carpark to office tower Site area 17,708.00 m2 Building area 10,271.41 m2 Total floor area 192,891.35 m2 5 stories underground, 48 No. of stories stories aboveground, 2-story 5 stories underground, 5 stories underground, penthouse 9 stories aboveground 3 stories aboveground Maximum height 272.00 m 56.75 m 24.61 m Aboveground: Steel structure Aboveground: Steel structure Aboveground: Steel structure Type of structure (~36 floors: CFT column) (CFT column) (partially CFT column) Underground: SRC structure Underground: SRC structure Underground: SRC structure Grade of steelwork SN490B, SN490C, SM570C; Maximum plate thickness: 70 mm; Maximum column size: 2000 mm×1400 mm Project owner Nan Shan Life Insurance Company Ltd. Scheme design/Supervision of design development and Mitsubishi Jisho Sekkei Inc. detail design Design development and Architect: Archasia Design Group; Structural engineer: Evergreen Consulting Engineering, Inc. detail design Contractor Fu Tsu Construction Co., Ltd.; Steelwork fabricator: Chun Yuan Steel Industry Co., Ltd.

April 2018 Steel Construction Today & Tomorrow 10 Structural Design Concept columns are bent (Fig. 3). Intermediate • Retail Building • Office Tower machine rooms are located on these truss The retail building is a nine-story above- The office tower has 48 stories above- floors with belt trusses used for the out- ground structure with a height of about ground and a height of 272 m, and the ra- er periphery and outrigger trusses for the 57 m. It presents an image in which jew- tio of height to breadth is about 5.8 (Pho- interior sections. el boxes are piled in shifted forms at to 1). The frame is a double-tube structure In the office tower building, the wind each floor (Photo 3). The approximate composed of a core in which braces (5- load is more predominant than the seis- size of the floor plate is 66 m×50 m, and 48 floors) and steel plate seismic-resis- mic load, and in order to suppress the a moment frame steel structure was ap- tant walls (1-4 floors) are arranged in the vibration caused by the wind load, two plied that adopts a basic module measur- short-side direction and an outer periph- tuned mass dampers (TMDs) weighing ing more or less 11 m×8 m in conformity eral frame. With regard to the overall ap- 250 tons each were installed on the up- with a floor-to-floor height of 6~7.2 m. pearance of the office tower building, per truss floor. the building’s frame is designed to pro- At the topmost section of the office mote the idea of two joined palms (Fig. tower building, sky restaurants having a 2), and with regard to the outer appear- floor-to-floor height of more than 7.2 m ance of the low-rise section, the frame is were planned for each of the three top- designed to offer a unique configuration most floors. Because the building exte- in which the outer wall surface becomes rior is designed based on the underlying narrower toward the bottom (Fig. 3). concept of a vertical composition, it was Meanwhile, in order to secure both required for the exterior of the topmost horizontal and torsional rigidity for the section to possess high transparency that building structure, truss floors were pro- would allow for a fine view. Accord- vided on the top and intermediate parts ingly, we proposed a framing structure and the lower part where the perimeter in which diagonal kickers and horizon- tal trusses would be installed, thereby al- lowing the client’s wishes to be success- Photo 2 Erection of topmost section of office fully put into effect. (Refer to Photo 2 tower* and Fig. 4). Fig. 4 Framing of Topmost Section of Fig. 3 Framing Model of Office Tower Office Tower

Truss Diagonal kicker

Horizontal truss

Photo 1 Erection of office tower*

Fig. 2 Image of Joining Together of Palms to Express Thankfulness

Photo 3 Erection of retail building

11 Steel Construction Today & Tomorrow April 2018 The overhanging lengths that occur due um panels. (Refer to Photo 5 and Fig. 6) al foundation of the outer shell, on which to the shifting of floor units at each floor Users and visitors come up to the sec- parallel arch members sit in 3-m spacing is about 10 m in maximum, and diverse ond floor by an escalator that is installed in the short-side direction (Fig. 7). methods were effectively applied to install in the first-floor atrium hall. The second In the underground space beneath the the suspended frame using triangle-shaped floor connects to the office tower and al- cultural building are located a large-size trusses, Vierendeel trusses or cantilevered so serves as an access way to the event bus parking lot and traffic lanes, and as a beams depending on the respective over- hall on the third floor. result, arrangement of supporting points hanging lengths. (Refer to Fig. 5) The event hall on the third floor is a for the superstructure were limited. Due For the 1~3 floors of the retail building 30 m×28 m column-free space arranged to these needs, the complex structure dis- that connects with the office tower build- on top of the first-floor atrium hall. It was cussed above was adopted for the framing ing, a structural form was devised in which examined whether or not the outer con- of the cultural building. Discussions on the these three floors are put onto the corbel figuration with its unique architectural practical application of this complex struc- provided in the office tower and bearings design could be fused with the building ture were made between the local structur- having a sliding mechanism were installed structure, and then we proposed a fram- al engineers and Mitsubishi Jisho Sekkei on the corbel. The plan for the exterior of ing type in which the seismic load is dealt to reconcile proposals and plans. the retail building called for a structural sys- with by using an outer shell in the long- tem in which the entire building was cov- side direction and the installation of inner Acknowledgments ered by a screen of Taiwan’s national flow- columns is reduced to a minimum. The I would like to express my sincere grat- er plum-blossom patterns (Photo 4), that upper chord of the triangle-shaped trusses itude to our client, Nan Shan Life Insur- was manufactured by three-dimensional- on the third floor functions as a structur- ance Company Ltd., who gave us ex- ly bending a stainless steel-formed materi- tensive guidance regarding the current al. As regards the framing that supports the project, and also to Evergreen Consult- complex exterior members, a stress analy- ing Engineering, Inc., who gave us kind sis was made to examine its applicability. support. ■

• Cultural Building *Photos by courtesy of: The cultural building has three stories Photo 1 by Fu Tsu Construction, Photos aboveground and a height of about 25 2 and 6 by YKK-AP, Photo 4 by Kinzi m. It is composed of unique polyhedrons having an octagonal plane shape. The Note building is used as both an entrance to the The current article was prepared based office tower and an event hall. The roof Photo 5 Erection of cultural building on the progress of the project as of No- and exterior walls are composed of titani- vember 2017. Fig. 6 Image of Cultural Building Serving also as Office Tower Fig. 7 Framing Model of Cultural Building Fig. 5 Framing Model of Retail Building Entrance Parallel arch member aligned Triangle-shaped truss in 3-m spacing

Triangle-shaped truss

Vierendeel truss

Photo 4 Screen having plum-blossom patterns* Photo 6 Distant view of Taipei Nanshan Plaza from Elephant Mountain in Taipei*

April 2018 Steel Construction Today & Tomorrow 12 Feature Articles: Japanese Steel Construction Technologies (3) Tsubasa Bridge in Cambodia by Masahiro Nomoto, Chodai Co., Ltd.

Project Outline the PC cable-stayed bridge, the main ducted in order to determine a main girder National Road No.1 (NR1) in Cambo- bridge of the project. cross-sectional shape with high wind re- dia is a part of the Asian Highway and sistance and stability. Southern Economic Corridor which con- Design Phase nects Ho Chi Minh City and Bangkok via • Edge Girder Bridge • Wind Tunnel Tests Phnom Penh. As the economy of the sur- An edge girder was selected as the main To select a cross-section for the main rounding areas developed, traffic jams due girder type for the PC cable-stayed bridge girder with high wind resistance and sta- to increased traffic demand became a huge in consideration of the scale of the bridge problem. Especially the Mekong River (13.5 m effective road width). Fig. 3 Edge Girder Dimensions Total width 16980 crossing area was a traffic bottleneck be- Edge girders are more cost-effective Cable space 14500 cause of the low capacity of the ferries than box girders since they are easier to used to cross the river. Tsubasa Bridge was reduce the dead load resulting from the thus constructed as a Japanese grant aid concrete volume (Fig. 3 and Photo 2). project to alleviate this bottleneck. (Refer They are also superior in assuring qual- to Figs. 1 and 2, Photo 1, Table 1) ity in countries with less developed tech- This article describes the design char- nology, because they enable easier form- acteristics and construction method of work and bar arrangement work through a simpler girder design and shape. Edge girders can be affected by torsion flut- ter at low wind speeds due to the shape of the main girder because of their low torsion rigid- ity compared to box girders. Therefore, wind tunnel tests were con- Photo 2 Edge girder

Photo 1 Full view of Tsubasa Bridge Fig. 1 Location Map

Phnom Phen Table 1 Project Outline

Project length 5.500 km Mekong Prey Veng City Bridge type 3-span continuous PC cable-stayed bridge River Prey Veng Foundation type Hypostyle foundation Spans 160 m+330 m+160 m East-West Economic Corridor Kandal Southern Economic Corridor Bridge width 13.500 m Neak Loeung Design velocity 80 km/h Neak Loeung

Fig. 2 General View of the Bridge

Shipping passage Shipping passage Shipping passage

Clip pile Clip pile Clip pile Clip pile

13 Steel Construction Today & Tomorrow April 2018 bility, wind tunnel tests were conducted • Stay Cables adopted for the cross beams which con- not only for the original cross-section but Taking into account the benefit of wind- nect the shafts. also for 3 other cross-sections with dif- resistant stability, a parallel stay cable The shaft cross-section and the shape of ferent fairings using 1/60 scale models arrangement was adopted. Cables which the cross beams and the top of the towers (Table 2 and Photo 3). are vertically arranged in the cross-sec- were examined for their aesthetic qualities. In the experiment, a uniform wind tion help mitigate the sense of confine- The stay cable anchorages are a sep- flow with −3, 0, and +3 degree angles of ment that pedestrians may feel and also arate type which makes maintenance attack was applied to the spring support- ensure easier constructability during stay work easier. U-shaped PC strands and ed partial model with 2 degrees of free- cable installation. PC bars were used to reinforce the an- dom of vertical deflection and torsion. The vertical spacing of the stay cables chorage zones (Fig. 8). Deflection vortex excitation and tor- is between 1.25 m and 2.3 m on the tow- sion flutter occurred on the original ers and 8 m on the concrete deck. Construction Phase cross-section with a −3 degree angle of Non-grouting site assembly cables • Unexploded Ordnance attack (downward wind direction). Al- were selected considering their advan- Although about 4,200 unexploded ord- though the amplitude of deflection vor- tages which include easy transportation nances (UXOs) were removed with the tex excitation was less than allowed, tor- and installation and reliable rust-proof- cooperation of the Cambodian military sion flutter occurred at a wind speed of ing. before the start of construction, an explo- 44.0 m/s which is smaller than the veri- sion still occurred during the construction fying wind speed of 52.9 m/s. Therefore, • Towers of the foundation piles of the cable-stayed the same experiment was conducted with The towers are H-shaped to conform different shapes of fairings and a (small) with the parallel out-plane arrangement Fig. 7 Front View of H-shaped Tower fairing was adopted which did not suf- of the stay cables (Fig. 7). An RC struc- fer from flutter at an 80 m/s wind speed ture was adopted for the shafts which are and showed little deflection vortex exci- always under compression, while a PC tation. (Refer to Figs. 4, 5 and 6) structure with a hollow cross-section was

Table 2 Wind Tunnel Test Conditions Fig. 4 Fairings for Wind Tunnel Testing Structural damping ratio 0.02

Design velocity U10=30 m/s Degree of roughness 0.16 Girder altitude 45.8 m Target wind velocity 38.3 m/s

Original Fairing— cross section Upper 30 degrees

Fairing (large) Fairing (small)

Photo 3 Wind tunnel test Fig. 6 Static Three-component Force Test Results Fig. 5 Wind Speed-Amplitude Relation (Torsion −3 deg.)

April 2018 Steel Construction Today & Tomorrow 14 bridge. Luckily no one was hurt, but a re- the construction period (Photos 4 and 5). Conclusion investigation and the adoption of neces- The opening of Tsubasa Bridge shortened sary countermeasures led to a 4-month • Adoption of 8 m Blocks the time needed to cross the river from 7-8 suspension of construction work. In order 8 m blocks were adopted with an under- hours in busy seasons to only a few min- to recover this delay and shorten the con- slung form traveler for the main girder utes. The fact that the Asian Highway was struction period, the methods described cantilever construction which enabled a connected by road had a big role in im- below were adopted which enabled con- basic construction cycle of 10 days (Pho- proving the economy and quality of life of struction to be completed on time. to 6 and Fig. 9). For this method, counter- surrounding areas. Thorough discussions measures such as prefabricated rebar for were held with the residents around the • Sliding Form and Prefab Con- the cross girders of the main girders were river from the route selection stage and the struction taken (Photo 7). Counter weights were al- project was carefully planned to ensure the For tower construction, a jumping form so applied on the opposite end of the can- full comprehension and acceptance of the system with integrated formwork and tilever in order to prevent an unbalanced various project stakeholders in line with scaffolding and prefabricated rebars was situation which was an adverse reaction Japan’s official ODA policy. ■ adopted in order to save work and shorten from the large-scale form traveler.

Photo 4 Jumping form system Photo 5 Prefab rebar for tower

Fig. 8 Stay Cable Anchorage Zone

U-shape PC Number of PC Reinforcement U-shape tendon (2/row) tendon PC cable for T1

T

P T T P

T Photo 6 Form traveler for 8 m blocks

Reinforcement PC bar for T2

Fig. 9 Structural Drawing of Form Traveler Block length = 8.0m Launching hanger Casting hanger Anchorage for temporary tensioning work Kicker

Bracket for temporary tensioning work Jacking system for traveling Photo 7 Prefab rebars for cross beam

15 Steel Construction Today & Tomorrow April 2018 Special Article: Stainless Steel Lean Duplex Stainless Steel for Selective Water Intake Facility by Yasuhiro Tsuruga and Noriaki Fukushima, IHI Infrastructure Systems Co., Ltd.

Mitigation of Burdens and Costs Table 1 Outline of Selective Water Intake Facility of Futase Dam The Futase Dam is a multipurpose dam Kanto Regional Development Bureau, Ministry of Land, Infrastructure, constructed in 1961 with the aim of con- Order placement Transport and Tourism trolling floods, securing agricultural irri- gation water and operating a local gov- Project name Installation of selective water intake facility at Futase Dam ernment-owned hydropower station. In Selective water intake facility of the multi-stage rubber membrane type×1 Facility 3 order to reduce the discharge of cold and Water intake amount: 7.5 m /s; number of stage: 8; water intake range: 40 m turbid water from the dam into the riv- Installation site Ootaki, Chichibu, Saitama Pref. er below, a selective water intake facil- Construction term January 2014~June 2016 ity was additionally installed at the in- Structural flow section of the water conduit pipe for materials applied SUS304, SUS821L1 power generation. Because of the additional installation stage rubber membrane type was adopt- ducing costs. Fig. 1 shows an entire dam at the existing gravity arch dam, a selec- ed with the aim of mitigating the burden body, and Fig. 2 an overview of the se- tive water intake facility of the multi- placed on the existing dam body and re- lective water intake facility.

Fig. 1 Drawing of Entire Dam Structure (seen from upstream side) Outline of the Selective Water In- Crest gate (Constructed by IHI in 1961) take Facility Table 1 shows an outline of the selective water intake facility at Futase Dam. The selective water intake facility is com- posed mainly of an expansion/contrac- tion gate leaf (impervious membrane, movable frame), a guiderail serving as the lifting guide for the gate leaf, a wire rope-type lifting device, and a flying deck. The gate leaf is supported by the lifting device, and the lifting device is Selective water Conduit gate Discharge pipe for irrigation supported by the existing dam body via intake facility (water intake for agricultural use) the flying deck. (Current project) (Constructed by IHI in 1961) The movable frame of the gate leaf is a welded structure. Because of restric- tions imposed on its transportation, the Fig. 2 Overview of Selective Water Intake Facility movable frame was divided into several Flying deck Flying deck blocks, which were carried into the site and assembled by means of on-site weld-

Lifting device ing. Fig. 3 shows a three-dimensional Lifting device Flying deck drawing of the movable frame. receiving table Guiderail Flying deck Movable receiving table frame Fig. 3 Three-dimensional Drawing of Upper screen Water intake Impervious cover plate Movable Frame membrane/ Guiderail frame Guiderail frame Movable frame

Guiderail Water receiving table intake screen

Upper screen Shelter Shelter Frame receiving Shelter frame Shelter frame table Shelter Shelter receiving receiving table table (Full expansion state) (Full contraction state)

April 2018 Steel Construction Today & Tomorrow 16 Features of Lean Duplex Stainless Low Burdens on and Reduced ity of hoist and its downsizing but also Steel Expense of Civil Engineering mitigate the burden placed on dam bod- The application of duplex stainless is Structures ies and other civil engineering structures, growing worldwide. In order to incor- The structural weight of the movable in recent years SUS821L1 and SUS323L porate the attainments obtained in the frame could be reduced by about 20% by are increasingly being applied in the con- development of the new duplex stain- adopting SUS821L1 lean duplex stain- struction of gate facilities on rivers and in less steel, lean duplex stainless steel was less steel, and the lightweight structure dams. In the future, it is forecasted that the standardized in the Japanese Industrial thus attained has led to a reduction of the need will further grow for the effective Standards in 2015. Currently two steel burden placed on the existing dam body. utilization of existing infrastructures such grades, SUS821L1 and SUS323L, are Photo 3 shows the full view of the Futase as the redevelopment of existing dams, registered as lean duplex stainless steel Dam after completion of the selective measures to cope with the superannuation in the Standards. water intake facility. of existing infrastructures and measures In comparison with the conventional The development of lean duplex stain- to enhance their seismic resistance. duplex stainless steel SUS329J4L, lean less steel, SUS821L1 and SUS323L, has Given these circumstances, expecta- duplex stainless steel is manufactured by allowed it to be used as a substitute for tions are high for the use of lean du- suppressing the addition of the expensive conventional stainless steel, SUS304 and plex stainless steel, SUS821L1 and elements Ni and Mo and adding N to the SUS316, and in the installation of light- SUS323L, as structural materials that extent that it does not affect weldabili- weight dam structures as well. will contribute towards the reduction of ty. The end result thus attained for lean In the construction of gate facilities, public works expenditures on such items duplex stainless steel is the realization of because these lightweight gate leaves fa- as gate facilities and other civil engineer- high strength, which is about twice that cilitate not only a reduction of the capac- ing structures. ■ of SUS304, and economic advantages, corrosion resistance and weldability sim- Table 2 Main Compositions and Mechanical Properties of Stainless Steel ilar to those of SUS304. Table 2 shows Kind Steel grade Main compositions 0.2% offset yield Tensile strength the main composition and mechanical (mass %) strength (N/mm2) (N/mm2) properties of lean duplex stainless steel. Lean duplex SUS821L1 21Cr-2Ni-0.17N ≧400 ≧600 stainless steel ≧ ≧ Application of Lean Duplex Stain- SUS323L 23Cr-4Ni-0.15N 400 600 Duplex less Steel SUS329J4L 25Cr-7Ni-3Mo ≧450 ≧620 The gate leaf of the selective water in- stainless steel take facility constantly remains in wa- Austenitic SUS304 18Cr-8Ni ≧205 ≧520 ter. Accordingly, from the aspect of se- stainless steel SUS316L 18Cr-12Ni-2Mo ≧175 ≧480 curing corrosion resistance and reducing the lifecycle cost of the selective water intake facility, it has recently become common practice to adopt stainless steel for such an application. In order to fur- ther reduce the burden placed on the existing dam body, lean duplex stain- less steel SUS821L1 that has a strength about twice that of SUS304 and serves as a substitute for SUS304 was adopted for the movable frame of the gate leaf, which successfully led to a further reduction of the structural weight of the gate leaf. Photo 1 Factory temporary assembly of gate leaf Photo 2 Installation of gate leaf (movable frame) In adopting SUS821L1 for the mov- (movable frame) employing SUS821L1 able frame of the gate leaf, both facto- ry and on-site welding tests were carried out to confirm its weldability and the va- lidity of the welding conditions. In ad- dition, corrosion resistance tests were implemented for welds to confirm that the corrosion resistance of the welds of SUS821L1 is similar to or higher than that of SUS304. Photo 1 shows the trial assembly of gate leaf (movable frame) for which SUS821L1 is adopted, and Photo 2 the installation of gate leaf.

Photo 3 Full view of Futase Dam after completion of selective water intake facility

17 Steel Construction Today & Tomorrow April 2018 JSSC International Events PSSC2019 to Be Held in Japan The Pacific Council of Structural Steel but in recent conferences the number has by JSSC President Yozo Fujino and has Associations (PCSSA) is an organiza- increased to 11 (see the table at right). started preparations for the PSSC2019 tion in which the Japanese Society of In order to take all possible measures that is planned for November 2019 in Steel Construction and other steel con- for a successful 12th PSSC, the Japa- Tokyo. In 2020, the Tokyo Olympic and struction-related associations of the Pa- nese Society of Steel Construction es- Paralympic Games will be held. In light cific rim participate. PCSSA not only tablished the Specialized Committee for of this, PSSC2019 is expected to present serves as a site for promoting exchang- Arranging PSSC2019 which is chaired a good opportunity for the Japanese steel es among its participating organizations construction-related companies to dis- and solving common tasks but also func- Outline of Pacific Structural Steel seminate their world-class technologies tions as a nucleus for promoting the Pa- Conferences (PSSC) and for its young researchers and engi- cific Structural Steel Conference (PSSC) Year PSSC Host country neers to deepen exchanges with overseas that is hosted every three years on an al- researchers and engineers. ternating basis among the participating 1986 1st New Zealand nations. 1989 2nd Australia Eleven Organizations in Eleven The first PSSC was held in New Zea- Participating Countries 1992 3rd Japan (Tokyo) land in 1986 followed by ten subsequent • American Institute of Steel Construction PSSCs in other countries (see the table at 1995 4th Singapore (AISC) right). The previous 11th PSSC was held • Australian Institute of Steel Construction 1998 5th Korea (Seoul) (AISC) in Shanghai, China in October 2016, and • Canadian Institute of Steel Construction on that occasion with representatives 2001 6th China (Beijing) (CISC) • Chilean Steel Institute from various countries, it was decided 2004 7th USA (Long Beach) • to hold the 12th PSSC in Japan in 2019. China Steel Construction Society 2007 8th New Zealand (Taupo) • Japanese Society of Steel Construction In this connection, the ceremony to de- (JSSC) liver the PSSC flag from China to Japan 2010 9th China (Beijing) • Korean Society of Steel Construction (KSSC) was held (see the photo). The 12th con- 2013 10th Singapore • Mexican Institute of Steel Construction ference will be the first one held in Japan • Malaysian Structural Steel Association since the third one 27 years ago in 1992. 2016 11th China (Shanghai) • Steel Construction New Zealand • Singapore Structural Steel Society According to the record, the participat- 2019 12th Japan (Tokyo); Planned (SSSS) ing counties numbered seven in 1992,

Ceremony to deliver the PSSC flag from China to Japan Construction is proceeding of the New National Sta- Courtesy of JSC dium for the Tokyo 2020 Olympic and Paralympic Games (as of February 2018).

2017 China-Japan-Korea Tall Building Forum in Chongqing, China The 2017 China-Japan-Korea Tall Build- nearly 500 thereby resulting in a large- Japan, with Chairman Akira Wada of the ing Forum was held on September 21 scale international conference. CTBUH Japan Structures Committee of and 22, 2017 at The Westin Chongqing In the day-and-a-half forum, diverse the Japanese Society of Steel Construc- Liberation Square in Chongqing, China. kinds of lectures concerning tall build- tion as their representative, participat- The current forum was held jointly with ings were delivered by 28 lecturers such ed in the forum. Of these engineers, four other tall building-related symposiums as land developers, architects and struc- delivered lectures concerning the struc- under the common name of 2017 Su- tural engineers from Japan, China, Ko- tural design of seismic-isolation and re- per Tall Building Industry International rea, the US and Russia. sponse-control tall buildings and a rapid Summit. The total participants numbered A total of 12 structural engineers from (continued overleaf )

April 2018 Steel Construction Today & Tomorrow 18 diagnosis system of tall buildings during scale development project that aims to verse architecturally and structurally earthquakes to demonstrate advanced construct complex facilities (hotel, resi- unique features are incorporated in the wind- and seismic-resistant technologies dence, office and retail) with a total floor project. Currently, the building framing in the field of tall building construction area of 1.13 million m2. The project will work is proceeding with a targeted com- in Japan. include eight tall buildings composed of pletion date in 2019. More than 100 fo- In the afternoon of the second day of two north towers that are 350 m high and rum participants visited to the construc- the forum, a Technical Tour was made six south towers with a height of 250 m. tion site. to the site of Raffles City Chongqing On top of the four south towers, a 300 (Prepared by Masayoshi Nakai, Direc- that was under construction in Chao- m-long observation deck will connect tor, CTBUH Japan Structures Commit- tianmen, Chongqing. the four towers, which is seismically iso- tee of JSSC) Raffles City Chongqing is a gigantic- lated via friction pendulum bearings. Di-

Lecture delivery from Japan Raffles City Chongqing project underway

Message from International Committee Chairman Towards Further Development of Steel Construction Technologies Hiroshi Katsuchi, Chairman, International the International Committee of JSSC steel to the water intake facility of the Committee of JSSC (Professor, Yokohama was responsible for editing Issue No. 53 Futase Dam is introduced. National University) of Steel Construction Today & Tomor- Regarding our international events in The Japanese Society row, a special issue for JSSC. 2017, two reports are inserted-the es- of Steel Construction Issue No. 53 firstly introduces the tablishment of the special committee for (JSSC) has conduct- JSSC Commendations for Outstanding the 12th Pacific Structural Steel Con- ed a wide range of Achievements in 2017-JSSC Awards, ference (PSSC2019) planned for To- activities in the form Outstanding Achievement Awards and kyo, Japan in 2019, and the 2017 Chi- of surveys, research Thesis Awards. In addition, this issue na-Japan-Korea Tall Building Forum in and technological de- features outstanding Japanese steel con- Chongqing, China held in September velopment aimed at promoting the spread struction technologies utilized in over- 2017. of steel construction and at improving as- seas construction projects-Passenger Finally, we would like everyone to sociated technologies, and at the same Terminal of the New Doha International be continuously aware of the activities time it has extended cooperation to related Airport, the Taipei Nanshan Plaza proj- of JSSC and we would also like to hear overseas organizations. Aimed at spread- ect in Taiwan and the Tsubasa Bridge in your opinions at any time. ing the steel construction technologies of Cambodia. In addition, a report on the Japan to developing overseas markets, application of new lean duplex stainless

STEEL CONSTRUCTION TODAY & TOMORROW © 2018 The Japan Iron and Steel Federation Edited by Published jointly by Committee on Overseas Market Promotion, The Japan Iron and Steel Federation The Japan Iron and Steel Federation Chairman (Editor): Hiroyuki Tanaka 3-2-10, Nihonbashi Kayabacho, Chuo-ku, Tokyo 103-0025, Japan Phone: 81-3-3669-4815 Fax: 81-3-3667-0245 Published three times per year, STEEL CONSTRUCTION TODAY & URL http://www.jisf.or.jp/en/index.html TOMORROW is circulated to interested persons, companies and public organizations to promote a better understanding of steel products and their Japanese Society of Steel Construction application in the construction industry. Any part of this publication may be 3F Aminosan Kaikan Building, 3-15-8 Nihonbashi, Chuo-ku, Tokyo 103-0027, Japan reproduced with our permission. To download content (PDF format), please go Phone: 81-3-3516-2151 Fax: 81-3-3516-2152 our website at: http://www.jisf.or.jp/en/activitity/sctt/index.html. We welcome your URL http://www.jssc.or.jp/english/index.html comments about the publication and ask that you contact us at: [email protected].