Power System Fundamentals
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Boiler Analysis
The World’s Leading Laboratory Network Boiler Analysis Industry www.eurofins.co.nz Page 2 Table of Contents Introduction Page 3 Who should read this brochure? Page 3 Boiler water tests available Page 4 Feedwater Page 4 Boiler Water Page 5 Condensate Page 6 How to arrange everything Page 7 Analysis Page 7 Contact us Page 8 Cover Photo: Broken pressure gauge Page 3 Introduction Eurofins-ELS is one of New Zealand’s leading experts in the areas of: Air quality monitoring Biological fluids Boiler water Ceramicware and metal food containers Environmental water Food and Dairy Products Landfills Legionella Meat industry services Metals Potable water for councils Potable water for small communities Sample Integrity Sewage and effluent Swimming pools Trade waste The company has its origin as part of the Hutt City Council Laboratory and became a private enterprise in 1994. We grew through natural growth as well as the acquisition of local laboratories until in December 2012 we were acquired by Eurofins - the largest laboratory network in the world. Eurofins Scientific is an international life sciences company which provides a unique range of analytical testing services to clients across multiple industries. The Group is the world leader in food and pharmaceutical products testing. It is also number one in the world in the field of environmental laboratory services, and one of the global market leaders in agroscience, genomics, pharmaceutical discovery and central laboratory services. We are based in a purpose built facility of 1450 m2 at 85 Port Road, Lower Hutt. Eurofins-ELS is comprised of four separate laboratory areas – Instrumental Chemistry, General Chemistry, Biological Fluids, and Microbiology. -
Clayton-02 A2
QTY. PART NUMBER QTY. PART NUMBER QTY. PART NUMBER QTY. PART NUMBER 1 CLAYTON-UF-1-01-LH SIDE BEAM 1 CLAYTON-BR-3-01-BOILER SHELL 1 CLAYTON-RG-5-01-LH-CRANKCASE SIDE 1 CLAYTON-MP-6-31-CRANKSHAFT CHAIN SPROCKET 1 CLAYTON-UF-1-02-RH SIDE BEAM 1 CLAYTON-BR-3-02-BOILER FOUNDATION RING 1 CLAYTON-RG-5-02-RH-CRANKCASE SIDE 1 CLAYTON-MP-6-32-LUBRICATOR CRANK RING 1 CLAYTON-UF-1-03-FRONT CROSS BEAM 1 CLAYTON-BR-3-03-BOILER FIRE BOX 2 CLAYTON-RG-5-03-CRANKSHAFT BEARING HOUSING 1 CLAYTON-MP-6-33-LUBRICATOR CRANK PIN 2 CLAYTON-UF-1-04-CROSS BEAM-1 1 CLAYTON-BR-3-04-BOILER CLINKERING 2 CLAYTON-RG-5-04-CRANKSHAFT BEARING 1 CLAYTON-MP-6-34-REVERSER ENGINE CRANK 1 CLAYTON-UF-1-05-CROSS BEAM-2 5 CLAYTON-BR-3-05-BOILER BUSH TYPE-A 2 CLAYTON-RG-5-05-CRANKSHAFT BEARING CAP 1 CLAYTON-MP-6-35-REVERSER LINK ROD 2 CLAYTON-UF-1-05-CROSS BEAM-2 3 CLAYTON-BR-3-06-BOILER BUSH TYPE-B 1 CLAYTON-RG-5-06-CRANKCASE OIL FILLER BOSS 2 CLAYTON-MP-6-36-REVERSER LINK ROD END 1 CLAYTON-UF-1-06-CROSS BEAM-2 LH-MOUNTING BRACKET 4 CLAYTON-BR-3-07-BOILER MOUINTING BRACKET 1 CLAYTON-RG-5-07-CRANKCASE OIL FILLER CAP 1 CLAYTON-MP-6-37A-LUBRICATOR CRANK ARM ROD 1 CLAYTON-UF-1-07-CROSS BEAM-2 RH-MOUNTING BRACKET 1 CLAYTON-BR-3-08-BOILER DOOR HINGE BRACKET 1 CLAYTON-RG-5-08-CRANKCASE FRONT 1 CLAYTON-MP-6-37B-LUBRICATOR CRANK ARM ROD END-1 2 CLAYTON-UF-1-08-FRONT BEAM ANGLE 1 CLAYTON-BR-3-09-BOILER CLINKER DOOR 1 CLAYTON-RG-5-09-CRANKCASE BOLTING FLANGE 1 CLAYTON-MP-6-37C-LUBRICATOR CRANK ARM ROD END-2 2 CLAYTON-UF-1-09-MID BEAM SUPPORT ANGLE 1 CLAYTON-BR-3-10-BOILER CLINKER DOOR HINGE -
QUIZ: Boiler System Components
9707 Key West Avenue, Suite 100 Rockville, MD 20850 Phone: 301-740-1421 Fax: 301-990-9771 E-Mail: [email protected] Part of the recertification process is to obtain Continuing Education Units (CEUs). One way to do that is to review a technical article and complete a short quiz. Scoring an 80% or better will grant you 0.5 CEUs. You need 25 CEUs over a 5-year period to be recertified. The quiz and article are posted below. Completed tests can be faxed (301-990-9771) or mailed (9707 Key West Avenue, Suite 100, Rockville, MD 20850) to AWT. Quizzes will be scored within 2 weeks of their receipt and you will be notified of the results. Name: ______________________________________________ Company: ___________________________________________ Address: ____________________________________________ City: ______________________ State: _____ Zip: ________ Phone: ______________________ Fax: __________________ E-mail: _____________________________________________ Boiler Systems – Boiler Components By Irvin J. Cotton, Arthur Freedman Associates, Inc. and Orin Hollander, Holland Technologies, Inc. This is part two of a three-part series on boilers. In part one, the authors discussed boiler design and classification. Part two will discuss boiler components, and part three will describe the various chemistries used in boiler water treatment. Boiler Components The main components in a boiler system are the boiler feedwater heaters, deaerator, boiler, feed pump, economizer, boiler, superheater, attemperator, steam system, condenser and the condensate pump. In addition there are sets of controls to monitor water and steam flow, fuel flow, airflow and chemical treatment additions. Water sample points may exist at a number of places. Most typically the condensate, deaerator outlet, feedwater (often the economizer inlet), boiler, saturated steam and superheated steam will have sample points. -
Steam Generator Installation Manual
Cover Steam Master Steam Generator Installation Manual Clayton Industries City Of Industry, California R027949B.1 USA 06-2019 For your convenience, enter your unit’s specific model and serial number in the space below. The model and serial number are located on the right-hand side of the electronic controls cabinet. MODEL: _______________________ SERIAL NUMBER: _____________________ Title Page Steam Master Steam Generator Installation Manual CLAYTON INDUSTRIES 17477 Hurley Street City of Industry, CA 91744-5106 USA Phone: +1 (626) 435-1200 FAX: +1 (626) 435-0180 Internet: www.claytonindustries.com Email: [email protected] © Copyright 2018 Clayton Industries. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means (electronic, mechanical, photocopy, recording, or otherwise) without written permission from Clayton Industries. The descriptions and specifications shown were in effect at the time this publication was approved for printing. Clayton Industries, whose policy is one of continuous improvement, reserves the right to discontinue models at any time, or change specifications or design without notice and without incurring any obligation. FACTORY DIRECT SALES AND SERVICE UNITED STATES OFFICES ATLANTA • CHICAGO • CINCINNATI • CLEVELAND • DALLAS • DETROIT KANSAS CITY • LOS ANGELES • NEW ENGLAND • NEW JERSEY NORTHERN CALIFORNIA LICENSEES, AFFILIATES, SALES and SERVICE DISTRIBUTORS WORLDWIDE Table of Contents Section 1 Introduction ............................................................................................................... -
Nine Mile Point Nuclear Station, Units 1 and 2
May 8, 2019 Mr. Bryan C. Hanson Senior Vice President, Exelon Generation Company, Nine Mile Point Nuclear Station, LLC 4300 Winfield Road Warrenville, IL 60555 SUBJECT: NINE MILE POINT NUCLEAR STATION UNITS 1 AND 2 – INTEGRATED INSPECTION REPORT 05000220/2019001 AND 05000410/2019001 Dear Mr. Hanson: On March 31, 2019, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at your Nine Mile Point Nuclear Station Units 1 and 2. On April 25, 2019 the NRC inspectors discussed the results of this inspection with Mr. Peter Orphanos and other members of your staff. The results of this inspection are documented in the enclosed report. NRC inspectors documented three findings of very low safety significance (Green) in this report. Two of these findings involved violations of NRC requirements. The NRC is treating these violations as non-cited violations (NCVs) consistent with Section 2.3.2.a of the Enforcement Policy. If you contest the violations or significance or severity of the violations documented in this inspection report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region I; the Director, Office of Enforcement; and the NRC resident inspector at Nine Mile Point. In addition, if you disagree with a cross-cutting aspect assignment or a finding not associated with a regulatory requirement in this report, you should provide a response within 30 days of the date of this inspection report, with the basis for your disagreement, to the U.S. -
United States Patent (10) Patent No.: US 7,325.400 B2 Cunningham Et Al
USOO7325400B2 (12) United States Patent (10) Patent No.: US 7,325.400 B2 Cunningham et al. (45) Date of Patent: Feb. 5, 2008 (54) RANKINE CYCLE AND STEAM POWER 5,850,739 A 12/1998 Masnoi PLANT UTILIZING THE SAME 6,003,317. A 12/1999 Neubert 6,234,400 B1* 5/2001 Guyer ....................... 237,121 (75) Inventors: Carla I. Cunningham, Orlando, FL s: R 23: R SS MichaelA S. Briesch, Orlando, FL 6,457.95044 B1 10/2002 CooperaSSlly et al. FOREIGN PATENT DOCUMENTS (73) Assignee: Siemens Power Generation, Inc., Orlando, FL (US) DE 2 242302 3, 1974 DE 33 27 838 A1 12, 1983 (*) Notice: Subject to any disclaimer, the term of this DE 35 31 469 A1 1987 patent is extended or adjusted under 35 DE 36 16 797 A1 11, 1987 U.S.C. 154(b) by 686 days DE 195 24 216 A1 1, 1997 M YW- y yS. FR 974 116 2, 1951 GB 885643 12, 1961 JP 2002-303105 * 10/2002 (22) Filed: Jan. 9, 2004 * cited by examiner (65)65 PriorO PublicationDO Dat Primary Examiner—Hoang Nguyen US 2005/O15O227 A1 Jul. 14, 2005 (57) ABSTRACT (51) Int. Cl. FOIK I3/00 (2006.01) A steam power plant (100) implementing an improved (52) U.S. Cl. ........................................... 60/645; 60/670 Rankine cycle (55) wherein steam is injected (82, 96) (58) Field of Classification Search .................. 60/651, directly into the energy addition portion of the plant, and the 60/671, 645, 670 resulting two-phase flow is pressurized by multiphase See application file for complete search history. -
Economics of Energy Resources Lecture Notes
Philadelphia University –Jordan Electrical Engineering Department Economics of Energy Resources Lecture Notes Dr.Prof.Mohammed Tawfeeq Lazim Al-Zuhairi [email protected] 2008-2009 1 Economics of Energy Resources Dr.Mohammed Towfeeq Chapter One Economics of energy resources 1 1.1 Introduction Economics of energy resources studies energy resources and energy conversion as well as energy utilization. It includes: studies various types and sources of energy existing in the nature highlighting their features, advantages and disadvantages. The studies will emphasis on converting the available energy resources into electrical form of energy. Demand of energy is derived from preferences for energy services and depends on properties of conversion technologies and costs. Energy commodities are economic substitutes. The study also recognizes: 1) energy is neither created nor destroyed but can be converted among forms (the First Law of Thermodynamics); 2) energy comes from the physical environment and ultimately returns there (the law of conservation of energy). Economics of Energy Energy economics is the field that studies human utilization of energy resources and energy commodities and the consequences of that utilization. In physical science terminology, “energy” is the capacity for doing work, e.g., lifting, accelerating, or heating material. In economic terminology, “energy” includes all energy commodities and energy resources, commodities or resources that embody significant amounts of physical energy and thus offer the ability to perform work. Energy commodities - e.g., gasoline, diesel fuel, natural gas, propane, coal, or electricity – can be used to provide energy services for human activities, such as lighting, space heating, water heating, cooking, motives power, electronic activity and electric power generation. -
CHAPTER 6 Thermal-Hydraulic Design
1 CHAPTER 6 Thermal-Hydraulic Design Prepared by Dr. Nikola K. Popov Summary This chapter covers the thermal-hydraulic design of nuclear power plants with a focus on the primary and secondary sides of the nuclear steam supply system. This chapter covers the following topics: evolution of the reactor thermal-hydraulic system; key design requirements for the heat transport system; thermal-hydraulic design principles and margins; design details of the primary and secondary heat transport systems; fundamentals of two-phase flow; fundamentals of heat transfer and fluid flow in the reactor heat transport system; other related topics. ©UNENE, all rights reserved. For educational use only, no assumed liability. Thermal-Hydraulic Design – December 2015 2 The Essential CANDU Table of Contents 1 Introduction........................................................................................................................... 10 1.1 Overview....................................................................................................................... 10 1.2 Learning outcomes........................................................................................................ 12 1.3 Summary of relationship to other chapters ................................................................... 12 1.4 Thermal-hydraulic design ............................................................................................. 12 2 Reactor Types ...................................................................................................................... -
Circulatic Steam Generator Installation Manual
STEAM GENERATORS CIRCULATIC® STEAM GENERATORS INSTALLATION MANUAL VAPOR POWER INTERNATIONAL 551 S. County Line Rd. Franklin Park, IL 60131 P: 630.694.5500 F: 630.694.2230 VaporPower.com Revised July 2005 Bulletin No. Printed in U.S.A. TWM5-AM-2 CIRCULATIC TABLE OF CONTENTS Section Page No. List of Figures ..................................................................................................................2 List of Tables ...................................................................................................................2 1.0 Introduction .....................................................................................................................3 2.0 Lifting and Handling .........................................................................................................4 3.0 Installation .......................................................................................................................8 4.0 Mounting .........................................................................................................................9 5.0 Clearances .................................................................................................................... 10 6.0 Combustion and Ventilation Air Requirements ............................................................... 12 7.0 Stack Installation ........................................................................................................... 13 8.0 Steam Output ............................................................................................................... -
Steam Boiler Feedwater Storage Technology
www.spiraxsarco.com/uk Steam Boiler Feedwater Storage Technology Supporting an energy efficient, highly reliable steam system White Paper Steam Boiler Feedwater Storage Technology Contents 1.0 Executive Summary 2.0 The role of the deaerator in steam systems 3.0 The need to remove dissolved oxygen and other gases from feedwater 4.0 The components of an effective feedwater system 4.1 Feedtank construction 4.2 Feedtank capacity 4.3 Make-up water 4.4 Water level control 4.5 Feedtank connections 4.6 Sparge pipes 4.7 Steam injectors 5.0 Deaerator systems 5.1 Atmospheric deaerator systems 5.2 Pressurised deaerator systems 6.0 The Spirax Sarco feedwater system portfolio 7.0 Conclusion: Deaerators are critical for efficient and reliable steam systems www.spiraxsarco.com/uk 1.0 Executive Summary This paper describes best practice for boiler In practice two alternatives exist to suit a steam feedwater system design and operation for owners user’s requirements: an atmospheric solution or a and operators of boiler plant. pressurised system. The feedwater storage system, or feedtank, and A well-designed atmospheric deaerator raises the its associated components are vital for the correct feedwater temperature to approximately 85-90°C and efficient operation of the entire industrial steam to remove dissolved oxygen from the water which and condensate system. A correctly designed and would otherwise cause corrosion in the steam and implemented feedtank offers substantial savings in condensate system, and lead to rapid deterioration energy and water treatment costs, and increases of the boiler. It can also reduce the need for oxygen the reliability of the steam system for a more secure scavenging chemicals such as sodium sulphite by as steam supply. -
Hurst Boiler & Welding Company, Inc
Hurst Boiler & Welding Company, Inc. P.O. Drawer 530 - Highway 319 North Coolidge, Georgia 31738 877-99HURST – Toll Free 229-346-3545 – Local 229-346-3874 – Fax www.hurstboiler.com SERIES 45 STEAM BOILER (8.5- 813 HP, STEAM 15 psig) SAMPLE SPECIFICATIONS The following sample specifications are provided by Hurst Boiler & Welding Co., Inc. to assist you in meeting your customer's specific needs and application. The sample specifications are typically utilized as the base template for the complete boiler specification. Contact your local Hurst Boiler & Welding Co., Inc. authorized representative for information on special insurance requirements, special code requirements, optional equipment, or general assistance in completing the specification. 1.0 – General Boiler Specifications 1.1 - The Steam Boiler shall be Hurst Boiler & Welding Co., Inc. Series 45, hp designed for 15 psig. The maximum operating pressure shall be psig and the minimum operating pressure shall be psig. 1.2 - The boiler shall have a maximum output of Btu/hr, or horsepower when fired with oil and/or natural gas, Btu/cu-ft. Electrical power available shall be Volt Phase Cycle. 2.0 – Boiler Design 2.1 - The boiler shall be a three-pass wetback horizontal firebox type boiler with four (4) square feet of fireside heating surface per rated boiler horsepower. Furnace volume shall not be less than cubic feet. It shall be mounted on a heavy steel frame with integral forced draft burner and burner controls. The complete packaged boiler approved as a unit by Underwriters Laboratories and shall bear the UL label. 2.2 - The boiler shall be completely preassembled and tested at the factory. -
Description of the Advanced Gas Cooled Type of Reactor (AGR)
Nordisk Nordisk Poh|oismaincn Nordic kerne- karn- ydin- nuclear sikkerheds- sakcrhets- turvallisuus- safely forskning forskning lutkimus research KAK-2 NKS/RAK2(96)TR-C2 DK9700041 Description of the Advanced Gas Cooled Type of Reactor (AGR) Erik Nonbel Riso National Laboratory Roskilde, Denmark November 1996 Abstract The present report comprises a technical description of the Advanced Gas cooled Reactor (AGR), a reactor type which has only been built in Great Britain 14 AGR reactors have been built, located at 6 different sites and each station is supplied with twin-reactors The Torness AGR plant on the Lothian coastline of Scotland, 60 km east of Edinburgh, has been chosen as the reference plant and is described in some detail Data on the other 6 stations, Dungeness B, Hinkley Point B, Hunterston B, Hartlepool, Heysham I and Heysham II, are given only in tables with a summary of design data Where specific data for Torness AGR has not been available, corresponding data from other AGR plants has been used, primarily from Heysham II, which belongs to the same generation of AGR reactors The information presented is based on the open literature The report is written as a part of the NKS/RAK-2 subproject 3 "Reactors in Nordic Surroundings", which comprises a description of nuclear power plants neighbouring the Nordic countries NKS/RAK-2(96)TR-C2 ISBN 87-550-2264-2 Graphic Service, Riso, 1996 Tlic report can be obtained from NKS Secretariat Phone +45 46 77 40 45 POBox49 Fax +45 46 35 92 73 DK-4000 Roskildc hUp/Auuv nsoc dk/nks Denmark e-mail anncttc.lemmensfr nsoe dk -3- Contents 1 INTRODUCTION 8 2 SUMMARY OF DESIGN DATA 10 3 SITE AND REGION 13 3.1 Selection of the site 13 4 SAFETY CRITERIA 14 5 TECHNICAL DESCRIPTION AND DESIGN EVALUATION 15 5.1 Plant arrangement 15 5.2 Buildings and structures 16 5.3 Reactor core and other reactor vessel internals 17 5.3.1 Mechanical design..