CIMPLICITY 11 Important Product Information

GE Digital Proficy Historian and Operations Hub: Data Analysis in Context 1 Proprietary Notice The information contained in this publication is believed to be accurate and reliable. However, General Electric Company assumes no responsibilities for any errors, omissions or inaccuracies. Information contained in the publication is subject to change without notice. No part of this publication may be reproduced in any form, or stored in a database or retrieval system, or transmitted or distributed in any form by any means, electronic, mechanical photocopying, recording or otherwise, without the prior written permission of General Electric Company. Information contained herein is subject to change without notice.

© 2020, General Electric Company. All rights reserved.

Trademark Notices GE, the GE Monogram, and Predix are either registered trademarks or trademarks of General Electric Company. Microsoft® is a registered trademark of Microsoft Corporation, in the United States and/or other countries. All other trademarks are the property of their respective owners.

We want to hear from you. If you have any comments, questions, or suggestions about our documentation, send them to the following email address: [email protected] Important Product Information Chapter 1. Important Product Information...... 3 What's New in CIMPLICITY 11...... 3 System Requirements and Compatibility...... 4 Known Issues in CIMPLICITY 11...... 8 Fixed Defects in CIMPLICITY 11...... 9 Chapter 1. Important Product Information

What's New in CIMPLICITY 11

The HMI/SCADA CIMPLICITY v11.0 release includes the following new features and enhancements.

Component Feature Description

Alarm Setups • Text filtering (substring, wildcard, and regular expression) is now allowed on the Alarm ID, Alarm Message, and Alarm description fields. • Alarm description has been added as a Alarm viewer column. • The CIMPLICITY Alarm Viewer API contains two new classes: ◦ CAmvFieldFilter ◦ CAmvFieldFilterList

• The AlarmInfo structure for the CAmvConn class has a new member - alarm_description. • The class AMAPEXPORT CAmvConn has a new member - CAmvFieldFilterList*.

Basic Control Engine/ • In the Event Editor, when you configure an event, you can now run scripts in threads from a Scripting thread pool. • You can automatically calculate the thread pool size or set a fixed thread pool size. • When a configured event with a script action is triggered, you can choose to execute the script in sequence or in parallel.

CimEdit • For a text object, you can now choose the data entry type for the display value. ◦ Read Only Expression ◦ Read/Write Point ◦ Read/Write Variable • When configuring a CimEdit procedure, an action type has been added to evaluate an expression and assign the evaluated value to a variable. • You can now use Shape Attributes to create animations for objects at run time by configuring expression functions. • You can perform Digit Grouping to integer and real display formats to add the thousands separator to the result of an expression evaluation. • You can use text format functions, such as FormatReal and FormatInt in expressions to assign precision to real and integer point values. • You can now use the upgraded Expression Builder to create an expression using points, class data items, or Historian tags.

CIMPLICITY • CIMPLICITY supports Windows Server 2019 • CIMPLICITY works with Database configurations using SQL 2016 AlwaysOn with the exception of the Tracker Attribute Database (TADB) functionality. • The latest Specifications/Toolkits for UA Server/Client/GDS have been updated. Important Product Information | 1 - Important Product Information | 4

Component Feature Description

CIMPLICITY API tool kit CIMPLICITY supports Microsoft Visual Studio 2017. Note: Use Microsoft Visual Studio 2017 to recompile all programs that use APIs.

Database You can use the CIMPLICITY Database Logger to record a project's status log messages to the Logger COR_LOG database table in addition to the cor_recstat.cl2 file in the project’s \log directory.

Points The Change Approval UI has been enhanced to show the current value of the point being considered for change alongside the new value.

SCADA Web You can now use CIMPLICITY's SCADA Web Configuration to discover the address space of an Configuration OPC UA Server and automatically create points from the address space.

Note: Be aware of the following:

• Microsoft Access is no longer supported by CIMPLICITY. • Portal is at its end of life, and its integration with CIMPLICITY is no longer supported. Contact your sales representative for alternate solutions.

System Requirements and Compatibility

Hardware Requirements

CIMPLICITY v11.0 requires, at a minimum, the following hardware specifications. GE Digital recommends testing your particular system to determine if your performance needs require hardware beyond the base system recommendations.

Hardware Requirements

Microprocessor Intel Core 2 Duo 3.0 GHz

RAM 4 GB

Hard disk 40 GB

Ports

• USB port, if using a USB M4 or M5 license or a green key.

• Serial port for some touch screens, pointing devices, and I/O drivers

• Additional ports for I/O hardware Important Product Information | 1 - Important Product Information | 5

Hardware Requirements

Monitor

• Color graphics monitor, SVGA or better

• 24-bit graphics card capable of 800 x 600 resolution

Supported Operating Systems and Versions

CIMPLICITY v11.0 runs on any of the following operating systems, provided that specified revisions and service packs are included.

• Microsoft® Windows® 10 (32-bit or 64-bit), Professional, Enterprise & Ultimate Editions

• Microsoft® Windows® 8.1 (32-bit or 64-bit), Professional, Enterprise & Ultimate Editions

• Microsoft® Windows® Server 2019

• Microsoft® Windows® Server 2019 Cluster

• Microsoft® Windows® Server 2016

• Microsoft® Windows® Server 2016 Cluster

• Microsoft® Windows® Server 2012 R2

• Microsoft® Windows® 10 IoT Enterprise (LTSB) (Only full blown IoT version is supported. Not the core & mobile versions)

.NET Installation

NET 3.5 SP1 is required for the CIMPLICITY installer.

Supported External Software Versions

CIMPLICITY v11.0 is compatible with the following external software.

External Supported Version Software

Microsoft Office 2016 Important Product Information | 1 - Important Product Information | 6

External Supported Version Software

Microsoft SQL Server 2014, 2016, and 2017 Important: SQL Server 2008 can be installed but is no longer supported.

Note: CIMPLICITY has been validated to work with Database configurations using SQL 2016 AlwaysOn with the exception of the Tracker Attribute Database (TADB) functionality.

SQL Express 2014, 2016, and 2017

Oracle 12c

Note:

1. Oracle 12c is the only version supported by CIMPLICITY 11.0. 2. Both the client and server should be running Oracle 12c.

Microsoft Visual 2017 Studio

Flexera 2018 Software - Install Shield

Sequent - Alarm 10.01.01 Cast

Supported GE Software Versions

CIMPLICITY v11.0 is compatible with the following GE software.

Install Before or GE Software Supported Version After CIMPLICITY

Alarm Cast 10.01.01 After Administrator

Change 9.5 Before Management

Common Licensing Latest version With CIMPLICITY

Driver Server Latest version Either

Global Discovery 2.2 After Server

Historian (full Either version) 8.0, 7.2 (Latest SIM), 7.1 (Latest SIM), and 7.0 (Latest SP/SIM)

Note: Logging array points to Historian is supported from version 7.0 onwards. Important Product Information | 1 - Important Product Information | 7

Install Before or GE Software Supported Version After CIMPLICITY

IGS OPC Server Latest version Either

Machine Edition 9.5 and 9.0 Either

Plant Apps 7.0 latest Service Pack Either

Portal 3.5 SP5 Either

Proficy Driver Latest version With CIMPLICITY Server (PDS)

Web HMI/OPSHUB 2.2/1.1 Either

Webspace 6.0 & 5.0 After

Compatibility Requirements

Note the following as they apply to your installation:

Element Requirement

Network Communication Allen-Bradley Ethernet Driver I/O Note the following:

• RSLINX OEM 3.80.00 is required.

• Rockwell requires a Factory Talk activation for RSLINX OEM. If RSLINX OEM is not activated, the Allen-Bradley Ethernet device communication interface will not run. Allen-Bradley Internet is supported on the following operating systems:

Windows 2019

Windows 8.1

Windows 10

Server2012R2

Server 2016

Windows 10 IoT, LTSB

Note: Depending on the OS, some RSLINX OEM features may not be supported. Refer to the RSLINX documentation for further information. Important Product Information | 1 - Important Product Information | 8

Element Requirement

Genius PCI If you are using Genius PCI communications you need:

• One full height PCI slot for each port (up to four)

• One Genius PCI card (IC660ELB931)

Note: Genius PCI is only supported on 32-bit Windows 7 and Windows 10 systems.

Reflective Memory If you are using reflective memory, the card requirements are:

• PCPCIE-5565PIORC requires a low profile PCI Express Slot for each card

• PCI-5565PIORC requires a 64-bit PCI slot for each card

• PCIE-5565RC requires a PCI Express Slot.

Note: You can install up to two reflective memory cards, but not all computers support two cards due to hardware or BIOS-specific limitations. The Reflective Memory driver is only supported on Windows 7 and is no longer packaged with CIMPLICITY. However, the package is available from Abaco, who is also the vendor for the reflective memory cards.

You must install the following package:

RFM2G Windows 7/XP/Vista/Server 2008/Server 2003/32/64-bit PCIE/PCI/PMC Driver for X86 R08.01.

DDE Communications The DDE communications interface runs in the service session only. The DDE server must be able to run from the service session.

Browsers The following browsers are supported for WebSpace with CIMPLICITY.

66 or Greater • 41 or Greater •

The following browsers are supported with the SCADA Web Configuration:

• Google chrome 76 and above • Safari 10 and above, MacBook only (not iPad or iPhone) • Microsoft Edge on Windows 10 - 44.x • Firefox 67

Known Issues in CIMPLICITY 11 Important Product Information | 1 - Important Product Information | 9

The following issue has been identified in CIMPLICITY v11.0.

Product: SQL Server Native Client

Affected Version: SQL Server Native Client 11.0

Ticket Number: DE93978

Issue Description: Windows Defender prevents SQL Server Native Client from being installed as part of the CIMPLICITY install.

Suggested Workaround: To install SQL Server Native Client, perform either of the following actions.

• Install SQL Server Native Client before installing CIMPLICITY.

To do this: 1. In the CIMPLICITY DVD, access \Setup\Microsoft\SQLNativeClient2012. 2. Based on your 32-bit or 64-bit operating system, access the x86 or x64 folder. 3. Run the sqlncli.msi installation file.

• Turn off Windows Defender and then install CIMPLICITY.

Fixed Defects in CIMPLICITY 11

The following issues have been resolved in CIMPLICITY v11.0.

Device Communications/ PDS Configuration window access issue

DE92042

SF-00634853

Issue Reported: Previously, in a Chinese operating system, when you used the PDS driver, the Server Configuration button was not aligned properly due to which the PDS Configuration window did not open.

Resolution: This issue has been resolved.

Now, in a Chinese operating system, when you use the PDS driver, the Server Configuration button is aligned properly and the PDS Configuration window opens.

CimEdit-CimView/ VisiconX zoom issue

DE28670 Important Product Information | 1 - Important Product Information | 10

SF-00451532

Issue Reported: Previously, in a screen with VisiconX controls, if you zoomed in or zoomed out, behavioral issues occurred with the VisiconX controls.

Resolution: This issue has been resolved with the latest version of VisiconX.

Now, in a screen with VisiconX controls, if you zoom in or zoom out, no behavioral issues occur with the VisiconX controls.