Elevator Doors

Total Page:16

File Type:pdf, Size:1020Kb

Elevator Doors Special Topic: Elevator Doors Vertical Freight Door Protective Devices by Henry E. Peelle III, DM Can the United Parcel Service or slide-up-to-open counterweighted car Federal Express delivery person gates for freight elevators not intended operate a freight elevator? Under for general public use. current ASME A17.1-2007/B44-07 Current Requirements code requirements, the answer is Current ASME A17.1-2007/B44- “no.” Only the operator and persons 07 requirements for bi-parting land - authorized to transport freight can ing doors permit simultaneous or ride a freight elevator. Yet, building sequential closing. During simul - owners and tenants are increasingly taneous operation, the car gate and asking if package delivery personnel landing door close together. In con - and over-the-road truckers can trast, sequence operation requires operate their freight elevator. To the car gate to be at least two-thirds heed this call, substantive changes closed before the landing door begins in door protective requirements will to close. Continuous pressure on the appear in the next addenda to ASME closing push button is required for A17.1-2007/B44-07. This update not simultaneously closing the car gate only improves user safety, but also and landing doors. Bi-parting landing permits package deliverers, over- doors with sequence operation can the-road truckers and other adult close by either continuous pressure users not part of the general public 1 on the door-close button, by auto - to operate freight elevators. matic initiation through the operation This article begins with an over view control or dwell timer, or by momen - of existing door protective require - tary pressure on the door close but - ments for vertical freight elevator ton. Doors closed by automatic or doors and the changes approved for momentary pressure also require a inclusion in the next addenda to reopening device, advance-of-closing ASME A17.1/B44. The article then audible warning, limited average turns to detailed discussions of closing speed and a door button that, the new requirements and related upon initiation, will stop closing, or rationale. Admittedly, these new stop closing and initiate reopening. requirements are complex and tech - Current safety requirements assume nical. Before concluding, the article the presence of freight operators and overviews one approach to compli - freight handlers familiar with the ance and a corollary method of in - elevator, including door operation. Henry E. Peelle III is CEO spection. This approach demonstrates Continuous-pressure close gives the of The Peelle Co., a manu - that practical implementation is far freight-elevator operator control facturer of freight-elevator simpler than users and regulators might over the initiation, continuation and doors. Peelle holds a BS in Mechanical Engineering from anticipate. The new ASME A17.1/ cancellation of door closing. In sum, Bucknell University, an MBA B44 requirements address both verti - continuous-pressure close passes re - from University of North cal counterbalanced bi-parting and sponsibility for safe door closing to the Carolina-Charlotte and a vertical slide-up-to-open landing operator. Simply releasing the door close DM from the University of Phoenix. Address cor - doors. This article will focus on the button will initiate door reopening. respondence to: [email protected]. more prevalent and popular vertical For freight elevators with auto - bi-parting landing door coupled with matic or momentary pressure closing, 148 | WWW.ELEVATOR-WORLD.COM | October 2008 Codes & Standards trained freight operators and freight handlers understand To mitigate the risk of potential injury to this broad - the meaning of door close warnings, how to cancel door ened base of users, new requirements add detection close and how to initiate reopening. Sequence operation devices able to sense the presence of an adult user within blocks egress and warns of pending landing door closure or immediately adjacent to the closing car gate, without by placing an obstruction (i.e., the car gate) into the en - regard to the location of the door or gate. Once the user trance path before closing the bi-parting landing door. enters the plane of the car gate, detection devices prevent Contact-type reversal devices mounted on the leading closing or initiates reversal to open, if closing is under - edge of the car gate stop and initiate reopening should way. Reversal becomes independent of the actions or the closing car gate encounter an obstruction. While awareness of the user, rendering moot operator knowl - code-mandated limits on average closing speed mitigate, edge of the system and reaction time. in part, the level of imparted kinetic energy caused by im - The new code requirements, by creating zones of pact, the current code permits the obstruction to experi - detection independent of the door or gate leading edge, also reduce the probability of incidental contact resulting ence the full kinetic energy of the closing car gate before from travel inertia. A moving system with mass cannot initiating reversal 2. New Requirements for Freight stop instantaneously. Initiation of reversal of a closing Elevator Door Object Detection door or gate will cause the motor operators to reverse direction and impose braking. Factors such as gate mass In the new code requirements, the sign limiting freight and speed, electro-motive forces, friction and electrical elevators to operators and freight handlers will now read, device response time impose a delay between initiation “THIS IS A FREIGHT ELEVATOR, NOT A PASSENGER of reversal and actual physical reversal of the door or ELEVATOR, AND NOT FOR GENERAL PUBLIC USE” [Pub - gate to the open direction. lic Review Draft November 2007, A17.1a-200x, Addenda In current requirements, initiation to open may com - to A17.1-2007, Requirement 2.16.5.1.2, Capital letters in mence when the reversing device physically contacts the the original] 3. This altered signage permits use by the obstruction. These devices are typically mechanical and non-trained adult user. However, this requirement still require the force of contact to signal the presence of an prohibits use of freight elevators by the general public. obstruction. Reversal systems employing a single infrared These new requirements open freight-elevator use to pack - age delivery personnel and other non-employee freigh t beam located just below the leading edge of the car gate handlers, while excluding the general building tenant, eliminate the necessity for physical contact to initiate re - visitor, passersby, child or other members of the public. versal. However, even this arrangement holds a probabil - The new ASME A17.1/B44 door protective require - ity that inertia of the closing car gate will carry the car gate ments remove the assumption of a vigilant and aware leading edge into the obstruction located just below the freight elevator operator. Unlike trained operators, pack - leading edge, albeit at a much lower level of kinetic energy. age delivery persons might have limited understanding In contrast, new code requirements impose immediate of freight elevator operation and functionality. Package initiation of reversal to the open direction as soon as a delivery persons might not attend to persons entering or person places his or her body part in a zone of detection, leaving the freight elevator when he or she is closing the regardless of the relative location of the body part to the doors. Package delivery personnel might not understand door or gate. Entry of a body part into the detection zone the meaning of advance-of-door-close warning, nor, in will prevent the fully open door or gate from closing or high ambient noise environments, hear such warnings. initiate reversal to open if the car gate is closing. A per - Package delivery persons might be unaware that action son placing his or her head into a detection zone will on the door push buttons can initiate reopening. More - initiate reversal of a closing landing door or car gate, even over, package delivery personnel might not react with if the leading edge of the door or gate is at a distance well sufficient speed, even if aware of persons within the above that person’s head. opening, while door closing is in process. While these new requirements do not eliminate the In sum, extending usage of freight elevators to pack - potential of incidental contact caused by inertia, inci - age delivery personnel limits the effectiveness of many dental contact will only result if the person intentionally traditional safety devices employed on freight elevators, places his or her body in a position immediately adjacent such as continuous pressure close and advance-of-close to the leading edge of an already closing car gate. No warnings. Moreover, current code requirements permit - longer will the reversal system wait until the leading edge ting contact-type reopening devices leave the unaware approaches or makes contact with the obstruction. Instead , and untrained user vulnerable to the full kinetic energy of reversal to open will occur upon detection of an object in the closing car gate. the detection zone, regardless of door or gate location. Continued October 2008 | ELEVATOR WORLD | 149 Special Topic: Elevator Doors Continued With impact mitigation dependent on detection devices, table provides a comparison of current and new require - new code requirements incorporate detection device func - ments for freight elevators with bi-parting landing doors. tion checking prior to closing. Should function testing fail, Detection Zones the landing door and car gate will not close. During each The new requirements describe object sizes and detec - open-close cycle, function testing validates wiring tion zones, instead of proscribing the characteristics of between the light curtain and the operational control, the detection device. While this approach added consid - light-curtain output relay, light-curtain internal control erable complexity to the new requirements, proscriptive and light-curtain transmitting and receiving elements.
Recommended publications
  • Home Elevators
    Home Elevators Live in your home with comfort and style Why a residential elevator Make your life more comfortable with a Garaventa Lift Solution • Comfortably overcome any barriers and tiring stairs. Reduce heavy lifting when transporting storage, • laundry or groceries. • An investment for your future accessibilty needs. • Choose from a variety of materials and finishes to fit your style and taste. • Our elevators are easy to install, especially in existing buildings. • Make daily routines easier! • A Garaventa Home Elevator will quickly become part of everyday life. 2 Why Garaventa Lift Garaventa Lift has been moving people since 1928. Our products have always stood the test of time. We began by building ropeways in the Swiss Alps. Garaventa Lift has since become a global organization, representing reliability, safety, and innovation. For over 90 years we have been designing the best mobility solutions for people to make every move comfortable and safe. Our secret? Customer proximity all the way, from the choice of the home elevator to after installation. Consultation Design Installation Servicing 3 Bring efficiency to your home Add value to your home A Garaventa Lift Home Elevator significantly increases the value of your house while other accessibility solu- tions can decrease the resale value. Compared to the costs of moving, a home elevator is a small investment that gives you and your family the peace of mind for now and for your future. Few steps in simplicity Comfortably overcome the few entrance steps and, why not, bring in the shopping bags too. Your guests will be impressed by the style and will appreciate the comfort and ease that a Garaventa Lift Home Eleva- tor brings to your home.
    [Show full text]
  • Safety Barrier Guidelines for Residential Pools Preventing Child Drownings
    Safety Barrier Guidelines for Residential Pools Preventing Child Drownings U.S. Consumer Product Safety Commission This document is in the public domain. Therefore it may be reproduced, in part or in whole, without permission by an individual or organization. However, if it is reproduced, the Commission would appreciate attribution and knowing how it is used. For further information, write: U.S. Consumer Product Safety Commission Office of Communications 4330 East West Highway Bethesda, Md. 20814 www.cpsc.gov CPSC is charged with protecting the public from unreasonable risks of injury or death associated with the use of the thousands of consumer products under the agency’s jurisdiction. Many communities have enacted safety regulations for barriers at resi- dential swimming pools—in ground and above ground. In addition to following these laws, parents who own pools can take their own precau- tions to reduce the chances of their youngsters accessing the family or neighbors’ pools or spas without supervision. This booklet provides tips for creating and maintaining effective barriers to pools and spas. Each year, thousands of American families suffer swimming pool trage- dies—drownings and near-drownings of young children. The majority of deaths and injuries in pools and spas involve young children ages 1 to 3 and occur in residential settings. These tragedies are preventable. This U.S. Consumer Product Safety Commission (CPSC) booklet offers guidelines for pool barriers that can help prevent most submersion incidents involving young children. This handbook is designed for use by owners, purchasers, and builders of residential pools, spas, and hot tubs. The swimming pool barrier guidelines are not a CPSC standard, nor are they mandatory requirements.
    [Show full text]
  • Installing Alley-Gates
    INSTALLING ALLEY-GATES: PRACTICAL LESSONS FROM BURGLARY PREVENTION PROJECTS Briefing Note 2/01 Shane Johnson and Camille Loxley July 2001 “The views expressed in this briefing note are those of the authors, not necessarily those of the Home Office (nor do they reflect Government policy).” Introduction Benefits of an alley-gate Alley-gating, the installation of security gates across Reducing burglary footpath and alleyways, is a form of situational crime Results from the 1998 British Crime Survey1 showed prevention that attempts to reduce the opportunity to that 55% of burglaries with entry occurred through the commit crimes such as domestic burglary. When rear in terraced and detached/semi-detached houses. installed and properly used, alley-gates should control Moreover, an analysis of recorded crime data for the access to vulnerable target areas – usually paths or county of Merseyside shows that this pattern is alleys at the rear and to the sides of houses. Although particularly evident for terraced housing, with entry there are good reasons for thinking that alley-gates being gained via the rear of the property for around 72% should reduce burglary, there is as yet little hard of burglaries. The implication of such findings is that in evidence that they do. This will be available later in the theory, by restricting access to the rear of properties, year when evaluations of projects funded by the Crime alley-gating should have a very significant effect on Reduction Programme report their findings. In the burglary, although there are as yet no impact interim, however, the promise of alley-gating is enough evaluations of alley-gating schemes available.
    [Show full text]
  • 2019-20 Carrier Dome Basketball Season Parking
    Game Day Parking Available in UAG, Manley and Skytop * PARKING AREAS TO 2019-20 MAIN NORTH CAMPUS LANCASTER AVE. Area A - $350 AVE. COMSTOCK Carrier MANLEY Area B - $335 (MANN) Dome Area C - $285 Basketball MANLEY Area D - $210 TO RT. 81 FIELD HOUSE SOUTH Season ADA $210-$350 MANLEY RT. 81 (MANS) Unavailable due EAST COLVIN ST. Parking to construction. EXIT ONLY SELECTED BUILDING ARE SHOWN ADA ACCESS SOUTH 18 MAP IS NOT TO SCALE GUARD BOOTH CAMPUS BARRIER LYM is a“Split” lot: patrons ONE WAY PARKING must park in Manley Lots for SUBJECT TO CHANGE SKYTOP RD. weekday ACC/Premium games when school in session.) SKYTOP HAR HARRISON ST. HARRISON ST. SKYTOP UNIVERSITY AVE. UNIVERSITY WALNUT PLACE WALNUT (SKYD) WALNUT AVE. WALNUT IRVING AVE. IRVING UNVN SKYTOP UNVS (SKY) UAG FROM JAMESVILLE AVE. ADAMS ST. (Garage) * Sold for major basketball Marshall SOUTH CROUSE AVE. Square games. Mall UPSTATE UNIVERSITY OSTROM AVE. ALMOND ST. MARSHALL ST. HOSPITAL MARSHALL ST. MARSHALL ST. SHERATON/ EXIT AVE. IRVING UNIVERSITY CAG 18 CROUSE HOTEL WAV (Garage) HOSPITAL N WAVERLY AVE. WAVERLY AVE. WAVERLY AVE. E W Student Bird Newhouse Complex Center - Library UPSTATE Bookstore S MEDICAL CHH UNIVERSITY PLACE UNIVERSITY Promenade Walkway Bus Entry ONLY UNIVERSITY PL. Limo/Limo Bus (max 32 seats) Dropoff and Pickup HILL CROUSE DRIVE SYRACUSE Crouse LYM College HL Smith Lyman COMSTOCK AVE. VA MEDICAL Machinery Tolley CENTER HBC Hinds COLLEGE PLACE Life Falk Sciences College Eggers and Manley- Sci Tech A QUAD L Brewster-Boland SYRACUSE Building M Skytop RT. 81 RT. O BBG Garage ND UNIVERSITY shuttle ST.
    [Show full text]
  • 1. Main Gate (Box Shape) A) Size C) Ornament
    Aadirang Mahotsav 2018, Goa May, 2018. Ambiance design and other designs, size Quantity and material details. 1. Main Gate (Box Shape) A) Size a. Top of gate box – 2- Qty. i. Upper box bottom size – 6 X 2 X 4 ( Ft ) ii. Upper box top - 8 X 2 ( Ft ) b. Top of gate box – 2 Qty. i. Lower box bottom size – 20 X 2 X 3 ( Ft ) ii. Lower box top – 24 X 2 (Ft ) c. Pillar – 4 Qty. i. Pillar size – 3 X 2 X 10 ( Ft ) ii. Pillar base size – 2’.6” X 3’.6” X 2’.6” ( Ft ) B) Quantity - 02 (Two) C) Ornament a. Bamboo Peacock Peace – 6X8X6” (Ft) – 2 Qty. b. Three festival colour Tree - 6 Qty. c. Half Peacock Peace – 3X6X6” – 4 Qty. d. 3D Piller Carving Work In MDF e. Flower Decoration on the gate. f. Border frame for whole gate g. 3D art work on piller h. Carving work in MDF i. 2 NSD logo ii. Title of festival iii. Organisers name. D) Material a. Solid Basic metal structure b. Water Proof Ply c. Art work with Bamboo d. POP, wood, metal & Sea Sand. 2. Mini Gate (Box Shape) A) Size a. Top of Gate Box – 1 i. Upper Box Bottom size – 3 X 18 inch X3 ( Ft ) ii. Upper box top size – 5 X 18 inch ( Ft ) b. Top of gate box – 2 i. Lower box bottom size – 12 X 2 X 2.6 (Ft ) ii. Lower Box Top Size – 15 X 2 X 2.6 (Ft ) c. Pillar – 4 Qty.
    [Show full text]
  • SPECIFICATIONS Freight Doors • Car Gates • Car Enclosures
    ONE COMPANY So Many Options SPECIFICATIONS Freight Doors • Car Gates • Car Enclosures Opening Quality Doors Around The World To Order Call: 1-800-533-5760 or 1-314-533-5700 Specifications FREIGHT ELEVATOR DOOR SPECIFICATIONS (Standardized ) 1.00 QUALITY ASSURANCE A. Compliance with Regulatory Agencies: All freight elevator door and car gate equipment must comply with the most stringent applicable provisions of the latest edition of the ASME A. 17.1 Safety Code for Elevators and Escalators. B. Approved Providers for vertical bi-parting freight elevator doors: Courion and Peelle. 2.00 FREIGHT ELEVATOR HOISTWAY DOOR SUMMARY Provide complete vertical bi-parting freight elevator hoistway doors at each open landing entrance consisting of manufacturer’s standard hoistway door system. Provide one (1) ver- tical slide-up counterweighted car gate at each entrance on the car as required. All freight elevator door and car gate equipment shall meet the NEMA 1, 4, 12 & 13 standards. Type Freight Elevator Capacity (lbs) Class Travel in Feet Number of Stops # of Front Openings # of Rear Openings Platform Size _____ (wide) x _____ (deep) Car Clear Inside _____ (wide) x _____ (deep) _____ x (high) Hoistway Door Type Power Operated Vertical Bi-Parting Freight Doors Hoistway Door Size _____ (wide) x _____ (high) Power Supply 208 volt, 3-phase, 60 Hz (minimum) 2 ver. 04.2008 OPENING QUALITY Doo RS AR O UN D THE WO RL D To Fax Order: 1-314-533-5720 Specifications 3.00 FREIGHT ELEVATOR HOISTWAY DOORS AND CAR GATE MATERIALS A. Hoistway Doors: Hoistway doors shall be of the vertical bi-parting (including, when re- quired, bypass bi-parting) type, counterbalanced, and power operated.
    [Show full text]
  • Universal Gate Kit
    UNIVERSAL GATE KIT The Universal Gate Kit is a convenient way to add a premium gate to your railing system. Consult your local building codes for gate requirements Important Information The Universal Gate Kit is designed to work with RadianceRail®, Premier®, and Trademark™ only. • The maximum width of a gate built with a Gate Kit is 48”. • Gates should always swing away from the stairs when opening. • Be sure to install on a post that is plumb; this is critical for the gate to operate properly. • Installation is easiest with two people. • Gate should be installed with Composite Balusters only. Component Dimensions Components Needed For Installing One Gate with the Universal Gate Kit Rail Pack 1 - Top Rail 1 - Bottom Rail 2 - Support Rails T-20 Torx driver bit Rail Pack *Additional items are included, but are not needed Baluster Pack Square Balusters Baluster Screw Kit-8’ Kits 18 in 8’ Kits 18 - #8x2” Coated Screws Baluster Screw Kit 18 - #8x3” Coated Screws RadianceRail Gate Kit 2 - Aluminum Side Rails (Brackets Attached) 2 - 4” Black Butt Hinges Aluminum Side Rails Assorted Screws Gate Latch & Stop Butt Hinges 1 - Gate Latch and Stop 8 - 1/4” x 1” Self-Drilling Flat Head Screws (black) 10 - 1/4” x 2” Flat Head Screws (black) Tools Required Tools Recommended 2 - 3/16” x 3/4” Self-Drilling Screws (black) • Miter Saw (blade designed • Ratchet 4 - 1/4” x 1” Screws (frame color) for finish cuts) 2 - 1/4” x 1-3/4” Screws (frame color) • Drill • Level • Tape Measure • 7/64” and 11/64” drill bits • #2 Phillips Driver Bit Top Rail Support Rail Screws Gate Latch Aluminum Side Rails Baluster Black Butt Hinges Aluminum Side Rails Bottom Rail Support Rail UNIVERSAL GATE KIT Two cautions to be taken to prevent a sagging gate 1 When hinge post is not supported by a parallel rail, extra caution must be taken to sturdy the post to support the Parallel Hinge Latch weight of the gate.
    [Show full text]
  • FM702 Installation Manual
    Installation Manual for the ® E-Z GATE OPENER Automatic Gate Opener System FOR DUAL SWING GATES WARNING! This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so GTO, Inc. shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter. The installer and/or user agree to assume responsibility for all liability and use of this product releasing GTO, Inc. from any and all liability. If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value. READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to install and use this automatic gate opener. This gate opener produces a high level of force. Stay clear of the unit while it is operating and exercise caution at all times. All automatic gate openers are intended for use on vehicular gates only. This product meets and exceeds the requirements of UL 325, the standard which regulates gate opener safety, as established and made effective March 1, 2000, by Underwriters Laboratories Inc.
    [Show full text]
  • Fences, Walls and Gates
    Fences, Walls and Gates Subsections: 9103.05.010 Purpose and Intent 9103.05.020 Permit Requirements 9103.05.030 Development Standards 9103.05.040 Prohibited Fencing Materials in All Zones 9103.05.010 Purpose and Intent A. This Section establishes standards and regulations for the construction and maintenance of fences, walls, and gates, as the terms are defined in Division 9 (Definitions). The standards are intended to ensure that these types of structures provide the desired privacy and safety while avoiding becoming a public safety hazard or nuisance. B. For Specific Plans and Planned Developments, fence and wall heights shall comply with the standards contained within the applicable Specific Plan or Planned Development. Where the Specific Plan or Planned Development is silent with regard to fence and wall height, the standards for the zone that most closely reflects the Specific Plan or the Planned Development shall apply, as determined by the Director. 9103.05.020 Permit Requirements Construction of new fences, walls, and gates shall be subject to Site Plan and Design Review according to Section 9107.19 (Site Plan and Design Review). 9103.05.030 Development Standards A. General 1. The fence or wall height shall be measured from the lowest adjacent grade to the uppermost part of the fence or wall. Refer to Figure 3-7 (Fence Height Measurement). 2. When there is a full landscaped parkway with no sidewalk, a fence and/or columns, excluding vehicular entry gate(s), may be placed adjacent to the front property line. 3. The need for any retaining walls and/or fences, and their heights, shall be determined by the Director and the Building Official through the Site Plan Review process.
    [Show full text]
  • THE HUMAN DESIGN SYSTEM the Complete Rave I'ching
    THE HUMAN DESIGN SYSTEM The Complete Rave I’Ching Positions Gates Themes Crosses Lines Commentaries Ra Uru Hu Jovian Archive Corporation The Complete Rave I’Ching written and compiled by Ra Uru Hu. Techni- cal support and programming by Erik Memmert. Portions of this text were adapted from The Human Design System 1992 and from from The Book of Letters 1994 by Ra Uru Hu. The Human Design System and the Global Incarnation Index are protected by Copyright. Protected under the Berne Convention. All Rights Reserved. © Copyright Jovian Archive Corporation 2001. English Edition Printed in the United States and Great Britain. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language or com- puter language in whole or in part, in any form or by any means, whether it be electronic, mechanical, magnetic, optical, manual or otherwise without the prior consent of Jovian Archive Corporation. Jovian Archive Corporation www.jovianarchive.com [email protected] Forward August 3, 2001 Diessen am Ammersee, Germany In 2000 after 13 years of introducing the Human Design Sys- tem, it was time to focus on international standards for edu- cation. The first step was to respect the needs of the student. When I returned to Europe in 2000, I began immediately to work on this edition of the Rave I’Ching with Erik Memmert. Erik’s programming skills have made the uniform lay- out/translation process translator friendly. This English edition will be followed by German, Italian and Spanish editions. The Complete Rave I’Ching is just that; a complete reference work for Human Design students and professionals alike.
    [Show full text]
  • Hardware & Supply
    Catalog 12 HaRDWaRE & SUPPlY IMS ORNAMENTAL STEEL 1425 English Street NW Atlanta, GA 30318 Toll Free Number: (800) 833-9175 Phone Number: (404) 577-5005 Fax Number: (404) 419-3490 Email: [email protected] www.imsornamental.com Stocking a Complete Line of • Gate Hardware CONTENTS • Ornamental Metal 1 - 3 Aluminum Castings • Paints • Welding & Shop Supplies 4 - 22 Decorative Metal Bars | Finials 23 - 26 Shoes, Bases & Collars Decorative Metal Elements Convenient Will Call 27 - 33 Location to Serve You 34 - 84 Scrolls | Panels | Balusters | Posts 85 - 120 Gate & Door Hardware | Hinges | Fasteners 121 - 130 Brackets, Fittings & Channel | Stair Components 131 - 149 Cast Iron 150 - 151 Power Tools 152 - 166 Welding Supplies 167 - 171 Abrasives | Drilling Accessories 172 - 176 Clamp & Vice | Measuring Tools 177 - 180 Hand Tools | Misc Shop Supplies 181 - 185 Paint & Supplies 186 - 190 Index Alumium Ornamental Castings Picket Castings (WITH STEEL WELDING TABS) FITS 1/2” PICKETS H. 16-7/8” H. 14-5/8” W. 7-3/4” H. 13-1/4” H. 14-1/2” H. 13-3/4” W. 6-7/8” WT. 0.75 lbs. W. 7-1/4” W. 7-3/4” W. 7-1/4” WT. 0.75 lbs. For 1/2” picket For 3/4” picket WT. 0.75 lbs. WT. 0.75 lbs. WT. 0.75 lbs. Single Faced Single Faced Single Faced Single Faced Single Faced Single Faced ITEM# ITEM# ITEM# ITEM# ITEM# ITEM# AC1 AC2 AC234 AC3 AC4 AC5 H. 3-3/4” W. 3-3/4” WT. 0.25 lbs. Single Faced ITEM# H. 11-7/8” H.
    [Show full text]
  • Parent and Student Handbook 2020-2021
    GATE CITY CHARTER ACADEMY 123 Flemingfield Road Greensboro, NC 27405 Phone: 336-617-5900 Parent and Student Handbook 2020-2021 A charter school managed by National Heritage Academies, Inc. Gate City Charter Academy Parent and Student Handbook 2020-2021 Parent and Student Handbook Table of Contents Board of Directors and Administrative Staff ......................................................... 6 Our Purpose, Vision, and Philosophy .................................................................. 7 The Four Pillars of NHA Academic Excellence .................................................................................... 9 Moral Focus ............................................................................................... 9 Student Responsibility .................................................................................. 9 Parental Partnership .................................................................................... 9 Academic Excellence Curriculum ................................................................................................ 10 English Language Arts ............................................................................... 10 Mathematics .......................................................................................... 10 Science ................................................................................................ 10 Social Studies ........................................................................................ 10 Art ....................................................................................................
    [Show full text]